1
|
Gühring L, Tur B, Semmler M, Schützenberger A, Kniesburges S. Influence of flow rate and fiber tension on dynamical, mechanical and acoustical parameters in a synthetic larynx model with integrated fibers. Front Physiol 2024; 15:1455360. [PMID: 39628941 PMCID: PMC11611813 DOI: 10.3389/fphys.2024.1455360] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2024] [Accepted: 11/04/2024] [Indexed: 12/06/2024] Open
Abstract
Introduction The human voice is generated by the oscillation of the vocal folds induced by exhalation airflow. Consequently, the characteristics of these oscillations and the primary sound signal are controlled by the longitudinal tension of the vocal folds, the flow rate, and their prephonatoric position. To facilitate independent control of these parameters, a synthetic larynx model was developed, as detailed in a previous publication. Methods This study aims to statistically analyze the influence of airflow and fiber tension on phonation characteristics, such as periodicity and symmetry, glottis closure during vocal fold oscillations, as well as tissue elasticity and generated sound. A total of 76 experiments were conducted and statistically analyzed with a systematic variation of flow rate and longitudinal tension within the vocal folds.During these experiments, vocal fold motion, subglottal pressure, and emitted sound were meticulously measured and analyzed. Results Groupwise statistical testing identified the flow rate as the main influencing parameter on nearly all phonation characteristics. However, the fundamental frequency, stiffness parameters, and quality parameters of the primary sound signal are predominantly controlled by the longitudinal tension within the vocal folds. Discussion The results demonstrated a complex interplay between the flow rate and tension, resulting in different characteristics of the produced sound signal.
Collapse
Affiliation(s)
| | | | | | | | - Stefan Kniesburges
- Department of Otorhinolaryngology, Medical School, Division of Phoniatrics and Pediatric Audiology, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Head and Neck Surgery, University Hospital Erlangen, Erlangen, Waldstrasse, Germany
| |
Collapse
|
2
|
Näger C, Kniesburges S, Tur B, Schoder S, Becker S. An Investigation of Acoustic Back-Coupling in Human Phonation on a Synthetic Larynx Model. Bioengineering (Basel) 2023; 10:1343. [PMID: 38135934 PMCID: PMC10740801 DOI: 10.3390/bioengineering10121343] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2023] [Revised: 11/12/2023] [Accepted: 11/19/2023] [Indexed: 12/24/2023] Open
Abstract
In the human phonation process, acoustic standing waves in the vocal tract can influence the fluid flow through the glottis as well as vocal fold oscillation. To investigate the amount of acoustic back-coupling, the supraglottal flow field has been recorded via high-speed particle image velocimetry (PIV) in a synthetic larynx model for several configurations with different vocal tract lengths. Based on the obtained velocity fields, acoustic source terms were computed. Additionally, the sound radiation into the far field was recorded via microphone measurements and the vocal fold oscillation via high-speed camera recordings. The PIV measurements revealed that near a vocal tract resonance frequency fR, the vocal fold oscillation frequency fo (and therefore also the flow field's fundamental frequency) jumps onto fR. This is accompanied by a substantial relative increase in aeroacoustic sound generation efficiency. Furthermore, the measurements show that fo-fR-coupling increases vocal efficiency, signal-to-noise ratio, harmonics-to-noise ratio and cepstral peak prominence. At the same time, the glottal volume flow needed for stable vocal fold oscillation decreases strongly. All of this results in an improved voice quality and phonation efficiency so that a person phonating with fo-fR-coupling can phonate longer and with better voice quality.
Collapse
Affiliation(s)
- Christoph Näger
- Institute of Fluid Mechanics, Friedrich-Alexander-Universität Erlangen-Nürnberg, Cauerstraße 4, 91058 Erlangen, Germany;
| | - Stefan Kniesburges
- Division of Phoniatrics and Pediatric Audiology, Department of Otorhinolaryngology, Head & Neck Surgery, University Hospital Erlangen, Medical School, Friedrich-Alexander-Universität Erlangen-Nürnberg, Waldstrasse 1, 91054 Erlangen, Germany
| | - Bogac Tur
- Division of Phoniatrics and Pediatric Audiology, Department of Otorhinolaryngology, Head & Neck Surgery, University Hospital Erlangen, Medical School, Friedrich-Alexander-Universität Erlangen-Nürnberg, Waldstrasse 1, 91054 Erlangen, Germany
| | - Stefan Schoder
- Aeroacoustics and Vibroacoustics Group, Institute of Fundamentals and Theory in Electrical Engineering, Graz University of Technology, Inffeldgasse 16, 8010 Graz, Austria;
| | - Stefan Becker
- Institute of Fluid Mechanics, Friedrich-Alexander-Universität Erlangen-Nürnberg, Cauerstraße 4, 91058 Erlangen, Germany;
| |
Collapse
|
3
|
Tur B, Gühring L, Wendler O, Schlicht S, Drummer D, Kniesburges S. Effect of Ligament Fibers on Dynamics of Synthetic, Self-Oscillating Vocal Folds in a Biomimetic Larynx Model. Bioengineering (Basel) 2023; 10:1130. [PMID: 37892860 PMCID: PMC10604794 DOI: 10.3390/bioengineering10101130] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2023] [Revised: 09/13/2023] [Accepted: 09/25/2023] [Indexed: 10/29/2023] Open
Abstract
Synthetic silicone larynx models are essential for understanding the biomechanics of physiological and pathological vocal fold vibrations. The aim of this study is to investigate the effects of artificial ligament fibers on vocal fold vibrations in a synthetic larynx model, which is capable of replicating physiological laryngeal functions such as elongation, abduction, and adduction. A multi-layer silicone model with different mechanical properties for the musculus vocalis and the lamina propria consisting of ligament and mucosa was used. Ligament fibers of various diameters and break resistances were cast into the vocal folds and tested at different tension levels. An electromechanical setup was developed to mimic laryngeal physiology. The measurements included high-speed video recordings of vocal fold vibrations, subglottal pressure and acoustic. For the evaluation of the vibration characteristics, all measured values were evaluated and compared with parameters from ex and in vivo studies. The fundamental frequency of the synthetic larynx model was found to be approximately 200-520 Hz depending on integrated fiber types and tension levels. This range of the fundamental frequency corresponds to the reproduction of a female normal and singing voice range. The investigated voice parameters from vocal fold vibration, acoustics, and subglottal pressure were within normal value ranges from ex and in vivo studies. The integration of ligament fibers leads to an increase in the fundamental frequency with increasing airflow, while the tensioning of the ligament fibers remains constant. In addition, a tension increase in the fibers also generates a rise in the fundamental frequency delivering the physiological expectation of the dynamic behavior of vocal folds.
Collapse
Affiliation(s)
- Bogac Tur
- Division of Phoniatrics and Pediatric Audiology, Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Erlangen, Medical School, Friedrich-Alexander-Universität Erlangen-Nürnberg, Waldstrasse 1, 91054 Erlangen, Germany
| | - Lucia Gühring
- Division of Phoniatrics and Pediatric Audiology, Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Erlangen, Medical School, Friedrich-Alexander-Universität Erlangen-Nürnberg, Waldstrasse 1, 91054 Erlangen, Germany
| | - Olaf Wendler
- Division of Phoniatrics and Pediatric Audiology, Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Erlangen, Medical School, Friedrich-Alexander-Universität Erlangen-Nürnberg, Waldstrasse 1, 91054 Erlangen, Germany
| | - Samuel Schlicht
- Institute of Polymer Technology, Friedrich-Alexander-Universität Erlangen-Nürnberg, Am Weichselgarten 10, 91058 Erlangen, Germany
| | - Dietmar Drummer
- Institute of Polymer Technology, Friedrich-Alexander-Universität Erlangen-Nürnberg, Am Weichselgarten 10, 91058 Erlangen, Germany
| | - Stefan Kniesburges
- Division of Phoniatrics and Pediatric Audiology, Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Erlangen, Medical School, Friedrich-Alexander-Universität Erlangen-Nürnberg, Waldstrasse 1, 91054 Erlangen, Germany
| |
Collapse
|
4
|
Semmler M, Lasar S, Kremer F, Reinwald L, Wittig F, Peters G, Schraut T, Wendler O, Seyferth S, Schützenberger A, Dürr S. Extent and Effect of Covering Laryngeal Structures with Synthetic Laryngeal Mucus via Two Different Administration Techniques. J Voice 2023:S0892-1997(23)00228-X. [PMID: 37648625 DOI: 10.1016/j.jvoice.2023.07.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2023] [Revised: 07/20/2023] [Accepted: 07/21/2023] [Indexed: 09/01/2023]
Abstract
OBJECTIVE The first goal of this study was to investigate the coverage of laryngeal structures using two potential administration techniques for synthetic mucus: inhalation and lozenge ingestion. As a second research question, the study investigated the potential effects of these techniques on standardized voice assessment parameters. METHODS Fluorescein was added to throat lozenges and to an inhalation solution to visualize the coverage of laryngeal structures through blue light imaging. The study included 70 vocally healthy subjects. Fifty subjects underwent administration via lozenge ingestion and 20 subjects performed the inhalation process. For the first research question, the recordings from the blue light imaging system were categorized to compare the extent of coverage on individual laryngeal structures objectively. Secondly, a standardized voice evaluation protocol was performed before and after each administration to determine any measurable effects of typical voice parameters. RESULTS The administration via inhalation demonstrated complete coverage of all laryngeal structures, including the vocal folds, ventricular folds, and arytenoid cartilages, as visualized by the fluorescent dye. In contrast, the application of the lozenge predominantly covered the pharynx and laryngeal surface toward the aryepiglottic fold, but not the inferior structures. All in all, the comparison before and after administration showed no clear effect, although a minor deterioration of the acoustic signal was noted in the shimmer and cepstral peak prominence after the inhalation. CONCLUSIONS Our findings indicate that the inhalation process is a more effective technique for covering deeper laryngeal structures such as the vocal folds and ventricular folds with synthetic mucus. This knowledge enables further in vivo studies on the role of laryngeal mucus in phonation in general, and how it can be substituted or supplemented for patients with reduced glandular activity as well as for heavy voice users.
Collapse
Affiliation(s)
- Marion Semmler
- University Hospital Erlangen, Medical School, Division of Phoniatrics and Pediatric Audiology at the Department of Otorhinolaryngology Head & Neck Surgery, Friedrich-Alexander-University Erlangen-Nürnberg, Waldstrasse 1, 91054 Erlangen, Germany.
| | - Sarina Lasar
- University Hospital Erlangen, Medical School, Division of Phoniatrics and Pediatric Audiology at the Department of Otorhinolaryngology Head & Neck Surgery, Friedrich-Alexander-University Erlangen-Nürnberg, Waldstrasse 1, 91054 Erlangen, Germany.
| | - Franziska Kremer
- University Hospital Erlangen, Medical School, Division of Phoniatrics and Pediatric Audiology at the Department of Otorhinolaryngology Head & Neck Surgery, Friedrich-Alexander-University Erlangen-Nürnberg, Waldstrasse 1, 91054 Erlangen, Germany.
| | - Laura Reinwald
- University Hospital Erlangen, Medical School, Division of Phoniatrics and Pediatric Audiology at the Department of Otorhinolaryngology Head & Neck Surgery, Friedrich-Alexander-University Erlangen-Nürnberg, Waldstrasse 1, 91054 Erlangen, Germany.
| | - Fiori Wittig
- University Hospital Erlangen, Medical School, Division of Phoniatrics and Pediatric Audiology at the Department of Otorhinolaryngology Head & Neck Surgery, Friedrich-Alexander-University Erlangen-Nürnberg, Waldstrasse 1, 91054 Erlangen, Germany.
| | - Gregor Peters
- University Hospital Erlangen, Medical School, Division of Phoniatrics and Pediatric Audiology at the Department of Otorhinolaryngology Head & Neck Surgery, Friedrich-Alexander-University Erlangen-Nürnberg, Waldstrasse 1, 91054 Erlangen, Germany.
| | - Tobias Schraut
- University Hospital Erlangen, Medical School, Division of Phoniatrics and Pediatric Audiology at the Department of Otorhinolaryngology Head & Neck Surgery, Friedrich-Alexander-University Erlangen-Nürnberg, Waldstrasse 1, 91054 Erlangen, Germany.
| | - Olaf Wendler
- University Hospital Erlangen, Medical School, Division of Phoniatrics and Pediatric Audiology at the Department of Otorhinolaryngology Head & Neck Surgery, Friedrich-Alexander-University Erlangen-Nürnberg, Waldstrasse 1, 91054 Erlangen, Germany.
| | - Stefan Seyferth
- Department of Chemistry and Pharmacy, Chair of Pharmaceutics, Friedrich-Alexander-University Erlangen-Nürnberg, Cauerstr. 4, 91058 Erlangen, Germany.
| | - Anne Schützenberger
- University Hospital Erlangen, Medical School, Division of Phoniatrics and Pediatric Audiology at the Department of Otorhinolaryngology Head & Neck Surgery, Friedrich-Alexander-University Erlangen-Nürnberg, Waldstrasse 1, 91054 Erlangen, Germany.
| | - Stephan Dürr
- University Hospital Regensburg, Department of Otorhinolaryngology, Division of Phoniatrics and Pediatric Audiology, Franz-Josef-Strauß-Allee 11, 93053 Regensburg, Germany.
| |
Collapse
|