1
|
GÜN N, KARABOCE B, YURDALAN U. INVESTIGATION OF THERAPEUTIC ULTRASOUND DOSE ON MUSCLE PHANTOM: AN EXPERIMENTAL STUDY. CLINICAL AND EXPERIMENTAL HEALTH SCIENCES 2021. [DOI: 10.33808/clinexphealthsci.950896] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
2
|
Catelani F, Costa-Júnior JFS, de Andrade MC, Von Krüger MA, Pereira WCDA. Recycled windshield glass as new material for producing ultrasonic phantoms of cortical bone-healing stages. Biomed Phys Eng Express 2021; 7. [PMID: 34340223 DOI: 10.1088/2057-1976/ac19ce] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2021] [Accepted: 08/02/2021] [Indexed: 11/11/2022]
Abstract
The quantitative ultrasound technique was used to evaluate bone-mimicking phantoms; however, these phantoms do not mimic the intermediate stages of cortical bone healing. We propose using windshield glass as an original material to produce phantoms that mimic the characteristics of three different stages of cortical bone healing. This material was processed via a route that included breaking, grinding, compacting, drying, and sintering in four temperature groups: 625 °C, 645 °C, 657 °C, and 663 °C. The parameters evaluated were the ultrasonic longitudinal phase velocity (cL), corrected (αc) ultrasonic attenuation coefficient, and bulk density (ρs). The results showed that the mean values ofcL,αc,andρsvaried from 2, 398 to 4, 406 m·s-1, 3 to 10 dB·cm-1, and 1, 563 to 2, 089 kg·m-3, respectively. The phantoms exhibited properties comparable with the three stages of cortical bone healing and can be employed in diagnostic and therapeutic studies using ultrasound.
Collapse
Affiliation(s)
- Fernanda Catelani
- Brazilian Navy, Rio de Janeiro, RJ, Brazil.,Raul Sertã Municipal Hospital, Nova Friburgo, RJ, Brazil.,Biomedical Engineering Program - COPPE, Federal University of Rio de Janeiro, Rio de Janeiro, RJ, Brazil
| | - José Francisco Silva Costa-Júnior
- Biomedical Engineering Program - COPPE, Federal University of Rio de Janeiro, Rio de Janeiro, RJ, Brazil.,Brazilian Air Force Academy, Pirassununga, SP, Brazil
| | | | - Marco Antônio Von Krüger
- Biomedical Engineering Program - COPPE, Federal University of Rio de Janeiro, Rio de Janeiro, RJ, Brazil
| | | |
Collapse
|
3
|
Bakhsh TA. Optical comparison between micro-CT and OCT in imaging of marginal composite adaptation: Observational study. J Microsc 2021; 282:136-145. [PMID: 33236773 DOI: 10.1111/jmi.12988] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2020] [Revised: 10/17/2020] [Accepted: 11/22/2020] [Indexed: 11/30/2022]
Abstract
Dental composite is the most used aesthetic restorative biomaterial worldwide. However, it undergoes polymerisation shrinkage that could lead to loss of the interfacial seal between tooth and resin in some circumstances. This demands high-resolution imaging technologies to detect these defects. This study carried out a comparison between microcomputed tomography (micro-CT; Shimadzu, Japan) and swept-source optical coherence tomography (SS-OCT; Santec, Japan) in the detection of marginal adaptation defects at the tooth-resin interface. Unlike in micro-CT, it was possible to outline interfacial gaps along with tooth-resin interfaces with SS-OCT, which was attributed to the Fresnel diffraction of light. This in vitro comparison demonstrates SS-OCT has great potential in dental imaging to effectively assess dental composite adaptation and marginal defects when high resolution is desired in real time. LAY DESCRIPTION: Detection of tooth-colored restoration defects had been assessed by different radiographic methods. However, most of these methods are either invasive or suffer from low-resolution. In this study, a comparison has been carried out between two different high-resolution imaging systems; microcomputed tomography and optical coherence tomography, to explore their potentials in detecting restorations defects. The results showed optical coherence tomography has a great accuracy in locating the underlying defects when the obtained images were validated against confocal laser scanning microscopy images.
Collapse
Affiliation(s)
- Turki A Bakhsh
- Faculty of Dentistry, Restorative Dentistry Department, King Abdulaziz University, Jeddah, Saudi Arabia.,Department of Restorative Sciences, Cariology and Operative Dentistry, Tokyo Medical and Dental University, Bunkyo-ku, Tokyo, Japan
| |
Collapse
|
4
|
Elvira L, Durán C, Higuti RT, Tiago MM, Ibáñez A, Parrilla M, Valverde E, Jiménez J, Bassat Q. Development and Characterization of Medical Phantoms for Ultrasound Imaging Based on Customizable and Mouldable Polyvinyl Alcohol Cryogel-Based Materials and 3-D Printing: Application to High-Frequency Cranial Ultrasonography in Infants. ULTRASOUND IN MEDICINE & BIOLOGY 2019; 45:2226-2241. [PMID: 31128769 DOI: 10.1016/j.ultrasmedbio.2019.04.030] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/07/2018] [Revised: 04/29/2019] [Accepted: 04/29/2019] [Indexed: 06/09/2023]
Abstract
This work presents an affordable and easily customizable methodology for phantom manufacturing, which can be used to mimic different anatomic organs and structures. This methodology is based on the use of polyvinyl alcohol-based cryogels as a physical substitute for biologic soft tissues and of 3-D printed polymers for hard tissues, moulding and supporting elements. Thin and durable soft-tissue mimicking layers and multilayer arrangements can be obtained using these materials. Special attention was paid to the acoustic properties (sound speed, attenuation coefficient and mechanical impedance) of the materials developed to simulate soft tissues. These properties were characterized as a function of the additives concentration (propylene-glycol and alumina particles). The polyvinyl alcohol formulation proposed in this work is stable over several freeze-thaw cycles, allowing the manufacturing of multilayer materials with controlled properties. The manufacturing methodology presented was applied to the development of a phantom for high-frequency cranial ultrasonography in infants. This phantom was able to reproduce the main characteristics of the ultrasound images obtained in neonates through the anterior fontanel, down to 8-mm depth.
Collapse
Affiliation(s)
- Luis Elvira
- Instituto de Tecnologías Físicas y de la Información, CSIC, Madrid, Spain.
| | - Carmen Durán
- Instituto de Tecnologías Físicas y de la Información, CSIC, Madrid, Spain
| | - Ricardo T Higuti
- Univ Estadual Paulista, Campus of Ilha Solteira, Departament of Electrical Engineering, São Paulo, Brazil
| | - Marcelo M Tiago
- Federal University of Ouro Preto (UFOP), Department of Electrical Engineering, João Monlevade, Minas Gerais, Brazil
| | - Alberto Ibáñez
- Instituto de Tecnologías Físicas y de la Información, CSIC, Madrid, Spain
| | | | - Eva Valverde
- Unidad de Neonatología, Hospital La Paz, Madrid, Spain
| | - Javier Jiménez
- New Born Solutions, Barcelona Scientific Park, Barcelona, Spain
| | - Quique Bassat
- ISGlobal, Hospital Clínic - Universitat de Barcelona, Barcelona, Spain; Centro de Investigação em Saúde de Manhiça (CISM), Maputo, Mozambique; ICREA, Pg. Lluís Companys 23, Barcelona, Spain; Pediatric Infectious Diseases Unit, Pediatrics Department, Hospital Sant Joan de Déu (University of Barcelona), Barcelona, Spain
| |
Collapse
|
5
|
Kim D, Park SH. A Microfluidics-based Pulpal Arteriole Blood Flow Phantom for Validation of Doppler Ultrasound Devices in Pulpal Blood Flow Velocity Measurement. J Endod 2016; 42:1660-1666. [DOI: 10.1016/j.joen.2016.08.008] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2016] [Revised: 08/09/2016] [Accepted: 08/09/2016] [Indexed: 10/21/2022]
|
6
|
Tiong TJ, Low LE, Teoh HJ, Chin JK, Manickam S. Variation in performance at different positions of an ultrasonic VialTweeter--A study based on various physical and chemical activities. ULTRASONICS SONOCHEMISTRY 2015; 27:165-170. [PMID: 26186833 DOI: 10.1016/j.ultsonch.2015.04.033] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/01/2014] [Revised: 04/02/2015] [Accepted: 04/28/2015] [Indexed: 06/04/2023]
Abstract
Ultrasonic VialTweeter is used for the sonication of small volume samples. It contains a titanium block with 8 holes for vial insertion, to be used simultaneously for batch operation. In this investigation, the ultrasonic and sonochemical performance of ultrasonic VialTweeter has been evaluated at its different positions. Experimental results using calorimetry, ultrasonic capillary effect, sonochemiluminescence and degradation of Rhodamine B showed that the sonochemical activity differs greatly at different positions along the VialTweeter, with positions 3 and 4 showing the maximum efficiency whereas the positions 1 and 2 being the least effective positions. These results were further verified by acoustic pressure simulation, confirming that certain locations in the VialTweeter may not perform in the same way as others due to the variation in acoustic pressure at different locations.
Collapse
Affiliation(s)
- T Joyce Tiong
- Manufacturing and Industrial Processes Research Division, Faculty of Engineering, University of Nottingham Malaysia Campus, 43500 Semenyih, Selangor, Malaysia; Department of Chemical and Environmental Engineering, Faculty of Engineering, University of Nottingham Malaysia Campus, 43500 Semenyih, Selangor, Malaysia.
| | - Liang Ee Low
- Department of Chemical and Environmental Engineering, Faculty of Engineering, University of Nottingham Malaysia Campus, 43500 Semenyih, Selangor, Malaysia
| | - Hui Jiun Teoh
- Department of Chemical and Environmental Engineering, Faculty of Engineering, University of Nottingham Malaysia Campus, 43500 Semenyih, Selangor, Malaysia
| | - Jit-Kai Chin
- Department of Chemical and Environmental Engineering, Faculty of Engineering, University of Nottingham Malaysia Campus, 43500 Semenyih, Selangor, Malaysia
| | - Sivakumar Manickam
- Manufacturing and Industrial Processes Research Division, Faculty of Engineering, University of Nottingham Malaysia Campus, 43500 Semenyih, Selangor, Malaysia; Department of Chemical and Environmental Engineering, Faculty of Engineering, University of Nottingham Malaysia Campus, 43500 Semenyih, Selangor, Malaysia
| |
Collapse
|
7
|
Tiong TJ, Price GJ, Kanagasingam S. A computational simulation study on the acoustic pressure generated by a dental endosonic file: effects of intensity, file shape and volume. ULTRASONICS SONOCHEMISTRY 2014; 21:1858-1865. [PMID: 24735986 DOI: 10.1016/j.ultsonch.2014.03.024] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/02/2013] [Revised: 02/18/2014] [Accepted: 03/24/2014] [Indexed: 06/03/2023]
Abstract
One of the uses of ultrasound in dentistry is in the field of endodontics (i.e. root canal treatment) in order to enhance cleaning efficiency during the treatment. The acoustic pressures generated by the oscillation of files in narrow channels has been calculated using the COMSOL simulation package. Acoustic pressures in excess of the cavitation threshold can be generated and higher values were found in narrower channels. This parallels experimental observations of sonochemiluminescence. The effect of varying the channel width and length and the dimensions and shape of the file are reported. As well as explaining experimental observations, the work provides a basis for the further development and optimisation of the design of endosonic files.
Collapse
Affiliation(s)
- T Joyce Tiong
- Manufacturing and Industrial Processes Research Division, Faculty of Engineering, University of Nottingham Malaysia Campus, 43500 Semenyih, Selangor, Malaysia.
| | - Gareth J Price
- Department of Chemistry, University of Bath, Claverton Down, Bath BA2 7AY, United Kingdom
| | - Shalini Kanagasingam
- Department of Dentistry, Universiti Kebangsaan Malaysia, Jalan Raja Muda Abdul Aziz, 50300 Kuala Lumpur, Malaysia
| |
Collapse
|
8
|
John C, Löst C, ElAyouti A. Ultrasonic monitoring of the effect of sodium hypochlorite on the elasticity of dentine. Int Endod J 2012; 46:477-82. [DOI: 10.1111/iej.12015] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2012] [Accepted: 09/05/2012] [Indexed: 12/01/2022]
Affiliation(s)
- C. John
- Division of Endodontology; Department of Conservative Dentistry; University of Tübingen; Tübingen; Germany
| | - C. Löst
- Division of Endodontology; Department of Conservative Dentistry; University of Tübingen; Tübingen; Germany
| | - A. ElAyouti
- Division of Endodontology; Department of Conservative Dentistry; University of Tübingen; Tübingen; Germany
| |
Collapse
|
9
|
Harput S, Evans T, Bubb N, Freear S. Diagnostic ultrasound tooth imaging using fractional Fourier transform. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2011; 58:2096-2106. [PMID: 21989873 DOI: 10.1109/tuffc.2011.2059] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
An ultrasound contact imaging method is proposed to measure the enamel thickness in the human tooth. A delay-line transducer with a working frequency of 15 MHz is chosen to achieve a minimum resolvable distance of 400 μm in human enamel. To confirm the contact between the tooth and the transducer, a verification technique based on the phase shift upon reflection is used. Because of the high attenuation in human teeth, linear frequency-modulated chirp excitation and pulse compression are exploited to increase the penetration depth and improve the SNR. Preliminary measurements show that the enamel-dentin boundary creates numerous internal reflections, which cause the applied chirp signals to interfere arbitrarily. In this work, the fractional Fourier transform (FrFT) is employed for the first time in dental imaging to separate chirp signals overlapping in both time and frequency domains. The overlapped chirps are compressed using the FrFT and matched filter techniques. Micro-computed tomography is used for validation of the ultrasound measurements for both techniques. For a human molar, the thickness of the enamel layer is measured with an average error of 5.5% after compressing with the FrFT and 13.4% after compressing with the matched filter based on the average speed of sound in human teeth.
Collapse
Affiliation(s)
- Sevan Harput
- Ultrasound Group, School of Electronic and Electrical Engineering, University of Leeds, Leeds, UK.
| | | | | | | |
Collapse
|
10
|
Culjat MO, Goldenberg D, Tewari P, Singh RS. A review of tissue substitutes for ultrasound imaging. ULTRASOUND IN MEDICINE & BIOLOGY 2010; 36:861-73. [PMID: 20510184 DOI: 10.1016/j.ultrasmedbio.2010.02.012] [Citation(s) in RCA: 337] [Impact Index Per Article: 22.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/30/2009] [Revised: 02/03/2010] [Accepted: 02/22/2010] [Indexed: 05/05/2023]
Abstract
The characterization and calibration of ultrasound imaging systems requires tissue-mimicking phantoms with known acoustic properties, dimensions and internal features. Tissue phantoms are available commercially for a range of medical applications. However, commercial phantoms may not be suitable in ultrasound system design or for evaluation of novel imaging techniques. It is often desirable to have the ability to tailor acoustic properties and phantom configurations for specific applications. A multitude of tissue-mimicking materials and phantoms are described in the literature that have been created using a variety of materials and preparation techniques and that have modeled a range of biological systems. This paper reviews ultrasound tissue-mimicking materials and phantom fabrication techniques that have been developed over the past four decades, and describes the benefits and disadvantages of the processes. Both soft tissue and hard tissue substitutes are explored.
Collapse
Affiliation(s)
- Martin O Culjat
- Center for Advanced Surgical and Interventional Technology (CASIT), UCLA, Los Angeles, CA, USA.
| | | | | | | |
Collapse
|
11
|
Casciaro S, Conversano F, Musio S, Casciaro E, Demitri C, Sannino A. Full experimental modelling of a liver tissue mimicking phantom for medical ultrasound studies employing different hydrogels. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2009; 20:983-989. [PMID: 19052848 DOI: 10.1007/s10856-008-3644-6] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/05/2008] [Accepted: 11/03/2008] [Indexed: 05/27/2023]
Abstract
Tissue mimicking phantoms have been widely reported to be an important tool for development, optimisation and performance testing of ultrasound-based diagnostic techniques. In particular, modern applications of tissue mimicking phantoms often include characterisation of the nonlinear behaviour of experimental ultrasound contrast agents. In such cases, the tissue-mimicking materials should be chosen not only based on the values of their density, speed of sound and attenuation coefficient, but also considering their effect on the appearance of "native harmonics" due to nonlinear distortion of ultrasound signal during propagation. In a previous paper it was demonstrated that a cellulose-based hydrogel is suitable to simulate nonlinear acoustical behaviour of liver tissue for thicknesses up to 8 cm. In this paper we present the experimental characterisation of the nonlinear acoustical behaviour of a different polyethylene glycol diacrylate (PEGDA)-based hydrogel, in order to assess whether and how it can improve the performances and overcome some limitations of the cellulose-based hydrogel as liver tissue-mimicking material. Samples of pig liver tissue, cellulose-based hydrogel and PEGDA-based hydrogel were insonified in a through-transmission set-up, employing 2.25-MHz pulses with different mechanical index (MI) values. Second harmonic and first harmonic amplitudes were extracted from the spectra of received signals and their difference was then used to compare sample behaviours. Obtained results show how a new more accurate and combined experimental model of linear and nonlinear acoustical behaviour of liver tissue is feasible. In fact, a further confirmation of the cellulose-based hydrogel effectiveness to precisely simulate the liver tissue for penetration depths up to 8 cm was provided, and it was also shown that the employment of the PEGDA-based hydrogel can extend the range of useful tissue-mimicking material thicknesses up to 11 cm, moreover allowing a considerable improvement of the time stability and behaviour reliability of the corresponding manufactured phantoms.
Collapse
Affiliation(s)
- Sergio Casciaro
- Institute of Clinical Physiology, National Council of Research (IFC-CNR), c/o Campus Ecotekne, via per Monteroni, 73100, Lecce, Italy.
| | | | | | | | | | | |
Collapse
|