1
|
Tanskanen A, Malone J, MacAulay C, Lane P. Multipath artifacts enable angular contrast in multimodal endoscopic optical coherence tomography. OPTICS EXPRESS 2023; 31:44224-44245. [PMID: 38178499 DOI: 10.1364/oe.504854] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/01/2023] [Accepted: 11/29/2023] [Indexed: 01/06/2024]
Abstract
Multipath artifacts are inherent to double-clad fiber based optical coherence tomography (OCT), appearing as ghost images blurred in the A-line direction. They result from the excitation of higher-order inner-cladding modes in the OCT sample arm which cross-couple into the fundamental mode at discontinuities and thus are detected in single-mode fiber-based interferometers. Historically, multipath artifacts have been regarded as a drawback in single fiber endoscopic multimodal OCT systems as they degrade OCT quality. In this work, we reveal that multipath artifacts can be projected into high-quality two-dimensional en face images which encode high angle backscattering features. Using a combination of experiment and simulation, we characterize the coupling of Mie-range scatterers into the fundamental image (LP01 mode) and higher-order image (multipath artifact). This is validated experimentally through imaging of microspheres with an endoscopic multimodal OCT system. The angular dependence of the fundamental image and higher order image generated by the multipath artifact lays the basis for multipath contrast, a ratiometric measurement of differential coupling which provides information regarding the angular diversity of a sample. Multipath contrast images can be generated from OCT data where multipath artifacts are present, meaning that a wealth of clinical data can be retrospectively examined.
Collapse
|
2
|
Kubo T. Optical Coherence Tomography in Vulnerable Plaque and Acute Coronary Syndrome. Interv Cardiol Clin 2023; 12:203-214. [PMID: 36922061 DOI: 10.1016/j.iccl.2022.10.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Optical coherence tomography (OCT) is an intravascular imaging technique that uses near-infrared light. OCT provides high-resolution cross-sectional images of coronary arteries and enables tissue characterization of atherosclerotic plaques. OCT can identify plaque rupture, plaque erosion, and calcified nodule in culprit lesions of acute coronary syndrome. OCT can also detect important morphologic features of vulnerable plaques such as thin fibrous caps, large lipid cores, macrophages accumulation, intraplaque microvasculature, cholesterol crystals, healed plaques, and intraplaque hemorrhage.
Collapse
Affiliation(s)
- Takashi Kubo
- Department of Cardiovascular Medicine, Naga Municipal Hospital, 1282 Uchita, Kinokawa, Wakayama 649-6414, Japan.
| |
Collapse
|
3
|
Otuya DO, Dechene NM, Poshtupaka D, Judson S, Carlson CJ, Zemlok SK, Sevieri E, Choy P, Shore RE, De León‐Peralta E, Cirio AA, Rihm TW, Krall AA, Gavgiotaki E, Dong J, Silva SL, Baillargeon A, Baldwin G, Gao AH, Jansa Z, Barrios A, Ryan E, Bhat NGM, Balmasheva I, Chung A, Grant CN, Bablouzian AL, Beatty M, Ahsen OO, Zheng H, Tearney GJ. Passively scanned, single-fiber optical coherence tomography probes for gastrointestinal devices. Lasers Surg Med 2022; 54:935-944. [PMID: 35708124 PMCID: PMC9541095 DOI: 10.1002/lsm.23576] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2022] [Revised: 05/31/2022] [Accepted: 06/03/2022] [Indexed: 10/25/2022]
Abstract
BACKGROUND/OBJECTIVES Optical coherence tomography (OCT) uses low coherence interferometry to obtain depth-resolved tissue reflectivity profiles (M-mode) and transverse beam scanning to create images of two-dimensional tissue morphology (B-mode). Endoscopic OCT imaging probes typically employ proximal or distal mechanical beam scanning mechanisms that increase cost, complexity, and size. Here, we demonstrate in the gastrointestinal (GI) tracts of unsedated human patients, that a passive, single-fiber probe can be used to guide device placement, conduct device-tissue physical contact sensing, and obtain two-dimensional OCT images via M-to-B-mode conversion. MATERIALS AND METHODS We designed and developed ultrasmall, manually scannable, side- and forward-viewing single fiber-optic probes that can capture M-mode OCT data. Side-viewing M-mode OCT probes were incorporated into brush biopsy devices designed to harvest the microbiome and forward-viewing M-mode OCT probes were integrated into devices that measure intestinal potential difference (IPD). The M-mode OCT probe-coupled devices were utilized in the GI tract in six unsedated patients in vivo. M-mode data were converted into B-mode images using an M-to-B-mode conversion algorithm. The effectiveness of physical contact sensing by the M-mode OCT probes was assessed by comparing the variances of the IPD values when the probe was in physical contact with the tissue versus when it was not. The capacity of forward- and side-viewing M-mode OCT probes to produce high-quality B-mode images was compared by computing the percentages of the M-to-B-mode images that showed close contact between the probe and the luminal surface. Passively scanned M-to-B-mode images were qualitatively compared to B-mode images obtained by mechanical scanning OCT tethered capsule endomicroscopy (TCE) imaging devices. RESULTS The incorporation of M-mode OCT probes in these nonendoscopic GI devices safely and effectively enabled M-mode OCT imaging, facilitating real-time device placement guidance and contact sensing in vivo. Results showed that M-mode OCT contact sensing improved the variance of IPD measurements threefold and side-viewing probes increased M-to-B-mode image visibility by 10%. Images of the esophagus, stomach, and duodenum generated by the passively scanned probes and M-to-B-mode conversion were qualitatively superior to B-mode images obtained by mechanically scanning OCT TCE devices. CONCLUSION These results show that passive, single optical fiber OCT probes can be effectively utilized for nonendoscopic device placement guidance, device contact sensing, and two-dimensional morphologic imaging in the human GI tract in vivo. Due to their small size, lower cost, and reduced complexity, these M-mode OCT probes may provide an easier avenue for the incorporation of OCT functionality into endoscopic/nonendoscopic devices.
Collapse
|
4
|
Li C, Bec J, Zhou X, Marcu L. Dual-modality fluorescence lifetime imaging-optical coherence tomography intravascular catheter system with freeform catheter optics. JOURNAL OF BIOMEDICAL OPTICS 2022; 27:076005. [PMID: 35864574 PMCID: PMC9300477 DOI: 10.1117/1.jbo.27.7.076005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/17/2022] [Accepted: 06/27/2022] [Indexed: 06/15/2023]
Abstract
SIGNIFICANCE Intravascular imaging is key to investigations into atherosclerotic plaque pathobiology and cardiovascular diagnostics overall. The development of multimodal imaging devices compatible with intracoronary applications has the potential to address limitations of currently available single-modality systems. AIM We designed and characterized a robust, high performance multimodal imaging system that combines optical coherence tomography (OCT) and multispectral fluorescence lifetime imaging (FLIm) for intraluminal simultaneous assessment of structural and biochemical properties of coronary arteries. APPROACH Several shortcomings of existing FLIm-OCT catheter systems are addressed by adopting key features, namely (1) a custom fiber optic rotary joint based on an air bearing, (2) a broadband catheter using a freeform reflective optics, and (3) integrated solid-state FLIm detectors. Improvements are quantified using a combination of experimental characterization and simulations. RESULTS Excellent UV and IR coupling efficiencies and stability (IR: 75.7 % ± 0.4 % , UV: 45.7 % ± 0.35 % ) are achieved; high FLIm optical performance is obtained (UV beam FWHM: 50 μm) contemporaneously with excellent OCT beam quality (IR beam FWHM: 17 μm). High-quality FLIm OCT image of a human coronary artery specimen was acquired. CONCLUSION The ability of this intravascular imaging system to provide comprehensive structural and biochemical properties will be valuable to further our understanding of plaque pathophysiology and improve cardiovascular diagnostics.
Collapse
Affiliation(s)
- Cai Li
- University of California, Department of Biomedical Engineering, Davis, California, United States
| | - Julien Bec
- University of California, Department of Biomedical Engineering, Davis, California, United States
| | - Xiangnan Zhou
- University of California, Department of Biomedical Engineering, Davis, California, United States
| | - Laura Marcu
- University of California, Department of Biomedical Engineering, Davis, California, United States
| |
Collapse
|
5
|
Chen H, Agrawal S, Osman M, Minotto J, Mirg S, Liu J, Dangi A, Tran Q, Jackson T, Kothapalli SR. A Transparent Ultrasound Array for Real-Time Optical, Ultrasound, and Photoacoustic Imaging. BME FRONTIERS 2022; 2022:9871098. [PMID: 37850172 PMCID: PMC10521654 DOI: 10.34133/2022/9871098] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2021] [Accepted: 04/28/2022] [Indexed: 10/19/2023] Open
Abstract
Objective and Impact Statement. Simultaneous imaging of ultrasound and optical contrasts can help map structural, functional, and molecular biomarkers inside living subjects with high spatial resolution. There is a need to develop a platform to facilitate this multimodal imaging capability to improve diagnostic sensitivity and specificity. Introduction. Currently, combining ultrasound, photoacoustic, and optical imaging modalities is challenging because conventional ultrasound transducer arrays are optically opaque. As a result, complex geometries are used to coalign both optical and ultrasound waves in the same field of view. Methods. One elegant solution is to make the ultrasound transducer transparent to light. Here, we demonstrate a novel transparent ultrasound transducer (TUT) linear array fabricated using a transparent lithium niobate piezoelectric material for real-time multimodal imaging. Results. The TUT-array consists of 64 elements and centered at ~6 MHz frequency. We demonstrate a quad-mode ultrasound, Doppler ultrasound, photoacoustic, and fluorescence imaging in real-time using the TUT-array directly coupled to the tissue mimicking phantoms. Conclusion. The TUT-array successfully showed a multimodal imaging capability and has potential applications in diagnosing cancer, neurological, and vascular diseases, including image-guided endoscopy and wearable imaging.
Collapse
Affiliation(s)
- Haoyang Chen
- Department of Biomedical Engineering, The Pennsylvania State University, University Park, PA 16802, USA
| | - Sumit Agrawal
- Department of Biomedical Engineering, The Pennsylvania State University, University Park, PA 16802, USA
| | - Mohamed Osman
- Department of Biomedical Engineering, The Pennsylvania State University, University Park, PA 16802, USA
| | - Josiah Minotto
- Department of Biomedical Engineering, The Pennsylvania State University, University Park, PA 16802, USA
| | - Shubham Mirg
- Department of Biomedical Engineering, The Pennsylvania State University, University Park, PA 16802, USA
| | - Jinyun Liu
- Department of Biomedical Engineering, The Pennsylvania State University, University Park, PA 16802, USA
| | - Ajay Dangi
- Department of Biomedical Engineering, The Pennsylvania State University, University Park, PA 16802, USA
| | - Quyen Tran
- School of Electrical Engineering and Computer Science, The Pennsylvania State University, University Park, PA 16802, USA
| | - Thomas Jackson
- School of Electrical Engineering and Computer Science, The Pennsylvania State University, University Park, PA 16802, USA
| | - Sri-Rajasekhar Kothapalli
- Department of Biomedical Engineering, The Pennsylvania State University, University Park, PA 16802, USA
- Penn State Cancer Institute, The Pennsylvania State University, Hershey, PA 17033, USA
- Graduate Program in Acoustics, The Pennsylvania State University, University Park, PA 16802, USA
| |
Collapse
|
6
|
Yahav G, Weber Y, Duadi H, Pawar S, Fixler D. Classification of fluorescent anisotropy decay based on the distance approach in the frequency domain. OPTICS EXPRESS 2022; 30:6176-6192. [PMID: 35209559 DOI: 10.1364/oe.453108] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/05/2022] [Accepted: 02/01/2022] [Indexed: 06/14/2023]
Abstract
Frequency-domain (FD) fluorometry is a widely utilized tool to probe unique features of complex biological structures, which may serve medical diagnostic purposes. The conventional data analysis approaches used today to extract the fluorescence intensity or fluorescence anisotropy (FA) decay data suffer from several drawbacks and are inherently limited by the characteristics and complexity of the decay models. This paper presents the squared distance (D2) technique, which categorized samples based on the direct frequency response data (FRD) of the FA decay. As such, it improves the classification ability of the FD measurements of the FA decay as it avoids any distortion that results from the challenged translation into time domain data. This paper discusses the potential use of the D2 approach to classify biological systems. Mathematical formulation of D2 technique adjusted to the FRD of the FA decay is described. In addition, it validates the D2 approach using 2 simulated data sets of 6 groups with similar widely and closely spaced FA decay data as well as in experimental data of 4 samples of a fluorophore-solvent (fluorescein-glycerol) system. In the simulations, the classification accuracy was above 95% for all 6 groups. In the experimental data, the classification accuracy was 100%. The D2 approach can help classify samples whose FA decay data are difficult to extract making FA in the FD a realistic diagnostic tool. The D2 approach offers an advanced method for sorting biological samples with differences beyond the practical temporal resolution limit in a reliable and efficient manner based on the FRD of their time-resolved fluorescence measurements thereby achieving better diagnostic quality in a shorter time.
Collapse
|
7
|
Abdolmanafi A, Duong L, Ibrahim R, Dahdah N. Intravascular imaging of coronary artery: Bridging the gap between clinical needs and technical advances. Med Eng Phys 2021; 96:71-80. [PMID: 34565555 DOI: 10.1016/j.medengphy.2021.09.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2020] [Revised: 08/13/2021] [Accepted: 09/13/2021] [Indexed: 12/19/2022]
Abstract
Coronary artery disease is the leading cause of mortality worldwide. Almost seven million deaths are reported each year due to coronary disease. Coronary artery events in the adult are primarily due to atherosclerosis with seventy-five percent of the related mortality caused by plaque rupture. Despite significant progress made to improve intravascular imaging of coronary arteries, there is still a large gap between clinical needs and technical developments. The goal of this review is to identify the gap elements between clinical knowledge and recent advances in the domain of medical image analysis. Efficient image analysis computational models should be designed with respect to the exact clinical needs, and detailed features of the tissues under review. In this review, we discuss the detailed clinical features of the intracoronary plaques for mathematical and biomedical researchers. We emphasize the importance of integrating this clinical knowledge validated by clinicians to investigate the potentially effective models for proper features efficiency in the scope of leveraging the state-of-the-art of coronary image analyses.
Collapse
Affiliation(s)
- Atefeh Abdolmanafi
- Department of Software and IT Engineering, École de Technologie Supérieure, Montréal, Canada; Division of Pediatric Cardiology and Research Center, Centre Hospitalier Universitaire Sainte-Justine, Montréal, Canada.
| | - Luc Duong
- Department of Software and IT Engineering, École de Technologie Supérieure, Montréal, Canada; Division of Pediatric Cardiology and Research Center, Centre Hospitalier Universitaire Sainte-Justine, Montréal, Canada
| | - Ragui Ibrahim
- Division of Cardiology, Hôpital Pierre Boucher, Longueuil, Canada
| | - Nagib Dahdah
- Division of Pediatric Cardiology and Research Center, Centre Hospitalier Universitaire Sainte-Justine, Montréal, Canada
| |
Collapse
|
8
|
Sung JH, Chang JH. Mechanically Rotating Intravascular Ultrasound (IVUS) Transducer: A Review. SENSORS (BASEL, SWITZERLAND) 2021; 21:3907. [PMID: 34198822 PMCID: PMC8201242 DOI: 10.3390/s21113907] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/30/2021] [Revised: 05/31/2021] [Accepted: 06/03/2021] [Indexed: 12/30/2022]
Abstract
Intravascular ultrasound (IVUS) is a valuable imaging modality for the diagnosis of atherosclerosis. It provides useful clinical information, such as lumen size, vessel wall thickness, and plaque composition, by providing a cross-sectional vascular image. For several decades, IVUS has made remarkable progress in improving the accuracy of diagnosing cardiovascular disease that remains the leading cause of death globally. As the quality of IVUS images mainly depends on the performance of the IVUS transducer, various IVUS transducers have been developed. Therefore, in this review, recently developed mechanically rotating IVUS transducers, especially ones exploiting piezoelectric ceramics or single crystals, are discussed. In addition, this review addresses the history and technical challenges in the development of IVUS transducers and the prospects of next-generation IVUS transducers.
Collapse
Affiliation(s)
| | - Jin-Ho Chang
- Department of Information and Communication Engineering, Deagu Gyeongbuk Institute of Science and Technology, Daegu 42988, Korea;
| |
Collapse
|