1
|
Sun W, Zhang J, Wang Y, Chen M, Wang J, Chen L, Lu L, Deng X. Comparison of Absolute Dose Achievable Between Helical Tomotherapy and RapidArc in Total Dura Mater Irradiation for Child Cancer. Technol Cancer Res Treat 2022; 21:15330338211072680. [PMID: 35023424 PMCID: PMC8785325 DOI: 10.1177/15330338211072680] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
Background and Purpose: In this study, the absolute dose achievable between helical tomotherapy (HT) plans and RapidArc (RA) plans for total dura mater irradiation (TDMI) was compared. Materials and methods: A planning study was conducted on nine children's case datasets with dura mater metastasis of neuroblastoma. The target included the entire calvarium and skull base and formed a closed volume with a certain thickness around the brain. HT and RA plans with four coplanar full arcs (RA4) with half-field technique were generated for the comparison of absolute dose achievable. In total, 30.6 Gy was prescribed as D95% (ie, dose to 95% of PTV volume). Results: In the dosimetric comparison between the two modalities, HT provided more homogenous dose distribution than RA4 (mean HI5−95%: 1.046 vs 1.088, P < .001). The V107% and D2Gy of PTV in HT versus RA4 were 3.06% versus 30.47% and 32.59 Gy versus 33.45 Gy, respectively. HT reduced the Dmean and V5Gy of the brain, brainstem, and hippocampus by 25%–48% and 27%–56% compared with RA4, respectively. Conclusion: Both techniques could provide sufficient coverage for targets, but HT offered more homogenous dose to PTV and lower dose to the central region of the brain involving the brainstem and hippocampus. RA4 could be completed in a shorter time with lower MUs, but with relatively higher dose to the brain or hippocampus. In terms of dosimetry, HT may improve long-term cognitive decline in these young pediatric patients with TDMI.
Collapse
Affiliation(s)
- Wenzhao Sun
- 71067State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center, Guangzhou, China.,Guangdong Esophageal Cancer Institute, Guangzhou, China
| | - Jun Zhang
- 71067State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Yixuan Wang
- 71067State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Meining Chen
- 71067State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center, Guangzhou, China
| | | | - Li Chen
- 71067State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center, Guangzhou, China.,Guangdong Esophageal Cancer Institute, Guangzhou, China
| | - Lixia Lu
- 71067State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Xiaowu Deng
- 71067State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center, Guangzhou, China
| |
Collapse
|
2
|
Feasibility of tomotherapy-based image-guided radiotherapy for locally advanced oropharyngeal cancer. PLoS One 2013; 8:e60268. [PMID: 23555938 PMCID: PMC3610680 DOI: 10.1371/journal.pone.0060268] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2012] [Accepted: 02/25/2013] [Indexed: 11/19/2022] Open
Abstract
Purpose The study aims to assess the feasibility of tomotherapy-based image-guided (IGRT) radiotherapy for locally advanced oropharyngeal cancer. A retrospective review of 33 patients undergoing concurrent chemoradiation for locally advanced oropharyngeal cancers was conducted. Radiotherapy planning, treatment toxicity and loco-regional control were assessed. Results At a median follow-up of 32 months (6–47 months), no patient developed loco-regional recurrence. Two patients (6%) developed distant metastases. Grade 3–4 acute toxicity was respectively 72% and 25% for mucositis and gastrointestinal toxicity. Two patients (6%) had long-term dependence on tube feedings. Dose-volume histogram demonstrated excellent target volume coverage and low radiation dose to the organs at risk for complications. Conclusions and clinical relevance IGRT provides excellent loco-regional control but acute toxicity remains significant and needs to be addressed in future prospective trials. The feasibility of Tomotherapy to decrease radiation dose to the normal tissues merits further investigations.
Collapse
|
3
|
Pardo-Montero J, Fenwick JD. Tomotherapy-like versus VMAT-like treatments: a multicriteria comparison for a prostate geometry. Med Phys 2013; 39:7418-29. [PMID: 23231292 DOI: 10.1118/1.4768159] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE To perform a methodological comparison of volumetric modulated arc therapy (VMAT)-like and tomotherapy-like techniques for a prostate geometry, exploring the dependence on machine, delivery, and optimization parameters of cost function values optimized for each technique. METHODS A gradient-descent algorithm is used to optimize tomotherapy-like treatments, while VMAT-like optimization is carried out using a direct-aperture simulated annealing algorithm with 180 control points equispaced at 2° angles. Dose distributions are linked to fluences via a three-dimensional double-gaussian pencil beam model. Plans are optimized for a prostate geometry, outlined according to the CHHiP protocol. The cost function used for optimization contains ten simple functions, each of which describes a single planning objective. These functions are split into three structure groups according to whether they are used to control PTV, rectal or bladder dose levels. Different optimizations have been performed by varying the relative weights of each of these structure groups, exploring in this way a three-dimensional Pareto front. Plan quality is studied according to the value of the optimized cost function and the relative Euclidean distance between the components of the cost function and those of the nearest plan lying on a reference Pareto front obtained for tomotherapy-like plans generated using a 1 cm fan-beam width and 1/3 pitch. RESULTS The quality of tomotherapy-like optimization depends on the fan-beam width, s, and rotation pitch, p, used to deliver the treatment. These values together define the effective longitudinal resolution with which fluence can be modulated, and lower cost function values are obtained for treatments optimized with tighter pitches and narrower fan-beam widths (higher modulation resolution). On the other hand, the cost function values of VMAT-like optimizations depends on the optimization running time, leaf displacement constraints, and number of arcs employed, as well as on the size of the beamlets used in the optimization (a change in leaf width from 5 to 10 mm clearly worsens the value of the objective function, but only a marginal improvement is observed when the leaf movement discretization step is reduced from 5 to 5/3 mm). However, for no combination of these parameter values did VMAT-like optimizations match the cost function values of optimized tomo-like plans obtained for s = 1 cm and p = 1∕3 (or 1/2). This is the case all across the Pareto front. On the other hand, cost function values of VMAT-like plans are generally lower than those of optimized tomotherapy-like plans obtained for s = 2.5 cm. CONCLUSIONS Tomotherapy-like plans created for the prostate geometry using a 1 cm fan-beam width and pitches of 1/3 or 1/2 have lower cost function values than VMAT-like plans, although the associated dosimetric improvements are quite small, both techniques generating very good dose distributions. When a 2.5 cm wide fan-beam is used for tomotherapy-like treatments the pattern is reversed, the tomotherapy-like plans having higher cost functions than the VMAT-like ones.
Collapse
Affiliation(s)
- Juan Pardo-Montero
- Departamento de Física de Partículas, Universidade de Santiago de Compostela, Santiago de Compostela, Spain.
| | | |
Collapse
|
4
|
Betzel GT, Yi BY, Niu Y, Yu CX. Is RapidArc more susceptible to delivery uncertainties than dynamic IMRT? Med Phys 2012; 39:5882-90. [PMID: 23039627 PMCID: PMC3461049 DOI: 10.1118/1.4749965] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2012] [Revised: 08/19/2012] [Accepted: 08/20/2012] [Indexed: 11/07/2022] Open
Abstract
PURPOSE Rotational IMRT has been adopted by many clinics for its promise to deliver treatments in a shorter amount of time than other conventional IMRT techniques. In this paper, the authors investigate whether RapidArc is more susceptible to delivery uncertainties than dynamic IMRT using fixed fields. METHODS Dosimetric effects of delivery uncertainties in dose rate, gantry angle, and MLC leaf positions were evaluated by incorporating these uncertainties into RapidArc and sliding window IMRT (SW IMRT) treatment plans for five head-and-neck and five prostate cases. Dose distributions and dose-volume histograms of original and modified plans were recalculated and compared using Gamma analysis and dose indices of planned treatment volumes (PTV) and organs at risk (OAR). Results of Gamma analyses using passing criteria ranging from 1%-1 mm up to 5%-3 mm were reported. RESULTS Systematic shifts in MLC leaf bank positions of SW-IMRT cases resulted in 2-4 times higher average percent differences than RapidArc cases. Uniformly distributed random variations of 2 mm for active MLC leaves had a negligible effect on all dose distributions. Sliding window cases were much more sensitive to systematic shifts in gantry angle. Dose rate variations during RapidArc must be much larger than typical machine tolerances to affect dose distributions significantly; dynamic IMRT is inherently not susceptible to such variations. CONCLUSIONS RapidArc deliveries were found to be more tolerant to variations in gantry position and MLC leaf position than SW IMRT. This may be attributed to the fact that the average segmental field size or MLC leaf opening is much larger for RapidArc. Clinically acceptable treatments may be delivered successfully using RapidArc despite large fluctuations in dose rate and gantry position.
Collapse
Affiliation(s)
- Gregory T Betzel
- Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, MD, USA
| | | | | | | |
Collapse
|
5
|
Tsai CL, Wu JK, Chao HL, Tsai YC, Cheng JCH. Treatment and Dosimetric Advantages Between VMAT, IMRT, and Helical TomoTherapy in Prostate Cancer. Med Dosim 2011; 36:264-71. [PMID: 20634054 DOI: 10.1016/j.meddos.2010.05.001] [Citation(s) in RCA: 70] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2010] [Revised: 04/21/2010] [Accepted: 05/10/2010] [Indexed: 11/25/2022]
|
6
|
Murthy V, Mallik S, Master Z, Sharma PK, Mahantshetty U, Shrivastava SK. Does Helical Tomotherapy Improve Dose Conformity and Normal Tissue Sparing Compared to Conventional IMRT? A Dosimetric Comparison in High Risk Prostate Cancer. Technol Cancer Res Treat 2011; 10:179-85. [DOI: 10.7785/tcrt.2012.500193] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
The study was designed to compare Helical Tomotherapy (HT) based IMRT and conventional sliding window (SW IMRT) in patients with high risk prostate cancer. Complementary plans with HT and SWIMRT were compared using DVH parameters. The PTV Prostate was prescribed 74 Gy in 37 fractions and the nodal PTV received 55 Gy in 37 fractions by simultaneous integrated boost. Conformity Index, Homogeneity Index and dose-volume parameters were compared. The conformity index (CI) of HT (0.77, SD = 0.54) plans tended to be better (p = 0.069) compared to SWIMRT (0.70, SD = 0.01) for prostate PTV. CI for nodal PTV was similar. Helical tomotherapy plans were more homogeneous, with homogeneity index (HI) of 0.04 compared to 0.06 in SWIMRT (p = 0.018) for PTV prostate and HI of 0.06 and 0.15 (p = 0.025) for PTV nodes respectively. Median dose to bladder (p = 0.025) and rectum (p = 0.012) were less with HT. However, HT delivered a higher D10Gy and D1Gy to rectum and bladder overlap volumes as a consequence of achieving better homogeneity. Femoral heads were better spared with HT plans (p = 0.012). HT improves dose homogeneity, target coverage and conformity as compared to SWIMRT, with overall improvement in critical organ sparing.
Collapse
Affiliation(s)
- V. Murthy
- Dept of Radiation Oncology, Tata Memorial Hospital and Advanced Centre for Treatment Research and Education in Cancer (ACTREC), Tata Memorial Centre, Mumbai, 410210 India
| | - S. Mallik
- Dept of Radiation Oncology, Tata Memorial Hospital and Advanced Centre for Treatment Research and Education in Cancer (ACTREC), Tata Memorial Centre, Mumbai, 410210 India
| | - Z. Master
- Dept of Radiation Oncology, Tata Memorial Hospital and Advanced Centre for Treatment Research and Education in Cancer (ACTREC), Tata Memorial Centre, Mumbai, 410210 India
| | - P. K. Sharma
- Dept of Radiation Oncology, Tata Memorial Hospital and Advanced Centre for Treatment Research and Education in Cancer (ACTREC), Tata Memorial Centre, Mumbai, 410210 India
| | - U. Mahantshetty
- Dept of Radiation Oncology, Tata Memorial Hospital and Advanced Centre for Treatment Research and Education in Cancer (ACTREC), Tata Memorial Centre, Mumbai, 410210 India
| | - S. K. Shrivastava
- Dept of Radiation Oncology, Tata Memorial Hospital and Advanced Centre for Treatment Research and Education in Cancer (ACTREC), Tata Memorial Centre, Mumbai, 410210 India
| |
Collapse
|
7
|
Chatterjee S, Mott JH, Smyth G, Dickson S, Dobrowsky W, Kelly CG. Clinical challenges in the implementation of a tomotherapy service for head and neck cancer patients in a regional UK radiotherapy centre. Br J Radiol 2011; 84:358-66. [PMID: 21159810 PMCID: PMC3473475 DOI: 10.1259/bjr/19586137] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2010] [Revised: 02/16/2010] [Accepted: 02/16/2010] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVE Intensity-modulated radiotherapy (IMRT) is increasingly being used to treat head and neck cancer cases. METHODS We discuss the clinical challenges associated with the setting up of an image guided intensity modulated radiotherapy service for a subset of head and neck cancer patients, using a recently commissioned helical tomotherapy (HT) Hi Art (Tomotherapy Inc, WI) machine in this article. We also discuss the clinical aspects of the tomotherapy planning process, treatment and image guidance experiences for the first 10 head and neck cancer cases. The concepts of geographical miss along with tomotherapy-specific effects, including that of field width and megavoltage CT (MVCT) imaging strategy, have been highlighted using the first 10 head and neck cases treated. RESULTS There is a need for effective streamlining of all aspects of the service to ensure compliance with cancer waiting time targets. We discuss how patient toxicity audits are crucial to guide refinement of the newly set-up planning dose constraints. CONCLUSION This article highlights the important clinical issues one must consider when setting up a head and neck IMRT, image-guided radiotherapy service. It shares some of the clinical challenges we have faced during the setting up of a tomotherapy service. Implementation of a clinical tomotherapy service requires a multidisciplinary team approach and relies heavily on good team working and effective communication between different staff groups.
Collapse
Affiliation(s)
- S Chatterjee
- Northern Centre for Cancer Care, Freeman Hospital, Freeman Road, Newcastle upon Tyne NE7 7DN, UK.
| | | | | | | | | | | |
Collapse
|
8
|
Sun B, Rangaraj D, Papiez L, Oddiraju S, Yang D, Li HH. Target tracking using DMLC for volumetric modulated arc therapy: a simulation study. Med Phys 2011; 37:6116-24. [PMID: 21302768 DOI: 10.1118/1.3511516] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
PURPOSE Target tracking using dynamic multileaf collimator (DMLC) is a promising approach for intrafraction motion management in radiation therapy. The purpose of this work is to develop a DMLC tracking algorithm capable of delivering volumetric-modulated arc therapy (VMAT) to the targets that experience two-dimensional (2D) rigid motion in the beam's eye view. METHODS The problem of VMAT delivery to moving targets is formulated as a control problem with constraints. The relationships between gantry speed, gantry acceleration, MLC leaf-velocity, dose rate, and target motion are derived. An iterative search algorithm is developed to find numerical solutions for efficient delivery of a specific VMAT plan to the moving target using 2D DMLC tracking. The delivery of five VMAT lung plans is simulated. The planned and delivered fluence maps in the target-reference frame are calculated and compared. RESULTS The simulation demonstrates that the 2D tracking algorithm is capable of delivering the VMAT plan to a moving target fast and accurately without violating the machine constraints and the integrity of the treatment plan. The average delivery time is only 29 s longer than that of no-tracking delivery, 101 versus 72 s, respectively. The fluence maps are normalized to 200 MU and the average root-mean-square error between the desired and the delivered fluence is 2.1 MU, compared to 14.8 MU for no-tracking and 3.6 MU for one-dimensional tracking. CONCLUSIONS A locally optimal MLC tracking algorithm for VMAT delivery is proposed, aiming at shortest delivery time while maintaining treatment plan invariant. The inconsequential increase of treatment time due to DMLC tracking is clinically desirable, which makes VMAT with DMLC tracking attractive in treating moving tumors.
Collapse
Affiliation(s)
- Baozhou Sun
- Department of Radiation Oncology, School of Medicine, Washington University, 4921 Parkview Place, St. Louis, Missouri 63110, USA
| | | | | | | | | | | |
Collapse
|
9
|
Elith C, Dempsey SE, Findlay N, Warren-Forward HM. An Introduction to the Intensity-modulated Radiation Therapy (IMRT) Techniques, Tomotherapy, and VMAT. J Med Imaging Radiat Sci 2011; 42:37-43. [DOI: 10.1016/j.jmir.2010.11.005] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2010] [Accepted: 11/10/2010] [Indexed: 12/31/2022]
|
10
|
Rong Y, Tang G, Welsh JS, Mohiuddin MM, Paliwal B, Yu CX. Helical tomotherapy versus single-arc intensity-modulated arc therapy: a collaborative dosimetric comparison between two institutions. Int J Radiat Oncol Biol Phys 2011; 81:284-96. [PMID: 21236598 DOI: 10.1016/j.ijrobp.2010.10.059] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2010] [Revised: 10/22/2010] [Accepted: 10/28/2010] [Indexed: 10/18/2022]
Abstract
PURPOSE Both helical tomotherapy (HT) and single-arc intensity-modulated arc therapy (IMAT) deliver radiation using rotational beams with multileaf collimators. We report a dual-institution study comparing dosimetric aspects of these two modalities. METHODS AND MATERIALS Eight patients each were selected from the University of Maryland (UMM) and the University of Wisconsin Cancer Center Riverview (UWR), for a total of 16 cases. Four cancer sites including brain, head and neck (HN), lung, and prostate were selected. Single-arc IMAT plans were generated at UMM using Varian RapidArc (RA), and HT plans were generated at UWR using Hi-Art II TomoTherapy. All 16 cases were planned based on the identical anatomic contours, prescriptions, and planning objectives. All plans were swapped for analysis at the same time after final approval. Dose indices for targets and critical organs were compared based on dose-volume histograms, the beam-on time, monitor units, and estimated leakage dose. After the disclosure of comparison results, replanning was done for both techniques to minimize diversity in optimization focus from different operators. RESULTS For the 16 cases compared, the average beam-on time was 1.4 minutes for RA and 4.8 minutes for HT plans. HT provided better target dose homogeneity (7.6% for RA and 4.2% for HT) with a lower maximum dose (110% for RA and 105% for HT). Dose conformation numbers were comparable, with RA being superior to HT (0.67 vs. 0.60). The doses to normal tissues using these two techniques were comparable, with HT showing lower doses for more critical structures. After planning comparison results were exchanged, both techniques demonstrated improvements in dose distributions or treatment delivery times. CONCLUSIONS Both techniques created highly conformal plans that met or exceeded the planning goals. The delivery time and total monitor units were lower in RA than in HT plans, whereas HT provided higher target dose uniformity.
Collapse
Affiliation(s)
- Yi Rong
- Department of Human Oncology and Medical Physics, University of Wisconsin-Madison, Madison, WI, USA.
| | | | | | | | | | | |
Collapse
|