1
|
Gu X, Xue W, Sun Y, Qi X, Luo X, He Y. Magnetic resonance image restoration via least absolute deviations measure with isotropic total variation constraint. MATHEMATICAL BIOSCIENCES AND ENGINEERING : MBE 2023; 20:10590-10609. [PMID: 37322950 DOI: 10.3934/mbe.2023468] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
This paper presents a magnetic resonance image deblurring and denoising model named the isotropic total variation regularized least absolute deviations measure (LADTV). More specifically, the least absolute deviations term is first adopted to measure the violation of the relation between the desired magnetic resonance image and the observed image, and to simultaneously suppress the noise that may corrupt the desired image. Then, in order to preserve the smoothness of the desired image, we introduce an isotropic total variation constraint, yielding the proposed restoration model LADTV. Finally, an alternating optimization algorithm is developed to solve the associated minimization problem. Comparative experiments on clinical data demonstrate the effectiveness of our approach to synchronously deblur and denoise magnetic resonance image.
Collapse
Affiliation(s)
- Xiaolei Gu
- Department of Radiology, Maanshan People's Hospital, Maanshan, China
| | - Wei Xue
- School of Computer Science and Technology, Anhui University of Technology, Maanshan, China
| | - Yanhong Sun
- School of Civil Engineering and Architecture, Anhui University of Technology, Maanshan, China
| | - Xuan Qi
- Department of Radiology, Maanshan People's Hospital, Maanshan, China
| | - Xiao Luo
- Department of Radiology, Maanshan People's Hospital, Maanshan, China
| | - Yongsheng He
- Department of Radiology, Maanshan People's Hospital, Maanshan, China
| |
Collapse
|
2
|
Denoising Diffusion MRI via Graph Total Variance in Spatioangular Domain. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE 2021; 2021:4645544. [PMID: 34917166 PMCID: PMC8670899 DOI: 10.1155/2021/4645544] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/09/2021] [Revised: 11/17/2021] [Accepted: 11/20/2021] [Indexed: 11/17/2022]
Abstract
Diffusion MRI (DMRI) plays an essential role in diagnosing brain disorders related to white matter abnormalities. However, it suffers from heavy noise, which restricts its quantitative analysis. The total variance (TV) regularization is an effective noise reduction technique that penalizes noise-induced variances. However, existing TV-based denoising methods only focus on the spatial domain, overlooking that DMRI data lives in a combined spatioangular domain. It eventually results in an unsatisfactory noise reduction effect. To resolve this issue, we propose to remove the noise in DMRI using graph total variance (GTV) in the spatioangular domain. Expressly, we first represent the DMRI data using a graph, which encodes the geometric information of sampling points in the spatioangular domain. We then perform effective noise reduction using the powerful GTV regularization, which penalizes the noise-induced variances on the graph. GTV effectively resolves the limitation in existing methods, which only rely on spatial information for removing the noise. Extensive experiments on synthetic and real DMRI data demonstrate that GTV can remove the noise effectively and outperforms state-of-the-art methods.
Collapse
|
3
|
Mishro PK, Agrawal S, Panda R, Abraham A. A Survey on State-of-the-art Denoising Techniques for Brain Magnetic Resonance Images. IEEE Rev Biomed Eng 2021; 15:184-199. [PMID: 33513109 DOI: 10.1109/rbme.2021.3055556] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The accuracy of the magnetic resonance (MR) image diagnosis depends on the quality of the image, which degrades mainly due to noise and artifacts. The noise is introduced because of erroneous imaging environment or distortion in the transmission system. Therefore, denoising methods play an important role in enhancing the image quality. However, a tradeoff between denoising and preserving the structural details is required. Most of the existing surveys are conducted on a specific MR image modality or on limited denoising schemes. In this context, a comprehensive review on different MR image denoising techniques is inevitable. This survey suggests a new direction in categorizing the MR image denoising techniques. The categorization of the different image models used in medical image processing serves as the basis of our classification. This study includes recent improvements on deep learning-based denoising methods alongwith important traditional MR image denoising methods. The major challenges and their scope of improvement are also discussed. Further, many more evaluation indices are considered for a fair comparison. An elaborate discussion on selecting appropriate method and evaluation metric as per the kind of data is presented. This study may encourage researchers for further work in this domain.
Collapse
|
4
|
Hui SCN, Zhang T, Shi L, Wang D, Ip CB, Chu WCW. Automated segmentation of abdominal subcutaneous adipose tissue and visceral adipose tissue in obese adolescent in MRI. Magn Reson Imaging 2017; 45:97-104. [PMID: 29017799 DOI: 10.1016/j.mri.2017.09.016] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2017] [Accepted: 09/24/2017] [Indexed: 12/18/2022]
Abstract
PURPOSE To develop a reliable and reproducible automatic technique to segment and measure SAT and VAT based on MRI. MATERIALS AND METHODS Chemical-shift water-fat MRI were taken on twelve obese adolescents (mean age: 16.1±0.6, BMI: 31.3±2.3) recruited under the health monitoring program. The segmentation applied a spoke template created using Midpoint Circle algorithm followed by Bresenham's Line algorithm to detect narrow connecting regions between subcutaneous and visceral adipose tissues. Upon satisfaction of given constrains, a cut was performed to separate SAT and VAT. Bone marrow was consisted in pelvis and femur. By using the intensity difference in T2*, a mask was created to extract bone marrow adipose tissue (MAT) from VAT. Validation was performed using a semi-automatic method. Pearson coefficient, Bland-Altman plot and intra-class coefficient (ICC) were applied to measure accuracy and reproducibility. RESULTS Pearson coefficient indicated that results from the proposed method achieved high correlation with the semi-automatic method. Bland-Altman plot and ICC showed good agreement between the two methods. Lowest ICC was obtained in VAT segmentation at lower regions of the abdomen while the rests were all above 0.80. ICC (0.98-0.99) also indicated the proposed method performed good reproducibility. CONCLUSION No user interaction was required during execution of the algorithm and the segmented images and volume results were given as output. This technique utilized the feature in the regions connecting subcutaneous and visceral fat and T2* intensity difference in bone marrow to achieve volumetric measurement of various types of adipose tissue in abdominal site.
Collapse
Affiliation(s)
- Steve C N Hui
- Department of Imaging and Interventional Radiology, Prince of Wales Hospital, The Chinese University of Hong Kong, Sha Tin, New Territories, Hong Kong
| | - Teng Zhang
- Department of Imaging and Interventional Radiology, Prince of Wales Hospital, The Chinese University of Hong Kong, Sha Tin, New Territories, Hong Kong
| | - Lin Shi
- Department of Medicine and Therapeutics, Prince of Wales Hospital, The Chinese University of Hong Kong, Sha Tin, New Territories, Hong Kong; Chow Yuk Ho Technology Centre for Innovative Medicine, Prince of Wales Hospital, The Chinese University of Hong Kong, Sha Tin, New Territories, Hong Kong
| | - Defeng Wang
- Department of Imaging and Interventional Radiology, Prince of Wales Hospital, The Chinese University of Hong Kong, Sha Tin, New Territories, Hong Kong
| | - Chei-Bing Ip
- Department of Imaging and Interventional Radiology, Prince of Wales Hospital, The Chinese University of Hong Kong, Sha Tin, New Territories, Hong Kong
| | - Winnie C W Chu
- Department of Imaging and Interventional Radiology, Prince of Wales Hospital, The Chinese University of Hong Kong, Sha Tin, New Territories, Hong Kong.
| |
Collapse
|
5
|
Maitree R, Perez-Carrillo GJG, Shimony JS, Gach HM, Chundury A, Roach M, Li HH, Yang D. Adaptive anatomical preservation optimal denoising for radiation therapy daily MRI. J Med Imaging (Bellingham) 2017; 4:034004. [PMID: 28894763 DOI: 10.1117/1.jmi.4.3.034004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2017] [Accepted: 08/09/2017] [Indexed: 11/14/2022] Open
Abstract
Low-field magnetic resonance imaging (MRI) has recently been integrated with radiation therapy systems to provide image guidance for daily cancer radiation treatments. The main benefit of the low-field strength is minimal electron return effects. The main disadvantage of low-field strength is increased image noise compared to diagnostic MRIs conducted at 1.5 T or higher. The increased image noise affects both the discernibility of soft tissues and the accuracy of further image processing tasks for both clinical and research applications, such as tumor tracking, feature analysis, image segmentation, and image registration. An innovative method, adaptive anatomical preservation optimal denoising (AAPOD), was developed for optimal image denoising, i.e., to maximally reduce noise while preserving the tissue boundaries. AAPOD employs a series of adaptive nonlocal mean (ANLM) denoising trials with increasing denoising filter strength (i.e., the block similarity filtering parameter in the ANLM algorithm), and then detects the tissue boundary losses on the differences of sequentially denoised images using a zero-crossing edge detection method. The optimal denoising filter strength per voxel is determined by identifying the denoising filter strength value at which boundary losses start to appear around the voxel. The final denoising result is generated by applying the ANLM denoising method with the optimal per-voxel denoising filter strengths. The experimental results demonstrated that AAPOD was capable of reducing noise adaptively and optimally while avoiding tissue boundary losses. AAPOD is useful for improving the quality of MRIs with low-contrast-to-noise ratios and could be applied to other medical imaging modalities, e.g., computed tomography.
Collapse
Affiliation(s)
- Rapeepan Maitree
- Washington University School of Medicine, Department of Radiation Oncology, St. Louis, Missouri, United States
| | - Gloria J Guzman Perez-Carrillo
- Washington University School of Medicine, Mallinckrodt Institute of Radiology, St. Louis, Missouri, United States.,University of Arizona, Department of Radiology, Tucson, Arizona, United States
| | - Joshua S Shimony
- Washington University School of Medicine, Mallinckrodt Institute of Radiology, St. Louis, Missouri, United States
| | - H Michael Gach
- Washington University School of Medicine, Department of Radiation Oncology, St. Louis, Missouri, United States.,Washington University School of Medicine, Mallinckrodt Institute of Radiology, St. Louis, Missouri, United States.,Washington University School of Medicine, Department of Biomedical Engineering, St. Louis, Missouri, United States
| | - Anupama Chundury
- Washington University School of Medicine, Department of Radiation Oncology, St. Louis, Missouri, United States
| | - Michael Roach
- Washington University School of Medicine, Department of Radiation Oncology, St. Louis, Missouri, United States
| | - H Harold Li
- Washington University School of Medicine, Department of Radiation Oncology, St. Louis, Missouri, United States
| | - Deshan Yang
- Washington University School of Medicine, Department of Radiation Oncology, St. Louis, Missouri, United States.,Washington University School of Medicine, Department of Biomedical Engineering, St. Louis, Missouri, United States
| |
Collapse
|
6
|
Liu RW, Shi L, Yu SCH, Xiong N, Wang D. Reconstruction of Undersampled Big Dynamic MRI Data Using Non-Convex Low-Rank and Sparsity Constraints. SENSORS (BASEL, SWITZERLAND) 2017; 17:E509. [PMID: 28273827 PMCID: PMC5375795 DOI: 10.3390/s17030509] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/10/2016] [Revised: 02/16/2017] [Accepted: 02/20/2017] [Indexed: 11/17/2022]
Abstract
Dynamic magnetic resonance imaging (MRI) has been extensively utilized for enhancing medical living environment visualization, however, in clinical practice it often suffers from long data acquisition times. Dynamic imaging essentially reconstructs the visual image from raw (k,t)-space measurements, commonly referred to as big data. The purpose of this work is to accelerate big medical data acquisition in dynamic MRI by developing a non-convex minimization framework. In particular, to overcome the inherent speed limitation, both non-convex low-rank and sparsity constraints were combined to accelerate the dynamic imaging. However, the non-convex constraints make the dynamic reconstruction problem difficult to directly solve through the commonly-used numerical methods. To guarantee solution efficiency and stability, a numerical algorithm based on Alternating Direction Method of Multipliers (ADMM) is proposed to solve the resulting non-convex optimization problem. ADMM decomposes the original complex optimization problem into several simple sub-problems. Each sub-problem has a closed-form solution or could be efficiently solved using existing numerical methods. It has been proven that the quality of images reconstructed from fewer measurements can be significantly improved using non-convex minimization. Numerous experiments have been conducted on two in vivo cardiac datasets to compare the proposed method with several state-of-the-art imaging methods. Experimental results illustrated that the proposed method could guarantee the superior imaging performance in terms of quantitative and visual image quality assessments.
Collapse
Affiliation(s)
- Ryan Wen Liu
- Department of Imaging and Interventional Radiology, The Chinese University of Hong Kong, Shatin 999077, N.T., Hong Kong, China.
| | - Lin Shi
- Department of Medicine and Therapeutics, The Chinese University of Hong Kong, Shatin 999077, N.T., Hong Kong, China.
- Chow Yuk Ho Technology Center for Innovative Medicine, The Chinese University of Hong Kong, Shatin 999077, N.T., Hong Kong, China.
| | - Simon Chun Ho Yu
- Department of Imaging and Interventional Radiology, The Chinese University of Hong Kong, Shatin 999077, N.T., Hong Kong, China.
| | - Naixue Xiong
- Department of Mathematics and Computer Science, Northeastern State University, Tahlequah, OK 74464, USA.
| | - Defeng Wang
- Department of Imaging and Interventional Radiology, The Chinese University of Hong Kong, Shatin 999077, N.T., Hong Kong, China.
- Research Center for Medical Image Computing, The Chinese University of Hong Kong, Shatin 999077, N.T., Hong Kong, China.
- Shenzhen Research Institute, The Chinese University of Hong Kong, Shenzhen 518057, China.
| |
Collapse
|
7
|
Effective Alternating Direction Optimization Methods for Sparsity-Constrained Blind Image Deblurring. SENSORS 2017; 17:s17010174. [PMID: 28106764 PMCID: PMC5298747 DOI: 10.3390/s17010174] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/01/2016] [Revised: 01/04/2017] [Accepted: 01/04/2017] [Indexed: 11/29/2022]
Abstract
Single-image blind deblurring for imaging sensors in the Internet of Things (IoT) is a challenging ill-conditioned inverse problem, which requires regularization techniques to stabilize the image restoration process. The purpose is to recover the underlying blur kernel and latent sharp image from only one blurred image. Under many degraded imaging conditions, the blur kernel could be considered not only spatially sparse, but also piecewise smooth with the support of a continuous curve. By taking advantage of the hybrid sparse properties of the blur kernel, a hybrid regularization method is proposed in this paper to robustly and accurately estimate the blur kernel. The effectiveness of the proposed blur kernel estimation method is enhanced by incorporating both the L1-norm of kernel intensity and the squared L2-norm of the intensity derivative. Once the accurate estimation of the blur kernel is obtained, the original blind deblurring can be simplified to the direct deconvolution of blurred images. To guarantee robust non-blind deconvolution, a variational image restoration model is presented based on the L1-norm data-fidelity term and the total generalized variation (TGV) regularizer of second-order. All non-smooth optimization problems related to blur kernel estimation and non-blind deconvolution are effectively handled by using the alternating direction method of multipliers (ADMM)-based numerical methods. Comprehensive experiments on both synthetic and realistic datasets have been implemented to compare the proposed method with several state-of-the-art methods. The experimental comparisons have illustrated the satisfactory imaging performance of the proposed method in terms of quantitative and qualitative evaluations.
Collapse
|