1
|
Sherman SE, Zammit AS, Heo WS, Rosen MS, Cima MJ. Single-sided magnetic resonance-based sensor for point-of-care evaluation of muscle. Nat Commun 2024; 15:440. [PMID: 38199994 PMCID: PMC10782019 DOI: 10.1038/s41467-023-44561-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2023] [Accepted: 12/19/2023] [Indexed: 01/12/2024] Open
Abstract
Magnetic resonance imaging is a widespread clinical tool for the detection of soft tissue morphology and pathology. However, the clinical deployment of magnetic resonance imaging scanners is ultimately limited by size, cost, and space constraints. Here, we discuss the design and performance of a low-field single-sided magnetic resonance sensor intended for point-of-care evaluation of skeletal muscle in vivo. The 11 kg sensor has a penetration depth of >8 mm, which allows for an accurate analysis of muscle tissue and can avoid signal from more proximal layers, including subcutaneous adipose tissue. Low operational power and shielding requirements are achieved through the design of a permanent magnet array and surface transceiver coil. The sensor can acquire high signal-to-noise measurements in minutes, making it practical as a point-of-care tool for many quantitative diagnostic measurements, including T2 relaxometry. In this work, we present the in vitro and human in vivo performance of the device for muscle tissue evaluation.
Collapse
Affiliation(s)
- Sydney E Sherman
- Harvard-MIT Program in Health Science and Technology, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
- Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| | - Alexa S Zammit
- Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
- Department of Materials Science and Engineering, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| | - Won-Seok Heo
- Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| | - Matthew S Rosen
- Department of Radiology, Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Boston, MA, 02129, USA
- Harvard Medical School, Boston, MA, 02115, USA
- Department of Physics, Harvard University, Cambridge, MA, 02138, USA
| | - Michael J Cima
- Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA.
- Department of Materials Science and Engineering, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA.
| |
Collapse
|
2
|
Cima M, Sherman S, Zammit A, Heo WS, Rosen M. Single-sided magnetic resonance-based sensor for point-of-care evaluation of muscle. RESEARCH SQUARE 2023:rs.3.rs-3335248. [PMID: 37790511 PMCID: PMC10543496 DOI: 10.21203/rs.3.rs-3335248/v1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/05/2023]
Abstract
Magnetic resonance (MR) imaging is a powerful clinical tool for the detection of soft tissue morphology and pathology, which often provides actionable diagnostic information to clinicians. Its clinical use is largely limited due to size, cost, time, and space constraints. Here, we discuss the design and performance of a low-field single-sided MR sensor intended for point-of-care (POC) evaluation of skeletal muscle in vivo. The 11kg sensor has a penetration depth of > 8 mm, which allows for an accurate analysis of muscle tissue and can avoid signal from more proximal layers, including subcutaneous adipose tissue. Low operational power and minimal shielding requirements are achieved through the design of a permanent magnet array and surface transceiver coil. We present the in vitro and human in vivo performance of the device for muscle tissue evaluation. The sensor can acquire high signal-to-noise (SNR > 150) measurements in minutes, making it practical as a POC tool for many quantitative diagnostic measurements, including T2 relaxometry.
Collapse
Affiliation(s)
| | | | | | | | - Matthew Rosen
- Massachusetts General Hospital and Harvard Medical School
| |
Collapse
|
3
|
Karlsson M, Indurain A, Romu T, Tunon P, Segelmark M, Uhlin F, Fernström A, Leinhard OD. Assessing Tissue Hydration Dynamics Based on Water/Fat Separated MRI. J Magn Reson Imaging 2023. [PMID: 36591977 DOI: 10.1002/jmri.28581] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2022] [Revised: 12/13/2022] [Accepted: 12/13/2022] [Indexed: 01/03/2023] Open
Abstract
BACKGROUND Optimal fluid status is an important issue in hemodialysis. Clinical evaluation of volume status and different diagnostic tools are used to determine hydration status in these patients. However, there is still no accurate method for this assessment. PURPOSE To propose and evaluate relative lean water signal (LWSrel ) as a water-fat MRI-based tissue hydration measurement. STUDY TYPE Prospective. POPULATION A total of 16 healthy subjects (56 ± 6 years, 0 male) and 11 dialysis patients (60.3 ± 12.3 years, 9 male; dialysis time per week 15 ± 3.5 hours, dialysis duration 31.4 ± 27.9 months). FIELD STRENGTH/SEQUENCE A 3 T; 3D spoiled gradient echo. ASSESSMENT LWSrel , a measurement of the water concentration of tissue, was estimated from fat-referenced MR images. Segmentations of total adipose tissue as well as thigh and calf muscles were used to measure LWSrel and tissue volumes. LWSrel was compared between healthy subjects and dialysis patients, the latter before and after dialysis. Bioimpedance-based body composition monitor over hydration (BCM OH) was also measured. STATISTICAL TESTS T-tests were used to compare differences between the healthy subjects and dialysis patients, as well as changes between before and after dialysis. Pearson correlation was calculated between MRI and non-MRI biomarkers. A P value <0.05 was considered statistically significant. RESULTS The LWSrel in adipose tissue was significantly higher in the dialysis cohort compared with the healthy cohort (246.8% ± 60.0% vs. 100.0% ± 10.8%) and decreased significantly after dialysis (246.8 ± 60.0% vs. 233.8 ± 63.4%). Thigh and calf muscle volumes also significantly decreased by 3.78% ± 1.73% and 2.02% ± 2.50% after dialysis. There was a significant correlation between changes in adipose tissue LWSrel and ultrafiltration volume (r = 87), as well as with BCM OH (r = 0.66). DATA CONCLUSION MRI-based LWSrel and tissue volume measurements are sensitive to tissue hydration changes occurring during dialysis. EVIDENCE LEVEL 2. TECHNICAL EFFICACY Stage 3.
Collapse
Affiliation(s)
| | - Ainhoa Indurain
- Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden.,Department of Nephrology, Linköping University Hospital, Linköping, Sweden.,Department of Acute Internal Medicine and Geriatrics, Linköping University Hospital, Linköping, Sweden
| | - Thobias Romu
- AMRA Medical AB, Linköping, Sweden.,Department of Biomedical Engineering, Linköping University, Linköping, Sweden.,Center for Medical Image Science and Visualization, Linköping University, Linköping, Sweden
| | | | - Mårten Segelmark
- Department of Clinical Sciences, Lund University, Lund, Sweden.,Division of Nephrology Lund, Skåne University Hospital, Lund, Sweden
| | - Fredrik Uhlin
- Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden.,Department of Nephrology, Linköping University Hospital, Linköping, Sweden.,Department of Health Technologies, Tallinn University of Technology, Tallinn, Estonia
| | - Anders Fernström
- Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden.,Department of Nephrology, Linköping University Hospital, Linköping, Sweden
| | - Olof Dahlqvist Leinhard
- AMRA Medical AB, Linköping, Sweden.,Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden.,Center for Medical Image Science and Visualization, Linköping University, Linköping, Sweden
| |
Collapse
|
4
|
Portable NMR for quantification of breast density in vivo: Proof-of-concept measurements and comparison with quantitative MRI. Magn Reson Imaging 2022; 92:212-223. [PMID: 35843446 DOI: 10.1016/j.mri.2022.07.004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Revised: 06/17/2022] [Accepted: 07/11/2022] [Indexed: 11/23/2022]
Abstract
Mammographic Density (MD) is the degree of radio-opacity of the breast in an X-ray mammogram. It is determined by the Fibroglandular: Adipose tissue ratio. MD has major implications in breast cancer risk and breast cancer chemoprevention. This study aimed to investigate the feasibility of accurate, low-cost quantification of MD in vivo without ionising radiation. We used single-sided portable nuclear magnetic resonance ("Portable NMR") due to its low cost and the absence of radiation-related safety concerns. Fifteen (N = 15) healthy female volunteers were selected for the study and underwent an imaging routine consisting of 2D X-ray mammography, quantitative breast 3T MRI (Dixon and T1-based 3D compositional breast imaging), and 1D compositional depth profiling of the right breast using Portable NMR. For each participant, all the measurements were made within 3-4 h of each other. MRI-determined tissue water content was used as the MD-equivalent quantity. Portable NMR depth profiles of tissue water were compared with the equivalent depth profiles reconstructed from Dixon and T1-based MR images, which were used as the MD-equivalent reference standard. The agreement between the depth profiles acquired using Portable NMR and the reconstructed reference-standard profiles was variable but overall encouraging. The agreement was somewhat inferior to that seen in breast tissue explant measurements conducted in vitro, where quantitative micro-CT was used as the reference standard. The lower agreement in vivo can be attributed to an uncertainty in the positioning of the Portable NMR sensor on the breast surface and breast compression in Portable NMR measurements. The degree of agreement between Portable NMR and quantitative MRI is encouraging. While the results call for further development of quantitative Portable NMR, they demonstrate the in-principle feasibility of Portable NMR-based quantitative compositional imaging in vivo and show promise for the development of safe and low-cost protocols for quantification of MD suitable for clinical applications.
Collapse
|
5
|
Aronson D. The interstitial compartment as a therapeutic target in heart failure. Front Cardiovasc Med 2022; 9:933384. [PMID: 36061549 PMCID: PMC9428749 DOI: 10.3389/fcvm.2022.933384] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2022] [Accepted: 07/15/2022] [Indexed: 12/23/2022] Open
Abstract
Congestion is the single most important contributor to heart failure (HF) decompensation. Most of the excess volume in patients with HF resides in the interstitial compartment. Inadequate decongestion implies persistent interstitial congestion and is associated with worse outcomes. Therefore, effective interstitial decongestion represents an unmet need to improve quality of life and reduce clinical events. The key processes that underlie incomplete interstitial decongestion are often ignored. In this review, we provide a summary of the pathophysiology of the interstitial compartment in HF and the factors governing the movement of fluids between the interstitial and vascular compartments. Disruption of the extracellular matrix compaction occurs with edema, such that the interstitium becomes highly compliant, and large changes in volume marginally increase interstitial pressure and allow progressive capillary filtration into the interstitium. Augmentation of lymph flow is required to prevent interstitial edema, and the lymphatic system can increase fluid removal by at least 10-fold. In HF, lymphatic remodeling can become insufficient or maladaptive such that the capacity of the lymphatic system to remove fluid from the interstitium is exceeded. Increased central venous pressure at the site of the thoracic duct outlet also impairs lymphatic drainage. Owing to the kinetics of extracellular fluid, microvascular absorption tends to be transient (as determined by the revised Starling equation). Therefore, effective interstitial decongestion with adequate transcapillary plasma refill requires a substantial reduction in plasma volume and capillary pressure that are prolonged and sustained, which is not always achieved in clinical practice. The critical importance of the interstitium in the congestive state underscores the need to directly decongest the interstitial compartment without relying on the lowering of intracapillary pressure with diuretics. This unmet need may be addressed by novel device therapies in the near future.
Collapse
Affiliation(s)
- Doron Aronson
- Department of Cardiology, Rambam Health Care Campus, B. Rappaport Faculty of Medicine, Technion Medical School, Haifa, Israel
| |
Collapse
|
6
|
Lang M, Rapalino O, Huang S, Lev MH, Conklin J, Wald LL. Emerging Techniques and Future Directions: Fast and Portable Magnetic Resonance Imaging. Magn Reson Imaging Clin N Am 2022; 30:565-582. [PMID: 35995480 DOI: 10.1016/j.mric.2022.05.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Fast MRI and portable MRI are emerging as promising technologies to improve the speed, efficiency, and availability of MR imaging. Fast MRI methods are increasingly being adopted to create screening protocols for the diagnosis and management of acute pathology in the emergency department. Faster imaging can facilitate timely diagnosis, reduce motion artifacts, and improve departmental MR operations. Point-of-care and portable MRI are emerging technologies that require radiologists to reenvision the role of MRI as a tool with greater accessibility, fewer siting constraints, and the ability to provide valuable diagnostic information at the bedside. Recently introduced commercially available pulse sequences and new MRI scanners are bringing these technologies closer to the patient's clinical setting, and we expect their use to only increase over the coming decade. This article provides an overview of these emerging technologies for emergency radiologists.
Collapse
Affiliation(s)
- Min Lang
- Department of Radiology, Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA
| | - Otto Rapalino
- Department of Radiology, Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA
| | - Susie Huang
- Department of Radiology, Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA; Athinoula A. Martinos Center for Biomedical Imaging, 149 13th Street, Charleston, MA 02129, USA
| | - Michael H Lev
- Department of Radiology, Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA
| | - John Conklin
- Department of Radiology, Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA.
| | - Lawrence L Wald
- Department of Radiology, Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA; Athinoula A. Martinos Center for Biomedical Imaging, 149 13th Street, Charleston, MA 02129, USA
| |
Collapse
|
7
|
Son HE, Ryu JY, Lee K, Choi YI, Kim MS, Park I, Shin GT, Kim H, Ahn C, Kim S, Chin HJ, Na KY, Chae DW, Ahn S, Hwang SS, Jeong JC. The importance of muscle mass in predicting intradialytic hypotension in patients undergoing maintenance hemodialysis. Kidney Res Clin Pract 2022; 41:611-622. [PMID: 35545221 PMCID: PMC9576459 DOI: 10.23876/j.krcp.21.153] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2021] [Accepted: 02/08/2022] [Indexed: 11/04/2022] Open
Abstract
Background Patients undergoing hemodialysis are susceptible to sarcopenia. As intracellular reservoirs of water, skeletal muscles are important contributors to intradialytic hypotension. This study was designed to determine the role of skeletal muscle mass in intradialytic hypotension. Methods In a cross-sectional study, the body composition of 177 patients was measured immediately after hemodialysis using bioelectrical impedance analysis. The parameters measured were skeletal muscle mass, intracellular and extracellular water contents, total body water, and cell-membrane functionality (in phase angle at 50 kHz). Data from laboratory tests, chest radiography, measurements of handgrip strength and mid-arm circumference, and questionnaires were collected. The main outcome was intradialytic hypotension, defined as more than two episodes of hypotension (systolic blood pressure of <90 mmHg) with intervention over the 3 months following enrollment. Logistic regression models including each parameter related to sarcopenia were compared with a clinical model. Results Patients with a low ratio of skeletal muscle mass to dry body weight (SMM/WT) had a higher rate of intradialytic hypotension (41%). Most low-SMM/WT patients were female, obese, diabetic, and had a lower handgrip strength compared with the other patients. In the high-SMM/WT group, the risk of intradialytic hypotension was lower, with an odds ratio of 0.08 (95% confidence interval [CI], 0.02-0.28) and adjusted odds ratio of 0.06 (95% CI, 0.01-0.29). Conclusion Measurement and maintenance of skeletal muscle can help prevent intradialytic hypotension in frail patients undergoing hemodialysis.
Collapse
Affiliation(s)
- Hyung Eun Son
- Division of Nephrology, Department of Internal Medicine, Seoul National University Bundang Hospital, Seongnam, Republic of Korea
| | - Ji Young Ryu
- Division of Nephrology, Department of Internal Medicine, Seoul National University Bundang Hospital, Seongnam, Republic of Korea
| | - Kyunghoon Lee
- Department of Laboratory Medicine, Seoul National University Bundang Hospital, Seongnam, Republic of Korea
| | | | - Myeong Sung Kim
- Gojan Myeong Internal Medicine Clinic, Ansan, Republic of Korea
| | - Inwhee Park
- Division of Nephrology, Department of Internal Medicine, Ajou University Hospital, Suwon, Republic of Korea.,Department of Internal Medicine, Ajou University School of Medicine, Suwon, Republic of Korea
| | - Gyu Tae Shin
- Division of Nephrology, Department of Internal Medicine, Ajou University Hospital, Suwon, Republic of Korea.,Department of Internal Medicine, Ajou University School of Medicine, Suwon, Republic of Korea
| | - Heungsoo Kim
- Division of Nephrology, Department of Internal Medicine, Ajou University Hospital, Suwon, Republic of Korea.,Department of Internal Medicine, Ajou University School of Medicine, Suwon, Republic of Korea
| | - Curie Ahn
- Division of Nephrology, Department of Internal Medicine, Seoul National University Hospital, Seoul, Republic of Korea.,Department of Internal Medicine, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - Sejoong Kim
- Division of Nephrology, Department of Internal Medicine, Seoul National University Bundang Hospital, Seongnam, Republic of Korea.,Department of Internal Medicine, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - Ho Jun Chin
- Division of Nephrology, Department of Internal Medicine, Seoul National University Bundang Hospital, Seongnam, Republic of Korea.,Department of Internal Medicine, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - Ki Young Na
- Division of Nephrology, Department of Internal Medicine, Seoul National University Bundang Hospital, Seongnam, Republic of Korea.,Department of Internal Medicine, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - Dong-Wan Chae
- Division of Nephrology, Department of Internal Medicine, Seoul National University Bundang Hospital, Seongnam, Republic of Korea.,Department of Internal Medicine, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - Soyeon Ahn
- Medical Research Collaborating Center, Seoul National University Bundang Hospital, Seongnam, Republic of Korea
| | - Seung Sik Hwang
- Department of Public Health Science, School of Public Health, Seoul National University, Seoul, Republic of Korea
| | - Jong Cheol Jeong
- Division of Nephrology, Department of Internal Medicine, Seoul National University Bundang Hospital, Seongnam, Republic of Korea.,Department of Internal Medicine, Seoul National University College of Medicine, Seoul, Republic of Korea
| |
Collapse
|
8
|
|
9
|
Kikuchi J, Yamada S. The exposome paradigm to predict environmental health in terms of systemic homeostasis and resource balance based on NMR data science. RSC Adv 2021; 11:30426-30447. [PMID: 35480260 PMCID: PMC9041152 DOI: 10.1039/d1ra03008f] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2021] [Accepted: 08/31/2021] [Indexed: 12/22/2022] Open
Abstract
The environment, from microbial ecosystems to recycled resources, fluctuates dynamically due to many physical, chemical and biological factors, the profile of which reflects changes in overall state, such as environmental illness caused by a collapse of homeostasis. To evaluate and predict environmental health in terms of systemic homeostasis and resource balance, a comprehensive understanding of these factors requires an approach based on the "exposome paradigm", namely the totality of exposure to all substances. Furthermore, in considering sustainable development to meet global population growth, it is important to gain an understanding of both the circulation of biological resources and waste recycling in human society. From this perspective, natural environment, agriculture, aquaculture, wastewater treatment in industry, biomass degradation and biodegradable materials design are at the forefront of current research. In this respect, nuclear magnetic resonance (NMR) offers tremendous advantages in the analysis of samples of molecular complexity, such as crude bio-extracts, intact cells and tissues, fibres, foods, feeds, fertilizers and environmental samples. Here we outline examples to promote an understanding of recent applications of solution-state, solid-state, time-domain NMR and magnetic resonance imaging (MRI) to the complex evaluation of organisms, materials and the environment. We also describe useful databases and informatics tools, as well as machine learning techniques for NMR analysis, demonstrating that NMR data science can be used to evaluate the exposome in both the natural environment and human society towards a sustainable future.
Collapse
Affiliation(s)
- Jun Kikuchi
- Environmental Metabolic Analysis Research Team, RIKEN Center for Sustainable Resource Science 1-7-22 Suehiro-cho, Tsurumi-ku Yokohama 230-0045 Japan
- Graduate School of Bioagricultural Sciences, Nagoya University Furo-cho, Chikusa-ku Nagoya 464-8601 Japan
- Graduate School of Medical Life Science, Yokohama City University 1-7-29 Suehiro-cho, Tsurumi-ku Yokohama 230-0045 Japan
| | - Shunji Yamada
- Environmental Metabolic Analysis Research Team, RIKEN Center for Sustainable Resource Science 1-7-22 Suehiro-cho, Tsurumi-ku Yokohama 230-0045 Japan
- Prediction Science Laboratory, RIKEN Cluster for Pioneering Research 7-1-26 Minatojima-minami-machi, Chuo-ku Kobe 650-0047 Japan
- Data Assimilation Research Team, RIKEN Center for Computational Science 7-1-26 Minatojima-minami-machi, Chuo-ku Kobe 650-0047 Japan
| |
Collapse
|
10
|
Bennet D, Khorsandian Y, Pelusi J, Mirabella A, Pirrotte P, Zenhausern F. Molecular and physical technologies for monitoring fluid and electrolyte imbalance: A focus on cancer population. Clin Transl Med 2021; 11:e461. [PMID: 34185420 PMCID: PMC8214861 DOI: 10.1002/ctm2.461] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2021] [Revised: 05/11/2021] [Accepted: 05/29/2021] [Indexed: 12/23/2022] Open
Abstract
Several clinical examinations have shown the essential impact of monitoring (de)hydration (fluid and electrolyte imbalance) in cancer patients. There are multiple risk factors associated with (de)hydration, including aging, excessive or lack of fluid consumption in sports, alcohol consumption, hot weather, diabetes insipidus, vomiting, diarrhea, cancer, radiation, chemotherapy, and use of diuretics. Fluid and electrolyte imbalance mainly involves alterations in the levels of sodium, potassium, calcium, and magnesium in extracellular fluids. Hyponatremia is a common condition among individuals with cancer (62% of cases), along with hypokalemia (40%), hypophosphatemia (32%), hypomagnesemia (17%), hypocalcemia (12%), and hypernatremia (1-5%). Lack of hydration and monitoring of hydration status can lead to severe complications, such as nausea/vomiting, diarrhea, fatigue, seizures, cell swelling or shrinking, kidney failure, shock, coma, and even death. This article aims to review the current (de)hydration (fluid and electrolyte imbalance) monitoring technologies focusing on cancer. First, we discuss the physiological and pathophysiological implications of fluid and electrolyte imbalance in cancer patients. Second, we explore the different molecular and physical monitoring methods used to measure fluid and electrolyte imbalance and the measurement challenges in diverse populations. Hydration status is assessed in various indices; plasma, sweat, tear, saliva, urine, body mass, interstitial fluid, and skin-integration techniques have been extensively investigated. No unified (de)hydration (fluid and electrolyte imbalance) monitoring technology exists for different populations (including sports, elderly, children, and cancer). Establishing novel methods and technologies to facilitate and unify measurements of hydration status represents an excellent opportunity to develop impactful new approaches for patient care.
Collapse
Affiliation(s)
- Devasier Bennet
- Center for Applied NanoBioscience and MedicineThe University of ArizonaCollege of MedicinePhoenixUSA
| | - Yasaman Khorsandian
- Center for Applied NanoBioscience and MedicineThe University of ArizonaCollege of MedicinePhoenixUSA
| | | | | | - Patrick Pirrotte
- Collaborative Center for Translational Mass SpectrometryTranslational Genomics Research InstitutePhoenixUSA
| | - Frederic Zenhausern
- Center for Applied NanoBioscience and MedicineThe University of ArizonaCollege of MedicinePhoenixUSA
- HonorHealth Research InstituteScottsdaleUSA
- Collaborative Center for Translational Mass SpectrometryTranslational Genomics Research InstitutePhoenixUSA
| |
Collapse
|
11
|
Bashyam A, Frangieh CJ, Raigani S, Sogo J, Bronson RT, Uygun K, Yeh H, Ausiello DA, Cima MJ. A portable single-sided magnetic-resonance sensor for the grading of liver steatosis and fibrosis. Nat Biomed Eng 2020; 5:240-251. [PMID: 33257853 DOI: 10.1038/s41551-020-00638-0] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2019] [Accepted: 09/28/2020] [Indexed: 12/19/2022]
Abstract
Low-cost non-invasive diagnostic tools for staging the progression of non-alcoholic chronic liver failure from fatty liver disease to steatohepatitis are unavailable. Here, we describe the development and performance of a portable single-sided magnetic-resonance sensor for grading liver steatosis and fibrosis using diffusion-weighted multicomponent T2 relaxometry. In a diet-induced mouse model of non-alcoholic fatty liver disease, the sensor achieved overall accuracies of 92% (Cohen's kappa, κ = 0.89) and 86% (κ = 0.78) in the ex vivo grading of steatosis and fibrosis, respectively. Localization of the measurements in living mice through frequency-dependent spatial encoding led to an overall accuracy of 87% (κ = 0.81) for the grading of steatosis. In human liver samples, the sensor graded steatosis with an overall accuracy of 93% (κ = 0.88). The use of T2 relaxometry as a sensitive measure in fully automated low-cost magnetic-resonance devices at the point of care would alleviate the accessibility and cost limits of magnetic-resonance imaging for diagnosing liver disease and assessing liver health before liver transplantation.
Collapse
Affiliation(s)
- Ashvin Bashyam
- David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA, USA.,Electrical Engineering & Computer Science, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Chris J Frangieh
- David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA, USA.,Electrical Engineering & Computer Science, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Siavash Raigani
- Division of Transplantation, Department of Surgery, Massachusetts General Hospital, Boston, MA, USA
| | - Jeremy Sogo
- David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA, USA.,Electrical Engineering & Computer Science, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Roderick T Bronson
- Department of Microbiology and Immunobiology, Division of Immunology, Harvard Medical School, Boston, MA, USA
| | - Korkut Uygun
- Center for Engineering in Medicine and Surgery, Massachusetts General Hospital, Boston, MA, USA
| | - Heidi Yeh
- Division of Transplantation, Department of Surgery, Massachusetts General Hospital, Boston, MA, USA
| | - Dennis A Ausiello
- Division of Nephrology, Department of Medicine, Massachusetts General Hospital, Boston, MA, USA.,Center for Assessment Technology and Continuous Health, Massachusetts General Hospital, Boston, MA, USA
| | - Michael J Cima
- David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA, USA. .,Department of Materials Science and Engineering, Massachusetts Institute of Technology, Cambridge, MA, USA.
| |
Collapse
|
12
|
Realtime optimization of multidimensional NMR spectroscopy on embedded sensing devices. Sci Rep 2019; 9:17486. [PMID: 31767936 PMCID: PMC6877539 DOI: 10.1038/s41598-019-53929-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2019] [Accepted: 11/07/2019] [Indexed: 01/27/2023] Open
Abstract
The increasingly ubiquitous use of embedded devices calls for autonomous optimizations of sensor performance with meager computing resources. Due to the heavy computing needs, such optimization is rarely performed, and almost never carried out on-the-fly, resulting in a vast underutilization of deployed assets. Aiming at improving the measurement efficiency, we show an OED (Optimal Experimental Design) routine where quantities of interest of probable samples are partitioned into distinctive classes, with the corresponding sensor signals learned by supervised learning models. The trained models, digesting the compressed live data, are subsequently executed at the constrained device for continuous classification and optimization of measurements. We demonstrate the closed-loop method with multidimensional NMR (Nuclear Magnetic Resonance) relaxometry, an analytical technique seeing a substantial growth of field applications in recent years, on a wide range of complex fluids. The realtime portion of the procedure demands minimal computing load, and is ideally suited for instruments that are widely used in remote sensing and IoT networks.
Collapse
|
13
|
Greer M, Chen C, Mandal S. An easily reproducible, hand-held, single-sided, MRI sensor. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2019; 308:106591. [PMID: 31546179 DOI: 10.1016/j.jmr.2019.106591] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/13/2019] [Revised: 08/29/2019] [Accepted: 09/03/2019] [Indexed: 06/10/2023]
Abstract
Single-sided MRI sensors allow the imaging of samples that are larger than the magnet. Thus, they enable truly portable imagers with potential applications in medicine, quality assurance (QA), agriculture, material science, and other fields. However, despite recent advancements, single-sided MRI systems are relatively uncommon. This is partially due to the limited number of commercial products. Also, current implementations often require large and/or complex magnet arrays which require machining techniques such as milling or drilling. These techniques must be performed to tight tolerances to ensure accuracy of the B0 field. Furthermore, these systems generally have hand-wound RF or gradient coils that are not trivial to construct. The main goals of this work are to reduce the size of single-sided MRI sensors while simultaneously making them more accessible for others to build. To this end, we present a hand-held, single-sided, MRI sensor that is constructed using an easy-to-assemble magnet array, a 3D-printed housing, and printed circuit boards (PCBs) that contain the RF coil, gradient coils, and matching network. By implementing all coils directly on PCBs, the geometry can be easily optimized and then manufactured at low cost. Both spin density-weighted and T1-weighted images of various samples are presented to demonstrate the capabilities of the proposed sensor.
Collapse
Affiliation(s)
- Mason Greer
- Case Western Reserve University, 10900 Euclid Ave, Cleveland, OH 44106, USA.
| | - Cheng Chen
- Case Western Reserve University, 10900 Euclid Ave, Cleveland, OH 44106, USA.
| | - Soumyajit Mandal
- Case Western Reserve University, 10900 Euclid Ave, Cleveland, OH 44106, USA.
| |
Collapse
|
14
|
Bashyam A, Frangieh CJ, Li M, Cima MJ. Dehydration assessment via a portable, single sided magnetic resonance sensor. Magn Reson Med 2019; 83:1390-1404. [PMID: 31631380 DOI: 10.1002/mrm.28004] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2019] [Revised: 08/21/2019] [Accepted: 08/28/2019] [Indexed: 12/20/2022]
Abstract
PURPOSE Undiagnosed dehydration compromises health outcomes across many populations. Existing dehydration diagnostics require invasive bodily fluid sampling or are easily confounded by fluid and electrolyte intake, environment, and physical activity limiting widespread adoption. We present a portable MR sensor designed to measure intramuscular fluid shifts to identify volume depletion. METHODS Fluid loss is induced via a mouse model of thermal dehydration (37°C; 15-20% relative humidity). We demonstrate quantification of fluid loss induced by hyperosmotic dehydration with multicomponent T2 relaxometry using both a benchtop NMR system and MRI localized to skeletal muscle tissue. We then describe a miniaturized (~1000 cm3 ) portable (~4 kg) MR sensor (0.28 T) designed to identify dehydration-induced fluid loss. T2 relaxometry measurements were performed using a Carr-Purcell-Meiboom-Gill pulse sequence in ~4 min. RESULTS T2 values from the portable MR sensor exhibited strong (R2 = 0.996) agreement with benchtop NMR spectrometer. Thermal dehydration induced weight loss of 4 to 11% over 5 to 10 h. Fluid loss induced by thermal dehydration was accurately identified via whole-animal NMR and skeletal muscle. The portable MR sensor accurately identified dehydration via multicomponent T2 relaxometry. CONCLUSION Performing multicomponent T2 relaxometry localized to the skeletal muscle with a miniaturized MR sensor provides a noninvasive, physiologically relevant measure of dehydration induced fluid loss in a mouse model. This approach offers sensor portability, reduced system complexity, fully automated operation, and low cost compared with MRI. This approach may serve as a versatile and portable point of care technique for dehydration monitoring.
Collapse
Affiliation(s)
- Ashvin Bashyam
- David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, Massachusetts.,Department of Electrical Engineering & Computer Science, Massachusetts Institute of Technology, Cambridge, Massachusetts
| | - Chris J Frangieh
- David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, Massachusetts.,Department of Electrical Engineering & Computer Science, Massachusetts Institute of Technology, Cambridge, Massachusetts
| | - Matthew Li
- David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, Massachusetts.,Harvard-MIT Program in Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, Massachusetts
| | - Michael J Cima
- David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, Massachusetts.,Department of Materials Science and Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts
| |
Collapse
|