1
|
Harada T, Sasaki T, Ishii H, Takemoto S, Hisamatsu Y, Saito H, Yoneshima Y, Komiya K, Kashiwabara K, Naoki K, Ogawa T, Takeoka H, Saruwatari K, Ito K, Tsuchiya-Kawano Y, Mizuno K, Shimose T, Shioyama Y, Okamoto I. A phase II study of weekly carboplatin and concurrent radiotherapy in older adults with locally advanced non-small cell lung cancer (LOGIK1902). Thorac Cancer 2024. [PMID: 39245951 DOI: 10.1111/1759-7714.15444] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2024] [Revised: 08/18/2024] [Accepted: 08/24/2024] [Indexed: 09/10/2024] Open
Abstract
BACKGROUND Concurrent chemoradiotherapy is the standard therapy for locally advanced non-small cell lung cancer (NSCLC). However, there is little evidence supporting its use in older adults. Low-dose daily carboplatin combined with thoracic radiotherapy is considered a standard regimen for this population. To establish a simple and feasible carboplatin administration method, we conducted a study of weekly carboplatin and concurrent radiotherapy for older adults with locally advanced NSCLC. METHODS This prospective, single-arm, multicenter, phase II clinical trial included patients aged ≥75 years with unresectable stage III NSCLC and Eastern Cooperative Oncology Group performance status 0-1. Patients received chemoradiotherapy (60 Gy/30 fractions plus concurrent weekly carboplatin at an area under curve of 2 mg mL-1 min-1). The primary endpoint was the overall response rate (ORR). Key secondary endpoints included progression-free survival (PFS), overall survival (OS), and safety. RESULTS From July 2020 to June 2022, 37 patients were enrolled from 15 institutions, and 36 patients were evaluable for efficacy and safety. The ORR was 63.9% (95% confidence interval [CI] = 47.6-77.5). Median PFS was 14.6 months (95% CI = 9.1-18.1). Median OS was 25.5 months (95% CI = 17.4-not reached). Grade 4 leucopenia, neutropenia, and thrombocytopenia were observed in one patient (2.8%) each. CONCLUSION Weekly carboplatin and concurrent radiation therapy was safe in older adults with locally advanced NSCLC, and promising activity was observed.
Collapse
Affiliation(s)
- Taishi Harada
- Department of Respiratory Medicine, Japan Community Healthcare Organization Kyushu Hospital, Kitakyusyu, Japan
| | - Tomonari Sasaki
- Department of Radiation Oncology, Iizuka Hospital, Iizuka, Japan
| | - Hidenobu Ishii
- Division of Respirology, Neurology, and Rheumatology, Department of Internal Medicine, Kurume University School of Medicine, Kurume, Japan
| | - Shinnosuke Takemoto
- Department of Respiratory Medicine, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan
| | - Yasushi Hisamatsu
- Department of Thoracic Oncology, Oita Prefectural Hospital, Oita, Japan
| | - Haruhiro Saito
- Department of Thoracic Oncology, Kanagawa Cancer Center, Yokohama, Japan
| | - Yasuto Yoneshima
- Department of Respiratory Medicine, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Kazutoshi Komiya
- Department of Respiratory Medicine, National Hospital Organization Ureshino Medical Center, Ureshino, Japan
| | - Kosuke Kashiwabara
- Department of Respiratory Medicine, Kumamoto Regional Medical Center, Kumamoto, Japan
| | - Katsuhiko Naoki
- Department of Respiratory Medicine, Kitasato University School of Medicine, Sagamihara, Japan
| | - Tomohiro Ogawa
- Department of Respiratory Medicine, Saiseikai Fukuoka General Hospital, Fukuoka, Japan
| | - Hiroaki Takeoka
- Department of Respiratory Medicine, NHO Kyushu Medical Center, Fukuoka, Japan
| | - Koichi Saruwatari
- Department of Respiratory Medicine, Kumamoto University Hospital, Kumamoto, Japan
| | - Kensaku Ito
- Department of Thoracic Oncology, NHO Kyushu Cancer Center, Fukuoka, Japan
| | - Yuko Tsuchiya-Kawano
- Department of Respiratory Medicine, Kitakyushu Municipal Medical Center, Kitakyushu, Japan
| | - Keiko Mizuno
- Department of Pulmonary Medicine, Graduate School of Medical and Dental Sciences, Kagoshima University, Kagoshima, Japan
| | - Takayuki Shimose
- Department of Statistics and Data Center, Clinical Research Support Center Kyushu, Fukuoka, Japan
| | | | - Isamu Okamoto
- Department of Respiratory Medicine, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| |
Collapse
|
2
|
Azhar D, Gul A, Javid MA, Hussain MM, Shehzadi NN. Evaluation of scanning resolution, detector choice and detector orientation to be used for accurate and time-efficient commissioning of a 6MV clinical linear accelerator. RADIATION AND ENVIRONMENTAL BIOPHYSICS 2023; 62:83-96. [PMID: 36520198 DOI: 10.1007/s00411-022-01008-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/12/2022] [Accepted: 12/03/2022] [Indexed: 06/17/2023]
Abstract
The present study is aimed at exploring different scanning parameters, detectors and their orientations for time-efficient and accurate commissioning of a 6 MV clinical linear accelerator (LINAC). Beam profiles and percentage depth dose (PDD) curves were measured with a PTW dosimetry diode, a PTW Semiflex and a PinPoint ion chamber in different orientations. To acquire beam data, equidistant (step size of 0.5 mm, 1 mm, 2 mm and 3 mm) and fanline (step size of 2-0.5 mm, 2-1 mm, 3-0.5 mm and 3-1 mm) scanning modes were employed and data measurement time was recorded. Scan time per measurement point was also varied (0.2 s, 0.5 s and 1.0 s) to investigate its effect on the accuracy and acquisition time of beam data. Accuracy of the measured data was analyzed on the basis of the variation between measured data and data modeled by a treatment planning system. Beam profiles (particularly in penumbra region) were found to be sensitive to variation in scanning resolution and showed an improved accuracy with decrease in step size, while PDD curves were affected negligibly. The accuracy of beam data obtained with the PTW dosimetry diode and the PinPoint ion chamber was higher than those obtained with the PTW Semiflex ion chamber for small fields (2 × 2 cm2 and 3 × 3 cm2). However, the response of the PTW diode and the PinPoint ion chamber was significantly indifferent in these fields. Furthermore, axial orientation of the PTW Semiflex ion chamber improved accuracy of profiles and PDDs as compared to radial orientation, while such a difference was not significant for the PinPoint ion chamber. It is concluded that a scan time of 0.2 s/point with a fanline scanning resolution of 2-1 mm for beam profiles and 3 mm for PDDs are most favorable in terms of accuracy and time efficiency. For small fields (2 × 2 cm2 and 3 × 3 cm2), a PinPoint ion chamber in radial orientation or a dosimetry diode in axial orientation are recommended for both beam profiles and PDDs. If a PinPoint ion chamber and a PTW dosimetry diode are not available, a Semiflex ion chamber in axial orientation may be used for small fields.
Collapse
Affiliation(s)
- Deeba Azhar
- Department of Basic Sciences, University of Engineering and Technology, Taxila, 47080, Pakistan
| | - Attia Gul
- Institute of Nuclear Medicine, Oncology and Radiotherapy (INOR), Abbottabad, 22010, Pakistan.
| | - Muhamad Arshad Javid
- Institute of Physics, Islamia University of Bahawalpur, Bahawalpur, 63100, Pakistan
| | | | | |
Collapse
|
3
|
The determination of virtual source position using convergent anti-trigonometric functions (arcCOS and arcSIN) method for scanning-passive scatter beam in carbon ion therapy. POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING 2023. [DOI: 10.2478/pjmpe-2023-0002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Abstract
Introduction: We developed a convergent trigonometric functions technique (arcCOS, arcSIN) capable of dealing with the virtual source position delivered by different carbon ion energies from the pattern of scanning-passive scatter beam in this study.
Materials and Methods: A home-made large-format CMOS sensor and Gaf Chromic EBT3 films were used for the virtual source position measurement. The Gaf films were embedded in a self-designed rectangular plastic frame to tighten the films and set up on a treatment couch for irradiation in the air with the film perpendicular to the carbon ion beam at the nominal source-axis-distance (SAD) as well as upstream and downstream from the SAD. The horizontal carbon ion beam with 5 energies at a machine opening field size was carried out in this study. The virtual source position was determined with a convergent arcCOS and arcSIN methods and compared with the linear regression by back-projecting the FWHM to zero at a distance upstream from the various source-film-distance.
Results: The film FWHM measurement error of 0.5 mm (the large-format CMOS detectors was in pixel, a pixel equals 0.5 mm) leads to 1×10-3% deviation of α(cACOS and cASIN) at every assumed virtual source position. The overall uncertainty for the reproducibility of the calculated virtual source position by the assumed t in the vertical and horizontal directions amounts to 0.1%. The errors of calculated virtual source position by assumed t with back projecting FWHM to zero methods were within 1.1 ± 0.001, p = 0.033. The distance of virtual source positions is decreased from SAD with high to low energy.
Conclusion: We have developed a technique capable of dealing with the virtual source position with a convergent arcCOS and arcSIN methods to avoid any manual measurement mistakes in scanning-passive scatter carbon ion beam. The method for investigating the virtual source position in the carbon ion beam in this study can also be used for external electrons and the proton.
Collapse
|
4
|
Characterization and implementation of the L-alanine detector for quality control of lung SBRT treatments with the VMAT technique. JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES 2022. [DOI: 10.1016/j.jrras.2022.01.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
5
|
Cheung MLM, Kan MWK, Yeung VTY, Poon DMC, Kam MKM, Lee LKY, Chan ATC. The radiobiological effect of using Acuros XB vs anisotropic analytical algorithm on hepatocellular carcinoma stereotactic body radiation therapy. Med Dosim 2022; 47:161-165. [PMID: 35241348 DOI: 10.1016/j.meddos.2022.01.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2021] [Revised: 01/23/2022] [Accepted: 01/31/2022] [Indexed: 11/26/2022]
Abstract
The purpose of this work was to study the radiobiological effect of using Acuros XB (AXB) vs Analytic Anisotropic Algorithm (AAA) on hepatocellular carcinoma (HCC) stereotactic body radiation therapy (SBRT). Seventy SBRT volumetric modulated arc therapy (VMAT) plans for HCC were calculated using AAA and AXB respectively with the same treatment parameters. Published tumor control probability (TCP) and normal tissue complication probability (NTCP) models were used to quantify the effect of dosimetric difference between AAA and AXB on TCP, NTCP and uncomplicated tumor control probability (UTCP). There was an average decrease of 2.5% in 6-month TCP. Normal liver has the largest average decrease in NTCP which was 59.7%. Bowels followed with 26.6% average decrease in NTCP. Duodenum, stomach and esophagus had 10.2%, 5.1%, and 4.3% average decrease in NTCP. There was an average decrease of 1.8% and up to 7.2% in 6-month UTCP. There was an overall decrease in TCP, NTCP, and UTCP for HCC SBRT plans calculated using AXB compared to AAA which could be clinically significant.
Collapse
Affiliation(s)
- Michael L M Cheung
- Department of Clinical Oncology, Prince of Wales Hospital, Hong Kong SAR, China; State Key Laboratory of Translational Oncology, The Chinese University of Hong Kong, Hong Kong SAR, China.
| | - Monica W K Kan
- Department of Clinical Oncology, Prince of Wales Hospital, Hong Kong SAR, China; State Key Laboratory of Translational Oncology, The Chinese University of Hong Kong, Hong Kong SAR, China
| | - Vanessa T Y Yeung
- Department of Clinical Oncology, Prince of Wales Hospital, Hong Kong SAR, China; State Key Laboratory of Translational Oncology, The Chinese University of Hong Kong, Hong Kong SAR, China
| | - Darren M C Poon
- State Key Laboratory of Translational Oncology, The Chinese University of Hong Kong, Hong Kong SAR, China
| | - Michael K M Kam
- State Key Laboratory of Translational Oncology, The Chinese University of Hong Kong, Hong Kong SAR, China
| | - Louis K Y Lee
- State Key Laboratory of Translational Oncology, The Chinese University of Hong Kong, Hong Kong SAR, China
| | - Anthony T C Chan
- Department of Clinical Oncology, Prince of Wales Hospital, Hong Kong SAR, China; State Key Laboratory of Translational Oncology, The Chinese University of Hong Kong, Hong Kong SAR, China
| |
Collapse
|
6
|
Dose calculation accuracy for photon small fields in treatment planning systems with comparison by Monte Carlo simulations. POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING 2021. [DOI: 10.2478/pjmpe-2021-0022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Abstract
Purpose: Advanced radiation therapy techniques use small fields in treatment planning and delivery. Small fields have the advantage of more accurate dose delivery, but with the cost of some complications in dosimetry. Different dose calculation algorithms imported in various treatment planning systems (TPSs) which each of them has different accuracy. Monte Carlo (MC) simulation has been reported as one of the accurate methods for calculating dose distribution in radiation therapy. The aim of this study was the evaluation of TPS dose calculation algorithms in small fields against 2 MC codes.
Methods: A linac head was simulated in 2 MC codes, MCNPX, and GATE. Then three small fields (0.5×0.5, 1×1 and 1.5×1.5 cm2) were simulated with 2 MC codes, and also these fields were planned with different dose calculation algorithms in Isogray and Monaco TPS. PDDs and lateral dose profiles were extracted and compared between MC simulations and dose calculation algorithms.
Results: For 0.5×0.5 cm2 field mean differences in PDDs with MCNPX were 2.28, 4.6, 5.3, and 7.4% and with GATE were -0.29, 2.3, 3 and 5% for CCC, superposition, FFT and Clarkson algorithms respectively. For 1×1 cm2 field mean differences in PDDs with MCNPX were 1.58, 0.6, 1.1 and 1.4% and with GATE were 0.77, 0.1, 0.6 and 0.9% for CCC, superposition, FFT and Clarkson algorithms respectively. For 1.5×1.5 cm2 field mean differences in PDDs with MCNPX were 0.82, 0.4, 0.6 and -0.4% and with GATE were 2.38, 2.5, 2.7 and 1.7% for CCC, superposition, FFT and Clarkson algorithms respectively.
Conclusions: Different dose calculation algorithms were evaluated and compared with MC simulation in small fields. Mean differences with MC simulation decreased with the increase of field sizes for all algorithms.
Collapse
|
7
|
Bajwa S, Gul A, Ahmed S, Kakakhel MB. Monte Carlo commissioning of radiotherapy LINAC-Introducing an improved methodology. Rep Pract Oncol Radiother 2020; 25:720-724. [PMID: 32684860 DOI: 10.1016/j.rpor.2020.06.009] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2020] [Revised: 05/18/2020] [Accepted: 06/23/2020] [Indexed: 11/15/2022] Open
Abstract
Purpose Monte Carlo (MC) commissioning of medical linear accelerator (LINAC) is a time-consuming process involving a comparison between measured and simulated cross beam/lateral profiles and percentage depth doses (PDDs) for various field sizes. An agreement between these two data sets is sought by trial and error method while varying the incident electron beam parameters, such as electron beam energy or width, etc. This study aims to improve the efficiency of MC commissioning of a LINAC by assessing the feasibility of using a limited number of simulated PDDs. Materials and methods Using EGSnrc codes, a Varian Clinac 2100 unit has been commissioned for 6 MV photon beam, and a methodology has been proposed to identify the incident electron beam parameters in a speedier fashion. Impact of voxel size in 3-dimensions and cost functions used for comparison of the measured and simulated data have been investigated along with the role of interpolation. Results A voxel size of 1 × 1×0.5 cm3 has been identified as suitable for accurate and fast commissioning of the LIANC. The optimum number of simulated PDDs (required for further interpolation) has been found to be five. Conclusion The present study suggests that PDDs alone at times can be insufficient for an unambiguous commissioning process and should be supported by including the lateral beam profiles in the process.
Collapse
Affiliation(s)
- Saqib Bajwa
- Department of Physics & Applied Mathematics, Pakistan Institute of Engineering & Applied Sciences (PIEAS), Nilore, Islamabad, Pakistan
| | - Attia Gul
- Department of Physics & Applied Mathematics, Pakistan Institute of Engineering & Applied Sciences (PIEAS), Nilore, Islamabad, Pakistan
| | - Shahbaz Ahmed
- Wayne State University School of Medicine Gershenson Radiation Oncology Center Karmanos Cancer Institute, 4100 John R, Detroit, MI 48201.,Department of Physics & Applied Mathematics, Pakistan Institute of Engineering & Applied Sciences (PIEAS), Nilore, Islamabad, Pakistan
| | - Muhammad B Kakakhel
- Department of Physics & Applied Mathematics, Pakistan Institute of Engineering & Applied Sciences (PIEAS), Nilore, Islamabad, Pakistan
| |
Collapse
|
8
|
Chung JH, Chun M, Kim JI, Park JM, Shin KH. Three-dimensional versus four-dimensional dose calculation for breast intensity-modulated radiation therapy. Br J Radiol 2020; 93:20200047. [PMID: 32187503 PMCID: PMC10993216 DOI: 10.1259/bjr.20200047] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2020] [Revised: 03/05/2020] [Accepted: 03/13/2020] [Indexed: 12/25/2022] Open
Abstract
OBJECTIVE To analyze the effect of intra- and interfractional motion during breast intensity modulated radiation therapy (IMRT) by calculating dose distribution based on four-dimensional computed tomography (4DCT). METHODS 20 patients diagnosed with left breast cancer were enrolled. Three-dimensional CT (3DCT) along with 10 phases of 4DCT were collected for each patient, with target volumes independently delineated on both 3DCT and all phases of 4DCT. IMRT plans were generated based on 3DCT (43.2 Gy in 16 fractions). The plan parameters for each segment were split into phases based on time duration estimates for each respiratory phase, with phase-specific dose distributions calculated and summated (4D-calculated dose). The procedure is repeated for 16 fractionations by randomly allocating starting phase using random-number generation to simulate interfractional discrepancy caused by different starting phase. Comparisons of plan quality between the original and 4D-calculated doses were analyzed. RESULTS There was a significant distortion in 4D-calculated dose induced by respiratory motion in terms of conformity and homogeneity index compared to those of the original 3D plan. Mean doses of the heart and the ipsilateral lung were significantly higher in the 4D-calculated doses compared to those of the original 3D plan (0.34 Gy, p = 0.010 and 0.59 Gy, p < 0.001), respectively). The mean internal mammary lymph node (IMN) dose was significantly greater in the 4D-calculated plan, compared to the original 3D plan (1.42 Gy, p < 0.001). CONCLUSIONS IMN doses should be optimized during the dose-calculation for the free-breathing left breast IMRT. ADVANCES IN KNOWLEDGE The interplay effect between respiratory motion and multileaf collimator modulation caused discrepancies in dose distribution, particularly in IMN.
Collapse
Affiliation(s)
- Joo-Hyun Chung
- Department of Radiation Oncology, Seoul National University
Hospital, Seoul, Republic
of Korea
| | - Minsoo Chun
- Department of Radiation Oncology, Seoul National University
Hospital, Seoul, Republic
of Korea
- Biomedical Research Institute, Seoul National University
College of Medicine, Seoul,
Republic of Korea
- Institute of Radiation Medicine, Seoul National University
Medical Research Center, Seoul,
Republic of Korea
| | - Jung-in Kim
- Department of Radiation Oncology, Seoul National University
Hospital, Seoul, Republic
of Korea
- Biomedical Research Institute, Seoul National University
College of Medicine, Seoul,
Republic of Korea
- Institute of Radiation Medicine, Seoul National University
Medical Research Center, Seoul,
Republic of Korea
| | - Jong Min Park
- Department of Radiation Oncology, Seoul National University
Hospital, Seoul, Republic
of Korea
- Biomedical Research Institute, Seoul National University
College of Medicine, Seoul,
Republic of Korea
- Institute of Radiation Medicine, Seoul National University
Medical Research Center, Seoul,
Republic of Korea
- Robotics Research Laboratory for Extreme Environments, Advanced
Institutes of Convergence Technology,
Suwon, Republic of Korea
| | - Kyung Hwan Shin
- Department of Radiation Oncology, Seoul National University
Hospital, Seoul, Republic
of Korea
- Biomedical Research Institute, Seoul National University
College of Medicine, Seoul,
Republic of Korea
- Institute of Radiation Medicine, Seoul National University
Medical Research Center, Seoul,
Republic of Korea
| |
Collapse
|
9
|
Mullins J, Renaud MA, Heng V, Ruo R, DeBlois F, Seuntjens J. Trajectory-based VMAT for cranial targets with delivery at shortened SAD. Med Phys 2020; 47:3103-3112. [PMID: 32198933 DOI: 10.1002/mp.14151] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2019] [Revised: 03/04/2020] [Accepted: 03/07/2020] [Indexed: 01/17/2023] Open
Abstract
INTRODUCTION Trajectory-based volumetric modulated arc therapy (tr-VMAT) treatment plans enable the option for noncoplanar delivery yielding steeper dose gradients and increased sparing of critical structures compared to conventional treatment plans. The addition of translational couch motion to shorten the effective source-to-axis distance (SAD) may result in improved delivery precision and an increased effective dose rate. In this work, tr-VMAT treatment plans using a noncoplanar "baseball stitch" trajectory were implemented, applied to patients presented with cranial targets, and compared to the clinical treatment plans. METHODS A treatment planning workflow was implemented: (a) beamlet doses were calculated for control points defined along a baseball stitch trajectory using a collapsed-cone convolution-superposition algorithm; (b) VMAT treatment plans were optimized using the column generation approach; (c) a final dose distribution was calculated in Varian Eclipse using the analytical anisotropic algorithm by importing the optimized treatment plan parameters. Tr-VMAT plans were optimized for ten patients presented with cranial targets at both standard and shortened SAD, and compared to the clinical treatment plans through isodose distributions, dose-volume histograms, and dosimetric indices. The control point specifications of the optimized tr-VMAT plans were used to estimate the delivery time. RESULTS The optimized tr-VMAT plans with both shortened and standard SAD delivery yielded a comparable plan quality to the clinical treatment plans. A statistically significant benefit was observed for dose gradient index and monitor unit efficiency for shortened SAD tr-VMAT plans, while improved target volume conformity was observed for the clinical treatment plan (P ≤ 0.05). A clear dosimetric benefit was not demonstrated between tr-VMAT delivery at shortened SAD compared to standard SAD, but shortened SAD delivery yielded a fraction size-dependent reduction in the estimated delivery time. CONCLUSION The implementation of "baseball stitch" tr-VMAT treatment plans to patients presented with cranial targets demonstrated comparable plan quality to clinical treatment plans. The delivery at shortened SAD produced a fraction size-dependent decrease in estimated delivery time.
Collapse
Affiliation(s)
- Joel Mullins
- Department of Physics & Medical Physics Unit, McGill University, Montréal, QC, H4A 3J1, Canada
| | - Marc-André Renaud
- Department of Mathematics and Industrial Engineering, Polytechnique Montréal, Montréal, QC, H3T 1J4, Canada
| | - Veng Heng
- Department of Physics & Medical Physics Unit, McGill University, Montréal, QC, H4A 3J1, Canada
| | - Russell Ruo
- Medical Physics Unit, McGill University Health Centre, Montréal, QC, H4A 3J1, Canada
| | - François DeBlois
- Centre Hospitalier de l'Université de Montréal & Département de Physique, Université de Montréal, Montréal, QC, H2X 3E4, Canada.,McGill University, Montréal, QC, H4A 3J1, Canada
| | - Jan Seuntjens
- Medical Physics Unit, McGill University & Research Institute of the McGill University Health Centre, Montréal, QC, H4A 3J1, Canada
| |
Collapse
|
10
|
Martins JC, Saxena R, Neppl S, Alhazmi A, Reiner M, Veloza S, Belka C, Parodi K. Optimization of Phase Space files from clinical linear accelerators. Phys Med 2019; 64:54-68. [PMID: 31515036 DOI: 10.1016/j.ejmp.2019.06.007] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/07/2018] [Revised: 06/05/2019] [Accepted: 06/15/2019] [Indexed: 10/26/2022] Open
Abstract
This work proposes a methodology to produce an optimized phase-space (PhSp) for the Elekta Synergy linac by tuning the energy and direction of particles inside the 6-MV Elekta Precise PhSp, provided by the International Atomic Energy Agency (IAEA), for Monte Carlo (MC) simulations. First, the energies of the particles emerging from the original PhSp were increased by different factors, producing new PhSps. Percentage depth dose (PDD) profiles were simulated and compared to measured data from a Synergy linac for 6-MV photon beam. This process was repeated until a minimum difference was reached. Particles' directions were then manipulated following identified correlations to lateral profiles, resulting in two distinct perturbation factors based on inline and crossline profiles. Both factors were merged into one single optimal factor. For energy optimization, an increase of 0.32 MeV applied to all particles inside the original PhSp, but to 0.511 MeV annihilation photons, provided the best results. The direction optimization factor was the combination of the individual factors for inline (0.605%) and crossline (0.051%). The agreement between measured and simulated profiles, when using the optimized PhSp, improved considerably in comparison to simulations performed with the original IAEA PhSp. For all fields and depths analyzed, the discrepancies for PDD, inline and crossline profiles dropped from 11.2%, 15.7% and 27.5% to under 1.4%, 4.7% and 13.2%, respectively. The optimized PhSp should not replace the full linac modelling, however it offers an alternative for MC dose calculations when neither geometric details nor validated IAEA PhSp are available to the user.
Collapse
Affiliation(s)
- Juliana Cristina Martins
- Department of Medical Physics, Faculty of Physics, Ludwig-Maximilians-Universität München, Am Coulombwall 1, 85748 Garching b. München, Germany.
| | - Rangoli Saxena
- Department of Medical Physics, Faculty of Physics, Ludwig-Maximilians-Universität München, Am Coulombwall 1, 85748 Garching b. München, Germany.
| | - Sebastian Neppl
- Department of Radiation Oncology, University Hospital, LMU Munich, Marchioninistraße15, 81377 Munich, Germany.
| | - Abdulaziz Alhazmi
- Department of Medical Physics, Faculty of Physics, Ludwig-Maximilians-Universität München, Am Coulombwall 1, 85748 Garching b. München, Germany.
| | - Michael Reiner
- Department of Radiation Oncology, University Hospital, LMU Munich, Marchioninistraße15, 81377 Munich, Germany.
| | - Stella Veloza
- Department of Medical Physics, Faculty of Physics, Ludwig-Maximilians-Universität München, Am Coulombwall 1, 85748 Garching b. München, Germany.
| | - Claus Belka
- Department of Radiation Oncology, University Hospital, LMU Munich, Marchioninistraße15, 81377 Munich, Germany; German Cancer Consortium (DKTK), Pettenkoferstraße 8a, 80336 Munich, Germany.
| | - Katia Parodi
- Department of Medical Physics, Faculty of Physics, Ludwig-Maximilians-Universität München, Am Coulombwall 1, 85748 Garching b. München, Germany.
| |
Collapse
|
11
|
Najafzadeh M, Nickfarjam A, Jabbari K, Markel D, Chow JCL, Takabi FS. Dosimetric verification of lung phantom calculated by collapsed cone convolution: A Monte Carlo and experimental evaluation. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2019; 27:161-175. [PMID: 30614811 DOI: 10.3233/xst-180425] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
OBJECTIVE To evaluate the dose calculation accuracy in the Prowess Panther treatment planning system (TPS) using the collapsed cone convolution (CCC) algorithm. METHODS The BEAMnrc Monte Carlo (MC) package was used to predict the dose distribution of photon beams produced by the Oncor® linear accelerator (linac). The MC model of an 18 MV photon beam was verified by measurement using a p-type diode dosimeter. Percent depth dose (PDD) and dose profiles were used for comparison based on three field sizes: 5×5, 10×10, and 20×20cm2. The accuracy of the CCC dosimetry was also evaluated using a plan composed of a simple parallel-opposed field (11×16cm2) in a lung phantom comprised of four tissue simulating media namely, lung, soft tissue, bone and spinal cord. The CCC dose calculation accuracy was evaluated by MC simulation and measurements according to the dose difference and 3D gamma analysis. Gamma analysis was carried out through comparison of the Monte Carlo simulation and the TPS calculated dose. RESULTS Compared to the dosimetric results measured by the Farmer chamber, the CCC algorithm underestimated dose in the planning target volume (PTV), right lung and lung-tissue interface regions by about -0.11%, -1.6 %, and -2.9%, respectively. Moreover, the CCC algorithm underestimated the dose at the PTV, right lung and lung-tissue interface regions in the order of -0.34%, -0.4% and -3.5%, respectively, when compared to the MC simulation. Gamma analysis results showed that the passing rates within the PTV and heterogeneous region were above 59% and 76%. For the right lung and spinal cord, the passing rates were above 80% for all gamma criteria. CONCLUSIONS This study demonstrates that the CCC algorithm has potential to calculate dose with sufficient accuracy for 3D conformal radiotherapy within the thorax where a significant amount of tissue heterogeneity exists.
Collapse
Affiliation(s)
- Milad Najafzadeh
- Department of Medical Physics, Faculty of Medicine, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
- Department of Radiology, Faculty of Para-Medicine, Hormozgan University of Medical Sciences, Bandare-Abbas, Iran
| | - Abolfzal Nickfarjam
- Department of Medical Physics, Faculty of Medicine, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
- Radiotherapy Research Center, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
| | - Keyvan Jabbari
- Department of Medical Physics, Faculty of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
| | - Daniel Markel
- Department of Radiation Oncology, University of Toronto and Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, ON, Canada
| | - James C L Chow
- Department of Radiation Oncology, University of Toronto and Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, ON, Canada
| | - Fatemeh Shirani Takabi
- Department of Medical Physics, Faculty of Medicine, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
| |
Collapse
|
12
|
Comparative study between Acuros XB algorithm and Anisotropic Analytical Algorithm in the case of heterogeneity for the treatment of lung cancer. POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING 2018. [DOI: 10.2478/pjmpe-2018-0016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Abstract
The aim of this study was to investigate the impact of heterogeneity on the dose calculation for two algorithms implemented in the TPS “Analytical Anisotropic Algorithm (AAA) and Acuros XB” and validated the use of Acuros XB algorithm in clinical routine. First, we compare the dose calculated by these algorithms and the dose measured at the given point P, which is found after heterogeneity insert. Second, we extend our work on clinical cases that present a complex heterogeneity. By evaluating the impact of the choice of the algorithm on the dose coverage of the tumor, and the dose received by the organs at risk for 20 patients affected by lung cancer.
The result of our phantom study showed a good agreement with several studies that showed the superiority of the Acuros XB over the AAA in predicting dose when it concerns heterogeneous media. The treatment plans for 20 lung cancers were calculated by two algorithms AAA and Acuros XB, the results show a statistical significant difference between algorithms for Homogeneity Index and the maximum dose of planning target volume (HI: 0.11±0.01 vs 0.05±0.01 p = 0.04; Dmax: 69.30±3.12 vs 68.51±2.64 p = 0.02). Instead, no statistically significant difference was observed for conformity index CI and mean dose (CI: 0.98±0.18 vs 0.99±0.14 p = 0.33; Dmean: 66.3±0.65 vs 66.10 ±0.61 p = 0.54). For organs at risk, the maximum dose for spinal cord, mean dose and D37 % of lung minus GTV (dose receiving 37% of lung volume) were found to be lower for AAA plans than Acuros XB and the differences were statistically significant (p<0.05). For the heart D33% and D67% were found to be higher for AAA plans than Acuros XB and the differences were statistically significant (p<0.05), but No difference was observed for D100% of the heart.
The use of the AXB algorithm is suitable in the case of presence of heterogeneity, because it allows to have a better accuracy close to the Monte Carlo calculation.
Collapse
|
13
|
A comparison of Monte Carlo, anisotropic analytical algorithm (AAA) and Acuros XB algorithms in assessing dosimetric perturbations during enhanced dynamic wedged radiotherapy deliveries in heterogeneous media. JOURNAL OF RADIOTHERAPY IN PRACTICE 2018. [DOI: 10.1017/s1460396918000262] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AbstractBackgroundA comparison of anisotropic analytical algorithm (AAA) and Acuros XB (AXB) dose calculation algorithms with Electron Gamma Shower (EGSnrc) Monte Carlo (MC) for modelling lung and bone heterogeneities encountered during enhanced dynamic wedged (EDWs) radiotherapy dose deliveries was carried out.Materials and methodsIn three heterogenous slab phantoms: water–bone, lung–bone and bone–lung, wedged percentage depth doses with EGSnrc, AAA and AXB algorithms for 6 MV photons for various field sizes (5×5, 10×10 and 20×20 cm2) and EDW angles (15°, 30°, 45° and 60°) have been scored.ResultsFor all the scenarios, AAA and AXB results were within ±1% of the MC in the pre-inhomogeneity region. For water–bone AAA and AXB deviated by 6 and 1%, respectively. For lung–bone an underestimation in lung (AAA: 5%, AXB: 2%) and overestimation in bone was observed (AAA: 13%, AXB: 4%). For bone–lung phantom overestimation in bone (AAA: 7%, AXB: 1%), a lung underdosage (AAA: 8%, AXB: 5%) was found. Post bone up to 12% difference in the AAA and MC results was observed as opposed to 6% in case of AXB.ConclusionThis study demonstrated the limitation of the AAA (in certain scenarios) and accuracy of AXB for dose estimation inside and around lung and bone inhomogeneities. The dose perturbation effects were found to be slightly dependent on the field size with no obvious EDW dependence.
Collapse
|
14
|
Monte Carlo dose verification of VMAT treatment plans using Elekta Agility 160-leaf MLC. Phys Med 2018; 51:22-31. [DOI: 10.1016/j.ejmp.2018.06.003] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/23/2018] [Revised: 05/26/2018] [Accepted: 06/02/2018] [Indexed: 11/17/2022] Open
|
15
|
Guebert A, Conroy L, Weppler S, Alghamdi M, Conway J, Harper L, Phan T, Olivotto IA, Smith WL, Quirk S. Clinical implementation of AXB from AAA for breast: Plan quality and subvolume analysis. J Appl Clin Med Phys 2018; 19:243-250. [PMID: 29696752 PMCID: PMC5978944 DOI: 10.1002/acm2.12329] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2017] [Revised: 12/06/2017] [Accepted: 03/02/2018] [Indexed: 12/01/2022] Open
Abstract
Purpose Two dose calculation algorithms are available in Varian Eclipse software: Anisotropic Analytical Algorithm (AAA) and Acuros External Beam (AXB). Many Varian Eclipse‐based centers have access to AXB; however, a thorough understanding of how it will affect plan characteristics and, subsequently, clinical practice is necessary prior to implementation. We characterized the difference in breast plan quality between AXB and AAA for dissemination to clinicians during implementation. Methods Locoregional irradiation plans were created with AAA for 30 breast cancer patients with a prescription dose of 50 Gy to the breast and 45 Gy to the regional node, in 25 fractions. The internal mammary chain (IMCCTV) nodes were covered by 80% of the breast dose. AXB, both dose‐to‐water and dose‐to‐medium reporting, was used to recalculate plans while maintaining constant monitor units. Target coverage and organ‐at‐risk doses were compared between the two algorithms using dose–volume parameters. An analysis to assess location‐specific changes was performed by dividing the breast into nine subvolumes in the superior–inferior and left–right directions. Results There were minimal differences found between the AXB and AAA calculated plans. The median difference between AXB and AAA for breastCTVV95%, was <2.5%. For IMCCTV, the median differences V95%, and V80% were <5% and 0%, respectively; indicating IMCCTV coverage only decreased when marginally covered. Mean superficial dose increased by a median of 3.2 Gy. In the subvolume analysis, the medial subvolumes were “hotter” when recalculated with AXB and the lateral subvolumes “cooler” with AXB; however, all differences were within 2 Gy. Conclusion We observed minimal difference in magnitude and spatial distribution of dose when comparing the two algorithms. The largest observable differences occurred in superficial dose regions. Therefore, clinical implementation of AXB from AAA for breast radiotherapy is not expected to result in changes in clinical practice for prescribing or planning breast radiotherapy.
Collapse
Affiliation(s)
- Alexandra Guebert
- Department of Physics and Astronomy, University of Calgary, Calgary, AB, Canada
| | - Leigh Conroy
- Department of Physics and Astronomy, University of Calgary, Calgary, AB, Canada.,Division of Medical Physics, Tom Baker Cancer Centre, Calgary, AB, Canada
| | - Sarah Weppler
- Department of Physics and Astronomy, University of Calgary, Calgary, AB, Canada.,Division of Medical Physics, Tom Baker Cancer Centre, Calgary, AB, Canada
| | - Majed Alghamdi
- Division of Radiation Oncology, Department of Oncology, University of Calgary, Calgary, AB, Canada.,Department of Oncology, Tom Baker Cancer Centre, Calgary, AB, Canada
| | - Jessica Conway
- Division of Radiation Oncology, Department of Oncology, University of Calgary, Calgary, AB, Canada.,Department of Oncology, Tom Baker Cancer Centre, Calgary, AB, Canada
| | - Lindsay Harper
- Department of Oncology, Tom Baker Cancer Centre, Calgary, AB, Canada
| | - Tien Phan
- Division of Radiation Oncology, Department of Oncology, University of Calgary, Calgary, AB, Canada.,Department of Oncology, Tom Baker Cancer Centre, Calgary, AB, Canada
| | - Ivo A Olivotto
- Division of Radiation Oncology, Department of Oncology, University of Calgary, Calgary, AB, Canada.,Department of Oncology, Tom Baker Cancer Centre, Calgary, AB, Canada
| | - Wendy L Smith
- Department of Physics and Astronomy, University of Calgary, Calgary, AB, Canada.,Division of Medical Physics, Tom Baker Cancer Centre, Calgary, AB, Canada.,Division of Radiation Oncology, Department of Oncology, University of Calgary, Calgary, AB, Canada
| | - Sarah Quirk
- Department of Physics and Astronomy, University of Calgary, Calgary, AB, Canada.,Division of Medical Physics, Tom Baker Cancer Centre, Calgary, AB, Canada.,Division of Radiation Oncology, Department of Oncology, University of Calgary, Calgary, AB, Canada
| |
Collapse
|
16
|
Park JM, Park SY, Kim JI, Kang HC, Choi CH. A comparison of treatment plan quality between Tri-Co-60 intensity modulated radiation therapy and volumetric modulated arc therapy for cervical cancer. Phys Med 2017; 40:11-16. [PMID: 28760506 DOI: 10.1016/j.ejmp.2017.06.018] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/17/2017] [Revised: 06/12/2017] [Accepted: 06/15/2017] [Indexed: 12/25/2022] Open
Abstract
PURPOSE To investigate the plan quality of tri-Co-60 intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) for cervical cancer. METHODS A total of 20 patients who received postoperative radiotherapy for cervical cancer were selected. For each patient, a tri-Co-60 IMRT plan for which the target volume was the planning target volume (PTV) generated by adding 1mm isotropic margins from the clinical target volume (CTV) and a VMAT plan for which the target volume was the PTV generated by adding 7mm and 10mm margins from the CTV were generated. The tri-Co-60 IMRT plans were generated with the ViewRay™ system while the VMAT plans were generated with 15-MV photon beams from a linear accelerator (prescription dose=50.4Gy in 28 fractions). RESULTS The average volumes of the PTVs and CTVs were 704.9cc±87.8cc and 271.6cc±51.6cc, respectively. No noticeable differences in the dose-volumetric parameters for the target volumes were observed between the tri-Co-60 IMRT and VMAT plans. The values of V40Gy for the small bowel and rectal wall, V45Gy of the bladder, and V35Gy of the femoral heads for the VMAT plans were 14.6%±7.8%, 54.4%±4.2%, 30.0%±4.7%, and 8.9%±3.3%, respectively. Those of the tri-Co-60 IMRT plans were 2.8%±2.1%, 23.0%±8.9%, 17.1%±6.1%, and 0.3%±0.4%, respectively. CONCLUSIONS Owing to the target margin reduction capability, the tri-Co-60 IMRT plans were more favorable than the VMAT plans for cervical cancer.
Collapse
Affiliation(s)
- Jong Min Park
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea; Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea; Biomedical Research Institute, Seoul National University Hospital, Seoul, Republic of Korea; Center for Convergence Research on Robotics, Advanced Institutes of Convergence Technology, Suwon, Republic of Korea
| | - So-Yeon Park
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea; Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea; Biomedical Research Institute, Seoul National University Hospital, Seoul, Republic of Korea
| | - Jung-In Kim
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea; Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea; Biomedical Research Institute, Seoul National University Hospital, Seoul, Republic of Korea
| | - Hyun-Cheol Kang
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea; Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea; Biomedical Research Institute, Seoul National University Hospital, Seoul, Republic of Korea
| | - Chang Heon Choi
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea; Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea; Biomedical Research Institute, Seoul National University Hospital, Seoul, Republic of Korea.
| |
Collapse
|
17
|
Tian Z, Li Y, Hassan-Rezaeian N, Jiang SB, Jia X. Moving GPU-OpenCL-based Monte Carlo dose calculation toward clinical use: Automatic beam commissioning and source sampling for treatment plan dose calculation. J Appl Clin Med Phys 2017; 18:69-84. [PMID: 28300376 PMCID: PMC5689963 DOI: 10.1002/acm2.12049] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2016] [Revised: 11/17/2016] [Accepted: 12/20/2016] [Indexed: 11/24/2022] Open
Abstract
We have previously developed a GPU‐based Monte Carlo (MC) dose engine on the OpenCL platform, named goMC, with a built‐in analytical linear accelerator (linac) beam model. In this paper, we report our recent improvement on goMC to move it toward clinical use. First, we have adapted a previously developed automatic beam commissioning approach to our beam model. The commissioning was conducted through an optimization process, minimizing the discrepancies between calculated dose and measurement. We successfully commissioned six beam models built for Varian TrueBeam linac photon beams, including four beams of different energies (6 MV, 10 MV, 15 MV, and 18 MV) and two flattening‐filter‐free (FFF) beams of 6 MV and 10 MV. Second, to facilitate the use of goMC for treatment plan dose calculations, we have developed an efficient source particle sampling strategy. It uses the pre‐generated fluence maps (FMs) to bias the sampling of the control point for source particles already sampled from our beam model. It could effectively reduce the number of source particles required to reach a statistical uncertainty level in the calculated dose, as compared to the conventional FM weighting method. For a head‐and‐neck patient treated with volumetric modulated arc therapy (VMAT), a reduction factor of ~2.8 was achieved, accelerating dose calculation from 150.9 s to 51.5 s. The overall accuracy of goMC was investigated on a VMAT prostate patient case treated with 10 MV FFF beam. 3D gamma index test was conducted to evaluate the discrepancy between our calculated dose and the dose calculated in Varian Eclipse treatment planning system. The passing rate was 99.82% for 2%/2 mm criterion and 95.71% for 1%/1 mm criterion. Our studies have demonstrated the effectiveness and feasibility of our auto‐commissioning approach and new source sampling strategy for fast and accurate MC dose calculations for treatment plans.
Collapse
Affiliation(s)
- Zhen Tian
- Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX, 75390, USA
| | - Yongbao Li
- Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX, 75390, USA.,School of Astronautics, Beihang University, Beijing, 100191, China
| | - Nima Hassan-Rezaeian
- Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX, 75390, USA
| | - Steve B Jiang
- Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX, 75390, USA
| | - Xun Jia
- Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX, 75390, USA
| |
Collapse
|
18
|
Yuan J, Zheng Y, Wessels B, Lo SS, Ellis R, Machtay M, Yao M. Experimental Validation of Monte Carlo Simulations Based on a Virtual Source Model for TomoTherapy in a RANDO Phantom. Technol Cancer Res Treat 2016; 15:796-804. [DOI: 10.1177/1533034615605007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2015] [Revised: 07/29/2015] [Accepted: 08/17/2015] [Indexed: 11/17/2022] Open
Abstract
A virtual source model for Monte Carlo simulations of helical TomoTherapy has been developed previously by the authors. The purpose of this work is to perform experiments in an anthropomorphic (RANDO) phantom with the same order of complexity as in clinical treatments to validate the virtual source model to be used for quality assurance secondary check on TomoTherapy patient planning dose. Helical TomoTherapy involves complex delivery pattern with irregular beam apertures and couch movement during irradiation. Monte Carlo simulation, as the most accurate dose algorithm, is desirable in radiation dosimetry. Current Monte Carlo simulations for helical TomoTherapy adopt the full Monte Carlo model, which includes detailed modeling of individual machine component, and thus, large phase space files are required at different scoring planes. As an alternative approach, we developed a virtual source model without using the large phase space files for the patient dose calculations previously. In this work, we apply the simulation system to recompute the patient doses, which were generated by the treatment planning system in an anthropomorphic phantom to mimic the real patient treatments. We performed thermoluminescence dosimeter point dose and film measurements to compare with Monte Carlo results. Thermoluminescence dosimeter measurements show that the relative difference in both Monte Carlo and treatment planning system is within 3%, with the largest difference less than 5% for both the test plans. The film measurements demonstrated 85.7% and 98.4% passing rate using the 3 mm/3% acceptance criterion for the head and neck and lung cases, respectively. Over 95% passing rate is achieved if 4 mm/4% criterion is applied. For the dose–volume histograms, very good agreement is obtained between the Monte Carlo and treatment planning system method for both cases. The experimental results demonstrate that the virtual source model Monte Carlo system can be a viable option for the accurate dose calculation of helical TomoTherapy.
Collapse
Affiliation(s)
- Jiankui Yuan
- University Hospitals, Case Medical Center, Cleveland, OH, USA
| | - Yiran Zheng
- University Hospitals, Case Medical Center, Cleveland, OH, USA
| | - Barry Wessels
- University Hospitals, Case Medical Center, Cleveland, OH, USA
| | - Simon S. Lo
- University Hospitals, Case Medical Center, Cleveland, OH, USA
| | - Rodney Ellis
- University Hospitals, Case Medical Center, Cleveland, OH, USA
| | | | - Min Yao
- University Hospitals, Case Medical Center, Cleveland, OH, USA
| |
Collapse
|
19
|
Reynaert N, Demol B, Charoy M, Bouchoucha S, Crop F, Wagner A, Lacornerie T, Dubus F, Rault E, Comte P, Cayez R, Boydev C, Pasquier D, Mirabel X, Lartigau E, Sarrazin T. Clinical implementation of a Monte Carlo based treatment plan QA platform for validation of Cyberknife and Tomotherapy treatments. Phys Med 2016; 32:1225-1237. [DOI: 10.1016/j.ejmp.2016.09.009] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/10/2016] [Revised: 09/12/2016] [Accepted: 09/13/2016] [Indexed: 10/21/2022] Open
|
20
|
Attar MA, Bahadur YA, Constantinescu CT, Eltaher MM. Lung dose analysis in loco-regional hypofractionated radiotherapy of breast cancer. Saudi Med J 2016; 37:631-7. [PMID: 27279508 PMCID: PMC4931643 DOI: 10.15537/smj.2016.6.14008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
OBJECTIVES To report the ipsilateral lung dosimetry data of breast cancer (BC) patients treated with loco-regional hypofractionated radiotherapy (HFRT). METHODS Treatment plans of 150 patients treated in the Radiotherapy Unit, King Abdulaziz University Hospital, Jeddah, Kingdom of Saudi Arabia between January 2012 and March 2015 by HFRT for BC were retrospectively reviewed. All patients received 42.4 Gy in 16 fractions by tangential and supra-clavicular fields with 6 MV, 18 MV, or mixed energies. Ipsilateral lung dosimetric data V20Gy and mean lung dose (MLD) were recorded. Correlations between lung dose, patient characteristics, and treatment delivery parameters were assessed by a logistic regression test. RESULTS The mean ipsilateral lung V20Gy was 24.6% and mean MLD was 11.9 Gy. A weak, but statistically significant correlation was found between lung dose and lung volume (p=0.043). The lung dose was significantly decreasing with patient separation and depth of axillary lymph node (ALN) and supra-claviculary lymph nodes (SCLN) (p less than 0.0001), and increasing with ALN (p=0.001) and SCLN (p=0.003) dose coverage. Lung dose significantly decreased with beam energy (p less than 0.0001): mean V20Gy was 27.8%, 25.4% for 6 MV, mixed energy, and 21.2% for 18 MV. The use of a low breast-board angle correlates with low lung dose. CONCLUSION Our data suggest that the use of high energy photon beams and low breast-board angulation can reduce the lung dose.
Collapse
Affiliation(s)
- Mohammad A Attar
- Department of Radiology, King Abdulaziz University Hospital, Jeddah, Kingdom of Saudi Arabia. E-mail.
| | | | | | | |
Collapse
|
21
|
Accuracy of dose calculation algorithms for virtual heterogeneous phantoms and intensity-modulated radiation therapy in the head and neck. Radiol Phys Technol 2015; 9:77-87. [DOI: 10.1007/s12194-015-0336-z] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2015] [Revised: 10/05/2015] [Accepted: 10/05/2015] [Indexed: 11/29/2022]
|
22
|
Sini C, Broggi S, Fiorino C, Cattaneo GM, Calandrino R. Accuracy of dose calculation algorithms for static and rotational IMRT of lung cancer: A phantom study. Phys Med 2015; 31:382-90. [DOI: 10.1016/j.ejmp.2015.02.013] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/10/2014] [Revised: 02/17/2015] [Accepted: 02/20/2015] [Indexed: 10/23/2022] Open
|
23
|
Dosimetric study of the AAA algorithm for the VMAT technique using an anthropomorphic phantom in the pelvic region. JOURNAL OF RADIOTHERAPY IN PRACTICE 2015. [DOI: 10.1017/s1460396914000508] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AbstractPurposeThe objective of this work was to investigate the accuracy of AAA dose calculation algorithm for RapidArc volumetric modulated technique (VMAT) in the presence of anatomical heterogeneities in the pelvic region.Material and methodsAn anthropomorphic phantom was used to simulate a prostate case, delineating planning target volumes (PTVs) and organs at risk. VMAT plans were optimised in eclipse (v10·0) treatment planning system (TPS). The dose distributions were calculated by the AAA dose calculation algorithm. A total of 49 thermoluminiscent dosimeters were inserted into the anthropomorphic phantom and dose measurements were compared with the predicted TPS doses.ResultsThe average dose variation was −1·5% for planning target volume corresponding to the prostate and −0·3% for planning target volume corresponding to the pelvic nodes, −0·2% for the rectum, +2·4% for the bladder, −2·0% for the femoral heads and +1·0% for the intestinal package.ConclusionAAA is a reliable dose calculation for the treatment with VMAT in the anatomy of the pelvis.
Collapse
|
24
|
Su L, Yang Y, Bednarz B, Sterpin E, Du X, Liu T, Ji W, Xu XG. ARCHERRT - a GPU-based and photon-electron coupled Monte Carlo dose computing engine for radiation therapy: software development and application to helical tomotherapy. Med Phys 2015; 41:071709. [PMID: 24989378 DOI: 10.1118/1.4884229] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023] Open
Abstract
PURPOSE Using the graphical processing units (GPU) hardware technology, an extremely fast Monte Carlo (MC) code ARCHERRT is developed for radiation dose calculations in radiation therapy. This paper describes the detailed software development and testing for three clinical TomoTherapy® cases: the prostate, lung, and head & neck. METHODS To obtain clinically relevant dose distributions, phase space files (PSFs) created from optimized radiation therapy treatment plan fluence maps were used as the input to ARCHERRT. Patient-specific phantoms were constructed from patient CT images. Batch simulations were employed to facilitate the time-consuming task of loading large PSFs, and to improve the estimation of statistical uncertainty. Furthermore, two different Woodcock tracking algorithms were implemented and their relative performance was compared. The dose curves of an Elekta accelerator PSF incident on a homogeneous water phantom were benchmarked against DOSXYZnrc. For each of the treatment cases, dose volume histograms and isodose maps were produced from ARCHERRT and the general-purpose code, GEANT4. The gamma index analysis was performed to evaluate the similarity of voxel doses obtained from these two codes. The hardware accelerators used in this study are one NVIDIA K20 GPU, one NVIDIA K40 GPU, and six NVIDIA M2090 GPUs. In addition, to make a fairer comparison of the CPU and GPU performance, a multithreaded CPU code was developed using OpenMP and tested on an Intel E5-2620 CPU. RESULTS For the water phantom, the depth dose curve and dose profiles from ARCHERRT agree well with DOSXYZnrc. For clinical cases, results from ARCHERRT are compared with those from GEANT4 and good agreement is observed. Gamma index test is performed for voxels whose dose is greater than 10% of maximum dose. For 2%/2mm criteria, the passing rates for the prostate, lung case, and head & neck cases are 99.7%, 98.5%, and 97.2%, respectively. Due to specific architecture of GPU, modified Woodcock tracking algorithm performed inferior to the original one. ARCHERRT achieves a fast speed for PSF-based dose calculations. With a single M2090 card, the simulations cost about 60, 50, 80 s for three cases, respectively, with the 1% statistical error in the PTV. Using the latest K40 card, the simulations are 1.7-1.8 times faster. More impressively, six M2090 cards could finish the simulations in 8.9-13.4 s. For comparison, the same simulations on Intel E5-2620 (12 hyperthreading) cost about 500-800 s. CONCLUSIONS ARCHERRT was developed successfully to perform fast and accurate MC dose calculation for radiotherapy using PSFs and patient CT phantoms.
Collapse
Affiliation(s)
- Lin Su
- Nuclear Engineering Program, Rensselaer Polytechnic Institute, Troy, New York 12180
| | - Youming Yang
- Medical Physics, University of Wisconsin, Madison, Wisconsin 53706
| | - Bryan Bednarz
- Medical Physics, University of Wisconsin, Madison, Wisconsin 53706
| | - Edmond Sterpin
- Molecular Imaging, Radiotherapy and Oncology, Université catholique de Louvain, Brussels, Belgium 1348
| | - Xining Du
- Nuclear Engineering Program, Rensselaer Polytechnic Institute, Troy, New York 12180
| | - Tianyu Liu
- Nuclear Engineering Program, Rensselaer Polytechnic Institute, Troy, New York 12180
| | - Wei Ji
- Nuclear Engineering Program, Rensselaer Polytechnic Institute, Troy, New York 12180
| | - X George Xu
- Nuclear Engineering Program, Rensselaer Polytechnic Institute, Troy, New York 12180
| |
Collapse
|
25
|
Li Y, Rodrigues A, Li T, Yuan L, Yin FF, Wu QJ. Impact of dose calculation accuracy during optimization on lung IMRT plan quality. J Appl Clin Med Phys 2015; 16:5137. [PMID: 25679172 PMCID: PMC5689966 DOI: 10.1120/jacmp.v16i1.5137] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2014] [Revised: 10/21/2014] [Accepted: 10/14/2014] [Indexed: 12/25/2022] Open
Abstract
The purpose of this study was to evaluate the effect of dose calculation accuracy and the use of an intermediate dose calculation step during the optimization of intensity‐modulated radiation therapy (IMRT) planning on the final plan quality for lung cancer patients. This study included replanning for 11 randomly selected free‐breathing lung IMRT plans. The original plans were optimized using a fast pencil beam convolution algorithm. After optimization, the final dose calculation was performed using the analytical anisotropic algorithm (AAA). The Varian Treatment Planning System (TPS) Eclipse v11, includes an option to perform intermediate dose calculation during optimization using the AAA. The new plans were created using this intermediate dose calculation during optimization with the same planning objectives and dose constraints as in the original plan. Differences in dosimetric parameters for the planning target volume (PTV) dose coverage, organs‐at‐risk (OARs) dose sparing, and the number of monitor units (MU) between the original and new plans were analyzed. Statistical significance was determined with a p‐value of less than 0.05. All plans were normalized to cover 95% of the PTV with the prescription dose. Compared with the original plans, the PTV in the new plans had on average a lower maximum dose (69.45 vs. 71.96 Gy, p=0.005), a better homogeneity index (HI) (0.08 vs. 0.12, p=0.002), and a better conformity index (CI) (0.69 vs. 0.59, p=0.003). In the new plans, lung sparing was increased as the volumes receiving 5, 10, and 30 Gy were reduced when compared to the original plans (40.39% vs. 42.73%, p=0.005; 28.93% vs. 30.40%, p=0.001; 14.11% vs. 14.84%, p=0.031). The volume receiving 20 Gy was not significantly lower (19.60% vs. 20.38%, p=0.052). Further, the mean dose to the lung was reduced in the new plans (11.55 vs. 12.12 Gy, p=0.024). For the esophagus, the mean dose, the maximum dose, and the volumes receiving 20 and 60 Gy were lower in the new plans than in the original plans (17.91 vs. 19.24 Gy, p=0.004; 57.32 vs. 59.81 Gy, p=0.020; 39.34% vs. 41.59%, p=0.097; 12.56% vs. 15.35%, p=0.101). For the heart, the mean dose, the maximum dose, and the volume receiving 40 Gy were also lower in new plans (11.07 vs. 12.04 Gy, p=0.007; 56.41 vs. 57.7 Gy, p=0.027; 7.16% vs. 9.37%, p=0.012). The maximum dose to the spinal cord in the new plans was significantly lower than in the original IMRT plans (29.1 vs. 31.39 Gy, p=0.014). Difference in MU between the IMRT plans was not significant (1216.90 vs. 1198.91, p=0.328). In comparison to the original plans, the number of iterations needed to meet the optimization objectives in the new plans was reduced by a factor of 2 (2–3 vs. 5–6 iterations). Further, optimization was 30% faster corresponding to an average time savings of 10–15 min for the reoptimized plans. Accuracy of the dose calculation algorithm during optimization has an impact on planning efficiency, as well as on the final plan dosimetric quality. For lung IMRT treatment planning, utilizing the intermediate dose calculation during optimization is feasible for dose homogeneity improvement of the PTV and for improvement of optimization efficiency. PACS numbers: 87.55.D‐, 87.55.de, 87.55.dk
Collapse
Affiliation(s)
- Ying Li
- Department of Oncology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, 400016, China.
| | | | | | | | | | | |
Collapse
|
26
|
Yuan J, Rong Y, Chen Q. A virtual source model for Monte Carlo simulation of helical tomotherapy. J Appl Clin Med Phys 2015; 16:4992. [PMID: 25679157 PMCID: PMC5689983 DOI: 10.1120/jacmp.v16i1.4992] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2014] [Revised: 08/29/2014] [Accepted: 08/25/2014] [Indexed: 11/23/2022] Open
Abstract
The purpose of this study was to present a Monte Carlo (MC) simulation method based on a virtual source, jaw, and MLC model to calculate dose in patient for helical tomotherapy without the need of calculating phase‐space files (PSFs). Current studies on the tomotherapy MC simulation adopt a full MC model, which includes extensive modeling of radiation source, primary and secondary jaws, and multileaf collimator (MLC). In the full MC model, PSFs need to be created at different scoring planes to facilitate the patient dose calculations. In the present work, the virtual source model (VSM) we established was based on the gold standard beam data of a tomotherapy unit, which can be exported from the treatment planning station (TPS). The TPS‐generated sinograms were extracted from the archived patient XML (eXtensible Markup Language) files. The fluence map for the MC sampling was created by incorporating the percentage leaf open time (LOT) with leaf filter, jaw penumbra, and leaf latency contained from sinogram files. The VSM was validated for various geometry setups and clinical situations involving heterogeneous media and delivery quality assurance (DQA) cases. An agreement of <1% was obtained between the measured and simulated results for percent depth doses (PDDs) and open beam profiles for all three jaw settings in the VSM commissioning. The accuracy of the VSM leaf filter model was verified in comparing the measured and simulated results for a Picket Fence pattern. An agreement of <2% was achieved between the presented VSM and a published full MC model for heterogeneous phantoms. For complex clinical head and neck (HN) cases, the VSM‐based MC simulation of DQA plans agreed with the film measurement with 98% of planar dose pixels passing on the 2%/2 mm gamma criteria. For patient treatment plans, results showed comparable dose‐volume histograms (DVHs) for planning target volumes (PTVs) and organs at risk (OARs). Deviations observed in this study were consistent with literature. The VSM‐based MC simulation approach can be feasibly built from the gold standard beam model of a tomotherapy unit. The accuracy of the VSM was validated against measurements in homogeneous media, as well as published full MC model in heterogeneous media. PACS numbers: 87.53.‐j, 87.55.K‐
Collapse
|
27
|
Yeh C, Tung C, Lee C, Lin M, Chao T. Measurement-based Monte Carlo simulation of high definition dose evaluation for nasopharyngeal cancer patients treated by using intensity modulated radiation therapy. RADIAT MEAS 2014. [DOI: 10.1016/j.radmeas.2014.05.011] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|
28
|
Koncek O, Krivonoska J. A 3D superposition pencil beam dose calculation algorithm for a 60Co therapy unit and its verification by MC simulation. Radiat Phys Chem Oxf Engl 1993 2014. [DOI: 10.1016/j.radphyschem.2014.03.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
29
|
Petillion S, Swinnen A, Defraene G, Verhoeven K, Weltens C, Van den Heuvel F. The photon dose calculation algorithm used in breast radiotherapy has significant impact on the parameters of radiobiological models. J Appl Clin Med Phys 2014; 15:259–269. [PMID: 25207416 PMCID: PMC5875495 DOI: 10.1120/jacmp.v15i4.4853] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2013] [Revised: 03/19/2014] [Accepted: 03/12/2014] [Indexed: 11/23/2022] Open
Abstract
The comparison of the pencil beam dose calculation algorithm with modified Batho heterogeneity correction (PBC-MB) and the analytical anisotropic algorithm (AAA) and the mutual comparison of advanced dose calculation algorithms used in breast radiotherapy have focused on the differences between the physical dose distributions. Studies on the radiobiological impact of the algorithm (both on the tumor control and the moderate breast fibrosis prediction) are lacking. We, therefore, investigated the radiobiological impact of the dose calculation algorithm in whole breast radiotherapy. The clinical dose distributions of 30 breast cancer patients, calculated with PBC-MB, were recalculated with fixed monitor units using more advanced algorithms: AAA and Acuros XB. For the latter, both dose reporting modes were used (i.e., dose-to-medium and dose-to-water). Next, the tumor control probability (TCP) and the normal tissue complication probability (NTCP) of each dose distribution were calculated with the Poisson model and with the relative seriality model, respectively. The endpoint for the NTCP calculation was moderate breast fibrosis five years post treatment. The differences were checked for significance with the paired t-test. The more advanced algorithms predicted a significantly lower TCP and NTCP of moderate breast fibrosis then found during the corresponding clinical follow-up study based on PBC calculations. The differences varied between 1% and 2.1% for the TCP and between 2.9% and 5.5% for the NTCP of moderate breast fibrosis. The significant differences were eliminated by determination of algorithm-specific model parameters using least square fitting. Application of the new parameters on a second group of 30 breast cancer patients proved their appropriateness. In this study, we assessed the impact of the dose calculation algorithms used in whole breast radiotherapy on the parameters of the radiobiological models. The radiobiological impact was eliminated by determination of algorithm specific model parameters.
Collapse
|
30
|
Tomiyama Y, Araki F, Oono T, Hioki K. Three-dimensional gamma analysis of dose distributions in individual structures for IMRT dose verification. Radiol Phys Technol 2014; 7:303-9. [PMID: 24796955 DOI: 10.1007/s12194-014-0266-1] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2013] [Revised: 04/02/2014] [Accepted: 04/03/2014] [Indexed: 12/13/2022]
Abstract
Our purpose in this study was to implement three-dimensional (3D) gamma analysis for structures of interest such as the planning target volume (PTV) or clinical target volume (CTV), and organs at risk (OARs) for intensity-modulated radiation therapy (IMRT) dose verification. IMRT dose distributions for prostate and head and neck (HN) cancer patients were calculated with an analytical anisotropic algorithm in an Eclipse (Varian Medical Systems) treatment planning system (TPS) and by Monte Carlo (MC) simulation. The MC dose distributions were calculated with EGSnrc/BEAMnrc and DOSXYZnrc user codes under conditions identical to those for the TPS. The prescribed doses were 76 Gy/38 fractions with five-field IMRT for the prostate and 33 Gy/17 fractions with seven-field IMRT for the HN. TPS dose distributions were verified by the gamma passing rates for the whole calculated volume, PTV or CTV, and OARs by use of 3D gamma analysis with reference to MC dose distributions. The acceptance criteria for the 3D gamma analysis were 3/3 and 2 %/2 mm for a dose difference and a distance to agreement. The gamma passing rates in PTV and OARs for the prostate IMRT plan were close to 100 %. For the HN IMRT plan, the passing rates of 2 %/2 mm in CTV and OARs were substantially lower because inhomogeneous tissues such as bone and air in the HN are included in the calculation area. 3D gamma analysis for individual structures is useful for IMRT dose verification.
Collapse
Affiliation(s)
- Yuuki Tomiyama
- Graduate School of Health Sciences, Kumamoto University, 4-24-1 Kuhonji, Kumamoto, Japan,
| | | | | | | |
Collapse
|
31
|
Disher B, Hajdok G, Gaede S, Mulligan M, Battista JJ. Forcing lateral electron disequilibrium to spare lung tissue: a novel technique for stereotactic body radiation therapy of lung cancer. Phys Med Biol 2013; 58:6641-62. [PMID: 24018569 DOI: 10.1088/0031-9155/58/19/6641] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Stereotactic body radiation therapy (SBRT) has quickly become a preferred treatment option for early-stage lung cancer patients who are ineligible for surgery. This technique uses tightly conformed megavoltage (MV) x-ray beams to irradiate a tumour with ablative doses in only a few treatment fractions. Small high energy x-ray fields can cause lateral electron disequilibrium (LED) to occur within low density media, which can reduce tumour dose. These dose effects may be challenging to predict using analytic dose calculation algorithms, especially at higher beam energies. As a result, previous authors have suggested using low energy photons (<10 MV) and larger fields (>5 × 5 cm(2)) for lung cancer patients to avoid the negative dosimetric effects of LED. In this work, we propose a new form of SBRT, described as LED-optimized SBRT (LED-SBRT), which utilizes radiotherapy (RT) parameters designed to cause LED to advantage. It will be shown that LED-SBRT creates enhanced dose gradients at the tumour/lung interface, which can be used to manipulate tumour dose, and/or normal lung dose. To demonstrate the potential benefits of LED-SBRT, the DOSXYZnrc (National Research Council of Canada, Ottawa, ON) Monte Carlo (MC) software was used to calculate dose within a cylindrical phantom and a typical lung patient. 6 MV or 18 MV x-ray fields were focused onto a small tumour volume (diameter ∼1 cm). For the phantom, square fields of 1 × 1 cm(2), 3 × 3 cm(2), or 5 × 5 cm(2) were applied. However, in the patient, 3 × 1 cm(2), 3 × 2 cm(2), 3 × 2.5 cm(2), or 3 × 3 cm(2) field sizes were used in simulations to assure target coverage in the superior-inferior direction. To mimic a 180° SBRT arc in the (symmetric) phantom, a single beam profile was calculated, rotated, and beams were summed at 1° segments to accumulate an arc dose distribution. For the patient, a 360° arc was modelled with 36 equally weighted (and spaced) fields focused on the tumour centre. A planning target volume (PTV) was generated by considering the extent of tumour motion over the patient's breathing cycle and set-up uncertainties. All patient dose results were normalized such that at least 95% of the PTV received at least 54 Gy (i.e. D95 = 54 Gy). Further, we introduce 'LED maps' as a novel clinical tool to compare the magnitude of LED resulting from the various SBRT arc plans. Results from the phantom simulation suggest that the best lung sparing occurred for RT parameters that cause severe LED. For equal tumour dose coverage, normal lung dose (2 cm outside the target region) was reduced from 92% to 23%, comparing results between the 18 MV (5 × 5 cm(2)) and 18 MV (1 × 1 cm(2)) arc simulations. In addition to reduced lung dose for the 18 MV (1 × 1 cm(2)) arc, maximal tumour dose increased beyond 125%. Thus, LED can create steep dose gradients to spare normal lung, while increasing tumour dose levels (if desired). In the patient simulation, a LED-optimized arc plan was designed using either 18 MV (3 × 1 cm(2)) or 6 MV (3 × 3cm(2)) beams. Both plans met the D95 dose coverage requirement for the target. However, the LED-optimized plan increased the maximum, mean, and minimum dose within the PTV by as much as 80 Gy, 11 Gy, and 3 Gy, respectively. Despite increased tumour dose levels, the 18 MV (3 × 1 cm(2)) arc plan improved or maintained the V20, V5, and mean lung dose metrics compared to the 6 MV (3 × 3 cm(2)) simulation. We conclude that LED-SBRT has the potential to increase dose gradients, and dose levels within a small lung tumour. The magnitude of tumour dose increase or lung sparing can be optimized through manipulation of RT parameters (e.g. beam energy and field size).
Collapse
Affiliation(s)
- Brandon Disher
- Department of Physics and Engineering, London Regional Cancer Program, London Health Sciences Centre, 790 Commissioners Road East, London, Ontario, N6A 4L6, Canada. Department of Medical Biophysics, Western University, Schulich School of Medicine and Dentistry, London, Ontario, N6A 5C1, Canada
| | | | | | | | | |
Collapse
|
32
|
Bufacchi A, Nardiello B, Capparella R, Begnozzi L. Clinical implications in the use of the PBC algorithm versus the AAA by comparison of different NTCP models/parameters. Radiat Oncol 2013; 8:164. [PMID: 23826854 PMCID: PMC3750611 DOI: 10.1186/1748-717x-8-164] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2012] [Accepted: 06/13/2013] [Indexed: 12/25/2022] Open
Abstract
Purpose Retrospective analysis of 3D clinical treatment plans to investigate qualitative, possible, clinical consequences of the use of PBC versus AAA. Methods The 3D dose distributions of 80 treatment plans at four different tumour sites, produced using PBC algorithm, were recalculated using AAA and the same number of monitor units provided by PBC and clinically delivered to each patient; the consequences of the difference on the dose-effect relations for normal tissue injury were studied by comparing different NTCP model/parameters extracted from a review of published studies. In this study the AAA dose calculation is considered as benchmark data. The paired Student t-test was used for statistical comparison of all results obtained from the use of the two algorithms. Results In the prostate plans, the AAA predicted lower NTCP value (NTCPAAA) for the risk of late rectal bleeding for each of the seven combinations of NTCP parameters, the maximum mean decrease was 2.2%. In the head-and-neck treatments, each combination of parameters used for the risk of xerostemia from irradiation of the parotid glands involved lower NTCPAAA, that varied from 12.8% (sd=3.0%) to 57.5% (sd=4.0%), while when the PBC algorithm was used the NTCPPBC’s ranging was from 15.2% (sd=2.7%) to 63.8% (sd=3.8%), according the combination of parameters used; the differences were statistically significant. Also NTCPAAA regarding the risk of radiation pneumonitis in the lung treatments was found to be lower than NTCPPBC for each of the eight sets of NTCP parameters; the maximum mean decrease was 4.5%. A mean increase of 4.3% was found when the NTCPAAA was calculated by the parameters evaluated from dose distribution calculated by a convolution-superposition (CS) algorithm. A markedly different pattern was observed for the risk relating to the development of pneumonitis following breast treatments: the AAA predicted higher NTCP value. The mean NTCPAAA varied from 0.2% (sd = 0.1%) to 2.1% (sd = 0.3%), while the mean NTCPPBC varied from 0.1% (sd = 0.0%) to 1.8% (sd = 0.2%) depending on the chosen parameters set. Conclusions When the original PBC treatment plans were recalculated using AAA with the same number of monitor units provided by PBC, the NTCPAAA was lower than the NTCPPBC, except for the breast treatments. The NTCP is strongly affected by the wide-ranging values of radiobiological parameters.
Collapse
Affiliation(s)
- Antonella Bufacchi
- Medical Physics, PioXI Clinic and UOC Medical Physics, S Giovanni Calibita Fatebenefratelli Hospital, Rome, Italy.
| | | | | | | |
Collapse
|
33
|
Wu VW, Tse TK, Ho CL, Yeung EC. A comparison between anisotropic analytical and multigrid superposition dose calculation algorithms in radiotherapy treatment planning. Med Dosim 2013; 38:209-14. [DOI: 10.1016/j.meddos.2013.02.001] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2011] [Revised: 02/08/2013] [Accepted: 02/19/2013] [Indexed: 10/27/2022]
|
34
|
Han T, Followill D, Mikell J, Repchak R, Molineu A, Howell R, Salehpour M, Mourtada F. Dosimetric impact of Acuros XB deterministic radiation transport algorithm for heterogeneous dose calculation in lung cancer. Med Phys 2013; 40:051710. [PMID: 23635258 PMCID: PMC3651262 DOI: 10.1118/1.4802216] [Citation(s) in RCA: 55] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2013] [Revised: 03/21/2013] [Accepted: 04/05/2013] [Indexed: 11/07/2022] Open
Abstract
PURPOSE The novel deterministic radiation transport algorithm, Acuros XB (AXB), has shown great potential for accurate heterogeneous dose calculation. However, the clinical impact between AXB and other currently used algorithms still needs to be elucidated for translation between these algorithms. The purpose of this study was to investigate the impact of AXB for heterogeneous dose calculation in lung cancer for intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT). METHODS The thorax phantom from the Radiological Physics Center (RPC) was used for this study. IMRT and VMAT plans were created for the phantom in the Eclipse 11.0 treatment planning system. Each plan was delivered to the phantom three times using a Varian Clinac iX linear accelerator to ensure reproducibility. Thermoluminescent dosimeters (TLDs) and Gafchromic EBT2 film were placed inside the phantom to measure delivered doses. The measurements were compared with dose calculations from AXB 11.0.21 and the anisotropic analytical algorithm (AAA) 11.0.21. Two dose reporting modes of AXB, dose-to-medium in medium (Dm,m) and dose-to-water in medium (Dw,m), were studied. Point doses, dose profiles, and gamma analysis were used to quantify the agreement between measurements and calculations from both AXB and AAA. The computation times for AAA and AXB were also evaluated. RESULTS For the RPC lung phantom, AAA and AXB dose predictions were found in good agreement to TLD and film measurements for both IMRT and VMAT plans. TLD dose predictions were within 0.4%-4.4% to AXB doses (both Dm,m and Dw,m); and within 2.5%-6.4% to AAA doses, respectively. For the film comparisons, the gamma indexes (± 3%∕3 mm criteria) were 94%, 97%, and 98% for AAA, AXB_Dm,m, and AXB_Dw,m, respectively. The differences between AXB and AAA in dose-volume histogram mean doses were within 2% in the planning target volume, lung, heart, and within 5% in the spinal cord. However, differences up to 8% between AXB and AAA were found at lung∕soft tissue interface regions for individual IMRT fields. AAA was found to be 5-6 times faster than AXB for IMRT, while AXB was 4-5 times faster than AAA for VMAT plan. CONCLUSIONS AXB is satisfactorily accurate for the dose calculation in lung cancer for both IMRT and VMAT plans. The differences between AXB and AAA are generally small except in heterogeneous interface regions. AXB Dw,m and Dm,m calculations are similar inside the soft tissue and lung regions. AXB can benefit lung VMAT plans by both improving accuracy and reducing computation time.
Collapse
Affiliation(s)
- Tao Han
- Department of Radiation Physics, the University of Texas MD Anderson Cancer Center, Houston, Texas 77030, USA
| | | | | | | | | | | | | | | |
Collapse
|
35
|
Mampuya WA, Matsuo Y, Nakamura A, Nakamura M, Mukumoto N, Miyabe Y, Narabayashi M, Sakanaka K, Mizowaki T, Hiraoka M. Differences in dose-volumetric data between the analytical anisotropic algorithm and the x-ray voxel Monte Carlo algorithm in stereotactic body radiation therapy for lung cancer. Med Dosim 2013; 38:95-9. [DOI: 10.1016/j.meddos.2012.07.007] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2012] [Revised: 07/01/2012] [Accepted: 07/30/2012] [Indexed: 11/25/2022]
|
36
|
Lin MH, Li J, Price RA, Wang L, Lee CC, Ma CM. The dosimetric impact of dental implants on head-and-neck volumetric modulated arc therapy. Phys Med Biol 2013; 58:1027-40. [DOI: 10.1088/0031-9155/58/4/1027] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
37
|
Chow JCL, Jiang R, Owrangi AM. Dosimetry of small bone joint calculated by the analytical anisotropic algorithm: a Monte Carlo evaluation using the EGSnrc. J Appl Clin Med Phys 2013; 15:4588. [PMID: 24423828 PMCID: PMC5711239 DOI: 10.1120/jacmp.v15i1.4588] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2013] [Revised: 08/18/2013] [Accepted: 08/16/2013] [Indexed: 11/23/2022] Open
Abstract
This study compared a small bone joint dosimetry calculated by the anisotropic analytical algorithm (AAA) and Monte Carlo simulation using megavoltage (MV) photon beams. The performance of the AAA in the joint dose calculation was evaluated using Monte Carlo simulation, and dependences of joint dose on its width and beam angle were investigated. Small bone joint phantoms containing a vertical water layer (0.5‐2 mm) sandwiched by two bones (2×2×2cm3) were irradiated by the 6 and 15 MV photon beams with field size equal to 4×4 cm2. Depth doses along the central beam axis in a joint (cartilage) were calculated with and without a bolus (thickness=1.5cm) added on top of the phantoms. Different beam angles (0°‐15°) were used with the isocenter set to the center of the bone joint for dose calculations using the AAA (Eclipse treatment planning system) and Monte Carlo simulation (the EGSnrc code). For dosimetry comparison and normalization, dose calculations were repeated in homogeneous water phantoms with the bone substituted by water. Comparing the calculated dosimetry between the AAA and Monte Carlo simulation, the AAA underestimated joint doses varying with its widths by about 6%‐12% for 6 MV and 12%‐23% for 15 MV without bolus, and by 7% for 6 MV and 13%‐17% for 15 MV with bolus. Moreover, joint doses calculated by the AAA did not vary with the joint width and beam angle. From Monte Carlo results, there was a decrease in the calculated joint dose as the joint width increased, and a slight decrease as the beam angle increased. When bolus was added to the phantom, it was found that variations of joint dose with its width and beam angle became less significant for the 6 MV photon beams. In conclusion, dosimetry deviation in small bone joint calculated by the AAA and Monte Carlo simulation was studied using the 6 and 15 MV photon beam. The AAA could not predict variations of joint dose with its width and beam angle, which were predicted by the Monte Carlo simulations. PACS numbers: 87.55.K‐; 87.53.Bn; 87.53.‐j
Collapse
|
38
|
Herman TDLF, Hibbitts K, Herman T, Ahmad S. Evaluation of pencil beam convolution and anisotropic analytical algorithms in stereotactic lung irradiation. J Med Phys 2012; 36:234-8. [PMID: 22228933 PMCID: PMC3249735 DOI: 10.4103/0971-6203.89974] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2011] [Revised: 06/09/2011] [Accepted: 07/12/2011] [Indexed: 12/31/2022] Open
Abstract
The aim of this study was to evaluate differences in dose distributions in stereotactic body radiation therapy treatment plans for lung tumors calculated with pencil beam convolution (PBC) algorithm with modified Batho power law (MBPL) versus heterogeneity corrected anisotropic analytical algorithm (AAA) of the Varian Eclipse treatment planning system. The four-dimensional computed tomography images from 20 patients with lung cancer were used to create treatment plans. Plans used five to seven nonopposing coplanar 6 MV beams. Plans generated with the PBC algorithm and MBPL for tissue heterogeneity corrections were optimized to deliver 60 Gy in three fractions to at least 95% of the planned target volume, and the normal tissue doses for spinal cord, esophagus, heart, and ipsilateral bronchus were restricted to less than 18, 27, 30, and 30 Gy, respectively. Plans were recalculated with AAA, retaining identical beam arrangements, photon beam fluences, and monitor units. The pencil beam plans, designed to deliver 60 Gy, delivered on average 51.6 Gy when re-calculated with the AAA, suggesting a reduction of at least 10% to prescription dose is appropriate when calculating with the AAA.
Collapse
Affiliation(s)
- Tania De La Fuente Herman
- Department of Radiation Oncology, University of Oklahoma Health Sciences Center, Oklahoma City, OK, USA
| | | | | | | |
Collapse
|
39
|
Oldham M, Thomas A, O'Daniel J, Juang T, Ibbott G, Adamovics J, Kirkpatrick JP. A quality assurance method that utilizes 3D dosimetry and facilitates clinical interpretation. Int J Radiat Oncol Biol Phys 2012; 84:540-6. [PMID: 22361085 PMCID: PMC3832997 DOI: 10.1016/j.ijrobp.2011.12.015] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2011] [Revised: 11/18/2011] [Accepted: 11/29/2011] [Indexed: 01/27/2023]
Abstract
PURPOSE To demonstrate a new three-dimensional (3D) quality assurance (QA) method that provides comprehensive dosimetry verification and facilitates evaluation of the clinical significance of QA data acquired in a phantom. Also to apply the method to investigate the dosimetric efficacy of base-of-skull (BOS) intensity-modulated radiotherapy (IMRT) treatment. METHODS AND MATERIALS Two types of IMRT QA verification plans were created for 6 patients who received BOS IMRT. The first plan enabled conventional 2D planar IMRT QA using the Varian portal dosimetry system. The second plan enabled 3D verification using an anthropomorphic head phantom. In the latter, the 3D dose distribution was measured using the DLOS/Presage dosimetry system (DLOS = Duke Large-field-of-view Optical-CT System, Presage Heuris Pharma, Skillman, NJ), which yielded isotropic 2-mm data throughout the treated volume. In a novel step, measured 3D dose distributions were transformed back to the patient's CT to enable calculation of dose-volume histograms (DVH) and dose overlays. Measured and planned patient DVHs were compared to investigate clinical significance. RESULTS Close agreement between measured and calculated dose distributions was observed for all 6 cases. For gamma criteria of 3%, 2 mm, the mean passing rate for portal dosimetry was 96.8% (range, 92.0%-98.9%), compared to 94.9% (range, 90.1%-98.9%) for 3D. There was no clear correlation between 2D and 3D passing rates. Planned and measured dose distributions were evaluated on the patient's anatomy, using DVH and dose overlays. Minor deviations were detected, and the clinical significance of these are presented and discussed. CONCLUSIONS Two advantages accrue to the methods presented here. First, treatment accuracy is evaluated throughout the whole treated volume, yielding comprehensive verification. Second, the clinical significance of any deviations can be assessed through the generation of DVH curves and dose overlays on the patient's anatomy. The latter step represents an important development that advances the clinical relevance of complex treatment QA.
Collapse
MESH Headings
- Data Interpretation, Statistical
- Humans
- Imaging, Three-Dimensional/methods
- Meningeal Neoplasms/diagnostic imaging
- Meningeal Neoplasms/radiotherapy
- Meningioma/diagnostic imaging
- Meningioma/radiotherapy
- Neurilemmoma/diagnostic imaging
- Neurilemmoma/radiotherapy
- Neuroma, Acoustic/diagnostic imaging
- Neuroma, Acoustic/radiotherapy
- Organs at Risk/diagnostic imaging
- Phantoms, Imaging
- Quality Assurance, Health Care/methods
- Quality Assurance, Health Care/standards
- Radiography
- Radiometry/methods
- Radiotherapy Dosage
- Radiotherapy Planning, Computer-Assisted/methods
- Radiotherapy Planning, Computer-Assisted/standards
- Radiotherapy, Intensity-Modulated/methods
- Radiotherapy, Intensity-Modulated/standards
- Skull Base Neoplasms/diagnostic imaging
- Skull Base Neoplasms/radiotherapy
Collapse
Affiliation(s)
- Mark Oldham
- Radiation Oncology, Duke University Medical Center, Durham, North Carolina 27710, USA.
| | | | | | | | | | | | | |
Collapse
|
40
|
Han T, Mourtada F, Kisling K, Mikell J, Followill D, Howell R. Experimental validation of deterministic Acuros XB algorithm for IMRT and VMAT dose calculations with the Radiological Physics Center's head and neck phantom. Med Phys 2012; 39:2193-202. [PMID: 22482641 PMCID: PMC3337663 DOI: 10.1118/1.3692180] [Citation(s) in RCA: 60] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2011] [Revised: 01/09/2012] [Accepted: 02/14/2012] [Indexed: 11/07/2022] Open
Abstract
PURPOSE The purpose of this study was to verify the dosimetric performance of Acuros XB (AXB), a grid-based Boltzmann solver, in intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT). METHODS The Radiological Physics Center (RPC) head and neck (H&N) phantom was used for all calculations and measurements in this study. Clinically equivalent IMRT and VMAT plans were created on the RPC H&N phantom in the Eclipse treatment planning system (version 10.0) by using RPC dose prescription specifications. The dose distributions were calculated with two different algorithms, AXB 11.0.03 and anisotropic analytical algorithm (AAA) 10.0.24. Two dose report modes of AXB were recorded: dose-to-medium in medium (D(m,m)) and dose-to-water in medium (D(w,m)). Each treatment plan was delivered to the RPC phantom three times for reproducibility by using a Varian Clinac iX linear accelerator. Absolute point dose and planar dose were measured with thermoluminescent dosimeters (TLDs) and GafChromic® EBT2 film, respectively. Profile comparison and 2D gamma analysis were used to quantify the agreement between the film measurements and the calculated dose distributions from both AXB and AAA. The computation times for AAA and AXB were also evaluated. RESULTS Good agreement was observed between measured doses and those calculated with AAA or AXB. Both AAA and AXB calculated doses within 5% of TLD measurements in both the IMRT and VMAT plans. Results of AXB_D(m,m) (0.1% to 3.6%) were slightly better than AAA (0.2% to 4.6%) or AXB_D(w,m) (0.3% to 5.1%). The gamma analysis for both AAA and AXB met the RPC 7%/4 mm criteria (over 90% passed), whereas AXB_D(m,m) met 5%/3 mm criteria in most cases. AAA was 2 to 3 times faster than AXB for IMRT, whereas AXB was 4-6 times faster than AAA for VMAT. CONCLUSIONS AXB was found to be satisfactorily accurate when compared to measurements in the RPC H&N phantom. Compared with AAA, AXB results were equal to or better than those obtained with film measurements for IMRT and VMAT plans. The AXB_D(m,m) reporting mode was found to be closer to TLD and film measurements than was the AXB_D(w,m) mode. AXB calculation time was found to be significantly shorter (× 4) than AAA for VMAT.
Collapse
Affiliation(s)
- Tao Han
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
| | | | | | | | | | | |
Collapse
|
41
|
Disher B, Hajdok G, Gaede S, Battista JJ. An in-depth Monte Carlo study of lateral electron disequilibrium for small fields in ultra-low density lung: implications for modern radiation therapy. Phys Med Biol 2012; 57:1543-59. [DOI: 10.1088/0031-9155/57/6/1543] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
42
|
Gete E, Teke T, Kwa W. Evaluation of the AAA Treatment Planning Algorithm for SBRT Lung Treatment: Comparison with Monte Carlo and Homogeneous Pencil Beam Dose Calculations. J Med Imaging Radiat Sci 2012; 43:26-33. [DOI: 10.1016/j.jmir.2011.09.002] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2011] [Revised: 09/21/2011] [Accepted: 09/22/2011] [Indexed: 12/25/2022]
|
43
|
Ong CL, Cuijpers JP, Senan S, Slotman BJ, Verbakel WFAR. Impact of the calculation resolution of AAA for small fields and RapidArc treatment plans. Med Phys 2011; 38:4471-9. [PMID: 21928616 DOI: 10.1118/1.3605468] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE To investigate the impact of the calculation resolution of the anisotropic analytical algorithms (AAA) for a variety of small fields in homogeneous and heterogeneous media and for RapidArc plans. METHODS Dose distributions calculated using AAA version 8.6.15 (AAA8) and 10.0.25 (AAA10) were compared to measurements performed with GafChromic EBT film, using phantoms made of polystyrene or a combination of polystyrene and cork. The accuracy of the algorithms calculated using grid resolutions of 2.5 and 1.0 mm was investigated for different field sizes, and for a limited selection of RapidArc plans (head and neck, small meningioma, and lung). Additional plans were optimized to create excessive multileaf collimator modulation and measured on a homogenous phantom. Gamma evaluation criterion of 3% dose difference and 2- or 1-mm distance to agreement (DTA) were applied to evaluate the accuracy of the algorithms. RESULTS For fields < or = 3 x 3 cm2, both versions of AAA predicted lower peak doses and broader penumbra widths than the measurements. However, AAA10 and a finer calculation grid improved the agreement. For RapidArc plans with many small multileaf collimator (MLC) segments and relatively high number of monitor units (MU), AAA8 failed to identify small dose peaks within the target. Both versions performed better in polystyrene than in cork. In homogeneous cork layers, AAA8 underestimated the average target dose for a clinical lung plan. This was improved with AAA10 calculated using a 1 mm grid. CONCLUSIONS AAA10 improves the accuracy of dose calculations, and calculation grid of 1.0 mm is superior to using 2.5 mm, although calculation times increased by factor of 5. A suitable upper MU constraint should be assigned during optimization to avoid plans with high modulation. For plans with a relative high number of monitor units, calculations using 1 mm grid resolution are recommended. For planning target volume (PTV) which contains relatively large area of low density tissue, users should be aware of possible dose underestimation in the low density region and recalculation with AAA10 grid 1.0 mm is recommended.
Collapse
Affiliation(s)
- Chin Loon Ong
- Department of Radiation Oncology, Vu University Medical Center, 1081HV Amsterdam, The Netherlands
| | | | | | | | | |
Collapse
|
44
|
Han T, Mikell JK, Salehpour M, Mourtada F. Dosimetric comparison of Acuros XB deterministic radiation transport method with Monte Carlo and model-based convolution methods in heterogeneous media. Med Phys 2011; 38:2651-64. [PMID: 21776802 PMCID: PMC3107831 DOI: 10.1118/1.3582690] [Citation(s) in RCA: 149] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE The deterministic Acuros XB (AXB) algorithm was recently implemented in the Eclipse treatment planning system. The goal of this study was to compare AXB performance to Monte Carlo (MC) and two standard clinical convolution methods: the anisotropic analytical algorithm (AAA) and the collapsed-cone convolution (CCC) method. METHODS Homogeneous water and multilayer slab virtual phantoms were used for this study. The multilayer slab phantom had three different materials, representing soft tissue, bone, and lung. Depth dose and lateral dose profiles from AXB v10 in Eclipse were compared to AAA v10 in Eclipse, CCC in Pinnacle3, and EGSnrc MC simulations for 6 and 18 MV photon beams with open fields for both phantoms. In order to further reveal the dosimetric differences between AXB and AAA or CCC, three-dimensional (3D) gamma index analyses were conducted in slab regions and subregions defined by AAPM Task Group 53. RESULTS The AXB calculations were found to be closer to MC than both AAA and CCC for all the investigated plans, especially in bone and lung regions. The average differences of depth dose profiles between MC and AXB, AAA, or CCC was within 1.1, 4.4, and 2.2%, respectively, for all fields and energies. More specifically, those differences in bone region were up to 1.1, 6.4, and 1.6%; in lung region were up to 0.9, 11.6, and 4.5% for AXB, AAA, and CCC, respectively. AXB was also found to have better dose predictions than AAA and CCC at the tissue interfaces where backscatter occurs. 3D gamma index analyses (percent of dose voxels passing a 2%/2 mm criterion) showed that the dose differences between AAA and AXB are significant (under 60% passed) in the bone region for all field sizes of 6 MV and in the lung region for most of field sizes of both energies. The difference between AXB and CCC was generally small (over 90% passed) except in the lung region for 18 MV 10 x 10 cm2 fields (over 26% passed) and in the bone region for 5 x 5 and 10 x 10 cm2 fields (over 64% passed). With the criterion relaxed to 5%/2 mm, the pass rates were over 90% for both AAA and CCC relative to AXB for all energies and fields, with the exception of AAA 18 MV 2.5 x 2.5 cm2 field, which still did not pass. CONCLUSIONS In heterogeneous media, AXB dose prediction ability appears to be comparable to MC and superior to current clinical convolution methods. The dose differences between AXB and AAA or CCC are mainly in the bone, lung, and interface regions. The spatial distributions of these differences depend on the field sizes and energies.
Collapse
Affiliation(s)
- Tao Han
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030, USA
| | | | | | | |
Collapse
|
45
|
Alexander A, Soisson E, Hijal T, Sarfehnia A, Seuntjens J. Comparison of modulated electron radiotherapy to conventional electron boost irradiation and volumetric modulated photon arc therapy for treatment of tumour bed boost in breast cancer. Radiother Oncol 2011; 100:253-8. [PMID: 21741103 DOI: 10.1016/j.radonc.2011.05.081] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2011] [Revised: 05/20/2011] [Accepted: 05/23/2011] [Indexed: 11/26/2022]
Abstract
BACKGROUND AND PURPOSE To compare few leaf electron collimator (FLEC)-based modulated electron radiotherapy (MERT) to conventional direct electron (DE) and volumetric modulated photon arc therapy (VMAT) for the treatment of tumour bed boost in breast cancer. MATERIALS AND METHODS Fourteen patients with breast cancer treated by lumpectomy and requiring post-operative whole breast radiotherapy with tumour bed boost were planned retrospectively using conventional DE, VMAT and FLEC-based MERT. The planning goal was to deliver 10Gy to at least 95% of the tumour bed volume. Dosimetry parameters for all techniques were compared. RESULTS Dose evaluation volume (DEV) coverage and homogeneity were best for MERT (D(98)=9.77Gy, D(2)=11.03Gy) followed by VMAT (D(98)=9.56Gy, D(2)=11.07Gy) and DE (D(98)=9.81Gy, D(2)=11.52Gy). Relative to the DE plans, the MERT plans predicted a reduction of 35% in mean breast dose (p<0.05), 54% in mean lung dose (p<0.05) and 46% in mean body dose (p<0.05). Relative to the VMAT plans, the MERT plans predicted a reduction of 24%, 36% and 39% in mean breast dose, heart dose and body dose, respectively (p<0.05). CONCLUSIONS MERT plans were a considerable improvement in dosimetry over DE boost plans. There was a dosimetric advantage in using MERT over VMAT for increased DEV conformity and low-dose sparing of healthy tissue including the integral dose; however, the cost is often an increase in the ipsilateral lung high-dose volume.
Collapse
Affiliation(s)
- Andrew Alexander
- Medical Physics Unit, McGill University, Montreal, Quebec, Canada.
| | | | | | | | | |
Collapse
|
46
|
Taylor ML, Kron T, Franich RD. A contemporary review of stereotactic radiotherapy: inherent dosimetric complexities and the potential for detriment. Acta Oncol 2011; 50:483-508. [PMID: 21288161 DOI: 10.3109/0284186x.2010.551665] [Citation(s) in RCA: 51] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
OBJECTIVE The advantages of highly localised, conformal treatments achievable with stereotactic radiotherapy (SRT) are increasingly being extended to extracranial sites as stereotactic body radiotherapy with advancements in imaging and beam collimation. One of the challenges in stereotactic treatment lies in the significant complexities associated with small field dosimetry and dose calculation. This review provides a comprehensive overview of the complexities associated with stereotactic radiotherapy and the potential for detriment. METHODS This study is based on a comprehensive review of literature accessible via PubMed and other sources, covering stereotactic radiotherapy, small-field dosimetry and dose calculation. FINDINGS Several key issues were identified in the literature. They pertain to dose prescription, dose measurement and dose calculation within and beyond the treatment field. Field-edge regions and penumbrae occupy a significant portion of the total field size. Spectral and dosimetric characteristics are difficult to determine and are compounded by effects of tissue inhomogeneity. Measurement of small-fields is made difficult by detector volume averaging and energy response. Available dosimeters are compared, and emphasis is given to gel dosimetry which offers the greatest potential for three-dimensional small-field dosimetry. The limitations of treatment planning system algorithms as applied to small-fields (particularly in the presence of heterogeneities) is explained, and a review of Monte Carlo dose calculation is provided, including simplified treatment planning implementations. Not incorporated into treatment planning, there is evidence that far from the primary field, doses to patients (and corresponding risks of radiocarcinogenesis) from leakage/scatter in SRT are similar to large fields. CONCLUSIONS Improved knowledge of dosimetric issues is essential to the accurate measurement and calculation of dose as well as the interpretation and assessment of planned and delivered treatments. This review highlights such issues and the potential benefit that may be gained from Monte Carlo dose calculation and verification via three-dimensional dosimetric methods (such as gel dosimetry) being introduced into routine clinical practice.
Collapse
Affiliation(s)
- Michael L Taylor
- School of Applied Sciences, RMIT University, Melbourne, Victoria, Australia.
| | | | | |
Collapse
|
47
|
Interfractional dose variations in intensity-modulated radiotherapy with breath-hold for pancreatic cancer. Int J Radiat Oncol Biol Phys 2011; 82:1619-26. [PMID: 21477941 DOI: 10.1016/j.ijrobp.2011.01.050] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2010] [Revised: 12/28/2010] [Accepted: 01/12/2011] [Indexed: 12/25/2022]
Abstract
PURPOSE To investigate the interfractional dose variations for intensity-modulated radiotherapy (RT) combined with breath-hold (BH) at end-exhalation (EE) for pancreatic cancer. METHODS AND MATERIALS A total of 10 consecutive patients with pancreatic cancer were enrolled. Each patient was fixed in the supine position on an individualized vacuum pillow with both arms raised. Computed tomography (CT) scans were performed before RT, and three additional scans were performed during the course of chemoradiotherapy using a conventional RT technique. The CT data were acquired under EE-BH conditions (BH-CT) using a visual feedback technique. The intensity-modulated RT plan, which used five 15-MV coplanar ports, was designed on the initial BH-CT set with a prescription dose of 39 Gy at 2.6 Gy/fraction. After rigid image registration between the initial and subsequent BH-CT scans, the dose distributions were recalculated on the subsequent BH-CT images under the same conditions as in planning. Changes in the dose-volume metrics of the gross tumor volume (GTV), clinical target volume (CTV = GTV + 5 mm), stomach, and duodenum were evaluated. RESULTS For the GTV and clinical target volume (CTV), the 95th percentile of the interfractional variations in the maximal dose, mean dose, dose covering 95% volume of the region of structure, and percentage of the volume covered by the 90% isodose line were within ±3%. Although the volume covered by the 39 Gy isodose line for the stomach and duodenum did not exceed 0.1 mL at planning, the volume covered by the 39 Gy isodose line for these structures was up to 11.4 cm(3) and 1.8 cm(3), respectively. CONCLUSIONS Despite variations in the gastrointestinal state and abdominal wall position at EE, the GTV and CTV were mostly ensured at the planned dose, with the exception of 1 patient. Compared with the duodenum, large variations in the stomach volume receiving high-dose radiation were observed, which might be beyond the negligible range in achieving dose escalation with intensity-modulated RT combined with BH at EE.
Collapse
|
48
|
Sterpin E, Chen Y, Lu W, Mackie TR, Olivera GH, Vynckier S. On the relationships between electron spot size, focal spot size, and virtual source position in Monte Carlo simulations. Med Phys 2011; 38:1579-86. [DOI: 10.1118/1.3556560] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
49
|
Rong Y, Tang G, Welsh JS, Mohiuddin MM, Paliwal B, Yu CX. Helical tomotherapy versus single-arc intensity-modulated arc therapy: a collaborative dosimetric comparison between two institutions. Int J Radiat Oncol Biol Phys 2011; 81:284-96. [PMID: 21236598 DOI: 10.1016/j.ijrobp.2010.10.059] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2010] [Revised: 10/22/2010] [Accepted: 10/28/2010] [Indexed: 10/18/2022]
Abstract
PURPOSE Both helical tomotherapy (HT) and single-arc intensity-modulated arc therapy (IMAT) deliver radiation using rotational beams with multileaf collimators. We report a dual-institution study comparing dosimetric aspects of these two modalities. METHODS AND MATERIALS Eight patients each were selected from the University of Maryland (UMM) and the University of Wisconsin Cancer Center Riverview (UWR), for a total of 16 cases. Four cancer sites including brain, head and neck (HN), lung, and prostate were selected. Single-arc IMAT plans were generated at UMM using Varian RapidArc (RA), and HT plans were generated at UWR using Hi-Art II TomoTherapy. All 16 cases were planned based on the identical anatomic contours, prescriptions, and planning objectives. All plans were swapped for analysis at the same time after final approval. Dose indices for targets and critical organs were compared based on dose-volume histograms, the beam-on time, monitor units, and estimated leakage dose. After the disclosure of comparison results, replanning was done for both techniques to minimize diversity in optimization focus from different operators. RESULTS For the 16 cases compared, the average beam-on time was 1.4 minutes for RA and 4.8 minutes for HT plans. HT provided better target dose homogeneity (7.6% for RA and 4.2% for HT) with a lower maximum dose (110% for RA and 105% for HT). Dose conformation numbers were comparable, with RA being superior to HT (0.67 vs. 0.60). The doses to normal tissues using these two techniques were comparable, with HT showing lower doses for more critical structures. After planning comparison results were exchanged, both techniques demonstrated improvements in dose distributions or treatment delivery times. CONCLUSIONS Both techniques created highly conformal plans that met or exceeded the planning goals. The delivery time and total monitor units were lower in RA than in HT plans, whereas HT provided higher target dose uniformity.
Collapse
Affiliation(s)
- Yi Rong
- Department of Human Oncology and Medical Physics, University of Wisconsin-Madison, Madison, WI, USA.
| | | | | | | | | | | |
Collapse
|
50
|
Aristophanous M, Rottmann J, Court LE, Berbeco RI. EPID-guided 3D dose verification of lung SBRT. Med Phys 2010; 38:495-503. [DOI: 10.1118/1.3532821] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|