1
|
Picazo-Bueno JÁ, Ketelhut S, Schnekenburger J, Micó V, Kemper B. Off-axis digital lensless holographic microscopy based on spatially multiplexed interferometry. JOURNAL OF BIOMEDICAL OPTICS 2024; 29:S22715. [PMID: 39161785 PMCID: PMC11331263 DOI: 10.1117/1.jbo.29.s2.s22715] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/29/2024] [Revised: 06/23/2024] [Accepted: 07/17/2024] [Indexed: 08/21/2024]
Abstract
Significance Digital holographic microscopy (DHM) is a label-free microscopy technique that provides time-resolved quantitative phase imaging (QPI) by measuring the optical path delay of light induced by transparent biological samples. DHM has been utilized for various biomedical applications, such as cancer research and sperm cell assessment, as well as for in vitro drug or toxicity testing. Its lensless version, digital lensless holographic microscopy (DLHM), is an emerging technology that offers size-reduced, lightweight, and cost-effective imaging systems. These features make DLHM applicable, for example, in limited resource laboratories, remote areas, and point-of-care applications. Aim In addition to the abovementioned advantages, in-line arrangements for DLHM also include the limitation of the twin-image presence, which can restrict accurate QPI. We therefore propose a compact lensless common-path interferometric off-axis approach that is capable of quantitative imaging of fast-moving biological specimens, such as living cells in flow. Approach We suggest lensless spatially multiplexed interferometric microscopy (LESSMIM) as a lens-free variant of the previously reported spatially multiplexed interferometric microscopy (SMIM) concept. LESSMIM comprises a common-path interferometric architecture that is based on a single diffraction grating to achieve digital off-axis holography. From a series of single-shot off-axis holograms, twin-image free and time-resolved QPI is achieved by commonly used methods for Fourier filtering-based reconstruction, aberration compensation, and numerical propagation. Results Initially, the LESSMIM concept is experimentally demonstrated by results from a resolution test chart and investigations on temporal stability. Then, the accuracy of QPI and capabilities for imaging of living adherent cell cultures is characterized. Finally, utilizing a microfluidic channel, the cytometry of suspended cells in flow is evaluated. Conclusions LESSMIM overcomes several limitations of in-line DLHM and provides fast time-resolved QPI in a compact optical arrangement. In summary, LESSMIM represents a promising technique with potential biomedical applications for fast imaging such as in imaging flow cytometry or sperm cell analysis.
Collapse
Affiliation(s)
- José Ángel Picazo-Bueno
- University of Muenster, Biomedical Technology Center, Muenster, Germany
- University of Valencia, Department of Optics, Optometry and Vision Science, Burjassot, Spain
| | - Steffi Ketelhut
- University of Muenster, Biomedical Technology Center, Muenster, Germany
| | | | - Vicente Micó
- University of Valencia, Department of Optics, Optometry and Vision Science, Burjassot, Spain
| | - Björn Kemper
- University of Muenster, Biomedical Technology Center, Muenster, Germany
| |
Collapse
|
2
|
Micó V, Rogalski M, Picazo-Bueno JÁ, Trusiak M. Single-shot wavelength-multiplexed phase microscopy under Gabor regime in a regular microscope embodiment. Sci Rep 2023; 13:4257. [PMID: 36918618 PMCID: PMC10015059 DOI: 10.1038/s41598-023-31300-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2022] [Accepted: 03/09/2023] [Indexed: 03/16/2023] Open
Abstract
Phase imaging microscopy under Gabor regime has been recently reported as an extremely simple, low cost and compact way to update a standard bright-field microscope with coherent sensing capabilities. By inserting coherent illumination in the microscope embodiment and producing a small defocus distance of the sample at the input plane, the digital sensor records an in-line Gabor hologram of the target sample, which is then numerically post-processed to finally achieve the sample's quantitative phase information. However, the retrieved phase distribution is affected by the two well-known drawbacks when dealing with Gabor's regime, that is, coherent noise and twin image disturbances. Here, we present a single-shot technique based on wavelength multiplexing for mitigating these two effects. A multi-illumination laser source (including 3 diode lasers) illuminates the sample and a color digital sensor (conventional RGB color camera) is used to record the wavelength-multiplexed Gabor hologram in a single exposure. The technique is completed by presenting a novel algorithm based on a modified Gerchberg-Saxton kernel to finally retrieve an enhanced quantitative phase image of the sample, enhanced in terms of coherent noise removal and twin image minimization. Experimental validations are performed in a regular Olympus BX-60 upright microscope using a 20X 0.46NA objective lens and considering static (resolution test targets) and dynamic (living spermatozoa) phase samples.
Collapse
Affiliation(s)
- Vicente Micó
- Departamento de Óptica y Optometría y Ciencias de la Visión, Universidad de Valencia, C/Doctor Moliner 50, 46100, Burjassot, Spain.
| | - Mikołaj Rogalski
- Institute of Micromechanics and Photonics, Warsaw University of Technology, 8 Sw. A. Boboli St., 02‑525, Warsaw, Poland
| | - José Ángel Picazo-Bueno
- Departamento de Óptica y Optometría y Ciencias de la Visión, Universidad de Valencia, C/Doctor Moliner 50, 46100, Burjassot, Spain
| | - Maciej Trusiak
- Institute of Micromechanics and Photonics, Warsaw University of Technology, 8 Sw. A. Boboli St., 02‑525, Warsaw, Poland
| |
Collapse
|
3
|
Picazo-Bueno JÁ, Barroso Á, Ketelhut S, Schnekenburger J, Micó V, Kemper B. Single capture bright field and off-axis digital holographic microscopy. OPTICS LETTERS 2023; 48:876-879. [PMID: 36790964 DOI: 10.1364/ol.478674] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/18/2022] [Accepted: 12/19/2022] [Indexed: 06/18/2023]
Abstract
We report on a single capture approach for simultaneous incoherent bright field (BF) and laser-based quantitative phase imaging (QPI). Common-path digital holographic microscopy (DHM) is implemented in parallel with BF imaging within the optical path of a commercial optical microscope to achieve spatially multiplexed recording of white light images and digital off-axis holograms, which are subsequently numerically demultiplexed. The performance of the proposed multimodal concept is firstly determined by investigations on microspheres. Then, the application for label-free dual-mode QPI and BF imaging of living pancreatic tumor cells is demonstrated.
Collapse
|
4
|
Li Y, Liu L, Liu Y, Wang M, Zhong Z, Shan M. Off-axis common-path digital holography using a cube beam splitter. APPLIED OPTICS 2022; 61:5062-5066. [PMID: 36256184 DOI: 10.1364/ao.458168] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/10/2022] [Accepted: 05/16/2022] [Indexed: 06/16/2023]
Abstract
An off-axis common-path digital holography is built up by inserting a 45° tilted cube beam splitter (CBS) into a 4f system that is described in this paper. Two apertures are set as the input of the 4f system, where one supports the object, and the other is vacant. The CBS divides the incoming beam into two copies, which are symmetrical with each other along the semi-reflecting layer. Due to the separation of two beams in a Fourier plane and the flipping of the field of view induced by the CBS, an off-axis hologram can be captured. Moreover, the carrier frequency can be easily modulated by translating the CBS perpendicular to the optical axis. The new proposed scheme has high light utilization, a compact setup, and high temporal stability. The experiments are carried out to demonstrate the validity and stability of the proposed method.
Collapse
|
5
|
Picazo-Bueno JA, Micó V. Optical module for single-shot quantitative phase imaging based on the transport of intensity equation with field of view multiplexing. OPTICS EXPRESS 2021; 29:39904-39919. [PMID: 34809345 DOI: 10.1364/oe.439047] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/01/2021] [Accepted: 10/18/2021] [Indexed: 06/13/2023]
Abstract
We present a cost-effective, simple, and robust method that enables single-shot quantitative phase imaging (QPI) based on the transport of intensity equation (TIE) using an add-on optical module that can be assembled into the exit port of any regular microscope. The module integrates a beamsplitter (BS) cube (placed in a non-conventional way) for duplicating the output image onto the digital sensor (field of view - FOV - multiplexing), a Stokes lens (SL) for astigmatism compensation (introduced by the BS cube), and an optical quality glass plate over one of the FOV halves for defocusing generation (needed for single-shot TIE algorithm). Altogether, the system provides two laterally separated intensity images that are simultaneously recorded and slightly defocused one to each other, thus enabling accurate QPI by conventional TIE-based algorithms in a single snapshot. The proposed optical module is first calibrated for defining the configuration providing best QPI performance and, second, experimentally validated by using different phase samples (static and dynamic ones). The proposed configuration might be integrated in a compact three-dimensional (3D) printed module and coupled to any conventional microscope for QPI of dynamic transparent samples.
Collapse
|
6
|
Zdańkowski P, Winnik J, Patorski K, Gocłowski P, Ziemczonok M, Józwik M, Kujawińska M, Trusiak M. Common-path intrinsically achromatic optical diffraction tomography. BIOMEDICAL OPTICS EXPRESS 2021; 12:4219-4234. [PMID: 34457410 PMCID: PMC8367224 DOI: 10.1364/boe.428828] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/26/2021] [Revised: 06/05/2021] [Accepted: 06/07/2021] [Indexed: 06/13/2023]
Abstract
In this work we propose an open-top like common-path intrinsically achromatic optical diffraction tomography system. It operates as a total-shear interferometer and employs Ronchi-type amplitude diffraction grating, positioned in between the camera and the tube lens without an additional 4f system, generating three-beam interferograms with achromatic second harmonic. Such configuration makes the proposed system low cost, compact and immune to vibrations. We present the results of the measurements of 3D-printed cell phantom using laser diode (coherent) and superluminescent diode (partially coherent) light sources. Broadband light sources can be naturally employed without the need for any cumbersome compensation because of the intrinsic achromaticity of the interferometric recording (holograms generated by -1st and +1st conjugated diffraction orders are not affected by the illumination wavelength). The results show that the decreased coherence offers much reduced coherent noise and higher fidelity tomographic reconstruction especially when applied nonnegativity constraint regularization procedure.
Collapse
Affiliation(s)
- Piotr Zdańkowski
- Warsaw University of Technology, Institute of Micromechanics and Photonics, 8 Św. A. Boboli st., 02-525 Warsaw, Poland
- These authors contributed equally to this work
| | - Julianna Winnik
- Warsaw University of Technology, Institute of Micromechanics and Photonics, 8 Św. A. Boboli st., 02-525 Warsaw, Poland
- These authors contributed equally to this work
| | - Krzysztof Patorski
- Warsaw University of Technology, Institute of Micromechanics and Photonics, 8 Św. A. Boboli st., 02-525 Warsaw, Poland
| | - Paweł Gocłowski
- Warsaw University of Technology, Institute of Micromechanics and Photonics, 8 Św. A. Boboli st., 02-525 Warsaw, Poland
| | - Michał Ziemczonok
- Warsaw University of Technology, Institute of Micromechanics and Photonics, 8 Św. A. Boboli st., 02-525 Warsaw, Poland
| | - Michał Józwik
- Warsaw University of Technology, Institute of Micromechanics and Photonics, 8 Św. A. Boboli st., 02-525 Warsaw, Poland
| | - Małgorzata Kujawińska
- Warsaw University of Technology, Institute of Micromechanics and Photonics, 8 Św. A. Boboli st., 02-525 Warsaw, Poland
| | - Maciej Trusiak
- Warsaw University of Technology, Institute of Micromechanics and Photonics, 8 Św. A. Boboli st., 02-525 Warsaw, Poland
| |
Collapse
|
7
|
Trusiak M. Fringe analysis: single-shot or two-frames? Quantitative phase imaging answers. OPTICS EXPRESS 2021; 29:18192-18211. [PMID: 34154081 DOI: 10.1364/oe.423336] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/26/2021] [Accepted: 04/28/2021] [Indexed: 06/13/2023]
Abstract
Conditions of the digital recording of the fringe pattern determine the phase reconstruction procedure, which in turn directly shapes the final accuracy and throughput of the full-field (non-scanning) optical measurement technique and defines the system capabilities. In this way, the fringe pattern analysis plays a crucial role in the ubiquitous optical measurements and thus is under constant development focused on high temporal/spatial resolution. It is especially valuable in the quantitative phase imaging technology, which emerged in the high-contrast label-free biomedical microscopy. In this paper, I apply recently blossomed two-frame phase-shifting techniques to the QPI and merge them with advanced adaptive interferogram pre-filtering algorithms. Next, I comprehensively test such frameworks against classical and adaptive single-shot methods applied for phase reconstruction in dynamic QPI enabling highest phase time-space-bandwidth product. The presented study systematically tackles important question: what is the gain, if any, in QPI realized by recording two phase-shifted interferograms? Counterintuitively, the results show that single-shot demodulation exhibited higher phase reconstruction accuracy than two-frame phase-shifting methods in low and medium interferogram signal-to-noise ratio regimes. Thus, the single-shot approach is promoted due to not only high temporal resolution but also larger phase-information throughput. Additionally, in the majority of scenarios, the best option is to shift the paradigm and employ two-frame pre-filtering rather than two-frame phase retrieval. Experimental fringe analysis in QPI of LSEC/RWPE cell lines successfully corroborated all novel numerical findings. Hence, the presented numerical-experimental research advances the important field of fringe analysis solutions for optical full-field measurement methods with widespread bio-engineering applications.
Collapse
|
8
|
Castañeda R, Buitrago-Duque C, Garcia-Sucerquia J, Doblas A. Fast-iterative blind phase-shifting digital holographic microscopy using two images. APPLIED OPTICS 2020; 59:7469-7476. [PMID: 32902516 DOI: 10.1364/ao.398352] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/22/2020] [Accepted: 07/20/2020] [Indexed: 06/11/2023]
Abstract
Digital holographic microscopy (DHM) has consolidated as a tool for diagnosis and measuring in life sciences, thanks to its capability to perform quantitative phase imaging. The reduction of the acquisition and computation time has driven the development of diverse reconstruction methodologies using a single-shot and two-frame approach. Methods based on the Fourier transform, the Hilbert transform, and the phase derivative are counted among the most utilized. The sensitivity of those methods is highly dependent on the compensation of the phase step, which requires the accurate knowledge of the phase shift between the two recorded holograms. Here, an alternative fast-iterative method based on the demodulation of the different components of the recorded interferograms is presented. The novelties of the proposed two-frame approach are: minimum number of images, since it requires 2 recorded holograms; a minimum phase error of the order of 0.005% independently of the phase step ranging from 0 to 180 deg.; a maximum correlation coefficient equal to 1 between the phase and the retrieved phase image; and, finally, a reduced processing time compared with the previous three-frame approach. Experimental results demonstrate the goodness and feasibility of the proposed technique.
Collapse
|
9
|
Trusiak M, Cywińska M, Micó V, Picazo-Bueno JÁ, Zuo C, Zdańkowski P, Patorski K. Variational Hilbert Quantitative Phase Imaging. Sci Rep 2020; 10:13955. [PMID: 32811839 PMCID: PMC7435195 DOI: 10.1038/s41598-020-69717-1] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2019] [Accepted: 07/15/2020] [Indexed: 11/09/2022] Open
Abstract
Utilizing the refractive index as the endogenous contrast agent to noninvasively study transparent cells is a working principle of emerging quantitative phase imaging (QPI). In this contribution, we propose the Variational Hilbert Quantitative Phase Imaging (VHQPI)-end-to-end purely computational add-on module able to improve performance of a QPI-unit without hardware modifications. The VHQPI, deploying unique merger of tailored variational image decomposition and enhanced Hilbert spiral transform, adaptively provides high quality map of sample-induced phase delay, accepting particularly wide range of input single-shot interferograms (from off-axis to quasi on-axis configurations). It especially promotes high space-bandwidth-product QPI configurations alleviating the spectral overlapping problem. The VHQPI is tailored to deal with cumbersome interference patterns related to detailed locally varying biological objects with possibly high dynamic range of phase and relatively low carrier. In post-processing, the slowly varying phase-term associated with the instrumental optical aberrations is eliminated upon variational analysis to further boost the phase-imaging capabilities. The VHQPI is thoroughly studied employing numerical simulations and successfully validated using static and dynamic cells phase-analysis. It compares favorably with other single-shot phase reconstruction techniques based on the Fourier and Hilbert-Huang transforms, both in terms of visual inspection and quantitative evaluation, potentially opening up new possibilities in QPI.
Collapse
Affiliation(s)
- Maciej Trusiak
- Institute of Micromechanics and Photonics, Warsaw University of Technology, 8 Sw. A. Boboli St., 02-525, Warsaw, Poland.
| | - Maria Cywińska
- Institute of Micromechanics and Photonics, Warsaw University of Technology, 8 Sw. A. Boboli St., 02-525, Warsaw, Poland.
| | - Vicente Micó
- Departamento de Óptica y de Optometría y Ciencias de la Visión, Facultad de Física, Universitat de Valencia, C/Doctor Moliner 50, 46100, Burjassot, Spain
| | - José Ángel Picazo-Bueno
- Departamento de Óptica y de Optometría y Ciencias de la Visión, Facultad de Física, Universitat de Valencia, C/Doctor Moliner 50, 46100, Burjassot, Spain
| | - Chao Zuo
- Jiangsu Key Laboratory of Spectral Imaging and Intelligence Sense, Nanjing University of Science and Technology, Nanjing, 210094, Jiangsu, China
| | - Piotr Zdańkowski
- Institute of Micromechanics and Photonics, Warsaw University of Technology, 8 Sw. A. Boboli St., 02-525, Warsaw, Poland
| | - Krzysztof Patorski
- Institute of Micromechanics and Photonics, Warsaw University of Technology, 8 Sw. A. Boboli St., 02-525, Warsaw, Poland
| |
Collapse
|
10
|
Hai N, Rosen J. Doubling the acquisition rate by spatial multiplexing of holograms in coherent sparse coded aperture correlation holography. OPTICS LETTERS 2020; 45:3439-3442. [PMID: 32630866 DOI: 10.1364/ol.394475] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/06/2020] [Accepted: 05/17/2020] [Indexed: 06/11/2023]
Abstract
Optical, spatial, or temporal multiplexing is a well-known approach to optimize the performance of imaging systems. Following the recent discovery about the capability to record a coherent hologram in an interferenceless working mode, we propose a motionless method to spatially multiplex more than one hologram in a single camera exposure. Using the rather simple multiplexing framework based on coded aperture correlation holography, we effectively increase the acquisition rate of dynamic scenes and the holographic data compression by two-fold. Quantitative or qualitative phase microscopy and acquisition of a bipolar hologram from a single camera shot, experimentally confirm the applicability of the suggested technique.
Collapse
|
11
|
Guo R, Mirsky SK, Barnea I, Dudaie M, Shaked NT. Quantitative phase imaging by wide-field interferometry with variable shearing distance uncoupled from the off-axis angle. OPTICS EXPRESS 2020; 28:5617-5628. [PMID: 32121778 DOI: 10.1364/oe.385437] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/10/2019] [Accepted: 01/12/2020] [Indexed: 05/20/2023]
Abstract
We introduce a new shearing interferometry module for digital holographic microscopy, in which the off-axis angle, which defines the interference fringe frequency, is not coupled to the shearing distance, as is the case in most shearing interferometers. Thus, it enables the selection of shearing distance based on the spatial density of the sample, without losing spatial frequency content due to overlapping of the complex wave fronts in the spatial frequency domain. Our module is based on a 4f imaging unit and a diffraction grating, in which the hologram is generated from two mutually coherent, partially overlapping sample beams, with adjustable shearing distance, as defined by the position of the grating, but with a constant off-axis angle, as defined by the grating period. The module is simple, easy to align, and presents a nearly common-path geometry. By placing this module as an add-on unit at the exit port of an inverted microscope, quantitative phase imaging can easily be performed. The system is characterized by a 2.5 nm temporal stability and a 3.4 nm spatial stability, without using anti-vibration techniques. We provide quantitative phase imaging experiments of silica beads with different shearing distances, red blood cell fluctuations, and cancer cells flowing in a micro-channel, which demonstrate the capability and versatility of our approach in different imaging scenarios.
Collapse
|