Sommer KN, Bhurwani MMS, Tutino V, Siddiqui A, Davies J, Snyder K, Levy E, Mokin M, Ionita CN. Use of patient specific 3D printed neurovascular phantoms to simulate mechanical thrombectomy. 3D Print Med 2021; 7:32. [PMID: 34568987 PMCID: PMC8474770 DOI: 10.1186/s41205-021-00122-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2021] [Accepted: 09/11/2021] [Indexed: 01/27/2023] Open
Abstract
BACKGROUND The ability of the patient specific 3D printed neurovascular phantoms to accurately replicate the anatomy and hemodynamics of the chronic neurovascular diseases has been demonstrated by many studies. Acute occurrences, however, may still require further development and investigation and therefore we studied acute ischemic stroke (AIS). The efficacy of endovascular procedures such as mechanical thrombectomy (MT) for the treatment of large vessel occlusion (LVO), can be improved by testing the performance of thrombectomy devices and techniques using patient specific 3D printed neurovascular models. METHODS 3D printed phantoms were connected to a flow loop with physiologically relevant flow conditions, including input flow rate and fluid temperature. A simulated blood clot was introduced into the model and placed in the proximal Middle Cerebral Artery (MCA) region. Clot location, composition, length, and arterial angulation were varied and MTs were simulated using stent retrievers. Device placement relative to the clot and the outcome of the thrombectomy were recorded for each situation. Digital subtraction angiograms (DSA) were captured before and after LVO simulation. Recanalization outcome was evaluated using DSA as either 'no recanalization' or 'recanalization'. Forty-two 3DP neurovascular phantom benchtop experiments were performed. RESULTS Clot angulation within the MCA region had the most significant impact on the MT outcome, with a p-value of 0.016. Other factors such as clot location, clot composition, and clot length correlated weakly with the MT outcome. CONCLUSIONS This project allowed us to gain knowledge of how such characteristics influence thrombectomy success and can be used in making clinical decisions when planning the procedure and selecting specific thrombectomy tools and approaches.
Collapse
Affiliation(s)
- Kelsey N. Sommer
- grid.273335.30000 0004 1936 9887Department of Biomedical Engineering, University at Buffalo, Buffalo, NY 14228 USA ,grid.273335.30000 0004 1936 9887Canon Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY 14208 USA
| | - Mohammad Mahdi Shiraz Bhurwani
- grid.273335.30000 0004 1936 9887Department of Biomedical Engineering, University at Buffalo, Buffalo, NY 14228 USA ,grid.273335.30000 0004 1936 9887Canon Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY 14208 USA
| | - Vincent Tutino
- grid.273335.30000 0004 1936 9887Canon Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY 14208 USA ,grid.273335.30000 0004 1936 9887Department of Neurosurgery, University at Buffalo, Buffalo, NY 14208 USA ,grid.273335.30000 0004 1936 9887Department of Pathology and Anatomical Sciences, University at Buffalo, Buffalo, 14208 USA
| | - Adnan Siddiqui
- grid.273335.30000 0004 1936 9887Canon Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY 14208 USA ,grid.273335.30000 0004 1936 9887Department of Neurosurgery, University at Buffalo, Buffalo, NY 14208 USA
| | - Jason Davies
- grid.273335.30000 0004 1936 9887Canon Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY 14208 USA ,grid.273335.30000 0004 1936 9887Department of Neurosurgery, University at Buffalo, Buffalo, NY 14208 USA ,grid.273335.30000 0004 1936 9887Department of Biomedical Informatics, University at Buffalo, Buffalo, 14208 USA
| | - Kenneth Snyder
- grid.273335.30000 0004 1936 9887Canon Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY 14208 USA ,grid.273335.30000 0004 1936 9887Department of Neurosurgery, University at Buffalo, Buffalo, NY 14208 USA
| | - Elad Levy
- grid.273335.30000 0004 1936 9887Canon Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY 14208 USA ,grid.273335.30000 0004 1936 9887Department of Neurosurgery, University at Buffalo, Buffalo, NY 14208 USA
| | - Maxim Mokin
- grid.170693.a0000 0001 2353 285XDepartment of Neurosurgery and Brain Repair, University of South Florida, Tampa, FL 33620 USA
| | - Ciprian N. Ionita
- grid.273335.30000 0004 1936 9887Department of Biomedical Engineering, University at Buffalo, Buffalo, NY 14228 USA ,grid.273335.30000 0004 1936 9887Canon Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY 14208 USA ,grid.273335.30000 0004 1936 9887Department of Neurosurgery, University at Buffalo, Buffalo, NY 14208 USA
| |
Collapse
|
2
|
Sparks AJ, Smith CM, Allman AB, Senko JL, Meess KM, Ducharme RW, Springer ME, Waqas M, Siddiqui AH. Compliant vascular models 3D printed with the Stratasys J750: a direct characterization of model distensibility using intravascular ultrasound. 3D Print Med 2021; 7:28. [PMID: 34477997 PMCID: PMC8414686 DOI: 10.1186/s41205-021-00114-8] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2020] [Accepted: 07/03/2021] [Indexed: 11/18/2022] Open
Abstract
PURPOSE The purpose of this study is to evaluate biomechanical accuracy of 3D printed anatomical vessels using a material jetting printer (J750, Stratasys, Rehovot, Israel) by measuring distensibility via intravascular ultrasound. MATERIALS AND METHODS The test samples are 3D printed tubes to simulate arterial vessels (aorta, carotid artery, and coronary artery). Each vessel type is defined by design geometry of the vessel inner diameter and wall thickness. Vessel inner diameters are aorta = 30mm, carotid = 7mm, and coronary = 3mm. Vessel wall thickness are aorta = 3mm, carotid = 1.5mm, and coronary = 1mm. Each vessel type was printed in 3 different material options. Material options are user-selected from the J750 printer software graphical user interface as blood vessel wall anatomy elements in 'compliant', 'slightly compliant', and 'rigid' options. Three replicates of each vessel type were printed in each of the three selected material options, for a total of 27 models. The vessels were connected to a flow loop system where pressure was monitored via a pressure wire and cross-sectional area was measured with intravascular ultrasound (IVUS). Distensibility was calculated by comparing the % difference in cross-sectional area vs. pulse pressure to clinical literature values. Target clinical ranges for normal and diseased population distensibility are 10.3-44 % for the aorta, 5.1-10.1 % for carotid artery, and 0.5-6 % for coronary artery. RESULTS Aorta test vessels had the most clinically representative distensibility when printed in user-selected 'compliant' and 'slightly compliant' material. All aorta test vessels of 'compliant' material (n = 3) and 2 of 3 'slightly compliant' vessels evaluated were within target range. Carotid vessels were most clinically represented in distensibility when printed in 'compliant' and 'slightly compliant' material. For carotid test vessels, 2 of 3 'compliant' material samples and 1 of 3 'slightly compliant' material samples were within target range. Coronary arteries were most clinically represented in distensibility when printed in 'slightly compliant' and 'rigid' material. For coronary test vessels, 1 of 3 'slightly compliant' materials and 3 of 3 'rigid' material samples fell within target range. CONCLUSIONS This study suggests that advancements in materials and 3D printing technology introduced with the J750 Digital Anatomy 3D Printer can enable anatomical models with clinically relevant distensibility.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | - Muhammad Waqas
- Department of Neurosurgery, University at Buffalo, State University of New York, 100 High Street, Suite B4, Buffalo, NY, 14203, USA
| | - Adnan H Siddiqui
- The Jacobs Institute, Buffalo, New York, USA.
- Department of Neurosurgery, University at Buffalo, State University of New York, 100 High Street, Suite B4, Buffalo, NY, 14203, USA.
- Canon Stroke and Vascular Research Center, University at Buffalo, State University of New York, Buffalo, New York, USA.
| |
Collapse
|
3
|
Development of Custom Wall-Less Cardiovascular Flow Phantoms with Tissue-Mimicking Gel. Cardiovasc Eng Technol 2021; 13:1-13. [PMID: 34080171 PMCID: PMC8888498 DOI: 10.1007/s13239-021-00546-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/21/2020] [Accepted: 05/12/2021] [Indexed: 10/26/2022]
Abstract
PURPOSE Flow phantoms are used in experimental settings to aid in the simulation of blood flow. Custom geometries are available, but current phantom materials present issues with degradability and/or mimicking the mechanical properties of human tissue. In this study, a method of fabricating custom wall-less flow phantoms from a tissue-mimicking gel using 3D printed inserts is developed. METHODS A 3D blood vessel geometry example of a bifurcated artery model was 3D printed in polyvinyl alcohol, embedded in tissue-mimicking gel, and subsequently dissolved to create a phantom. Uniaxial compression testing was performed to determine the Young's moduli of the five gel types. Angle-independent, ultrasound-based imaging modalities, Vector Flow Imaging (VFI) and Blood Speckle Imaging (BSI), were utilized for flow visualization of a straight channel phantom. RESULTS A wall-less phantom of the bifurcated artery was fabricated with minimal bubbles and continuous flow demonstrated. Additionally, flow was visualized through a straight channel phantom by VFI and BSI. The available gel types are suitable for mimicking a variety of tissue types, including cardiac tissue and blood vessels. CONCLUSION Custom, tissue-mimicking flow phantoms can be fabricated using the developed methodology and have potential for use in a variety of applications, including ultrasound-based imaging methods. This is the first reported use of BSI with an in vitro flow phantom.
Collapse
|
4
|
Sommer KN, Bhurwani MMS, Mokin M, Ionita CN. Evaluation of challenges and limitations of mechanical thrombectomy using 3D printed neurovascular phantoms. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2021; 11601:116010B. [PMID: 34334874 PMCID: PMC8323489 DOI: 10.1117/12.2580962] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
The mechanical thrombectomy (MT) efficacy, for large vessel occlusion (LVO) treatment in patients with stroke, could be improved if better teaching and practicing surgical tools were available. We propose a novel approach that uses 3D printing (3DP) to generate patient anatomical vascular variants for simulation of diverse clinical scenarios of LVO treated with MT. 3DP phantoms were connected to a flow loop with physiologically relevant flow conditions, including input flow rate and fluid temperature. A simulated blood clot was introduced into the model and placed in the Middle Cerebral Artery region. Clot location, composition (hard or soft clot), length, and arterial angulation were varied and MTs were simulated using stent retrievers. Device placement relative to the clot and the outcome of the thrombectomy were recorded for each situation. Angiograms were captured before and after LVO simulation and after the MT. Recanalization outcome was evaluated using the Thrombolysis in Cerebral Infarction (TICI) scale. Forty-two 3DP neurovascular phantom benchtop experiments were performed. Clot mechanical properties, hard versus soft, had the highest impact on the MT outcome, with 18/42 proving to be successful with full or partial clot retrieval. Other factors such as device manufacturer and the tortuosity of the 3DP model correlated weakly with the MT outcome. We demonstrated that 3DP can become a comprehensive tool for teaching and practicing various surgical procedures for MT in LVO patients. This platform can help vascular surgeons understand the endovascular devices limitations and patient vascular geometry challenges, to allow surgical approach optimization.
Collapse
Affiliation(s)
- Kelsey N Sommer
- Department of Biomedical Engineering, University at Buffalo NY 14228,Canon Stroke and Vascular Research Center, University at Buffalo, Buffalo NY 14208
| | - Mohammad Mahdi Shiraz Bhurwani
- Department of Biomedical Engineering, University at Buffalo NY 14228,Canon Stroke and Vascular Research Center, University at Buffalo, Buffalo NY 14208
| | - Maxim Mokin
- Department of Neurosurgery, University of South Florida, Tampa, Florida 33620
| | - Ciprian N Ionita
- Department of Biomedical Engineering, University at Buffalo NY 14228,Canon Stroke and Vascular Research Center, University at Buffalo, Buffalo NY 14208
| |
Collapse
|
5
|
Ali A, Ballard DH, Althobaity W, Christensen A, Geritano M, Ho M, Liacouras P, Matsumoto J, Morris J, Ryan J, Shorti R, Wake N, Rybicki FJ, Sheikh A. Clinical situations for which 3D printing is considered an appropriate representation or extension of data contained in a medical imaging examination: adult cardiac conditions. 3D Print Med 2020; 6:24. [PMID: 32965536 PMCID: PMC7510265 DOI: 10.1186/s41205-020-00078-1] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2020] [Accepted: 09/04/2020] [Indexed: 12/15/2022] Open
Abstract
BACKGROUND Medical 3D printing as a component of care for adults with cardiovascular diseases has expanded dramatically. A writing group composed of the Radiological Society of North America (RSNA) Special Interest Group on 3D Printing (SIG) provides appropriateness criteria for adult cardiac 3D printing indications. METHODS A structured literature search was conducted to identify all relevant articles using 3D printing technology associated with a number of adult cardiac indications, physiologic, and pathologic processes. Each study was vetted by the authors and graded according to published guidelines. RESULTS Evidence-based appropriateness guidelines are provided for the following areas in adult cardiac care; cardiac fundamentals, perioperative and intraoperative care, coronary disease and ischemic heart disease, complications of myocardial infarction, valve disease, cardiac arrhythmias, cardiac neoplasm, cardiac transplant and mechanical circulatory support, heart failure, preventative cardiology, cardiac and pericardial disease and cardiac trauma. CONCLUSIONS Adoption of common clinical standards regarding appropriate use, information and material management, and quality control are needed to ensure the greatest possible clinical benefit from 3D printing. This consensus guideline document, created by the members of the RSNA 3D printing Special Interest Group, will provide a reference for clinical standards of 3D printing for adult cardiac indications.
Collapse
Affiliation(s)
- Arafat Ali
- Department of Radiology, University of Cincinnati Medical Center, Cincinnati, OH, USA.
| | - David H Ballard
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, Saint Louis, MO, USA
| | - Waleed Althobaity
- King Faisal Specialist Hospital and Research Centre, Riyadh, Saudi Arabia
| | - Andy Christensen
- Department of Radiology and The Ottawa Hospital Research Institute, University of Ottawa, Ottawa, ON, Canada
| | | | - Michelle Ho
- Sidney Kimmel Medical College, Thomas Jefferson University, Philadelphia, PA, USA
| | - Peter Liacouras
- 3D Medical Applications Center, Walter Reed National Military Medical Center, Washington, DC, USA
| | - Jane Matsumoto
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| | | | - Justin Ryan
- Rady Children's Hospital, San Diego, CA, USA
| | - Rami Shorti
- Intermountain Healthcare, South Jordan, UT, USA
| | - Nicole Wake
- Department of Radiology, Montefiore Medical Center, Bronx, NY, USA
| | - Frank J Rybicki
- Department of Radiology, University of Cincinnati Medical Center, Cincinnati, OH, USA
| | - Adnan Sheikh
- Department of Radiology and The Ottawa Hospital Research Institute, University of Ottawa, Ottawa, ON, Canada
| | | |
Collapse
|
6
|
Sommer KN, Iyer V, Kumamaru KK, Rava RA, Ionita CN. Method to simulate distal flow resistance in coronary arteries in 3D printed patient specific coronary models. 3D Print Med 2020; 6:19. [PMID: 32761497 PMCID: PMC7410153 DOI: 10.1186/s41205-020-00072-7] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2020] [Accepted: 07/24/2020] [Indexed: 12/23/2022] Open
Abstract
BACKGROUND Three-dimensional printing (3DP) offers a unique opportunity to build flexible vascular patient-specific coronary models for device testing, treatment planning, and physiological simulations. By optimizing the 3DP design to replicate the geometrical and mechanical properties of healthy and diseased arteries, we may improve the relevance of using such models to simulate the hemodynamics of coronary disease. We developed a method to build 3DP patient specific coronary phantoms, which maintain a significant part of the coronary tree, while preserving geometrical accuracy of the atherosclerotic plaques and allows for an adjustable hydraulic resistance. METHODS Coronary computed tomography angiography (CCTA) data was used within Vitrea (Vital Images, Minnetonka, MN) cardiac analysis application for automatic segmentation of the aortic root, Left Anterior Descending (LAD), Left Circumflex (LCX), Right Coronary Artery (RCA), and calcifications. Stereolithographic (STL) files of the vasculature and calcium were imported into Autodesk Meshmixer for 3D model optimization. A base with three chambers was built and interfaced with the phantom to allow fluid collection and independent distal resistance adjustment of the RCA, LAD and LCX and branching arteries. For the 3DP we used Agilus for the arterial wall, VeroClear for the base and a Vero blend for the calcifications, respectively. Each chamber outlet allowed interface with catheters of varying lengths and diameters for simulation of hydraulic resistance of both normal and hyperemic coronary flow conditions. To demonstrate the manufacturing approach appropriateness, models were tested in flow experiments. RESULTS Models were used successfully in flow experiments to simulate normal and hyperemic flow conditions. The inherent mean resistance of the chamber for the LAD, LCX, and RCA, were 1671, 1820, and 591 (dynes ∙ sec/ cm5), respectively. This was negligible when compared with estimates in humans, with the chamber resistance equating to 0.65-5.86%, 1.23-6.86%, and 0.05-1.67% of the coronary resistance for the LAD, LCX, and RCA, respectively at varying flow rates and activity states. Therefore, the chamber served as a means to simulate the compliance of the distal coronary trees and to allow facile coupling with a set of known resistance catheters to simulate various physical activity levels. CONCLUSIONS We have developed a method to create complex 3D printed patient specific coronary models derived from CCTA, which allow adjustable distal capillary bed resistances. This manufacturing approach permits comprehensive coronary model development which may be used for physiologically relevant flow simulations.
Collapse
Affiliation(s)
- Kelsey N Sommer
- Department of Biomedical Engineering, University at Buffalo, Buffalo, NY, USA
- Canon Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY, USA
| | - Vijay Iyer
- University at Buffalo Cardiology, University at Buffalo Jacobs School of Medicine, Buffalo, NY, USA
| | | | - Ryan A Rava
- Department of Biomedical Engineering, University at Buffalo, Buffalo, NY, USA
- Canon Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY, USA
| | - Ciprian N Ionita
- Department of Biomedical Engineering, University at Buffalo, Buffalo, NY, USA.
- Canon Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY, USA.
| |
Collapse
|
7
|
Sommer KN, Shepard LM, Mitsouras D, Iyer V, Angel E, Wilson MF, Rybicki FJ, Kumamaru KK, Sharma UC, Reddy A, Fujimoto S, Ionita CN. Patient-specific 3D-printed coronary models based on coronary computed tomography angiography volumes to investigate flow conditions in coronary artery disease. Biomed Phys Eng Express 2020; 6:045007. [PMID: 33444268 DOI: 10.1088/2057-1976/ab8f6e] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
BACKGROUND 3D printed patient-specific coronary models have the ability to enable repeatable benchtop experiments under controlled blood flow conditions. This approach can be applied to CT-derived patient geometries to emulate coronary flow and related parameters such as Fractional Flow Reserve (FFR). METHODS This study uses 3D printing to compare such benchtop FFR results with a non-invasive CT-FFR research software algorithm and catheter based invasive FFR (I-FFR) measurements. Fifty-two patients with a clinical indication for I-FFR underwent a research Coronary CT Angiography (CCTA) prior to catheterization. CT images were used to measure CT-FFR and to generate patient-specific 3D printed models of the aortic root and three main coronary arteries. Each patient-specific model was connected to a programmable pulsatile pump and benchtop FFR (B-FFR) was derived from pressures measured proximal and distal to coronary stenosis using pressure transducers. B-FFR was measured for two coronary outflow rates ('normal', 250 ml min-1; and 'hyperemic', 500 ml min-1) by adjusting the model's distal coronary resistance. RESULTS Pearson correlations and ROC AUC were calculated using invasive I-FFR as reference. The Pearson correlation factor of CT-FFR and B-FFR-500 was 0.75 and 0.71, respectively. Areas under the ROCs for CT-FFR and B-FFR-500 were 0.80 (95%CI: 0.70-0.87) and 0.81 (95%CI: 0.64-0.91) respectively. CONCLUSION Benchtop flow simulations with 3D printed models provide the capability to measure pressure changes at any location in the model, for ultimately emulating the FFR at several simulated physiological blood flow conditions. CLINICAL TRIAL REGISTRATION https://clinicaltrials.gov/show/NCT03149042.
Collapse
Affiliation(s)
- Kelsey N Sommer
- Department of Biomedical Engineering, University at Buffalo, Buffalo, NY 14228, United States of America. Canon Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY, United States of America
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
8
|
Camara O. Best (and Worst) Practices for Organizing a Challenge on Cardiac Biophysical Models During AI Summer: The CRT-EPiggy19 Challenge. STATISTICAL ATLASES AND COMPUTATIONAL MODELS OF THE HEART. MULTI-SEQUENCE CMR SEGMENTATION, CRT-EPIGGY AND LV FULL QUANTIFICATION CHALLENGES 2020. [DOI: 10.1007/978-3-030-39074-7_35] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
|