Shakhova M, Elagin V, Plekhanov A, Khilov A, Kurakina D, Kamensky V, Kirillin M. Post-Operational Photodynamic Therapy of the Tumor Bed: Comparative Analysis for Cold Knife and Laser Scalpel Resection. Biomedicines 2024; 12:291. [PMID: 38397893 PMCID: PMC11154242 DOI: 10.3390/biomedicines12020291] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2023] [Revised: 01/17/2024] [Accepted: 01/22/2024] [Indexed: 02/25/2024] Open
Abstract
In this paper, we report on a study regarding the efficiency of the post-operational phototherapy of the tumor bed after resection with both a cold knife and a laser scalpel in laboratory mice with CT-26 tumors. Post-operational processing included photodynamic therapy (PDT) with a topically applied chlorin-based photosensitizer (PS), performed at wavelengths of 405 or 660 nm, with a total dose of 150 J/cm2. The selected design of the tumor model yielded zero recurrence in the laser scalpel group and 92% recurrence in the cold knife group without post-processing, confirming the efficiency of the laser scalpel in oncology against the cold knife. The application of PDT after the cold knife resection decreased the recurrence rate to 70% and 42% for the 405 nm and 660 nm procedures, respectively. On the other hand, the application of PDT after the laser scalpel resection induced recurrence rates of 18% and 30%, respectively, for the considered PDT performance wavelengths. The control of the penetration of PS into the tumor bed by fluorescence confocal microscopy indicated the deeper penetration of PS in the case of the cold knife, which presumably provided deeper PDT action, while the low-dose light exposure of deeper tissues without PS, presumably, stimulated tumor recurrence, which was also confirmed by the differences in the recurrence rate in the 405 and 660 nm groups. Irradiation-only light exposures, in all cases, demonstrated higher recurrence rates compared to the corresponding PDT cases. Thus, the PDT processing of the tumor bed after resection could only be recommended for the cold knife treatment and not for the laser scalpel resection, where it could induce tumor recurrence.
Collapse
Affiliation(s)
- Maria Shakhova
- Department of Ear, Nose and Throat Diseases, FSBEI HE «Privolzhsky Research Medical University» MOH Russia, 10/1 Minin and Pozharsky Square, Nizhny Novgorod 603005, Russia;
| | - Vadim Elagin
- Institute of Experimental Oncology and Biomedical Technologies, FSBEI HE «Privolzhsky Research Medical University» MOH Russia, 10/1 Minin and Pozharsky Square, Nizhny Novgorod 603005, Russia; (A.P.); (V.K.)
| | - Anton Plekhanov
- Institute of Experimental Oncology and Biomedical Technologies, FSBEI HE «Privolzhsky Research Medical University» MOH Russia, 10/1 Minin and Pozharsky Square, Nizhny Novgorod 603005, Russia; (A.P.); (V.K.)
| | - Aleksandr Khilov
- A.V. Gaponov-Grekhov Institute of Applied Physics of the Russian Academy of Sciences, 46 Ulyanov St., Nizhny Novgorod 603155, Russia; (A.K.); (D.K.); (M.K.)
| | - Daria Kurakina
- A.V. Gaponov-Grekhov Institute of Applied Physics of the Russian Academy of Sciences, 46 Ulyanov St., Nizhny Novgorod 603155, Russia; (A.K.); (D.K.); (M.K.)
| | - Vladislav Kamensky
- Institute of Experimental Oncology and Biomedical Technologies, FSBEI HE «Privolzhsky Research Medical University» MOH Russia, 10/1 Minin and Pozharsky Square, Nizhny Novgorod 603005, Russia; (A.P.); (V.K.)
- A.V. Gaponov-Grekhov Institute of Applied Physics of the Russian Academy of Sciences, 46 Ulyanov St., Nizhny Novgorod 603155, Russia; (A.K.); (D.K.); (M.K.)
| | - Mikhail Kirillin
- A.V. Gaponov-Grekhov Institute of Applied Physics of the Russian Academy of Sciences, 46 Ulyanov St., Nizhny Novgorod 603155, Russia; (A.K.); (D.K.); (M.K.)
| |
Collapse
|
2
|
Hasan MZ, Saha PS, Korfhage MO, Zhu C. Non-contact optical spectroscopy for tumor-sensitive diffuse reflectance and fluorescence measurements on murine subcutaneous tissue models: Monte Carlo modeling and experimental validations. BIOMEDICAL OPTICS EXPRESS 2023; 14:5418-5439. [PMID: 37854556 PMCID: PMC10581788 DOI: 10.1364/boe.502778] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/08/2023] [Revised: 09/12/2023] [Accepted: 09/16/2023] [Indexed: 10/20/2023]
Abstract
Fiber-optic probes are commonly used in biomedical optical spectroscopy platforms for light delivery and collection. At the same time, it was reported that the inconsistent probe-sample contact could induce significant distortions in measured optical signals, which consequently cause large analysis errors. To address this challenge, non-contact optical spectroscopy has been explored for tissue characterizations. However, existing non-contact optical spectroscopy platforms primarily focused on diffuse reflectance measurements and may still use a fiber probe in which the probe was imaged onto the tissue surface using a lens, which serves as a non-contact probe for the measurements. Here, we report a fiber-probe-free, dark-field-based, non-contact optical spectroscopy for both diffuse reflectance and fluorescence measurements on turbid medium and tissues. To optimize the system design, we developed a novel Monte Carlo method to simulate such a non-contact setup for both diffuse reflectance and fluorescence measurements on murine subcutaneous tissue models with a spherical tumor-like target. We performed Monte Carlo simulations to identify the most tumor-sensitive configurations, from which we found that both the depth of the light focal point in tissue and the lens numerical aperture would dramatically affect the system's tumor detection sensitivity. We then conducted tissue-mimicking phantom studies to solidify these findings. Our reported Monte Carlo technique can be a useful computational tool for designing non-contact optical spectroscopy systems. Our non-contact optical setup and experimental findings will potentially offer a new approach for sensitive optical monitoring of tumor physiology in biological models using a non-contact optical spectroscopy platform to advance cancer research.
Collapse
Affiliation(s)
- Md Zahid Hasan
- Department of Biomedical Engineering, University of Kentucky, Lexington, KY 40506, USA
| | - Pranto Soumik Saha
- Department of Biomedical Engineering, University of Kentucky, Lexington, KY 40506, USA
| | - Madison O. Korfhage
- Department of Biomedical Engineering, University of Kentucky, Lexington, KY 40506, USA
| | - Caigang Zhu
- Department of Biomedical Engineering, University of Kentucky, Lexington, KY 40506, USA
| |
Collapse
|
3
|
Colas V, Amouroux M, Perrin-Mozet C, Daul C, Blondel W. Photometric and Monte-Carlo modeling unified approach for the calculation of spatially-resolved correction coefficients linking simulated and experimental diffuse reflectance spectra. OPTICS EXPRESS 2023; 31:25954-25969. [PMID: 37710468 DOI: 10.1364/oe.491921] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Accepted: 06/10/2023] [Indexed: 09/16/2023]
Abstract
The estimation of skin optical properties by means of inverse problem solving from spatially resolved diffuse reflectance (SR-DR) spectra is one way to exploit the acquired clinical signals. This method requires the comparison between the experimental spectra collected with a medical device, and spectra generated by the photons transport numerical simulations. This comparison is usually limited to spectral shape due to the absence of intensity standardization of the experimental DR spectra. This study proposes to theoretically (using photometric calculation) and experimentally (from experimental spectra acquired on optical phantom) establish a corrective factor to obtain common intensity unit for experimental and simulated signals.
Collapse
|
4
|
Hasan MZ, Yan J, Yi Z, Korfhage MO, Tong S, Zhu C. Low-cost compact optical spectroscopy and novel spectroscopic algorithm for point-of-care real-time monitoring of nanoparticle delivery in biological tissue models. IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS : A PUBLICATION OF THE IEEE LASERS AND ELECTRO-OPTICS SOCIETY 2023; 29:7100208. [PMID: 36341280 PMCID: PMC9635618 DOI: 10.1109/jstqe.2022.3205862] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
OBJECTIVE Real-time monitoring of nanoparticle delivery in biological models is essential to optimize nanoparticle-mediated therapies. However, few techniques are available for convenient real-time monitoring of nanoparticle concentrations in tissue samples. This work reported novel optical spectroscopic approaches for low-cost point-of-care real-time quantification of nanoparticle concentrations in biological tissue samples. METHODS Fiber probe measured diffuse reflectance can be described with a simple analytical model by introducing an explicit dependence on the reduced scattering coefficient. Relying on this, the changes on the inverse of diffuse reflectance are proportional to absorption change when the scattering perturbation is negligible. We developed this model with proper wavelength pairs and implemented it with both a standard optical spectroscopy platform and a low-cost compact spectroscopy device for near real-time quantification of nanoparticle concentrations in biological tissue models. RESULTS Both tissue-mimicking phantom and ex vivo tissue sample studies showed that our optical spectroscopic techniques could quantify nanoparticle concentrations in near real-time with high accuracies (less than 5% error) using only a pair of narrow wavelengths (530 nm and 630 nm). CONCLUSION Novel low-cost point-of-care optical spectroscopic techniques were demonstrated for rapid accurate quantification of nanoparticle concentrations in tissue-mimicking medium and ex vivo tissue samples using optical signals measured at a pair of narrow wavelengths. SIGNIFICANCE Our methods will potentially facilitate real-time monitoring of nanoparticle delivery in biological models using low-cost point-of-care optical spectroscopy platforms, which will significantly advance nanomedicine in cancer research.
Collapse
Affiliation(s)
- Md Zahid Hasan
- Department of Biomedical Engineering, University of Kentucky, Lexington, KY 40506, USA
| | - Jing Yan
- Department of Biomedical Engineering, University of Kentucky, Lexington, KY 40506, USA
| | - Zhongchao Yi
- Department of Biomedical Engineering, University of Kentucky, Lexington, KY 40506, USA
| | - Madison O Korfhage
- Department of Biomedical Engineering, University of Kentucky, Lexington, KY 40506, USA
| | - Sheng Tong
- Department of Biomedical Engineering, University of Kentucky, Lexington, KY 40506, USA
| | - Caigang Zhu
- Department of Biomedical Engineering, University of Kentucky, Lexington, KY 40506, USA
| |
Collapse
|
5
|
Bullard EA, Mundo AI, Bess SN, Priest KM, Muldoon TJ. Minimally invasive in vivo endoscopic monitoring of dextran sulfate sodium-induced murine colitis. MethodsX 2022; 9:101744. [PMID: 35692732 PMCID: PMC9178474 DOI: 10.1016/j.mex.2022.101744] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2021] [Accepted: 05/23/2022] [Indexed: 11/15/2022] Open
Abstract
Ulcerative colitis (UC) is a gastrointestinal, autoimmune disease that causes ulceration and inflammation of the colon with an incidence of 10 out of every 100,000 people in North America and Western Europe. Though the specific cause is unknown, several studies have demonstrated that inflammatory cells as well as environmental variables, genetics, and lifestyle behaviors can play a role in the long-term inflammatory response. Researchers have commonly used immunohistochemistry, western blotting and gene sequencing to establish the cellular processes behind UC relapse and remission. However, because these destructive methods necessitate the removal of a sample, they can only be used on non-living tissues. The use of minimally invasive approaches to evaluate the in vivo, longitudinal effects of UC on the mucosa in the colon is gaining popularity among clinicians and researchers. We have created a dextran sulfate sodium-induced model of UC in C57 mice based on the work of Wirtz et al., and a minimally invasive imaging modality to explore the changes in mucosal tissue during "active" and "in remission" UC. Briefly, C57 mice were given dextran sulfate sodium (DSS) dissolved in water in 5-day cycles with a remission/recovery period of 10 days. After 7 days post-DSS treatment and 7 days post-recovery, mice were anesthetized and exploratory endoscopies were performed to assess the mucosal changes that occur during the "active" and "remission" periods of UC. Value of protocol:•Minimally invasive induction of ulcerative colitis in a murine mouse model.•Minimally invasive longitudinal monitoring of "active" and "in remission" ulcerative colitis.•Our endoscopic based imaging modality can be used to validate the induction of ulcerative colitis and the potential treatment response for pre-clinical trials.
Collapse
Affiliation(s)
- Elizabeth A. Bullard
- Department of Biomedical Engineering, University of Arkansas, Fayetteville, AR, United States
| | - Ariel I. Mundo
- Department of Biomedical Engineering, University of Arkansas, Fayetteville, AR, United States
| | - Shelby N. Bess
- Department of Biomedical Engineering, University of Arkansas, Fayetteville, AR, United States
| | - Kathryn Miller Priest
- Department of Biomedical Engineering, University of Arkansas, Fayetteville, AR, United States
| | - Timothy J. Muldoon
- Department of Biomedical Engineering, University of Arkansas, Fayetteville, AR, United States
| |
Collapse
|
6
|
Orlova A, Pavlova K, Kurnikov A, Maslennikova A, Myagcheva M, Zakharov E, Skamnitskiy D, Perekatova V, Khilov A, Kovalchuk A, Moiseev A, Turchin I, Razansky D, Subochev P. Noninvasive optoacoustic microangiography reveals dose and size dependency of radiation-induced deep tumor vasculature remodeling. Neoplasia 2022; 26:100778. [PMID: 35220045 PMCID: PMC8889238 DOI: 10.1016/j.neo.2022.100778] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2021] [Revised: 02/04/2022] [Accepted: 02/11/2022] [Indexed: 01/07/2023]
Abstract
Tumor microvascular responses may provide a sensitive readout indicative of radiation therapy efficacy, its time course and dose dependencies. However, direct high-resolution observation and longitudinal monitoring of large-scale microvascular remodeling in deep tissues remained challenging with the conventional microscopy approaches. We report on a non-invasive longitudinal study of morphological and functional neovascular responses by means of scanning optoacoustic (ОА) microangiography. In vivo imaging of CT26 tumor response to a single irradiation at varying dose (6, 12, and 18 Gy) has been performed over ten days following treatment. Tumor oxygenation levels were further estimated using diffuse optical spectroscopy (DOS) with a contact fiber probe. OA revealed the formation of extended vascular structures on the whole tumor scale during its proliferation, whereas only short fragmented vascular regions were identified following irradiation. On the first day post treatment, a decrease in the density of small (capillary-sized) and medium-sized vessels was revealed, accompanied by an increase in their fragmentation. Larger vessels exhibited an increase in their density accompanied by a decline in the number of vascular segments. Short-lasting response has been observed after 6 and 12 Gy irradiations, whereas 18 Gy treatment resulted in prolonged responses, up to the tenth day after irradiation. DOS measurements further revealed a delayed increase of tumor oxygenation levels for 18 Gy irradiations, commencing on the sixth day post treatment. The ameliorated oxygenation is attributed to diminished oxygen consumption by inhibited tumor cells but not to the elevation of oxygen supply. This work is the first to demonstrate the differential (size-dependent) nature of vascular responses to radiation treatments at varying doses in vivo. The OA approach thus facilitates the study of radiation-induced vascular changes in an unperturbed in vivo environment while enabling deep tissue high-resolution observations at the whole tumor scale.
Collapse
|
7
|
Diffuse Optical Spectroscopy Monitoring of Experimental Tumor Oxygenation after Red and Blue Light Photodynamic Therapy. PHOTONICS 2021. [DOI: 10.3390/photonics9010019] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Photodynamic therapy (PDT) is an effective technique for cancer treatment based on photoactivation of photosensitizer accumulated in pathological tissues resulting in singlet oxygen production. Employment of red (660 nm) or blue (405 nm) light differing in typical penetration depth within the tissue for PDT performance provides wide opportunities for improving PDT protocols. Oxygenation dynamics in the treated area can be monitored using diffuse optical spectroscopy (DOS) which allows evaluating tumor response to treatment. In this study, we report on monitoring oxygenation dynamics in experimental tumors after PDT treatment with chlorin-based photosensitizers using red or blue light. The untreated and red light PDT groups demonstrate a gradual decrease in tumor oxygen saturation during the 7-day observation period, however, the reason is different: in the untreated group, the effect is explained by the excessive tumor growth, while in the PDT group, the effect is caused by the blood flow arrest preventing delivery of oxygenated blood to the tumor. The blue light PDT procedure, on the contrary, demonstrates the preservation of the blood oxygen saturation in the tumor during the entire observation period due to superficial action of the blue-light PDT and weaker tumor growth inhibition. Irradiation-only regimes show a primarily insignificant decrease in tumor oxygen saturation owing to partial inhibition of tumor growth. The DOS observations are interpreted based on histology analysis.
Collapse
|
8
|
Proposal for a Skin Layer-Wise Decomposition Model of Spatially-Resolved Diffuse Reflectance Spectra Based on Maximum Depth Photon Distributions: A Numerical Study. PHOTONICS 2021. [DOI: 10.3390/photonics8100444] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
In the context of cutaneous carcinoma diagnosis based on in vivo optical biopsy, Diffuse Reflectance (DR) spectra, acquired using a Spatially Resolved (SR) sensor configuration, can be analyzed to distinguish healthy from pathological tissues. The present contribution aims at studying the depth distribution of SR-DR-detected photons in skin from the perspective of analyzing how these photons contribute to acquired spectra carrying local physiological and morphological information. Simulations based on modified Cuda Monte Carlo Modeling of Light transport were performed on a five-layer human skin optical model with epidermal thickness, phototype and dermal blood content as variable parameters using (i) wavelength-resolved scattering and absorption properties and (ii) the geometrical configuration of a multi-optical fiber probe implemented on an SR-DR spectroscopic device currently used in clinics. Through histograms of the maximum probed depth and their exploitation, we provide numerical evidence linking the characteristic penetration depth of the detected photons to their wavelengths and four source–sensor distances, which made it possible to propose a decomposition of the DR signals related to skin layer contributions.
Collapse
|
9
|
Sun T, Zhu C. Empirical method for rapid quantification of intrinsic fluorescence signals of key metabolic probes from optical spectra measured on tissue-mimicking turbid medium. JOURNAL OF BIOMEDICAL OPTICS 2021; 26:JBO-210046R. [PMID: 33893727 PMCID: PMC8062794 DOI: 10.1117/1.jbo.26.4.045001] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/10/2021] [Accepted: 04/07/2021] [Indexed: 05/27/2023]
Abstract
SIGNIFICANCE Optical fluorescence spectroscopy technique has been explored extensively to quantify both glucose uptake and mitochondrial metabolism with proper fluorescent probes in small tumor models in vivo. However, it remains a great challenge to rapidly quantify the intrinsic metabolic fluorophores from the optically measured fluorescence spectra that contain significant distortions due to tissue absorption and scattering. AIM To enable rapid spectral data processing and quantify the in vivo metabolic parameters in real-time, we present an empirical ratio-metric method for rapid fluorescence spectra attenuation correction with high accuracy. APPROACH A first-order approximation of intrinsic fluorescence spectra can be obtained by dividing the fluorescence spectra by diffuse reflectance spectra with some variable powers. We further developed this approximation for rapid extraction of intrinsic key metabolic probes (2-NBDG for glucose uptake and TMRE for mitochondrial function) by dividing the distorted fluorescence spectra by diffuse reflectance intensities recorded at excitation and emission peak with a pair of system-dependent powers. Tissue-mimicking phantom studies were conducted to evaluate the method. RESULTS The tissue-mimicking phantom studies demonstrated that our empirical method could quantify the key intrinsic metabolic probes in near real-time with an average percent error of ∼5 % . CONCLUSIONS An empirical method was demonstrated for rapid quantification of key metabolic probes from fluorescence spectra measured on a tissue-mimicking turbid medium. The proposed method will potentially facilitate real-time monitoring of key metabolic parameters of tumor models in vivo using optical spectroscopy, which will significantly advance translational cancer research.
Collapse
Affiliation(s)
- Tengfei Sun
- University of Kentucky, Department of Biomedical Engineering, Lexington, Kentucky, United States
| | - Caigang Zhu
- University of Kentucky, Department of Biomedical Engineering, Lexington, Kentucky, United States
| |
Collapse
|
10
|
Kirillin M, Kurakina D, Khilov A, Orlova A, Shakhova M, Orlinskaya N, Sergeeva E. Red and blue light in antitumor photodynamic therapy with chlorin-based photosensitizers: a comparative animal study assisted by optical imaging modalities. BIOMEDICAL OPTICS EXPRESS 2021; 12:872-892. [PMID: 33680547 PMCID: PMC7901330 DOI: 10.1364/boe.411518] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/01/2020] [Revised: 12/08/2020] [Accepted: 12/14/2020] [Indexed: 05/10/2023]
Abstract
The goal of this study is a comparative analysis of the efficiency of the PDT protocols for CT26 tumor model treatment in Balb/c mice employing red and blue light with both topical and intravenous administration of chlorin-based photosensitizers (PSs). The considered protocols include the doses of 250 J/cm2 delivered at 660 nm, 200 J/cm2 delivered at 405 nm, and 250 J/cm2 delivered at both wavelengths with equal energy density contribution. Dual-wavelength fluorescence imaging was employed to estimate both photobleaching efficiency, typical photobleaching rates and the procedure impact depth, while optical coherence tomography with angiography modality (OCT-A) was employed to monitor the tumor vasculature response for up to 7 days after the procedure with subsequent histology inspection. Red light or dual-wavelength PDT regimes with intravenous PS injection were demonstrated to provide the most pronounced tumor response among all the considered cases. On the contrary, blue light regimes were demonstrated to be most efficient among topical application and irradiation only regimes. Tumor size dynamics for different groups is in good agreement with the tumor response predictions based on OCT-A taken in 24h after exposure and the results of histology analysis performed in 7 days after the exposure.
Collapse
Affiliation(s)
- Mikhail Kirillin
- Institute of Applied Physics RAS, 46 Ulyanov St., Nizhny Novgorod, 603950, Russia
| | - Daria Kurakina
- Institute of Applied Physics RAS, 46 Ulyanov St., Nizhny Novgorod, 603950, Russia
| | - Aleksandr Khilov
- Institute of Applied Physics RAS, 46 Ulyanov St., Nizhny Novgorod, 603950, Russia
| | - Anna Orlova
- Institute of Applied Physics RAS, 46 Ulyanov St., Nizhny Novgorod, 603950, Russia
| | - Maria Shakhova
- Institute of Applied Physics RAS, 46 Ulyanov St., Nizhny Novgorod, 603950, Russia
- Privolzhsky Research Medical University, 10/1 Minin and Pozharsky Sq., Nizhny Novgorod, 603950, Russia
| | - Natalia Orlinskaya
- Institute of Applied Physics RAS, 46 Ulyanov St., Nizhny Novgorod, 603950, Russia
- Privolzhsky Research Medical University, 10/1 Minin and Pozharsky Sq., Nizhny Novgorod, 603950, Russia
| | - Ekaterina Sergeeva
- Institute of Applied Physics RAS, 46 Ulyanov St., Nizhny Novgorod, 603950, Russia
| |
Collapse
|
11
|
Carrico E, Sun T, Zhu C. Numerical investigation of depth-sensitive diffuse reflectance and fluorescence measurements on murine subcutaneous tissue with growing solid tumors. BIOMEDICAL OPTICS EXPRESS 2020; 11:6311-6323. [PMID: 33282492 PMCID: PMC7687953 DOI: 10.1364/boe.405321] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/13/2020] [Revised: 09/24/2020] [Accepted: 10/05/2020] [Indexed: 05/08/2023]
Abstract
In most biomedical optical spectroscopy platforms, a fiber-probe consisting of single or multiple illumination and collection fibers was commonly used for the delivery of illuminating light and the collection of emitted light. Typically, the signals from all collection fibers were combined and then sampled to characterize tissue samples. Such simple averaged optical measurements may induce significant errors for in vivo tumor characterization, especially in longitudinal studies where the tumor size and location vary with tumor stages. In this study, we utilized the Monte Carlo technique to optimize the fiber-probe geometries of a spectroscopy platform to enable tumor-sensitive diffuse reflectance and fluorescence measurements on murine subcutaneous tissues with growing solid tumors that have different sizes and depths. Our data showed that depth-sensitive techniques offer improved sensitivity in tumor detection compared to the simple averaged approach in both reflectance and fluorescence measurements. Through the numerical studies, we optimized the source-detector distances, fiber diameters, and numerical apertures for sensitive measurement of small solid tumors with varying size and depth buried in murine subcutaneous tissues. Our study will advance the design of a fiber-probe in an optical spectroscopy system that can be used for longitudinal tumor metabolism and vasculature monitoring.
Collapse
Affiliation(s)
- Evan Carrico
- Department of Electrical Engineering, University of Kentucky, Lexington, KY 40506, USA
| | - Tengfei Sun
- Department of Biomedical Engineering, University of Kentucky, Lexington, KY 40506, USA
| | - Caigang Zhu
- Department of Biomedical Engineering, University of Kentucky, Lexington, KY 40506, USA
| |
Collapse
|
12
|
Mundo AI, Greening GJ, Fahr MJ, Hale LN, Bullard EA, Rajaram N, Muldoon TJ. Diffuse reflectance spectroscopy to monitor murine colorectal tumor progression and therapeutic response. JOURNAL OF BIOMEDICAL OPTICS 2020; 25:1-16. [PMID: 32141266 PMCID: PMC7058691 DOI: 10.1117/1.jbo.25.3.035002] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/10/2020] [Accepted: 02/17/2020] [Indexed: 05/08/2023]
Abstract
SIGNIFICANCE Many studies in colorectal cancer (CRC) use murine ectopic tumor models to determine response to treatment. However, these models do not replicate the tumor microenvironment of CRC. Physiological information of treatment response derived via diffuse reflectance spectroscopy (DRS) from murine primary CRC tumors provide a better understanding for the development of new drugs and dosing strategies in CRC. AIM Tumor response to chemotherapy in a primary CRC model was quantified via DRS to extract total hemoglobin content (tHb), oxygen saturation (StO2), oxyhemoglobin, and deoxyhemoglobin in tissue. APPROACH A multimodal DRS and imaging probe (0.78 mm outside diameter) was designed and validated to acquire diffuse spectra longitudinally-via endoscopic guidance-in developing colon tumors under 5-fluoruracil (5-FU) maximum-tolerated (MTD) and metronomic regimens. A filtering algorithm was developed to compensate for positional uncertainty in DRS measurements Results: A maximum increase in StO2 was observed in both MTD and metronomic chemotherapy-treated murine primary CRC tumors at week 4 of neoadjuvant chemotherapy, with 21 ± 6 % and 17 ± 6 % fold changes, respectively. No significant changes were observed in tHb. CONCLUSION Our study demonstrates the feasibility of DRS to quantify response to treatment in primary CRC models.
Collapse
Affiliation(s)
- Ariel I. Mundo
- University of Arkansas, Department of Biomedical Engineering, Fayetteville, Arkansas, United States
| | - Gage. J. Greening
- University of Arkansas, Department of Biomedical Engineering, Fayetteville, Arkansas, United States
| | - Michael J. Fahr
- University of Arkansas, Department of Computer Science, Fayetteville, Arkansas, United States
| | - Lawrence N. Hale
- University of Arkansas, Department of Chemistry and Biochemistry, Fayetteville, Arkansas, United States
| | - Elizabeth A. Bullard
- University of Arkansas, Department of Biomedical Engineering, Fayetteville, Arkansas, United States
| | - Narasimhan Rajaram
- University of Arkansas, Department of Biomedical Engineering, Fayetteville, Arkansas, United States
| | - Timothy J. Muldoon
- University of Arkansas, Department of Biomedical Engineering, Fayetteville, Arkansas, United States
- Address all correspondence to Timothy J. Muldoon, E-mail:
| |
Collapse
|
13
|
Greening G, Bess S, Muldoon T. Immunohistochemistry Staining for Tumor-associated Macrophage Polarization in Murine Subcutaneous Colon Tumor Allografts. Bio Protoc 2018. [DOI: 10.21769/bioprotoc.3106] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022] Open
|