Entezam A, Fielding A, Bradley D, Fontanarosa D. Absorbed dose calculation for a realistic CT-derived mouse phantom irradiated with a standard Cs-137 cell irradiator using a Monte Carlo method. PLoS One 2023; 18:e0280765. [PMID: 36730280 PMCID: PMC9928120 DOI: 10.1371/journal.pone.0280765] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2022] [Accepted: 01/07/2023] [Indexed: 02/03/2023] Open
Abstract
Computed tomography (CT) derived Monte Carlo (MC) phantoms allow dose determination within small animal models that is not feasible with in-vivo dosimetry. The aim of this study was to develop a CT-derived MC phantom generated from a mouse with a xenograft tumour that could then be used to calculate both the dose heterogeneity in the tumour volume and out of field scattered dose for pre-clinical small animal irradiation experiments. A BEAMnrc Monte-Carlo model has been built of our irradiation system that comprises a lead collimator with a 1 cm diameter aperture fitted to a Cs-137 gamma irradiator. The MC model of the irradiation system was validated by comparing the calculated dose results with dosimetric film measurement in a polymethyl methacrylate (PMMA) phantom using a 1D gamma-index analysis. Dose distributions in the MC mouse phantom were calculated and visualized on the CT-image data. Dose volume histograms (DVHs) were generated for the tumour and organs at risk (OARs). The effect of the xenographic tumour volume on the scattered out of field dose was also investigated. The defined gamma index analysis criteria were met, indicating that our MC simulation is a valid model for MC mouse phantom dose calculations. MC dose calculations showed a maximum out of field dose to the mouse of 7% of Dmax. Absorbed dose to the tumour varies in the range 60%-100% of Dmax. DVH analysis demonstrated that tumour received an inhomogeneous dose of 12 Gy-20 Gy (for 20 Gy prescribed dose) while out of field doses to all OARs were minimized (1.29 Gy-1.38 Gy). Variation of the xenographic tumour volume exhibited no significant effect on the out of field scattered dose to OARs. The CT derived MC mouse model presented here is a useful tool for tumour dose verifications as well as investigating the doses to normal tissue (in out of field) for preclinical radiobiological research.
Collapse
Affiliation(s)
- Amir Entezam
- School of Clinical Sciences, Queensland University of Technology, Brisbane, QLD, Australia
- Centre for Biomedical Technologies, Queensland University of Technology, Brisbane, QLD, Australia
- Translational Research Institute, The University of Queensland, Brisbane, QLD, Australia
- * E-mail:
| | - Andrew Fielding
- Centre for Biomedical Technologies, Queensland University of Technology, Brisbane, QLD, Australia
- School of Chemistry and Physics, Faculty of Science, Queensland University of Technology, Brisbane, QLD, Australia
| | - David Bradley
- Centre for Applied Physics and Radiation Technologies, Sunway University, PJ, Malaysia
- Department of Physics, University of Surrey, Guildford, United Kingdom
| | - Davide Fontanarosa
- School of Clinical Sciences, Queensland University of Technology, Brisbane, QLD, Australia
- Centre for Biomedical Technologies, Queensland University of Technology, Brisbane, QLD, Australia
| |
Collapse
|
2
|
Zvolský M, Schaar M, Seeger S, Rakers S, Rafecas M. Development of a digital zebrafish phantom and its application to dedicated small-fish PET. Phys Med Biol 2022; 67. [DOI: 10.1088/1361-6560/ac71ee] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Accepted: 05/20/2022] [Indexed: 11/11/2022]
Abstract
Abstract
Objective. We are developing a small-fish positron emission tomography (PET) scanner dedicated to small aquatic animals relevant for biomedical and biological research, e.g. zebrafish. We plan to use Monte Carlo simulations to optimize its configuration and the required water-filled imaging chambers. Our objectives were: (1) to create a digital 3D zebrafish phantom using conventional micro-CT, (2) include the phantom into a simulated PET environment based on the framework GATE, and (3) investigate the effects of the water environment on the reconstructed images. Approach. To create the phantom, we performed ex vivo measurements of zebrafish specimen using a tabletop micro-CT and compared three methods to fixate the specimen. From segmented micro-CT images we created digital emission and transmission phantoms which were incorporated in GATE via tessellated volumes. Two chamber sizes were considered. For reference, a simulation with the zebrafish in air was implemented. The simulated data were reconstructed using CASToR. For attenuation correction, we used the exact attenuation information or a uniform distribution (only water). Several realizations of each scenario were performed; the reconstructed images were quantitatively evaluated. Main results. Fixation in formalin led to the best soft-tissue contrast at the cost of some specimen deformation. After attenuation correction, no significant differences were found between the reconstructed images. The PET images reflected well the higher uptake simulated in the brain and heart, despite their small size and surrounding background activity; the swim bladder (no activity) was clearly identified. The simplified attenuation map, consisting only of water, slightly worsened the images. Significance. A conventional micro-CT can provide sufficient image quality to generate numerical phantoms of small fish without contrast media. Such phantoms are useful to evaluate in-silico small aquatic animal imaging concepts and develop imaging protocols. Our results support the feasibility of zebrafish PET with an aqueous environment.
Collapse
|
3
|
Dose Rate Assessment Exercises with Stylized Phantom of Neon Flying Squid from Northwest Pacific. JOURNAL OF MARINE SCIENCE AND ENGINEERING 2022. [DOI: 10.3390/jmse10060782] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Radiation protection for non-human marine organisms still faces many challenges. To establish a more realistic radiation dosimetry model of cephalopods, this study developed a stylized phantom of neon flying squid (Ommastrephesbartramii) containing ten organs and tissues based on magnetic resonance imaging (MRI) technology. The internal and external dose conversion coefficients for eight radionuclides (134Cs, 137Cs, 131I, 110mAg, 60Co, 54Mn, 65Zn, 95Zr) of each organ/tissue were determined with Monte Carlo simulation using the Geant4 toolkit. Furthermore, with the reported coastal seawater radioactivity levels at the coastal area of Fukushima Daiichi Nuclear Power Plant after the accident in 2011 as the source term, the radiological dose rate for O. bartramii was evaluated with the stylized phantom developed in this study and with the conventional whole-organism ellipsoidal model in the ERICA Assessment Tool. Both results showed that the dose rate for O. bartramii derived from the FDNPP accident releases exceeded the generic no-effects screening benchmark level (10 μGy h−1).
Collapse
|
4
|
Choi DH, Ahn SH, Park K, Choi SH, Kim JS. Development of Total Lymphoid Irradiation (TLI)-Dedicated Shielding and Image-Guided System and Dose Evaluation Using 3D-Printed Rat Phantom. Front Vet Sci 2022; 9:832272. [PMID: 35664845 PMCID: PMC9159376 DOI: 10.3389/fvets.2022.832272] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2022] [Accepted: 04/04/2022] [Indexed: 11/13/2022] Open
Abstract
Purpose The purpose of this study is to propose a technique for delivering accurate doses in an image-guided system by developing an experimental setup optimized for total lymphoid irradiation (TLI) in rat lung transplantation. Materials and Methods In this study, a position-controlled shielding system was developed, and the dose was quantitatively evaluated using a 3D rat phantom and Gafchromic EBT3 film. In addition, we made our own image-guided system that allows the position of the rat and the shielding system to be confirmed during TLI. Results As a result of using the position-controlled shielding system, it was found that the doses to the head and lungs were reduced by 93.1 and 87.4%, respectively, of the prescribed doses. In addition, it was shown that the position of the shielding system can be easily confirmed by using the image guidance system. Conclusion A shielding apparatus that can control dose delivery according to the size of the rat can optimize the dose for TLI in rat lung transplantation.
Collapse
Affiliation(s)
- Dong Hyeok Choi
- Department of Medicine, Yonsei University College of Medicine, Seoul, South Korea
| | - So Hyun Ahn
- Department of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine, Seoul, South Korea
- *Correspondence: So Hyun Ahn
| | - Kwangwoo Park
- Department of Radiation Oncology, Yongin Severance Hospital, Yonsei University College of Medicine, Yongin, South Korea
- Kwangwoo Park
| | - Sang Hyun Choi
- Research Team of Radiological Physics and Engineering, Korea Institute of Radiological and Medical Sciences, Seoul, South Korea
| | - Jin Sung Kim
- Department of Medicine, Yonsei University College of Medicine, Seoul, South Korea
- Department of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine, Seoul, South Korea
| |
Collapse
|
5
|
Jeong WY, Kang MS, Lee H, Lee JH, Kim J, Han DW, Kim KS. Recent Trends in Photoacoustic Imaging Techniques for 2D Nanomaterial-Based Phototherapy. Biomedicines 2021; 9:80. [PMID: 33467616 PMCID: PMC7830416 DOI: 10.3390/biomedicines9010080] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2020] [Revised: 01/13/2021] [Accepted: 01/13/2021] [Indexed: 02/06/2023] Open
Abstract
A variety of 2D materials have been developed for therapeutic biomedical studies. Because of their excellent physicochemical properties, 2D materials can be used as carriers for delivering therapeutic agents into a lesion, leading to phototherapy. Various optical imaging techniques have been used for the monitoring of the treatment process. Among these, photoacoustic imaging has unique advantages including relatively deep imaging depth and large field of view with high spatial resolution. In this review article, we summarize the types of photoacoustic imaging systems used for phototherapy monitoring, then we explore contrast-enhanced photoacoustic images using 2D materials. Finally, photoacoustic image-guided phototherapies are discussed. We conclude that 2D material-based phototherapy can be efficiently monitored by photoacoustic imaging techniques.
Collapse
Affiliation(s)
- Woo Yeup Jeong
- School of Chemical Engineering, College of Engineering, Pusan National University, Busan 46241, Korea;
| | - Moon Sung Kang
- Department of Cogno-Mechatronics Engineering, College of Nanoscience & Nanotechnology, Pusan National University, Busan 46241, Korea; (M.S.K.); (H.L.)
| | - Haeni Lee
- Department of Cogno-Mechatronics Engineering, College of Nanoscience & Nanotechnology, Pusan National University, Busan 46241, Korea; (M.S.K.); (H.L.)
| | - Jong Hun Lee
- Department of Food Science and Biotechnology, Gachon University, Seongnam, Gyeonggi 13120, Korea;
| | - Jeesu Kim
- Department of Cogno-Mechatronics Engineering, College of Nanoscience & Nanotechnology, Pusan National University, Busan 46241, Korea; (M.S.K.); (H.L.)
| | - Dong-Wook Han
- Department of Cogno-Mechatronics Engineering, College of Nanoscience & Nanotechnology, Pusan National University, Busan 46241, Korea; (M.S.K.); (H.L.)
| | - Ki Su Kim
- School of Chemical Engineering, College of Engineering, Pusan National University, Busan 46241, Korea;
| |
Collapse
|
6
|
Garrow AA, Andrews JPM, Gonzalez ZN, Corral CA, Portal C, Morgan TEF, Walton T, Wilson I, Newby DE, Lucatelli C, Tavares AAS. Preclinical dosimetry models and the prediction of clinical doses of novel positron emission tomography radiotracers. Sci Rep 2020; 10:15985. [PMID: 32994530 PMCID: PMC7525662 DOI: 10.1038/s41598-020-72830-w] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2020] [Accepted: 09/07/2020] [Indexed: 11/09/2022] Open
Abstract
Dosimetry models using preclinical positron emission tomography (PET) data are commonly employed to predict the clinical radiological safety of novel radiotracers. However, unbiased clinical safety profiling remains difficult during the translational exercise from preclinical research to first-in-human studies for novel PET radiotracers. In this study, we assessed PET dosimetry data of six 18F-labelled radiotracers using preclinical dosimetry models, different reconstruction methods and quantified the biases of these predictions relative to measured clinical doses to ease translation of new PET radiotracers to first-in-human studies. Whole-body PET images were taken from rats over 240 min after intravenous radiotracer bolus injection. Four existing and two novel PET radiotracers were investigated: [18F]FDG, [18F]AlF-NOTA-RGDfK, [18F]AlF-NOTA-octreotide ([18F]AlF-NOTA-OC), [18F]AlF-NOTA-NOC, [18F]ENC2015 and [18F]ENC2018. Filtered-back projection (FBP) and iterative methods were used for reconstruction of PET data. Predicted and true clinical absorbed doses for [18F]FDG and [18F]AlF-NOTA-OC were then used to quantify bias of preclinical model predictions versus clinical measurements. Our results show that most dosimetry models were biased in their predicted clinical dosimetry compared to empirical values. Therefore, normalization of rat:human organ sizes and correction for reconstruction method biases are required to achieve higher precision of dosimetry estimates.
Collapse
Affiliation(s)
- Adam A Garrow
- Preclinical PET-CT Facility, Edinburgh Imaging, Queen's Medical Research Institute, The University of Edinburgh, 47 Little France Crescent, Edinburgh, EH16 4TJ, UK
| | - Jack P M Andrews
- University/BHF Centre for Cardiovascular Science, Queen's Medical Research Institute, Edinburgh, EH16 4TJ, UK
| | - Zaniah N Gonzalez
- Preclinical PET-CT Facility, Edinburgh Imaging, Queen's Medical Research Institute, The University of Edinburgh, 47 Little France Crescent, Edinburgh, EH16 4TJ, UK.,University/BHF Centre for Cardiovascular Science, Queen's Medical Research Institute, Edinburgh, EH16 4TJ, UK
| | - Carlos A Corral
- Preclinical PET-CT Facility, Edinburgh Imaging, Queen's Medical Research Institute, The University of Edinburgh, 47 Little France Crescent, Edinburgh, EH16 4TJ, UK.,University/BHF Centre for Cardiovascular Science, Queen's Medical Research Institute, Edinburgh, EH16 4TJ, UK
| | - Christophe Portal
- Edinburgh Molecular Imaging (EMI), Nine Edinburgh Bioquarter, Edinburgh, EH16 4UX, UK
| | - Timaeus E F Morgan
- Preclinical PET-CT Facility, Edinburgh Imaging, Queen's Medical Research Institute, The University of Edinburgh, 47 Little France Crescent, Edinburgh, EH16 4TJ, UK.,University/BHF Centre for Cardiovascular Science, Queen's Medical Research Institute, Edinburgh, EH16 4TJ, UK
| | - Tashfeen Walton
- Preclinical PET-CT Facility, Edinburgh Imaging, Queen's Medical Research Institute, The University of Edinburgh, 47 Little France Crescent, Edinburgh, EH16 4TJ, UK.,University/BHF Centre for Cardiovascular Science, Queen's Medical Research Institute, Edinburgh, EH16 4TJ, UK
| | - Ian Wilson
- Edinburgh Molecular Imaging (EMI), Nine Edinburgh Bioquarter, Edinburgh, EH16 4UX, UK
| | - David E Newby
- Preclinical PET-CT Facility, Edinburgh Imaging, Queen's Medical Research Institute, The University of Edinburgh, 47 Little France Crescent, Edinburgh, EH16 4TJ, UK.,University/BHF Centre for Cardiovascular Science, Queen's Medical Research Institute, Edinburgh, EH16 4TJ, UK
| | - Christophe Lucatelli
- Preclinical PET-CT Facility, Edinburgh Imaging, Queen's Medical Research Institute, The University of Edinburgh, 47 Little France Crescent, Edinburgh, EH16 4TJ, UK
| | - Adriana A S Tavares
- Preclinical PET-CT Facility, Edinburgh Imaging, Queen's Medical Research Institute, The University of Edinburgh, 47 Little France Crescent, Edinburgh, EH16 4TJ, UK. .,University/BHF Centre for Cardiovascular Science, Queen's Medical Research Institute, Edinburgh, EH16 4TJ, UK.
| |
Collapse
|
7
|
Silva CC, Berdeguez MB, Barboza T, Souza SA, Braz D, Silva AX, Sa LV. Preclinical radiation internal dosimetry in the development of new radiopharmaceuticals using GATE Monte Carlo simulation. Radiat Phys Chem Oxf Engl 1993 2020. [DOI: 10.1016/j.radphyschem.2020.108879] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
8
|
Abstract
Molecular imaging enables both spatial and temporal understanding of the complex biologic systems underlying carcinogenesis and malignant spread. Single-photon emission tomography (SPECT) is a versatile nuclear imaging-based technique with ideal properties to study these processes in vivo in small animal models, as well as to identify potential drug candidates and characterize their antitumor action and potential adverse effects. Small animal SPECT and SPECT-CT (single-photon emission tomography combined with computer tomography) systems continue to evolve, as do the numerous SPECT radiopharmaceutical agents, allowing unprecedented sensitivity and quantitative molecular imaging capabilities. Several of these advances, their specific applications in oncology as well as new areas of exploration are highlighted in this chapter.
Collapse
Affiliation(s)
- Benjamin L Franc
- Department of Radiology, Stanford University School of Medicine, 300 Pasteur Drive, H2232, MC 5281, Stanford, CA, 94305-5105, USA.
| | - Youngho Seo
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, USA
| | - Robert Flavell
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, USA
| | - Carina Mari Aparici
- Department of Radiology, Stanford University School of Medicine, 300 Pasteur Drive, H2232, MC 5281, Stanford, CA, 94305-5105, USA
| |
Collapse
|
9
|
Montgomery DA, Martinez NE. Dosimetric modeling of Tc-99, Cs-137, Np-237, and U-238 in the grass species Andropogon Virginicus: Development and comparison of stylized, voxel, and hybrid phantom geometry. JOURNAL OF ENVIRONMENTAL RADIOACTIVITY 2020; 211:106075. [PMID: 31627053 DOI: 10.1016/j.jenvrad.2019.106075] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/05/2019] [Revised: 09/12/2019] [Accepted: 10/01/2019] [Indexed: 06/10/2023]
Abstract
This paper discusses the development, comparison, and application of three anatomically representative computational phantoms for the grass species Andropogon virginicus, an indigenous grass species in the Southeastern United States. Specifically, the phantoms developed in this work are: (1) a stylized phantom where plant organs (roots or shoots) are represented by simple geometric shapes, (2) a voxel phantom developed from micro-CT imagery of a plant specimen, and (3) a hybrid phantom resulting from the refinement of (2) by use of non-uniform rational basis spline (NURBS) surfaces. For each computational phantom, Monte Carlo dosimetric modeling was utilized to determine whole-organism and organ specific dose coefficients (DC) associated with external and internal exposure to 99Tc, 137Cs, 237Np, and 238U for A. virginicus. Model DCs were compared to each other and to current values for the ICRP reference wild grass in order to determine if noteworthy differences resulted from the utilization of more anatomically realistic phantom geometry. Modeled internal DCs were comparable with ICRP values. However, modeled external DCs were more variable with respect to ICRP values; this is proposed to be primarily due to differences in organism and source geometry definitions. Overall, the three anatomical phantoms were reasonably consistent. Some noticeable differences in internal DCs were observed between the stylized model and the voxel or hybrid models for external DCs for shoots and for cases of crossfire between plant organs. Additionally, uptake data from previous hydroponic (HP) experiments was applied in conjunction with hybrid model DCs to determine dose rates to the plant from individual radionuclides as an example of practical application. Although the models within are applied to a small-scale, hypothetical scenario as proof-of-principle, the potential, real-world utility of such complex dosimetric models for non-human biota is discussed, and a fit-for purpose approach for application of these models is proposed.
Collapse
Affiliation(s)
- Dawn A Montgomery
- Department of Environmental Engineering and Earth Sciences, Clemson University, Clemson, SC, USA; Center for Nuclear Environmental Engineering Sciences and Radioactive Waste Management (NEESRWM), Clemson University, Clemson, SC, USA.
| | - Nicole E Martinez
- Department of Environmental Engineering and Earth Sciences, Clemson University, Clemson, SC, USA; Center for Nuclear Environmental Engineering Sciences and Radioactive Waste Management (NEESRWM), Clemson University, Clemson, SC, USA
| |
Collapse
|
10
|
Xie T, Park JS, Zhuo W, Zaidi H. Development of a nonhuman primate computational phantom for radiation dosimetry. Med Phys 2019; 47:736-744. [DOI: 10.1002/mp.13936] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2019] [Revised: 11/01/2019] [Accepted: 11/13/2019] [Indexed: 01/27/2023] Open
Affiliation(s)
- Tianwu Xie
- Institute of Radiation Medicine Fudan University 2094 Xietu Road Shanghai 200032China
- Department of Medical Imaging and Information Sciences Geneva University Hospital Geneva Switzerland
| | - Jin Seo Park
- Department of Anatomy Dongguk University School of Medicine Gyeongju Korea
| | - Weihai Zhuo
- Institute of Radiation Medicine Fudan University 2094 Xietu Road Shanghai 200032China
| | - Habib Zaidi
- Department of Medical Imaging and Information Sciences Geneva University Hospital Geneva Switzerland
- Geneva Neuroscience Center Geneva University Geneva Switzerland
- Department of Nuclear Medicine and Molecular Imaging University of Groningen University Medical Center Groningen Groningen Netherlands
- Department of Nuclear Medicine University of Southern Denmark DK‐500Odense Denmark
| |
Collapse
|
11
|
Wang HY, Li CF, Yu C, Dong J, Zou Y, Nie BB, Li JK, Ma L, Peng RY. The specific absorption rate in different brain regions of rats exposed to electromagnetic plane waves. Sci Rep 2019; 9:13277. [PMID: 31527693 PMCID: PMC6746715 DOI: 10.1038/s41598-019-49719-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2019] [Accepted: 08/27/2019] [Indexed: 11/09/2022] Open
Abstract
Accurate dosimetry of a specific brain region in rats exposed to an electromagnetic field (EMF) is essential for studies focusing on dose-effect relationship of the region. However, only dosimetry of whole brain or whole body were evaluated in most of previous studies. In this study, a numerical voxel rat model with 10 segmented brain regions was constructed. Then, the effects of frequency, incidence direction, and E-polarization direction of plane wave EMF on brain region averaged specific absorption rate (BRSAR) of rats were investigated. At last, the reliability of using whole-body averaged SAR (WBDSAR) and whole-brain averaged SAR (WBRSAR) as estimations of BRSAR were also evaluated. Our results demonstrated that the BRSAR depended on the frequency, incidence direction, and E-polarization direction of the EMF. Besides, the largest deviation could be up to 13.1 dB between BRSAR and WBDSAR and 9.59 dB between BRSAR and WBRSAR. The results suggested that to establish an accurate dose-effect relationship, the variance of the BRSAR induced by alteration of frequency, incidence direction, and E-polarization direction of EMF should be avoided or carefully evaluated. Furthermore, the use of WBDSAR and WBRSAR as estimations of BRSAR should be restricted to certain conditions such that the deviations are not too large.
Collapse
Affiliation(s)
- Hao-Yu Wang
- Beijing Institute of Radiation Medicine, Beijing, 100850, China
| | - Chun-Fang Li
- Beijing Institute of Radiation Medicine, Beijing, 100850, China.,First Medical Center of PLA General Hospital, Beijing, 100853, China
| | - Chao Yu
- Beijing Institute of Radiation Medicine, Beijing, 100850, China
| | - Ji Dong
- Beijing Institute of Radiation Medicine, Beijing, 100850, China
| | - Yong Zou
- Beijing Institute of Radiation Medicine, Beijing, 100850, China
| | - Bin-Bin Nie
- Beijing Engineering Research Center of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, 100049, China
| | - Jia-Kai Li
- Hainan Hospital of PLA General Hospital, Sanya, 572013, Hainan, China
| | - Lin Ma
- First Medical Center of PLA General Hospital, Beijing, 100853, China
| | - Rui-Yun Peng
- Beijing Institute of Radiation Medicine, Beijing, 100850, China.
| |
Collapse
|