Baroudi H, Chen X, Cao W, El Basha MD, Gay S, Gronberg MP, Hernandez S, Huang K, Kaffey Z, Melancon AD, Mumme RP, Sjogreen C, Tsai JY, Yu C, Court LE, Pino R, Zhao Y. Synthetic Megavoltage Cone Beam Computed Tomography Image Generation for Improved Contouring Accuracy of Cardiac Pacemakers. J Imaging 2023; 9:245. [PMID: 37998092 PMCID: PMC10672228 DOI: 10.3390/jimaging9110245] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2023] [Revised: 10/31/2023] [Accepted: 11/02/2023] [Indexed: 11/25/2023] Open
Abstract
In this study, we aimed to enhance the contouring accuracy of cardiac pacemakers by improving their visualization using deep learning models to predict MV CBCT images based on kV CT or CBCT images. Ten pacemakers and four thorax phantoms were included, creating a total of 35 combinations. Each combination was imaged on a Varian Halcyon (kV/MV CBCT images) and Siemens SOMATOM CT scanner (kV CT images). Two generative adversarial network (GAN)-based models, cycleGAN and conditional GAN (cGAN), were trained to generate synthetic MV (sMV) CBCT images from kV CT/CBCT images using twenty-eight datasets (80%). The pacemakers in the sMV CBCT images and original MV CBCT images were manually delineated and reviewed by three users. The Dice similarity coefficient (DSC), 95% Hausdorff distance (HD95), and mean surface distance (MSD) were used to compare contour accuracy. Visual inspection showed the improved visualization of pacemakers on sMV CBCT images compared to original kV CT/CBCT images. Moreover, cGAN demonstrated superior performance in enhancing pacemaker visualization compared to cycleGAN. The mean DSC, HD95, and MSD for contours on sMV CBCT images generated from kV CT/CBCT images were 0.91 ± 0.02/0.92 ± 0.01, 1.38 ± 0.31 mm/1.18 ± 0.20 mm, and 0.42 ± 0.07 mm/0.36 ± 0.06 mm using the cGAN model. Deep learning-based methods, specifically cycleGAN and cGAN, can effectively enhance the visualization of pacemakers in thorax kV CT/CBCT images, therefore improving the contouring precision of these devices.
Collapse
Affiliation(s)
- Hana Baroudi
- MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences, The University of Texas, Houston, TX 77030, USA
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
| | - Xinru Chen
- MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences, The University of Texas, Houston, TX 77030, USA
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
| | - Wenhua Cao
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
| | - Mohammad D. El Basha
- MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences, The University of Texas, Houston, TX 77030, USA
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
| | - Skylar Gay
- MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences, The University of Texas, Houston, TX 77030, USA
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
| | - Mary Peters Gronberg
- MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences, The University of Texas, Houston, TX 77030, USA
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
| | - Soleil Hernandez
- MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences, The University of Texas, Houston, TX 77030, USA
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
| | - Kai Huang
- MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences, The University of Texas, Houston, TX 77030, USA
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
| | - Zaphanlene Kaffey
- MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences, The University of Texas, Houston, TX 77030, USA
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
| | - Adam D. Melancon
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
| | - Raymond P. Mumme
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
| | - Carlos Sjogreen
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
| | - January Y. Tsai
- Department of Anesthesiology and Perioperative Medicine, Division of Anesthesiology, Critical Care Medicine and Pain Medicine, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
| | - Cenji Yu
- MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences, The University of Texas, Houston, TX 77030, USA
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
| | - Laurence E. Court
- MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences, The University of Texas, Houston, TX 77030, USA
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
| | - Ramiro Pino
- Department of Radiation Oncology, Houston Methodist Hospital, Houston, TX 77030, USA
| | - Yao Zhao
- MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences, The University of Texas, Houston, TX 77030, USA
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
| |
Collapse
|
2
|
Azraai M, D'Souza D, Nadurata V. Current Clinical Practice in Patients With Cardiac Implantable Electronic Devices (CIED) Undergoing Radiotherapy (RT). Heart Lung Circ 2021; 31:327-340. [PMID: 34844904 DOI: 10.1016/j.hlc.2021.10.020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2021] [Revised: 10/05/2021] [Accepted: 10/25/2021] [Indexed: 11/26/2022]
Abstract
Patients with cardiac implantable electronic devices (CIED) undergoing radiotherapy (RT) are more common due to ageing of the population. With newer CIEDs implementing the complementary metal-oxide semiconductor (CMOS) technology which allows the miniaturisation of CIED, it is also more susceptible to RT. Effects of RT on CIED ranges from device interference, device operational/memory errors of permanent damage. These malfunctions can cause life threatening clinical effects. Cumulative dose is not the only component of RT that causes CIED malfunction, as neutron use and dose rate effect also affects CIEDs. The management of this patient cohort in clinical practice is inconsistent due to lack of a consistent guideline from manufacturers and physician specialty societies. Our review will focus on the current clinical practice and the recent updated guidelines of managing patients with CIED undergoing RT. We aim to simplify the evidence and provide a simple and easy to use guide based on the recent guidelines.
Collapse
Affiliation(s)
- Meor Azraai
- Department of Cardiology, Bendigo Health, Bendigo, Vic, Australia.
| | - Daniel D'Souza
- Department of Cardiology, Bendigo Health, Bendigo, Vic, Australia
| | | |
Collapse
|
3
|
Miften M, Mihailidis D, Kry SF, Reft C, Esquivel C, Farr J, Followill D, Hurkmans C, Liu A, Gayou O, Gossman M, Mahesh M, Popple R, Prisciandaro J, Wilkinson J. Management of radiotherapy patients with implanted cardiac pacemakers and defibrillators: A Report of the AAPM TG-203 †. Med Phys 2019; 46:e757-e788. [PMID: 31571229 DOI: 10.1002/mp.13838] [Citation(s) in RCA: 70] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2019] [Revised: 07/16/2019] [Accepted: 08/28/2019] [Indexed: 11/11/2022] Open
Abstract
Managing radiotherapy patients with implanted cardiac devices (implantable cardiac pacemakers and implantable cardioverter-defibrillators) has been a great practical and procedural challenge in radiation oncology practice. Since the publication of the AAPM TG-34 in 1994, large bodies of literature and case reports have been published about different kinds of radiation effects on modern technology implantable cardiac devices and patient management before, during, and after radiotherapy. This task group report provides the framework that analyzes the potential failure modes of these devices and lays out the methodology for patient management in a comprehensive and concise way, in every step of the entire radiotherapy process.
Collapse
Affiliation(s)
- Moyed Miften
- Task Group 203, Department of Radiation Oncology, University of Colorado School of Medicine, Aurora, CO, 80045, USA
| | - Dimitris Mihailidis
- Task Group 203, University of Pennsylvania, Perelman Center for Advanced Medicine, Philadelphia, PA, 19104, USA
| | - Stephen F Kry
- Department of Radiation Physics, UT MD Anderson Cancer Center, Houston, TX, 77030, USA
| | - Chester Reft
- Department of Radiation Oncology, University of Chicago, Chicago, IL, 60637, USA
| | - Carlos Esquivel
- Department of Radiation Oncology, UT Health Sciences Center, San Antonio, TX, 78229, USA
| | - Jonathan Farr
- Division of Radiological Sciences, St. Jude Children's Research Hospital, Memphis, TN, 38105, USA
| | - David Followill
- Department of Radiation Physics, UT MD Anderson Cancer Center, Houston, TX, 77030, USA
| | - Coen Hurkmans
- Department of Radiotherapy, Catharina Hospital, Eindhoven, the Netherlands
| | - Arthur Liu
- Department of Radiation Oncology, University of Colorado School of Medicine, Aurora, CO, 80045, USA
| | - Olivier Gayou
- Department of Radiation Oncology, Allegheny General Hospital, Pittsburg, PA, 15212, USA
| | - Michael Gossman
- Department of Radiation Oncology, Tri-State Regional Cancer Center, Ashland, KY, 41101, USA
| | - Mahadevappa Mahesh
- Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, MD, 21287, USA
| | - Richard Popple
- Department of Radiation Oncology, University of Alabama, Birmingham, AL, 35249, USA
| | - Joann Prisciandaro
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI, 48109, USA
| | | |
Collapse
|
4
|
Haranhalli N, Zeberg H, Lasala P, Altschul D. Radiolucent Skull Clamps for Intra-Operative Imaging: A Technical Note. Cureus 2017; 9:e1020. [PMID: 28348939 PMCID: PMC5346026 DOI: 10.7759/cureus.1020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2016] [Accepted: 02/10/2017] [Indexed: 12/04/2022] Open
Abstract
Conventionally, surgery and procedural-based radiology are performed on different premises. With advances in imaging technology, the operating room is rapidly being transformed into an intraoperative imaging suite. Diagnostic imaging in conjunction with surgery has great utility and by all accounts has great future potential. During the last decade, cone beam computed tomography (CT) scanners have been introduced and have made intraoperative imaging more feasible because these scanners can be made less bulky. The current usefulness of intraoperative magnetic resonance imaging (MRI) or CT for neurosurgery, however, is impaired by the lack of completely radiolucent skull clamps, causing image artifacts. Metal artifacts are particularly problematic, given that they lead to a considerably higher image quality degradation factor for cone beam CT scanners than for conventional CT scanners. Here, we describe our experience with near-radiolucent skull clamps and their associated problems and discuss future improvements to facilitate high-quality image guidance in the field of neurosurgery.
Collapse
Affiliation(s)
- Neil Haranhalli
- Department of Neurological Surgery, Montefiore Medical Center
| | | | - Patrick Lasala
- Department of Neurological Surgery, Montefiore Medical Center
| | - David Altschul
- Department of Neurological Surgery, Montefiore Medical Center
| |
Collapse
|
5
|
Measuring dose from radiotherapy treatments in the vicinity of a cardiac pacemaker. Phys Med 2016; 32:1529-1536. [PMID: 27881295 DOI: 10.1016/j.ejmp.2016.11.010] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/16/2016] [Revised: 11/03/2016] [Accepted: 11/07/2016] [Indexed: 11/23/2022] Open
Abstract
This study investigated the dose absorbed by tissues surrounding artificial cardiac pacemakers during external beam radiotherapy procedures. The usefulness of out-of-field reference data, treatment planning systems, and skin dose measurements to estimate the dose in the vicinity of a pacemaker was also examined. Measurements were performed by installing a pacemaker onto an anthropomorphic phantom, and using radiochromic film and optically stimulated luminescence dosimeters to measure the dose in the vicinity of the device during the delivery of square fields and clinical treatment plans. It was found that the dose delivered in the vicinity of the cardiac device was unevenly distributed both laterally and anteroposteriorly. As the device was moved distally from the square field, the dose dropped exponentially, in line with out-of-field reference data in the literature. Treatment planning systems were found to substantially underestimate the dose for volumetric modulated arc therapy, helical tomotherapy, and 3D conformal treatments. The skin dose was observed to be either greater or lesser than the dose received at the depth of the device, depending on the treatment site, and so care should be if skin dose measurements are to be used to estimate the dose to a pacemaker. Square field reference data may be used as an upper estimate of absorbed dose per monitor unit in the vicinity of a cardiac device for complex treatments involving multiple gantry angles.
Collapse
|
6
|
Prisciandaro JI, Makkar A, Fox CJ, Hayman JA, Horwood L, Pelosi F, Moran JM. Dosimetric review of cardiac implantable electronic device patients receiving radiotherapy. J Appl Clin Med Phys 2015; 16:5189. [PMID: 25679176 PMCID: PMC5689988 DOI: 10.1120/jacmp.v16i1.5189] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2014] [Revised: 10/15/2014] [Accepted: 10/10/2014] [Indexed: 11/23/2022] Open
Abstract
A formal communication process was established and evaluated for the management of patients with cardiac implantable electronic devices (CIEDs) receiving radiation therapy (RT). Methods to estimate dose to the CIED were evaluated for their appropriateness in the management of these patients. A retrospective, institutional review board (IRB) approved study of 69 patients with CIEDs treated with RT between 2005 and 2011 was performed. The treatment sites, techniques, and the estimated doses to the CIEDs were analyzed and compared to estimates from published peripheral dose (PD) data and three treatment planning systems (TPSs) — UMPlan, Eclipse's AAA and Acuros algorithms. When measurements were indicated, radiation doses to the CIEDs ranged from 0.01–5.06 Gy. Total peripheral dose estimates based on publications differed from TLD measurements by an average of 0.94 Gy (0.05–4.49 Gy) and 0.51 Gy (0–2.74 Gy) for CIEDs within 2.5 cm and between 2.5 and 10 cm of the treatment field edge, respectively. Total peripheral dose estimates based on three TPSs differed from measurements by an average of 0.69 Gy (0.02–3.72 Gy) for CIEDs within 2.5 cm of the field edge. Of the 69 patients evaluated in this study, only two with defibrillators experienced a partial reset of their device during treatment. Based on this study, few CIED‐related events were observed during RT. The only noted correlation with treatment parameters for these two events was beam energy, as both patients were treated with high‐energy photon beams (16 MV). Differences in estimated and measured CIED doses were observed when using published PD data and TPS calculations. As such, we continue to follow conservative guidelines and measure CIED doses when the device is within 10 cm of the field or the estimated dose is greater than 2 Gy for pacemakers or 1 Gy for defibrillators. PACS number: 87.55.N‐
Collapse
|
7
|
Borkenhagen JF, Morris ZS, Hoberg JR, Kozak KR, Shapiro LQ. Delivery of definitive dose external beam radiation in close proximity to an implanted deep brain stimulator. Pract Radiat Oncol 2014; 4:294-297. [PMID: 25194097 DOI: 10.1016/j.prro.2013.10.003] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2013] [Revised: 10/02/2013] [Accepted: 10/03/2013] [Indexed: 11/26/2022]
Affiliation(s)
- Jenna F Borkenhagen
- University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin
| | - Zachary S Morris
- Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin
| | - Jacob R Hoberg
- Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin
| | - Kevin R Kozak
- Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin
| | - Lauren Q Shapiro
- Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin.
| |
Collapse
|
8
|
Treatment approach, delivery, and follow-up evaluation for cardiac rhythm disease management patients receiving radiation therapy: Retrospective physician surveys including chart reviews at numerous centers. Med Dosim 2014; 39:320-4. [DOI: 10.1016/j.meddos.2014.05.005] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2013] [Revised: 05/06/2014] [Accepted: 05/06/2014] [Indexed: 11/23/2022]
|
9
|
Gossman MS, Blohm CM. Beam profile disturbances from interactions with implantable pacemakers and implantable cardioverter-defibrillators. Med Dosim 2013; 38:109. [PMID: 23290193 DOI: 10.1016/j.meddos.2012.10.008] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2012] [Accepted: 10/30/2012] [Indexed: 11/16/2022]
|
10
|
Sung W, Kim S, Kim JI, Lee JG, Shin YJ, Jung JY, Ye SJ. Dosimetric perturbations due to an implanted cardiac pacemaker in MammoSite® treatment. Med Phys 2012; 39:6185-91. [DOI: 10.1118/1.4752088] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023] Open
|
11
|
Evaluation of a ventricular assist device: stability under x-rays and therapeutic beam attenuation. ASAIO J 2012; 58:212-6. [PMID: 22236626 DOI: 10.1097/mat.0b013e3182468318] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
Improved outcomes and quality of life of heart failure patients have been reported with the use of left ventricular assist devices (LVADs). However, little information exists regarding devices in patients undergoing radiation cancer treatment. Two HeartWare Ventricular Assist Device (HVAD) pumps were repeatedly irradiated with high intensity 18 MV x-rays to a dosage range of 64-75 Gy at a rate of 6 Gy/min from a radiation oncology particle accelerator to determine operational stability. Pump parameter data was collected through a data acquisition system. Second, a computerized tomography (CT) scan was taken of the device, and a treatment planning computer estimated characteristics of dose scattering and attenuation. Results were then compared with actual radiation measurements. The devices exhibited no changes in pump operation during the procedure, though the titanium components of the HVAD markedly attenuate the therapy beam. Computer modeling indicated an 11.8% dose change in the absorbed dosage that was distinctly less than the 84% dose change measured with detectors. Simulated and measured scattering processes were negligible. Computer modeling underestimates pretreatment dose to patients when the device is in the field of radiation. Future x-ray radiation dosimetry and treatment planning in HVAD patients should be carefully managed by radiation oncology specialists.
Collapse
|
12
|
Fattahi S, Ostapiak OZ. An opposed matched field IMRT technique for prostate cancer patients with bilateral prosthetic hips. J Appl Clin Med Phys 2012; 13:3347. [PMID: 22231205 PMCID: PMC5716138 DOI: 10.1120/jacmp.v13i1.3347] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2010] [Accepted: 08/19/2011] [Indexed: 11/23/2022] Open
Abstract
Intensity‐modulated radiation therapy (IMRT) has gained wide‐spread use for treating patients with prostate cancer, yet developing a plan for patients with bi‐lateral metal hip prostheses implants may be challenging. The high atomic number of the metallic hips not only gives rise to streak artifacts that obscure anatomy but also attenuates laterally directed fields by a significant amount that cannot be reliably ascertained from the CT dataset. A common approach to planning directs five IMRT fields such that incidence through the metal hips is avoided. While this technique generally gives adequate PTV coverage, it may escalate the rectal dose if beams, which would otherwise be incident from a lateral direction, are angled toward a posterior direction in order to avoid the prosthesis. In this work, we propose and investigate a new technique which alleviates this problem by introducing asymmetric opposed fields that are edge‐matched along a plane that is tangent to the metal prostheses. With this approach, a posterior oblique field is oriented closer to the lateral direction but does not irradiate the ipsilateral prosthesis. The portion of the target eclipsed by the prosthesis is irradiated by the opposed matched anterior oblique field which, again, avoids the corresponding ipsilateral prosthesis. While the proposed technique may improve rectal sparing and PTV coverage, the dose along the match plane is sensitive to intrafraction motion. In the worse case of intrafraction motion perpendicular to the plane occurring in the time interval between the deliveries of successive fields of the opposed matched pair, the induced error is typically about 5 cGy per mm of target motion for a 200 cGy fraction. To reduce the induced error, several approaches to broadening the penumbra at the match plane were investigated and compared to conventional IMRT plans for three patients. Phantom measurements were performed to evaluate the effectiveness of these approaches. Match‐plane shifts of 4 mm in a single step, in two 2 mm steps, and in four 1 mm steps, were effective in reducing the worse case induced error to 2.8 cGy per mm. Imposing match‐plane shifts precludes the use of intensity modulation for the opposed matched field pairs. Therefore, we favor an approach whereby the opposed matched fields overlap by 4 mm. Since both fields contribute fluence to the overlap region, the worse case induced error was observed to be typically within 2.9 cGy per mm. In conclusion, the use of this technique should be considered for patients with bilateral metal hip implants who do not meet dose‐volume criteria by conventional IMRT techniques. PACS number: 87.55.‐x
Collapse
Affiliation(s)
- Shahin Fattahi
- Department of Medical Physics, Juravinski Cancer Centre, Hamilton, ON, Canada L8V 5C2
| | | |
Collapse
|
13
|
Beam Profile Disturbances from Implantable Pacemakers or Implantable Cardioverter-Defibrillator Interactions. Med Dosim 2011; 36:358-64. [DOI: 10.1016/j.meddos.2010.09.003] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2010] [Revised: 08/31/2010] [Accepted: 09/08/2010] [Indexed: 11/18/2022]
|