1
|
Li S, Zhou Z, Wu S, Wu W. A Review of Quantitative Ultrasound-Based Approaches to Thermometry and Ablation Zone Identification Over the Past Decade. ULTRASONIC IMAGING 2022; 44:213-228. [PMID: 35993226 DOI: 10.1177/01617346221120069] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Percutaneous thermal therapy is an important clinical treatment method for some solid tumors. It is critical to use effective image visualization techniques to monitor the therapy process in real time because precise control of the therapeutic zone directly affects the prognosis of tumor treatment. Ultrasound is used in thermal therapy monitoring because of its real-time, non-invasive, non-ionizing radiation, and low-cost characteristics. This paper presents a review of nine quantitative ultrasound-based methods for thermal therapy monitoring and their advances over the last decade since 2011. These methods were analyzed and compared with respect to two applications: ultrasonic thermometry and ablation zone identification. The advantages and limitations of these methods were compared and discussed, and future developments were suggested.
Collapse
Affiliation(s)
- Sinan Li
- Department of Biomedical Engineering, Faculty of Environment and Life, Beijing University of Technology, Beijing, China
| | - Zhuhuang Zhou
- Department of Biomedical Engineering, Faculty of Environment and Life, Beijing University of Technology, Beijing, China
| | - Shuicai Wu
- Department of Biomedical Engineering, Faculty of Environment and Life, Beijing University of Technology, Beijing, China
| | - Weiwei Wu
- College of Biomedical Engineering, Capital Medical University, Beijing, China
| |
Collapse
|
2
|
Ghahramani Z E, Grimm PD, Eary KJ, Swearengen MP, Dayavansha EGSK, Mast TD. Three-dimensional echo decorrelation monitoring of radiofrequency ablation in ex vivo bovine liver. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2022; 151:3907. [PMID: 35778168 PMCID: PMC9187351 DOI: 10.1121/10.0011641] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/07/2022] [Revised: 05/14/2022] [Accepted: 05/23/2022] [Indexed: 06/03/2023]
Abstract
Three-dimensional (3D) echo decorrelation imaging was investigated for monitoring radiofrequency ablation (RFA) in ex vivo bovine liver. RFA experiments (N = 14) were imaged by 3D ultrasound using a matrix array, with in-phase and quadrature complex echo volumes acquired about every 11 s. Tissue specimens were then frozen at -80 °C, sectioned, and semi-automatically segmented. Receiver operating characteristic (ROC) curves were constructed for assessing ablation prediction performance of 3D echo decorrelation with three potential normalization approaches, as well as 3D integrated backscatter (IBS). ROC analysis indicated that 3D echo decorrelation imaging is potentially a good predictor of local RFA, with the best prediction performance observed for globally normalized decorrelation. Tissue temperatures, recorded by four thermocouples integrated into the RFA probe, showed good correspondence with spatially averaged decorrelation and statistically significant but weak correlation with measured echo decorrelation at the same spatial locations. In tests predicting ablation zones using a weighted K-means clustering approach, echo decorrelation performed better than IBS, with smaller root mean square volume errors and higher Dice coefficients relative to measured ablation zones. These results suggest that 3D echo decorrelation and IBS imaging are capable of real-time monitoring of thermal ablation, with potential application to clinical treatment of liver tumors.
Collapse
Affiliation(s)
- E Ghahramani Z
- Department of Biomedical Engineering, University of Cincinnati, Ohio 45267-0586, USA
| | - P D Grimm
- Department of Biomedical Engineering, University of Cincinnati, Ohio 45267-0586, USA
| | - K J Eary
- Department of Biomedical Engineering, University of Cincinnati, Ohio 45267-0586, USA
| | - M P Swearengen
- Department of Biomedical Engineering, University of Cincinnati, Ohio 45267-0586, USA
| | | | - T D Mast
- Department of Biomedical Engineering, University of Cincinnati, Ohio 45267-0586, USA
| |
Collapse
|
3
|
Cox MT, Abbass MA, Mast TD. Numerical analysis of three-dimensional echo decorrelation imaging. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2020; 147:EL478. [PMID: 32611173 PMCID: PMC7275868 DOI: 10.1121/10.0001334] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
A numerical model for three-dimensional echo decorrelation imaging, a pulse-echo ultrasound method applicable to thermal ablation monitoring, is presented. Beam patterns for steered transmit and receive array apertures are combined with a three-dimensional numerical tissue model to yield beamformed scan lines in a pyramidal configuration, volumetric B-mode images, and spatial maps of normalized decorrelation between sequential image volumes. Simulated three-dimensional echo decorrelation images of random media are analyzed as estimators of local tissue reflectivity decoherence, mimicking thermal ablation effects. The estimation error is analyzed as a function of correlation window size, scan line density, and ensemble averaging of decorrelation maps.
Collapse
Affiliation(s)
- Michael T Cox
- Department of Biomedical Engineering, University of Cincinnati, Cincinnati, Ohio 45267, , ,
| | - Mohamed A Abbass
- Department of Biomedical Engineering, University of Cincinnati, Cincinnati, Ohio 45267, , ,
| | - T Douglas Mast
- Department of Biomedical Engineering, University of Cincinnati, Cincinnati, Ohio 45267, , ,
| |
Collapse
|
4
|
Abbass MA, Ahmad SA, Mahalingam N, Krothapalli KS, Masterson JA, Rao MB, Barthe PG, Mast TD. In vivo ultrasound thermal ablation control using echo decorrelation imaging in rabbit liver and VX2 tumor. PLoS One 2019; 14:e0226001. [PMID: 31805129 PMCID: PMC6894854 DOI: 10.1371/journal.pone.0226001] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2019] [Accepted: 11/18/2019] [Indexed: 12/21/2022] Open
Abstract
The utility of echo decorrelation imaging feedback for real-time control of in vivo ultrasound thermal ablation was assessed in rabbit liver with VX2 tumor. High-intensity focused ultrasound (HIFU) and unfocused (bulk) ablation were performed using 5 MHz linear image-ablate arrays. Treatments comprised up to nine lower-power sonications, followed by up to nine higher-power sonications, ceasing when the average cumulative echo decorrelation within a control region of interest exceeded a predefined threshold (- 2.3, log10-scaled echo decorrelation per millisecond, corresponding to 90% specificity for tumor ablation prediction in previous in vivo experiments). This threshold was exceeded in all cases for both HIFU (N = 12) and bulk (N = 8) ablation. Controlled HIFU trials achieved a significantly higher average ablation rate compared to comparable ablation trials without image-based control, reported previously. Both controlled HIFU and bulk ablation trials required significantly less treatment time than these previous uncontrolled trials. Prediction of local liver and VX2 tumor ablation using echo decorrelation was tested using receiver operator characteristic curve analysis, showing prediction capability statistically equivalent to uncontrolled trials. Compared to uncontrolled trials, controlled trials resulted in smaller thermal ablation regions and higher contrast between echo decorrelation in treated vs. untreated regions. These results indicate that control using echo decorrelation imaging may reduce treatment duration and increase treatment reliability for in vivo thermal ablation.
Collapse
Affiliation(s)
- Mohamed A. Abbass
- Dept of Biomedical Engineering, University of Cincinnati, Cincinnati, Ohio, United States of America
| | - Syed A. Ahmad
- Dept of Surgery, University of Cincinnati, Cincinnati, Ohio, United States of America
| | - Neeraja Mahalingam
- Dept of Biomedical Engineering, University of Cincinnati, Cincinnati, Ohio, United States of America
| | - K. Sameer Krothapalli
- Dept of Biomedical Engineering, University of Cincinnati, Cincinnati, Ohio, United States of America
| | - Jack A. Masterson
- Dept of Biomedical Engineering, University of Cincinnati, Cincinnati, Ohio, United States of America
| | - Marepalli B. Rao
- Dept of Biomedical Engineering, University of Cincinnati, Cincinnati, Ohio, United States of America
- Dept of Environmental Health, University of Cincinnati, Cincinnati, Ohio, United States of America
| | - Peter G. Barthe
- Guided Therapy Systems/Ardent Sound, Mesa, Arizona, United States of America
| | - T. Douglas Mast
- Dept of Biomedical Engineering, University of Cincinnati, Cincinnati, Ohio, United States of America
| |
Collapse
|
5
|
Zhou Z, Wang Y, Song S, Wu W, Wu S, Tsui PH. Monitoring Microwave Ablation Using Ultrasound Echo Decorrelation Imaging: An ex vivo Study. SENSORS (BASEL, SWITZERLAND) 2019; 19:E977. [PMID: 30823609 PMCID: PMC6412341 DOI: 10.3390/s19040977] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/21/2019] [Revised: 02/17/2019] [Accepted: 02/21/2019] [Indexed: 12/19/2022]
Abstract
In this study, a microwave-induced ablation zone (thermal lesion) monitoring method based on ultrasound echo decorrelation imaging was proposed. A total of 15 cases of ex vivo porcine liver microwave ablation (MWA) experiments were carried out. Ultrasound radiofrequency (RF) signals at different times during MWA were acquired using a commercial clinical ultrasound scanner with a 7.5-MHz linear-array transducer. Instantaneous and cumulative echo decorrelation images of two adjacent frames of RF data were calculated. Polynomial approximation images were obtained on the basis of the thresholded cumulative echo decorrelation images. Experimental results showed that the instantaneous echo decorrelation images outperformed conventional B-mode images in monitoring microwave-induced thermal lesions. Using gross pathology measurements as the reference standard, the estimation of thermal lesions using the polynomial approximation images yielded an average accuracy of 88.60%. We concluded that instantaneous ultrasound echo decorrelation imaging is capable of monitoring the change of thermal lesions during MWA, and cumulative ultrasound echo decorrelation imaging and polynomial approximation imaging are feasible for quantitatively depicting thermal lesions.
Collapse
Affiliation(s)
- Zhuhuang Zhou
- College of Life Science and Bioengineering, Beijing University of Technology, Beijing 100124, China.
| | - Yue Wang
- College of Life Science and Bioengineering, Beijing University of Technology, Beijing 100124, China.
| | - Shuang Song
- College of Life Science and Bioengineering, Beijing University of Technology, Beijing 100124, China.
| | - Weiwei Wu
- College of Biomedical Engineering, Capital Medical University, Beijing 100054, China.
| | - Shuicai Wu
- College of Life Science and Bioengineering, Beijing University of Technology, Beijing 100124, China.
| | - Po-Hsiang Tsui
- Department of Medical Imaging and Radiological Sciences, College of Medicine, Chang Gung University, Taoyuan 33302, Taiwan.
- Medical Imaging Research Center, Institute for Radiological Research, Chang Gung University and Chang Gung Memorial Hospital at Linkou, Taoyuan 33302, Taiwan.
- Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital at Linkou, Taoyuan 33302, Taiwan.
| |
Collapse
|
6
|
Abbass MA, Garbo AJ, Mahalingam N, Killin JK, Mast TD. Optimized Echo Decorrelation Imaging Feedback for Bulk Ultrasound Ablation Control. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2018; 65:1743-1755. [PMID: 29994657 PMCID: PMC6294441 DOI: 10.1109/tuffc.2018.2847599] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/02/2023]
Abstract
Feasibility of controlling bulk ultrasound (US) thermal ablation using echo decorrelation imaging was investigated in ex vivo bovine liver. The first of two ablation and control procedures used a sequence of constant-intensity sonication cycles, ceased when the minimum echo decorrelation within a control region of interest (ROI) exceeded a predetermined threshold. The second procedure used a variable-intensity sonication sequence, with spatially averaged decorrelation as the stopping criterion. US exposures and echo decorrelation imaging were performed by a linear image-ablate array. Based on preliminary experiments, control ROIs and thresholds for the minimum-decorrelation and average-decorrelation criteria were specified. Controlled trials for the minimum-decorrelation and average-decorrelation criteria were compared with uncontrolled trials employing 9 or 18 cycles of matching sonication sequences. Lesion dimensions, treatment times, ablation rates, and areas under receiver operating characteristic curves were statistically compared. Successfully controlled trials using both criteria required significantly shorter treatment times than corresponding 18-cycle treatments, with better ablation prediction performance than uncontrolled 9-cycle and 18-cycle treatments. Either control approach resulted in greater ablation rate than corresponding 9-cycle or 18-cycle uncontrolled approaches. A post hoc analysis studied the effect of exchanging control criteria between the two series of controlled experiments. For either group, the average time needed to exceed the alternative decorrelation threshold approximately matched the average duration of successfully controlled experimental trials. These results indicate that either approach, using minimum-decorrelation or average-decorrelation criteria, is feasible for control of bulk US ablation. In addition, use of a variable-intensity sonication sequence for bulk US thermal ablation can result in larger ablated regions compared to constant-intensity sonication sequences.
Collapse
|
7
|
Abbass MA, Killin JK, Mahalingam N, Hooi FM, Barthe PG, Mast TD. Real-Time Spatiotemporal Control of High-Intensity Focused Ultrasound Thermal Ablation Using Echo Decorrelation Imaging in ex Vivo Bovine Liver. ULTRASOUND IN MEDICINE & BIOLOGY 2018; 44:199-213. [PMID: 29074273 PMCID: PMC5712268 DOI: 10.1016/j.ultrasmedbio.2017.09.007] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/04/2017] [Revised: 08/28/2017] [Accepted: 09/07/2017] [Indexed: 05/05/2023]
Abstract
The ability to control high-intensity focused ultrasound (HIFU) thermal ablation using echo decorrelation imaging feedback was evaluated in ex vivo bovine liver. Sonications were automatically ceased when the minimum cumulative echo decorrelation within the region of interest exceeded an ablation control threshold, determined from preliminary experiments as -2.7 (log-scaled decorrelation per millisecond), corresponding to 90% specificity for local ablation prediction. Controlled HIFU thermal ablation experiments were compared with uncontrolled experiments employing two, five or nine sonication cycles. Means and standard errors of the lesion width, area and depth, as well as receiver operating characteristic curves testing ablation prediction performance, were computed for each group. Controlled trials exhibited significantly smaller average lesion area, width and treatment time than five-cycle or nine-cycle uncontrolled trials and also had significantly greater prediction capability than two-cycle uncontrolled trials. These results suggest echo decorrelation imaging is an effective approach to real-time HIFU ablation control.
Collapse
Affiliation(s)
- Mohamed A Abbass
- Biomedical Engineering, University of Cincinnati, Cincinnati, Ohio, USA
| | - Jakob K Killin
- Biomedical Engineering, University of Cincinnati, Cincinnati, Ohio, USA
| | | | - Fong Ming Hooi
- Ultrasound Division, Siemens Healthcare, Issaquah, Washington, USA
| | | | - T Douglas Mast
- Biomedical Engineering, University of Cincinnati, Cincinnati, Ohio, USA.
| |
Collapse
|
8
|
Fosnight TR, Hooi FM, Keil RD, Ross AP, Subramanian S, Akinyi TG, Killin JK, Barthe PG, Rudich SM, Ahmad SA, Rao MB, Mast TD. Echo Decorrelation Imaging of Rabbit Liver and VX2 Tumor during In Vivo Ultrasound Ablation. ULTRASOUND IN MEDICINE & BIOLOGY 2017; 43:176-186. [PMID: 27712923 PMCID: PMC5140680 DOI: 10.1016/j.ultrasmedbio.2016.08.025] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/08/2016] [Revised: 08/18/2016] [Accepted: 08/21/2016] [Indexed: 05/05/2023]
Abstract
In open surgical procedures, image-ablate ultrasound arrays performed thermal ablation and imaging on rabbit liver lobes with implanted VX2 tumor. Treatments included unfocused (bulk ultrasound ablation, N = 10) and focused (high-intensity focused ultrasound ablation, N = 13) exposure conditions. Echo decorrelation and integrated backscatter images were formed from pulse-echo data recorded during rest periods after each therapy pulse. Echo decorrelation images were corrected for artifacts using decorrelation measured prior to ablation. Ablation prediction performance was assessed using receiver operating characteristic curves. Results revealed significantly increased echo decorrelation and integrated backscatter in both ablated liver and ablated tumor relative to unablated tissue, with larger differences observed in liver than in tumor. For receiver operating characteristic curves computed from all ablation exposures, both echo decorrelation and integrated backscatter predicted liver and tumor ablation with statistically significant success, and echo decorrelation was significantly better as a predictor of liver ablation. These results indicate echo decorrelation imaging is a successful predictor of local thermal ablation in both normal liver and tumor tissue, with potential for real-time therapy monitoring.
Collapse
Affiliation(s)
- Tyler R Fosnight
- Biomedical Engineering, University of Cincinnati, Cincinnati, Ohio, USA
| | - Fong Ming Hooi
- Biomedical Engineering, University of Cincinnati, Cincinnati, Ohio, USA
| | - Ryan D Keil
- Biomedical Engineering, University of Cincinnati, Cincinnati, Ohio, USA
| | - Alexander P Ross
- Biomedical Engineering, University of Cincinnati, Cincinnati, Ohio, USA
| | | | - Teckla G Akinyi
- Biomedical Engineering, University of Cincinnati, Cincinnati, Ohio, USA
| | - Jakob K Killin
- Biomedical Engineering, University of Cincinnati, Cincinnati, Ohio, USA
| | | | | | - Syed A Ahmad
- Surgery, University of Cincinnati, Cincinnati, Ohio, USA
| | - Marepalli B Rao
- Biomedical Engineering, University of Cincinnati, Cincinnati, Ohio, USA; Environmental Health, University of Cincinnati, Cincinnati, Ohio, USA
| | - T Douglas Mast
- Biomedical Engineering, University of Cincinnati, Cincinnati, Ohio, USA.
| |
Collapse
|
9
|
Subramanian S, Schmidt DT, Rao MB, Mast TD. Dependence of ultrasound echo decorrelation on local tissue temperature during ex vivo radiofrequency ablation. Phys Med Biol 2016; 61:2356-71. [PMID: 26943026 DOI: 10.1088/0031-9155/61/6/2356] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
This study investigates echo decorrelation imaging, an ultrasound method for thermal ablation monitoring. The effect of tissue temperature on the mapped echo decorrelation parameter was assessed in radiofrequency ablation experiments performed on ex vivo bovine liver tissue. Echo decorrelation maps were compared with corresponding tissue temperatures simulated using the finite element method. For both echo decorrelation imaging and integrated backscatter imaging, the mapped tissue parameters correlated significantly but weakly with local tissue temperature. Receiver operating characteristic (ROC) curves were used to assess the ability of echo decorrelation and integrated backscatter to predict tissue temperature greater than 40, 60, and 80 °C. Significantly higher area under the ROC curve (AUROC) values were obtained for prediction of tissue temperatures greater than 40, 60, and 80 °C using echo decorrelation imaging (AUROC = 0.871, 0.948 and 0.966) compared to integrated backscatter imaging (AUROC = 0.865, 0.877 and 0.832).
Collapse
Affiliation(s)
- Swetha Subramanian
- Department of Biomedical, Chemical, and Environmental Engineering, University of Cincinnati, Cincinnati, OH, USA
| | | | | | | |
Collapse
|