1
|
Di Bacco VE, Gage WH. Validation of Linear and Nonlinear Gait Variability Measures Derived From a Smartphone System Compared to a Gold-Standard Footswitch System During Overground Walking. J Appl Biomech 2024; 40:437-443. [PMID: 39222917 DOI: 10.1123/jab.2022-0293] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2022] [Revised: 02/29/2024] [Accepted: 07/03/2024] [Indexed: 09/04/2024]
Abstract
Smartphones, with embedded accelerometers, may be a viable method to monitor gait variability in the free-living environment. However, measurements estimated using smartphones must first be compared to known quantities to ensure validity. This study assessed the validity and reliability of smartphone-derived gait measures compared to a gold-standard footswitch system during overground walking. Seventeen adults completed three 8-minute overground walking trials during 3 separate visits. The stride time series was calculated as the time difference between consecutive right heel contact events within the footswitch and smartphone-accelerometry signals. Linear (average stride time, stride time standard deviation, and stride time coefficient of variation) and nonlinear (fractal scaling index, approximate entropy, and sample entropy) measures were calculated for each stride time series. Bland-Altman plots with 95% limits of agreement assessed agreement between systems. Intraclass correlation coefficients assessed reliability across visits. Bland-Altman plots revealed acceptable limits of agreement for all measures. Intraclass correlation coefficients revealed good-to-excellent reliability for both systems, except for fractal scaling index, which was moderate. The smartphone system is a valid method and performs similarly to gold-standard research equipment. These findings suggest the development and implementation of an inexpensive, easy-to-use, and ubiquitous telehealth instrument that may replace traditional laboratory equipment for use in the free-living environment.
Collapse
Affiliation(s)
- Vincenzo E Di Bacco
- School of Kinesiology and Health Science, York University, Toronto, ON, Canada
| | - William H Gage
- School of Kinesiology and Health Science, York University, Toronto, ON, Canada
| |
Collapse
|
2
|
Di Bacco VE, Gage WH. Evaluation of a smartphone accelerometer system for measuring nonlinear dynamics during treadmill walking: Concurrent validity and test-retest reliability. J Biomech 2023; 151:111527. [PMID: 36948001 DOI: 10.1016/j.jbiomech.2023.111527] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2022] [Revised: 02/26/2023] [Accepted: 03/02/2023] [Indexed: 03/09/2023]
Abstract
The accelerometers embedded within smartphones may be a promising tool to capture gait patterns outside the laboratory and for extended periods of time. The current study evaluated the agreement and reliability of gait measures derived from a smartphone accelerometer system, compared to reference motion capture and footswitch systems during treadmill walking. Seventeen healthy young adults visited the laboratory on three separate days and completed three 8-minute treadmill walking trials, during each visit, at their preferred walking speed. The inter-stride interval series was calculated as the time difference between consecutive right heel contacts, located within the signals of the smartphone accelerometer, motion capture, and footswitch systems. The inter-stride interval series was used to estimate common linear gait measures and nonlinear measures, including fractal scaling index, approximate entropy, and sample entropy. Bland Altman plots with 95% limits of agreement and intraclass correlation coefficients assessed agreement and reliability, respectively. The smartphone system was found to be within the acceptable limits of agreement when compared to either reference system. The intraclass correlation coefficients values revealed moderate-to-excellent reliability for the smartphone system, with greater reliability found for linear compared to nonlinear measures and were similar to both reference systems, except for the fractal scaling index. These findings suggest the smartphone accelerometer system is a valid and reliable method for estimating linear and nonlinear gait measures during treadmill walking.
Collapse
Affiliation(s)
- Vincenzo E Di Bacco
- School of Kinesiology and Health Science, York University, Toronto, ON, Canada.
| | - William H Gage
- School of Kinesiology and Health Science, York University, Toronto, ON, Canada
| |
Collapse
|
3
|
Barden JM, Hoffert L, Ruf S, McCarville D, Kopriva D. The effect of peripheral arterial disease and intermittent claudication on gait regularity and symmetry. J Biomech 2022; 141:111205. [PMID: 35759975 DOI: 10.1016/j.jbiomech.2022.111205] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2021] [Revised: 06/10/2022] [Accepted: 06/16/2022] [Indexed: 11/26/2022]
Abstract
Peripheral arterial disease (PAD) affects 20-30% of older adults and is associated with intermittent claudication (IC), which is walking-induced pain. This study compared the regularity and symmetry of gait between healthy older adults and adults with PAD, and between IC and non-IC conditions in the PAD group. Eighteen control (70.7 ± 6.3 years) and 11 PAD participants (67.0 ± 10.1 years) walked overground at a continuous, self-selected speed. A waist-mounted accelerometer determined step time, stride time, gait speed and mediolateral (ML), vertical (V) and anteroposterior (AP) gait regularity (step/stride) and symmetry. Correlations between ankle-brachial index (ABI) scores and PAD gait regularity/symmetry were also investigated. PAD step and stride times were greater (p < 0.01), while gait speed, ML and AP step regularity and ML and V stride regularity were significantly less than the controls (p < 0.05). There were no significant differences in gait symmetry. Within the PAD group, post-IC step/stride time and speed increased and decreased, respectively, (p < 0.05), while post-IC step and stride regularity were significantly less in all three directions (p < 0.01). Similarly, ML and V post-IC gait asymmetry increased significantly (p < 0.05). ABI was significantly correlated with pre-and post-IC vertical stride regularity (p < 0.01), and with pre- and post-IC ML gait symmetry (p < 0.05). The results demonstrate that gait regularity decreases as a result of PAD and IC. The association between gait regularity/symmetry and ABI should be investigated further, as it may have clinical application to the assessment of PAD severity.
Collapse
Affiliation(s)
- John M Barden
- Faculty of Kinesiology and Health Studies, University of Regina, Regina, SK, Canada.
| | - Lucas Hoffert
- College of Medicine, University of Saskatchewan, Saskatoon, SK, Canada.
| | - Sarah Ruf
- Faculty of Kinesiology and Health Studies, University of Regina, Regina, SK, Canada
| | - Don McCarville
- Division of Vascular Surgery, Saskatchewan Health Authority, Regina, SK, Canada.
| | - David Kopriva
- Division of Vascular Surgery, Department of Surgery, College of Medicine, University of Saskatchewan, Saskatoon, SK, Canada.
| |
Collapse
|
4
|
Gait Recognition for Lower Limb Exoskeletons Based on Interactive Information Fusion. Appl Bionics Biomech 2022; 2022:9933018. [PMID: 35378794 PMCID: PMC8976668 DOI: 10.1155/2022/9933018] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2021] [Revised: 11/10/2021] [Accepted: 03/05/2022] [Indexed: 11/18/2022] Open
Abstract
In recent decades, although the research on gait recognition of lower limb exoskeleton robot has been widely developed, there are still limitations in rehabilitation training and clinical practice. The emergence of interactive information fusion technology provides a new research idea for the solution of this problem, and it is also the development trend in the future. In order to better explore the issue, this paper summarizes gait recognition based on interactive information fusion of lower limb exoskeleton robots. This review introduces the current research status, methods, and directions for information acquisition, interaction, fusion, and gait recognition of exoskeleton robots. The content involves the research progress of information acquisition methods, sensor placements, target groups, lower limb sports biomechanics, interactive information fusion, and gait recognition model. Finally, the current challenges, possible solutions, and promising prospects are analysed and discussed, which provides a useful reference resource for the study of interactive information fusion and gait recognition of rehabilitation exoskeleton robots.
Collapse
|
5
|
Oliveira LM, Roizenblatt S, Silva FD, Roizenblatt A, Fernandes ARC, Szejnfeld VL. Relationship of the sacral slope with early gait derangements in robust older women. Adv Rheumatol 2021; 61:35. [PMID: 34118988 DOI: 10.1186/s42358-021-00191-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2020] [Accepted: 05/25/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Trunk pelvic dissociation is fundamental to the compensatory mechanism for muscle weakness during body bending. We carried out an early investigation of gait changes in a sample of community-dwelling women ≥60 years without gait complaints. The primary objective was to correlate spine and pelvic angles with performance tests and accelerometry parameters. The secondary objective was to correlate performance tests with accelerometry. METHODS In this cross-sectional study, 54 community-dwelling women ≥60 years were subjected to Falls Efficacy Scale-International (FES-I), performance tests (Berg Balance Scale, Timed Up and Go, and Gait analysis), and radiographic analysis of sagittal alignment (Thoracic and Lumbar Cobb, Pelvic Incidence, Sacral Slope, and Pelvic Tilt angles). Gait speed was assessed in a 10-m comfortable walk, and accelerometry parameters were obtained in a 30-m walk distance. RESULTS The sample, aged 72 ± 6 years, exhibited moderate correlation between Sacral Slope and Step Length (+ 0.615). Sacral Slope weakly correlated with FES-I (- 0.339), Berg Balance Scale (+ 0.367), and with further accelerometry data in the AP plane: RMS, (+ 0.439) and Stride Regularity (+ 0.475), p < 0.05, all. Lumbar Cobb weakly correlated with the following accelerometry data in the AP plane: Step Length (+ 0.405), RMS, (+ 0.392), and Stride Regularity (+ 0.345), p < 0.05, all. Additionally, Stride Regularity in AP moderately correlated with FES-I (0,561, p < 0.05), among other weak correlations between performance tests and accelerometry data in AP. CONCLUSIONS Early alterations in Sacral Slope and gait abnormalities in the AP plane may provide understanding of the early gait changes in robust older women.
Collapse
Affiliation(s)
| | - Suely Roizenblatt
- Department of Internal Medicine, Universidade Federal de Sao Paulo (UNIFESP), Rua Angelina Maffei Vita 670. CEP:01455070, Sao Paulo, SP, Brazil.
| | - Flavio Duarte Silva
- Department of Diagnostic Imaging, Universidade Federal de Sao Paulo (UNIFESP), São Paulo, Brazil
| | - Arnaldo Roizenblatt
- Medical Student Universidade Federal de Sao Paulo (UNIFESP), São Paulo, Brazil
| | | | - Vera Lucia Szejnfeld
- Rheumatology Division, Universidade Federal de Sao Paulo (UNIFESP), São Paulo, Brazil
| |
Collapse
|
6
|
Li X, Zhou Z, Wu J, Xiong Y. Human Posture Detection Method Based on Wearable Devices. JOURNAL OF HEALTHCARE ENGINEERING 2021; 2021:8879061. [PMID: 33833862 PMCID: PMC8016574 DOI: 10.1155/2021/8879061] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/07/2020] [Revised: 11/20/2020] [Accepted: 03/14/2021] [Indexed: 12/04/2022]
Abstract
The dynamic detection of human motion is important, which is widely applied in the fields of motion state capture and rehabilitation engineering. In this study, based on multimodal information of surface electromyography (sEMG) signals of upper limb and triaxial acceleration and plantar pressure signals of lower limb, the effective virtual driving control and gait recognition methods were proposed. The effective way of wearable human posture detection was also constructed. Firstly, the moving average window and threshold comparison were used to segment the sEMG signals of the upper limb. The standard deviation and singular values of wavelet coefficients were extracted as the features. After the training and classification by optimized support vector machine (SVM) algorithm, the real-time detection and analysis of three virtual driving actions were performed. The average identification accuracy was 90.90%. Secondly, the mean, standard deviation, variance, and wavelet energy spectrum of triaxial acceleration were extracted, and these parameters were combined with plantar pressure as the gait features. The optimized SVM was selected for the gait identification, and the average accuracy was 90.48%. The experimental results showed that, through different combinations of wearable sensors on the upper and lower limbs, the motion posture information could be dynamically detected, which could be used in the design of virtual rehabilitation system and walking auxiliary system.
Collapse
Affiliation(s)
- Xiaoou Li
- College of Medical Instruments, Shanghai University of Medicine & Health Sciences, Shanghai 201318, China
| | - Zhiyong Zhou
- School of Design and Art, Shanghai Dianji University, Shanghai 200240, China
| | - Jiajia Wu
- College of Medical Instruments, Shanghai University of Medicine & Health Sciences, Shanghai 201318, China
| | - Yichao Xiong
- College of Medical Instruments, Shanghai University of Medicine & Health Sciences, Shanghai 201318, China
| |
Collapse
|
7
|
Test-Retest Reliability and the Effects of Walking Speed on Stride Time Variability During Continuous, Overground Walking in Healthy Young Adults. J Appl Biomech 2020; 37:102-108. [PMID: 33361489 DOI: 10.1123/jab.2020-0138] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2020] [Revised: 08/24/2020] [Accepted: 09/29/2020] [Indexed: 11/18/2022]
Abstract
Studies have investigated the reliability and effect of walking speed on stride time variability during walking trials performed on a treadmill. The objective of this study was to investigate the reliability of stride time variability and the effect of walking speed on stride time variability, during continuous, overground walking in healthy young adults. Participants completed: (1) 2 walking trials at their preferred walking speed on 1 day and another trial 2 to 4 days later and (2) 1 trial at their preferred walking speed, 1 trial approximately 20% to 25% faster than their preferred walking speed, and 1 trial approximately 20% to 25% slower than their preferred walking speed on a separate day. Data from a waist-mounted accelerometer were used to determine the consecutive stride times for each trial. The reliability of stride time variability outcomes was generally poor (intraclass correlations: .167-.487). Although some significant differences in stride time variability were found between the preferred walking speed, fast, and slow trials, individual between-trial differences were generally below the estimated minimum difference considered to be a real difference. The development of a protocol to improve the reliability of stride time variability outcomes during continuous, overground walking would be beneficial to improve their application in research and clinical settings.
Collapse
|
8
|
Vangeneugden J, Verlaan L, Oomen P, Liu WY, Peters M, Natour N, Emans P, Meijer K. Signatures of knee osteoarthritis in women in the temporal and fractal dynamics of human gait. Clin Biomech (Bristol, Avon) 2020; 76:105016. [PMID: 32438265 DOI: 10.1016/j.clinbiomech.2020.105016] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/16/2019] [Revised: 02/06/2020] [Accepted: 04/21/2020] [Indexed: 02/07/2023]
Abstract
BACKGROUND Osteoarthritis of the knee is characterized by progressive cartilage deterioration causing pain and function loss. Symptoms develop late with limited disease-modifying opportunities. Osteoarthritis is a major cause of immobility, with a higher prevalence above 60 years. This age-related increase in prevalence is further amplified by the female gender. Imaging and biochemical analyses for detection of osteoarthritis of the knee are expensive and labor-intensive. Continuous movement tracking could aid in detecting onset and/or worsening of symptoms. METHODS We used portable technology to investigate kinematic differences in female patients with knee osteoarthritis, weight-matched healthy female volunteers and obese female patients with osteoarthritis of the knee. Knee osteoarthritis was established radiographically and corroborated using magnetic resonance imaging. FINDINGS The total amount, type and level of activity did not differ significantly between groups. The temporal activity pattern during the day was however significantly different with a bimodal signature in healthy volunteers only. Sequence analyses revealed more time to recuperate after dynamic activity in both patient groups. Analysis of walking bouts revealed significant differences in stride interval dynamics, indicative of gait naturalness, only in healthy volunteers. Temporal activity, sequence and walking patterns were independent of body weight. INTERPRETATION We thus provide for the first-time evidence of temporal specific kinematic signatures in amount and quality of movement also in stride interval dynamics between people with and without osteoarthritis of the knee independent of body weight. These findings could allow early and non-intrusive diagnosis of osteoarthritis enabling concordant treatment.
Collapse
Affiliation(s)
- Joris Vangeneugden
- Department of Orthopedic Surgery, CAPHRI School for Public Health and Primary Care, Maastricht University Medical Center, P.O. Box 5800, 6202, AZ, Maastricht, the Netherlands; Department of Psychiatry & Neuropsychology, Division of Translational Neuroscience, Maastricht University, the Netherlands
| | - Loek Verlaan
- Department of Orthopedic Surgery, CAPHRI School for Public Health and Primary Care, Maastricht University Medical Center, P.O. Box 5800, 6202, AZ, Maastricht, the Netherlands.
| | - Pieter Oomen
- Department of Human Movement Sciences, NUTRIM School for Nutrition, Toxicology and metabolism, Maastricht University Medical Center, P.O. Box 616, 6200, MD, Maastricht, the Netherlands
| | - Wai-Yan Liu
- Department of Human Movement Sciences, NUTRIM School for Nutrition, Toxicology and metabolism, Maastricht University Medical Center, P.O. Box 616, 6200, MD, Maastricht, the Netherlands
| | - Marloes Peters
- Department of Orthopedic Surgery, CAPHRI School for Public Health and Primary Care, Maastricht University Medical Center, P.O. Box 5800, 6202, AZ, Maastricht, the Netherlands
| | - Nicole Natour
- Department of Nuclear Medicine and Radiology, Maastricht University Medical Center, the Netherlands
| | - Pieter Emans
- Department of Orthopedic Surgery, CAPHRI School for Public Health and Primary Care, Maastricht University Medical Center, P.O. Box 5800, 6202, AZ, Maastricht, the Netherlands
| | - Kenneth Meijer
- Department of Human Movement Sciences, NUTRIM School for Nutrition, Toxicology and metabolism, Maastricht University Medical Center, P.O. Box 616, 6200, MD, Maastricht, the Netherlands
| |
Collapse
|
9
|
Benson LC, Clermont CA, Bošnjak E, Ferber R. The use of wearable devices for walking and running gait analysis outside of the lab: A systematic review. Gait Posture 2018; 63:124-138. [PMID: 29730488 DOI: 10.1016/j.gaitpost.2018.04.047] [Citation(s) in RCA: 118] [Impact Index Per Article: 19.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/13/2017] [Revised: 03/20/2018] [Accepted: 04/28/2018] [Indexed: 02/02/2023]
Abstract
BACKGROUND Quantitative gait analysis is essential for evaluating walking and running patterns for markers of pathology, injury, or other gait characteristics. It is expected that the portability, affordability, and applicability of wearable devices to many different populations will have contributed advancements in understanding the real-world gait patterns of walkers and runners. Therefore, the purpose of this systematic review was to identify how wearable devices are being used for gait analysis in out-of-lab settings. METHODS A systematic search was conducted in the following scientific databases: PubMed, Medline, CINAHL, EMBASE, and SportDiscus. Each of the included articles was assessed using a custom quality assessment. Information was extracted from each included article regarding the participants, protocol, sensor(s), and analysis. RESULTS A total of 61 articles were reviewed: 47 involved gait analysis during walking, 13 involved gait analysis during running, and one involved both walking and running. Most studies performed adequately on measures of reporting, and external and internal validity, but did not provide a sufficient description of power. Small, unobtrusive wearable devices have been used in retrospective studies, producing unique measures of gait quality. Walking, but not running, studies have begun to use wearable devices for gait analysis among large numbers of participants in their natural environment. CONCLUSIONS Despite the advantages provided by the portability and accessibility of wearable devices, more studies monitoring gait over long periods of time, among large numbers of participants, and in natural walking and running environments are needed to analyze real-world gait patterns, and would facilitate prospective, subject-specific, and subgroup investigations. The development of wearables-specific metrics for gait analysis provide insights regarding the quality of gait that cannot be determined using traditional components of in-lab gait analyses. However, guidelines for the usability of wearable devices and the validity of wearables-based measurements of gait quality need to be established.
Collapse
Affiliation(s)
- Lauren C Benson
- Faculty of Kinesiology, University of Calgary, 2500 University Dr. NW, Calgary, AB, T2N 1N4, Canada.
| | - Christian A Clermont
- Faculty of Kinesiology, University of Calgary, 2500 University Dr. NW, Calgary, AB, T2N 1N4, Canada.
| | - Eva Bošnjak
- Faculty of Kinesiology, University of Calgary, 2500 University Dr. NW, Calgary, AB, T2N 1N4, Canada.
| | - Reed Ferber
- Faculty of Kinesiology, University of Calgary, 2500 University Dr. NW, Calgary, AB, T2N 1N4, Canada; Faculty of Nursing, University of Calgary, 2500 University Dr. NW, Calgary, AB, T2N 1N4, Canada; Running Injury Clinic, 2500 University Dr. NW, Calgary, AB, T2N 1N4, Canada.
| |
Collapse
|
10
|
Brahms CM, Zhao Y, Gerhard D, Barden JM. Stride length determination during overground running using a single foot-mounted inertial measurement unit. J Biomech 2018; 71:302-305. [DOI: 10.1016/j.jbiomech.2018.02.003] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2017] [Revised: 01/31/2018] [Accepted: 02/01/2018] [Indexed: 01/20/2023]
|
11
|
Barden JM, Clermont CA, Kobsar D, Beauchet O. Accelerometer-Based Step Regularity Is Lower in Older Adults with Bilateral Knee Osteoarthritis. Front Hum Neurosci 2016; 10:625. [PMID: 28008312 PMCID: PMC5143349 DOI: 10.3389/fnhum.2016.00625] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2016] [Accepted: 11/23/2016] [Indexed: 01/09/2023] Open
Abstract
Purpose: To compare the regularity and symmetry of gait between a cohort of older adults with bilateral knee osteoarthritis (OA) and an age and sex-matched control group of older adults with healthy knees. Methods: Fifteen (8 females) older adults with knee OA (64.7 ± 6.7 years) and fifteen (8 females) pain-free controls (66.1 ± 10.0 years) completed a 9-min. walk at a self-selected, comfortable speed while wearing a single waist-mounted tri-axial accelerometer. The following gait parameters were compared between the two groups according to sex: mean step time, mean stride time, stride and step regularity (defined as the consistency of the stride-to-stride or step-to-step pattern) and the symmetry of gait (defined as the difference between step and stride regularity) as determined by an unbiased autocorrelation procedure that analyzed the pattern of acceleration in the vertical, mediolateral and anteroposterior directions. Results: Older adults with knee OA displayed significantly less step regularity in the vertical (p < 0.05) and anteroposterior (p < 0.05) directions than controls. Females with knee OA were also found to have significantly less mediolateral step regularity than female controls (p < 0.05), whereas no difference was found between males. Conclusion: The results showed that the regularity of the step pattern in individuals with bilateral knee OA was less consistent compared to similarly-aged older adults with healthy knees. The findings suggest that future studies should investigate the relationship between step regularity, sex and movement direction as well as the application of these methods to the clinical assessment of knee OA.
Collapse
Affiliation(s)
- John M Barden
- Faculty of Kinesiology and Health Studies, Neuromechanical Research Centre, University of Regina Regina, SK, Canada
| | | | - Dylan Kobsar
- Faculty of Kinesiology, University of Calgary Calgary, AB, Canada
| | - Olivier Beauchet
- Division of Geriatric Medicine, Department of Medicine, McGill University Montreal, QC, Canada
| |
Collapse
|
12
|
Kobsar D, Osis ST, Phinyomark A, Boyd JE, Ferber R. Reliability of gait analysis using wearable sensors in patients with knee osteoarthritis. J Biomech 2016; 49:3977-3982. [PMID: 27889189 DOI: 10.1016/j.jbiomech.2016.11.047] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2016] [Revised: 11/10/2016] [Accepted: 11/11/2016] [Indexed: 11/15/2022]
Abstract
The aim of this study was to determine the test-retest reliability of linear acceleration waveforms collected at the low back, thigh, shank, and foot during walking, in a cohort of knee osteoarthritis patients, by applying two separate sensor attitude correction methods (static attitude correction and dynamic attitude correction). Linear acceleration data were collected on the subjects׳ most affected limb during treadmill walking on two separate days. Results reveal all attitude corrected acceleration waveforms displayed high repeatability, with coefficient of multiple determination values ranging from 0.82 to 0.99. Overall, mediolateral accelerations and the thigh sensor demonstrated the lowest reliabilities, but interaction effects revealed only mediolateral accelerations at the thigh and foot sensors were different than other axes and sensor locations. Both attitude correction methods led to improved reliability of linear acceleration waveforms. These findings suggest that while all sensor locations and axes display acceptable reliability in a clinical knee osteoarthritis population, the back and shank locations, and the vertical and anteroposterior acceleration directions, are most reliable.
Collapse
Affiliation(s)
- Dylan Kobsar
- Faculty of Kinesiology, University of Calgary, Calgary, Alberta, Canada.
| | - Sean T Osis
- Faculty of Kinesiology, University of Calgary, Calgary, Alberta, Canada
| | | | - Jeffrey E Boyd
- Department of Computer Science, University of Calgary, Calgary, Alberta, Canada
| | - Reed Ferber
- Faculty of Kinesiology, University of Calgary, Calgary, Alberta, Canada; Faculty of Nursing, University of Calgary, Calgary, Alberta, Canada
| |
Collapse
|
13
|
Clermont CA, Barden JM. Accelerometer-based determination of gait variability in older adults with knee osteoarthritis. Gait Posture 2016; 50:126-130. [PMID: 27607303 DOI: 10.1016/j.gaitpost.2016.08.024] [Citation(s) in RCA: 35] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/27/2015] [Revised: 07/25/2016] [Accepted: 08/23/2016] [Indexed: 02/02/2023]
Abstract
Knee osteoarthritis (KOA) can affect the spatiotemporal (ST) aspects of gait as well as the variability of select ST parameters based on standard linear measures of variability (e.g., standard deviation (SD) and coefficient of variation). Non-linear measures (e.g., fractal scaling index (FSI) and sample entropy) can be more sensitive to changes in gait variability, and have been used to quantify differences in the stride patterns of patients with Parkinson's disease and the motion of ACL-deficient knees. However, the effect of KOA on the dynamic complexity of the stride pattern has not been investigated. Therefore, the purpose of this study was to investigate the effect of KOA on gait variability (linear and non-linear measures) in a group of older adults, and to compare these results to a healthy control group. Participants walked for 10min with a tri-axial accelerometer placed at the lower back. Mean and SDs of stride time and step time as well as the FSI for the entire series of stride times were calculated for each participant. Participants with KOA had significantly greater mean stride time (p=0.031) and step time (p=0.024) than control group participants. While stride and step time variability (SD) were greater in the KOA group, the differences were not significant, nor was the difference in the FSI. Low statistical power (β=0.40 and 0.30 for stride and step time SD, respectively) combined with the confounding effects of walking speed and heterogeneous KOA severity likely prevented significant differences from being found.
Collapse
Affiliation(s)
- Christian A Clermont
- University of Regina, Faculty of Kinesiology & Health Studies, University of Regina 3737 Wascana Parkway Regina, Saskatchewan, S4S 0A2, Canada.
| | - John M Barden
- University of Regina, Faculty of Kinesiology & Health Studies, University of Regina 3737 Wascana Parkway Regina, Saskatchewan, S4S 0A2, Canada.
| |
Collapse
|
14
|
Godfrey A, Lara J, Munro CA, Wiuff C, Chowdhury SA, Del Din S, Hickey A, Mathers JC, Rochester L. Instrumented assessment of test battery for physical capability using an accelerometer: a feasibility study. Physiol Meas 2015; 36:N71-83. [PMID: 25903399 DOI: 10.1088/0967-3334/36/5/n71] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Recent work has identified subdomains (tests) of physical capability that are recommended for assessment of the healthy ageing phenotype (HAP). These include: postural control, locomotion, endurance, repeated sit-to-stand-to-sit and TUG. Current assessment methods lack sensitivity and are error prone due to their lack of consistency and heterogeneity of reported outcomes; instrumentation with body worn monitors provides a method to address these potential weaknesses. This work proposes the use of a single tri-axial accelerometer-based device with appropriate algorithms (referred to here as a body worn monitor, BWM) for the purposes of instrumented testing during physicality capability assessment. In this pilot study we present 14 BWM-based outcomes across the subdomains which include magnitude, frequency and spatio-temporal characteristics. Where possible, we compared BWM outcomes with manually recorded values and found no significant differences between locomotion and TUG tasks (p ≥ 0.319). Significant differences were found for the total distance walked during endurance (p = 0.037) and times for repeated sit-to-stand-to-sit transitions (p < 0.000). We identified reasons for differences and make recommendations for future testing. We were also able to quantify additional characteristics of postural control and gait which could be sensitive outcomes for future HAP assessment. Our findings demonstrate the feasibility of this method to enhance measurement of physical capacity. The methodology can also be applied to a wide variety of accelerometer-based monitors and is applicable to a range of intervention-based studies or pathological assessment.
Collapse
Affiliation(s)
- A Godfrey
- Institute of Neuroscience, Newcastle University, Campus for Ageing and Vitality, Newcastle upon Tyne, UK. Clinical Ageing Research Unit, Newcastle University, Campus for Ageing and Vitality, Newcastle upon Tyne, UK
| | | | | | | | | | | | | | | | | |
Collapse
|