• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4643712)   Today's Articles (431)   Subscriber (50624)
For: Javedan K, Zhang GG, Hoffe S, Feygelman V, Forster K. Comparing dose in the build-up region between compensator- and MLC-based IMRT. J Appl Clin Med Phys 2012;13:3748. [PMID: 22955641 PMCID: PMC5718229 DOI: 10.1120/jacmp.v13i5.3748] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2011] [Revised: 04/16/2012] [Accepted: 04/23/2012] [Indexed: 11/23/2022]  Open
Number Cited by Other Article(s)
1
Sengupta B, Oh K, Sponseller P, Zaki P, Eastman B, Dinh TKT, Cardenas CE, Court LE, Parvathaneni U, Ford E. Cobalt compensator-based IMRT device: A treatment planning study of head and neck cases. Phys Med 2023;106:102526. [PMID: 36621080 PMCID: PMC10468209 DOI: 10.1016/j.ejmp.2023.102526] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/05/2022] [Revised: 12/28/2022] [Accepted: 01/02/2023] [Indexed: 01/08/2023]  Open
2
Mendes BM, Trindade BM, Fonseca TCF, de Campos TPR. Assessment of radiation-induced secondary cancer risk in the Brazilian population from left-sided breast-3D-CRT using MCNPX. Br J Radiol 2017;90:20170187. [PMID: 28937271 PMCID: PMC6047661 DOI: 10.1259/bjr.20170187] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2017] [Revised: 09/06/2017] [Accepted: 09/08/2017] [Indexed: 01/08/2023]  Open
3
Zhang DG, Feygelman V, Moros EG, Latifi K, Hoffe S, Frakes J, Zhang GG. Superficial and peripheral dose in compensator-based FFF beam IMRT. J Appl Clin Med Phys 2016;18:151-156. [PMID: 28291940 PMCID: PMC5689887 DOI: 10.1002/acm2.12018] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2016] [Accepted: 10/28/2016] [Indexed: 11/29/2022]  Open
4
Gates LL, Gladstone DJ. Quantitative analysis of brass compensators for commissioning of the Pinnacle planning system for IMRT. J Appl Clin Med Phys 2015;16:130–138. [PMID: 26699564 PMCID: PMC5690995 DOI: 10.1120/jacmp.v16i6.5531] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2014] [Revised: 08/18/2015] [Accepted: 06/30/2015] [Indexed: 11/23/2022]  Open
5
Javedan K, Feygelman V, Zhang RR, Moros EG, Correa CR, Trotti A, Li W, Zhang GG. Monte Carlo comparison of superficial dose between flattening filter free and flattened beams. Phys Med 2014;30:503-8. [PMID: 24662096 DOI: 10.1016/j.ejmp.2014.03.001] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/12/2013] [Revised: 01/27/2014] [Accepted: 03/03/2014] [Indexed: 10/25/2022]  Open
6
Monte Carlo investigation of the effect of small cutouts on beam profile parameters of 12 and 14 MeV electron beams. RADIAT MEAS 2013. [DOI: 10.1016/j.radmeas.2013.01.019] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA