1
|
Tuli A, Suresh G, Halder N, Velpandian T. Analysis and remediation of phthalates in aquatic matrices: current perspectives. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2024; 31:23408-23434. [PMID: 38456985 DOI: 10.1007/s11356-024-32670-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/26/2023] [Accepted: 02/23/2024] [Indexed: 03/09/2024]
Abstract
Phthalic acid esters (PAEs) are high production volume chemicals used extensively as plasticizers, to increase the flexibility of the main polymer. They are reported to leach into their surroundings from plastic products and are now a ubiquitous environmental contaminant. Phthalate levels have been determined in several environmental matrices, especially in water. These levels serve as an indicator of plasticizer abuse and plastic pollution, and also serve as a route of exposure to different species including humans. Reports published on effects of different PAEs on experimental models demonstrate their carcinogenic, teratogenic, reproductive, and endocrine disruptive effects. Therefore, regular monitoring and remediation of environmental water samples is essential to ascertain their hazard quotient and daily exposure levels. This review summarises the extraction and detection techniques available for phthalate analysis in water samples such as chromatography, biosensors, immunoassays, and spectroscopy. Current remediation strategies for phthalate removal such as adsorption, advanced oxidation, and microbial degradation have also been highlighted.
Collapse
Affiliation(s)
- Anannya Tuli
- High Precision Bio-Analytical Facility (DST-FIST Sponsored), Ocular Pharmacology and Pharmacy, Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, 110029, India
| | - Gayatri Suresh
- High Precision Bio-Analytical Facility (DST-FIST Sponsored), Ocular Pharmacology and Pharmacy, Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, 110029, India
| | - Nabanita Halder
- High Precision Bio-Analytical Facility (DST-FIST Sponsored), Ocular Pharmacology and Pharmacy, Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, 110029, India
| | - Thirumurthy Velpandian
- High Precision Bio-Analytical Facility (DST-FIST Sponsored), Ocular Pharmacology and Pharmacy, Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, 110029, India.
| |
Collapse
|
2
|
Wu HY, Lin HC, Hung GY, Tu CS, Liu TY, Hong CH, Yu G, Hsu JC. High Sensitivity SERS Substrate of a Few Nanometers Single-Layer Silver Thickness Fabricated by DC Magnetron Sputtering Technology. NANOMATERIALS (BASEL, SWITZERLAND) 2022; 12:2742. [PMID: 36014606 PMCID: PMC9415801 DOI: 10.3390/nano12162742] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/18/2022] [Revised: 08/06/2022] [Accepted: 08/09/2022] [Indexed: 05/10/2023]
Abstract
Surface-enhanced Raman spectroscopy (SERS) is commonly used for super-selective analysis through nanostructured silver layers in the environment, food quality, biomedicine, and materials science. To fabricate a high-sensitivity but a more accessible device of SERS, DC magnetron sputtering technology was used to realize high sensitivity, low cost, a stable deposition rate, and rapid mass production. This study investigated various thicknesses of a silver film ranging from 3.0 to 12.1 nm by field emission scanning electron microscope, X-ray diffraction, and X-ray photoelectron spectroscopy. In the rhodamine 6G (R6G) testing irradiated by a He-Ne laser beam, the analytical enhancement factor (AEF) of 9.35 × 108, the limit of detection (LOD) of 10-8 M, and the relative standard deviation (RSD) of 1.61% were better than the other SERS substrates fabricated by the same DC sputtering process because the results showed that the 6 nm thickness silver layer had the highest sensitivity, stability, and lifetime. The paraquat and acetylcholine analytes were further investigated and high sensitivity was also achievable. The proposed SERS samples were evaluated and stored in a low humidity environment for up to forty weeks, and no spectrum attenuation could be detected. Soon, the proposed technology to fabricate high sensitivity, repeatability, and robust SERS substrate will be an optimized process technology in multiple applications.
Collapse
Affiliation(s)
- Hsing-Yu Wu
- System Manufacturing Center, National Chung-Shan Institute of Science and Technology, New Taipei City 237209, Taiwan
- Center for Astronomical Physics and Engineering, Department of Optics and Photonics, National Central University, Taoyuan City 320317, Taiwan
| | - Hung-Chun Lin
- Department of Physics, Fu Jen Catholic University, New Taipei City 242062, Taiwan
| | - Guan-Yi Hung
- Department of International Ph.D. Program in Innovative Technology of Biomedical Engineering and Medical Devices, Ming Chi University of Technology, New Taipei City 243303, Taiwan
| | - Chi-Shun Tu
- Department of Physics, Fu Jen Catholic University, New Taipei City 242062, Taiwan
| | - Ting-Yu Liu
- Department of Materials Engineering, Ming Chi University of Technology, New Taipei City 243303, Taiwan
| | - Chung-Hung Hong
- Kidney Research Center, Department of Nephrology, Chang Gung Memorial Hospital, College of Medicine, Chang Gung University, 5 Fu-Shing St., Taoyuan 33333, Taiwan
| | - Guoyu Yu
- Department of Engineering and Technology, School of Computing and Engineering, University of Huddersfield, Queensgate, Huddersfield HD1 3DH, UK
| | - Jin-Cherng Hsu
- Department of Physics, Fu Jen Catholic University, New Taipei City 242062, Taiwan
- Graduate Institute of Applied Science and Engineering, Fu Jen Catholic University, New Taipei City 242062, Taiwan
| |
Collapse
|
3
|
San Juan AMT, Chavva SR, Tu D, Tircuit M, Coté G, Mabbott S. Synthesis of SERS-active core-satellite nanoparticles using heterobifunctional PEG linkers. NANOSCALE ADVANCES 2021; 4:258-267. [PMID: 36132957 PMCID: PMC9417690 DOI: 10.1039/d1na00676b] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/08/2021] [Accepted: 11/15/2021] [Indexed: 05/26/2023]
Abstract
Surface-enhanced Raman scattering (SERS) is a sensitive analytical technique capable of magnifying the vibrational intensity of molecules adsorbed onto the surface of metallic nanostructures. Various solution-based SERS-active metallic nanostructures have been designed to generate substantial SERS signal enhancements. However, most of these SERS substrates rely on the chemical aggregation of metallic nanostructures to create strong signals. While this can induce high SERS intensities through plasmonic coupling, most chemically aggregated assemblies suffer from poor signal reproducibility and reduced long-term stability. To overcome these issues, here we report for the first time the synthesis of gold core-satellite nanoparticles (CSNPs) for robust SERS signal generation. The novel CSNP assemblies consist of a 30 nm spherical gold core linked to 18 nm satellite particles via linear heterobifunctional thiol-amine terminated PEG chains. We explore the effects that the varying chain lengths have on SERS hot-spot generation, signal reproducibility and long-term activity. The chain length was varied by using PEGs with different molecular weights (1000 Da, 2000 Da, and 3500 Da). The CSNPs were characterized via UV-Vis spectrophotometry, transmission electron microscopy (TEM), ζ-potential measurements, and lastly SERS measurements. The versatility of the synthesized SERS-active CSNPs was revealed through characterization of optical stability and SERS enhancement at 0, 1, 3, 5, 7 and 14 days.
Collapse
Affiliation(s)
- Angela Michelle T San Juan
- Texas A&M University Health Technologies and Innovations Building, 3006 TAMU College Station Texas 77843 USA
- Department of Biomedical Engineering Emerging Technologies Building 3120 TAMU College Station Texas 77843 USA
| | - Suhash Reddy Chavva
- Texas A&M University Health Technologies and Innovations Building, 3006 TAMU College Station Texas 77843 USA
- Department of Biomedical Engineering Emerging Technologies Building 3120 TAMU College Station Texas 77843 USA
| | - Dandan Tu
- Texas A&M University Health Technologies and Innovations Building, 3006 TAMU College Station Texas 77843 USA
- Department of Biomedical Engineering Emerging Technologies Building 3120 TAMU College Station Texas 77843 USA
| | - Melanie Tircuit
- Texas A&M University Health Technologies and Innovations Building, 3006 TAMU College Station Texas 77843 USA
| | - Gerard Coté
- Texas A&M University Health Technologies and Innovations Building, 3006 TAMU College Station Texas 77843 USA
- Department of Biomedical Engineering Emerging Technologies Building 3120 TAMU College Station Texas 77843 USA
| | - Samuel Mabbott
- Texas A&M University Health Technologies and Innovations Building, 3006 TAMU College Station Texas 77843 USA
- Department of Biomedical Engineering Emerging Technologies Building 3120 TAMU College Station Texas 77843 USA
| |
Collapse
|
4
|
Farrell ME, Strobbia P, Pellegrino PM, Cullum B. Surface regeneration and signal increase in surface-enhanced Raman scattering substrates. APPLIED OPTICS 2017; 56:B198-B213. [PMID: 28157898 DOI: 10.1364/ao.56.00b198] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Regenerated surface-enhanced Raman scattering (SERS) substrates allow users the ability to not only reuse sensing surfaces, but also tailor them to the sensing application needs (wavelength of the available laser, plasmon band matching). In this review, we discuss the development of SERS substrates for response to emerging threats and some of our collaborative efforts to improve on the use of commercially available substrate surfaces. Thus, we are able to extend the use of these substrates to broader Army needs (like emerging threat response).
Collapse
|