Cook EL, Su KH, Higgins GS, Johnsen R, Bouhnik JP, McGowan DR. Data-driven gating (DDG)-based motion match for improved CTAC registration. EJNMMI Phys 2024; 11:42. [PMID: 38691232 DOI: 10.1186/s40658-024-00644-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2024] [Accepted: 04/24/2024] [Indexed: 05/03/2024] Open
Abstract
BACKGROUND Respiratory motion artefacts are a pitfall in thoracic PET/CT imaging. A source of these motion artefacts within PET images is the CT used for attenuation correction of the images. The arbitrary respiratory phase in which the helical CT ( CT helical ) is acquired often causes misregistration between PET and CT images, leading to inaccurate attenuation correction of the PET image. As a result, errors in tumour delineation or lesion uptake values can occur. To minimise the effect of motion in PET/CT imaging, a data-driven gating (DDG)-based motion match (MM) algorithm has been developed that estimates the phase of the CT helical , and subsequently warps this CT to a given phase of the respiratory cycle, allowing it to be phase-matched to the PET. A set of data was used which had four-dimensional CT (4DCT) acquired alongside PET/CT. The 4DCT allowed ground truth CT phases to be generated and compared to the algorithm-generated motion match CT (MMCT). Measurements of liver and lesion margin positions were taken across CT images to determine any differences and establish how well the algorithm performed concerning warping the CT helical to a given phase (end-of-expiration, EE). RESULTS Whilst there was a minor significance in the liver measurement between the 4DCT and MMCT ( p = 0.045 ), no significant differences were found between the 4DCT or MMCT for lesion measurements ( p = 1.0 ). In all instances, the CT helical was found to be significantly different from the 4DCT ( p < 0.001 ). Consequently, the 4DCT and MMCT can be considered equivalent with respect to warped CT generation, showing the DDG-based MM algorithm to be successful. CONCLUSION The MM algorithm successfully enables the phase-matching of a CT helical to the EE of a ground truth 4DCT. This would reduce the motion artefacts caused by PET/CT registration without requiring additional patient dose (required for a 4DCT).
Collapse
Affiliation(s)
- Ella L Cook
- Department of Oncology, University of Oxford, Oxford, UK
| | | | | | | | | | - Daniel R McGowan
- Department of Oncology, University of Oxford, Oxford, UK.
- Department of Medical Physics and Clinical Engineering, Oxford University Hospitals Foundation Trust, Oxford, UK.
| |
Collapse
|
2
|
Tsai YJ, Liu C. Joint motion estimation and penalized image reconstruction algorithm with anatomical priors for gated TOF-PET/CT. Phys Med Biol 2023; 68. [PMID: 36549009 DOI: 10.1088/1361-6560/acae19] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2022] [Accepted: 12/22/2022] [Indexed: 12/24/2022]
Abstract
The presence of respiratory motion not only degrades the reconstructed image but also limits the utilization of anatomical priors in emission tomography. In this study, we explore the potential application of a joint motion estimation and penalized image reconstruction algorithm using anatomical priors in gated time-of-flight positron emission tomography/computed tomography (PET/CT). The algorithm is able to warp both the activity image and the attenuation map to align them with the measured data with the facilitation of anatomical information contained in the attenuation map. Five patient datasets, three acquired in single-bed position and two acquired in whole-body continuous-bed-motion mode, are included. For each patient, the attenuation map is derived from a breath-hold CT. The Parallel Levels Sets (PLS) is chosen as a representative anatomical prior. In addition to demonstrating the reliability of the estimated motion and the benefits of incorporating anatomical prior, preliminary results also indicate that the algorithm shows the potential to reconstruct an activity image in the space corresponding to that of the attenuation map, which could be applied to address the potential misalignment issue in applications involving multiple PET acquisitions but a single CT.
Collapse
Affiliation(s)
- Yu-Jung Tsai
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT 06520, United States of America.,Canon Medical Research USA, Inc., Vernon Hills, IL 60061, United States of America
| | - Chi Liu
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT 06520, United States of America
| |
Collapse
|
3
|
Yamashita K, Miyaji N, Motegi K, Ito S, Terauchi T. [Effects of CT-based Attenuation Correction on PET Images Using Data-driven Respiratory Gating]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2021; 77:1317-1324. [PMID: 34803112 DOI: 10.6009/jjrt.2021_jsrt_77.11.1317] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE We applied deviceless, positron emission tomography/computed tomography(PET/CT) data-driven respiratory gating (DDG) to validate the effects of misalignment between PET and CT at various respiratory phases. METHODS A lung lesion was simulated using an NEMA IEC body phantom in which the background comprised hot spheres containing polystyrene foam beads. We acquired PET images as the phantom moved downwards and then stopped. Attenuation on computed tomography images acquired at the inspiratory, stationary, and expiratory phases was corrected after the phantom stopped moving. Normalized mean square error (NMSE), recovery coefficients (RCmax and RCmean) and volume were analyzed on DDG-PET images using CT-based attenuation correction. RESULTS The NMSE was closest to 0 in PET images corrected using the expiratory CT image. The RCmax was<1.0, and the RCmean was closest to 1.0 only in PET images corrected using the expiratory CT image. Volume was either underestimated or overestimated more according to the size of the spheres when the alignment of CT and PET images was greater. CONCLUSION We recommend using the expiratory but not the inspiratory phase when using DDG for PET/CT correction.
Collapse
Affiliation(s)
- Kosuke Yamashita
- Department of Nuclear Medicine, Cancer Institute Hospital of Japanese Foundation for Cancer Research.,Graduate School of Health Sciences, Kumamoto University
| | - Noriaki Miyaji
- Department of Nuclear Medicine, Cancer Institute Hospital of Japanese Foundation for Cancer Research
| | - Kazuki Motegi
- Department of Nuclear Medicine, Cancer Institute Hospital of Japanese Foundation for Cancer Research
| | - Shigeki Ito
- Faculty of Life Sciences, Kumamoto University
| | - Takashi Terauchi
- Department of Nuclear Medicine, Cancer Institute Hospital of Japanese Foundation for Cancer Research
| |
Collapse
|
4
|
Driscoll B, Vines D, Shek T, Publicover J, Yeung I, Breen S, Jaffray D. 4D-CT Attenuation Correction in Respiratory-Gated PET for Hypoxia Imaging: Is It Really Beneficial? ACTA ACUST UNITED AC 2021; 6:241-249. [PMID: 32548302 PMCID: PMC7289254 DOI: 10.18383/j.tom.2019.00027] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Previous literature has shown that 4D respiratory-gated positron emission tomography (PET) is beneficial for quantitative analysis and defining targets for boosting therapy. However the case for addition of a phase-matched 4D-computed tomography (CT) for attenuation correction (AC) is less clear. We seek to validate the use of 4D-CT for AC and investigate the impact of motion correction for low signal-to-background PET imaging of hypoxia using radiotracers such as FAZA and FMISO. A new insert for the Modus Medicals' QUASAR™ Programmable Respiratory Motion Phantom was developed in which a 3D-printed sphere was placed within the "lung" compartment while an additional compartment is added to simulate muscle/blood compartment required for hypoxia quantification. Experiments are performed at 4:1 or 2:1 signal-to-background ratio consistent with clinical FAZA and FMISO imaging. Motion blur was significant in terms of SUVmax, mean, and peak for motion ≥1 cm and could be significantly reduced (from 20% to 8% at 2-cm motion) for all 4D-PET-gated reconstructions. The effect of attenuation method on precision was significant (σ2 hCT-AC = 5.5%/4.7%/2.7% vs σ2 4D-CT-AC = 0.5%/0.6%/0.7% [max%/peak%/mean% variance]). The simulated hypoxic fraction also significantly decreased under conditions of 2-cm amplitude motion from 55% to 20% and was almost fully recovered (HF = 0.52 for phase-matched 4D-CT) using gated PET. 4D-gated PET is valuable under conditions of low radiotracer uptake found in hypoxia imaging. This work demonstrates the importance of using 4D-CT for AC when performing gated PET based on its significantly improved precision over helical CT.
Collapse
Affiliation(s)
- Brandon Driscoll
- Quantitative Imaging for Personalized Cancer Medicine Program-Techna Institute, University Health Network, Toronto, ON, Canada
| | - Douglass Vines
- Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, ON, Canada; and.,Department of Radiation Oncology, University of Toronto, Toronto, ON, Canada
| | - Tina Shek
- Quantitative Imaging for Personalized Cancer Medicine Program-Techna Institute, University Health Network, Toronto, ON, Canada
| | - Julia Publicover
- Quantitative Imaging for Personalized Cancer Medicine Program-Techna Institute, University Health Network, Toronto, ON, Canada
| | - Ivan Yeung
- Quantitative Imaging for Personalized Cancer Medicine Program-Techna Institute, University Health Network, Toronto, ON, Canada.,Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, ON, Canada; and.,Department of Radiation Oncology, University of Toronto, Toronto, ON, Canada
| | - Stephen Breen
- Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, ON, Canada; and.,Department of Radiation Oncology, University of Toronto, Toronto, ON, Canada
| | - David Jaffray
- Quantitative Imaging for Personalized Cancer Medicine Program-Techna Institute, University Health Network, Toronto, ON, Canada.,Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, ON, Canada; and.,Department of Radiation Oncology, University of Toronto, Toronto, ON, Canada
| |
Collapse
|
5
|
Tsai YJ, Bousse A, Arridge S, Stearns CW, Hutton BF, Thielemans K. Penalized PET/CT Reconstruction Algorithms With Automatic Realignment for Anatomical Priors. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2021. [DOI: 10.1109/trpms.2020.3025540] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
6
|
Zeng J, Bowen SR. Treatment Intensification in Locally Advanced/Unresectable NSCLC Through Combined Modality Treatment and Precision Dose Escalation. Semin Radiat Oncol 2021; 31:105-111. [PMID: 33610266 DOI: 10.1016/j.semradonc.2020.11.007] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
The best survival for patients with unresectable, locally advanced NSCLC is currently achieved through concurrent chemoradiation followed by durvalumab for a year. Despite the best standard of care treatment, the majority of patients still develop disease recurrence, which could be distant and/or local. Trials continue to try and improve outcomes for patients with unresectable NSCLC, typically through treatment intensification, with the addition of more systemic agents, or more radiation dose to the tumor. Although RTOG 0617 showed that uniform dose escalation across an unselected population of patients undergoing chemoradiation is not beneficial, efforts continue to select patients and tumor subsets that are likely to benefit from dose escalation. This review describes some of the ongoing therapeutic trials in unresectable NSCLC, with an emphasis on quantitative imaging and precision radiation dose escalation.
Collapse
Affiliation(s)
- Jing Zeng
- Department of Radiation Oncology, University of Washington School of Medicine, Seattle, WA.
| | - Stephen R Bowen
- Department of Radiation Oncology, University of Washington School of Medicine, Seattle, WA; Department of Radiology, University of Washington School of Medicine, Seattle, WA
| |
Collapse
|
7
|
Emond EC, Bousse A, Machado M, Porter J, Groves AM, Hutton BF, Thielemans K. Effect of attenuation mismatches in time of flight PET reconstruction. Phys Med Biol 2020; 65:085009. [PMID: 32101801 DOI: 10.1088/1361-6560/ab7a6f] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
While the pursuit of better time resolution in positron emission tomography (PET) is rapidly evolving, little work has been performed on time of flight (TOF) image quality at high time resolution in the presence of modelling inconsistencies. This works focuses on the effect of using the wrong attenuation map in the system model, causing perturbations in the reconstructed radioactivity image. Previous work has usually considered the effects to be local to the area where there is attenuation mismatch, and has shown that the quantification errors in this area tend to reduce with improved time resolution. This publication shows however that errors in the PET image at a distance from the mismatch increase with time resolution. The errors depend on the reconstruction algorithm used. We quantify the errors in the hypothetical case of perfect time resolution for maximum likelihood reconstructions. In addition, we perform reconstructions on simulated and patient data. In particular, for respiratory-gated reconstructions from a wrong attenuation map, increased errors are observed with improved time resolutions in areas close to the lungs (e.g. from 13.3% in non-TOF to up to 20.9% at 200 ps in the left ventricle).
Collapse
Affiliation(s)
- Elise C Emond
- Institute of Nuclear Medicine, University College London, London NW1 2BU, United Kingdom
| | | | | | | | | | | | | |
Collapse
|
8
|
Yang J, Liu J, Wiesinger F, Menini A, Zhu X, Hope TA, Seo Y, Larson PEZ. Developing an efficient phase-matched attenuation correction method for quiescent period PET in abdominal PET/MRI. Phys Med Biol 2018; 63:185002. [PMID: 30106008 DOI: 10.1088/1361-6560/aada26] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Respiratory motion causes misalignments between positron emission tomography (PET) and magnetic resonance (MR)-derived attenuation maps (µ-maps) in addition to artifacts on both PET and MR images in simultaneous PET/MRI for organs such as liver that can experience motion of several centimeters. To address this problem, we developed an efficient MR-based attenuation correction (MRAC) method to generate phase-matched µ-maps for quiescent period PET (PETQ) in abdominal PET/MRI. MRAC data was acquired with CIRcular Cartesian UnderSampling (CIRCUS) sampling during 100 s in free-breathing as an accelerated data acquisition strategy for phase-matched MRAC (MRACPM-CIRCUS). For comparison, MRAC data with raster (Default) k-space sampling was also acquired during 100 s in free-breathing (MRACPM-Default), and used to evaluate MRACPM-CIRCUS as well as un-matched MRAC (MRACUM) that was un-gated. We purposefully oversampled the MRACPM data to ensure we had enough information to capture all respiratory phases to make this comparison as robust as possible. The proposed MRACPM-CIRCUS was evaluated in 17 patients with 68Ga-DOTA-TOC PET/MRI exams, suspected of having neuroendocrine tumors or liver metastases. Effects of CIRCUS sampling for accelerating a data acquisition were evaluated by simulating the data acquisition time retrospectively in increments of 5 s. Effects of MRACPM-CIRCUS on PETQ were evaluated using uptake differences in the liver lesions (n = 35), compared to PETQ with MRACPM-Default and MRACUM. A Wilcoxon signed-rank test was performed to compare lesion uptakes between the MRAC methods. MRACPM-CIRCUS showed higher image quality compared to MRACPM-Default for the same acquisition times, demonstrating that a data acquisition time of 30 s was reasonable to achieve phase-matched µ-maps. Lesion update differences between MRACPM-CIRCUS (30 s) versus MRACPM-Default (reference, 100 s) were 0.1% ± 1.4% (range of -2.7% to 3.2%) and not significant (P > .05); while, the differences between MRACUM versus MRACPM-Default were 0.6% ± 11.4% with a large variation (range of -37% to 20%) and significant (P < .05). In conclusion, we demonstrated that a data acquisition of 30 s achieved phase-matched µ-maps when using specialized CIRCUS data sampling and phase-matched µ-maps improved PETQ quantification significantly.
Collapse
Affiliation(s)
- Jaewon Yang
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, United States of America. UCSF Physics Research Laboratory, 185 Berry Street, Suite 350, San Francisco, CA 94143-0946, United States of America. Author to whom any correspondence should be addressed
| | | | | | | | | | | | | | | |
Collapse
|
9
|
Comparison of the clinical performance of upper abdominal PET/DCE-MRI with and without concurrent respiratory motion correction (MoCo). Eur J Nucl Med Mol Imaging 2018; 45:2147-2154. [PMID: 29998420 DOI: 10.1007/s00259-018-4084-2] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2018] [Accepted: 06/29/2018] [Indexed: 12/22/2022]
Abstract
PURPOSE To compare the clinical performance of upper abdominal PET/DCE-MRI with and without concurrent respiratory motion correction (MoCo). METHODS MoCo PET/DCE-MRI of the upper abdomen was acquired in 44 consecutive oncologic patients and compared with non-MoCo PET/MRI. SUVmax and MTV of FDG-avid upper abdominal malignant lesions were assessed on MoCo and non-MoCo PET images. Image quality was compared between MoCo DCE-MRI and non-MoCo CE-MRI, and between fused MoCo PET/MRI and fused non-MoCo PET/MRI images. RESULTS MoCo PET resulted in higher SUVmax (10.8 ± 5.45) than non-MoCo PET (9.62 ± 5.42) and lower MTV (35.55 ± 141.95 cm3) than non-MoCo PET (38.11 ± 198.14 cm3; p < 0.005 for both). The quality of MoCo DCE-MRI images (4.73 ± 0.5) was higher than that of non-MoCo CE-MRI images (4.53±0.71; p = 0.037). The quality of fused MoCo-PET/MRI images (4.96 ± 0.16) was higher than that of fused non-MoCo PET/MRI images (4.39 ± 0.66; p < 0.005). CONCLUSION MoCo PET/MRI provided qualitatively better images than non-MoCo PET/MRI, and upper abdominal malignant lesions demonstrated higher SUVmax and lower MTV on MoCo PET/MRI.
Collapse
|
10
|
Bousse A, Manber R, Holman BF, Atkinson D, Arridge S, Ourselin S, Hutton BF, Thielemans K. Evaluation of a direct motion estimation/correction method in respiratory-gated PET/MRI with motion-adjusted attenuation. Med Phys 2017; 44:2379-2390. [DOI: 10.1002/mp.12253] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2016] [Revised: 03/01/2017] [Accepted: 03/21/2017] [Indexed: 11/10/2022] Open
Affiliation(s)
- Alexandre Bousse
- Institute of Nuclear Medicine; University College London; London NW1 2BU UK
| | - Richard Manber
- Institute of Nuclear Medicine; University College London; London NW1 2BU UK
| | - Beverley F. Holman
- Institute of Nuclear Medicine; University College London; London NW1 2BU UK
| | - David Atkinson
- Centre for Medical Imaging; University College London; London NW1 2PG UK
| | - Simon Arridge
- Centre for Medical Image Computing; University College London; London WC1E 7JE UK
| | - Sébastien Ourselin
- Centre for Medical Image Computing; University College London; London WC1E 7JE UK
| | - Brian F. Hutton
- Institute of Nuclear Medicine; University College London; London NW1 2BU UK
- Centre for Medical Radiation Physics; University of Wollongong; Wollongong NSW 2522 Australia
| | - Kris Thielemans
- Institute of Nuclear Medicine; University College London; London NW1 2BU UK
| |
Collapse
|
11
|
Kalantari F, Wang J. Attenuation correction in 4D-PET using a single-phase attenuation map and rigidity-adaptive deformable registration. Med Phys 2017; 44:522-532. [PMID: 27987223 DOI: 10.1002/mp.12063] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2016] [Revised: 12/03/2016] [Accepted: 12/05/2016] [Indexed: 11/11/2022] Open
Abstract
PURPOSE Four-dimensional positron emission tomography (4D-PET) imaging is a potential solution to the respiratory motion effect in the thoracic region. Computed tomography (CT)-based attenuation correction (AC) is an essential step toward quantitative imaging for PET. However, due to the temporal difference between 4D-PET and a single attenuation map from CT, typically available in routine clinical scanning, motion artifacts are observed in the attenuation-corrected PET images, leading to errors in tumor shape and uptake. We introduced a practical method to align single-phase CT with all other 4D-PET phases for AC. METHODS A penalized non-rigid Demons registration between individual 4D-PET frames without AC provides the motion vectors to be used for warping single-phase attenuation map. The non-rigid Demons registration was used to derive deformation vector fields (DVFs) between PET matched with the CT phase and other 4D-PET images. While attenuated PET images provide useful data for organ borders such as those of the lung and the liver, tumors cannot be distinguished from the background due to loss of contrast. To preserve the tumor shape in different phases, an ROI-covering tumor was excluded from nonrigid transformation. Instead the mean DVF of the central region of the tumor was assigned to all voxels in the ROI. This process mimics a rigid transformation of the tumor along with a nonrigid transformation of other organs. A 4D-XCAT phantom with spherical lung tumors, with diameters ranging from 10 to 40 mm, was used to evaluate the algorithm. The performance of the proposed hybrid method for attenuation map estimation was compared to (a) the Demons nonrigid registration only and (b) a single attenuation map based on quantitative parameters in individual PET frames. RESULTS Motion-related artifacts were significantly reduced in the attenuation-corrected 4D-PET images. When a single attenuation map was used for all individual PET frames, the normalized root-mean-square error (NRMSE) values in tumor region were 49.3% (STD: 8.3%), 50.5% (STD: 9.3%), 51.8% (STD: 10.8%) and 51.5% (STD: 12.1%) for 10-mm, 20-mm, 30-mm, and 40-mm tumors, respectively. These errors were reduced to 11.9% (STD: 2.9%), 13.6% (STD: 3.9%), 13.8% (STD: 4.8%), and 16.7% (STD: 9.3%) by our proposed method for deforming the attenuation map. The relative errors in total lesion glycolysis (TLG) values were -0.25% (STD: 2.87%) and 3.19% (STD: 2.35%) for 30-mm and 40-mm tumors, respectively, in proposed method. The corresponding values for Demons method were 25.22% (STD: 14.79%) and 18.42% (STD: 7.06%). Our proposed hybrid method outperforms the Demons method especially for larger tumors. For tumors smaller than 20 mm, nonrigid transformation could also provide quantitative results. CONCLUSION Although non-AC 4D-PET frames include insignificant anatomical information, they are still useful to estimate the DVFs to align the attenuation map for accurate AC. The proposed hybrid method can recover the AC-related artifacts and provide quantitative AC-PET images.
Collapse
Affiliation(s)
- Faraz Kalantari
- Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, TX, 75235-8808, USA
| | - Jing Wang
- Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, TX, 75235-8808, USA
| |
Collapse
|
12
|
Cui Y, Bowsher J, Cai J, Yin FF. Impact of moving target on measurement accuracy in 3D and 4D PET imaging-a phantom study. Adv Radiat Oncol 2016; 2:94-100. [PMID: 28740918 PMCID: PMC5514228 DOI: 10.1016/j.adro.2016.12.002] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2016] [Revised: 11/28/2016] [Accepted: 12/02/2016] [Indexed: 12/25/2022] Open
Abstract
PURPOSE The purpose of this study was to evaluate the impact of tumor motion on maximum standardized uptake value (SUVmax) and metabolic tumor volume (MTV) measurements in both 3-dimensional and respiratory-correlated, 4-dimensional positron emission tomography (PET) imaging. We also evaluated the effect of implementing different attenuation correction methods in 4-dimensional PET image reconstruction on SUVmax and MTV. METHODS AND MATERIALS An anthropomorphic thorax phantom with a spherical ball as a surrogate for a tumor was used. Different types of motion were imposed on the ball to mimic a patient's breathing motion. Three-dimensional PET imaging of the phantom without tumor motion was performed and used as the reference. The ball was then set in motion with different breathing motion traces and imaged with both 3- and 4-dimensional PET methods. The clinical 4-dimensional PET imaging protocol was modified so that 3 different types of attenuation correction images were used for reconstructions: the same free-breathing computed tomography (CT) for all PET phases, the same average intensity projection CT for all PET phases, and 4-dimensional CT for phase-matched attenuation correction. Tumor SUVmax and MTV values that were measured from the moving phantom were compared with the reference values. RESULTS SUVmax that was measured in 3-dimensional PET imaging was different from the reference value by 20.4% on average for the motions that were investigated; this difference decreased to 2.6% with 4-dimensional PET imaging. The measurement of MTV in 4-dimensional PET also showed a similar magnitude of reduction of deviation compared with 3-dimensional PET. Four-dimensional PET with use of phase-matched 4-dimensional CT for attenuation correction showed less variation in SUVmax and MTV among phases compared with 4-dimensional PET with free-breathing CT or average intensity projection CT for attenuation correction. CONCLUSIONS Four-dimensional PET imaging reduces the impact of motion on measured SUVmax and MTV when compared with 3-dimensional PET imaging. Clinical 4-dimensional PET imaging protocols should consider phase-matched 4-dimensional CT imaging for attenuation correction to achieve more accurate measurements.
Collapse
Affiliation(s)
- Yunfeng Cui
- Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina
| | - James Bowsher
- Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina
| | - Jing Cai
- Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina
| | - Fang-Fang Yin
- Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina
| |
Collapse
|
13
|
Holman BF, Cuplov V, Hutton BF, Groves AM, Thielemans K. The effect of respiratory induced density variations on non-TOF PET quantitation in the lung. Phys Med Biol 2016; 61:3148-63. [PMID: 27007013 DOI: 10.1088/0031-9155/61/8/3148] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
Accurate PET quantitation requires a matched attenuation map. Obtaining matched CT attenuation maps in the thorax is difficult due to the respiratory cycle which causes both motion and density changes. Unlike with motion, little attention has been given to the effects of density changes in the lung on PET quantitation. This work aims to explore the extent of the errors caused by pulmonary density attenuation map mismatch on dynamic and static parameter estimates. Dynamic XCAT phantoms were utilised using clinically relevant (18)F-FDG and (18)F-FMISO time activity curves for all organs within the thorax to estimate the expected parameter errors. The simulations were then validated with PET data from 5 patients suffering from idiopathic pulmonary fibrosis who underwent PET/Cine-CT. The PET data were reconstructed with three gates obtained from the Cine-CT and the average Cine-CT. The lung TACs clearly displayed differences between true and measured curves with error depending on global activity distribution at the time of measurement. The density errors from using a mismatched attenuation map were found to have a considerable impact on PET quantitative accuracy. Maximum errors due to density mismatch were found to be as high as 25% in the XCAT simulation. Differences in patient derived kinetic parameter estimates and static concentration between the extreme gates were found to be as high as 31% and 14%, respectively. Overall our results show that respiratory associated density errors in the attenuation map affect quantitation throughout the lung, not just regions near boundaries. The extent of this error is dependent on the activity distribution in the thorax and hence on the tracer and time of acquisition. Consequently there may be a significant impact on estimated kinetic parameters throughout the lung.
Collapse
Affiliation(s)
- Beverley F Holman
- Institute of Nuclear Medicine, UCLH, 235 Euston Road (T-5), London, NW1 2BU, UK
| | | | | | | | | |
Collapse
|
14
|
Lee TC, Alessio AM, Miyaoka RM, Kinahan PE. Morphology supporting function: attenuation correction for SPECT/CT, PET/CT, and PET/MR imaging. THE QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING : OFFICIAL PUBLICATION OF THE ITALIAN ASSOCIATION OF NUCLEAR MEDICINE (AIMN) [AND] THE INTERNATIONAL ASSOCIATION OF RADIOPHARMACOLOGY (IAR), [AND] SECTION OF THE SOCIETY OF... 2016; 60:25-39. [PMID: 26576737 PMCID: PMC5262384] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Both SPECT, and in particular PET, are unique in medical imaging for their high sensitivity and direct link to a physical quantity, i.e. radiotracer concentration. This gives PET and SPECT imaging unique capabilities for accurately monitoring disease activity for the purposes of clinical management or therapy development. However, to achieve a direct quantitative connection between the underlying radiotracer concentration and the reconstructed image values several confounding physical effects have to be estimated, notably photon attenuation and scatter. With the advent of dual-modality SPECT/CT, PET/CT, and PET/MR scanners, the complementary CT or MR image data can enable these corrections, although there are unique challenges for each combination. This review covers the basic physics underlying photon attenuation and scatter and summarizes technical considerations for multimodal imaging with regard to PET and SPECT quantification and methods to address the challenges for each multimodal combination.
Collapse
Affiliation(s)
- Tzu C Lee
- Department of Bioengineering, University of Washington, Seattle, WA, USA -
| | | | | | | |
Collapse
|
15
|
Bousse A, Bertolli O, Atkinson D, Arridge S, Ourselin S, Hutton BF, Thielemans K. Maximum-likelihood joint image reconstruction and motion estimation with misaligned attenuation in TOF-PET/CT. Phys Med Biol 2016; 61:L11-9. [PMID: 26789205 DOI: 10.1088/0031-9155/61/3/l11] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
This work is an extension of our recent work on joint activity reconstruction/motion estimation (JRM) from positron emission tomography (PET) data. We performed JRM by maximization of the penalized log-likelihood in which the probabilistic model assumes that the same motion field affects both the activity distribution and the attenuation map. Our previous results showed that JRM can successfully reconstruct the activity distribution when the attenuation map is misaligned with the PET data, but converges slowly due to the significant cross-talk in the likelihood. In this paper, we utilize time-of-flight PET for JRM and demonstrate that the convergence speed is significantly improved compared to JRM with conventional PET data.
Collapse
Affiliation(s)
- Alexandre Bousse
- Institute of Nuclear Medicine, University College London, London NW1 2BU, UK
| | | | | | | | | | | | | |
Collapse
|
16
|
Bousse A, Bertolli O, Atkinson D, Arridge S, Ourselin S, Hutton BF, Thielemans K. Maximum-Likelihood Joint Image Reconstruction/Motion Estimation in Attenuation-Corrected Respiratory Gated PET/CT Using a Single Attenuation Map. IEEE TRANSACTIONS ON MEDICAL IMAGING 2016; 35:217-28. [PMID: 26259017 DOI: 10.1109/tmi.2015.2464156] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
This work provides an insight into positron emission tomography (PET) joint image reconstruction/motion estimation (JRM) by maximization of the likelihood, where the probabilistic model accounts for warped attenuation. Our analysis shows that maximum-likelihood (ML) JRM returns the same reconstructed gates for any attenuation map (μ-map) that is a deformation of a given μ-map, regardless of its alignment with the PET gates. We derived a joint optimization algorithm accordingly, and applied it to simulated and patient gated PET data. We first evaluated the proposed algorithm on simulations of respiratory gated PET/CT data based on the XCAT phantom. Our results show that independently of which μ-map is used as input to JRM: (i) the warped μ-maps correspond to the gated μ-maps, (ii) JRM outperforms the traditional post-registration reconstruction and consolidation (PRRC) for hot lesion quantification and (iii) reconstructed gated PET images are similar to those obtained with gated μ-maps. This suggests that a breath-held μ-map can be used. We then applied JRM on patient data with a μ-map derived from a breath-held high resolution CT (HRCT), and compared the results with PRRC, where each reconstructed PET image was obtained with a corresponding cine-CT gated μ-map. Results show that JRM with breath-held HRCT achieves similar reconstruction to that using PRRC with cine-CT. This suggests a practical low-dose solution for implementation of motion-corrected respiratory gated PET/CT.
Collapse
|