Ramos-Mendez J, Ortiz CR, Schuemann J, Paganetti H, Faddegon B. TOPAS simulation of photoneutrons in radiotherapy: accuracy and speed with variance reduction. Phys Med Biol 2024; 69:10.1088/1361-6560/ad4303. [PMID: 38657630 PMCID: PMC467037 DOI: 10.1088/1361-6560/ad4303] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2024] [Accepted: 04/24/2024] [Indexed: 04/26/2024]
Abstract
Objective. We provide optimal particle split numbers for speeding up TOPAS Monte Carlo simulations of linear accelerator (linac) treatment heads while maintaining accuracy. In addition, we provide a new TOPAS physics module for simulating photoneutron production and transport.Approach.TOPAS simulation of a Siemens Oncor linac was used to determine the optimal number of splits for directional bremsstrahlung splitting as a function of the field size for 6 MV and 18 MV x-ray beams. The linac simulation was validated against published data of lateral dose profiles and percentage depth-dose curves (PDD) for the largest square field (40 cm side). In separate simulations, neutron particle split and the custom TOPAS physics module was used to generate and transport photoneutrons, called 'TsPhotoNeutron'. Verification of accuracy was performed by comparing simulations with published measurements of: (1) neutron yields as a function of beam energy for thick targets of Al, Cu, Ta, W, Pb and concrete; and (2) photoneutron energy spectrum at 40 cm laterally from the isocenter of the Oncor linac from an 18 MV beam with closed jaws and MLC.Main results.The optimal number of splits obtained for directional bremsstrahlung splitting enhanced the computational efficiency by two orders of magnitude. The efficiency decreased with increasing beam energy and field size. Calculated lateral profiles in the central region agreed within 1 mm/2% from measured data, PDD curves within 1 mm/1%. For the TOPAS physics module, at a split number of 146, the efficiency of computing photoneutron yields was enhanced by a factor of 27.6, whereas it improved the accuracy over existing Geant4 physics modules.Significance.This work provides simulation parameters and a new TOPAS physics module to improve the efficiency and accuracy of TOPAS simulations that involve photonuclear processes occurring in high-Zmaterials found in linac components, patient devices, and treatment rooms, as well as to explore new therapeutic modalities such as very-high energy electron therapy.
Collapse
Affiliation(s)
- J Ramos-Mendez
- Department of Radiation Oncology, University of California San Francisco, San Francisco CA, United States of America
| | - Catalan R Ortiz
- Department of Radiation Oncology, University of California San Francisco, San Francisco CA, United States of America
| | - J Schuemann
- Department of Radiation Oncology, Physics Division, Massachusetts General Hospital & Harvard Medical School, Boston MA, United States of America
| | - H Paganetti
- Department of Radiation Oncology, Physics Division, Massachusetts General Hospital & Harvard Medical School, Boston MA, United States of America
| | - B Faddegon
- Department of Radiation Oncology, University of California San Francisco, San Francisco CA, United States of America
| |
Collapse
|
2
|
Ramos-Méndez J, Domínguez-Kondo N, Schuemann J, McNamara A, Moreno-Barbosa E, Faddegon B. LET-Dependent Intertrack Yields in Proton Irradiation at Ultra-High Dose Rates Relevant for FLASH Therapy. Radiat Res 2020; 194:351-362. [PMID: 32857855 PMCID: PMC7644138 DOI: 10.1667/rade-20-00084.1] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2020] [Accepted: 07/13/2020] [Indexed: 01/01/2023]
Abstract
FLASH radiotherapy delivers a high dose (≥10 Gy) at a high rate (≥40 Gy/s). In this way, particles are delivered in pulses as short as a few nanoseconds. At that rate, intertrack reactions between chemical species produced within the same pulse may affect the heterogeneous chemistry stage of water radiolysis. This stochastic process suits the capabilities of the Monte Carlo method, which can model intertrack effects to aid in radiobiology research, including the design and interpretation of experiments. In this work, the TOPAS-nBio Monte Carlo track-structure code was expanded to allow simulations of intertrack effects in the chemical stage of water radiolysis. Simulation of the behavior of radiolytic yields over a long period of time (up to 50 s) was verified by simulating radiolysis in a Fricke dosimeter irradiated by 60Co γ rays. In addition, LET-dependent G values of protons delivered in single squared pulses of widths, 1 ns, 1 µs and 10 µs, were obtained and compared to simulations using no intertrack considerations. The Fricke simulation for the calculated G value of Fe3+ ion at 50 s was within 0.4% of the accepted value from ICRU Report 34. For LET-dependent G values at the end of the chemical stage, intertrack effects were significant at LET values below 2 keV/µm. Above 2 keV/µm the reaction kinetics remained limited locally within each track and thus, effects of intertrack reactions remained low. Therefore, when track structure simulations are used to investigate the biological damage of FLASH irradiation, these intertrack reactions should be considered. The TOPAS-nBio framework with the expansion to intertrack chemistry simulation provides a useful tool to assist in this task.
Collapse
Affiliation(s)
- J. Ramos-Méndez
- Department of Radiation Oncology, University of California San Francisco, San Francisco, California
| | - N. Domínguez-Kondo
- Facultad de Ciencias Físico-Matemáticas, Benemérita Universidad Autónoma de Puebla, Puebla, Mexico
| | - J. Schuemann
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts
| | - A. McNamara
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts
| | - E. Moreno-Barbosa
- Facultad de Ciencias Físico-Matemáticas, Benemérita Universidad Autónoma de Puebla, Puebla, Mexico
| | - Bruce Faddegon
- Department of Radiation Oncology, University of California San Francisco, San Francisco, California
| |
Collapse
|
3
|
Ma CMC, Chetty IJ, Deng J, Faddegon B, Jiang SB, Li J, Seuntjens J, Siebers JV, Traneus E. Beam modeling and beam model commissioning for Monte Carlo dose calculation-based radiation therapy treatment planning: Report of AAPM Task Group 157. Med Phys 2019; 47:e1-e18. [PMID: 31679157 DOI: 10.1002/mp.13898] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2019] [Revised: 10/01/2019] [Accepted: 10/18/2019] [Indexed: 11/07/2022] Open
Abstract
Dose calculation plays an important role in the accuracy of radiotherapy treatment planning and beam delivery. The Monte Carlo (MC) method is capable of achieving the highest accuracy in radiotherapy dose calculation and has been implemented in many commercial systems for radiotherapy treatment planning. The objective of this task group was to assist clinical physicists with the potentially complex task of acceptance testing and commissioning MC-based treatment planning systems (TPS) for photon and electron beam dose calculations. This report provides an overview on the general approach of clinical implementation and testing of MC-based TPS with a specific focus on models of clinical photon and electron beams. Different types of beam models are described including those that utilize MC simulation of the treatment head and those that rely on analytical methods and measurements. The trade-off between accuracy and efficiency in the various source-modeling approaches is discussed together with guidelines for acceptance testing of MC-based TPS from the clinical standpoint. Specific recommendations are given on methods and practical procedures to commission clinical beam models for MC-based TPS.
Collapse
Affiliation(s)
- Chang Ming Charlie Ma
- Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA, 19111, USA
| | - Indrin J Chetty
- Radiation Oncology Department, Henry Ford Health System, Detroit, MI, 48188, USA
| | - Jun Deng
- Department of Therapeutic Radiology, Yale University, New Haven, CT, 06032, USA
| | - Bruce Faddegon
- Department of Radiation Oncology, UCSF, San Francisco, CA, 94143, USA
| | - Steve B Jiang
- Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX, 75390, USA
| | | | - Jan Seuntjens
- Medical Physics Unit, McGill University, Montreal, QC, H4A 3J1, Canada
| | - Jeffrey V Siebers
- Department of Radiation Oncology, University of Virginia, Charlottesville, VA, 22908, USA
| | - Erik Traneus
- RaySearch Laboratories AB, SE-103 65, Stockholm, Sweden
| |
Collapse
|
4
|
Geng C, Moteabbed M, Seco J, Gao Y, George Xu X, Ramos-Méndez J, Faddegon B, Paganetti H. Dose assessment for the fetus considering scattered and secondary radiation from photon and proton therapy when treating a brain tumor of the mother. Phys Med Biol 2015; 61:683-95. [DOI: 10.1088/0031-9155/61/2/683] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
|
5
|
Ramos-Méndez J, Perl J, Schümann J, Shin J, Paganetti H, Faddegon B. A framework for implementation of organ effect models in TOPAS with benchmarks extended to proton therapy. Phys Med Biol 2015; 60:5037-52. [PMID: 26061583 DOI: 10.1088/0031-9155/60/13/5037] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
The aim of this work was to develop a framework for modeling organ effects within TOPAS (TOol for PArticle Simulation), a wrapper of the Geant4 Monte Carlo toolkit that facilitates particle therapy simulation. The DICOM interface for TOPAS was extended to permit contour input, used to assign voxels to organs. The following dose response models were implemented: The Lyman-Kutcher-Burman model, the critical element model, the population based critical volume model, the parallel-serial model, a sigmoid-based model of Niemierko for normal tissue complication probability and tumor control probability (TCP), and a Poisson-based model for TCP. The framework allows easy manipulation of the parameters of these models and the implementation of other models. As part of the verification, results for the parallel-serial and Poisson model for x-ray irradiation of a water phantom were compared to data from the AAPM Task Group 166. When using the task group dose-volume histograms (DVHs), results were found to be sensitive to the number of points in the DVH, with differences up to 2.4%, some of which are attributable to differences between the implemented models. New results are given with the point spacing specified. When using Monte Carlo calculations with TOPAS, despite the relatively good match to the published DVH's, differences up to 9% were found for the parallel-serial model (for a maximum DVH difference of 2%) and up to 0.5% for the Poisson model (for a maximum DVH difference of 0.5%). However, differences of 74.5% (in Rectangle1), 34.8% (in PTV) and 52.1% (in Triangle) for the critical element, critical volume and the sigmoid-based models were found respectively. We propose a new benchmark for verification of organ effect models in proton therapy. The benchmark consists of customized structures in the spread out Bragg peak plateau, normal tissue, tumor, penumbra and in the distal region. The DVH's, DVH point spacing, and results of the organ effect models are provided. The models were used to calculate dose response for a Head and Neck patient to demonstrate functionality of the new framework and indicate the degree of variability between the models in proton therapy.
Collapse
Affiliation(s)
- J Ramos-Méndez
- Deparment of Radiation Oncology, University of California at San Francisco, San Francisco, CA 94143, USA
| | | | | | | | | | | |
Collapse
|
6
|
Monte Carlo Simulation of Siemens ONCOR Linear Accelerator with BEAMnrc and DOSXYZnrc Code. JOURNAL OF MEDICAL SIGNALS AND SENSORS 2013; 3:172-9. [PMID: 24672765 PMCID: PMC3959007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/12/2013] [Accepted: 07/19/2013] [Indexed: 11/12/2022]
Abstract
The Monte Carlo method is the most accurate method for simulation of radiation therapy equipment. The linear accelerators (linac) are currently the most widely used machines in radiation therapy centers. In this work, a Monte Carlo modeling of the Siemens ONCOR linear accelerator in 6 MV and 18 MV beams was performed. The results of simulation were validated by measurements in water by ionization chamber and extended dose range (EDR2) film in solid water. The linac's X-ray particular are so sensitive to the properties of primary electron beam. Square field size of 10 cm × 10 cm produced by the jaws was compared with ionization chamber and film measurements. Head simulation was performed with BEAMnrc and dose calculation with DOSXYZnrc for film measurements and 3ddose file produced by DOSXYZnrc analyzed used homemade MATLAB program. At 6 MV, the agreement between dose calculated by Monte Carlo modeling and direct measurement was obtained to the least restrictive of 1%, even in the build-up region. At 18 MV, the agreement was obtained 1%, except for in the build-up region. In the build-up region, the difference was 1% at 6 MV and 2% at 18 MV. The mean difference between measurements and Monte Carlo simulation is very small in both of ONCOR X-ray energy. The results are highly accurate and can be used for many applications such as patient dose calculation in treatment planning and in studies that model this linac with small field size like intensity-modulated radiation therapy technique.
Collapse
|
7
|
Schreiber EC, Sawkey DL, Faddegon BA. Sensitivity analysis of an asymmetric Monte Carlo beam model of a Siemens Primus accelerator. J Appl Clin Med Phys 2012; 13:3402. [PMID: 22402376 PMCID: PMC5716413 DOI: 10.1120/jacmp.v13i2.3402] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2010] [Revised: 09/30/2011] [Accepted: 10/31/2011] [Indexed: 11/29/2022] Open
Abstract
The assumption of cylindrical symmetry in radiotherapy accelerator models can pose a challenge for precise Monte Carlo modeling. This assumption makes it difficult to account for measured asymmetries in clinical dose distributions. We have performed a sensitivity study examining the effect of varying symmetric and asymmetric beam and geometric parameters of a Monte Carlo model for a Siemens PRIMUS accelerator. The accelerator and dose output were simulated using modified versions of BEAMnrc and DOSXYZnrc that allow lateral offsets of accelerator components and lateral and angular offsets for the incident electron beam. Dose distributions were studied for 40×40cm2 fields. The resulting dose distributions were analyzed for changes in flatness, symmetry, and off‐axis ratio (OAR). The electron beam parameters having the greatest effect on the resulting dose distributions were found to be electron energy and angle of incidence, as high as 5% for a 0.25° deflection. Electron spot size and lateral offset of the electron beam were found to have a smaller impact. Variations in photon target thickness were found to have a small effect. Small lateral offsets of the flattening filter caused significant variation to the OAR. In general, the greatest sensitivity to accelerator parameters could be observed for higher energies and off‐axis ratios closer to the central axis. Lateral and angular offsets of beam and accelerator components have strong effects on dose distributions, and should be included in any high‐accuracy beam model. PACS numbers: 87.55.K‐, 87.55.Gh
Collapse
Affiliation(s)
- Eric C Schreiber
- Department of Radiation Oncology, NCCH Rm. CB364, Campus Box 7512, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27514, USA.
| | | | | |
Collapse
|
8
|
Francescon P, Cora S, Satariano N. Calculation of kQclin,Qmsrfclin,fmsr for several small detectors and for two linear accelerators using Monte Carlo simulations. Med Phys 2011; 38:6513-27. [DOI: 10.1118/1.3660770] [Citation(s) in RCA: 134] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
9
|
Cho W, Kielar KN, Mok E, Xing L, Park JH, Jung WG, Suh TS. Multisource modeling of flattening filter free (FFF) beam and the optimization of model parameters. Med Phys 2011; 38:1931-42. [PMID: 21626926 PMCID: PMC3188653 DOI: 10.1118/1.3560426] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2010] [Revised: 02/06/2011] [Accepted: 02/07/2011] [Indexed: 11/07/2022] Open
Abstract
PURPOSE With the introduction of flattening filter free (FFF) linear accelerators to radiation oncology, new analytical source models for a FFF beam applicable to current treatment planning systems is needed. In this work, a multisource model for the FFF beam and the optimization of involved model parameters were designed. METHODS The model is based on a previous three source model proposed by Yang et al. ["A three-source model for the calculation of head scatter factors," Med. Phys. 29, 2024-2033 (2002)]. An off axis ratio (OAR) of photon fluence was introduced to the primary source term to generate cone shaped profiles. The parameters of the source model were determined from measured head scatter factors using a line search optimization technique. The OAR of the photon fluence was determined from a measured dose profile of a 40 x 40 cm2 field size with the same optimization technique, but a new method to acquire gradient terms for OARs was developed to enhance the speed of the optimization process. The improved model was validated with measured dose profiles from 3 x 3 to 40 x 40 cm2 field sizes at 6 and 10 MV from a TrueBeam STx linear accelerator. Furthermore, planar dose distributions for clinically used radiation fields were also calculated and compared to measurements using a 2D array detector using the gamma index method. RESULTS All dose values for the calculated profiles agreed with the measured dose profiles within 0.5% at 6 and 10 MV beams, except for some low dose regions for larger field sizes. A slight overestimation was seen in the lower penumbra region near the field edge for the large field sizes by 1%-4%. The planar dose calculations showed comparable passing rates (> 98%) when the criterion of the gamma index method was selected to be 3%/3 mm. CONCLUSIONS The developed source model showed good agreements between measured and calculated dose distributions. The model is easily applicable to any other linear accelerator using FFF beams as the required data include only the measured PDD, dose profiles, and output factors for various field sizes, which are easily acquired during conventional beam commissioning process.
Collapse
Affiliation(s)
- Woong Cho
- Department of Biomedical Engineering and Research Institute of Biomedical Engineering, College of Medicine, The Catholic University of Korea, Seoul 137-701, Korea
| | | | | | | | | | | | | |
Collapse
|
10
|
Chibani O, Moftah B, Ma CMC. On Monte Carlo modeling of megavoltage photon beams: a revisited study on the sensitivity of beam parameters. Med Phys 2011; 38:188-201. [PMID: 21361187 DOI: 10.1118/1.3523625] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE To commission Monte Carlo beam models for five Varian megavoltage photon beams (4, 6, 10, 15, and 18 MV). The goal is to closely match measured dose distributions in water for a wide range of field sizes (from 2 x 2 to 35 x 35 cm2). The second objective is to reinvestigate the sensitivity of the calculated dose distributions to variations in the primary electron beam parameters. METHODS The GEPTS Monte Carlo code is used for photon beam simulations and dose calculations. The linear accelerator geometric models are based on (i) manufacturer specifications, (ii) corrections made by Chibani and Ma ["On the discrepancies between Monte Carlo dose calculations and measurements for the 18 MV Varian photon beam," Med. Phys. 34, 1206-1216 (2007)], and (iii) more recent drawings. Measurements were performed using pinpoint and Farmer ionization chambers, depending on the field size. Phase space calculations for small fields were performed with and without angle-based photon splitting. In addition to the three commonly used primary electron beam parameters (E(AV) is the mean energy, FWHM is the energy spectrum broadening, and R is the beam radius), the angular divergence (theta) of primary electrons is also considered. RESULTS The calculated and measured dose distributions agreed to within 1% local difference at any depth beyond 1 cm for different energies and for field sizes varying from 2 x 2 to 35 x 35 cm2. In the penumbra regions, the distance to agreement is better than 0.5 mm, except for 15 MV (0.4-1 mm). The measured and calculated output factors agreed to within 1.2%. The 6, 10, and 18 MV beam models use theta = 0 degrees, while the 4 and 15 MV beam models require theta = 0.5 degrees and 0.6 degrees, respectively. The parameter sensitivity study shows that varying the beam parameters around the solution can lead to 5% differences with measurements for small (e.g., 2 x 2 cm2) and large (e.g., 35 x 35 cm2) fields, while a perfect agreement is maintained for the 10 x 10 cm2 field. The influence of R on the central-axis depth dose and the strong influence of theta on the lateral dose profiles are demonstrated. CONCLUSIONS Dose distributions for very small and very large fields were proved to be more sensitive to variations in E(AV), R, and theta in comparison with the 10 x 10 cm2 field. Monte Carlo beam models need to be validated for a wide range of field sizes including small field sizes (e.g., 2 x 2 cm2).
Collapse
Affiliation(s)
- Omar Chibani
- Department of Biomedical Physics, King Faisal Specialist Hospital and Research Center, Riyadh 11211, Kingdom of Saudi Arabia.
| | | | | |
Collapse
|
11
|
Sawkey D, Lu M, Morin O, Aubin M, Yom SS, Gottschalk AR, Bani-Hashemi A, Faddegon BA. A diamond target for megavoltage cone-beam CTa). Med Phys 2010; 37:1246-53. [DOI: 10.1118/1.3302831] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|