• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4643627)   Today's Articles (10)   Subscriber (50574)
For: Carr SJ, Borreggine K, Heilman J, Griswold M, Walter BL. Novel magnetomechanical MR compatible vibrational device for producing kinesthetic illusion during fMRI. Med Phys 2014;40:112303. [PMID: 24320459 DOI: 10.1118/1.4824695] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]  Open
Number Cited by Other Article(s)
1
Travassos C, Sayal A, Direito B, Pereira J, Sousa T, Castelo-Branco M. Assessing MR-compatibility of somatosensory stimulation devices: A systematic review on testing methodologies. Front Neurosci 2023;17:1071749. [PMID: 36777636 PMCID: PMC9909190 DOI: 10.3389/fnins.2023.1071749] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2022] [Accepted: 01/03/2023] [Indexed: 01/27/2023]  Open
2
Beaulieu LD, Schneider C, Massé-Alarie H, Ribot-Ciscar E. A new method to elicit and measure movement illusions in stroke by means of muscle tendon vibration: the Standardized Kinesthetic Illusion Procedure (SKIP). Somatosens Mot Res 2020;37:28-36. [PMID: 31973656 DOI: 10.1080/08990220.2020.1713739] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
3
Vinci-Booher S, Sturgeon J, James T, James K. The MRItab: A MR-compatible touchscreen with video-display. J Neurosci Methods 2018;306:10-18. [PMID: 29803918 DOI: 10.1016/j.jneumeth.2018.05.018] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2018] [Revised: 05/22/2018] [Accepted: 05/23/2018] [Indexed: 10/16/2022]
4
Systematic Review of fMRI Compatible Devices: Design and Testing Criteria. Ann Biomed Eng 2017;45:1819-1835. [DOI: 10.1007/s10439-017-1853-1] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2017] [Accepted: 05/10/2017] [Indexed: 12/22/2022]
5
Findlater SE, Dukelow SP. Upper Extremity Proprioception After Stroke: Bridging the Gap Between Neuroscience and Rehabilitation. J Mot Behav 2016;49:27-34. [PMID: 27726645 DOI: 10.1080/00222895.2016.1219303] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
6
Illusory movements induced by tendon vibration in right- and left-handed people. Exp Brain Res 2014;233:375-83. [PMID: 25294499 DOI: 10.1007/s00221-014-4121-8] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2014] [Accepted: 09/29/2014] [Indexed: 10/24/2022]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA