1
|
Kästner D, Braune A, Brogsitter C, Freudenberg R, Kotzerke J, Michler E. Gamma camera imaging characteristics of 166Ho and 99mTc used in Selective Internal Radiation Therapy. EJNMMI Phys 2024; 11:35. [PMID: 38581559 PMCID: PMC10998827 DOI: 10.1186/s40658-024-00633-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2023] [Accepted: 03/20/2024] [Indexed: 04/08/2024] Open
Abstract
BACKGROUND The administration of a 166Ho scout dose is available as an alternative to 99mTc particles for pre-treatment imaging in Selective Internal Radiation Therapy (SIRT). It has been reported that the 166Ho scout dose may be more accurate for the prediction of microsphere distribution and the associated therapy planning. The aim of the current study is to compare the scintigraphic imaging characteristics of both isotopes, considering the objectives of the pre-treatment imaging using clinically geared phantoms. METHODS Planar and SPECT/CT images were obtained using a NEMA image quality phantom in different phantom setups and another body-shaped phantom with several inserts. The influence of collimator type, count statistics, dead time effects, isotope properties and patient obesity on spatial resolution, contrast recovery and the detectability of small activity accumulations was investigated. Furthermore, the effects of the imaging characteristics on personalized dosimetry are discussed. RESULTS The images with 99mTc showed up to 3 mm better spatial resolution, up to two times higher contrast recovery and significantly lower image noise than those with 166Ho. The contrast-to-noise ratio was up to five times higher for 99mTc than for 166Ho. Only when using 99mTc all activity-filled spheres could be distinguished from the activity-filled background. The measurements mimicking an obese patient resulted in a degraded image quality for both isotopes. CONCLUSIONS Our measurements demonstrate better scintigraphic imaging properties for 99mTc compared to 166Ho in terms of spatial resolution, contrast recovery, image noise, and lesion detectability. While the 166Ho scout dose promises better prediction of the microsphere distribution, it is important to consider the inferior imaging characteristics of 166Ho, which may affect individualized treatment planning in SIRT.
Collapse
Affiliation(s)
- David Kästner
- Department of Nuclear Medicine, University Hospital Carl Gustav Carus, Technische Universität Dresden, Fetscherstraße 74, 01307, Dresden, Germany.
| | - Anja Braune
- Department of Nuclear Medicine, University Hospital Carl Gustav Carus, Technische Universität Dresden, Fetscherstraße 74, 01307, Dresden, Germany
| | - Claudia Brogsitter
- Department of Nuclear Medicine, University Hospital Carl Gustav Carus, Technische Universität Dresden, Fetscherstraße 74, 01307, Dresden, Germany
| | - Robert Freudenberg
- Department of Nuclear Medicine, University Hospital Carl Gustav Carus, Technische Universität Dresden, Fetscherstraße 74, 01307, Dresden, Germany
| | - Jörg Kotzerke
- Department of Nuclear Medicine, University Hospital Carl Gustav Carus, Technische Universität Dresden, Fetscherstraße 74, 01307, Dresden, Germany
- Faculty of Medicine Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - Enrico Michler
- Department of Nuclear Medicine, University Hospital Carl Gustav Carus, Technische Universität Dresden, Fetscherstraße 74, 01307, Dresden, Germany
| |
Collapse
|
2
|
Frangos S, Michael K, Exadaktylou P, Giannoula E, Iakovou I. The Anger's camera. Nucl Med Mol Imaging 2022. [DOI: 10.1016/b978-0-12-822960-6.00159-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
|
3
|
Abstract
Cerebrovascular disease is a significant cause of cognitive impairment leading to a reduction or loss of functioning, including social and occupational. The connection cause-effect between cerebrovascular disease and cerebral infarction was originally theorized by the studies from Newcastle-Upon-Tyne, England, in the 1960s, where vascular dementia (VaD) was defined as a disease originated from several infarctions that overcome a determined threshold. It differs from Alzheimer's disease (AD), although there are various overlaps in risk factors, symptomatology, the similarity of vascular lesions, and treatment benefits. Nevertheless, AD is one-half of all cases of dementia. Cognitive impairment and dementia (VCID) has recently been proposed to include different entities such as VaD, Vascular cognitive impairment, subcortical (ischemic) VaD, and vascular cognitive disorders. VaD is the most common cause of dementia after AD. Neuroimaging is an essential part of the workup of patients with cognitive decline and in those with suspected VCID it should be used to assess the extent, location, and type of vascular lesions. Computed tomography (CT) or structural magnetic resonance imaging (MRI) are usually used for the diagnosis of vascular diseases of the brain. However, images obtained from new hybrid devices could help the neurologist in the differential diagnosis between various neuropathological entities related to VCID. Single-photon emission computed tomography (SPECT) combined with CT or MRI and positron emission tomography (PET) combined with CT or MRI represent the future of neuroimaging tools as morphological and functional data can be provided simultaneously. New prospects have been developed such as hybrid PET/SPECT/CT, a high-performance prototype able to produce high-quality images but for now suitable only for small animals. Nowadays, PET/CT and PET/MRI are good performance and high-quality instruments, even if the magnetic field of MRI represents a limitation that affects the PET electronics and positron detection ability. SPECT/MRI delineates as a potential and tempting device. It could give us both functional and anatomical details, with the advantage of lack of extra ionizing radiation and high soft-tissue contrast, important features, and considerable auxiliary for differential diagnosis in the variegate word of vascular cognitive impairment. The aim of this review is to summarize the newest viewpoints in hybrid imaging in the diagnosis of VaD and to highlight pros and cons of each methodic.
Collapse
Affiliation(s)
| | - Miriam Conte
- Department of Radiological Sciences, Oncology and Anatomical Pathology, Sapienza University of Rome, Rome, Italy
| | - Giuseppe De Vincentis
- Department of Radiological Sciences, Oncology and Anatomical Pathology, Sapienza University of Rome, Rome, Italy
| |
Collapse
|
4
|
Stam MK, Verwer EE, Booij J, Adriaanse SM, de Bruin CM, de Wit TC. Performance evaluation of a novel brain-dedicated SPECT system. EJNMMI Phys 2018; 5:4. [PMID: 29492787 PMCID: PMC5833889 DOI: 10.1186/s40658-018-0203-1] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2017] [Accepted: 01/05/2018] [Indexed: 11/10/2022] Open
Affiliation(s)
- M K Stam
- Department of Radiology and Nuclear Medicine, Academic Medical Center, PO box 22660, 1100, DD, Amsterdam, The Netherlands
| | - E E Verwer
- Department of Radiology and Nuclear Medicine, Academic Medical Center, PO box 22660, 1100, DD, Amsterdam, The Netherlands
| | - J Booij
- Department of Radiology and Nuclear Medicine, Academic Medical Center, PO box 22660, 1100, DD, Amsterdam, The Netherlands
| | - S M Adriaanse
- Department of Radiology and Nuclear Medicine, Academic Medical Center, PO box 22660, 1100, DD, Amsterdam, The Netherlands
| | - C M de Bruin
- Department of Radiology and Nuclear Medicine, Academic Medical Center, PO box 22660, 1100, DD, Amsterdam, The Netherlands
| | - T C de Wit
- Department of Radiology and Nuclear Medicine, Academic Medical Center, PO box 22660, 1100, DD, Amsterdam, The Netherlands.
| |
Collapse
|
5
|
Li S, Zhang J, Krol A, Schmidtlein CR, Vogelsang L, Shen L, Lipson E, Feiglin D, Xu Y. Effective noise-suppressed and artifact-reduced reconstruction of SPECT data using a preconditioned alternating projection algorithm. Med Phys 2016; 42:4872-87. [PMID: 26233214 DOI: 10.1118/1.4926846] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE The authors have recently developed a preconditioned alternating projection algorithm (PAPA) with total variation (TV) regularizer for solving the penalized-likelihood optimization model for single-photon emission computed tomography (SPECT) reconstruction. This algorithm belongs to a novel class of fixed-point proximity methods. The goal of this work is to investigate how PAPA performs while dealing with realistic noisy SPECT data, to compare its performance with more conventional methods, and to address issues with TV artifacts by proposing a novel form of the algorithm invoking high-order TV regularization, denoted as HOTV-PAPA, which has been explored and studied extensively in the present work. METHODS Using Monte Carlo methods, the authors simulate noisy SPECT data from two water cylinders; one contains lumpy "warm" background and "hot" lesions of various sizes with Gaussian activity distribution, and the other is a reference cylinder without hot lesions. The authors study the performance of HOTV-PAPA and compare it with PAPA using first-order TV regularization (TV-PAPA), the Panin-Zeng-Gullberg one-step-late method with TV regularization (TV-OSL), and an expectation-maximization algorithm with Gaussian postfilter (GPF-EM). The authors select penalty-weights (hyperparameters) by qualitatively balancing the trade-off between resolution and image noise separately for TV-PAPA and TV-OSL. However, the authors arrived at the same penalty-weight value for both of them. The authors set the first penalty-weight in HOTV-PAPA equal to the optimal penalty-weight found for TV-PAPA. The second penalty-weight needed for HOTV-PAPA is tuned by balancing resolution and the severity of staircase artifacts. The authors adjust the Gaussian postfilter to approximately match the local point spread function of GPF-EM and HOTV-PAPA. The authors examine hot lesion detectability, study local spatial resolution, analyze background noise properties, estimate mean square errors (MSEs), and report the convergence speed and computation time. RESULTS HOTV-PAPA yields the best signal-to-noise ratio, followed by TV-PAPA and TV-OSL/GPF-EM. The local spatial resolution of HOTV-PAPA is somewhat worse than that of TV-PAPA and TV-OSL. Images reconstructed using HOTV-PAPA have the lowest local noise power spectrum (LNPS) amplitudes, followed by TV-PAPA, TV-OSL, and GPF-EM. The LNPS peak of GPF-EM is shifted toward higher spatial frequencies than those for the three other methods. The PAPA-type methods exhibit much lower ensemble noise, ensemble voxel variance, and image roughness. HOTV-PAPA performs best in these categories. Whereas images reconstructed using both TV-PAPA and TV-OSL are degraded by severe staircase artifacts; HOTV-PAPA substantially reduces such artifacts. It also converges faster than the other three methods and exhibits the lowest overall reconstruction error level, as measured by MSE. CONCLUSIONS For high-noise simulated SPECT data, HOTV-PAPA outperforms TV-PAPA, GPF-EM, and TV-OSL in terms of hot lesion detectability, noise suppression, MSE, and computational efficiency. Unlike TV-PAPA and TV-OSL, HOTV-PAPA does not create sizable staircase artifacts. Moreover, HOTV-PAPA effectively suppresses noise, with only limited loss of local spatial resolution. Of the four methods, HOTV-PAPA shows the best lesion detectability, thanks to its superior noise suppression. HOTV-PAPA shows promise for clinically useful reconstructions of low-dose SPECT data.
Collapse
Affiliation(s)
- Si Li
- Guangdong Provincial Key Laboratory of Computational Science, School of Mathematics and Computational Sciences, Sun Yat-sen University, Guangzhou 510275, China
| | - Jiahan Zhang
- Department of Physics, Syracuse University, Syracuse, New York 13244
| | - Andrzej Krol
- Department of Radiology, SUNY Upstate Medical University, Syracuse, New York 13210
| | - C Ross Schmidtlein
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York 10065
| | | | - Lixin Shen
- Guangdong Provincial Key Laboratory of Computational Science, School of Mathematics and Computational Sciences, Sun Yat-sen University, Guangzhou 510275, China and Department of Mathematics, Syracuse University, Syracuse, New York 13244
| | - Edward Lipson
- Department of Physics, Syracuse University, Syracuse, New York 13244
| | - David Feiglin
- Department of Radiology, SUNY Upstate Medical University, Syracuse, New York 13210
| | - Yuesheng Xu
- Guangdong Provincial Key Laboratory of Computational Science, School of Mathematics and Computational Sciences, Sun Yat-sen University, Guangzhou 510275, China
| |
Collapse
|
6
|
Pino F, Roé N, Aguiar P, Falcon C, Ros D, Pavía J. Improved image quality in pinhole SPECT by accurate modeling of the point spread function in low magnification systems. Med Phys 2015; 42:703-14. [PMID: 25652484 DOI: 10.1118/1.4905157] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE Single photon emission computed tomography (SPECT) has become an important noninvasive imaging technique in small-animal research. Due to the high resolution required in small-animal SPECT systems, the spatially variant system response needs to be included in the reconstruction algorithm. Accurate modeling of the system response should result in a major improvement in the quality of reconstructed images. The aim of this study was to quantitatively assess the impact that an accurate modeling of spatially variant collimator/detector response has on image-quality parameters, using a low magnification SPECT system equipped with a pinhole collimator and a small gamma camera. METHODS Three methods were used to model the point spread function (PSF). For the first, only the geometrical pinhole aperture was included in the PSF. For the second, the septal penetration through the pinhole collimator was added. In the third method, the measured intrinsic detector response was incorporated. Tomographic spatial resolution was evaluated and contrast, recovery coefficients, contrast-to-noise ratio, and noise were quantified using a custom-built NEMA NU 4-2008 image-quality phantom. RESULTS A high correlation was found between the experimental data corresponding to intrinsic detector response and the fitted values obtained by means of an asymmetric Gaussian distribution. For all PSF models, resolution improved as the distance from the point source to the center of the field of view increased and when the acquisition radius diminished. An improvement of resolution was observed after a minimum of five iterations when the PSF modeling included more corrections. Contrast, recovery coefficients, and contrast-to-noise ratio were better for the same level of noise in the image when more accurate models were included. Ring-type artifacts were observed when the number of iterations exceeded 12. CONCLUSIONS Accurate modeling of the PSF improves resolution, contrast, and recovery coefficients in the reconstructed images. To avoid the appearance of ring-type artifacts, the number of iterations should be limited. In low magnification systems, the intrinsic detector PSF plays a major role in improvement of the image-quality parameters.
Collapse
Affiliation(s)
- Francisco Pino
- Unitat de Biofísica, Facultat de Medicina, Universitat de Barcelona, Barcelona 08036, Spain and Servei de Física Mèdica i Protecció Radiològica, Institut Català d'Oncologia, L'Hospitalet de Llobregat 08907, Spain
| | - Nuria Roé
- Unitat de Biofísica, Facultat de Medicina, Universitat de Barcelona, Barcelona 08036, Spain
| | - Pablo Aguiar
- Fundación Ramón Domínguez, Complexo Hospitalario Universitario de Santiago de Compostela 15706, Spain and Grupo de Imagen Molecular, Instituto de Investigacións Sanitarias de Santiago de Compostela (IDIS), Galicia 15782, Spain
| | - Carles Falcon
- Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), Barcelona 08036, Spain and CIBER en Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Barcelona 08036, Spain
| | - Domènec Ros
- Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), Barcelona 08036, Spain and CIBER en Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Barcelona 08036, Spain
| | - Javier Pavía
- Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), Barcelona 080836, Spain; CIBER en Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Barcelona 08036, Spain; and Servei de Medicina Nuclear, Hospital Clínic, Barcelona 08036, Spain
| |
Collapse
|