Al-Hayek Y, Zheng X, Hayre C, Spuur K. The influence of patient positioning on radiation dose in CT imaging: A narrative review. J Med Imaging Radiat Sci 2022; 53:737-747. [PMID: 36280573 DOI: 10.1016/j.jmir.2022.09.027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2022] [Revised: 09/21/2022] [Accepted: 09/29/2022] [Indexed: 11/29/2022]
Abstract
BACKGROUND AND PURPOSE Although it is fundamental for optimal scanner operation, it is generally accepted that accurate patient centring cannot always be achieved. This review aimed to examine the reported knowledge of the negative impact of patient positioning on radiation dose and image quality during CT imaging. Furthermore, the study evaluated the current optimisation tools and techniques used to improve patient positioning relative to the gantry iso-center. METHODOLOGY A comprehensive search through the databases PubMed, Ovid, and Google Scholar was performed. Keywords included patient off-centring, patient positioning, localiser radiograph orientation, radiation dose, and automatic patient positioning (including synonyms). The search was limited to full-text articles that were written in English. After initial title and abstract screening, a total of 52 articles were identified to address the aim of the review. No limitations were imposed on the year of publication. RESULTS Vertical off-centring was reported in up to 95% of patients undergoing chest and abdominal CT examinations, showing a significant influence on radiation dose. Depending on the scanner model and vendor, localiser orientation, bowtie filter used, and patient size, radiation dose varied from a decrease of 36% to an increase of 91%. A significant dose reduction was demonstrated when utilising an AP localiser, aligning with the trend for radiographers to off-center patients below the gantry iso-centre. Utilizing a 3D camera for body contour detection allowed for more accurate patient positioning and promoted further dose reduction. CONCLUSION Patient positioning has shown significant effects on radiation dose and image quality in CT. Developing a good understanding of the key factors influencing patient dose (off-centring direction, localiser orientation, patient size and bowtie filter selection) is critical in optimising CT scanning practices. Utilising a 3D camera for body contour detection is strongly recommended to improve patient positioning accuracy, image quality and to minimise patient dose.
Collapse
Affiliation(s)
- Yazan Al-Hayek
- School of Dentistry and Medical Sciences, Faculty of Science and Health, Charles Sturt University, Wagga Wagga, NSW, 2650, Australia; Department of Medical Imaging, Faculty of Applied Health Sciences, The Hashemite University, Zarqa, 13133, Jordan.
| | - Xiaoming Zheng
- School of Dentistry and Medical Sciences, Faculty of Science and Health, Charles Sturt University, Wagga Wagga, NSW, 2650, Australia.
| | - Christopher Hayre
- Department of Medical Imaging, College of Medicine and Health, University of Exeter, Devon, UK.
| | - Kelly Spuur
- School of Dentistry and Medical Sciences, Faculty of Science and Health, Charles Sturt University, Wagga Wagga, NSW, 2650, Australia.
| |
Collapse
|
2
|
Patient positioning during pediatric cardiothoracic computed tomography using a high-resilience pad system and pre-scan measurement of chest thickness. Sci Rep 2022; 12:16618. [PMID: 36198731 PMCID: PMC9534888 DOI: 10.1038/s41598-022-21018-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2022] [Accepted: 09/21/2022] [Indexed: 11/09/2022] Open
Abstract
Patient positioning at the isocenter of the CT gantry is important for optimizing image quality and radiation dose, but accurate positioning is challenging in pediatric patients. We evaluated whether the high-resilience pad and pre-scan measurement of chest thickness allow accurate positioning in pediatric patients with congenital heart disease. Sixty-seven patients aged 7 years or younger who underwent cardiothoracic CT were enrolled. The ideal table height, defined as the position at which the scanner’s and patient’s isocenters coincided, was determined by radiographers either manually (manual group) or based on the pad’s and chest’s thickness (calculated group). The distance between the two isocenters and image quality were evaluated. The calculated group demonstrated smaller isocenter distance and standard deviation (distance: 0.2 ± 5.8 mm vs. − 8.3 ± 11.6 mm, p < 0.01; absolute value: 4.1 [1.9–8.0] mm vs. 12.3 [5.1–16.3] mm, p < 0.01), and higher signal-to-noise ratio (SNR) and dose-normalized SNR (SNRD) in the descending aorta than the manual group (SNR: 39.8 [31.0–53.7] vs. 31.9 [28.9–36.6], p = 0.048, SNRD: 39.8 [31.0–53.7] vs. 31.9 [28.9–36.6], p = 0.04). The system allowed for more accurate positioning in pediatric cardiothoracic CT, yielding higher image quality.
Collapse
|
3
|
Irdawati Y, Sutanto H, Anam C, Fujibuchi T, Zahroh F, Dougherty G. Development of a novel artifact-free eye shield based on silicon rubber-lead composition in the CT examination of the head. JOURNAL OF RADIOLOGICAL PROTECTION : OFFICIAL JOURNAL OF THE SOCIETY FOR RADIOLOGICAL PROTECTION 2019; 39:991-1005. [PMID: 31272094 DOI: 10.1088/1361-6498/ab2f3e] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
The aim of this work was to develop a novel artifact-free eye shield and evaluate its effect on the dose received by the eye lens and the resulting image quality in the CT examination of the head. A new material for an eye shield was synthesised from silicon rubber (SR) and lead (Pb) using a simple method. The percentage of Pb was varied from 0 to 5% wt. An anthropomorphic head phantom was scanned with and without the SR-Pb eye shield, and compared with a tungsten paper (WP) eye shield. The distance from the eye shield and head was varied from 0 to 5 cm. The dose to the eye lens was measured using photo-luminescence detectors (PLDs). The presence of artifacts was determined by measuring CT numbers at different eye lens locations and by subtracting images with and without the eye shield. The dose reduction increases with increasing Pb content in the SR-Pb eye shield. A 5% wt SR-Pb eye shield reduced the eye lens dose by up to 50%, whereas the WP eye shield reduced the dose by up to 86%. The CT numbers in images with the SR-Pb eye shield in the regions of both eyes and the center of the head phantom is similar to those without the eye shield, indicating that there is no artifact in the resulting image. Using the WP eye shield, there is considerable artifact with the CT number increasing by up to 700% in the regions of both eyes and the center of the head. It is found that the distance between the SR-Pb eye shield and the head does not affect either the dose or the resulting images. A SR-Pb-based eye shield can be applied in clinical environments and should be placed directly above the eye surface for dose optimisation.
Collapse
Affiliation(s)
- Yulia Irdawati
- Department of Physics, Faculty of Sciences and Mathematics, Diponegoro University, Jl. Prof. Soedarto SH, Tembalang, Semarang 50275, Central Java, Indonesia
| | | | | | | | | | | |
Collapse
|
4
|
Booij R, Budde RPJ, Dijkshoorn ML, van Straten M. Accuracy of automated patient positioning in CT using a 3D camera for body contour detection. Eur Radiol 2018; 29:2079-2088. [PMID: 30306328 PMCID: PMC6420476 DOI: 10.1007/s00330-018-5745-z] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2018] [Revised: 08/14/2018] [Accepted: 09/10/2018] [Indexed: 12/31/2022]
Abstract
Objective To assess the accuracy of a 3D camera for body contour detection and patient positioning in CT compared to routine manual positioning by radiographers. Methods and materials Four hundred twenty-three patients that underwent CT of the head, thorax, and/or abdomen on a scanner with manual table height selection and 254 patients on a scanner with table height suggestion by a 3D camera were retrospectively included. Within the camera group, table height suggestion was based on infrared body contour detection and fitting of a scalable patient model to the 3D data. Proper positioning was defined as the ideal table height at which the scanner isocenter coincides with the patient’s isocenter. Patient isocenter was computed by automatic skin contour extraction in each axial image and averaged over all images. Table heights suggested by the camera and selected by the radiographer were compared with the ideal height. Results Median (interquartile range) absolute table height deviation in millimeter was 12.0 (21.6) for abdomen, 12.2 (12.0) for head, 13.4 (17.6) for thorax-abdomen, and 14.7 (17.3) for thorax CT scans positioned by radiographers. The deviation was significantly less (p < 0.01) for the 3D camera at 6.3 (6.9) for abdomen, 9.5 (6.8) for head, 6.0 (6.1) for thorax-abdomen, and 5.4 (6.4) mm for thorax. Conclusion A 3D camera for body contour detection allows for accurate patient positioning, thereby outperforming manual positioning done by radiographers, resulting in significantly smaller deviations from the ideal table height. However, radiographers remain indispensable when the system fails or in challenging cases. Key Points • A 3D camera for body contour detection allows for accurate patient positioning. • A 3D camera outperformed radiographers in patient positioning in CT. • Deviation from ideal table height was more extreme for patients positioned by radiographers for all body parts.
Collapse
Affiliation(s)
- Ronald Booij
- Department of Radiology and Nuclear Medicine, Erasmus Medical Center, P.O. Box 2240, 3000 CA, Rotterdam, The Netherlands.
| | - Ricardo P J Budde
- Department of Radiology and Nuclear Medicine, Erasmus Medical Center, P.O. Box 2240, 3000 CA, Rotterdam, The Netherlands
| | - Marcel L Dijkshoorn
- Department of Radiology and Nuclear Medicine, Erasmus Medical Center, P.O. Box 2240, 3000 CA, Rotterdam, The Netherlands
| | - Marcel van Straten
- Department of Radiology and Nuclear Medicine, Erasmus Medical Center, P.O. Box 2240, 3000 CA, Rotterdam, The Netherlands
| |
Collapse
|
5
|
Gomez-Cardona D, Cruz-Bastida JP, Li K, Budde A, Hsieh J, Chen GH. Impact of bowtie filter and object position on the two-dimensional noise power spectrum of a clinical MDCT system. Med Phys 2016; 43:4495. [PMID: 27487866 DOI: 10.1118/1.4954848] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023] Open
Abstract
PURPOSE Noise characteristics of clinical multidetector CT (MDCT) systems can be quantified by the noise power spectrum (NPS). Although the NPS of CT has been extensively studied in the past few decades, the joint impact of the bowtie filter and object position on the NPS has not been systematically investigated. This work studies the interplay of these two factors on the two dimensional (2D) local NPS of a clinical CT system that uses the filtered backprojection algorithm for image reconstruction. METHODS A generalized NPS model was developed to account for the impact of the bowtie filter and image object location in the scan field-of-view (SFOV). For a given bowtie filter, image object, and its location in the SFOV, the shape and rotational symmetries of the 2D local NPS were directly computed from the NPS model without going through the image reconstruction process. The obtained NPS was then compared with the measured NPSs from the reconstructed noise-only CT images in both numerical phantom simulation studies and experimental phantom studies using a clinical MDCT scanner. The shape and the associated symmetry of the 2D NPS were classified by borrowing the well-known atomic spectral symbols s, p, and d, which correspond to circular, dumbbell, and cloverleaf symmetries, respectively, of the wave function of electrons in an atom. Finally, simulated bar patterns were embedded into experimentally acquired noise backgrounds to demonstrate the impact of different NPS symmetries on the visual perception of the object. RESULTS (1) For a central region in a centered cylindrical object, an s-wave symmetry was always present in the NPS, no matter whether the bowtie filter was present or not. In contrast, for a peripheral region in a centered object, the symmetry of its NPS was highly dependent on the bowtie filter, and both p-wave symmetry and d-wave symmetry were observed in the NPS. (2) For a centered region-ofinterest (ROI) in an off-centered object, the symmetry of its NPS was found to be different from that of a peripheral ROI in the centered object, even when the physical positions of the two ROIs relative to the isocenter were the same. (3) The potential clinical impact of the highly anisotropic NPS, caused by the interplay of the bowtie filter and position of the image object, was highlighted in images of specific bar patterns oriented at different angles. The visual perception of the bar patterns was found to be strongly dependent on their orientation. CONCLUSIONS The NPS of CT depends strongly on the bowtie filter and object position. Even if the location of the ROI with respect to the isocenter is fixed, there can be different symmetries in the NPS, which depend on the object position and the size of the bowtie filter. For an isolated off-centered object, the NPS of its CT images cannot be represented by the NPS measured from a centered object.
Collapse
Affiliation(s)
- Daniel Gomez-Cardona
- Department of Medical Physics, University of Wisconsin-Madison School of Medicine and Public Health, 1111 Highland Avenue, Madison, Wisconsin 53705
| | - Juan Pablo Cruz-Bastida
- Department of Medical Physics, University of Wisconsin-Madison School of Medicine and Public Health, 1111 Highland Avenue, Madison, Wisconsin 53705
| | - Ke Li
- Department of Medical Physics, University of Wisconsin-Madison School of Medicine and Public Health, 1111 Highland Avenue, Madison, Wisconsin 53705 and Department of Radiology, University of Wisconsin-Madison School of Medicine and Public Health, 600 Highland Avenue, Madison, Wisconsin 53792
| | - Adam Budde
- Department of Medical Physics, University of Wisconsin-Madison School of Medicine and Public Health, 1111 Highland Avenue, Madison, Wisconsin 53705 and GE Healthcare, 3000 N Grandview Boulevard, Waukesha, Wisconsin 53188
| | - Jiang Hsieh
- Department of Medical Physics, University of Wisconsin-Madison School of Medicine and Public Health, 1111 Highland Avenue, Madison, Wisconsin 53705 and GE Healthcare, 3000 N Grandview Boulevard, Waukesha, Wisconsin 53188
| | - Guang-Hong Chen
- Department of Medical Physics, University of Wisconsin-Madison School of Medicine and Public Health, 1111 Highland Avenue, Madison, Wisconsin 53705 and Department of Radiology, University of Wisconsin-Madison School of Medicine and Public Health, 600 Highland Avenue, Madison, Wisconsin 53792
| |
Collapse
|
6
|
Vañó E, Miller DL, Dauer L. Implications in medical imaging of the new ICRP thresholds for tissue reactions. Ann ICRP 2015; 44:118-128. [PMID: 25816265 DOI: 10.1177/0146645314562322] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
The International Commission on Radiological Protection (ICRP) statement on tissue reactions, issued by the Commission in April 2011, reviewed epidemiological evidence and suggested that there are some tissue reactions where threshold doses are or may be lower than those previously considered. For the lens of the eye, the threshold is now considered to be 0.5 Gy. The absorbed dose threshold for circulatory disease in the heart and brain may be as low as 0.5 Gy. These values can be reached in some patients during interventional cardiology or neuroradiology procedures. They may also be of concern for repeated computed tomography examinations of the head. The new thresholds should be considered in optimisation strategies for clinical procedures, especially in patients likely to require repeated interventions. The new dose thresholds also affect occupational protection for operators and staff. Some operators do not protect their eyes or their brain adequately. After several years of work without proper protection, the absorbed doses to the lens of the eye and the brain of staff can exceed 0.5 Gy. More research is needed to understand the biological effects of cumulative incident air kerma and the instantaneous air kerma rates currently used in medical imaging. The new thresholds, and the need for specific occupational dosimetry related to lens doses, should be considered in radiation protection programmes, and should be included in the education and training of professionals involved in fluoroscopy guided procedures and computed tomography.
Collapse
Affiliation(s)
- E Vañó
- Radiology Department, Medicine School and San Carlos Hospital, Complutense University, Madrid, 28040 Spain
| | - D L Miller
- Center for Devices and Radiological Health, Food and Drug Administration, USA
| | - L Dauer
- Department of Medical Physics, Department of Radiology. Memorial Sloan-Kettering Cancer Center, USA
| |
Collapse
|
7
|
Lens dose in routine head CT: comparison of different optimization methods with anthropomorphic phantoms. AJR Am J Roentgenol 2015; 204:117-23. [PMID: 25539246 DOI: 10.2214/ajr.14.12763] [Citation(s) in RCA: 48] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE The purpose of this study was to study different optimization methods for reducing eye lens dose in head CT. MATERIALS AND METHODS Two anthropomorphic phantoms were scanned with a routine head CT protocol for evaluation of the brain that included bismuth shielding, gantry tilting, organ-based tube current modulation, or combinations of these techniques. Highsensitivity metal oxide semiconductor field effect transistor dosimeters were used to measure local equivalent doses in the head region. The relative changes in image noise and contrast were determined by ROI analysis. RESULTS The mean absorbed lens doses varied from 4.9 to 19.7 mGy and from 10.8 to 16.9 mGy in the two phantoms. The most efficient method for reducing lens dose was gantry tilting, which left the lenses outside the primary radiation beam, resulting in an approximately 75% decrease in lens dose. Image noise decreased, especially in the anterior part of the brain. The use of organ-based tube current modulation resulted in an approximately 30% decrease in lens dose. However, image noise increased as much as 30% in the posterior and central parts of the brain. With bismuth shields, it was possible to reduce lens dose as much as 25%. CONCLUSION Our results indicate that gantry tilt, when possible, is an effective method for reducing exposure of the eye lenses in CT of the brain without compromising image quality. Measurements in two different phantoms showed how patient geometry affects the optimization. When lenses can only partially be cropped outside the primary beam, organ-based tube current modulation or bismuth shields can be useful in lens dose reduction.
Collapse
|
8
|
Abdominal CT during pregnancy: a phantom study on the effect of patient centring on conceptus radiation dose and image quality. Eur Radiol 2014; 25:911-21. [DOI: 10.1007/s00330-014-3505-2] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2014] [Revised: 09/06/2014] [Accepted: 11/13/2014] [Indexed: 12/15/2022]
|
9
|
Brix G, Lechel U, Nekolla E, Griebel J, Becker C. Radiation protection issues in dynamic contrast-enhanced (perfusion) computed tomography. Eur J Radiol 2014; 84:2347-58. [PMID: 25480677 DOI: 10.1016/j.ejrad.2014.11.011] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2014] [Accepted: 11/11/2014] [Indexed: 11/25/2022]
Abstract
Dynamic contrast-enhanced (DCE) CT studies are increasingly used in both medical care and clinical trials to improve diagnosis and therapy management of the most common life-threatening diseases: stroke, coronary artery disease and cancer. It is thus the aim of this review to briefly summarize the current knowledge on deterministic and stochastic radiation effects relevant for patient protection, to present the essential concepts for determining radiation doses and risks associated with DCE-CT studies as well as representative results, and to discuss relevant aspects to be considered in the process of justification and optimization of these studies. For three default DCE-CT protocols implemented at a latest-generation CT system for cerebral, myocardial and cancer perfusion imaging, absorbed doses were measured by thermoluminescent dosimeters at an anthropomorphic body phantom and compared with thresholds for harmful (deterministic) tissue reactions. To characterize stochastic radiation risks of patients from these studies, life-time attributable cancer risks (LAR) were estimated using sex-, age-, and organ-specific risk models based on the hypothesis of a linear non-threshold dose-response relationship. For the brain, heart and pelvic cancer studies considered, local absorbed doses in the imaging field were about 100-190 mGy (total CTDI(vol), 200 mGy), 15-30 mGy (16 mGy) and 80-270 mGy (140 mGy), respectively. According to a recent publication of the International Commission on Radiological Protection (ICRP Publication 118, 2012), harmful tissue reactions of the cerebro- and cardiovascular systems as well as of the lenses of the eye become increasingly important at radiation doses of more than 0.5 Gy. The LARs estimated for the investigated cerebral and myocardial DCE-CT scenarios are less than 0.07% for males and 0.1% for females at an age of exposure of 40 years. For the considered tumor location and protocol, the corresponding LARs are more than 6 times as high. Stochastic radiation risks decrease substantially with age and are markedly higher for females than for males. To balance the diagnostic needs and patient protection, DCE-CT studies have to be strictly justified and carefully optimized in due consideration of the various aspects discussed in some detail in this review.
Collapse
Affiliation(s)
- Gunnar Brix
- Department of Medical and Occupational Radiation Protection, Federal Office for Radiation Protection, Ingolstädter Landstraße 1, D-85764 Oberschleissheim, Germany.
| | - Ursula Lechel
- Department of Medical and Occupational Radiation Protection, Federal Office for Radiation Protection, Ingolstädter Landstraße 1, D-85764 Oberschleissheim, Germany.
| | - Elke Nekolla
- Department of Medical and Occupational Radiation Protection, Federal Office for Radiation Protection, Ingolstädter Landstraße 1, D-85764 Oberschleissheim, Germany.
| | - Jürgen Griebel
- Department of Medical and Occupational Radiation Protection, Federal Office for Radiation Protection, Ingolstädter Landstraße 1, D-85764 Oberschleissheim, Germany.
| | - Christoph Becker
- Department of Clinical Radiology, Grosshadern Clinic, Hospital of the Ludwig-Maximilians University, Marchioninistraße 15, D-81377 Munich, Germany.
| |
Collapse
|
10
|
Radiation dose evaluation of dental cone beam computed tomography using an anthropomorphic adult head phantom. Radiat Phys Chem Oxf Engl 1993 2014. [DOI: 10.1016/j.radphyschem.2013.11.024] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
11
|
Dosimetric evaluation of a 256-slice computed tomography scanner. Radiol Med 2014; 119:871-7. [DOI: 10.1007/s11547-014-0400-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2013] [Accepted: 05/20/2013] [Indexed: 10/25/2022]
|
12
|
Pauwels R, Cockmartin L, Ivanauskaité D, Urbonienė A, Gavala S, Donta C, Tsiklakis K, Jacobs R, Bosmans H, Bogaerts R, Horner K. Estimating cancer risk from dental cone-beam CT exposures based on skin dosimetry. Phys Med Biol 2014; 59:3877-91. [DOI: 10.1088/0031-9155/59/14/3877] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|