Zhang L, Yin FF, Li T, Teng X, Xiao H, Harris W, Ren L, Kong FMS, Ge H, Mao R, Cai J. Multi-contrast four-dimensional magnetic resonance imaging (MC-4D-MRI): Development and initial evaluation in liver tumor patients. Med Phys 2021; 48:7984-7997. [PMID: 34706072 DOI: 10.1002/mp.15314] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2020] [Revised: 07/15/2021] [Accepted: 10/06/2021] [Indexed: 12/25/2022] Open
Abstract
PURPOSE To develop a novel multi-contrast four-dimensional magnetic resonance imaging (MC-4D-MRI) technique that expands single image contrast 4D-MRI to a spectrum of native and synthetic image contrasts and to evaluate its feasibility in liver tumor patients. METHODS AND MATERIALS The MC-4D-MRI technique integrates multi-parametric MRI fusion, 4D-MRI, and deformable image registration (DIR) techniques. The fusion technique consists of native MRI as input, image pre-processing, fusion algorithm, adaptation, and fused multi-contrast MRI as output. Four-dimensional deformation vector fields (4D-DVF) were generated from an original T2/T1-w 4D-MRI by deforming end-of-inhalation (EOI) to nine other phase volumes via DIR. The 4D-DVF were applied to multi-contrast MRI to generate a spectrum of 4D-MRI in different image contrasts. The MC-4D-MRI technique was evaluated in five liver tumor patients on tumor contrast-to-noise ratio (CNR), internal target volume (ITV) contouring consistency, diaphragm motion range, and tumor motion trajectory; and in digital anthropomorphic phantoms on 4D-DIR introduced errors in tumor motion range, centroid location, extent, and volume. RESULTS MC-4D-MRI consisting of 4D-MRIs in native image contrasts (T1-w, T2-w, and T2/T1-w) and synthetic image contrasts, such as tumor-enhanced contrast (TEC) were generated in five liver tumor patients. Patient tumor CNR increased from 2.6 ± 1.8 in the T2/T1-w MRI, to -4.4 ± 2.4, 6.6 ± 3.0, and 9.6 ± 3.9 in the T1-w, T2-w, and TEC MRI, respectively. Patient ITV inter-observer mean Dice similarity coefficient (mDSC) increased from 0.65 ± 0.10 in the original T2/T1-w 4D-MRI, to 0.76 ± 0.14, 0.77 ± 0.12, and 0.86 ± 0.05 in the T1-w, T2-w, and TEC 4D-MRI, respectively. Patient diaphragm motion range absolute differences between the three new 4D-MRIs and original T2/T1-w 4D-MRI were 1.2 ± 1.3, 0.3 ± 0.7, and 0.5 ± 0.5 mm, respectively. Patient tumor displacement phase-averaged absolute differences between the three 4D-MRIs and the original 4D-MRI were 0.72 ± 0.33, 0.62 ± 0.54, and 0.74 ± 0.43 mm in the superior-inferior (SI) direction, and 0.59 ± 0.36, 0.51 ± 0.30, and 0.50 ± 0.24 mm in the anterior-posterior (AP) direction, respectively. In the digital phantoms, phase-averaged absolute tumor centroid shift caused by the 4D-DIR were at or below 0.5 mm in SI, AP, and left-right (LR) directions. CONCLUSION We developed an MC-4D-MRI technique capable of expanding single image contrast 4D-MRI along a new dimension of image contrast. Initial evaluations in liver tumor patients showed enhancements in image contrast variety, tumor contrast, and ITV contouring consistencies using MC-4D-MRI. The technique might offer new perspectives on the image contrast of MRI and 4D-MRI in MR-guided radiotherapy.
Collapse
Affiliation(s)
- Lei Zhang
- Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina, USA.,Medical Physics Graduate Program, Duke University, Durham, North Carolina, USA
| | - Fang-Fang Yin
- Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina, USA.,Medical Physics Graduate Program, Duke University, Durham, North Carolina, USA
| | - Tian Li
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, China
| | - Xinzhi Teng
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, China
| | - Haonan Xiao
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, China
| | - Wendy Harris
- Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina, USA.,Medical Physics Graduate Program, Duke University, Durham, North Carolina, USA
| | - Lei Ren
- Department of Radiation Oncology, University of Maryland, Baltimore, Maryland, USA
| | | | - Hong Ge
- Department of Radiation Oncology, The Affiliated Cancer Hospital of Zhengzhou University, Zhengzhou, Henan, China
| | - Ronghu Mao
- Department of Radiation Oncology, The Affiliated Cancer Hospital of Zhengzhou University, Zhengzhou, Henan, China
| | - Jing Cai
- Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina, USA.,Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, China
| |
Collapse
|
2
|
Mickevicius NJ, Paulson ES. On the use of low-dimensional temporal subspace constraints to reduce reconstruction time and improve image quality of accelerated 4D-MRI. Radiother Oncol 2021; 158:215-223. [PMID: 33412207 DOI: 10.1016/j.radonc.2020.12.032] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2020] [Revised: 12/18/2020] [Accepted: 12/20/2020] [Indexed: 11/29/2022]
Abstract
BACKGROUND AND PURPOSE The purpose of this work is to investigate the use of low-dimensional temporal subspace constraints for 4D-MRI reconstruction from accelerated data in the context of MR-guided online adaptive radiation therapy (MRgOART). MATERIALS AND METHODS Subspace basis functions are derived directly from the accelerated golden angle radial stack-of-stars 4D-MRI data. The reconstruction times, image quality, and motion estimates are investigated as a function of the number of subspace coefficients and compared with a conventional frame-by-frame reconstruction. These experiments were performed in five patients with four 4D-MRI scans per patient on a 1.5T MR-Linac. RESULTS If two or three subspace coefficients are used, the iterative reconstruction time is reduced by 32% and 18%, respectively, compared to conventional parallel imaging with compressed sensing reconstructions. No significant difference was found between motion estimates made with the subspace-constrained reconstructions (p > 0.08). Qualitative improvements in image quality included reduction in apparent noise and reductions in streaking artifacts from the radial k-space coverage. CONCLUSION Incorporating subspace constraints for accelerated 4D-MRI reconstruction reduces noise and residual undersampling artifacts in the images while reducing computation time, making it a strong candidate for use in clinical MRgOART workflows.
Collapse
Affiliation(s)
| | - Eric S Paulson
- Department of Radiation Oncology, Medical College of Wisconsin, United States; Department of Radiology, Medical College of Wisconsin, United States; Department of Biophysics, Medical College of Wisconsin, United States
| |
Collapse
|
4
|
Sun D, Liang X, Yin F, Cai J. Probability-based 3D k-space sorting for motion robust 4D-MRI. Quant Imaging Med Surg 2019; 9:1326-1336. [PMID: 31448217 DOI: 10.21037/qims.2019.07.06] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
BACKGROUND Current 4D-MRI techniques are prone to breathing-variation-induced motion artifacts. This study developed a novel method for motion-robust multi-cycle 4D-MRI using probability-based multi-cycle sorting to overcome this deficiency. METHODS The main cycles were first extracted from the breathing signal. 3D k-space data were then sorted using a result-driven method for each main cycle. The new method was tested on a 4D-extended cardiac-torso (XCAT) phantom with a patient and an artificially generated breathing curve. For comparison, the k-space data were sorted using conventional phase sorting to generate single-cycle 4D-MRI images. Signal-to-noise ratio (SNR) of tumor and liver, tumor volume consistency, and average intensity projection (AIP) accuracy were compared between the two methods. The original phantom images were used as references for the evaluation. RESULTS The new method showed improved tumor-to-liver SNR and tumor volume consistency as compared to 3D k-space phase sorting in both the simulated artificial and real patient breathing signals. For the artificial breathing cycles, the average tumor-to-liver SNR and standard deviation (SD) of tumor volume were 2.53 and 3.80% for cycle 1, 2.24 and 6.16% for cycle 2 of probability-based sorting as compared to 1.47 and 21.83% obtained using the phase sorting method; for the patient breathing curve, values of 1.99 and 2.71%, 1.97 and 3.29%, 1.88 and 4.16% were observed for cycle 1, cycle 2 and cycle 3 of probability-based sorting, versus 1.44 and 7.20% for phase sorting method. Furthermore, the AIP accuracy was improved in the probability-based sorting approach when compared to phase sorting, with the average intensity difference per voxel reduced from 0.39 to 0.15 for the artificial curve, and from 0.46 to 0.21 for the patient curve. CONCLUSIONS We demonstrated the feasibility of probability-based 3D k-space sorting for motion-robust multi-cycle 4D-MRI reconstruction with breathing variation induced motion artifact reduction compared with conventional 2D image sorting and 3D phase sorting methods. This new technique can potentially improve the accuracy of radiation treatment guidance for mobile targets.
Collapse
Affiliation(s)
- Duohua Sun
- Medical Physics Graduate Program, Duke Kunshan University, Kunshan 215316, China
| | - Xiao Liang
- Medical Physics Graduate Program, Duke University, Durham, NC, USA
| | - Fangfang Yin
- Medical Physics Graduate Program, Duke Kunshan University, Kunshan 215316, China.,Medical Physics Graduate Program, Duke University, Durham, NC, USA.,Department of Radiation Oncology, Duke University Medical Center, Durham, NC, USA
| | - Jing Cai
- Medical Physics Graduate Program, Duke University, Durham, NC, USA.,Department of Radiation Oncology, Duke University Medical Center, Durham, NC, USA.,Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, China
| |
Collapse
|
5
|
Paganelli C, Whelan B, Peroni M, Summers P, Fast M, van de Lindt T, McClelland J, Eiben B, Keall P, Lomax T, Riboldi M, Baroni G. MRI-guidance for motion management in external beam radiotherapy: current status and future challenges. Phys Med Biol 2018; 63:22TR03. [PMID: 30457121 DOI: 10.1088/1361-6560/aaebcf] [Citation(s) in RCA: 82] [Impact Index Per Article: 13.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
High precision conformal radiotherapy requires sophisticated imaging techniques to aid in target localisation for planning and treatment, particularly when organ motion due to respiration is involved. X-ray based imaging is a well-established standard for radiotherapy treatments. Over the last few years, the ability of magnetic resonance imaging (MRI) to provide radiation-free images with high-resolution and superb soft tissue contrast has highlighted the potential of this imaging modality for radiotherapy treatment planning and motion management. In addition, these advantageous properties motivated several recent developments towards combined MRI radiation therapy treatment units, enabling in-room MRI-guidance and treatment adaptation. The aim of this review is to provide an overview of the state-of-the-art in MRI-based image guidance for organ motion management in external beam radiotherapy. Methodological aspects of MRI for organ motion management are reviewed and their application in treatment planning, in-room guidance and adaptive radiotherapy described. Finally, a roadmap for an optimal use of MRI-guidance is highlighted and future challenges are discussed.
Collapse
Affiliation(s)
- C Paganelli
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milano, Italy. Author to whom any correspondence should be addressed. www.cartcas.polimi.it
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|