Dong Y, Yang F, Wen J, Cai J, Zeng F, Liu M, Li S, Wang J, Ford JC, Portelance L, Yang Y. Improvement of 2D cine image quality using 3D priors and cycle generative adversarial network for low field MRI-guided radiation therapy. Med Phys 2024; 51:3495-3509. [PMID: 38043123 DOI: 10.1002/mp.16860] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2023] [Revised: 10/12/2023] [Accepted: 11/05/2023] [Indexed: 12/05/2023] Open
Abstract
BACKGROUND Cine magnetic resonance (MR) images have been used for real-time MR guided radiation therapy (MRgRT). However, the onboard MR systems with low-field strength face the problem of limited image quality. PURPOSE To improve the quality of cine MR images in MRgRT using prior image information provided by the patient planning and positioning MR images. METHODS This study employed MR images from 18 pancreatic cancer patients who received MR-guided stereotactic body radiation therapy. Planning 3D MR images were acquired during the patient simulation, and positioning 3D MR images and 2D sagittal cine MR images were acquired before and during the beam delivery, respectively. A deep learning-based framework consisting of two cycle generative adversarial networks (CycleGAN), Denoising CycleGAN and Enhancement CycleGAN, was developed to establish the mapping between the 3D and 2D MR images. The Denoising CycleGAN was trained to first denoise the cine images using the time domain cine image series, and the Enhancement CycleGAN was trained to enhance the spatial resolution and contrast by taking advantage of the prior image information from the planning and positioning images. The denoising performance was assessed by signal-to-noise ratio (SNR), structural similarity index measure, peak SNR, blind/reference-less image spatial quality evaluator (BRISQUE), natural image quality evaluator, and perception-based image quality evaluator scores. The quality enhancement performance was assessed by the BRISQUE and physician visual scores. In addition, the target contouring was evaluated on the original and processed images. RESULTS Significant differences were found for all evaluation metrics after Denoising CycleGAN processing. The BRISQUE and visual scores were also significantly improved after sequential Denoising and Enhancement CycleGAN processing. In target contouring evaluation, Dice similarity coefficient, centroid distance, Hausdorff distance, and average surface distance values were significantly improved on the enhanced images. The whole processing time was within 20 ms for a typical input image size of 512 × 512. CONCLUSION Taking advantage of the prior high-quality positioning and planning MR images, the deep learning-based framework enhanced the cine MR image quality significantly, leading to improved accuracy in automatic target contouring. With the merits of both high computational efficiency and considerable image quality enhancement, the proposed method may hold important clinical implication for real-time MRgRT.
Collapse
Affiliation(s)
- Yuyan Dong
- Department of Engineering and Applied Physics, University of Science and Technology of China, Hefei, Anhui, China
| | - Fei Yang
- The Miller School of Medicine, University of Miami, Miami, Florida, USA
| | - Jie Wen
- Department of Radiology, the First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui, China
| | - Jing Cai
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Kowloon, Hong Kong, China
| | - Feiyan Zeng
- Department of Radiology, the First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui, China
| | - Mengqiu Liu
- Department of Radiology, the First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui, China
| | - Shuang Li
- Department of Radiology, the First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui, China
| | - Jiangtao Wang
- Cancer Center, Sichuan Academy of Medical Sciences Sichuan Provincial People's Hospital, Chengdu, Sichuan, China
| | - John Chetley Ford
- The Miller School of Medicine, University of Miami, Miami, Florida, USA
| | | | - Yidong Yang
- Department of Engineering and Applied Physics, University of Science and Technology of China, Hefei, Anhui, China
- Department of Radiation Oncology, the First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui, China
| |
Collapse
|
2
|
Wu A, Cui H, Jiang X, Yan B, Wu A, Liu Y, Zhu L. Development and validation of a scatter-corrected CBCT image-guided method for cervical cancer brachytherapy. Front Oncol 2022; 12:942016. [DOI: 10.3389/fonc.2022.942016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2022] [Accepted: 10/10/2022] [Indexed: 11/13/2022] Open
Abstract
Background and purposeMultiple patient transfers have a nonnegligible impact on the accuracy of dose delivery for cervical cancer brachytherapy. We consider using on-site cone-beam CT (CBCT) to resolve this problem. However, CBCT clinical applications are limited due to inadequate image quality. This paper implements a scatter correction method using planning CT (pCT) prior to obtaining high-quality CBCT images and evaluates the dose calculation accuracy of CBCT-guided brachytherapy for cervical cancer.Materials and methodsThe CBCT of a self-developed female pelvis phantom and five patients was first corrected using empirical uniform scatter correction in the projection domain and further corrected in the image domain. In both phantom and patient studies, the CBCT image quality before and after scatter correction was evaluated with registered pCT (rCT). Model-based dose calculation was performed using the commercial package Acuros®BV. The dose distributions of rCT-based plans and corrected CBCT-based plans in the phantom and patients were compared using 3D local gamma analysis. A statistical analysis of the differences in dosimetric parameters of five patients was also performed.ResultsIn both phantom and patient studies, the HU error of selected ROIs was reduced to less than 15 HU. Using the dose distribution of the rCT-based plan as the baseline, the γ pass rate (2%, 2 mm) of the corrected CBCT-based plan in phantom and patients all exceeded 98% and 93%, respectively, with the threshold dose set to 3, 6, 9, and 12 Gy. The average percentage deviation (APD) of D90 of HRCTV and D2cc of OARs was less than 1% between rCT-based and corrected CBCT-based plans.ConclusionScatter correction using a pCT prior can effectively improve the CBCT image quality and CBCT-based cervical brachytherapy dose calculation accuracy, indicating promising prospects in both simplified brachytherapy processes and accurate brachytherapy dose delivery.
Collapse
|