Darne CD, Robertson DG, Alsanea F, Collins-Fekete CA, Beddar S. A novel proton-integrating radiography system design using a monolithic scintillator detector: experimental studies. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT 2022; 1027:166077. [PMID: 35221402 PMCID: PMC8872121 DOI: 10.1016/j.nima.2021.166077] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Research on proton-based imaging systems aims to improve treatment planning, internal anatomy visualization, and patient alignment for proton radiotherapy. The purpose of this study was to demonstrate a new proton radiography system design consisting of a monolithic plastic scintillator volume and two optical cameras for use with scanning proton pencil beams. Unlike the thin scintillating plates currently used for proton radiography, the plastic scintillator volume (20 × 20 × 20 cm3) captures a wider distribution of proton beam energy depositions and avoids proton-beam modulation. The proton imaging system's characteristics were tested using image uniformity (2.6% over a 5 × 5 cm2 area), stability (0.37%), and linearity (R2 = 1) studies. We used the light distribution produced within the plastic scintillator to generate proton radiographs via two different approaches: (a) integrating light by using a camera placed along the beam axis, and (b) capturing changes to the proton Bragg peak positions with a camera placed perpendicularly to the beam axis. The latter method was used to plot and evaluate relative shifts in percentage depth light (PDL) profiles of proton beams with and without a phantom in the beam path. A curvelet minimization algorithm used differences in PDL profiles to reconstruct and refine the phantom water-equivalent thickness (WET) map. Gammex phantoms were used to compare the proton radiographs generated by these two methods. The relative accuracies in calculating WET of the phantoms using the calibration-based beam-integration (and the PDL) methods were -0.18 ± 0.35% (-0.29 ± 3.11%), -0.11 ± 0.51% (-0.15 ± 2.64%), -2.94 ± 1.20% (-0.75 ± 6.11%), and -1.65 ± 0.35% (0.36 ± 3.93%) for solid water, adipose, cortical bone, and PMMA, respectively. Further exploration of this unique multicamera-based imaging system is warranted and could lead to clinical applications that improve treatment planning and patient alignment for proton radiotherapy.
Collapse
Affiliation(s)
- Chinmay D Darne
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
| | - Daniel G Robertson
- Division of Medical Physics, Department of Radiation Oncology, Mayo Clinic Arizona, Phoenix, AZ 85054, USA
| | - Fahed Alsanea
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
| | | | - Sam Beddar
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
| |
Collapse
|
2
|
Darne CD, Alsanea F, Robertson DG, Guan F, Pan T, Grosshans D, Beddar S. A proton imaging system using a volumetric liquid scintillator: a preliminary study. Biomed Phys Eng Express 2019; 5:045032. [PMID: 32194988 PMCID: PMC7082085 DOI: 10.1088/2057-1976/ab2e4a] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
With the expansion of proton radiotherapy for cancer treatments, it has become important to explore proton-based imaging technologies to increase the accuracy of proton treatment planning, alignment, and verification. The purpose of this study is to demonstrate the feasibility of using a volumetric liquid scintillator to generate proton radiographs at a clinically relevant energy (180 MeV) using an integrating detector approach. The volumetric scintillator detector is capable of capturing a wide distribution of residual proton beam energies from a single beam irradiation. It has the potential to reduce acquisition time and imaging dose compared to other proton radiography methods. The imaging system design is comprised of a volumetric (20 × 20 × 20 cm3) organic liquid scintillator working as a residual-range detector and a charge-coupled device (CCD) placed along the beams'-eye-view for capturing radiographic projections. The scintillation light produced within the scintillator volume in response to a 3-dimensional distribution of residual proton beam energies is captured by the CCD as a 2-dimensional grayscale image. A light intensity-to-water equivalent thickness (WET) curve provided WET values based on measured light intensities. The imaging properties of the system, including its contrast, signal-to-noise ratio, and spatial resolution (0.19 line-pairs/mm) were determined. WET values for selected Gammex phantom inserts including solid water, acrylic, and cortical bone were calculated from the radiographs with a relative accuracy of -0.82%, 0.91%, and -2.43%, respectively. Image blurring introduced by system optics was accounted for, resulting in sharper image features. Finally, the system's ability to reconstruct proton CT images from radiographic projections was demonstrated using a filtered back-projection algorithm. The WET retrieved from the reconstructed CT slice was within 0.3% of the WET obtained from MC. In this work, the viability of a cumulative approach to proton imaging using a volumetric liquid scintillator detector and at a clinically-relevant energy was demonstrated.
Collapse
Affiliation(s)
- Chinmay D Darne
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
| | - Fahed Alsanea
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
- The University of Texas MD Anderson UTHealth Graduate School of Biomedical Sciences, Houston, TX 77030, USA
| | | | - Fada Guan
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
| | - Tinsu Pan
- The University of Texas MD Anderson UTHealth Graduate School of Biomedical Sciences, Houston, TX 77030, USA
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
| | - David Grosshans
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
| | - Sam Beddar
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
- The University of Texas MD Anderson UTHealth Graduate School of Biomedical Sciences, Houston, TX 77030, USA
| |
Collapse
|