1
|
Zhou Y, Leahy K, Grose A, Lykins J, Siddiqui M, Leong N, Goodall P, Withers S, Ashi K, Schrantz S, Tesic V, Abeleda AP, Beavis K, Clouser F, Ismail M, Christmas M, Piarroux R, Limonne D, Chapey E, Abraham S, Baird I, Thibodeau J, Boyer KM, Torres E, Conrey S, Wang K, Staat MA, Back N, L’Ollivier C, Mahinc C, Flori P, Gomez-Marin J, Peyron F, Houzé S, Wallon M, McLeod R. Novel paradigm enables accurate monthly gestational screening to prevent congenital toxoplasmosis and more. PLoS Negl Trop Dis 2024; 18:e0011335. [PMID: 38805559 PMCID: PMC11132520 DOI: 10.1371/journal.pntd.0011335] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Accepted: 04/01/2024] [Indexed: 05/30/2024] Open
Abstract
BACKGROUND Congenital toxoplasmosis is a treatable, preventable disease, but untreated causes death, prematurity, loss of sight, cognition and motor function, and substantial costs worldwide. OBJECTIVES We asked whether high performance of an Immunochromatographic-test (ICT) could enable accurate, rapid diagnosis/treatment, establishing new, improved care-paradigms at point-of-care and clinical laboratory. METHODS Data were obtained in 12 studies/analyses addressing: 1-feasibility/efficacy; 2-false-positives; 3-acceptability; 4-pink/black-line/all studies; 5-time/cost; 6-Quick-Information/Limit-of-detection; 7, 8-acute;-chronic; 9-epidemiology; 10-ADBio; 11,12-Commentary/Cases/Chronology. FINDINGS ICT was compared with gold-standard or predicate-tests. Overall, ICT performance for 1093 blood/4967 sera was 99.2%/97.5% sensitive and 99.0%/99.7% specific. However, in clinical trial, FDA-cleared-predicate tests initially caused practical, costly problems due to false-positive-IgM results. For 58 persons, 3/43 seronegative and 2/15 chronically infected persons had false positive IgM predicate tests. This caused substantial anxiety, concerns, and required costly, delayed confirmation in reference centers. Absence of false positive ICT results contributes to solutions: Lyon and Paris France and USA Reference laboratories frequently receive sera with erroneously positive local laboratory IgM results impeding patient care. Therefore, thirty-two such sera referred to Lyon's Reference laboratory were ICT-tested. We collated these with other earlier/ongoing results: 132 of 137 USA or French persons had false-positive local laboratory IgM results identified correctly as negative by ICT. Five false positive ICT results in Tunisia and Marseille, France, emphasize need to confirm positive ICT results with Sabin-Feldman-Dye-test or western blot. Separate studies demonstrated high performance in detecting acute infections, meeting FDA, CLIA, WHO REASSURED, CEMark criteria and patient and physician satisfaction with monthly-gestational-ICT-screening. CONCLUSIONS/SIGNIFICANCE This novel paradigm using ICT identifies likely false positives or raises suspicion that a result is truly positive, rapidly needing prompt follow up and treatment. Thus, ICT enables well-accepted gestational screening programs that facilitate rapid treatment saving lives, sight, cognition and motor function. This reduces anxiety, delays, work, and cost at point-of-care and clinical laboratories. TRIAL REGISTRATION NCT04474132, https://clinicaltrials.gov/study/NCT04474132 ClinicalTrials.gov.
Collapse
Affiliation(s)
- Ying Zhou
- Departments of Ophthalmology and Visual Science, The University of Chicago, Chicago, Illinois, United States of America
| | - Karen Leahy
- Department of Obstetrics and Gynecology, The University of Chicago, Chicago, Illinois, United States of America
| | - Andrew Grose
- Departments of Ophthalmology and Visual Science, The University of Chicago, Chicago, Illinois, United States of America
- Pritzker School of Medicine, Division of Infectious Diseases, The University of Chicago, Chicago, Illinois, United States of America
| | - Joseph Lykins
- Departments of Ophthalmology and Visual Science, The University of Chicago, Chicago, Illinois, United States of America
- Pritzker School of Medicine, Division of Infectious Diseases, The University of Chicago, Chicago, Illinois, United States of America
| | - Maryam Siddiqui
- Department of Obstetrics and Gynecology, The University of Chicago, Chicago, Illinois, United States of America
| | - Nicole Leong
- Department of Obstetrics and Gynecology, The University of Chicago, Chicago, Illinois, United States of America
| | - Perpetua Goodall
- Department of Obstetrics and Gynecology, The University of Chicago, Chicago, Illinois, United States of America
| | - Shawn Withers
- Departments of Ophthalmology and Visual Science, The University of Chicago, Chicago, Illinois, United States of America
| | - Kevin Ashi
- Departments of Ophthalmology and Visual Science, The University of Chicago, Chicago, Illinois, United States of America
- Pritzker School of Medicine, Division of Infectious Diseases, The University of Chicago, Chicago, Illinois, United States of America
| | - Stephen Schrantz
- Pritzker School of Medicine, Division of Infectious Diseases, The University of Chicago, Chicago, Illinois, United States of America
- Chicago Medicine, The University of Chicago, Chicago, Illinois, United States of America
- Department of Pediatrics, Division of Infectious Diseases, The University of Chicago, Chicago, Illinois, United States of America
- Department of Medicine, The University of Chicago, Chicago, Illinois, United States of America
| | - Vera Tesic
- Pritzker School of Medicine, Division of Infectious Diseases, The University of Chicago, Chicago, Illinois, United States of America
- Chicago Medicine, The University of Chicago, Chicago, Illinois, United States of America
- Department of Pathology, The University of Chicago, Chicago, Illinois, United States of America
| | - Ana Precy Abeleda
- Chicago Medicine, The University of Chicago, Chicago, Illinois, United States of America
- Department of Pathology, The University of Chicago, Chicago, Illinois, United States of America
| | - Kathleen Beavis
- Pritzker School of Medicine, Division of Infectious Diseases, The University of Chicago, Chicago, Illinois, United States of America
- Chicago Medicine, The University of Chicago, Chicago, Illinois, United States of America
- Department of Pathology, The University of Chicago, Chicago, Illinois, United States of America
| | - Fatima Clouser
- Departments of Ophthalmology and Visual Science, The University of Chicago, Chicago, Illinois, United States of America
| | - Mahmoud Ismail
- Department of Obstetrics and Gynecology, The University of Chicago, Chicago, Illinois, United States of America
- Pritzker School of Medicine, Division of Infectious Diseases, The University of Chicago, Chicago, Illinois, United States of America
- Chicago Medicine, The University of Chicago, Chicago, Illinois, United States of America
| | - Monica Christmas
- Department of Obstetrics and Gynecology, The University of Chicago, Chicago, Illinois, United States of America
- Pritzker School of Medicine, Division of Infectious Diseases, The University of Chicago, Chicago, Illinois, United States of America
- Chicago Medicine, The University of Chicago, Chicago, Illinois, United States of America
| | | | | | - Emmanuelle Chapey
- Institut des agents infectieux, Hôpital de la Croix-Rousse, Lyon, France
| | - Sylvie Abraham
- Laboratory of Parasitologie, Bichat-Claude Bernard Hôpital, Paris, France
| | - Isabelle Baird
- The College, The University of Chicago, Chicago, Illinois, United States of America
- Global Health Center, The University of Chicago, Chicago, Illinois, United States of America
| | - Juliette Thibodeau
- The College, The University of Chicago, Chicago, Illinois, United States of America
- Global Health Center, The University of Chicago, Chicago, Illinois, United States of America
| | - Kenneth M. Boyer
- Department of Pediatrics, Division of Infectious Diseases, Rush Presbyterian Hospital and Medical Center, Chicago, Illinois, United States of America
| | - Elizabeth Torres
- Group of Molecular Parasitology (GEPAMOL), Center of Biomedical Research, Faculty of Health Sciences, University of Quindio, Armenia (Quindio), Colombia
| | - Shannon Conrey
- University of Cincinnati and Cincinnati Children’s Hospital Medical Center, University of Cincinnati, Cincinnati, Ohio, United States of America
| | - Kanix Wang
- Carl H. Lindner College of Business, The University of Cincinnati, Cincinnati, Ohio, United States of America
| | - Mary Allen Staat
- University of Cincinnati and Cincinnati Children’s Hospital Medical Center, University of Cincinnati, Cincinnati, Ohio, United States of America
| | - Nancy Back
- University of Cincinnati and Cincinnati Children’s Hospital Medical Center, University of Cincinnati, Cincinnati, Ohio, United States of America
| | - Coralie L’Ollivier
- Centre National de Référence Toxoplasmose—Pôle Sérologie, Hôpitaux Universitaires de Strasbourg, Strasbourg, France
- IHU-Méditerranée Infection, Assistance Publique Hôpitaux de Marseille (AP-HM), Marseille, France; Aix Marseille University, IRD, AP-HM, SSA, VITROME, IHU Méditerranée, Marseille, France
| | - Caroline Mahinc
- Parasitology and Mycology Laboratory, Pôle de Biologie-Pathologie, University Hospital of Saint Etienne, Saint Etienne, France
| | - Pierre Flori
- Parasitology and Mycology Laboratory, Pôle de Biologie-Pathologie, University Hospital of Saint Etienne, Saint Etienne, France
| | - Jorge Gomez-Marin
- Group of Molecular Parasitology (GEPAMOL), Center of Biomedical Research, Faculty of Health Sciences, University of Quindio, Armenia (Quindio), Colombia
| | - Francois Peyron
- Institut des agents infectieux, Hôpital de la Croix-Rousse, Lyon, France
| | - Sandrine Houzé
- Laboratory of Parasitologie, Bichat-Claude Bernard Hôpital, Paris, France
| | - Martine Wallon
- Institut des agents infectieux, Hôpital de la Croix-Rousse, Lyon, France
| | - Rima McLeod
- Departments of Ophthalmology and Visual Science, The University of Chicago, Chicago, Illinois, United States of America
- Pritzker School of Medicine, Division of Infectious Diseases, The University of Chicago, Chicago, Illinois, United States of America
- Department of Pediatrics, Division of Infectious Diseases, The University of Chicago, Chicago, Illinois, United States of America
- Department of Medicine, The University of Chicago, Chicago, Illinois, United States of America
- The College, The University of Chicago, Chicago, Illinois, United States of America
- Global Health Center, The University of Chicago, Chicago, Illinois, United States of America
| |
Collapse
|
2
|
Voyiatzaki C, Zare Chormizi AD, Tsoumani ME, Efstathiou A, Konstantinidis K, Chaniotis D, Chrysos G, Argyraki A, Papastamopoulos V, Kotsianopoulou M. Seroprevalence of Toxoplasma gondii among HIV Positive Patients under Surveillance in Greek Infectious Disease Units: A Screening Study with Comparative Evaluation of Serological Methods. Pathogens 2024; 13:375. [PMID: 38787227 PMCID: PMC11123859 DOI: 10.3390/pathogens13050375] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2024] [Revised: 04/28/2024] [Accepted: 04/29/2024] [Indexed: 05/25/2024] Open
Abstract
This study aims to screen for IgG antibodies against Toxoplasma gondii (T. gondii) in the sera of 155 newly diagnosed Human Immunodeficiency Virus (HIV) positive patients under surveillance in Greek Infectious Disease Units. Additionally, risk factors based on patient demographics were examined, and a comparative evaluation of commercially available serological methods was conducted. Three methods were employed to detect IgG antibodies against T. gondii: Enzyme-Linked Immunosorbent Assay (ELISA), Indirect Immunofluorescence Antibody Test (IFAT), and Western Blot (WB), which was used as a reference here. Forty-nine sera samples were true-positive for IgG antibodies against T. gondii, resulting in a 31.61% positivity rate, and the immunoassay test statistical reliability analysis resulted in higher IFAT accuracy (90.97%) compared to ELISA (76.26%). Furthermore, statistical analysis of demographic and immunological data included in the study placed female and foreign/non-Greek individuals at 2.24 (p = 0.0009) and 2.34 (p = 0.0006) times higher risk of positive T. gondii IgG testing compared to their male and Greek counterparts, respectively. Our findings on positivity rates and comparative serology underscore the importance of early and suitable screening measures for newly diagnosed HIV+ patients to mitigate the life-threatening outcomes that may arise from a potential subsequent T. gondii activation.
Collapse
Affiliation(s)
- Chrysa Voyiatzaki
- Department of Biomedical Sciences, Division of Medical Laboratories Science, University of West Attica, 12243 Athens, Greece
| | - Apollon Dareios Zare Chormizi
- Department of Biomedical Sciences, Division of Medical Laboratories Science, University of West Attica, 12243 Athens, Greece
| | - Maria E. Tsoumani
- Department of Biomedical Sciences, Division of Medical Laboratories Science, University of West Attica, 12243 Athens, Greece
| | - Antonia Efstathiou
- Department of Biomedical Sciences, Division of Medical Laboratories Science, University of West Attica, 12243 Athens, Greece
- Immunology of Infection Group, Department of Microbiology, Hellenic Pasteur Institute, 11521 Athens, Greece
| | - Konstantinos Konstantinidis
- Department of Medicine, Laboratory of Biology, Democritus University of Thrace, Dragana, 68100 Alexandroupolis, Greece
| | - Dimitrios Chaniotis
- Department of Biomedical Sciences, Division of Medical Laboratories Science, University of West Attica, 12243 Athens, Greece
| | - Georgios Chrysos
- Second Department of Internal Medicine, Tzaneio General Hospital of Piraeus, 18536 Athens, Greece
| | - Aikaterini Argyraki
- Department of Internal Medicine, Sotiria Thoracic Diseases General Hospital, 11527 Athens, Greece
| | - Vasileios Papastamopoulos
- 5th Department of Internal Medicine, Infectious Diseases Unit, Evaggelismos General Hospital, 10676 Athens, Greece
| | - Marika Kotsianopoulou
- Department of Public Health Policy, School of Public Health, University of West Attica, 11521 Athens, Greece
| |
Collapse
|
3
|
Zhou Y, Leahy K, Grose A, Lykins J, Siddiqui M, Leong N, Goodall P, Withers S, Ashi K, Schrantz S, Tesic V, Abeleda AP, Beavis K, Clouser F, Ismail M, Christmas M, Piarroux R, Limonne D, Chapey E, Abraham S, Baird I, Thibodeau J, Boyer K, Torres E, Conrey S, Wang K, Staat MA, Back N, Gomez Marin J, Peyron F, Houze S, Wallon M, McLeod R. Novel paradigm enables accurate monthly gestational screening to prevent congenital toxoplasmosis and more. MEDRXIV : THE PREPRINT SERVER FOR HEALTH SCIENCES 2023:2023.04.26.23289132. [PMID: 37162985 PMCID: PMC10168490 DOI: 10.1101/2023.04.26.23289132] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
Background Congenital toxoplasmosis is a treatable, preventable disease, but untreated causes death, prematurity, loss of sight, cognition and motor function, and substantial costs worldwide. Methods/Findings In our ongoing USA feasibility/efficacy clinical trial, data collated with other ongoing and earlier published results proved high performance of an Immunochromatographic-test(ICT) that enables accurate, rapid diagnosis/treatment, establishing new paradigms for care. Overall results from patient blood and/or serum samples tested with ICT compared with gold-standard-predicate-test results found ICT performance for 4606 sera/1876 blood, 99.3%/97.5% sensitive and 98.9%/99.7% specific. However, in the clinical trial the FDA-cleared-predicate test initially caused practical, costly problems due to false-positive-IgM results. For 58 persons, 3/43 seronegative and 2/15 chronically infected persons had false positive IgM predicate tests. This caused substantial anxiety, concerns, and required costly, delayed confirmation in reference centers. Absence of false positive ICT results contributes to solutions: Lyon and Paris France and USA Reference laboratories frequently receive sera with erroneously positive local laboratory IgM results impeding patient care. Therefore, thirty-two such sera referred to Lyon's Reference laboratory were ICT-tested. We collated these with other earlier/ongoing results: 132 of 137 USA or French persons had false positive local laboratory IgM results identified correctly as negative by ICT. Five false positive ICT results in Tunisia and Marseille, France, emphasize need to confirm positive ICT results with Sabin-Feldman-Dye-test or western blot. Separate studies demonstrated high performance in detecting acute infections, meeting FDA, CLIA, WHO ASSURED, CEMark criteria and patient and physician satisfaction with monthly-gestational-ICT-screening. Conclusions/Significance This novel paradigm using ICT identifies likely false positives or raises suspicion that a result is truly positive, rapidly needing prompt follow up and treatment. Thus, ICT enables well-accepted gestational screening programs that facilitate rapid treatment saving lives, sight, cognition and motor function. This reduces anxiety, delays, work, and cost at point-of-care and clinical laboratories. Author’s Summary Toxoplasmosis is a major health burden for developed and developing countries, causing damage to eyes and brain, loss of life and substantial societal costs. Prompt diagnosis in gestational screening programs enables treatment, thereby relieving suffering, and leading to > 14-fold cost savings for care. Herein, we demonstrate that using an ICT that meets WHO ASSURED-criteria identifying persons with/without antibody to Toxoplasma gondii in sera and whole blood with high sensitivity and specificity, is feasible to use in USA clinical practice. We find this new approach can help to obviate the problem of detection of false positive anti- T.gondii IgM results for those without IgG antibodies to T.gondii when this occurs in present, standard of care, predicate USA FDA cleared available assays. Thus, this accurate test facilitates gestational screening programs and a global initiative to diagnose and thereby prevent and treat T.gondii infection. This minimizes likelihood of false positives (IgG and/or IgM) while maintaining maximum sensitivity. When isolated IgM antibodies are detected, it is necessary to confirm and when indicated continue follow up testing in ∼2 weeks to establish seroconversion. Presence of a positive ICT makes it likely that IgM is truly positive and a negative ICT makes it likely that IgM will be a false positive without infection. These results create a new, enthusiastically-accepted, precise paradigm for rapid diagnosis and validation of results with a second-line test. This helps eliminate alarm and anxiety about false-positive results, while expediting needed treatment for true positive results and providing back up distinguishing false positive tests.
Collapse
|
4
|
Meroni V, Genco F, Scudeller L, Brenier-Pinchart MP, Fricker-Hidalgo H, L’Ollivier C, Paris L, Pelloux H. Diagnostic Accuracy of LDBIO-Toxo II IgG and IgM Western Blot in Suspected Seroconversion in Pregnancy: A Multicentre Study. Pathogens 2022; 11:pathogens11060665. [PMID: 35745519 PMCID: PMC9231380 DOI: 10.3390/pathogens11060665] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2022] [Revised: 06/01/2022] [Accepted: 06/08/2022] [Indexed: 02/01/2023] Open
Abstract
The high sensitivity of the automated tests used for Toxoplasma gondii serology can yield false-positive IgM results due to aspecific reactions. On the other hand, specific therapy can delay IgG production and, therefore, the diagnosis of seroconversion. There is a need for confirmation tests to early detect seroconversions during pregnancy. We conducted a multicentre study to evaluate the diagnostic accuracy of the Toxo II IgG and a new, not yet commercialised Toxo II IgM western blot (WB) (LDBio diagnostics Lyon France) on 229 sera corresponding to 93 patients with seroconversions and 158 sera corresponding to 68 patients with nonspecific IgM. Sensitivity was 97.8% for IgM WB and 98.9% for IgG WB. Specificity was 89.7% and 100%, respectively. The concordance between IgM and IgG Toxo WB with the final diagnosis was very good, K = 0.89 and K = 0.99, respectively. In 5 cases (5.4%), the appearance of IgM, and in 55 cases (59.1%), the appearance of IgG was recorded by WB earlier than by traditional tests. In 10 cases (10.8%), IgM was detected after the traditional tests and in 2 cases (2.2%) for IgG. The association of IgG and IgM WB on the same sample not only detected all seroconversions but also correctly identified most of the false-positive results.
Collapse
Affiliation(s)
- Valeria Meroni
- Department of Molecular Medicine, University of Pavia, 27100 Pavia, Italy;
| | - Francesca Genco
- Microbiology and Virology Unit, Fondazione IRCCS San Matteo Hospital Foundation, 27100 Pavia, Italy;
| | - Luigia Scudeller
- UOC Innovation and Research, IRCCS University Hospital Sant’Orsola, 40138 Bologna, Italy;
| | - Marie-Pierre Brenier-Pinchart
- Parasitology-Mycology, University Hospital and Grenoble-Alpes University, 38043 Grenoble, France; (M.-P.B.-P.); (H.F.-H.); (H.P.)
| | - Hélène Fricker-Hidalgo
- Parasitology-Mycology, University Hospital and Grenoble-Alpes University, 38043 Grenoble, France; (M.-P.B.-P.); (H.F.-H.); (H.P.)
| | - Coralie L’Ollivier
- Aix Marseille Univ, IRD, AP-HM, SSA, VITROME, IHU Méditerranée, 13005 Marseille, France;
| | - Luc Paris
- APHP-Sorbonne Université, Parasitology-Mycology, Pitié-Salpêtrière Hospital, 75013 Paris, France
- Correspondence: ; Tel.: +33-(0)1-42-16-01-60
| | - Hervé Pelloux
- Parasitology-Mycology, University Hospital and Grenoble-Alpes University, 38043 Grenoble, France; (M.-P.B.-P.); (H.F.-H.); (H.P.)
| |
Collapse
|
5
|
Jean-Pierre V, Miozzo J, Fricker-Hidalgo H, Garnaud C, Robert MG, Pelloux H, Brenier-Pinchart MP. Serological diagnosis of toxoplasmosis: evaluation of the commercial test recomLine Toxoplasma IgG immunoblot (Mikrogen) based on recombinant antigens. Parasite 2022; 29:52. [PMCID: PMC9645231 DOI: 10.1051/parasite/2022050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2022] [Accepted: 10/06/2022] [Indexed: 11/11/2022] Open
Abstract
Background: IgG detection to determine immune status to Toxoplasma gondii infection and seroconversion mainly relies on ELISA techniques and, if necessary, on a confirmatory test, Western blot. This study evaluated the performance of the recomLine Toxoplasma IgG immunoblot (IB-recomLine) (Mikrogen) as a confirmatory test on a large number of sera. A total of 171 sera were selected (113 patients) and had previously been analyzed by two ELISA tests, ARCHITECT (Abbott) and VIDAS (bioMérieux) ± LDBIO-Toxo II IgG Western blot (WB-LDBIO) (LDBio). The sera were classified into three groups: group 1 included 50 sera without difficulty in interpreting the IgG results (patients with documented past infection or uninfected); group 2 included 47 sera with difficulty in interpreting the ELISA results; and group 3 included 74 sequential sera from 25 pregnant women with seroconversion. Results: In group 1, overall IgG agreements were 94% and 90% with ARCHITECT and VIDAS, respectively. In group 2, low agreement was observed between IB-recomLine and WB-LDBIO, with eight false-positive and 13 false-negative results. In group 3, 4/13 seroconversions were detected earlier with IB-recomLine compared to other tests. Conclusions: IB-recomLine allowed for earlier diagnosis of toxoplasmic seroconversion compared to both ELISA tests and WB-LDBIO but led to insufficient performance to confirm the immune status when ELISA results were discordant or equivocal.
Collapse
Affiliation(s)
- Vincent Jean-Pierre
- Parasitology-Mycology, Grenoble Alpes University Hospital 38000 Grenoble France
- Corresponding author:
| | - Julien Miozzo
- Parasitology-Mycology, Grenoble Alpes University Hospital 38000 Grenoble France
| | | | - Cécile Garnaud
- Parasitology-Mycology, Grenoble Alpes University Hospital 38000 Grenoble France
- TIMC, CNRS, Université Grenoble Alpes 38000 Grenoble France
| | - Marie Gladys Robert
- Parasitology-Mycology, Grenoble Alpes University Hospital 38000 Grenoble France
| | - Hervé Pelloux
- Parasitology-Mycology, Grenoble Alpes University Hospital 38000 Grenoble France
| | | |
Collapse
|
6
|
Robert-Gangneux F, Guegan H. Anti-Toxoplasma IgG assays: What performances for what purpose? A systematic review. Parasite 2021; 28:39. [PMID: 33904818 PMCID: PMC8078101 DOI: 10.1051/parasite/2021035] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2021] [Accepted: 03/31/2021] [Indexed: 12/27/2022] Open
Abstract
Chronic infection with Toxoplasma gondii is attested by the detection of specific anti-Toxoplasma IgG. A wide panel of serologic methods is currently marketed, and the most suitable method should be chosen according to the laboratory resources and the screened population. This systematic review of evaluation studies aimed at establishing an overview of the performances, i.e. sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of marketed anti-Toxoplasma IgG assays, and discussing their technical characteristics to guide further choice for routine diagnostic use. According to PRISMA guidelines, the search performed in PubMed and Web of Science databases recovered 826 studies, of which 17 were ultimately included. Twenty commercial anti-Toxoplasma IgG assays were evaluated, in comparison with an accepted reference method. Most of them were enzyme-immunoassays (EIAs, n = 12), followed by agglutination tests (n = 4), immunochromatographic tests (n = 3), and a Western-Blot assay (WB, n = 1). The mean sensitivity of IgG assays ranged from 89.7% to 100% for standard titers and from 13.4% to 99.2% for low IgG titers. A few studies pointed out the ability of some methods, especially WB to detect IgG early after primary infection. The specificity of IgG assays was generally high, ranging from 91.3% to 100%; and higher than 99% for most EIA assays. The PPV was not a discriminant indicator among methods, whereas significant disparities (87.5%-100%) were reported among NPVs, a key-parameter assessing the ability to definitively rule out a Toxoplasma infection in patients at-risk for opportunistic infections.
Collapse
Affiliation(s)
- Florence Robert-Gangneux
-
Université de Rennes, CHU Rennes, Inserm, EHESP, Irset (Institut de Recherche en Santé Environnement Travail), UMR_S 1085 35000 Rennes France
| | - Hélène Guegan
-
Université de Rennes, CHU Rennes, Inserm, EHESP, Irset (Institut de Recherche en Santé Environnement Travail), UMR_S 1085 35000 Rennes France
| |
Collapse
|
7
|
Hegazy MM, Hegazy MK, Azab MS, Nabih N. Validation of dried blood spots in monitoring toxoplasmosis. Pathog Glob Health 2020; 114:242-250. [PMID: 32419673 DOI: 10.1080/20477724.2020.1765125] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022] Open
Abstract
Due to the growing importance of toxoplasmosis worldwide, simple methods of diagnosis are important for epidemiologic studies. Dried blood spot (DBS) is a useful tool that surpasses venipuncture. DBS-Toxoplasma testing via a finger-stick could also be used in setting where phlebotomies might not be feasible, such as worldwide prenatal and newborn screening for congenital toxoplasmosis. This study included 101 study subjects were occupationally at-risk to Toxoplasma gondii infection and 33 as controls. Serum was collected from both groups for the detection of anti-Toxoplasma IgG antibodies by ELISA as a reference gold standard test. For the occupational at-risk group, capillary finger stick derived blood was blotted onto five sets of Whatman protein saver cards. Discs were stored as four sets; three sets at 4°C and eluted 1, 2 and 3 months of storage and one set at -20°C for 3 months then eluted. Additionally, one set was eluted immediately. Anti-Toxoplasma IgG antibodies were evaluated by ELISA from DBS eluted samples and compared to matched sera. DBS elutes from discs that were freshly prepared for anti-Toxoplasma IgG showed 100% sensitivity, specificity and diagnostic accuracy. Serologic testing using DBS showed very good diagnostic accuracy under all mentioned conditions of storage. Higher stability was obtained when the blood discs stored at 4°C for 1 month and up to 3 months at -20°C, with 98.18% sensitivity, 100% specificity and 99% diagnostic accuracy. DBS-Toxoplasma testing is characterized by simplicity in performance, cost-effectiveness and the ease of handling, to store and to transport, with high diagnostic accuracy.
Collapse
Affiliation(s)
- Mamdouh M Hegazy
- Department of Medical Parasitology, Faculty of Medicine, Mansoura University , Mansoura, Egypt
| | - Mona K Hegazy
- Department of Medical Parasitology, Faculty of Medicine, Mansoura University , Mansoura, Egypt
| | - Manar S Azab
- Department of Medical Parasitology, Faculty of Medicine, Mansoura University , Mansoura, Egypt
| | - Nairmen Nabih
- Department of Medical Parasitology, Faculty of Medicine, Mansoura University , Mansoura, Egypt
| |
Collapse
|
8
|
Picone O, Fuchs F, Benoist G, Binquet C, Kieffer F, Wallon M, Wehbe K, Mandelbrot L, Villena I. Toxoplasmosis screening during pregnancy in France: Opinion of an expert panel for the CNGOF. J Gynecol Obstet Hum Reprod 2020; 49:101814. [PMID: 32428782 DOI: 10.1016/j.jogoh.2020.101814] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2020] [Accepted: 05/12/2020] [Indexed: 11/15/2022]
Abstract
Prenatal screening to prevent congenital toxoplasmosis as performed in France for several decades has been questioned in view of the decreasing incidence of this infection and the cost of testing. The French College of Obstetrics and Gynecology mandated a multidisciplinary panel of experts to perform a reassessment of the screening program in accordance with international good practice. In France, about 70% of pregnant women are not immune to T. gondii, and 0.2-0.25% become infected during pregnancy. The risk of maternal-fetal transmission of infection is on average 25-29% and depends greatly on the gestational age at seroconversion. In case of fetal transmission, the outcome is livebirth in 95% of cases, with latent congenital toxoplasmosis in 90% of cases and symptomatic forms in 10% of cases, of which 1/3 are severe and 2/3 moderate. Biological techniques have satisfactory performance regarding serologies for the diagnosis of maternal infections and PCR on amniotic fluid for the prenatal diagnosis of congenital toxoplasmosis. Primary prevention of toxoplasmosis is based on hygiene measures that are relatively simple, but poorly implemented. In case of maternal seroconversion, there is a strong case for prenatal prophylactic treatment as soon as possible (ideally within 3 weeks of seroconversion), spiramycin before 14 weeks of gestation (WG), and with a tendency to superiority of the pyrimethamine/sulfadiazine association over spiramycin beyond 14 W G, in order to reduce the risk of symptomatic congenital toxoplasmosis. In case of congenital toxoplasmosis, prompt initiation of treatment reduces the occurrence of cerebral signs and symptoms, as well as retinal lesions. Several medico-economic evaluations of the French toxoplasmosis screening program have been conducted including an individual cost-effectiveness approach with decision analysis which concluded on the profitability of prenatal screening as carried out in France (monthly surveillance of seronegative women, prenatal treatment in case of seroconversion, termination of pregnancy in severe forms). Though most international societies do not recommend systematic screening for mainly financial reasons, if congenital toxoplasmosis appears benign in France today, it is probably thanks to screening and the possibility of early treatment of fetuses and/or newborns. Thus, the panel recommends continuing for now the program in France for prevention of congenital toxoplasmosis.
Collapse
Affiliation(s)
- Olivier Picone
- Assistance Publique-Hôpitaux de Paris, Service de Gynécologie-Obstétrique, Hôpital Louis Mourier, Colombes, France; Université de Paris; Inserm IAME-U1137, Paris, France; FHU PREMA; Groupe de Recherche sur les Infections pendant la grossesse (GRIG)
| | - Florent Fuchs
- Service de Gynécologie Obstétrique CHU de Montpellier, Hopital Arnaud de Villeneuve, Montpellier, France; Inserm, CESP Centre de recherche en Epidémiologie et Santé des Populations, U1018, Reproduction et Développement de l'enfant, 94807 Villejuif, France; EA2415: Aide à la décision médicale Personnalisée, Axe B: Méthode en épidémiologie Clinique, Université de Montpellier
| | | | - Christine Binquet
- Inserm, CIC1432, module Epidémiologie Clinique, Dijon, France; CHU Dijon-Bourgogne, Centre d'Investigation Clinique, Module Epidémiologie Clinique/Essais Cliniques, Dijon, France
| | - François Kieffer
- Assistance Publique-Hôpitaux de Paris, Service de néonatologie, Hôpital Armand Trousseau, Paris, France
| | - Martine Wallon
- Hospices Civils de Lyon, Hôpital de la Croix-Rousse, Service de Parasitologie - Mycologie Médicale, Lyon, France; Université Lyon-1, Equipe Waking, Physiologie Intégrée du Système d'éveil, Centre de Recherche en Neurosciences de Lyon (INSERM U1028 - CNRS UMR 5292), Bron, France
| | - Karl Wehbe
- Centre Hospitalier Universitaire de Strasbourg, Service de Gynécologie-Obstétrique, Strasbourg, France
| | - Laurent Mandelbrot
- Assistance Publique-Hôpitaux de Paris, Service de Gynécologie-Obstétrique, Hôpital Louis Mourier, Colombes, France; Université de Paris; Inserm IAME-U1137, Paris, France; FHU PREMA; Groupe de Recherche sur les Infections pendant la grossesse (GRIG)
| | - Isabelle Villena
- Université Reims Champagne -Ardenne, EA7510 et Centre National de Référence de la Toxoplasmose, Centre de Ressources Biologiques Toxoplasma, Service de Parasitologie-Mycologie, Centre Hospitalier Universitaire de Reims, Reims, France
| |
Collapse
|
9
|
Lazzarotto T, Blázquez-Gamero D, Delforge ML, Foulon I, Luck S, Modrow S, Leruez-Ville M. Congenital Cytomegalovirus Infection: A Narrative Review of the Issues in Screening and Management From a Panel of European Experts. Front Pediatr 2020; 8:13. [PMID: 32083040 PMCID: PMC7006044 DOI: 10.3389/fped.2020.00013] [Citation(s) in RCA: 49] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/23/2019] [Accepted: 01/10/2020] [Indexed: 01/01/2023] Open
Abstract
Maternal primary and non-primary cytomegalovirus (CMV) infection during pregnancy can result in in utero transmission to the developing fetus. Congenital CMV (cCMV) can result in significant morbidity, mortality or long-term sequelae, including sensorineural hearing loss, the most common sequela. As a leading cause of congenital infections worldwide, cCMV infection meets many of the criteria for screening. However, currently there are no universal programs that offer maternal or neonatal screening to identify infected mothers and infants, no vaccines to prevent infection, and no efficacious and safe therapies available for the treatment of maternal or fetal CMV infection. Data has shown that there are several maternal and neonatal screening strategies, and diagnostic methodologies, that allow the identification of those at risk of developing sequelae and adequately detect cCMV. Nevertheless, many questions remain unanswered in this field. Well-designed clinical trials to address several facets of CMV treatment (in pregnant women, CMV-infected fetuses and both symptomatic and asymptomatic neonates and children) are required. Prevention (vaccines), biology and transmission factors associated with non-primary CMV, and the cost-effectiveness of universal screening, all demand further exploration to fully realize the ultimate goal of preventing cCMV. In the meantime, prevention of primary infection during pregnancy should be championed to all by means of hygiene education.
Collapse
Affiliation(s)
- Tiziana Lazzarotto
- Virology Lab, Polyclinic St. Orsola Malpighi, University of Bologna, Bologna, Italy
| | - Daniel Blázquez-Gamero
- Pediatric Infectious Diseases Unit, Hospital Universitario 12 de Octubre, Universidad Complutense, Instituto de Investigación Hospital 12 de Octubre (Imas12), Translational Research Network in Pediatric Infectious Diseases (RITIP), Madrid, Spain
| | | | - Ina Foulon
- Department of Otolaryngology - Head and Neck Surgery, Vrije Universiteit Brussel, Brussels, Belgium
| | - Suzanne Luck
- Kingston Hospital NHS Trust, Kingston upon Thames, United Kingdom.,Paediatric Infectious Diseases Research Group, St George's University of London, London, United Kingdom
| | - Susanne Modrow
- Institute of Medical Microbiology, University of Regensburg, Regensburg, Germany
| | | |
Collapse
|
10
|
Performance of Zika Assays in the Context of Toxoplasma gondii, Parvovirus B19, Rubella Virus, and Cytomegalovirus (TORCH) Diagnostic Assays. Clin Microbiol Rev 2019; 33:33/1/e00130-18. [PMID: 31826871 DOI: 10.1128/cmr.00130-18] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
Abstract
Infections during pregnancy that may cause congenital abnormalities have been recognized for decades, but their diagnosis is challenging. This was again illustrated with the emergence of Zika virus (ZIKV), highlighting the inherent difficulties in estimating the extent of pre- and postnatal ZIKV complications because of the difficulties in establishing definitive diagnoses. We reviewed the epidemiology, infection kinetics, and diagnostic methods used for Toxoplasma gondii, parvovirus B19, rubella virus, and cytomegalovirus (TORCH) infections and compared the results with current knowledge of ZIKV diagnostic assays to provide a basis for the inclusion of ZIKV in the TORCH complex evaluations. Similarities between TORCH pathogens and ZIKV support inclusion of ZIKV as an emerging TORCH infection. Our review evaluates the diagnostic performance of various TORCH diagnostic assays for maternal screening, fetal screening, and neonatal screening. We show that the sensitivity, specificity, and positive and negative predictive value of TORCH complex pathogens are widely variable, stressing the importance of confirmatory testing and the need for novel techniques for earlier and accurate diagnosis of maternal and congenital infections. In this context it is also important to acknowledge different needs and access to care for different geographic and resource settings.
Collapse
|
11
|
Douet T, Armengol C, Charpentier E, Chauvin P, Cassaing S, Iriart X, Berry A, Fillaux J. Performance of seven commercial automated assays for the detection of low levels of anti-Toxoplasma IgG in French immunocompromised patients. Parasite 2019; 26:51. [PMID: 31441775 PMCID: PMC6707100 DOI: 10.1051/parasite/2019052] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2019] [Accepted: 08/02/2019] [Indexed: 11/14/2022] Open
Abstract
BACKGROUND Immunocompromised patients are at high risk for the development of severe toxoplasmosis from tissue cyst reactivation, the most frequently, or from recently acquired acute infections. Knowledge of serologic status is therefore crucial. Screening for toxoplasmosis is sometimes performed while patients are already immunocompromised and have a low or even undetectable IgG titer by routine automated enzyme immunoassays. The aim of this study was to assess the sensitivity and specificity of seven reagents for the detection of low levels of IgG. Sera from 354 patients were collected and analysed. RESULTS Elecsys® offered the best analytic performances, superior to those of Architect® and Platelia®, which were superior to those of Access II® and TGS TA®. Vidas II® and Liaison II® reagents exhibited poor analytical performances in this cohort. For Elecsys®, Platelia® and Architect®, new thresholds for the grey zone and positive zone have been defined to improve the sensitivity of these reagents while maintaining excellent specificity. CONCLUSIONS Commercialized assays for toxoplasmosis screening are not suitable for IgG low-level detection in patients without adapting the supplier thresholds to avoid false negative results and risk generalized toxoplasmosis.
Collapse
Affiliation(s)
- Tiphaine Douet
-
Service de Parasitologie – Mycologie, Centre Hospitalier Universitaire de Toulouse-Purpan 330 avenue de Grande Bretagne 31059 Toulouse France
| | - Catherine Armengol
-
Service de Parasitologie – Mycologie, Centre Hospitalier Universitaire de Toulouse-Purpan 330 avenue de Grande Bretagne 31059 Toulouse France
-
Laboratoire d’analyse biomédicale, Centre Hospitalier Comminges Pyrénées Avenue de Saint Plancard 31806 Saint Gaudens France
| | - Elena Charpentier
-
Service de Parasitologie – Mycologie, Centre Hospitalier Universitaire de Toulouse-Purpan 330 avenue de Grande Bretagne 31059 Toulouse France
| | - Pamela Chauvin
-
Service de Parasitologie – Mycologie, Centre Hospitalier Universitaire de Toulouse-Purpan 330 avenue de Grande Bretagne 31059 Toulouse France
| | - Sophie Cassaing
-
Service de Parasitologie – Mycologie, Centre Hospitalier Universitaire de Toulouse-Purpan 330 avenue de Grande Bretagne 31059 Toulouse France
-
Pharmacochimie et Biologie Pour le Développement (PHARMA-DEV), IRD UMR 152 Université Paul Sabatier 35 Chemin des Maraîchers 31400 Toulouse France
| | - Xavier Iriart
-
Service de Parasitologie – Mycologie, Centre Hospitalier Universitaire de Toulouse-Purpan 330 avenue de Grande Bretagne 31059 Toulouse France
| | - Antoine Berry
-
Service de Parasitologie – Mycologie, Centre Hospitalier Universitaire de Toulouse-Purpan 330 avenue de Grande Bretagne 31059 Toulouse France
| | - Judith Fillaux
-
Service de Parasitologie – Mycologie, Centre Hospitalier Universitaire de Toulouse-Purpan 330 avenue de Grande Bretagne 31059 Toulouse France
-
Pharmacochimie et Biologie Pour le Développement (PHARMA-DEV), IRD UMR 152 Université Paul Sabatier 35 Chemin des Maraîchers 31400 Toulouse France
| |
Collapse
|
12
|
Evaluation of a New Immunochromatography Technology Test (LDBio Diagnostics) To Detect Toxoplasma IgG and IgM: Comparison with the Routine Architect Technique. J Clin Microbiol 2017; 55:3395-3404. [PMID: 28954897 DOI: 10.1128/jcm.01106-17] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2017] [Accepted: 09/08/2017] [Indexed: 11/20/2022] Open
Abstract
A study comparing the ICT (immunochromatography technology) Toxoplasma IgG and IgM rapid diagnostic test (LDBio Diagnostics, France) with a fully automated system, Architect, was performed on samples from university hospitals of Marseille and Saint-Etienne. A total of 767 prospective sera and 235 selected sera were collected. The panels were selected to test various IgG and IgM parameters. The reference technique, Toxoplasma IgGII Western blot analysis (LDBio Diagnostics), was used to confirm the IgG results, and commercial kits Platelia Toxo IgM (Bio-Rad) and Toxo-ISAgA (bioMérieux) were used in Saint-Etienne and Marseille, respectively, as the IgM reference techniques. Sensitivity and specificity of the ICT and the Architect IgG assays were compared using a prospective panel. Sensitivity was 100% for the ICT test and 92.1% for Architect (cutoff at 1.6 IU/ml). The low-IgG-titer serum results confirmed that ICT sensitivity was superior to that of Architect. Specificity was 98.7% (ICT) and 99.8% (Architect IgG). The ICT test is also useful for detecting IgM without IgG and is both sensitive (100%) and specific (100%), as it can distinguish nonspecific IgM from specific Toxoplasma IgM. In comparison, IgM sensitivity and specificity on Architect are 96.1% and 99.6%, respectively (cutoff at 0.5 arbitrary units [AU]/ml). To conclude, this new test overcomes the limitations of automated screening techniques, which are not sensitive enough for IgG and lack specificity for IgM (rare IgM false-positive cases).
Collapse
|
13
|
Zhang K, Lin G, Han Y, Li J. The standardization of 5 immunoassays for anti-Toxoplasma immunoglobulin G(IgG). Clin Chim Acta 2017; 472:20-25. [PMID: 28694124 DOI: 10.1016/j.cca.2017.07.007] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2016] [Revised: 05/12/2017] [Accepted: 07/06/2017] [Indexed: 11/28/2022]
Abstract
BACKGROUND Quantitative immunoassays to detect IgG antibodies are the most commonly used tests for diagnosing toxoplasmosis. We investigated the current state of standardization of quantitative immunoassays used to measure anti-Toxoplasma IgG levels. METHODS Four fully automated immunoassays (Architect i4000ISR, Immulite 2000 Xpi, Siemens; Liaison, DiaSorin; Cobas e601, Roche) and one manual immunoassay (ELISA classic Toxo IgG, Virion Serion) were performed on the following: individual patient serum samples, the WHO international standards, control samples, and calibrators provided by 5 immunoassay manufacturers. Statistical analysis was used to illustrate the results. RESULTS No perfect correlation (slope=1.0) was found between any 2 assays. Large differences in anti-Toxoplasma IgG titers were observed among the 5 immunoassays using serum samples from individual patients. Using IS 01/600 as a calibrator minimized the inter-assay variability of anti-Toxoplasma IgG values CONCLUSIONS: There is still significant effort needed towards standardization of anti-Toxoplasma IgG quantitative immunoassays.
Collapse
Affiliation(s)
- Kuo Zhang
- National Center for Clinical Laboratories, Beijing Hospital, National Center of Gerontology, Beijing, People's Republic of China
| | - Guigao Lin
- National Center for Clinical Laboratories, Beijing Hospital, National Center of Gerontology, Beijing, People's Republic of China
| | - Yanxi Han
- National Center for Clinical Laboratories, Beijing Hospital, National Center of Gerontology, Beijing, People's Republic of China
| | - Jinming Li
- National Center for Clinical Laboratories, Beijing Hospital, National Center of Gerontology, Beijing, People's Republic of China.
| |
Collapse
|
14
|
Evaluation of serological and molecular tests used to identify Toxoplasma gondii infection in pregnant women attended in a public health service in São Paulo state, Brazil. Diagn Microbiol Infect Dis 2017; 89:13-19. [PMID: 28689893 DOI: 10.1016/j.diagmicrobio.2017.06.004] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2016] [Revised: 06/07/2017] [Accepted: 06/09/2017] [Indexed: 11/23/2022]
Abstract
Toxoplasmosis during pregnancy can have severe consequences. The use of sensitive and specific serological and molecular methods is extremely important for the correct diagnosis of the disease. We compared the ELISA and ELFA serological methods, conventional PCR (cPCR), Nested PCR and quantitative PCR (qPCR) in the diagnosis of Toxoplasma gondii infection in pregnant women without clinical suspicion of toxoplasmosis (G1=94) and with clinical suspicion of toxoplasmosis (G2=53). The results were compared using the Kappa index, and the sensitivity, specificity, positive predictive value and negative predictive value were calculated. The results of the serological methods showed concordance between the ELISA and ELFA methods even though ELFA identified more positive cases than ELISA. Molecular methods were discrepant with cPCR using B22/23 primers having greater sensitivity and lower specificity compared to the other molecular methods.
Collapse
|
15
|
Armengol C, Cassaing S, Roques-Malecaze C, Chauvin P, Iriart X, Berry A, Fillaux J. Time before anti-Toxoplasma IgG seroconversion detection by 7 commercial assays in French pregnant women. Diagn Microbiol Infect Dis 2016; 87:103-107. [PMID: 27884549 DOI: 10.1016/j.diagmicrobio.2016.10.020] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2016] [Revised: 10/18/2016] [Accepted: 10/19/2016] [Indexed: 11/28/2022]
Abstract
We assessed the ability to early detect a toxoplasmic seroconversion between 1 immunoblot (LDBIO II®) and 6 automated assays (TGS TA®, Architect®, Vidas II®, Liaison II®, Platelia®, and Elecsys®), comparing the time before anti-Toxoplasma gondii IgG detection during infection in pregnant women. From 2007 to 2015, 620 sera of 269 women were included. The median durations before positive IgG detection with Vidas II®, Liaison II®, Platelia®, and Elecsys® were significantly longer than Architect® with differential times from 11 to 28days (P<0.001). This time was significantly shortened by the use of LDBIO®, resulting in a saving of 13days (P<0.001). The detection of a positive rate of IgG with TGS TA® was as early as Architect® (P=0.105). The ability to early detect a toxoplasmic seroconversion is not equivalent between the assays and has to be considered when selecting the reagents to reduce the time to therapeutic intervention.
Collapse
Affiliation(s)
- Catherine Armengol
- Service de Parasitologie-Mycologie, Hôpital Purpan, Toulouse, 31059, France
| | - Sophie Cassaing
- Service de Parasitologie-Mycologie, Hôpital Purpan, Toulouse, 31059, France; Pharmacochimie et Biologie Pour le Développement (PHARMA-DEV), IRD UMR 152 Université Paul Sabatier, Toulouse, 31400, France
| | | | - Pamela Chauvin
- Service de Parasitologie-Mycologie, Hôpital Purpan, Toulouse, 31059, France
| | - Xavier Iriart
- Service de Parasitologie-Mycologie, Hôpital Purpan, Toulouse, 31059, France
| | - Antoine Berry
- Service de Parasitologie-Mycologie, Hôpital Purpan, Toulouse, 31059, France
| | - Judith Fillaux
- Service de Parasitologie-Mycologie, Hôpital Purpan, Toulouse, 31059, France; Pharmacochimie et Biologie Pour le Développement (PHARMA-DEV), IRD UMR 152 Université Paul Sabatier, Toulouse, 31400, France.
| |
Collapse
|
16
|
Help in the Choice of Automated or Semiautomated Immunoassays for Serological Diagnosis of Toxoplasmosis: Evaluation of Nine Immunoassays by the French National Reference Center for Toxoplasmosis. J Clin Microbiol 2016; 54:3034-3042. [PMID: 27733631 DOI: 10.1128/jcm.01193-16] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2016] [Accepted: 09/28/2016] [Indexed: 11/20/2022] Open
Abstract
Toxoplasmosis, a benign infection, is asymptomatic or paucisymptomatic in over 80% of cases, except in immunocompetent patients suffering from ocular toxoplasmosis or in immunocompromised patients with opportunistic or congenital toxoplasmosis. Diagnosis is based mainly on serology testing. Thus, we compared the performance of the nine most commonly used commercial automated or semiautomated immunoassays for IgG and IgM Toxoplasma gondii antibody detection, that is, the Advia Centaur, Architect, AxSYM, Elecsys, Enzygnost, Liaison, Platelia, VIDAS, and VIDIA assays. The assays were conducted on four panels of serum samples derived during routine testing from patients with an interfering disease and who exhibited a low IgG antibody level in one of two clinical settings, namely, acute or chronic toxoplasmosis. As a result, IgG sensitivities ranged from 97.1% to 100%, and IgG specificities ranged from 99.5% to 100%. For IgG quantification, strong differences in IgG titers (expressed in IU/ml) were noted depending on the assay used. IgM sensitivities ranged from 65% to 97.9%, and IgM specificities ranged from 92.6% to 100%. For defining the best serological strategies to be implemented, it appears crucial to compare the diagnostic performance of the different tests with respect to their specificity and sensitivity in detecting the presence of IgG and IgM antibodies.
Collapse
|
17
|
Zhang K, Lin G, Han Y, Li J. Serological diagnosis of toxoplasmosis and standardization. Clin Chim Acta 2016; 461:83-9. [DOI: 10.1016/j.cca.2016.07.018] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2016] [Revised: 07/19/2016] [Accepted: 07/23/2016] [Indexed: 11/26/2022]
|
18
|
Performance of the BioPlex 2200 flow immunoassay in critical cases of serodiagnosis of toxoplasmosis. CLINICAL AND VACCINE IMMUNOLOGY : CVI 2014; 21:496-500. [PMID: 24477853 DOI: 10.1128/cvi.00624-13] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
The BioPlex 2200 automated analyzer (Bio-Rad Laboratories, Hercules, CA) is a recently developed multiplex analyzer that enables the detection of anti-Toxoplasma, -rubella, and -cytomegalovirus antibodies in the same assay. The aim of this study was to compare this new technology (using the BioPlex 2200 ToRC IgG/IgM kit) in critical cases of serodiagnosis of toxoplasmosis (acute, chronic, or congenital infections and cases with discrepant results) to the technologies used in our routine practice, i.e., the Platelia IgG/IgM enzyme-linked immunosorbent assays (ELISAs) (Bio-Rad Laboratories) and the Toxo-Screen direct agglutination assay (bioMérieux, Lyon, France). Overall, most cases of false-positive/negative results obtained with the Platelia IgG or Toxo-Screen assay were corrected by the BioPlex 2200 ToRC IgG (87.5%). Furthermore, the analysis of 35 sequences of sera showed a trend toward a more rapid decrease of IgM titers by BioPlex 2200 than by Platelia. These results for IgM detection can be explained by a weaker detection of residual IgM. Indeed, among 23 serum samples from patients with probable past infection with long-lasting IgM (Platelia M positive and IgG avidity index, ≥0.5), the BioPlex 2200 Toxoplasma IgM assay was positive for only 11 serum samples. In our panel of critical cases comprising 156 serum and 6 cord blood samples from 103 patients with acute, chronic, or congenital infection, the BioPlex 2200 IgG assay was a sensitive (97.8%) and specific (91.3%) method for IgG detection. The high specificity (97.4%) of IgM detection combined with the shorter kinetics of IgM titers may considerably reduce the number of residual IgM detections, thus yielding more precise diagnoses of acute infections.
Collapse
|
19
|
Murat JB, Fricker Hidalgo H, Brenier-Pinchart MP, Pelloux H. Human toxoplasmosis: which biological diagnostic tests are best suited to which clinical situations? Expert Rev Anti Infect Ther 2014; 11:943-56. [DOI: 10.1586/14787210.2013.825441] [Citation(s) in RCA: 42] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
20
|
Comparison of the Vidas system and two recent fully automated assays for diagnosis and follow-up of toxoplasmosis in pregnant women and newborns. CLINICAL AND VACCINE IMMUNOLOGY : CVI 2013; 20:1203-12. [PMID: 23740928 DOI: 10.1128/cvi.00089-13] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Serological testing to detect toxoplasmosis is of major importance to avoid the possible effects of the disease in newborns. This study assessed anti-Toxoplasma IgG and IgM with the Vidas (bioMérieux), Architect (Abbott), and Liaison (DiaSorin) systems in 631 sera from pregnant women and newborns as well as anti-Toxoplasma IgG avidity with these three systems on 54 sera from pregnant women with positive IgG and IgM. The IgG and IgM results were in agreement in, respectively, 95.2% and 98.3% (Vidas versus Architect) and 96.9% and 95.3% (Vidas versus Liaison) of the samples. Specificities were excellent for all the assays, while Vidas sensitivities ranged (depending on the classification of gray zone results) from 93.8 to 98.4% for IgG (Architect, 84.4 to 93.8%; Liaison, 93.8%) and from 81.8 to 90.9% for IgM (Architect, 63.6%; Liaison, 81.8 to 90.9%). In seroconversion sequences, IgMs were generally detected simultaneously by the three assays, while Architect was the earliest assay to detect IgG. In noninfected children, maternally transmitted IgGs were detected for a longer time with Architect than with the other systems. IgMs were positive in only one infected child with the Vidas and Liaison systems. Significantly more sera were classified in the high-avidity category with Vidas than with Architect. This evaluation shows similar performances for Vidas and more recent systems. The Vidas system adequately detects toxoplasmosis in pregnant women and newborns. This system fits the needs of laboratories working on small routine series for first-line testing as well as expert laboratories, due to a high specificity and a powerful avidity test.
Collapse
|
21
|
Toxoplasma seroconversion with negative or transient immunoglobulin M in pregnant women: myth or reality? A French multicenter retrospective study. J Clin Microbiol 2013; 51:2103-11. [PMID: 23616461 DOI: 10.1128/jcm.00169-13] [Citation(s) in RCA: 45] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
Classically, Toxoplasma infection is associated with high levels of specific IgM antibody and a rise in specific IgG levels 1 to 3 weeks later. Atypical IgG seroconversion, without IgM detection or with transient IgM levels, has been described during serologic follow-up of seronegative pregnant women and raises difficulties in interpreting the results. To evaluate the frequency and the characteristics of these atypical cases of seroconversion, an investigation was conducted within the French National Reference Center for Toxoplasmosis, from which 26 cases collected from 12 laboratories belonging to the network were identified. The aim of this work was to retrospectively analyze the results of serologic testing, the treatments administered, and the results of prenatal and postnatal follow-up for these women. In each case, IgG antibodies were detected using both screening and confirmatory tests. IgM antibodies were not detected in 15 cases, and the levels were equivocal or low-positive in 11 cases. The IgG avidity results were low in 16 cases and high in one case. Most of the pregnant women (22/26) were treated with spiramycin from the time that IgG antibodies appeared until delivery. Amniotic fluid was analyzed for Toxoplasma gondii DNA by PCR in 11/26 cases, and the results were negative in all cases. Congenital toxoplasmosis was ruled out in 12/26 newborns. There was no abnormality observed at birth for 10 newborns and no information available for 4 newborns. In conclusion, when the interpretation of serological results is so difficult, it seems cautious to initiate treatment by spiramycin and to follow the pregnant women and their newborns.
Collapse
|
22
|
Performance characteristics of current-generation Immulite 2000 TORCH Assays. CLINICAL AND VACCINE IMMUNOLOGY : CVI 2012; 20:122-6. [PMID: 23175287 DOI: 10.1128/cvi.00106-12] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
The performances of seven Immulite 2000 (Siemens Healthcare Diagnostics) TORCH (Toxoplasma gondii, other microorganisms, rubella virus, cytomegalovirus, and herpes simplex virus) assays were evaluated in comparison with the performances of the ETI-MAX 3000 (DiaSorin) TORCH assays. The two systems demonstrated good agreement, and given their sensitivity, specificity, and positive predictive value, they can be used with confidence for TORCH prenatal screening.
Collapse
|
23
|
Souza GFD, Carvalho D, Pedrosa W, Franck J, Piarroux R. Analytical validation of anti-toxoplasma IgG immunoassays. Braz J Infect Dis 2012; 16:574-6. [DOI: 10.1016/j.bjid.2012.07.014] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2012] [Accepted: 07/11/2012] [Indexed: 11/24/2022] Open
|
24
|
Evaluation of the new Elecsys Toxo IgG avidity assay for toxoplasmosis and new insights into the interpretation of avidity results. CLINICAL AND VACCINE IMMUNOLOGY : CVI 2012; 19:1838-43. [PMID: 22993406 DOI: 10.1128/cvi.00333-12] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Detection and treatment of acute toxoplasmosis during pregnancy can avoid severe disease of the fetus. In this context, assessment of anti-Toxoplasma IgG avidity has been shown to exclude recent infection. The Elecsys Toxo IgG and IgM assays (Roche Diagnostics) have been validated for screening pregnant women and a new assay, Elecsys Toxo IgG Avidity, was recently developed. Our aims were to investigate the performance characteristics of this new avidity assay and explore whether additional information can be provided by avidity assays. The Elecsys assay was compared with the Vidas (bioMérieux) and Architect (Abbott) Avidity assays using two sets of serum samples (n = 291 and n = 255). The rate of general agreement between the Elecsys and Vidas assays was 74%, and that between the Elecsys and Architect assays was 83%. For 11% of the serum samples, avidity was high with the Vidas assay and within the gray zone with the Elecsys assay. None of the assays detected high-avidity antibodies in serum taken <4 months after infection. Avidity values of >90% were exclusively reported in sera taken >9 months after infection by the Elecsys and Architect assays. Almost all avidities of <19% with the Elecsys assay and <17% with the Architect assay corresponded to sera taken <3 and <2 months after infection, respectively. The Elecsys IgG Avidity assay can be used to exclude recent infection. New ways of interpreting the avidity result are also suggested: very high or low values could exclude infections within the last 9 months or help to confirm a recent infection, respectively. However, these potential interpretations require further investigation.
Collapse
|
25
|
Abstract
Toxoplasmosis is a worldwide infection caused by the intracellular parasite Toxoplasma gondii. At least a third of the world human population are infected with the parasite, making it one of the most successful parasitic infections. Primary maternal infection may cause health-threatening sequelae for the foetus, or even cause death in uterus. Reactivation of a latent infection in immune deficiency conditions such as AIDS and organ transplantation can cause fatal toxoplasmic encephalitis. Toxoplasmosis is a major cause of retinochoroiditis, especially in individuals with an impaired immune system. Despite the usually 'asymptomatic' nature of the infection, a significant burden imposed by the parasite necessitates the implementation of effective means for the prevention, diagnosis, and management of this disease. Laboratory diagnosis, i.e. PCR and serologic assays, plays the main role in the diagnosis of congenital infection and assists in the confirmatory diagnosis of toxoplasmic encephalitis and ocular toxoplasmosis. Here, we briefly review general aspects of Toxoplasma infection and focus on the diagnostic methods currently used in medical laboratories for the diagnosis of Toxoplasma infection.
Collapse
Affiliation(s)
- Geita Saadatnia
- Molecular Parasitology Laboratory, Parasitology Department, Pasteur Institute of Iran, Tehran, Iran
| | | |
Collapse
|
26
|
di Carlo P, Romano A, Casuccio A, Cillino S, Schimmenti MG, Mancuso G, la Chiusa S, Novara V, Ingrassia D, li Vecchi V, Trizzino M, Titone L. Investigation and management of Toxoplasma gondii infection in pregnancy and infancy: a prospective study. Acta Pharmacol Sin 2011; 32:1063-70. [PMID: 21743484 DOI: 10.1038/aps.2011.55] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022] Open
Abstract
AIM Toxoplasma gondii infection during pregnancy poses a serious risk to the fetus, therefore timely and accurate diagnosis is essential. The aim of this study was to estimate the frequency of congenital infection via evaluating mother's immunological status and the possibility to improving the diagnostic and therapeutic approaches. METHODS Eighty five mothers with Toxoplasma seroconversion and their offspring were enrolled (among them, 2 spontaneous abortions were documented in the first trimester). Prenatal PCR diagnosis was carried out on 50 patients (60%), with 7 positive cases (14%). Morphological ultrasound scanning revealed anomalies in one fetus. Long-term follow-up included general physical examinations, serological status tested using Western blot, neuro-radiological, ophthalmologic and neurologic examinations, psychological and developmental tests, visual evoked potential tests and audiology tests, as well as anti-Toxoplasma treatment regimes. RESULTS Fourteen (17%) of the infants were infected at one-year serological follow-up. Chi-square for linear trend of vertical transmission from the first to the third trimester was significant (P=0.009). Western blot analysis showed IgM and IgA in half of the infected infants. In 69 uninfected infants, anti-Toxoplasma IgG immunoblot analysis excluded infection within the 3 months in 18 infants (26%) and in the others within 6 months of life. The most relevant instrumental findings are described. CONCLUSION Western blot analysis may help to evaluate infection within the 6 months of life. The accuracy of ultrasound imaging to determine the brain damage in the fetus and newborns is doubtful, and should be combined with MR imaging. Multistep approaches can improve the timing of postnatal follow-up.
Collapse
|
27
|
Identification of Toxoplasma gondii SUB1 antigen as a marker for acute infection by use of an innovative evaluation method. J Clin Microbiol 2011; 49:2419-25. [PMID: 21543561 DOI: 10.1128/jcm.00464-11] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
By the separation of Toxoplasma lysate using two-dimensional gel electrophoresis and its analysis with human serum samples and mass spectrometry, the subtilisin-like protein (SUB1) was identified to be a potential marker for acute toxoplasmosis. Following expression of the C-terminal domain of SUB1 in Escherichia coli, it was tested in a line blot assay using a total of 80 human serum samples. Two computer programs based on different evaluation strategies were used for judgment of the line blot results: (i) a time-dependent method with a predefined cutoff value and (ii) a fixed-time-point method with a calculated cutoff. Thereby, SUB1 was proven to be rather reactive with specific immunoglobulin A (IgA), IgM, and IgG of patients with an acute infection. This finding makes this antigen an attractive candidate for improving diagnosis of toxoplasmosis and demonstrates that not only the selection of respective antigens but also the evaluation method chosen are important for the evaluation of new diagnostic markers.
Collapse
|