Wen N, Zhang Y, Zhang H, Zhang M, Zhou J, Liu Y, Liao C, Jia L, Zhang K, Chen J. A Dual-Energy Computed Tomography Guided Intelligent Radiation Therapy Platform. Int J Radiat Oncol Biol Phys 2025:S0360-3016(25)00085-9. [PMID: 39921109 DOI: 10.1016/j.ijrobp.2025.01.028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2024] [Revised: 01/17/2025] [Accepted: 01/25/2025] [Indexed: 02/10/2025]
Abstract
PURPOSE The integration of advanced imaging and artificial intelligence technologies in radiation therapy has revolutionized cancer treatment by enhancing precision and adaptability. This study introduces a novel dual-energy computed tomography (DECT) guided intelligent radiation therapy (DEIT) platform designed to streamline and optimize the radiation therapy process. The DEIT system combines DECT, a newly designed dual-layer multileaf collimator, deep learning algorithms for auto-segmentation, and automated planning and quality assurance capabilities. METHODS AND MATERIALS The DEIT system integrates an 80-slice computed tomography (CT) scanner with an 87 cm bore size, a linear accelerator delivering 4 photon and 5 electron energies, and a flat panel imager optimized for megavoltage (MV) cone beam CT acquisition. A comprehensive evaluation of the system's accuracy was conducted using end-to-end tests. Virtual monoenergetic CT images and electron density images of the DECT were generated and compared on both phantom and patient. The system's auto-segmentation algorithms were tested on 5 cases for each of the 99 organs at risk, and the automated optimization and planning capabilities were evaluated on clinical cases. RESULTS The DEIT system demonstrated systematic errors of less than 1 mm for target localization. DECT reconstruction showed electron density mapping deviations ranging from -0.052 to 0.001, with stable Hounsfield unit consistency across monoenergetic levels above 60 keV, except for high-Z materials at lower energies. Auto-segmentation achieved dice similarity coefficients above 0.9 for most organs with an inference time of less than 2 seconds. Dose-volume histogram comparisons showed improved dose conformity indices and reduced doses to critical structures in auto-plans compared to manual plans across various clinical cases. In addition, high gamma passing rates at 2%/2 mm in both 2-dimensional (above 97%) and 3-dimensional (above 99%) in vivo analyses further validate the accuracy and reliability of treatment plans. CONCLUSIONS The DEIT platform represents a viable solution for radiation treatment. The DEIT system uses artificial intelligence-driven automation, real-time adjustments, and CT imaging to enhance the radiation therapy process, improving efficiency and flexibility.
Collapse
Affiliation(s)
- Ning Wen
- Department of Radiology, Ruijin Hospital Shanghai Jiaotong University School of Medicine, Shanghai, China; The Global Institute of Future Technology, Shanghai Jiaotong University, Shanghai, China; The SJTU-Ruijin-UIH Institute for Medical Imaging Technology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China.
| | - Yibin Zhang
- The SJTU-Ruijin-UIH Institute for Medical Imaging Technology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China; Department of Radiation Oncology, Ruijin Hospital Shanghai Jiaotong University School of Medicine, Shanghai, China; Shanghai Key Laboratory of Proton Therapy, Shanghai, China
| | - Haoran Zhang
- Department of Radiology, Ruijin Hospital Shanghai Jiaotong University School of Medicine, Shanghai, China; The SJTU-Ruijin-UIH Institute for Medical Imaging Technology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China
| | - Maochen Zhang
- The SJTU-Ruijin-UIH Institute for Medical Imaging Technology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China; Department of Radiation Oncology, Ruijin Hospital Shanghai Jiaotong University School of Medicine, Shanghai, China; Shanghai Key Laboratory of Proton Therapy, Shanghai, China
| | - Jingjie Zhou
- Radiotherapy Business Unit, Shanghai United Imaging Healthcare Co. Ltd, Shanghai, China
| | - Yanfang Liu
- Radiotherapy Business Unit, Shanghai United Imaging Healthcare Co. Ltd, Shanghai, China
| | - Can Liao
- Radiotherapy Business Unit, Shanghai United Imaging Healthcare Co. Ltd, Shanghai, China
| | - Lecheng Jia
- Radiotherapy Laboratory, Shenzhen United Imaging Research Institute of Innovative Medical Equipment, Shenzhen, China
| | - Kang Zhang
- Radiotherapy Business Unit, Shanghai United Imaging Healthcare Co. Ltd, Shanghai, China
| | - Jiayi Chen
- The SJTU-Ruijin-UIH Institute for Medical Imaging Technology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China; Department of Radiation Oncology, Ruijin Hospital Shanghai Jiaotong University School of Medicine, Shanghai, China; Shanghai Key Laboratory of Proton Therapy, Shanghai, China.
| |
Collapse
|
2
|
Sánchez‐Rubio P, Rodríguez‐Romero R, Pinto‐Monedero M, Alejo‐Luque L, Martínez‐Ortega J. New findings on clinical experience on surface-guided radiotherapy for frameless non-coplanar stereotactic radiosurgery treatments. J Appl Clin Med Phys 2024; 25:e14510. [PMID: 39287562 PMCID: PMC11633809 DOI: 10.1002/acm2.14510] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2024] [Revised: 08/05/2024] [Accepted: 08/20/2024] [Indexed: 09/19/2024] Open
Abstract
PURPOSE The aim of this study was to assess the accuracy of a surface-guided radiotherapy (SGRT) system for setup and intra-fraction motion control in frameless non-coplanar stereotactic radiosurgery (fSRS) using actual patient data immobilized with two different types of open-faced masks and employing a novel SGRT systems settings. METHODS AND MATERIALS Forty-four SRS patients were immobilized with two types of open-faced masks. Sixty lesions were treated, involving the analysis of 68 cone-beam scans (CBCT), 157 megavoltage (MV) images, and 521 SGRT monitoring sessions. The average SGRT translations/rotations and 3D vectors (MAG-Trasl and MAG-Rot) were compared with CBCT or antero-posterior MV images for 0° table or non-coplanar beams, respectively. The intrafraction control was evaluated based on the average shifts obtained from each monitoring session. To assess the association between the SGRT system and the CBCT, the two types of masks and the 3D vectors, a generalized estimating equations (GEE) regression analysis was performed. The Wilcoxon singed-rank test for paired samples was performed to detect differences in couch rotation with longitudinal (LNG) and lateral (LAT) translations and/or yaw. RESULTS The average SGRT corrections were smaller than those detected by CBCT (≤0.5 mm and 0.1°), with largest differences in LNG and yaw. The GEE analysis indicated that the average MAG-Trasl, obtained by the SGRT system, was not statistically different (p = 0.09) for both mask types, while, the MAG-Rot was different (p = 0.01). For non-coplanar beams, the Wilcoxon singed-rank test demonstrated no significantly differences for the corrections (LNG, LAT, and yaw) for any table rotation except for LNG corrections at 65° (p = 0.04) and 75° (p = 0.03) table angle position; LAT shifts at 65° (p = 0.03) and 270° (p < 0.001) table angle position, and yaw rotation at 30° (p = 0.02) table angle position. The average intrafraction motion was < 0.1 mm and 0.1° for any table angle. CONCLUSION The SGRT system used, along with the novel workflow performed, can achieve the setup and intra-fraction motion control accuracy required to perform non-coplanar fSRS treatments. Both masks ensure the accuracy required for fSRS while providing a suitable surface for monitoring.
Collapse
Affiliation(s)
- Patricia Sánchez‐Rubio
- Medical Physics DepartmentHospital Universitario Puerta de Hierro MajadahondaMadridSpain
| | - Ruth Rodríguez‐Romero
- Medical Physics DepartmentHospital Universitario Puerta de Hierro MajadahondaMadridSpain
| | - María Pinto‐Monedero
- Medical Physics DepartmentHospital Universitario Puerta de Hierro MajadahondaMadridSpain
| | - Luis Alejo‐Luque
- Medical Physics DepartmentHospital Universitario Puerta de Hierro MajadahondaMadridSpain
| | - Jaime Martínez‐Ortega
- Medical Physics DepartmentHospital Universitario Puerta de Hierro MajadahondaMadridSpain
| |
Collapse
|
3
|
Gao J, Anand D. Off-iso Winston-Lutz test on seven linear accelerators. J Appl Clin Med Phys 2024; 25:e14470. [PMID: 39042435 PMCID: PMC11466459 DOI: 10.1002/acm2.14470] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2024] [Revised: 05/31/2024] [Accepted: 06/26/2024] [Indexed: 07/24/2024] Open
Abstract
PURPOSE The aim of this study is to find optimal gantry, collimator, and couch angles for performing single isocenter, multiple target stereotactic radiosurgery (SIMT-SRS). Nineteen angle sets were tested across seven linear accelerators for radiation-isocenter coincidence and off-isocenter coincidence. The off-isocenter Winston-Lutz test was performed to evaluate the accuracy of isocenter alignment for each angle set, and optimal angle sets as well as maximum off-isocenter distance to target for each angle set was determined. The influence of simulated patient weight on off-iso Winston-Lutz test accuracy was also inspected. METHOD The SNC MultiMet-WL phantom and MultiMet-WL QA Software v2.1 were used for the direct measurement and analysis of the off-iso Winston-Lutz test (also referred to as Winston-Lutz-Gao test). A two-step method was developed to ensure precise initial placement of the target. Nineteen beams were delivered at 6X energy and 2 × 2 cm field size to each of six targets on the MultiMet Cube with couch kicks at five cardinal angles (90°, 45°, 0°, 315°, and 270°). To reduce imaging uncertainty, only EPID was used in target alignment and test image acquisition. A total of 200 Ibs (90.7 kg) of weight was also used to mimic patient weight. All tests were performed on both the free table and the weighted table. RESULTS For two new TrueBeam machines, the maximum offset was within the 1 mm tolerance when the off-iso distance is less than 7 cm. Two older VitalBeam machines exhibited unfavorable gantry, couch, and collimator (GCC) angle sets: Linac No. 3 at (0,90,0), (0,270,0) and Linac No. 4 at (0,45,45) and (0,90,0). The C-Series Linacs failed in the majority of GCC angle sets, with Linac No. 5 exhibiting a maximum offset of 1.53 mm. Four of seven machines show a clear trend that offset increases with off-isocenter distance. Additionally, the IGRT table was less susceptible to the addition of simulated patient weight than the ExactCouch. CONCLUSION Among the seven linear accelerators addressed, newer model machines such as the Varian TrueBeam were more precise than older models, especially in comparison to the C-Series Linacs. The newer machines are more suitable for delivering SIMT-SRS procedures in all GCC angle sets, and the results indicate that newer TrueBeams are capable of performing SIMT-SRS procedures at all angle sets for targets of off-iso distances up to 7 cm. The trend that offset between the target center and radiation field center increases with off-iso distance, however, does not always hold true across machines. This may be comprised by the EPID's severe off-axis horn effect. Lastly, the IGRT couch was less susceptible to patient weight compared to ExactCouch in the off-isocenter Winston-Lutz test.
Collapse
Affiliation(s)
- Junfang Gao
- Radiotherapy Clinics of GeorgiaDecaturGeorgiaUSA
- Radiation oncology department, Texas OncologyHoustonTexasUSA
| | - David Anand
- Radiation oncology department, Texas OncologyHoustonTexasUSA
| |
Collapse
|
4
|
Peña-Pino I, Chen CC. Stereotactic Radiosurgery as Treatment for Brain Metastases: An Update. Asian J Neurosurg 2023; 18:246-257. [PMID: 37397044 PMCID: PMC10310446 DOI: 10.1055/s-0043-1769754] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/04/2023] Open
Abstract
Stereotactic radiosurgery (SRS) is a mainstay treatment option for brain metastasis (BM). While guidelines for SRS use have been outlined by professional societies, consideration of these guidelines should be weighed in the context of emerging literature, novel technology platforms, and contemporary treatment paradigms. Here, we review recent advances in prognostic scale development for SRS-treated BM patients and survival outcomes as a function of the number of BM and cumulative intracranial tumor volume. Focus is placed on the role of stereotactic laser thermal ablation in the management of BM that recur after SRS and the management of radiation necrosis. Neoadjuvant SRS prior to surgical resection as a means of minimizing leptomeningeal spread is also discussed.
Collapse
Affiliation(s)
- Isabela Peña-Pino
- Department of Biomedical Engineering, University of Minnesota, Minneapolis, Minnesota, United States
| | - Clark C. Chen
- Department of Neurosurgery, University of Minnesota, Minneapolis, Minnesota, United States
| |
Collapse
|
5
|
Pokhrel D, Mallory R, Bernard ME. The spatial accuracy of ring-mounted halcyon linac versus C-arm TrueBeam linac for single-isocenter/multi-target SBRT treatment. Med Dosim 2023:S0958-3947(23)00026-2. [PMID: 37059628 DOI: 10.1016/j.meddos.2023.03.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Revised: 02/01/2023] [Accepted: 03/14/2023] [Indexed: 04/16/2023]
Abstract
Stereotactic body radiotherapy (SBRT) treatment of oligometastatic lesions via single-isocenter/multi-target (SIMT) plan is more efficient than using multi-isocenter/multitarget SBRT. This study quantifies the spatial positioning accuracy of 2 commercially available LINAC systems for SIMT treatment pertaining to the potential amplification of error as a function of the target's distance-to-isocenter. We compare the Ring-Gantry Halcyon LINAC equipped with the fast iterative conebeam-CT (iCBCT) for image-guided SIMT treatment, and the SBRT-dedicated C-Arm TrueBeam with standard pretreatment CBCT imaging. For both systems, Sun Nuclear's MultiMet Winston-Lutz Cube phantom with 6 metallic BBs distributed at different planes up to 7 cm away from the isocenter was used. The phantom was aligned and imaged via CBCT, and then couch corrections were applied. To treat all 6 BBs, an Eclipse 10-field 3D-conformal Field-in-Field (2×2 cm2 MLC field to each BB) plan for varying gantry, collimator, and couch (TrueBeam only) positions was developed for both machines with 6MV-FFF beam. The plan was delivered through ARIA once a week. The EPID images were analyzed via Sun Nuclear's software for spatial positioning accuracy. On TrueBeam, the treatment plan was delivered twice: once with 3DoF translational corrections and once with PerfectPitch 6DoF couch corrections. The average 3D spatial positioning accuracy was 0.55 ± 0.30 mm, 0.54 ± 0.24 mm, and 0.56 ± 0.28 mm at isocenter, and 0.59 ± 0.30 mm, 0.69 ± 0.30 mm, and 0.70 ± 0.35 mm at 7 cm distance-to-isocenter for Halcyon, TrueBeam 3DoF, and TrueBeam 6DoF, respectively. This suggests there are no clinically significant deviations of spatial uncertainty between the platforms with the distance-to-isocenter. On both platforms, our weekly independent measurements demonstrated the reproducibility for less than 1.0 mm positional accuracy of off-axis targets up to 7 cm from the isocenter. Due to this, no additional PTV-margin is suggested for lesions within 7 cm of isocenter. This study confirms that Halcyon can deliver similar positional accuracy to SBRT-dedicated TrueBeam to off-axis targets up to 7 cm from isocenter. These results further benchmark the spatial uncertainty of our extensively used SBRT-dedicated TrueBeam LINAC for SIMT SBRT treatments.
Collapse
Affiliation(s)
- Damodar Pokhrel
- Department of Radiation Medicine, University of Kentucky, Lexington, KY 40536, USA.
| | - Richard Mallory
- Department of Radiation Medicine, University of Kentucky, Lexington, KY 40536, USA
| | - Mark E Bernard
- Department of Radiation Medicine, University of Kentucky, Lexington, KY 40536, USA
| |
Collapse
|
6
|
Da Silva Mendes V, Reiner M, Huang L, Reitz D, Straub K, Corradini S, Niyazi M, Belka C, Kurz C, Landry G, Freislederer P. ExacTrac Dynamic workflow evaluation: Combined surface optical/thermal imaging and X-ray positioning. J Appl Clin Med Phys 2022; 23:e13754. [PMID: 36001389 DOI: 10.1002/acm2.13754] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2021] [Revised: 07/07/2022] [Accepted: 07/19/2022] [Indexed: 11/09/2022] Open
Abstract
In modern radiotherapy (RT), especially for stereotactic radiotherapy or stereotactic radiosurgery treatments, image guidance is essential. Recently, the ExacTrac Dynamic (EXTD) system, a new combined surface-guided RT and image-guided RT (IGRT) system for patient positioning, monitoring, and tumor targeting, was introduced in clinical practice. The purpose of this study was to provide more information about the geometric accuracy of EXTD and its workflow in a clinical environment. The surface optical/thermal- and the stereoscopic X-ray imaging positioning systems of EXTD was evaluated and compared to cone-beam computed tomography (CBCT). Additionally, the congruence with the radiation isocenter was tested. A Winston Lutz test was executed several times over 1 year, and repeated end-to-end positioning tests were performed. The magnitude of the displacements between all systems, CBCT, stereoscopic X-ray, optical-surface imaging, and MV portal imaging was within the submillimeter range, suggesting that the image guidance provided by EXTD is accurate at any couch angle. Additionally, results from the evaluation of 14 patients with intracranial tumors treated with open-face masks are reported, and limited differences with a maximum of 0.02 mm between optical/thermal- and stereoscopic X-ray imaging were found. As the optical/thermal positioning system showed a comparable accuracy to other IGRT systems, and due to its constant monitoring capability, it can be an efficient tool for detecting intra-fractional motion and for real-time tracking of the surface position during RT.
Collapse
Affiliation(s)
| | - Michael Reiner
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany
| | - Lili Huang
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany
| | - Daniel Reitz
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany
| | - Katrin Straub
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany
| | - Stefanie Corradini
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany
| | - Maximilian Niyazi
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany
| | - Claus Belka
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany.,German Cancer Consortium (DKTK), Partner Site Munich, Munich, Germany
| | - Christopher Kurz
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany
| | - Guillaume Landry
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany
| | - Philipp Freislederer
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany
| |
Collapse
|
7
|
Lawler G. A review of surface guidance in extracranial stereotactic body radiotherapy (SBRT/SABR) for set-up and intra-fraction motion management. Tech Innov Patient Support Radiat Oncol 2022; 21:23-26. [PMID: 35079644 PMCID: PMC8777133 DOI: 10.1016/j.tipsro.2022.01.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Revised: 12/20/2021] [Accepted: 01/06/2022] [Indexed: 12/25/2022] Open
Abstract
Introduction Surface guidance (SG) radiotherapy (RT) is now used by many radiotherapy departments globally and has expanded in popularity over the last number of years. A number of commercial systems are available. SG has routinely been used and is well established for cranial stereotactic radiosurgery (SRS) patient set ups and intra-fraction motion monitoring. However, data is limited in relation to its clinical use for extracranial stereotactic body radiotherapy (SBRT), particularly for targets which are impacted by respiratory motion such as the lung and liver. Objective & Information Source A review of available literature was carried out on 24th October 2021 to assess the clinical feasibility and use of SG in SBRT via PubMed. Methods Eligibility Criteria The search criteria involved identifying articles where SG is used in extracranial SBRT. Risk of Bias To eliminate the risk of bias, any particular commercial system was not the focus of the review and not included in the search criteria. Numerous clinical terms for similar things were used to reduce the risk of missing papers e.g. SBRT and SABR. Search Criteria The PRISMA checklist was used. Searching for “surface guidance and radiotherapy” yielded 3271 results, where as “SGRT” alone returned 72 results, when the search term was narrowed down using different iterations of SG and SBRT, only 6 results were available. Of these, 4 had reviewed clinical data in relation to SG and SBRT for patient set up and intra-fraction motion monitoring. Results The 4 studies indicate positive results for using SG with sufficient image guidance (IG) for both patient set up and intra-fraction monitoring during SBRT. This was observed both in free breathing and in patients with respiratory motion management being employed such as deep inspiration breath-hold (DIBH) techniques. All used multiple IGRT solutions to verify localisation pre-treatment in conjunction with SG. Limitations The number of studies available which report using SG in SBRT is extremely limited. All centres had also installed SG systems therefore this could result in an unconditional bias in using the system positively. Conclusion SG can be used for SBRT set-ups and intra-fraction motion monitoring once sufficient IG is used to verify target localisation for treatment.
Collapse
|
8
|
Al-Hallaq HA, Cerviño L, Gutierrez AN, Havnen-Smith A, Higgins SA, Kügele M, Padilla L, Pawlicki T, Remmes N, Smith K, Tang X, Tomé WA. AAPM task group report 302: Surface guided radiotherapy. Med Phys 2022; 49:e82-e112. [PMID: 35179229 PMCID: PMC9314008 DOI: 10.1002/mp.15532] [Citation(s) in RCA: 99] [Impact Index Per Article: 33.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2021] [Revised: 12/26/2021] [Accepted: 02/05/2022] [Indexed: 11/06/2022] Open
Abstract
The clinical use of surface imaging has increased dramatically with demonstrated utility for initial patient positioning, real-time motion monitoring, and beam gating in a variety of anatomical sites. The Therapy Physics Subcommittee and the Imaging for Treatment Verification Working Group of the American Association of Physicists in Medicine commissioned Task Group 302 to review the current clinical uses of surface imaging and emerging clinical applications. The specific charge of this task group was to provide technical guidelines for clinical indications of use for general positioning, breast deep-inspiration breath-hold (DIBH) treatment, and frameless stereotactic radiosurgery (SRS). Additionally, the task group was charged with providing commissioning and on-going quality assurance (QA) requirements for surface guided radiation therapy (SGRT) as part of a comprehensive QA program including risk assessment. Workflow considerations for other anatomic sites and for computed tomography (CT) simulation, including motion management are also discussed. Finally, developing clinical applications such as stereotactic body radiotherapy (SBRT) or proton radiotherapy are presented. The recommendations made in this report, which are summarized at the end of the report, are applicable to all video-based SGRT systems available at the time of writing. Review current use of non-ionizing surface imaging functionality and commercially available systems. Summarize commissioning and on-going quality assurance (QA) requirements of surface image-guided systems, including implementation of risk or hazard assessment of surface guided radiotherapy as a part of a total quality management program (e.g., TG-100). Provide clinically relevant technical guidelines that include recommendations for the use of SGRT for general patient positioning, breast DIBH, and frameless brain SRS, including potential pitfalls to avoid when implementing this technology. Discuss emerging clinical applications of SGRT and associated QA implications based on evaluation of technology and risk assessment. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Hania A Al-Hallaq
- Department of Radiation & Cellular Oncology, University of Chicago, Chicago, IL, 60637, USA
| | - Laura Cerviño
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA
| | - Alonso N Gutierrez
- Department of Radiation Oncology, Miami Cancer Institute, Miami, FL, 33173, USA
| | | | - Susan A Higgins
- Department of Therapeutic Radiology, Yale University, New Haven, CT, 06520, USA
| | - Malin Kügele
- Department of Hematology, Oncology and Radiation Physics, Skåne University, Lund, 221 00, Sweden.,Medical Radiation Physics, Department of Clinical Sciences, Lund University, Lund, 221 00, Sweden
| | - Laura Padilla
- Department of Radiation Medicine & Applied Sciences, University of California, San Diego, La Jolla, CA, 92093, USA
| | - Todd Pawlicki
- Department of Radiation Medicine & Applied Sciences, University of California, San Diego, La Jolla, CA, 92093, USA
| | - Nicholas Remmes
- Department of Radiation Oncology, Mayo Clinic, Rochester, MN, 55905, USA
| | - Koren Smith
- IROC Rhode Island, University of Massachusetts Chan Medical School, Lincoln, RI, 02865, USA
| | | | - Wolfgang A Tomé
- Department of Radiation Oncology and Department of Neurology, Montefiore Medical Center and Albert Einstein College of Medicine, Bronx, NY, 10461, USA
| |
Collapse
|
9
|
Veselsky T, Syruckova T, Kindlova A, Osmancikova P. Pituitary adenoma treatment plan quality comparison between linear accelerator volumetric modulated arc therapy and Leksell Gamma Knife® radiosurgery. Med Dosim 2021; 46:440-448. [PMID: 34312022 DOI: 10.1016/j.meddos.2021.06.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2020] [Revised: 04/16/2021] [Accepted: 06/14/2021] [Indexed: 11/26/2022]
Abstract
The aim of this study was to compare radiosurgical treatment plan quality of a linear accelerator with Leksell Gamma Knife (LGK) for pituitary adenoma irradiation. Thirty pituitary adenoma patients were evaluated in this study. Treatment plans were prepared on LGK and stereotactic linear accelerator Varian TrueBeam STx. Volumetric Modulated Arc Therapy (VMAT) plans (21 plans with 2 coplanar arcs and 9 plans with 4 non-coplanar arcs) were calculated for linear accelerator. All the plans were evaluated in terms of conformity, selectivity, gradient index and organ at risk (OAR) sparing. VMAT produced dosimetrically comparable treatment plans to LGK regarding conformity and selectivity (New Conformity Index (NCI): 1.76 ± 0.65 for 4 arc VMAT, 2.33 ± 1,16 for 2 arc VMAT and 1.96 ± 0.71 for LGK; Selectivity Index (SI): 0.63 ± 0.16 for 4 arc VMAT, 0.51 ± 0.16 for 2 arc VMAT and 0.58 ± 0.17 for LGK). Gradient index (GI) was superior for LGK plans (GI: 2.74 ± 0.20 for LGK and 5.28 ± 2.29 for 4 arc VMAT). OAR sparing for optics, brainstem, and hypophysis was similar for both modalities while target volume coverage was maintained the same. Finally, treatment time resulted in favor of VMAT plans (in this study VMAT plans were almost 5 times faster than LGK treatment regarding beam on time). According to the results of this study stereotactic linear accelerator with VMAT treatment could be used as a reasonable alternative to LGK for pituitary adenoma radiosurgery but only if the same head fixation method accuracy and target volume delineation are maintained for both modalities.
Collapse
Affiliation(s)
- T Veselsky
- Motol University Hospital, Oncology Clinic, Prague 5, Czech Republic; Military University Hospital, Department of Radiation Therapy, Prague 6, Czech Republic; Na Homolce Hospital, Medical Physics Department, Prague 5, Czech Republic.
| | - T Syruckova
- Czech Technical University in Prague, Faculty of Biomedical Engineering, Kladno, Czech Republic
| | - A Kindlova
- Motol University Hospital, Oncology Clinic, Prague 5, Czech Republic
| | - P Osmancikova
- Motol University Hospital, Oncology Clinic, Prague 5, Czech Republic; Czech Technical University in Prague, Faculty of Nuclear Sciences and Physical Engineering, Department of Dosimetry and Application of Ionizing Radiation, Prague 110 00, Czech Republic
| |
Collapse
|
10
|
Bossart E, Mellon EA, Monterroso I, Elsayyad N, Diwanji T, Samuels S, Dogan N. Assessment of single isocenter linear accelerator radiosurgery for metastases and base of skull lesions. Phys Med 2020; 81:1-8. [PMID: 33278764 DOI: 10.1016/j.ejmp.2020.11.011] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/12/2020] [Revised: 08/22/2020] [Accepted: 11/07/2020] [Indexed: 10/22/2022] Open
Abstract
BACKGROUND Newer technology for stereotactic radiosurgery (SRS) should be assessed for different multi-leaf collimators (MLC). OBJECTIVE Assess plan quality of an automated, frameless, linear accelerator based (linac) planning and delivery system (HyperArc) for SRS using both standard MLC (SMLC) and high definition MLC (HDMLC) compared to a cobalt-60 based SRS system (Gamma Knife, GK). METHODS We re-planned twenty GK Perfexion-treated SRS patients (27 lesions) for HyperArc using SMLC and HDMLC. We assessed plan quality using the following metrics: gradient index (GI), Paddick and RTOG conformity indices (CIPaddick, CIRTOG), volume receiving half of prescription isodose (PIVhalf) and maximum dose to 0.03 cc for brainstem, optic chiasm and optic nerves, and V12Gy for brain-GTV. RESULTS Linac plans had better conformity with HDMLC being most conformal. GK exhibited better GI. PIVhalf demonstrated no statistically significant difference between HDMLC and GK, and SMLC was nominally worse than GK. Mean PIVhalf was generally 0.85 cc larger for SMLC than HDMLC. For TV > 1.0 cc, the relative differences in CIRTOG, GI, and PIVhalf for SMLC vs. HDMLC were less than 21%. For TV less than < 1.0 cc, there were more obvious relative differences for SMLC vs. HDMLC in CIRTOG (mean 146%, max 700%), GI (mean 49%, max 162%), and PIVhalf (mean 77%, max 522%). Organ at risk doses were met in all plans. CONCLUSIONS New linac-based plans positively compare to GK plans overall. HDMLC should be strongly considered for treatment of lesions < 1.0 cc given the significant improvements in conformity and PIVhalf over SMLC.
Collapse
Affiliation(s)
- Elizabeth Bossart
- Department of Radiation Oncology, Sylvester Comprehensive Cancer Center, University of Miami Miller School of Medicine, Miami, FL, USA.
| | - Eric A Mellon
- Department of Radiation Oncology, Sylvester Comprehensive Cancer Center, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Irene Monterroso
- Department of Radiation Oncology, Sylvester Comprehensive Cancer Center, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Nagy Elsayyad
- Department of Radiation Oncology, Sylvester Comprehensive Cancer Center, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Tejan Diwanji
- Department of Radiation Oncology, Sylvester Comprehensive Cancer Center, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Stuart Samuels
- Department of Radiation Oncology, Sylvester Comprehensive Cancer Center, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Nesrin Dogan
- Department of Radiation Oncology, Sylvester Comprehensive Cancer Center, University of Miami Miller School of Medicine, Miami, FL, USA
| |
Collapse
|
11
|
Freislederer P, Kügele M, Öllers M, Swinnen A, Sauer TO, Bert C, Giantsoudi D, Corradini S, Batista V. Recent advanced in Surface Guided Radiation Therapy. Radiat Oncol 2020; 15:187. [PMID: 32736570 PMCID: PMC7393906 DOI: 10.1186/s13014-020-01629-w] [Citation(s) in RCA: 78] [Impact Index Per Article: 15.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2020] [Accepted: 07/21/2020] [Indexed: 01/27/2023] Open
Abstract
The growing acceptance and recognition of Surface Guided Radiation Therapy (SGRT) as a promising imaging technique has supported its recent spread in a large number of radiation oncology facilities. Although this technology is not new, many aspects of it have only recently been exploited. This review focuses on the latest SGRT developments, both in the field of general clinical applications and special techniques.SGRT has a wide range of applications, including patient positioning with real-time feedback, patient monitoring throughout the treatment fraction, and motion management (as beam-gating in free-breathing or deep-inspiration breath-hold). Special radiotherapy modalities such as accelerated partial breast irradiation, particle radiotherapy, and pediatrics are the most recent SGRT developments.The fact that SGRT is nowadays used at various body sites has resulted in the need to adapt SGRT workflows to each body site. Current SGRT applications range from traditional breast irradiation, to thoracic, abdominal, or pelvic tumor sites, and include intracranial localizations.Following the latest SGRT applications and their specifications/requirements, a stricter quality assurance program needs to be ensured. Recent publications highlight the need to adapt quality assurance to the radiotherapy equipment type, SGRT technology, anatomic treatment sites, and clinical workflows, which results in a complex and extensive set of tests.Moreover, this review gives an outlook on the leading research trends. In particular, the potential to use deformable surfaces as motion surrogates, to use SGRT to detect anatomical variations along the treatment course, and to help in the establishment of personalized patient treatment (optimized margins and motion management strategies) are increasingly important research topics. SGRT is also emerging in the field of patient safety and integrates measures to reduce common radiotherapeutic risk events (e.g. facial and treatment accessories recognition).This review covers the latest clinical practices of SGRT and provides an outlook on potential applications of this imaging technique. It is intended to provide guidance for new users during the implementation, while triggering experienced users to further explore SGRT applications.
Collapse
Affiliation(s)
- P. Freislederer
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany
| | - M. Kügele
- Department of Hematology, Oncology and Radiation Physics, Skåne University Hospital, Lund, Sweden
- Medical Radiation Physics, Department of Clinical Sciences, Lund University, Lund, Sweden
| | - M. Öllers
- Maastricht Radiation Oncology (MAASTRO), Maastricht, the Netherlands
| | - A. Swinnen
- Maastricht Radiation Oncology (MAASTRO), Maastricht, the Netherlands
| | - T.-O. Sauer
- Department of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - C. Bert
- Department of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - D. Giantsoudi
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, USA
| | - S. Corradini
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany
| | - V. Batista
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany
- National Center for Tumor diseases (NCT), Heidelberg, Germany
| |
Collapse
|
12
|
Capaldi DPI, Skinner LB, Dubrowski P, Yu AS. An integrated quality assurance phantom for frameless single-isocenter multitarget stereotactic radiosurgery. ACTA ACUST UNITED AC 2020; 65:115006. [DOI: 10.1088/1361-6560/ab8534] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
13
|
Schmitt D, Blanck O, Gauer T, Fix MK, Brunner TB, Fleckenstein J, Loutfi-Krauss B, Manser P, Werner R, Wilhelm ML, Baus WW, Moustakis C. Technological quality requirements for stereotactic radiotherapy : Expert review group consensus from the DGMP Working Group for Physics and Technology in Stereotactic Radiotherapy. Strahlenther Onkol 2020; 196:421-443. [PMID: 32211939 PMCID: PMC7182540 DOI: 10.1007/s00066-020-01583-2] [Citation(s) in RCA: 66] [Impact Index Per Article: 13.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2020] [Accepted: 01/13/2020] [Indexed: 12/25/2022]
Abstract
This review details and discusses the technological quality requirements to ensure the desired quality for stereotactic radiotherapy using photon external beam radiotherapy as defined by the DEGRO Working Group Radiosurgery and Stereotactic Radiotherapy and the DGMP Working Group for Physics and Technology in Stereotactic Radiotherapy. The covered aspects of this review are 1) imaging for target volume definition, 2) patient positioning and target volume localization, 3) motion management, 4) collimation of the irradiation and beam directions, 5) dose calculation, 6) treatment unit accuracy, and 7) dedicated quality assurance measures. For each part, an expert review for current state-of-the-art techniques and their particular technological quality requirement to reach the necessary accuracy for stereotactic radiotherapy divided into intracranial stereotactic radiosurgery in one single fraction (SRS), intracranial fractionated stereotactic radiotherapy (FSRT), and extracranial stereotactic body radiotherapy (SBRT) is presented. All recommendations and suggestions for all mentioned aspects of stereotactic radiotherapy are formulated and related uncertainties and potential sources of error discussed. Additionally, further research and development needs in terms of insufficient data and unsolved problems for stereotactic radiotherapy are identified, which will serve as a basis for the future assignments of the DGMP Working Group for Physics and Technology in Stereotactic Radiotherapy. The review was group peer-reviewed, and consensus was obtained through multiple working group meetings.
Collapse
Affiliation(s)
- Daniela Schmitt
- Klinik für Radioonkologie und Strahlentherapie, National Center for Radiation Research in Oncology (NCRO), Heidelberger Institut für Radioonkologie (HIRO), Universitätsklinikum Heidelberg, Heidelberg, Germany.
| | - Oliver Blanck
- Klinik für Strahlentherapie, Universitätsklinikum Schleswig-Holstein, Kiel, Germany
| | - Tobias Gauer
- Klinik für Strahlentherapie und Radioonkologie, Universitätsklinikum Hamburg-Eppendorf, Hamburg, Germany
| | - Michael K Fix
- Abteilung für Medizinische Strahlenphysik und Universitätsklinik für Radio-Onkologie, Inselspital-Universitätsspital Bern, Universität Bern, Bern, Switzerland
| | - Thomas B Brunner
- Universitätsklinik für Strahlentherapie, Universitätsklinikum Magdeburg, Magdeburg, Germany
| | - Jens Fleckenstein
- Klinik für Strahlentherapie und Radioonkologie, Universitätsmedizin Mannheim, Universität Heidelberg, Mannheim, Germany
| | - Britta Loutfi-Krauss
- Klinik für Strahlentherapie und Onkologie, Universitätsklinikum Frankfurt, Frankfurt am Main, Germany
| | - Peter Manser
- Abteilung für Medizinische Strahlenphysik und Universitätsklinik für Radio-Onkologie, Inselspital-Universitätsspital Bern, Universität Bern, Bern, Switzerland
| | - Rene Werner
- Institut für Computational Neuroscience, Universitätsklinikum Hamburg-Eppendorf, Hamburg, Germany
| | - Maria-Lisa Wilhelm
- Klinik für Strahlentherapie, Universitätsmedizin Rostock, Rostock, Germany
| | - Wolfgang W Baus
- Klinik für Radioonkologie, CyberKnife- und Strahlentherapie, Universitätsklinikum Köln, Cologne, Germany
| | - Christos Moustakis
- Klinik für Strahlentherapie-Radioonkologie, Universitätsklinikum Münster, Münster, Germany
| |
Collapse
|
14
|
Swinnen ACC, Öllers MC, Loon Ong C, Verhaegen F. The potential of an optical surface tracking system in non-coplanar single isocenter treatments of multiple brain metastases. J Appl Clin Med Phys 2020; 21:63-72. [PMID: 32237274 PMCID: PMC7324699 DOI: 10.1002/acm2.12866] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2019] [Revised: 01/23/2020] [Accepted: 02/24/2020] [Indexed: 12/25/2022] Open
Abstract
To evaluate the accuracy of a commercial optical surface tracking (OST) system and to demonstrate how it can be implemented to monitor patient positioning during non‐coplanar single isocenter stereotactic treatments of brain metastases. A 3‐camera OST system was used (Catalyst HD™, C‐RAD) on a TruebeamSTx with a 6DoF couch. The setup accuracy and agreement between the OST system, and CBCT and kV‐MV imaging at couch angles 0° and 270°, respectively, were examined. Film measurements at 3 depths in the Rando‐Alderson phantom were performed using a single isocenter non‐coplanar VMAT plan containing 4 brain lesions. Setup of the phantom was performed with CBCT at couch 0° and subsequently monitored by OST at other couch angles. Setup data for 7 volunteers were collected to evaluate the accuracy and reproducibility of the OST system at couch angles 0°, 45°, 90°, 315°, and 270°. These results were also correlated to the couch rotation offsets obtained by a Winston‐Lutz (WL) test. The Rando‐Alderson phantom, as well as volunteers, were fixated using open face masks (Orfit). For repeated tests with the Rando‐Alderson phantom, deviations between rotational and translational isocenter corrections for CBCT and OST systems are always within 0.2° (pitch, roll, yaw), and 0.1mm and 0.5mm (longitudinal, lateral, vertical) for couch positions 0° and 270°, respectively. Dose deviations between the film and TPS doses in the center of the 4 lesions were −1.2%, −0.1%, −0.0%, and −1.9%. Local gamma evaluation criteria of 2%/2 mm and 3%/1 mm yielded pass rates of 99.2%, 99.2%, 98.6%, 89.9% and 98.8%, 97.5%, 81.7%, 78.1% for the 4 lesions. Regarding the volunteers, the mean translational and rotational isocenter shift values were (0.24 ± 0.09) mm and (0.15 ± 0.07) degrees. Largest isocenter shifts were found for couch angles 45˚ and 90˚, confirmed by WL couch rotation offsets. Patient monitoring during non‐coplanar VMAT treatments of brain metastases is feasible with submillimeter accuracy.
Collapse
Affiliation(s)
| | | | - Chin Loon Ong
- Department of Radiation Oncology, HagaZiekenhuis, Den Haag, the Netherlands
| | | |
Collapse
|
15
|
Heinzerling JH, Hampton CJ, Robinson M, Bright M, Moeller BJ, Ruiz J, Prabhu R, Burri SH, Foster RD. Use of surface-guided radiation therapy in combination with IGRT for setup and intrafraction motion monitoring during stereotactic body radiation therapy treatments of the lung and abdomen. J Appl Clin Med Phys 2020; 21:48-55. [PMID: 32196944 PMCID: PMC7286017 DOI: 10.1002/acm2.12852] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2019] [Revised: 01/08/2020] [Accepted: 02/16/2020] [Indexed: 12/24/2022] Open
Abstract
Background and purpose Multiple techniques can be used to assist with more accurate patient setup and monitoring during Stereotactic body radiation therapy (SBRT) treatment. This study analyzes the accuracy of 3D surface mapping with Surface‐guided radiation therapy (SGRT) in detecting interfraction setup error and intrafraction motion during SBRT treatments of the lung and abdomen. Materials and Methods Seventy‐one patients with 85 malignant thoracic or abdominal tumors treated with SBRT were analyzed. For initial patient setup, an alternating scheme of kV/kV imaging or SGRT was followed by cone beam computed tomography (CBCT) for more accurate tumor volumetric localization. The CBCT six degree shifts after initial setup with each method were recorded to assess interfraction setup error. Patients were then monitored continuously with SGRT during treatment. If an intrafractional shift in any direction >2 mm for longer than 2 sec was detected by SGRT, then CBCT was repeated and the recorded deltas were compared to those detected by SGRT. Results Interfractional shifts after SGRT setup and CBCT were small in all directions with mean values of <5 mm and < 0.5 degrees in all directions. Additionally, 25 patients had detected intrafraction motion by SGRT during a total of 34 fractions. This resulted in 25 (73.5%) additional shifts of at least 2 mm on subsequent CBCT. When comparing the average vector detected shift by SGRT to the resulting vector shift on subsequent CBCT, no significant difference was found between the two. Conclusions Surface‐guided radiation therapy provides initial setup within 5 mm for patients treated with SBRT and can be used in place of skin marks or planar kV imaging prior to CBCT. In addition, continuous monitoring with SGRT during treatment was valuable in detecting potentially clinically meaningful intrafraction motion and was comparable in magnitude to shifts from additional CBCT scans. PTV margin reduction may be feasible for SBRT in the lung and abdomen when using SGRT for continuous patient monitoring during treatment.
Collapse
Affiliation(s)
- John H Heinzerling
- Levine Cancer Institute, Southeast Radiation Oncology Group, Atrium Health, Charlotte, NC, USA
| | - Carnell J Hampton
- Levine Cancer Institute, Department of Radiation Oncology, Atrium Health, Charlotte, NC, USA
| | - Myra Robinson
- Levine Cancer Institute, Department of Biostatistics, Atrium Health, Charlotte, NC, USA
| | - Megan Bright
- Levine Cancer Institute, Department of Radiation Oncology, Atrium Health, Charlotte, NC, USA
| | - Benjamin J Moeller
- Levine Cancer Institute, Southeast Radiation Oncology Group, Atrium Health, Charlotte, NC, USA
| | - Justin Ruiz
- Levine Cancer Institute, Department of Radiation Oncology, Atrium Health, Charlotte, NC, USA
| | - Roshan Prabhu
- Levine Cancer Institute, Southeast Radiation Oncology Group, Atrium Health, Charlotte, NC, USA
| | - Stuart H Burri
- Levine Cancer Institute, Southeast Radiation Oncology Group, Atrium Health, Charlotte, NC, USA
| | - Ryan D Foster
- Levine Cancer Institute, Department of Radiation Oncology, Atrium Health, Charlotte, NC, USA
| |
Collapse
|
16
|
Barfield G, Burton EW, Stoddart J, Metwaly M, Cawley MG. Quality assurance of gating response times for surface guided motion management treatment delivery using an electronic portal imaging detector. Phys Med Biol 2019; 64:125023. [PMID: 31071694 DOI: 10.1088/1361-6560/ab205a] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Gating response times of monitoring system/LINAC combinations for gated radiotherapy treatments are notoriously difficult to measure. This difficulty may reflect why the incorporation of gating response times is not thoroughly considered when creating treatment margins for gated radiotherapy treatments, however ignoring the effect of gating response time could lead to significant treatment inaccuracies. This study shows a methodology which measured gating response times for AlignRT/Varian Truebeam combination which appears to be applicable to any surface guided monitoring/Linac combination as well as those combinations which incorporate extended lag times (>200 ms). Beam on lag time appears to be measurably greater than beam off lag time. Although these gating response times are slower than other gating systems on the market, the advantages surface guided radiotherapy (SGRT) could potentially provide for treatment accuracy is discussed as well as demonstrating the lack of guidance regarding SGRT with respect to gated treatments.
Collapse
Affiliation(s)
- Gary Barfield
- Department of Radiotherapy Physics, United Lincolnshire Hospitals NHS Trust, Lincoln, United Kingdom. Author to whom any correspondence should be addressed
| | | | | | | | | |
Collapse
|
17
|
Covington EL, Fiveash JB, Wu X, Brezovich I, Willey CD, Riley K, Popple RA. Optical surface guidance for submillimeter monitoring of patient position during frameless stereotactic radiotherapy. J Appl Clin Med Phys 2019; 20:91-98. [PMID: 31095866 PMCID: PMC6560239 DOI: 10.1002/acm2.12611] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2018] [Revised: 04/10/2019] [Accepted: 04/18/2019] [Indexed: 11/12/2022] Open
Abstract
PURPOSE To evaluate the accuracy of monitoring intrafraction motion during stereotactic radiotherapy with the optical surface monitoring system. Prior studies showing a false increase in the magnitude of translational offsets at non-coplanar couch positions prompted the vendor to implement software changes. This study evaluated two software improvements intended to address false offsets. METHODS The vendor implemented two software improvements: a volumetric (ACO) rather than planar calibration and, approximately 6 months later, an improved calibration workflow (CIB) designed to better compensate for thermal drift. Offsets relative to the reference position, obtained at table angle 0 following image-guided setup, were recorded before beam-on at each table position and at the end of treatment the table returned to 0° for patients receiving SRT. RESULTS Prior to ACO, between ACO and CIB, and after CIB, 223, 155, and 436 fractions were observed respectively. The median magnitude of translational offsets at the end of treatment was similar for all three intervals: 0.29, 0.33, and 0.27 mm. Prior to ACO, the offset magnitude for non-zero table positions had a median of 0.79 mm and was found to increase with increasing distance from isocenter to the anterior patient surface. After ACO, the median magnitude was 0.74 mm, but the dependence on surface-to-isocenter distance was eliminated. After CIB, the median magnitude for non-zero table positions was reduced to 0.57 mm. CONCLUSION Ongoing improvements in software and calibration procedures have decreased reporting of false offsets at non-zero table angles. However, the median magnitude for non-zero table angles is larger than that observed at the end of treatment, indicating that accuracy remains better when the table is not rotated.
Collapse
Affiliation(s)
- Elizabeth L Covington
- Department of Radiation Oncology, University of Alabama-Birmingham, Birmingham, AL, USA
| | - John B Fiveash
- Department of Radiation Oncology, University of Alabama-Birmingham, Birmingham, AL, USA
| | - Xingen Wu
- Department of Radiation Oncology, University of Alabama-Birmingham, Birmingham, AL, USA
| | - Ivan Brezovich
- Department of Radiation Oncology, University of Alabama-Birmingham, Birmingham, AL, USA
| | - Christopher D Willey
- Department of Radiation Oncology, University of Alabama-Birmingham, Birmingham, AL, USA
| | - Kristen Riley
- Department of Neurosurgery, University of Alabama-Birmingham, Birmingham, AL, USA
| | - Richard A Popple
- Department of Radiation Oncology, University of Alabama-Birmingham, Birmingham, AL, USA
| |
Collapse
|
18
|
Wen N, Kim J, Doemer A, Glide-Hurst C, Chetty IJ, Liu C, Laugeman E, Xhaferllari I, Kumarasiri A, Victoria J, Bellon M, Kalkanis S, Siddiqui MS, Movsas B. Evaluation of a magnetic resonance guided linear accelerator for stereotactic radiosurgery treatment. Radiother Oncol 2018; 127:460-466. [PMID: 29807837 DOI: 10.1016/j.radonc.2018.04.034] [Citation(s) in RCA: 38] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2017] [Revised: 04/30/2018] [Accepted: 04/30/2018] [Indexed: 11/30/2022]
Abstract
INTRODUCTION The purpose of this study was to investigate the systematic localization accuracy, treatment planning capability, and delivery accuracy of an integrated magnetic resonance imaging guided Linear Accelerator (MR-Linac) platform for stereotactic radiosurgery. MATERIALS AND METHODS The phantom for the end-to-end test comprises three different compartments: a rectangular MR/CT target phantom, a Winston-Lutz cube, and a rectangular MR/CT isocenter phantom. Hidden target tests were performed at gantry angles of 0, 90, 180, and 270 degrees to quantify the systematic accuracy. Five patient plans with a total of eleven lesions were used to evaluate the dosimetric accuracy. Single-isocenter IMRT treatment plans using 10-15 coplanar beams were generated to treat the multiple metastases. RESULTS The end-to-end localization accuracy of the system was 1.0 ± 0.1 mm. The conformity index, homogeneity index and gradient index of the plans were 1.26 ± 0.22, 1.22 ± 0.10, and 5.38 ± 1.44, respectively. The average absolute point dose difference between measured and calculated dose was 1.64 ± 1.90%, and the mean percentage of points passing the 3%/1 mm gamma criteria was 96.87%. CONCLUSIONS Our experience demonstrates that excellent plan quality and delivery accuracy was achievable on the MR-Linac for treating multiple brain metastases with a single isocenter.
Collapse
Affiliation(s)
- Ning Wen
- Department of Radiation Oncology, Henry Ford Health System, Detroit, USA.
| | - Joshua Kim
- Department of Radiation Oncology, Henry Ford Health System, Detroit, USA
| | - Anthony Doemer
- Department of Radiation Oncology, Henry Ford Health System, Detroit, USA
| | - Carri Glide-Hurst
- Department of Radiation Oncology, Henry Ford Health System, Detroit, USA
| | - Indrin J Chetty
- Department of Radiation Oncology, Henry Ford Health System, Detroit, USA
| | - Chang Liu
- Department of Radiation Oncology, Henry Ford Health System, Detroit, USA
| | - Eric Laugeman
- Department of Radiation Oncology, Henry Ford Health System, Detroit, USA
| | - Ilma Xhaferllari
- Department of Radiation Oncology, Henry Ford Health System, Detroit, USA
| | - Akila Kumarasiri
- Department of Radiation Oncology, Henry Ford Health System, Detroit, USA
| | | | | | - Steve Kalkanis
- Department of Neurosurgery, Henry Ford Health System, Detroit, USA
| | - M Salim Siddiqui
- Department of Radiation Oncology, Henry Ford Health System, Detroit, USA
| | - Benjamin Movsas
- Department of Radiation Oncology, Henry Ford Health System, Detroit, USA
| |
Collapse
|
19
|
Ezzell GA. The spatial accuracy of two frameless, linear accelerator-based systems for single-isocenter, multitarget cranial radiosurgery. J Appl Clin Med Phys 2017; 18:37-43. [PMID: 28300379 PMCID: PMC5689957 DOI: 10.1002/acm2.12044] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2016] [Accepted: 12/14/2016] [Indexed: 12/03/2022] Open
Abstract
Single‐isocenter, multitarget cranial stereotactic radiosurgery (SRS) is more efficient than using an isocenter for each target, but spatial positioning uncertainties can be magnified at locations away from the isocenter. This study reports on the spatial accuracy of two frameless, linac‐based SRS systems for multitarget, single‐isocenter SRS as a function of distance from the isocenter. One system uses the ExacTrac platform for image guidance and the other localizes with cone beam computed tomography (CBCT). For each platform, a phantom with 12 target BBs distributed up to 13.8 cm from the isocenter was aligned starting from five different initial offsets and then imaged with the treatment beam at seven different gantry and couch angles. The distribution of the resulting positioning errors demonstrated the value of adding a 1‐mm PTV margin for targets up to about 7–8 cm from the isocenter. For distances 10 cm or more, the CBCT‐based alignment remained within 1.1 mm while the ExacTrac‐based alignment differed by up to 2.2 mm.
Collapse
Affiliation(s)
- Gary A Ezzell
- Department of Radiation Oncology, Mayo Clinic Arizona, Phoenix, AZ, USA
| |
Collapse
|
20
|
Snyder Karen C, Liu M, Zhao B, Huang Y, Ning W, Chetty IJ, Siddiqui MS. Investigating the dosimetric effects of grid size on dose calculation accuracy using volumetric modulated arc therapy in spine stereotactic radiosurgery. JOURNAL OF RADIOSURGERY AND SBRT 2017; 4:303-313. [PMID: 29296454 PMCID: PMC5658825] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Received: 06/24/2016] [Accepted: 10/31/2016] [Indexed: 06/07/2023]
Abstract
PURPOSE Sharp dose gradients between the target and the spinal cord are critical to achieve dose constraints in spine stereotactic radiosurgery (SRS), however the accuracy of the doses to the spinal cord at these high dose gradients is sensitive to the how the dose is sampled across the structure using a discretized isotropic calculation grid. In this study, the effect of the grid size (GS) on the dosimetric accuracy of volumetric modulated arc therapy (VMAT) spine SRS plans was investigated. METHODS The Eclipse v11.0 Anisotropic Analytical Algorithm (AAA) algorithm was used for dose calculation. Plan qualities of fifty treatment plans were evaluated with a GS of 2.5 (AAA's default value), 1.5 and 1mm. All plans were prescribed to the 90% isodose line in 1 fraction. Parameters used for plan comparison included the distance-to-fall-off (DTF) between the 90% and 50% isodose levels in the axial plane, planning tumor volume (PTV) coverage to 99%, 95%, 5% and 0.03cc, dose to 10% (Cord_D10%) and 0.03cc (Cord_D0.03cc) of the spinal cord sub volume. The dosimetric accuracy was evaluated based on film dosimetry percent gamma pass rate, line profile through the cord. Calculation times between different grid sizes as well as DVH algorithm differences between two treatment planning systems (Eclipse vs Velocity) were compared. Paired t-test was used to investigate the statistical significance. RESULTS The DTF decreased for all plans with 1mm compared to 1.5mm and 2.5mm GS (2.52±0.54mm, 2.83±0.58mm, 3.30±0.64, p<0.001). Relative to the 1mm GS, Cord_D0.03cc and Cord_D10% increased by 6.24% and 7.81% with the 1.5mm GS, and 9.80% and 13% with the 2.5mm GS. Film analysis demonstrated higher gamma pass rates for 1.5mm GS compared to 1 and 2.5mm GS (95.9%±5.4%, 94.3%±6.0%, 93.6%±5.4%, p<0.001), however 1mm GS showed better agreement in the high dose gradient near the cord. Calculation times for 1mm GS plans increased for 1.5 and 2.5mm GS (61% and 84%, p<0.001). The average difference between the two treatment planning systems was approximately 0-1.2%. A maximum difference of 5.9% occurred for Cord_D0.03cc for the 1mm GS. CONCLUSION Plans calculated with a 1mm grid size resulted in the most accurate representation of the dose delivered to the cord, however resulted in less uniform dose distributions in the high dose region of the PTV. The use of a 1.5mm grid size may balance accurate cord dose and PTV coverage, while also being more practical with respect to computation time.
Collapse
Affiliation(s)
| | | | | | | | | | | | - M Salim Siddiqui
- Department of Radiation Oncology, Henry Ford Health System, 2799 W. Grand Blvd, Detroit, MI 48202, USA
| |
Collapse
|
21
|
Optimization of Treatment Geometry to Reduce Normal Brain Dose in Radiosurgery of Multiple Brain Metastases with Single-Isocenter Volumetric Modulated Arc Therapy. Sci Rep 2016; 6:34511. [PMID: 27688047 PMCID: PMC5043272 DOI: 10.1038/srep34511] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2016] [Accepted: 09/15/2016] [Indexed: 11/09/2022] Open
Abstract
Treatment of patients with multiple brain metastases using a single-isocenter volumetric modulated arc therapy (VMAT) has been shown to decrease treatment time with the tradeoff of larger low dose to the normal brain tissue. We have developed an efficient Projection Summing Optimization Algorithm to optimize the treatment geometry in order to reduce dose to normal brain tissue for radiosurgery of multiple metastases with single-isocenter VMAT. The algorithm: (a) measures coordinates of outer boundary points of each lesion to be treated using the Eclipse Scripting Application Programming Interface, (b) determines the rotations of couch, collimator, and gantry using three matrices about the cardinal axes, (c) projects the outer boundary points of the lesion on to Beam Eye View projection plane, (d) optimizes couch and collimator angles by selecting the least total unblocked area for each specific treatment arc, and (e) generates a treatment plan with the optimized angles. The results showed significant reduction in the mean dose and low dose volume to normal brain, while maintaining the similar treatment plan qualities on the thirteen patients treated previously. The algorithm has the flexibility with regard to the beam arrangements and can be integrated in the treatment planning system for clinical application directly.
Collapse
|