1
|
Mella H, Mura J, Wang H, Taylor MD, Chabiniok R, Tintera J, Sotelo J, Uribe S. HARP-I: A Harmonic Phase Interpolation Method for the Estimation of Motion From Tagged MR Images. IEEE TRANSACTIONS ON MEDICAL IMAGING 2021; 40:1240-1252. [PMID: 33434127 DOI: 10.1109/tmi.2021.3051092] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
We proposed a novel method called HARP-I, which enhances the estimation of motion from tagged Magnetic Resonance Imaging (MRI). The harmonic phase of the images is unwrapped and treated as noisy measurements of reference coordinates on a deformed domain, obtaining motion with high accuracy using Radial Basis Functions interpolations. Results were compared against Shortest Path HARP Refinement (SP-HR) and Sine-wave Modeling (SinMod), two harmonic image-based techniques for motion estimation from tagged images. HARP-I showed a favorable similarity with both methods under noise-free conditions, whereas a more robust performance was found in the presence of noise. Cardiac strain was better estimated using HARP-I at almost any motion level, giving strain maps with less artifacts. Additionally, HARP-I showed better temporal consistency as a new method was developed to fix phase jumps between frames. In conclusion, HARP-I showed to be a robust method for the estimation of motion and strain under ideal and non-ideal conditions.
Collapse
|
2
|
Strijkers GJ, Araujo EC, Azzabou N, Bendahan D, Blamire A, Burakiewicz J, Carlier PG, Damon B, Deligianni X, Froeling M, Heerschap A, Hollingsworth KG, Hooijmans MT, Karampinos DC, Loudos G, Madelin G, Marty B, Nagel AM, Nederveen AJ, Nelissen JL, Santini F, Scheidegger O, Schick F, Sinclair C, Sinkus R, de Sousa PL, Straub V, Walter G, Kan HE. Exploration of New Contrasts, Targets, and MR Imaging and Spectroscopy Techniques for Neuromuscular Disease - A Workshop Report of Working Group 3 of the Biomedicine and Molecular Biosciences COST Action BM1304 MYO-MRI. J Neuromuscul Dis 2020; 6:1-30. [PMID: 30714967 PMCID: PMC6398566 DOI: 10.3233/jnd-180333] [Citation(s) in RCA: 42] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Neuromuscular diseases are characterized by progressive muscle degeneration and muscle weakness resulting in functional disabilities. While each of these diseases is individually rare, they are common as a group, and a large majority lacks effective treatment with fully market approved drugs. Magnetic resonance imaging and spectroscopy techniques (MRI and MRS) are showing increasing promise as an outcome measure in clinical trials for these diseases. In 2013, the European Union funded the COST (co-operation in science and technology) action BM1304 called MYO-MRI (www.myo-mri.eu), with the overall aim to advance novel MRI and MRS techniques for both diagnosis and quantitative monitoring of neuromuscular diseases through sharing of expertise and data, joint development of protocols, opportunities for young researchers and creation of an online atlas of muscle MRI and MRS. In this report, the topics that were discussed in the framework of working group 3, which had the objective to: Explore new contrasts, new targets and new imaging techniques for NMD are described. The report is written by the scientists who attended the meetings and presented their data. An overview is given on the different contrasts that MRI can generate and their application, clinical needs and desired readouts, and emerging methods.
Collapse
Affiliation(s)
| | - Ericky C.A. Araujo
- NMR Laboratory, Neuromuscular Investigation Center, Institute of Myology & NMR Laboratory, CEA/DRF/IBFJ/MIRCen, Paris, France
| | - Noura Azzabou
- NMR Laboratory, Neuromuscular Investigation Center, Institute of Myology & NMR Laboratory, CEA/DRF/IBFJ/MIRCen, Paris, France
| | | | - Andrew Blamire
- Institute of Cellular Medicine, Newcastle University, Newcastle-upon-Tyne, UK
| | - Jedrek Burakiewicz
- Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands
| | - Pierre G. Carlier
- NMR Laboratory, Neuromuscular Investigation Center, Institute of Myology & NMR Laboratory, CEA/DRF/IBFJ/MIRCen, Paris, France
| | - Bruce Damon
- Vanderbilt University Medical Center, Nashville, USA
| | - Xeni Deligianni
- Department of Radiology, Division of Radiological Physics, University Hospital Basel, Basel, Switzerland & Department of Biomedical Engineering, University of Basel, Basel, Switzerland
| | | | - Arend Heerschap
- Radboud University Medical Center, Nijmegen, the Netherlands
| | | | | | | | | | | | - Benjamin Marty
- NMR Laboratory, Neuromuscular Investigation Center, Institute of Myology & NMR Laboratory, CEA/DRF/IBFJ/MIRCen, Paris, France
| | - Armin M. Nagel
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany & Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | | | | | - Francesco Santini
- Department of Radiology, Division of Radiological Physics, University Hospital Basel, Basel, Switzerland & Department of Biomedical Engineering, University of Basel, Basel, Switzerland
| | - Olivier Scheidegger
- Department of Neurology, Inselspital, Bern University Hospital, University of Bern, Switzerland
| | - Fritz Schick
- University of Tübingen, Section on Experimental Radiology, Tübingen, Germany
| | | | | | | | - Volker Straub
- Institute of Cellular Medicine, Newcastle University, Newcastle-upon-Tyne, UK
| | | | - Hermien E. Kan
- Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands
| |
Collapse
|
3
|
Mazzoli V, Gottwald LM, Peper ES, Froeling M, Coolen BF, Verdonschot N, Sprengers AM, Ooij P, Strijkers GJ, Nederveen AJ. Accelerated 4
D
phase contrast
MRI
in skeletal muscle contraction. Magn Reson Med 2018; 80:1799-1811. [DOI: 10.1002/mrm.27158] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2017] [Revised: 01/15/2018] [Accepted: 02/06/2018] [Indexed: 11/10/2022]
Affiliation(s)
- Valentina Mazzoli
- Department of RadiologyAcademic Medical CenterAmsterdam The Netherlands
- Biomedical NMR, Department of Biomedical EngineeringEindhoven University of TechnologyEindhoven The Netherlands
- Orthopaedic Research LabRadboud UMCNijmegen The Netherlands
| | - Lukas M. Gottwald
- Department of RadiologyAcademic Medical CenterAmsterdam The Netherlands
| | - Eva S. Peper
- Department of RadiologyAcademic Medical CenterAmsterdam The Netherlands
| | - Martijn Froeling
- Department of RadiologyUniversity Medical Center UtrechtUtrecht The Netherlands
| | - Bram F. Coolen
- Biomedical Engineering and PhysicsAcademic Medical CenterAmsterdam The Netherlands
| | - Nico Verdonschot
- Orthopaedic Research LabRadboud UMCNijmegen The Netherlands
- Laboratory for Biomechanical EngineeringUniversity of TwenteEnschede The Netherlands
| | - Andre M. Sprengers
- Orthopaedic Research LabRadboud UMCNijmegen The Netherlands
- Laboratory for Biomechanical EngineeringUniversity of TwenteEnschede The Netherlands
| | - Pim Ooij
- Department of RadiologyAcademic Medical CenterAmsterdam The Netherlands
| | - Gustav J. Strijkers
- Biomedical NMR, Department of Biomedical EngineeringEindhoven University of TechnologyEindhoven The Netherlands
- Biomedical Engineering and PhysicsAcademic Medical CenterAmsterdam The Netherlands
| | - Aart J. Nederveen
- Department of RadiologyAcademic Medical CenterAmsterdam The Netherlands
| |
Collapse
|
4
|
Lindsey ML, Kassiri Z, Virag JAI, de Castro Brás LE, Scherrer-Crosbie M. Guidelines for measuring cardiac physiology in mice. Am J Physiol Heart Circ Physiol 2018; 314:H733-H752. [PMID: 29351456 PMCID: PMC5966769 DOI: 10.1152/ajpheart.00339.2017] [Citation(s) in RCA: 226] [Impact Index Per Article: 37.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Cardiovascular disease is a leading cause of death, and translational research is needed to understand better mechanisms whereby the left ventricle responds to injury. Mouse models of heart disease have provided valuable insights into mechanisms that occur during cardiac aging and in response to a variety of pathologies. The assessment of cardiovascular physiological responses to injury or insult is an important and necessary component of this research. With increasing consideration for rigor and reproducibility, the goal of this guidelines review is to provide best-practice information regarding how to measure accurately cardiac physiology in animal models. In this article, we define guidelines for the measurement of cardiac physiology in mice, as the most commonly used animal model in cardiovascular research. Listen to this article’s corresponding podcast at http://ajpheart.podbean.com/e/guidelines-for-measuring-cardiac-physiology-in-mice/.
Collapse
Affiliation(s)
- Merry L Lindsey
- Department of Physiology and Biophysics, Mississippi Center for Heart Research, University of Mississippi Medical Center , Jackson, Mississippi.,Research Service, G.V. (Sonny) Montgomery Veterans Affairs Medical Center , Jackson, Mississippi
| | - Zamaneh Kassiri
- Department of Physiology, Cardiovascular Research Centre, Mazankowski Alberta Heart Institute, University of Alberta , Edmonton, Alberta , Canada
| | - Jitka A I Virag
- Department of Physiology, Brody School of Medicine, East Carolina University , Greenville, North Carolina
| | - Lisandra E de Castro Brás
- Department of Physiology, Brody School of Medicine, East Carolina University , Greenville, North Carolina
| | | |
Collapse
|
5
|
Sengeh DM, Moerman KM, Petron A, Herr H. Multi-material 3-D viscoelastic model of a transtibial residuum from in-vivo indentation and MRI data. J Mech Behav Biomed Mater 2016; 59:379-392. [DOI: 10.1016/j.jmbbm.2016.02.020] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2015] [Revised: 02/11/2016] [Accepted: 02/12/2016] [Indexed: 11/28/2022]
|
6
|
Silva MET, Brandão S, Parente MPL, Mascarenhas T, Natal Jorge RM. Establishing the biomechanical properties of the pelvic soft tissues through an inverse finite element analysis using magnetic resonance imaging. Proc Inst Mech Eng H 2016; 230:298-309. [DOI: 10.1177/0954411916630571] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2015] [Accepted: 01/12/2016] [Indexed: 12/16/2022]
Abstract
The mechanical characteristics of the female pelvic floor are relevant when explaining pelvic dysfunction. The decreased elasticity of the tissue often causes inability to maintain urethral position, also leading to vaginal and rectal descend when coughing or defecating as a response to an increase in the internal abdominal pressure. These conditions can be associated with changes in the mechanical properties of the supportive structures—namely, the pelvic floor muscles—including impairment. In this work, we used an inverse finite element analysis to calculate the material constants for the passive mechanical behavior of the pelvic floor muscles. The numerical model of the pelvic floor muscles and bones was built from magnetic resonance axial images acquired at rest. Muscle deformation, simulating the Valsalva maneuver with a pressure of 4 KPa, was compared with the muscle displacement obtained through additional dynamic magnetic resonance imaging. The difference in displacement was of 0.15 mm in the antero-posterior direction and 3.69 mm in the supero-inferior direction, equating to a percentage error of 7.0% and 16.9%, respectively. We obtained the shortest difference in the displacements using an iterative process that reached the material constants for the Mooney–Rivlin constitutive model ( c10=11.8 KPa and c20=5.53 E−02 KPa). For each iteration, the orthogonal distance between each node from the group of nodes which defined the puborectal muscle in the numerical model versus dynamic magnetic resonance imaging was computed. With the methodology used in this work, it was possible to obtain in vivo biomechanical properties of the pelvic floor muscles for a specific subject using input information acquired non-invasively.
Collapse
Affiliation(s)
- MET Silva
- LAETA-INEGI, Faculty of Engineering, University of Porto, Porto, Portugal
| | - S Brandão
- LAETA-INEGI, Faculty of Engineering, University of Porto, Porto, Portugal
- Department of Radiology, Centro Hospitalar de São João—EPE, Faculty of Medicine, University of Porto, Porto, Portugal
| | - MPL Parente
- LAETA-INEGI, Faculty of Engineering, University of Porto, Porto, Portugal
| | - T Mascarenhas
- Department of Gynecology and Obstetrics, Centro Hospitalar de São João—EPE, Faculty of Medicine, University of Porto, Porto, Portugal
| | - RM Natal Jorge
- LAETA-INEGI, Faculty of Engineering, University of Porto, Porto, Portugal
| |
Collapse
|
7
|
Estimation of musculotendon kinematics under controlled tendon indentation. J Biomech 2015; 48:3568-76. [PMID: 26321363 DOI: 10.1016/j.jbiomech.2015.07.024] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2014] [Revised: 06/21/2015] [Accepted: 07/21/2015] [Indexed: 11/24/2022]
Abstract
The effects of tendon indentation on musculotendon unit mechanics have been left largely unexplored. Tendon indentation is however routinely used in the tendon reflex exam to diagnose the state of reflex pathways. Because muscle mechanoreceptors are sensitive to mechanical changes of the musculotendon unit, this gap in knowledge could potentially impact our understanding of these neurological exams. Accordingly, we have used ultrasound (US) imaging to compare the effects of tendon indentation with the effects angular rotation of the elbow in six neurologically intact individuals. We used sagittal ultrasound movies of the biceps brachii to compare length changes induced by each of these perturbations. Length changes were quantified using a pixel-tracking protocol. Our results show that a 20mm indentation of the distal tendon is broadly equivalent to a 15° elbow rotation. We also show that within the imaging window the strain differences between the two stretching protocols are statistically insignificant. Finally, we show that there exists a significant linear relationship between the two stretching techniques and that this relationship spans a large rotational angle to indentation depth. We have used a novel tendon probe to administer controlled tendon indentations as a way to characterize musculotendon kinematics. Using this probe, we confirm that tendon indentation can be physiologically equated with joint rotation, and can thus be used as an input for muscle stretching protocols. Furthermore, this is potentially a simpler and more practical alternative to externally imposed angular joint motion.
Collapse
|
8
|
Measurement of the quadriceps muscle displacement and strain fields with ultrasound and Digital Image Correlation (DIC) techniques. Ing Rech Biomed 2015. [DOI: 10.1016/j.irbm.2015.02.002] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
9
|
Sampath S, Klimas M, Feng D, Baumgartner R, Manigbas E, Liang AL, Evelhoch JL, Chin CL. Characterization of regional left ventricular function in nonhuman primates using magnetic resonance imaging biomarkers: a test-retest repeatability and inter-subject variability study. PLoS One 2015; 10:e0127947. [PMID: 26010607 PMCID: PMC4444127 DOI: 10.1371/journal.pone.0127947] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2015] [Accepted: 04/20/2015] [Indexed: 12/22/2022] Open
Abstract
Pre-clinical animal models are important to study the fundamental biological and functional mechanisms involved in the longitudinal evolution of heart failure (HF). Particularly, large animal models, like nonhuman primates (NHPs), that possess greater physiological, biochemical, and phylogenetic similarity to humans are gaining interest. To assess the translatability of these models into human diseases, imaging biomarkers play a significant role in non-invasive phenotyping, prediction of downstream remodeling, and evaluation of novel experimental therapeutics. This paper sheds insight into NHP cardiac function through the quantification of magnetic resonance (MR) imaging biomarkers that comprehensively characterize the spatiotemporal dynamics of left ventricular (LV) systolic pumping and LV diastolic relaxation. MR tagging and phase contrast (PC) imaging were used to quantify NHP cardiac strain and flow. Temporal inter-relationships between rotational mechanics, myocardial strain and LV chamber flow are presented, and functional biomarkers are evaluated through test-retest repeatability and inter subject variability analyses. The temporal trends observed in strain and flow was similar to published data in humans. Our results indicate a dominant dimension based pumping during early systole, followed by a torsion dominant pumping action during late systole. Early diastole is characterized by close to 65% of untwist, the remainder of which likely contributes to efficient filling during atrial kick. Our data reveal that moderate to good intra-subject repeatability was observed for peak strain, strain-rates, E/circumferential strain-rate (CSR) ratio, E/longitudinal strain-rate (LSR) ratio, and deceleration time. The inter-subject variability was high for strain dyssynchrony, diastolic strain-rates, peak torsion and peak untwist rate. We have successfully characterized cardiac function in NHPs using MR imaging. Peak strain, average systolic strain-rate, diastolic E/CSR and E/LSR ratios, and deceleration time were identified as robust biomarkers that could potentially be applied to future pre-clinical drug studies.
Collapse
Affiliation(s)
- Smita Sampath
- Imaging, Merck Research Laboratories, Merck Sharp & Dohme, Singapore, Singapore
- * E-mail:
| | - Michael Klimas
- Imaging, Merck Research Laboratories, Merck & Co. Inc., West Point, Pennsylvania, United States of America
| | - Dai Feng
- Biometric Research, Merck Research Laboratories, Biostatistics and Research Decision Sciences, Merck & Co. Inc., Rahway, New Jersey, United States of America
| | - Richard Baumgartner
- Biometric Research, Merck Research Laboratories, Biostatistics and Research Decision Sciences, Merck & Co. Inc., Rahway, New Jersey, United States of America
| | | | - Ai-Leng Liang
- Imaging, Merck Research Laboratories, Merck Sharp & Dohme, Singapore, Singapore
| | - Jeffrey L. Evelhoch
- Imaging, Merck Research Laboratories, Merck & Co. Inc., West Point, Pennsylvania, United States of America
| | - Chih-Liang Chin
- Imaging, Merck Research Laboratories, Merck Sharp & Dohme, Singapore, Singapore
| |
Collapse
|
10
|
Sprengers AMJ, Caan MWA, Moerman KM, Nederveen AJ, Lamerichs RM, Stoker J. A scale space based algorithm for automated segmentation of single shot tagged MRI of shearing deformation. MAGMA (NEW YORK, N.Y.) 2013; 26:229-238. [PMID: 22892993 DOI: 10.1007/s10334-012-0332-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/18/2012] [Revised: 06/21/2012] [Accepted: 07/19/2012] [Indexed: 06/01/2023]
Abstract
OBJECT This study proposes a scale space based algorithm for automated segmentation of single-shot tagged images of modest SNR. Furthermore the algorithm was designed for analysis of discontinuous or shearing types of motion, i.e. segmentation of broken tag patterns. MATERIALS AND METHODS The proposed algorithm utilises non-linear scale space for automatic segmentation of single-shot tagged images. The algorithm's ability to automatically segment tagged shearing motion was evaluated in a numerical simulation and in vivo. A typical shearing deformation was simulated in a Shepp-Logan phantom allowing for quantitative evaluation of the algorithm's success rate as a function of both SNR and the amount of deformation. For a qualitative in vivo evaluation tagged images showing deformations in the calf muscles and eye movement in a healthy volunteer were acquired. RESULTS Both the numerical simulation and the in vivo tagged data demonstrated the algorithm's ability for automated segmentation of single-shot tagged MR provided that SNR of the images is above 10 and the amount of deformation does not exceed the tag spacing. The latter constraint can be met by adjusting the tag delay or the tag spacing. CONCLUSION The scale space based algorithm for automatic segmentation of single-shot tagged MR enables the application of tagged MR to complex (shearing) deformation and the processing of datasets with relatively low SNR.
Collapse
Affiliation(s)
- Andre M J Sprengers
- Department of Radiology, Academic Medical Center, University of Amsterdam, Meibergdreef 9, 1105 AZ, Amsterdam, The Netherlands.
| | | | | | | | | | | |
Collapse
|
11
|
Moerman KM, Sprengers AMJ, Nederveen AJ, Simms CK. A novel MRI compatible soft tissue indentor and fibre Bragg grating force sensor. Med Eng Phys 2012; 35:486-99. [PMID: 22819569 DOI: 10.1016/j.medengphy.2012.06.014] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2011] [Revised: 05/02/2012] [Accepted: 06/20/2012] [Indexed: 11/26/2022]
Abstract
MRI is an ideal method for non-invasive soft tissue mechanical properties investigation. This requires mechanical excitation of the body's tissues and measurement of the corresponding boundary conditions such as soft tissue deformation inside the MRI environment. However, this is technically difficult since load application and measurement of boundary conditions requires MRI compatible actuators and sensors. This paper describes a novel MRI compatible computer controlled soft tissue indentor and optical Fibre Bragg Grating (FBG) force sensor. The high acquisition rate (100Hz) force sensor was calibrated for forces up to 15N and demonstrated a maximum error of 0.043N. Performance and MRI compatibility of the devices was verified using indentation tests on a silicone gel phantom and the upper arm of a volunteer. The computer controlled indentor provided a highly repeatable tissue deformation. Since the indentor and force sensor are composed of non-ferromagnetic materials, they are MRI compatible and no artefacts or temporal SNR reductions were observed. In a phantom study the mean and standard deviation of the temporal SNR levels without the indentor present were 500.18 and 207.08, respectively. With the indentor present the mean and standard deviation were 501.95 and 200.45, respectively. This computer controlled MRI compatible soft tissue indentation system with an integrated force sensor has a broad range of applications and will be used in the future for the non-invasive analysis of the mechanical properties of skeletal muscle tissue.
Collapse
Affiliation(s)
- Kevin M Moerman
- Trinity Centre for Bioengineering, School of Engineering, Parsons Building, Trinity College, Dublin 2, Ireland.
| | | | | | | |
Collapse
|
12
|
Moerman KM, Sprengers AMJ, Simms CK, Lamerichs RM, Stoker J, Nederveen AJ. Validation of continuously tagged MRI for the measurement of dynamic 3D skeletal muscle tissue deformation. Med Phys 2012; 39:1793-810. [PMID: 22482602 DOI: 10.1118/1.3685579] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE Typically spatial modulation of the magnetization (SPAMM) tagged magnetic resonance imaging (MRI) requires many repeated motion cycles limiting the applicability to highly repeatable tissue motions only. This paper describes the validation of a novel SPAMM tagged MRI and post-processing framework for the measurement of complex and dynamic 3D soft tissue deformation following just three motion cycles. Techniques are applied to indentation induced deformation measurement of the upper arm and a silicone gel phantom. METHODS A SPAMM tagged MRI methodology is presented allowing continuous (3.3-3.6 Hz) sampling of 3D dynamic soft tissue deformation using non segmented 3D acquisitions. The 3D deformation is reconstructed by the combination of three mutually orthogonal tagging directions, thus requiring only three repeated motion cycles. In addition a fully automatic post-processing framework is presented employing Gabor scale-space and filter-bank analysis for tag extrema segmentation and triangulated surface fitting aided by Gabor filter bank derived surface normals. Deformation is derived following tracking of tag surface triplet triangle intersections. The dynamic deformation measurements were validated using indentation tests (∼20 mm deep at 12 mm/s) on a silicone gel soft tissue phantom containing contrasting markers which provide a reference measure of deformation. In addition, the techniques were evaluated in vivo for dynamic skeletal muscle tissue deformation measurement during indentation of the biceps region of the upper arm in a volunteer. RESULTS For the phantom and volunteer tag point location precision were 44 and 92 μm, respectively resulting in individual displacements precisions of 61 and 91 μm, respectively. For both the phantom and volunteer data cumulative displacement measurement accuracy could be evaluated and the difference between initial and final locations showed a mean and standard deviation of 0.44 and 0.59 mm for the phantom and 0.40 and 0.73 mm for the human data. Finally accuracy of (cumulative) displacement was evaluated using marker tracking in the silicone gel phantom. Differences between true and predicted marker locations showed a mean of 0.35 mm and a standard deviation of 0.63 mm. CONCLUSIONS A novel SPAMM tagged MRI and fully automatic post-processing framework for the measurement of complex 3D dynamic soft tissue deformation following just three repeated motion cycles was presented. The techniques demonstrate dynamic measurement of complex 3D soft tissue deformation at subvoxel accuracy and precision and were validated for 3.3-3.6 Hz sampling of deformation speeds up to 12 mm/s.
Collapse
Affiliation(s)
- Kevin M Moerman
- Radiology Department, Academic Medical Centre, Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands.
| | | | | | | | | | | |
Collapse
|