1
|
Costa SP, Carvalho CM. Burden of bacterial bloodstream infections and recent advances for diagnosis. Pathog Dis 2022; 80:6631550. [PMID: 35790126 DOI: 10.1093/femspd/ftac027] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2022] [Revised: 06/07/2022] [Accepted: 07/01/2022] [Indexed: 11/13/2022] Open
Abstract
Bloodstream infections (BSIs) and subsequent organ dysfunction (sepsis and septic shock) are conditions that rank among the top reasons for human mortality and have a great impact on healthcare systems. Their treatment mainly relies on the administration of broad-spectrum antimicrobials since the standard blood culture-based diagnostic methods remain time-consuming for the pathogen's identification. Consequently, the routine use of these antibiotics may lead to downstream antimicrobial resistance and failure in treatment outcomes. Recently, significant advances have been made in improving several methodologies for the identification of pathogens directly in whole blood especially regarding specificity and time to detection. Nevertheless, for the widespread implementation of these novel methods in healthcare facilities, further improvements are still needed concerning the sensitivity and cost-effectiveness to allow a faster and more appropriate antimicrobial therapy. This review is focused on the problem of BSIs and sepsis addressing several aspects like their origin, challenges, and causative agents. Also, it highlights current and emerging diagnostics technologies, discussing their strengths and weaknesses.
Collapse
Affiliation(s)
- Susana P Costa
- Centre of Biological Engineering, University of Minho, Campus de Gualtar, 4710-057, Braga, Portugal.,LABBELS - Associate Laboratory, Braga/Guimarães, Portugal.,International Iberian Nanotechnology Laboratory, Av. Mestre José Veiga s/n, 4715-330, Braga, Portugal.,Instituto de Engenharia de Sistemas e Computadores - Microsistemas e Nanotecnologias (INESC MN) and IN - Institute of Nanoscience and Nanotechnology, Rua Alves Redol, 9 1000-029 Lisbon, Portugal
| | - Carla M Carvalho
- International Iberian Nanotechnology Laboratory, Av. Mestre José Veiga s/n, 4715-330, Braga, Portugal
| |
Collapse
|
2
|
Wang H, Salamon D, Jean S, Leber AL. Evaluation of the Cepheid Xpert SA Nasal Complete for direct detection of Staphylococcus aureus and methicillin-resistant Staphylococcus aureus in nasal swabs from pediatric patients. Diagn Microbiol Infect Dis 2021; 101:115417. [PMID: 34116341 DOI: 10.1016/j.diagmicrobio.2021.115417] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2021] [Revised: 04/22/2021] [Accepted: 04/23/2021] [Indexed: 11/27/2022]
Abstract
Nasal carriers of Staphylococcus aureus (SA) are at increased risk for health-care associated infections with this organism. Timely detection of SA and Methicillin-resistant SA (MRSA) and subsequent decolonization are important components of infection control. While performance of nucleic acid amplification-based tests for detection of SA/MRSA in adults has been well-described, limited data are available in children. Our objective was to evaluate the performance of the Xpert SA in pediatric patients. Overall, for detection of SA, Xpert SA demonstrated a sensitivity and specificity of 95.1% and 93.5%, respectively and 87.8% sensitive and 98.1% specific for detection of MRSA. Performance in different age groups was similar but neonates had the lowest sensitivity and highest invalid rates. The Xpert SA is a rapid, reliable test to detect MSSA and MRSA nasal colonization in pediatric patients. Depending on the potential clinical impact, culture may be considered as a companion test to improve sensitivity.
Collapse
Affiliation(s)
- Huanyu Wang
- Department of Pathology and Laboratory Medicine, Nationwide Children's Hospital; Department of Pathology, The Ohio State University, Columbus, OH
| | - Doug Salamon
- Department of Pathology and Laboratory Medicine, Nationwide Children's Hospital
| | - Sophonie Jean
- Department of Pathology and Laboratory Medicine, Nationwide Children's Hospital; Department of Pathology, The Ohio State University, Columbus, OH
| | - Amy L Leber
- Department of Pathology and Laboratory Medicine, Nationwide Children's Hospital; Department of Pathology, The Ohio State University, Columbus, OH; Department of Pediatrics, The Ohio State University, Columbus, OH.
| |
Collapse
|
3
|
Shrestha NK, Fraser TG, Gordon SM. Methicillin resistance in Staphylococcus aureus infections among patients colonized with methicillin-susceptible Staphylococcus aureus. Clin Microbiol Infect 2018; 25:71-75. [PMID: 29649598 DOI: 10.1016/j.cmi.2018.03.045] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2017] [Revised: 03/13/2018] [Accepted: 03/31/2018] [Indexed: 11/29/2022]
Abstract
OBJECTIVES We have noticed that patients colonized with methicillin-susceptible Staphylococcus aureus (MSSA) rarely get methicillin-resistant S. aureus (MRSA) infections. The purpose of this study was to compare the odds of a Staphylococcus aureus (SA) infection being an MRSA infection in MSSA carriers, MRSA carriers and non-carriers of SA. METHODS Hospitalizations of adult patients at the Cleveland Clinic Health System from 2008 to 2015 were screened to identify those where the patient was tested for SA colonization. The first such hospitalization was identified. Among these 90 891 patients, those who had an SA infection during the hospitalization were included. SA carrier status (MRSA, MSSA, or non-carrier), was defined based on the first nasal SA test result. The association of carrier status and MRSA infection was examined. RESULTS The mean (±standard deviation (SD)) age of the 1999 included patients was 61 (17) years, and 1160 (58%) were male. Thirty percent, 26%, and 44%, were MRSA carriers, MSSA carriers and non-carriers, respectively. Of the 601 SA infections in MRSA carriers (reference group), 552 (92%) were MRSA infections compared with 42 (8%) of 516 in MSSA carriers (odds ratio (OR) 0.008, 95% confidence interval (CI) 0.005-0.012, p <0.0001) and 430 (49%) of 882 in non-carriers (OR 0.072, 95% CI 0.051-0.100, p <0.0001), after controlling for age, sex, hospital length of stay and calendar year. CONCLUSION Among patients with SA infection, the odds of the infection being an MRSA infection are 125-times lower in an MSSA carrier than in an MRSA carrier.
Collapse
Affiliation(s)
- N K Shrestha
- Department of Infectious Diseases, Cleveland Clinic, Cleveland, OH, USA.
| | - T G Fraser
- Department of Infectious Diseases, Cleveland Clinic, Cleveland, OH, USA
| | - S M Gordon
- Department of Infectious Diseases, Cleveland Clinic, Cleveland, OH, USA
| |
Collapse
|
4
|
Tunsjø HS, Kalyanasundaram S, Worren MM, Leegaard TM, Moen AEF. High frequency of occupied attB regions in Norwegian Staphylococcus aureus isolates supports a two-step MRSA screening algorithm. Eur J Clin Microbiol Infect Dis 2016; 36:65-74. [PMID: 27638009 DOI: 10.1007/s10096-016-2771-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2016] [Accepted: 08/25/2016] [Indexed: 01/10/2023]
Abstract
Rapid nucleic acid amplification tests for methicillin-resistant Staphylococcus aureus (MRSA) diagnostics commonly target the mec resistance gene, genes specific for S. aureus, and the integration site for the SCCmec resistance cassette, orfX. Due to poor specificity when these target genes are used individually, additional culture is required to verify positive results. The combination of these targets is useful, but the optimal algorithm may depend on the presence of the genetic markers in S. aureus isolates, as well as the prevalence of MRSA in a population. The aim of the present study was to identify a rapid, low-cost, and functional screening algorithm in order to reduce the response time for MRSA diagnostics. An in-house orfX-SCCmec polymerase chain reaction (PCR) assay was established and evaluated. The results were compared with an existing mec/nuc PCR assay and traditional culture. Methicillin-sensitive S. aureus (MSSA) that tested false-positive in the orfX-SCCmec PCR assay were further investigated with full genome sequencing using the Ion PGM™ System to verify results and causality. Based on these data, a two-step screening algorithm with initial mec/nuc PCR followed by orfX-SCCmec PCR on positive samples was suggested and tested on 1443 patient samples. 22.5 % of MSSA isolates tested false-positive with the orfX-SCCmec PCR. Full genome sequencing of these isolates identified genetic variation in the attB region of S. aureus, including empty cassette variants and non-mec SCC. The suggested two-step MRSA screening algorithm allowed us to report MRSA results for 95.6 % of all samples and 99 % of MRSA-negative samples after one day.
Collapse
Affiliation(s)
- H S Tunsjø
- Department of Health Sciences, Oslo and Akershus University College, Oslo, Norway. .,Department of Microbiology and Infection Control, Akershus University Hospital, Lørenskog, Norway.
| | - S Kalyanasundaram
- Bioinformatics Core Facility, Department of Core Facilities, Institute of Cancer Research, Radium Hospital, part of Oslo University Hospital, Oslo, Norway
| | - M M Worren
- Institute for Cancer Genetics and Informatics, Radium Hospital, part of Oslo University Hospital, Oslo, Norway
| | - T M Leegaard
- Department of Microbiology and Infection Control, Akershus University Hospital, Lørenskog, Norway.,Institute of Clinical Medicine, University of Oslo, Oslo, Norway
| | - A E F Moen
- Institute of Clinical Medicine, University of Oslo, Oslo, Norway.,Department of Clinical Molecular Biology and Laboratory Sciences (EpiGen), Akershus University Hospital, Lørenskog, Norway
| |
Collapse
|
5
|
Performance of BD Max StaphSR for Screening of Methicillin-Resistant Staphylococcus aureus Isolates among a Contemporary and Diverse Collection from 146 Institutions Located in Nine U.S. Census Regions: Prevalence of mecA Dropout Mutants. J Clin Microbiol 2015; 54:204-7. [PMID: 26537444 DOI: 10.1128/jcm.02047-15] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2015] [Accepted: 10/27/2015] [Indexed: 01/01/2023] Open
Abstract
This study determined the performance of BD Max StaphSR and the rate of methicillin-resistant Staphylococcus aureus (MRSA) with an unrecognized staphylococcal cassette chromosome mec (SCCmec) right-extremity junction (MREJ) region among 907 methicillin-resistant S. aureus (MRSA) and 900 methicillin-susceptible S. aureus (MSSA) isolates. The rate of mecA/mecC dropout mutants was also evaluated. Only three MRSA isolates (99.7% sensitivity; 904/907) were classified as MSSA by the BD Max StaphSR assay, due to negative results for MREJ. Eight MSSA isolates (99.1% sensitivity; 892/900) were assigned as MRSA. However, six of these MSSA isolates had the mecA gene confirmed by PCR and sequencing (99.8% sensitivity; 898/900). Overall, 7.1% (64/900) of MSSA isolates showed results compatible with a mecA dropout genotype.
Collapse
|
6
|
Mehta MS, McClure J, Mangold K, Peterson LR. Performance of 3 real-time PCR assays for direct detection of Staphylococcus aureus and MRSA from clinical samples. Diagn Microbiol Infect Dis 2015; 83:211-5. [DOI: 10.1016/j.diagmicrobio.2014.06.005] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2013] [Revised: 05/18/2014] [Accepted: 06/10/2014] [Indexed: 11/16/2022]
|
7
|
Hirvonen JJ. The use of molecular methods for the detection and identification of methicillin-resistant Staphylococcus aureus. Biomark Med 2015; 8:1115-25. [PMID: 25402581 DOI: 10.2217/bmm.14.60] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
Methicillin-resistant Staphylococcus aureus (MRSA) is a major pathogen in many hospitals and long-term care facilities as well as in the community. To limit the spread of MRSA, early detection and proper treatment are essential. Because conventional culture as gold standard is time consuming, new techniques such as PCR-based and hybridization assays have emerged for the rapid detection of MRSA. This review will focus on the currently available molecular-based assays and on their utility and performance for detection of S. aureus, of its virulence factors and of the markers for acquired resistance.
Collapse
|
8
|
Seki M, Takahashi H, Yamamoto N, Hamaguchi S, Ojima M, Hirose T, Yoshiya K, Ogura H, Shimazu T, Tomono K. Polymerase chain reaction-based active surveillance of MRSA in emergency department patients. Infect Drug Resist 2015; 8:113-8. [PMID: 25999747 PMCID: PMC4437520 DOI: 10.2147/idr.s80123] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Conventional culture methods to detect methicillin-resistant Staphylococcus aureus (MRSA) take a few days, and their sensitivity and usefulness also need to be improved. In this study, active screening was performed using the polymerase chain reaction (PCR) for colonization with MRSA on admission and follow-up surveillance after admission to an emergency department between June 2012 and August 2012, and the backgrounds of PCR and/or culture-method-positive patients were compared. Among 95 patients, 15 (15.8%) patients were positive for MRSA on PCR and/or culture; 6.3% (6/95) of patients were positive on admission, and 9.5% (9/95) became positive during the stay after admission. The major primary diagnoses in MRSA-positive patients were trauma and cerebrovascular diseases. Nine (60%) of 15 patients were MRSA-positive on both PCR and culture, compared with three (20%) of 15 who were PCR-positive but culture-negative. The other three (20%) of 15 patients were PCR-negative but culture-positive. Furthermore, there was a tendency for younger age and shorter stay to be associated with PCR-positive but culture-negative results. These findings suggest that active surveillance with PCR may be highly sensitive and useful for the early diagnosis of MRSA colonization to prevent nosocomial transmission from the emergency department to the regular inpatient wards of the hospital.
Collapse
Affiliation(s)
- Masafumi Seki
- Division of Infection Control and Prevention, Osaka University Hospital, Suita, Osaka, Japan ; Division of Infection Control and Prevention, Tohoku Pharmaceutical University Hospital, Sendai, Japan
| | - Hiroki Takahashi
- Department of Traumatology and Acute Critical Medicine, Osaka University Hospital, Suita, Osaka, Japan
| | - Norihisa Yamamoto
- Division of Infection Control and Prevention, Osaka University Hospital, Suita, Osaka, Japan
| | - Shigeto Hamaguchi
- Division of Infection Control and Prevention, Osaka University Hospital, Suita, Osaka, Japan
| | - Masahiro Ojima
- Department of Traumatology and Acute Critical Medicine, Osaka University Hospital, Suita, Osaka, Japan
| | - Tomoya Hirose
- Department of Traumatology and Acute Critical Medicine, Osaka University Hospital, Suita, Osaka, Japan
| | - Kazuhisa Yoshiya
- Department of Traumatology and Acute Critical Medicine, Osaka University Hospital, Suita, Osaka, Japan
| | - Hiroshi Ogura
- Department of Traumatology and Acute Critical Medicine, Osaka University Hospital, Suita, Osaka, Japan
| | - Takeshi Shimazu
- Department of Traumatology and Acute Critical Medicine, Osaka University Hospital, Suita, Osaka, Japan
| | - Kazunori Tomono
- Division of Infection Control and Prevention, Osaka University Hospital, Suita, Osaka, Japan
| |
Collapse
|
9
|
Farley JE, Hayat MJ, Sacamano PL, Ross T, Carroll K. Prevalence and risk factors for methicillin-resistant Staphylococcus aureus in an HIV-positive cohort. Am J Infect Control 2015; 43:329-35. [PMID: 25687358 DOI: 10.1016/j.ajic.2014.12.024] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2014] [Revised: 12/22/2014] [Accepted: 12/23/2014] [Indexed: 01/31/2023]
Abstract
BACKGROUND Persons living with HIV (PLWH) are disproportionately burdened with methicillin-resistant Staphylococcus aureus (MRSA). Our objective was to evaluate prevalence and risks for MRSA colonization in PLWH. METHODS Adults were recruited from Johns Hopkins University AIDS Service in Baltimore, Maryland. A risk questionnaire and specimen collection from anatomic sites with culture susceptibility and genotyping were completed. Generalized estimating equation modeling identified MRSA colonization risk factors. RESULTS Of 500 participants, most were black (69%), on antiretroviral therapy (ART) (87%), with undetectable viral loads (73.4%). Median CD4 count was 487 cells/mm(3) (interquartile range, 316-676.5 cells/mm(3)). MRSA prevalence was 15.4%, predominantly from the nares (59.7%). Forty percent were nares negative but were colonized elsewhere. Lower odds for colonization were associated with recent sexual activity (adjusted odds ratio [AOR] = 0.84, P < .001) and ART (AOR = 0.85, P = .011). Increased odds were associated with lower income (<$25,000 vs >$75,000; AOR = 2.68, P < .001), recent hospitalization (AOR = 1.54, P < .001), incarceration (AOR = 1.55, P < .001), use of street drugs (AOR = 1.43, P < .001), and skin abscess (AOR = 1.19, P < .001). CONCLUSIONS Even with high MRSA prevalence, the proportion identified through nares surveillance alone was low, indicating the importance of screening multiple anatomic sites. Associations were not found with same-sex coupling or black race. MRSA prevention might be a benefit of ART in PLWH.
Collapse
|
10
|
Bandara AB, Zuo Z, Ramachandran S, Ritter A, Heflin JR, Inzana TJ. Detection of methicillin-resistant staphylococci by biosensor assay consisting of nanoscale films on optical fiber long-period gratings. Biosens Bioelectron 2015; 70:433-40. [PMID: 25845336 DOI: 10.1016/j.bios.2015.03.041] [Citation(s) in RCA: 42] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2015] [Accepted: 03/17/2015] [Indexed: 11/29/2022]
Abstract
Methicillin-resistance among Staphylococcus species is a major health problem in hospitals, communities, and animals. There is a need for culture-free diagnostic assays that can be carried out rapidly, and maintain a high degree of sensitivity and specificity. To address this need an ionic self-assembled multilayer (ISAM) film was deposited on the surface of a long-period grating (LPG) optical fiber by immersion alternately in poly-allylamine hydrochloride and in poly-1-[p-(3'-carboxy-4'-hydroxyphenylazo) benzenesulfonamido]-1,2-ethandiyl (PCBS), resulting in terminal carboxyl groups on the LPG-ISAM. The terminal carboxyl groups were covalently conjugated to monoclonal antibodies (MAb) specific to penicillin-binding-protein 2a of methicillin resistant (MR) staphylococci. After exposure of the LPG-ISAM to 10(2) colony forming units (CFU)/ml of MR S. aureus (MRSA) for 50 min., light transmission was reduced by 19.7%. In contrast, after exposure to 10(6) CFU/ml of methicillin-sensitive S. aureus (MSSA) attenuation of light transmission was less than 1.8%. Exposure of the LPG-ISAM to extracts of liver, lungs, or spleen from mice infected with MRSA attenuated light transmission by 11.7-73.5%. In contrast, exposure of the biosensor to extracts from MSSA-infected mice resulted in 5.6% or less attenuation of light transmission. When the sensor was tested with 36 strains of MR staphylococci, 15 strains of methicillin-sensitive staphylococci, 10 strains of heterologous genera (all at 10(4) CFU/ml), or tissue samples from mice infected with MRSA, there was complete agreement between MR and non-MR bacteria determined by antibiotic susceptibility testing and the biosensor assay when the cutoff value for attenuation of light transmission was 6.3%. Thus, the biosensor described has the potential to detect MR staphylococci in clinical samples with a high degree of sensitivity and specificity.
Collapse
Affiliation(s)
- Aloka B Bandara
- Department of Biomedical Sciences and Pathobiology, Life Sciences 1, 970 Washington Street, SW, Virginia Tech, Blacksburg, VA 24061, USA.
| | - Ziwei Zuo
- Department of Physics, 850 West Campus Drive, Virginia Tech, Blacksburg, VA 24061, USA.
| | - Siddharth Ramachandran
- Department of Electrical and Computer Engineering, 8 Saint Mary's Street, Boston University, Boston, MA 02215, USA.
| | - Alfred Ritter
- Virginia nanoTech, LLC, 2200 Kraft Drive, Blacksburg, VA 24060, USA.
| | - James R Heflin
- Department of Physics, 850 West Campus Drive, Virginia Tech, Blacksburg, VA 24061, USA; Virginia nanoTech, LLC, 2200 Kraft Drive, Blacksburg, VA 24060, USA.
| | - Thomas J Inzana
- Department of Biomedical Sciences and Pathobiology, Life Sciences 1, 970 Washington Street, SW, Virginia Tech, Blacksburg, VA 24061, USA; Virginia Tech Carilion School of Medicine, 2 Riverside Circle, Roanoke, VA 24016, USA.
| |
Collapse
|
11
|
Sarda V, Molloy A, Kadkol S, Janda WM, Hershow R, McGuinn M. Active Surveillance for Methicillin-Resistant Staphylococcus aureus in the Neonatal Intensive Care Unit. Infect Control Hosp Epidemiol 2015; 30:854-60. [DOI: 10.1086/605321] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Background.We describe our experience using a real-time polymerase chain reaction (PCR) assay for methicillin-resistant Staphylococcus aureus (MRSA) during a period of active surveillance in the neonatal intensive care unit (NICU) from March 2007 until November 2007.Objective.TO compare PCR with bacterial culture methods and find the screening algorithm that most successfully ensures appropriate isolation of colonized patients.Methods.Patients in the NICU were screened for MRSA on admission and weekly thereafter until discharge. Healthcare workers (HCWs) were also screened as part of an outbreak investigation. A total of 599 individuals were screened for MRSA with both a PCR assay and selective bacterial culture. Strain typing was performed on all MRSA isolates to determine clonal relatedness.Results.Twenty-one of 435 infants (4.8%) screened positive for MRSA with the PCR assay. Only 11 patients (52.4%) had concomitant bacterial cultures positive for MRSA. Compared to bacterial culture, the PCR assay had a sensitivity of 100% and a specificity of 97.6%, with a positive predictive value (PPV) of 52.4%. Infants that tested positive for MRSA by both culture and PCR were more likely to have a positive PCR assay result when retested than were those who tested positive by PCR alone (80% vs 20%; P = .02). Strain typing of MRSA isolates identified a common clone in only 2 colonized infants.Conclusion.Our data show that, in our neonatal population, the reproducibility of PCR assay results for culture-negative patients was low compared with the reproducibility of results for culture-positive Patients. Furthermore, the low PPV suggests that for nearly half of individuals who were PCR-positive, the result was falsely positive, which argues against the use of PCR assays alone for MRSA screening in the NICU.
Collapse
|
12
|
Abstract
A comparison between the BD MAX MRSA and Xpert MRSA assays was performed using 239 nares samples. A 97.9% overall agreement between the two molecular assays was observed. The BD MAX MRSA assay proved to be a reliable alternative for a highly automated system to detect methicillin-resistant Staphylococcus aureus (MRSA) in patient nares samples.
Collapse
|
13
|
Hirvonen JJ, Kaukoranta SS. GenomEra MRSA/SA, a fully automated homogeneous PCR assay for rapid detection ofStaphylococcus aureusand the marker of methicillin resistance in various sample matrixes. Expert Rev Mol Diagn 2014; 13:655-65. [DOI: 10.1586/14737159.2013.820542] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
14
|
Schinasi L, Wing S, MacDonald PDM, Richardson DB, Stewart JR, L Augustino K, Nobles DL, Ramsey KM. Medical and household characteristics associated with methicillin resistant Staphylococcus aureus nasal carriage among patients admitted to a rural tertiary care hospital. PLoS One 2013; 8:e73595. [PMID: 23991200 PMCID: PMC3753306 DOI: 10.1371/journal.pone.0073595] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2012] [Accepted: 07/26/2013] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Methicillin resistant Staphylococcus aureus (MRSA) poses a threat to patient safety and public health. Understanding how MRSA is acquired is important for prevention efforts. This study investigates risk factors for MRSA nasal carriage among patients at an eastern North Carolina hospital in 2011. METHODS Using a case-control design, hospitalized patients ages 18 - 65 years were enrolled between July 25, 2011 and December 15, 2011 at Vidant Medical Center, a tertiary care hospital that screens all admitted patients for nasal MRSA carriage. Cases, defined as MRSA nasal carriers, were age and gender matched to controls, non-MRSA carriers. In-hospital interviews were conducted, and medical records were reviewed to obtain information on medical and household exposures. Multivariable conditional logistic regression was used to derive odds ratio (OR) estimates of association between MRSA carriage and medical and household exposures. RESULTS In total, 117 cases and 119 controls were recruited to participate. Risk factors for MRSA carriage included having household members who took antibiotics or were hospitalized (OR: 3.27; 95% Confidence Interval (CI): 1.24-8.57) and prior hospitalization with a positive MRSA screen (OR: 3.21; 95% CI: 1.12-9.23). A lower proportion of cases than controls were previously hospitalized without a past positive MRSA screen (OR: 0.40; 95% CI: 0.19-0.87). CONCLUSION These findings suggest that household exposures are important determinants of MRSA nasal carriage in hospitalized patients screened at admission.
Collapse
Affiliation(s)
- Leah Schinasi
- Department of Epidemiology, The University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA.
| | | | | | | | | | | | | | | |
Collapse
|
15
|
Analysis of Staphylococcal cassette chromosome mec in BD GeneOhm MRSA assay-negative strains. Antimicrob Agents Chemother 2013; 57:2890-1. [PMID: 23571551 DOI: 10.1128/aac.00174-13] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
The BD GeneOhm MRSA assay could identify methicillin-resistant Staphylococcus aureus (MRSA) strains at a high ratio (97.8%). Analysis of 11 assay-negative MRSA strains suggested that insertion of non-mec staphylococcal cassette chromosome elements (SCCs) downstream of orfX, and carriage of SCCmecs with a left extremity that cannot be detected by the kit, might lead to their being given an incorrect negative status.
Collapse
|
16
|
Li J, Ulvin K, Biboh H, Kristiansen I. Cost–effectiveness of supplementing a broth-enriched culture test with the Xpert meticillin-resistant Staphylococcus aureus (MRSA) assay for screening inpatients at high risk of MRSA. J Hosp Infect 2012; 82:227-33. [DOI: 10.1016/j.jhin.2012.08.009] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2012] [Accepted: 08/22/2012] [Indexed: 11/30/2022]
|
17
|
Three-way comparison of BBL CHROMagar MRSA II, MRSASelect, and spectra MRSA for detection of methicillin-resistant Staphylococcus aureus isolates in nasal surveillance cultures. J Clin Microbiol 2012; 51:202-5. [PMID: 23135930 DOI: 10.1128/jcm.02022-12] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022] Open
Abstract
Methicillin-resistant Staphylococcus aureus (MRSA) is a major cause of hospital-acquired and life-threatening infections. Active surveillance programs for MRSA utilize either molecular or culture-based methods. A prospective study was performed to compare the performance of selective and differential chromogenic media, BBL CHROMagar MRSA II (CMRSA II; BD Diagnostics, Sparks, MD), MRSASelect (Bio-Rad Laboratories, Redmond, WA), and Spectra MRSA (Remel, Lenexa, KS), for the detection of MRSA in nasal swab specimens. A total of 515 compliant remnant nasal swab specimens were sequentially used to inoculate BBL Trypticase soy agar with 5% sheep blood (TSA II) and each chromogenic medium. After 24 h of incubation, colony color reactions and morphology on chromogenic media were compared to suspicious colonies on nonselective TSA II. MRSA on TSA II was confirmed by Gram staining, a coagulase test, and a cefoxitin disk test. The overall prevalence of MRSA and methicillin-susceptible S. aureus (MSSA) on TSA II was 12.4% (64/515) and 9.7% (50/515), respectively. When each chromogenic medium was compared to the standard culture method, the sensitivity and specificity, respectively, were as follows: CMRSA II, 87.7% and 98.6%; MRSASelect, 89.0% and 93.4%; and Spectra MRSA, 83.6% and 92.1%. The positive predictive values were highest for CMRSA II (91.4%), followed by MRSASelect (69.1%) and Spectra MRSA (63.5%). False-positive results on chromogenic media were mainly due to color interpretation. The negative predictive values for all three media were greater than 97%. In conclusion, CMRSA II gave the best overall results for detecting MRSA from nasal specimens.
Collapse
|
18
|
Huh HJ, Kim ES, Chae SL. Methicillin-resistant Staphylococcus aureus in nasal surveillance swabs at an intensive care unit: an evaluation of the LightCycler MRSA advanced test. Ann Lab Med 2012; 32:407-12. [PMID: 23130339 PMCID: PMC3486934 DOI: 10.3343/alm.2012.32.6.407] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2012] [Revised: 07/23/2012] [Accepted: 09/19/2012] [Indexed: 12/04/2022] Open
Abstract
Background We compared the LightCycler MRSA advanced test (Roche Diagnostics, Germany) with enrichment culture methods to evaluate the relative diagnostic performance of the LightCycler MRSA advanced test for active surveillance in a high-prevalence setting. Methods A total of 342 nasal swab specimens were obtained from patients in the intensive care unit at admission and on the seventh day for follow-up. The results of LightCycler MRSA advanced test were compared to those of the enrichment culture. For discrepant results, mecA gene PCR was performed. Results For the detection of methicillin-resistant Staphylococcus aureus (MRSA), the LightCycler MRSA advanced test showed 98.5% sensitivity and 78.6% specificity and had positive and negative predictive values of 75.0% and 98.8%, respectively. A total of 46 samples had discrepant results between the LightCycler MRSA advanced test and enrichment culture. Of the 44 specimens that were positive in the LightCycler MRSA advanced test but negative by enrichment culture, mecA genes were detected in 37 specimens. In addition, of the original 44 cases, 21 patients had a history of MRSA colonization or infection within the last month; of those 21 specimens, 20 were positive for mecA gene as shown by PCR. Seven mecA-negative discrepant specimens comprised 3 methicillin-sensitive S. aureus-culture positive and only 2 patients had MRSA infections. Conclusions Despite its low specificity and positive predictive value, the LightCycler MRSA advanced test could serve as a rapid test for patients colonized with MRSA.
Collapse
Affiliation(s)
- Hee Jin Huh
- Department of Laboratory Medicine, Dongguk University Ilsan Hospital, Goyang, Korea
| | | | | |
Collapse
|
19
|
Zimmerman CE, Stamper PD, Bryant L, Farley J, Golova J, Holmberg R, Howard T, Linger Y, Meyers K, Perov A, Rudy GB, Carroll KC, Chandler DP. Development of a simple, low-density array to detect methicillin-resistant Staphylococcus aureus and mecA dropouts in nasal swabs. J Microbiol Methods 2012; 91:366-76. [PMID: 23041495 DOI: 10.1016/j.mimet.2012.09.010] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2012] [Revised: 09/10/2012] [Accepted: 09/11/2012] [Indexed: 01/22/2023]
Abstract
Detection of methicillin-resistant Staphylococcus aureus (MRSA) is important for prevention and control of MRSA infections, but the discovery of mecA dropouts and SCCmec junction sequences with homology to coagulase-negative staphylococci (CoNS) has challenged several real-time PCR tests. The objective of this study was to develop a user-friendly, gel element microarray test for MRSA detection, to estimate the analytical performance characteristics of the test on bacterial isolates, and to perform an initial evaluation of the test on nasopharyngeal swabs from patients known to have a high prevalence of S. aureus containing mecA dropouts. The assay limit of detection for the test was 250 fg (or less) of genomic DNA per amplification reaction (approximately 80 cell equivalents) and MRSA was consistently detected at a ratio of 1:12,000 in a non-target background. Of 87 bacterial isolates, the test accurately classified 86 (98.8%) overall, and correctly identified 14 mecA dropout specimens that were falsely positive in the BD GeneOhm MRSA test or BD GeneOhm StaphSR test. A retrospective analysis of 246 nasal swab samples acquired from a high-risk patient population (overall prevalence=10.8% by culture) resulted in 80.5% sensitivity (95% CI=68.4%, 92.6%) and 96.6% specificity. Of these 246 samples, 174 (71%) were positive for mecA, 86 (35%) were positive for S. aureus tufA and 46 (19%) were positive for a SCCmec junction sequence. To estimate method repeatability, 48 samples representing the full range of phenotypes, genotypes and microarray probe SNR values were tested in triplicate, with three discordant results for a concordance rate of 97.9% (141/144 tests). These data demonstrate that a very simple microarray test can identify mecA dropouts with high specificity in either cultured isolates or nasal swabs from a high-prevalence, high-risk patient population. However, the clinical sensitivity of the test will likely depend on local microbial ecology and the prevalence of mecA positive CoNS in any given patient population.
Collapse
Affiliation(s)
- Cynthia E Zimmerman
- Akonni Biosystems, Inc., 400 Sagner Avenue, Frederick, MD 21701, United States
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
20
|
Pithon MM, Santos RLD, Alviano WS, Ruellas ACDO, Araújo MTDS. Quantitative assessment of S. mutans and C. albicans in patients with Haas and Hyrax expanders. Dental Press J Orthod 2012. [DOI: 10.1590/s2176-94512012000300006] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|
21
|
Tübbicke A, Hübner C, Kramer A, Hübner NO, Fleßa S. Transmission rates, screening methods and costs of MRSA--a systematic literature review related to the prevalence in Germany. Eur J Clin Microbiol Infect Dis 2012; 31:2497-511. [PMID: 22573360 DOI: 10.1007/s10096-012-1632-8] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2012] [Accepted: 04/12/2012] [Indexed: 11/30/2022]
Abstract
Methicillin-resistant Staphylococcus aureus (MRSA) infections represent a serious challenge for health care institutions, which is inherent in the combination of prevalence, transmission rates and costs. Furthermore, performing an MRSA screening requires information on the complex system of effectiveness, accuracy and costs of different screening methods. The purpose of this study was to give an overview of parameters with decisive significance for the burden of MRSA and the selection of a specific MRSA screening strategy. A systematic literature search for peer-reviewed health economic studies associated with MRSA was performed (from 1995 to the present). Eighty-seven different studies met all inclusion and exclusion criteria. Primary outcomes included the prevalence of MRSA, MRSA transmission rates, performance characteristics of MRSA screening methods, costs for pre-emptive isolation precautions and costs per MRSA case. The prevalence rates reported for all inpatients (1.2-5.3 %) as well as for inpatients with risk factors or patients in risk areas (3.85-20.6 %) vary greatly. The range of cross-transmission rates per day reported for patients with MRSA in isolation is 0.00081-0.009 and for carriers not in isolation is 0.00137-0.140, respectively. For polymerase chain reaction (PCR) methods, the mean sensitivity and specificity were 91.09 and 95.79 %, respectively. Culture methods show an average sensitivity of 89.01 % and an average specificity of 93.21 %. The turn-around time for PCR methods averages 15 h, while for the culture method, it can only be estimated as 48-72 h. This review filtered important parameters and cost drivers, and covered them with literature-based averages. These findings serve as an ideal evidence base for further health economic considerations of the cost-effectiveness of different MRSA screening methods.
Collapse
Affiliation(s)
- A Tübbicke
- Institute of Health Care Management, Department of Law and Economics, University of Greifswald, Friedrich-Loeffler-Str. 70, 17489 Greifswald, Germany
| | | | | | | | | |
Collapse
|
22
|
RNA signatures allow rapid identification of pathogens and antibiotic susceptibilities. Proc Natl Acad Sci U S A 2012; 109:6217-22. [PMID: 22474362 DOI: 10.1073/pnas.1119540109] [Citation(s) in RCA: 80] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
With rising rates of drug-resistant infections, there is a need for diagnostic methods that rapidly can detect the presence of pathogens and reveal their susceptibility to antibiotics. Here we propose an approach to diagnosing the presence and drug-susceptibility of infectious diseases based on direct detection of RNA from clinical samples. We demonstrate that species-specific RNA signatures can be used to identify a broad spectrum of infectious agents, including bacteria, viruses, yeast, and parasites. Moreover, we show that the behavior of a small set of bacterial transcripts after a brief antibiotic pulse can rapidly differentiate drug-susceptible and -resistant organisms and that these measurements can be made directly from clinical materials. Thus, transcriptional signatures could form the basis of a uniform diagnostic platform applicable across a broad range of infectious agents.
Collapse
|
23
|
|
24
|
Taguchi H, Matsumoto T, Ishikawa H, Ohta S, Yukioka T. Prevalence of methicillin-resistant Staphylococcus aureus based on culture and PCR in inpatients at a tertiary care center in Tokyo, Japan. J Infect Chemother 2012; 18:630-6. [PMID: 22358543 DOI: 10.1007/s10156-012-0385-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2010] [Accepted: 01/26/2012] [Indexed: 10/28/2022]
Abstract
We investigated active screening for colonization with methicillin-resistant Staphylococcus aureus (MRSA) on admission and weekly follow-up surveillance after admission to a tertiary care center (TCC) between June 2007 and 31 December 2007. Eleven percent (30/267) of patients were found to be positive for MRSA by polymerase chain reaction (PCR) and/or culture on admission; 5% (12/267) became positive during the TCC stay. The major primary diagnoses in MRSA-positive patients were pneumonia and cerebrovascular diseases. Twenty-two (52%) of 42 patients were found to be MRSA positive by both PCR and culture, compared with 19 (45%) of 42 who were PCR positive and culture negative. These findings suggest that active surveillance with PCR is highly sensitive and useful for the detection of MRSA colonization. To our knowledge, this is the first report of active surveillance of MRSA by PCR and bacterial culture in critically ill inpatients in Japan.
Collapse
Affiliation(s)
- Hirokazu Taguchi
- Department of Emergency and Critical Care Medicine, Tokyo Medical University, 6-7-1 Nishi-shinjuku, Sinjuku, Tokyo, 160-0023, Japan.
| | | | | | | | | |
Collapse
|
25
|
Rapid confirmation of suspected methicillin-resistant Staphylococcus aureus colonies on chromogenic agars by a new commercial PCR assay, the GenomEra MRSA/SA Diagnose. Eur J Clin Microbiol Infect Dis 2012; 31:1961-8. [PMID: 22278292 DOI: 10.1007/s10096-011-1527-0] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2011] [Accepted: 12/15/2011] [Indexed: 12/21/2022]
Abstract
A new automated closed tube PCR assay, the GenomEra(™) MRSA/SA Diagnose (Abacus Diagnostica Oy, Finland) was evaluated for rapid confirmation of methicillin-resistant Staphylococcus aureus (MRSA) from cultured screening specimens. The ability of the assay to detect genotypically different MRSA strains was studied with a collection of 304 MRSA isolates covering 68 spa types. The specificity was investigated with a collection of 146 non-MRSA staphylococcus isolates. The usefulness of the assay for clinical purposes was assessed by a sequential combination of MRSA screening culture and confirmation of the colonies with the GenomEra MRSA/SA Diagnose assay. A total of 145 suspected MRSA colonies on chromogenic plates were analyzed this way. All MRSA isolates from the culture collection and from the clinical screening specimens were confirmed as MRSA with the GenomEra MRSA/SA Diagnose assay and none of the non-MRSA staphylococci caused false-positive results, which indicates both sensitivity and specificity of 100%. The combination of GenomEra MRSA/SA Diagnose with preceding culture on selective MRSA agar permitted MRSA confirmation within 24 h. This practice offers a reliable and quick detection of MRSA that is also suitable in areas where several strain types cause epidemics.
Collapse
|
26
|
Yadav MK, Kwon SK, Huh HJ, Chae SW, Song JJ. Detection of methicillin-resistant Staphylococcus aureus (MRSA) from nasal samples by multiplex real-time PCR based on dual priming AT-rich primers. Folia Microbiol (Praha) 2011; 57:37-45. [PMID: 22187362 DOI: 10.1007/s12223-011-0085-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2011] [Accepted: 10/25/2011] [Indexed: 10/14/2022]
Abstract
In this study, we reported on the design of a multiplex real-time PCR assay based on SYBR Green I, incorporating dual priming adenine-thymine (AT)-rich primers for direct detection of MRSA from nasal samples. The multiplex real-time polymerase chain reaction (RT-PCR) assay reported in this study is based on SYBR Green I with incorporation of six dual priming AT-rich primers designed from the SCCmec/orf junction. A string (4-6 bp) of low-melting bases, such as adenine and thymine, was incorporated into the primers, which virtually divided a single primer in two functional regions, thus decreasing non-specific PCR products. The analytical sensitivity and specificity of the RT-PCR assay was determined with genomic DNA of reference strains (MRSA, MSSA, and MRCoNS). RT-PCR assay was performed for analysis of 72 nasal swab specimens, and the results were confirmed by use of a culture method. Furthermore, the results of RT-PCR were compared with LightCycler MRSA advance test. The multiplex RT-PCR assay reproducibly detected a minimum of 1 pg genomic DNA (31.5 copy of genome) of MRSA reference strains and clinical isolates, with a specific melting peak at 83.5 ± 1.5°C, and neither fluorescence nor a melting peak was detected in non-target isolates. The concordance rate between RT-PCR assay and culture method was 87.5% with Cohen's kappa value (κ) 0.75, which showed good agreement between the two assays. The sensitivity, specificity, positive predictive value, and negative predictive value of the assay were 93.5%, 82.9%, 80.5%, and 94.4%, respectively. In a comparative study for the detection of 72 nasal samples, the sensitivity, specificity, positive predictive value, and negative predictive value of the multiplex RT-PCR assay with respect to LightCycler MRSA advance test was 84.2%, 88.2%, 89%, and, 83.3%, respectively. The results of RT-PCR assay demonstrated high specificity (88.2%) and positive predictive value (89%) for the direct detection of MRSA from nasal samples.
Collapse
Affiliation(s)
- M K Yadav
- Department of Otorhinolaryngology-Head and Neck Surgery, Dongguk University Ilsan Hospital, Goyang, Gyeonggi, South Korea
| | | | | | | | | |
Collapse
|
27
|
Evaluation of the BD GeneOhm MRSA and VanR Assays as a Rapid Screening Tool for Detection of Methicillin-Resistant Staphylococcus aureus and Vancomycin-Resistant Enterococci in a Tertiary Hospital in Saudi Arabia. Int J Microbiol 2011; 2011:861514. [PMID: 22187558 PMCID: PMC3236454 DOI: 10.1155/2011/861514] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2011] [Accepted: 10/17/2011] [Indexed: 12/01/2022] Open
Abstract
Objectives. The aim of this study was to evaluate the diagnostic performance of BD GeneOhm VanR Assay, a rapid PCR test that detects the presence of vanA and/or vanB genes and the performance of BDGeneOhm MRSA Assay which detects the staphylococcal cassette chromosomemec (SCCmec cassette) carrying the mecA gene and Staphylococcus aureus specific sequence located within the orfX gene. Methods. 300 duplicate rectal swabs collected consecutively were analyzed for the presence of VRE by culture and BD PCR. 2267 duplicate swabs were collected (728 nasal and 1539 groin swabs) and analyzed for the presence of MRSA by culture method and BD PCR. Results. Compared to culture, the BD GeneOhm VanR Assay showed a sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of 100%, 91.1%, 23.5%, and 100%, respectively. The BD GeneOhm MRSA Assay revealed sensitivity, specificity, PPV, and NPV of 97.2%, 99.4%, 89.7%, and 99.9%, respectively, for nasal swabs. For groin swabs, it was 100%, 98.7%, 61.5% and 100%, respectively. Conclusion. The BD GeneOhm vanR Assay is a good screening test for rapid exclusion of VRE carriers in hospitals. The BD GeneOhm MRSA Assay represents a reliable screening test. The true strength of the BD GeneOhm Assay for MRSA and VRE is its exceptionally high NPV making the test an ideal tool for rapid exclusion of MRSA and VRE carriers in hospitals. As a consequence, this would dramatically shorten the patient isolation time.
Collapse
|
28
|
Bailey RR, Stuckey DR, Norman BA, Duggan AP, Bacon KM, Connor DL, Lee I, Muder RR, Lee BY. Economic value of dispensing home-based preoperative chlorhexidine bathing cloths to prevent surgical site infection. Infect Control Hosp Epidemiol 2011; 32:465-71. [PMID: 21515977 DOI: 10.1086/659763] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
OBJECTIVE To estimate the economic value of dispensing preoperative home-based chlorhexidine bathing cloth kits to orthopedic patients to prevent surgical site infection (SSI). METHODS A stochastic decision-analytic computer simulation model was developed from the hospital's perspective depicting the decision of whether to dispense the kits preoperatively to orthopedic patients. We varied patient age, cloth cost, SSI-attributable excess length of stay, cost per bed-day, patient compliance with the regimen, and cloth antimicrobial efficacy to determine which variables were the most significant drivers of the model's outcomes. RESULTS When all other variables remained at baseline and cloth efficacy was at least 50%, patient compliance only had to be half of baseline (baseline mean, 15.3%; range, 8.23%-20.0%) for chlorhexidine cloths to remain the dominant strategy (ie, less costly and providing better health outcomes). When cloth efficacy fell to 10%, 1.5 times the baseline bathing compliance also afforded dominance of the preoperative bath. CONCLUSIONS The results of our study favor the routine distribution of bathing kits. Even with low patient compliance and cloth efficacy values, distribution of bathing kits is an economically beneficial strategy for the prevention of SSI.
Collapse
Affiliation(s)
- Rachel R Bailey
- Public Health Computational and Operations Research Group, University of Pittsburgh, Pittsburgh, 3520 Forbes Avenue, First Floor, Pennsylvania 15213, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|
29
|
Prevalence and genetic relatedness of methicillin-susceptible Staphylococcus aureus isolates detected by the Xpert MRSA nasal assay. J Clin Microbiol 2011; 49:2996-9. [PMID: 21677066 DOI: 10.1128/jcm.00046-11] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023] Open
Abstract
Methicillin-susceptible Staphylococcus aureus (MSSA) isolates lacking mecA yet testing positive on the Xpert MRSA assay were recovered from culture for 7.7% of 248 Xpert-positive nasal samples. These "false-positive" Xpert results may be attributed to staphylococcal cassette chromosome (SCC) elements without the mecA gene. Pulsed-field gel electrophoresis (PFGE) analysis revealed a diverse population of MSSA strains.
Collapse
|
30
|
Chen WT, Wang JT, Lee WS, Huang CH, Liao CH, Chen YC, Chang SC. Performance of the BD GeneOhm methicillin-resistant Staphylococcus aureus (MRSA) PCR assay for detecting MRSA nasal colonization in Taiwanese adults. JOURNAL OF MICROBIOLOGY, IMMUNOLOGY, AND INFECTION = WEI MIAN YU GAN RAN ZA ZHI 2011; 43:372-7. [PMID: 21075703 DOI: 10.1016/s1684-1182(10)60059-x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/12/2008] [Revised: 03/24/2009] [Accepted: 08/18/2009] [Indexed: 12/29/2022]
Abstract
BACKGROUND/PURPOSE A rapid diagnostic method for methicillin-resistant Staphylococcus aureus (MRSA) has been implemented for surveillance of the at-risk population, but its performance in those without traditional risk factors is not clear. The objective of this study was to evaluate MRSA colonization status by comparing the performance of the BD GeneOhm MRSA polymerase chain reaction (PCR) assay with that of conventional culture during a 3-month active surveillance of Taiwanese adults in the community. METHODS From 1 October 2007 to 28 December 2007, adults (≥ 18 years old) attending a mandatory health examination arranged by their employers as a part of the workplace health promotion program at three medical centers in northern Taiwan were enrolled in the study. No healthcare workers were included. A total of 498 paired nasal swabs were prospectively obtained and used for both the BD GeneOhm MRSA PCR assay and conventional culture. RESULTS Of the 498 paired nasal swabs, 14 (2.8%) were positive for MRSA by conventional culture and 34 (6.8%) were positive by the BD GeneOhm MRSA PCR assay (p < 0.005). Thirteen specimens were both culture- and PCR-positive, and 463 samples were both culture- and PCR-negative. There were two discordant results: 21 specimens were culture-negative/PCR-positive, and one was culture-positive/PCR-negative. The simple kappa coefficient for measuring the agreement between conventional culture and the MRSA PCR assay was 0.52. CONCLUSION This study demonstrates the feasibility of using both the MRSA PCR assay and conventional culture as surveillance tools. Also, the MRSA-positive rate detected by MRSA PCR assay was significantly higher than that of conventional culture.
Collapse
Affiliation(s)
- Wei-Ting Chen
- Department of Internal Medicine, National Taiwan University Hospital, Taipei, Taiwan
| | | | | | | | | | | | | |
Collapse
|
31
|
Rapid differentiation of methicillin-resistant and methicillin-susceptible Staphylococcus aureus by flow cytometry after brief antibiotic exposure. J Clin Microbiol 2011; 49:2116-20. [PMID: 21471343 DOI: 10.1128/jcm.02548-10] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
We noticed that methicillin-resistant Staphylococcus aureus (MRSA) and methicillin-susceptible S. aureus (MSSA) isolates yielded side-scatter (SSC) and fluorescence intensity (FI) differences on flow cytometry (FCM) following incubation in oxacillin broth. The purpose of this study was to determine whether MRSA and MSSA could be reliably differentiated by FCM. S. aureus isolates were incubated in oxacillin-containing Mueller-Hinton broth, stained using the FASTEST total viable organisms kit, and analyzed by FCM in the MicroPRO instrument. SSC versus FI were examined, and gates 1 and 2 were defined to encompass the majority of MSSA and MRSA signal events, respectively. A count ratio (CR) was defined as the ratio of counts in gate 2 to those in gate 1. Initially, 33 isolates were tested after 4 h of incubation for proof-of-concept. Twenty others were then tested after incubation intervals ranging from 30 min to 4 h to determine the earliest possible time for differentiation. Next, 100 separate isolates were tested to determine the best CR cutoff value. Finally, the CR was validated by using an independent cohort of 121 isolates. We noted that MRSA isolates had higher SSC and FI readings than did MSSA isolates after 2 h of incubation. The receiver-operator characteristics curve showed that a CR cutoff of 0.0445 reliably differentiated MRSA from MSSA. In the validation cohort, this cutoff had a sensitivity of 100% and a specificity of 98.7% for identifying MRSA from among S. aureus isolates, following 2 h of incubation. This study demonstrates that MRSA and MSSA can be accurately differentiated by FCM after 2 h of incubation in an oxacillin-containing liquid culture medium.
Collapse
|
32
|
Genotypic and phenotypic characterization of methicillin-susceptible Staphylococcus aureus isolates misidentified as methicillin-resistant Staphylococcus aureus by the BD GeneOhm MRSA assay. J Clin Microbiol 2011; 49:1240-4. [PMID: 21307210 DOI: 10.1128/jcm.02220-10] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023] Open
Abstract
Twenty-three nasal swab samples that tested positive for methicillin-resistant Staphylococcus aureus (MRSA) on initial testing by the BD GeneOhm MRSA assay (BD-MRSA PCR; BD GeneOhm, San Diego, CA) were culture positive only for methicillin-susceptible S. aureus (MSSA) from an enrichment broth. The 23 recovered isolates were confirmed as MSSA by a variety of phenotypic methods, including the BD Phoenix automated microbiology system (BD Diagnostics, Sparks, MD), oxacillin screening agar (BD Diagnostics), BBL CHROMagar MRSA (BD Diagnostics), and a PBP2' assay (Denka Seiken Co., Tokyo, Japan); susceptibilities were determined by using Mueller-Hinton agar with oxacillin. All were positive by nuc PCR, specific for S. aureus, but negative for mecA with one exception. Isolates were characterized by using multiplex PCR methodology to determine structural types and variants (SCCmec typing); additional PCRs were performed for the detection of the ccr and mec complexes, the junkyard regions as well as the Panton-Valentine leukocidin. Pulsed-field gel electrophoresis was used to determine clonality. One phenotypic MSSA isolate contained an intact SCCmec. Twelve MSSA isolates tested positive for MRSA by the BD-MRSA PCR because of amplification of the mec priming site flanking the SCC insertion point, although these isolates lacked mecA. The 10 remaining isolates were not MRSA and tested as MSSA by phenotypic and genotypic assays. In our patient population, diagnostic and surveillance testing and subsequent infection control practices may be impacted by the frequency of these excision events when using the BD-MRSA PCR for MRSA detection.
Collapse
|
33
|
Evaluation of molecular assays for rapid detection of methicillin-resistant Staphylococcus aureus. J Clin Microbiol 2010; 48:4598-601. [PMID: 20943869 DOI: 10.1128/jcm.00004-10] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022] Open
Abstract
The diagnostic sensitivities of the BD GeneOhm and Cepheid Xpert assays were compared using culture on log-serial dilutions of well-characterized methicillin-resistant Staphylococcus aureus (MRSA) and non-MRSA strains and on nasal and groin swabs from patients with histories of MRSA carriage. The sensitivities of GeneOhm and Xpert were high at 10(3)-CFU/ml MRSA concentrations (92.3% and 96.3%, respectively) although decreased considerably (<35%) at a 1-log-lower concentration. Unexpectedly, both assays also detected select coagulase-negative staphylococci, which requires further evaluation.
Collapse
|
34
|
Detection of methicillin-resistant Staphylococcus aureus (MRSA) in specimens from various body sites: performance characteristics of the BD GeneOhm MRSA assay, the Xpert MRSA assay, and broth-enriched culture in an area with a low prevalence of MRSA infections. J Clin Microbiol 2010; 48:3882-7. [PMID: 20861339 DOI: 10.1128/jcm.00670-10] [Citation(s) in RCA: 54] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
Universal surveillance upon patient admission is important in reducing the transmission of methicillin-resistant Staphylococcus aureus (MRSA) and associated disease in hospitals. High costs for the health care system in conjunction with MRSA have promoted the development of rapid screening methods to detect MRSA carriers. This study compared two real-time PCR methods, the BD GeneOhm MRSA assay (BDGO) and the Xpert MRSA assay, with broth-enriched culture to define their performance characteristics and rapidity in an area with low MRSA prevalence. In total, 414 swabs from the nose and 389 swabs from the groin from 425 patients were tested. Of those 425 patients, 378 had swabs from both the nose and groin in parallel. Two hundred thirty-one and 194 patients were randomly assigned to the BDGO group and the Xpert MRSA group, respectively. In general, sensitivity, specificity, and negative predictive value (NPV) were high for the BDGO (100%, 98.5%, and 100%, respectively) and the Xpert MRSA (100%, 98.2%, and 100%, respectively), irrespective of whether or not nasal and inguinal specimens were considered alone or combined. In contrast, the positive predictive value (PPV) was lower: before the resolution of discrepant results, the PPVs for nasal and inguinal specimens alone and combined were 87.5%, 86.7%, and 82.4% for the BDGO and 91.7%, 66.7%, and 92.9% for the Xpert MRSA, respectively. After the resolution of discrepant results, PPVs were 93.8%, 93.3% and 94.1% for the BDGO and 91.7%, 88.9% and 92.9% for the Xpert MRSA, respectively. With the BDGO, 4 of 16 carriers were each identified by nasal or inguinal swabs alone, whereas in the Xpert MRSA group, 4 of 13 carriers were exclusively identified by nasal swabs and 2 of 13 were identified by inguinal swabs alone. Both PCR methods showed no significant difference in the number of discrepant results (odds ratio, 0.70 [P = 0.789]), but specimens from wounds and other body sites (axilla, vagina, and throat) produced discrepancies more often than nasal and groin specimens (odds ratios, 4.724 [P = 0.058] and 12.163 [P < 0.001], respectively). The facts that no false-negative PCR results were detected and increased PPVs were found after the resolution of discrepant results point to PCR as the actual gold standard. Since both sensitivity and NPV were exceptionally high for PCR, backup cultures may, therefore, be unnecessary in an area with low prevalence and with a preemptive isolation strategy but may still be useful for PCR-positive specimens because of the lower PPV for both methods and the possibility of susceptibility testing. The median time for analysis, including extraction, hands-on time, and actual PCR was 2 h 20 min for the Xpert MRSA versus 5 h 40 min for the BDGO. Concerning reporting time, including administration and specimen collection, the Xpert MRSA was faster than the BDGO (7 h 50 min versus 17 h).
Collapse
|
35
|
Abstract
Staphylococcus aureus has been recognized as an important human pathogen for more than 100 years. S aureus has been able to adapt and evolve in terms of its resistance traits and virulence factors; it is among the most important causes of human infections in the twenty-first century. Rapid molecular identification in the clinical microbiology laboratory of these resistance and virulence factors expressed by S aureus will play an important role in the future in decreasing the morbidity and mortality of infections. This article addresses the emerging aspects of infections caused by S aureus, including microbiology, epidemiology, clinical presentation, pathogenesis, diagnosis, treatment and prognosis, and immunity.
Collapse
|
36
|
The performance of the BD geneOhm MRSA™ assay for MRSA isolated from clinical patients in Japan, including the effects of specimen contamination and ways to improve it. J Infect Chemother 2010; 17:214-8. [PMID: 20714914 DOI: 10.1007/s10156-010-0104-2] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2010] [Accepted: 07/23/2010] [Indexed: 10/19/2022]
Abstract
The BD geneOhm MRSA™ assay has been increasingly used in recent years, and it is possible to use it to screen and detect methicillin-resistant Staphylococcus aureus (MRSA) from a specimen within 2 h. The purpose of the present study was to evaluate the performance, i.e., the specificity and sensitivity, of the BD geneOhm MRSA™ assay to detect MRSA. Its specificity was assessed to be 100% compared to bacterial culture methods, which are commonly used in medical laboratories. Its bacterial limit of detection was over 10 colony-forming units (cfu) per reaction, although MRSA was detected at a cfu below 10 per reaction in a few samples. Additionally, the effect of MRSA isolate contamination was examined. While contamination with protein or other bacteria did not affect the outcome, contamination with a high concentration of blood resulted in an unresolved outcome. To inactivate polymerase chain reaction (PCR) inhibitors, the DNA samples were freeze-thawed prior to the BD geneOhm MRSA™ assay, which led to the sensitivity of the assay increasing. In summary, the BD geneOhm MRSA™ assay is rapid and shows high specificity and sensitivity of cultured MRSA isolates. It will, therefore, be a valuable diagnostic tool for detecting MRSA in specimens from clinical patients.
Collapse
|
37
|
Characterization of Staphylococcus aureus isolates with a partial or complete absence of staphylococcal cassette chromosome elements. J Clin Microbiol 2010; 48:3525-31. [PMID: 20668131 DOI: 10.1128/jcm.00775-10] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Detection of methicillin-resistant Staphylococcus aureus (MRSA) by single-locus PCR assays that target the extremity of the staphylococcal cassette chromosome-mec (SCCmec) and part of the adjacent S. aureus-specific open reading frame gene (orfX) is a significant diagnostic advancement, since it provides real-time detection directly from screening specimens. However, isolates harboring mecA deletions within SCCmec may result in false-positive identification of MRSA in these assays. We characterized 24 methicillin-susceptible S. aureus (MSSA) isolates that tested positive in one such assay to investigate this phenomenon. Seven isolates resembled USA100 and carried SCCmec II elements with mecA deletions that spanned 20 to 46 kbp. The mecA excisions in USA100-resembling isolates appeared to be linked with IS431 transposable elements present in SCCmec II. For 17 isolates that resembled USA400 and/or MSSA476, the identity and possible excision of SCC elements could not be confirmed. The downstream common sequence (dcs) shared by SCCmec I, II, and IV elements was detected in these isolates. Sequence analysis of the chromosomal regions flanking the missing SCC element revealed an intact SCC integration site, a duplicate dcs, and the enterotoxin gene cluster downstream of orfX. An annealing sequence for one of the SCCmec-specific primers (mecii574) in the single-locus PCR assay was identified in the duplicate dcs. In the absence of SCC, a 176-bp amplicon can be generated from this mecii574 annealing sequence to yield a false-positive result. In conclusion, partial SCCmec II excisions via IS431 elements in strains that resembled USA100 and the presence of a duplicate mecii574 annealing sequence in strains that resembled USA400/MSSA476 were identified as causes for false-positive results in a single-locus PCR assay that targets the SCCmec/orfX junction.
Collapse
|
38
|
Milstone AM, Carroll KC, Ross T, Shangraw KA, Perl TM. Community-associated methicillin-resistant Staphylococcus aureus strains in pediatric intensive care unit. Emerg Infect Dis 2010; 16:647-55. [PMID: 20350379 PMCID: PMC3321932 DOI: 10.3201/eid1604.090107] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
Virulent community-associated methicillin-resistant Staphylococcus-aureus (CA-MRSA) strains have spread rapidly in the United States. To characterize the degree to which CA-MRSA strains are imported into and transmitted in pediatric intensive care units (PICU), we performed a retrospective study of children admitted to The Johns Hopkins Hospital PICU, March 1, 2007-May 31, 2008. We found that 72 (6%) of 1,674 PICU patients were colonized with MRSA. MRSA-colonized patients were more likely to be younger (median age 3 years vs. 5 years; p = 0.02) and African American (p<0.001) and to have been hospitalized within 12 months (p<0.001) than were noncolonized patients. MRSA isolates from 66 (92%) colonized patients were fingerprinted; 40 (61%) were genotypically CA-MRSA strains. CA-MRSA strains were isolated from 50% of patients who became colonized with MRSA and caused the only hospital-acquired MRSA catheter-associated bloodstream infection in the cohort. Epidemic CA-MRSA strains are becoming endemic to PICUs, can be transmitted to hospitalized children, and can cause invasive hospital-acquired infections. Further appraisal of MRSA control is needed.
Collapse
Affiliation(s)
- Aaron M Milstone
- Department of Pediatric Infectious Diseases, The Johns Hopkins University School of Medicine, 200 N Wolfe St, Rubenstein 3141, Baltimore, MD 21287, USA.
| | | | | | | | | |
Collapse
|
39
|
Evaluation of the Xpert MRSA assay for rapid detection of methicillin-resistant Staphylococcus aureus from nares swabs of geriatric hospitalized patients and failure to detect a specific SCCmec type IV variant. Eur J Clin Microbiol Infect Dis 2010; 29:995-1002. [PMID: 20512518 DOI: 10.1007/s10096-010-0958-3] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2010] [Accepted: 05/06/2010] [Indexed: 12/11/2022]
Abstract
Rapid and reliable detection of methicillin-resistant Staphylococcus aureus (MRSA) carriers is crucial for control of MRSA nosocomial transmission. We aimed to evaluate the performance of the GeneXpert real-time PCR system using the Xpert MRSA assay on a collection of 40 representative Belgian MRSA strains and for MRSA screening of geriatric inpatients. Double nasal swabs were used: the first swab for the Xpert MRSA assay and the second for culture onto chromogenic selective medium and enrichment broth. All but 1 of the 40 collection strains were recognized as MRSA by the Xpert MRSA assay. Nares swabs were prospectively collected from 246 inpatients including 25 nasal MRSA carriers. Compared with enriched cultures, the sensitivity, the specificity, and the positive and negative predictive values of the Xpert MRSA assay were 69.2%, 97.7%, 78.3%, and 96.3% respectively. The 7 evaluable false-negative results according to the assay were due to its possible lack of sensitivity (n = 3) and to the occurrence of a Belgian MRSA clone carrying a particular staphylococcal chromosomal cassette mec (SCCmec) type IV variant (n = 4) not targeted by the current Xpert MRSA assay. Because of the evolution of SCCmec in MRSA, new primers should be designed and further studies are warranted to ensure continuous monitoring of this assay.
Collapse
|
40
|
Park SH, Jang YH, Sung H, Kim MN, Kim JS, Park YJ. [Performance evaluation of BD GeneOhm MRSA PCR assay for detection of nasal colonization of methicillin-resistant Staphylococcus aureus at endemic intensive care units]. Korean J Lab Med 2010; 29:439-47. [PMID: 19893353 DOI: 10.3343/kjlm.2009.29.5.439] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
BACKGROUND The BD GeneOhm MRSA PCR assay (Becton Dickinson, USA) is a qualitative real-time PCR test for rapid detection of nasal colonization of methicillin-resistant Staphylococcus aureus (MRSA). We evaluated the performance of BD GeneOhm MRSA PCR assay versus MRSASelect (Bio-Rad, France) and broth enrichment cultures for detection of MRSA from nasal swabs. METHODS From August 2008 to January 2009, 295 nasal swabs were taken from patients in intensive care units and transported to the laboratory with BD CultureSwab Liquid Stuart Single Swab (Becton Dickinson, USA). The swabs were inoculated onto MRSASelect first and then suspended into GeneOhm sample buffer: 100 microL of the suspension was inoculated into 6.5% NaCl-tryptic soy broth (Becton Dickinson, USA), which was subcultured on MRSASelect after overnight incubation (TSBS). Performances of GeneOhm MRSA and MRSASelect were compared to TSBS. RESULTS With GeneOhm MRSA, 125 swabs (44.6%) were positive for MRSA, 13 (4.4%) were unresolved, and 2 were not determined. With MRSASelect and TSBS 86 (29.4%) and 106 swabs (36.2%), respectively, were positive. The sensitivity, specificity, and positive and negative predictive value of GeneOhm MRSA were 85.8%, 77.5%, and 72.8% and 93.5%, respectively, and corresponding values for MRSASelect were 78.3%, 94.8%, and 96.5% and 88.9%. Of the 33 patients whose 34 specimens were found false positive in GeneOhm MRSA, 23 patients were MRSA-positive either previously or subsequently to this study. All of the 10 patients with false-negative specimens in GeneOhm MRSA PCR assay were previously MRSA or methicilln-resistant coagulase negative staphylococci (MRCNS)-positive and were treated for MRSA, but they became MRSA-positive after 1 to 4 negative surveillance cultures. CONCLUSIONS GeneOhm MRSA PCR assay showed a relatively high negative predictive value. However, its low specificity and frequent occurrence of unresolved results would be problematic in the endemic areas with a high prevalence of MRSA.
Collapse
Affiliation(s)
- Sang Hyuk Park
- Department of Laboratory Medicine, University of Ulsan College of Medicine, Seoul, Korea
| | | | | | | | | | | |
Collapse
|
41
|
Comparison of the BD GeneOhm methicillin-resistant Staphylococcus aureus (MRSA) PCR assay to culture by use of BBL CHROMagar MRSA for detection of MRSA in nasal surveillance cultures from intensive care unit patients. J Clin Microbiol 2010; 48:1305-9. [PMID: 20181916 DOI: 10.1128/jcm.01326-09] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
This study compared the BD GeneOhm methicillin-resistant Staphylococcus aureus (MRSA) real-time PCR assay to culture by the use of BBL CHROMagar MRSA for the detection of MRSA in 627 nasal surveillance specimens collected from intensive care unit (ICU) patients. The PCR assay had a sensitivity, specificity, positive predictive value, and negative predictive value of 100%, 96.7%, 70.3%, and 100%, respectively. Nine of 19 false-positive PCR specimens grew methicillin-susceptible S. aureus (MSSA) from broth enrichment culture, of which two demonstrated evidence of mecA gene dropout. Compared to culture by the use of BBL CHROMagar MRSA, the BD GeneOhm MRSA PCR assay demonstrated sensitivity and specificity above 95% for the detection of MRSA nasal colonization and provided shorter turnaround time in generating positive and negative final results.
Collapse
|
42
|
Rapid detection of methicillin-resistant Staphylococcus aureus (MRSA) in diverse clinical specimens by the BD GeneOhm MRSA assay and comparison with culture. J Clin Microbiol 2010; 48:981-4. [PMID: 20071545 DOI: 10.1128/jcm.01990-09] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
The efficacy of the BD GeneOhm methicillin-resistant Staphylococcus aureus (MRSA) assay was assessed by analyzing nasal swabs and swabs from other body sites for the presence of MRSA in a low-prevalence area. From 681 patients with a high risk for MRSA carriage, 1,601 specimens were collected and transported in Amies agar. After discordant analysis, the sensitivity, specificity, positive predictive value, and negative predictive value of the BD GeneOhm MRSA assay were 84.3%, 99.2%, 88.4%, and 98.9%, respectively, compared to culture.
Collapse
|
43
|
Clinical application of real-time PCR to screening critically ill and emergency-care surgical patients for methicillin-resistant Staphylococcus aureus: a quantitative analytical study. J Clin Microbiol 2009; 47:4102-8. [PMID: 19846648 DOI: 10.1128/jcm.01332-09] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
The clinical utility of real-time PCR screening assays for methicillin (methicillin)-resistant Staphylococcus aureus (MRSA) colonization is constrained by the predictive values of their results: as MRSA prevalence falls, the assay's positive predictive value (PPV) drops, and a rising proportion of positive PCR assays will not be confirmed by culture. We provide a quantitative analysis of universal PCR screening of critical care and emergency surgical patients using the BD GeneOhm MRSA PCR system, involving 3,294 assays over six months. A total of 248 PCR assays (7.7%) were positive; however, 88 failed to be confirmed by culture, giving a PPV of 65%. Multivariate analysis was performed to compare PCR-positive culture-positive (P+C+) and PCR-positive culture-negative (P+C-) assays. P+C- results were positively associated with a history of methicillin-sensitive Staphylococcus aureus infection or colonization (odds ratio [OR], 3.15; 95% confidence interval [CI], 1.32 to 7.54) and high PCR thresholds of signal intensity, indicative of a low concentration of target DNA (OR, 1.19 per cycle; 95% CI, 1.11 to 1.26). P+C- results were negatively associated with a history of MRSA infection or colonization (OR, 0.19; 95% CI, 0.09 to 0.42) and male sex (OR, 0.40; 95% CI, 0.20 to 0.81). P+C+ patients were significantly more likely to have subsequent positive MRSA culture assays and microbiological evidence of clinical MRSA infection. The risk of subsequent MRSA infection in P+C- patients was not significantly different from that in case-matched PCR-negative controls. We conclude that, given the low PPV and poor correlation between a PCR-positive assay and the clinical outcome, it would be prudent to await culture confirmation before altering infection control measures on the basis of a positive PCR result.
Collapse
|
44
|
Dalla Valle C, Pasca MR, De Vitis D, Marzani FC, Emmi V, Marone P. Control of MRSA infection and colonisation in an intensive care unit by GeneOhm MRSA assay and culture methods. BMC Infect Dis 2009; 9:137. [PMID: 19703294 PMCID: PMC2738678 DOI: 10.1186/1471-2334-9-137] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2009] [Accepted: 08/24/2009] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Methicillin-resistant Staphylococcus aureus (MRSA) is one of the major nosocomial pathogens. Due to the diffusion of MRSA strains in both hospital and community settings, prevention and control strategies are receiving increased attention. Approximately 25% to 30% of the population is colonised with S. aureus and 0.2% to 7% with MRSA. The BD GeneOhm MRSA real-time PCR assay offers quicker identification of MRSA-colonised patients than do culture methods. METHODS Ninety-five patients admitted to the Intensive Care Unit of IRCCS Policlinico San Matteo of Pavia (Italy) for a period > 24 h were screened for MRSA colonisation with both the culture method and the GeneOhm assay. RESULTS Of the 246 nasal swabs collected from 95 patients, 36 samples were found to be positive by both methods (true-positive). 30% of colonised patients had developed the MRSA infection. CONCLUSION Our results show that the GeneOhm MRSA assay is a valuable diagnostic tool for detecting MRSA quickly in nasal swabs. This study confirms that colonisation represents a high risk factor for MRSA infection, and that good MRSA surveillance in an Intensive Care Unit is therefore an excellent way to prevent MRSA infection.
Collapse
Affiliation(s)
- Claudia Dalla Valle
- Laboratorio di Batteriologia e Micologia, Area Infettivologica, Fondazione IRCCS S, Matteo, Pavia, Italia.
| | | | | | | | | | | |
Collapse
|
45
|
Tom TSM, Kruse MW, Reichman RT. Update: Methicillin-resistant Staphylococcus aureus screening and decolonization in cardiac surgery. Ann Thorac Surg 2009; 88:695-702. [PMID: 19632455 DOI: 10.1016/j.athoracsur.2009.02.010] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/13/2008] [Revised: 02/04/2009] [Accepted: 02/06/2009] [Indexed: 01/28/2023]
Abstract
Methicillin-resistant Staphylococcus aureus (MRSA) has become a concerning multidrug-resistant organism, expanding further outside the hospital setting. Cardiothoracic surgery patients are at an increased risk for mediastinitis and other surgical site infections, which may be further complicated by MRSA. To reduce MRSA surgical site infections, multidisciplinary active surveillance should be implemented in at least high-risk patients, incorporating basic infection control practices, appropriate antibiotic prophylaxis, and decolonization. This article will review the various guidelines, addressing the role of MRSA active surveillance in cardiothoracic surgery, and provide guidance for cardiothoracic surgeons.
Collapse
Affiliation(s)
- Trisha S M Tom
- Department of Pharmacy, Deaconess Medical Center, Washington State University, Spokane, Washington, USA
| | | | | |
Collapse
|
46
|
Comparison of chromogenic media to BD GeneOhm methicillin-resistant Staphylococcus aureus (MRSA) PCR for detection of MRSA in nasal swabs. J Clin Microbiol 2009; 47:2281-3. [PMID: 19439540 DOI: 10.1128/jcm.02256-08] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
To select a method for detecting methicillin-resistant Staphylococcus aureus (MRSA) in nasal swabs, we compared BD GeneOhm MRSA PCR and various culture media (mannitol salt agar with cefoxitin, MRSASelect, CHROMagar MRSA, and Spectra MRSA). While PCR detection of MRSA was more rapid, MRSASelect and Spectra MRSA demonstrated performance equivalent to that of PCR with maximal detection at 24 h.
Collapse
|
47
|
Paule SM, Mehta M, Hacek DM, Gonzalzles TM, Robicsek A, Peterson LR. Chromogenic media vs real-time PCR for nasal surveillance of methicillin-resistant Staphylococcus aureus: impact on detection of MRSA-positive persons. Am J Clin Pathol 2009; 131:532-9. [PMID: 19289589 DOI: 10.1309/ajcp18onzutdugaq] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022] Open
Abstract
Surveillance for methicillin-resistant Staphylococcus aureus (MRSA) colonization can be an important element for infection control programs when managing a multidrug-resistant pathogen such as MRSA. The sensitivity and speed of laboratory testing affects the proportion of appropriate isolation days captured, which determines the success or failure of a MRSA control program. Chromogenic culture, CHROMagar MRSA (BBL, Becton Dickinson, Sparks, MD) and MRSASelect (Bio-Rad, Hercules, CA), with and without broth enrichment and real-time polymerase chain reaction (PCR; BD GeneOhm MRSA, BD Diagnostics, San Diego, CA), were compared and found to have a wide range of sensitivities (78.5%-98.2%), specificities (91.6%-100.0%), and turnaround times (2-72 hours). Real-time PCR provided the most rapid results and demonstrated the highest sensitivity followed by broth-enriched culture and then direct plating for MRSA detection in nasal swabs. There was no substantial difference in the labor required for any of the 3 approaches.
Collapse
|
48
|
A common variant of staphylococcal cassette chromosome mec type IVa in isolates from Copenhagen, Denmark, is not detected by the BD GeneOhm methicillin-resistant Staphylococcus aureus assay. J Clin Microbiol 2009; 47:1524-7. [PMID: 19297600 DOI: 10.1128/jcm.02153-08] [Citation(s) in RCA: 57] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022] Open
Abstract
Rapid tests for detection of methicillin-resistant Staphylococcus aureus (MRSA) carriage are important to limit the transmission of MRSA in the health care setting. We evaluated the performance of the BD GeneOhm MRSA real-time PCR assay using a diverse collection of MRSA isolates, mainly from Copenhagen, Denmark, but also including international isolates, e.g., USA100-1100. Pure cultures of 349 MRSA isolates representing variants of staphylococcal cassette chromosome mec (SCCmec) types I to V and 103 different staphylococcal protein A (spa) types were tested. In addition, 53 methicillin-susceptible Staphylococcus aureus isolates were included as negative controls. Forty-four MRSA isolates were undetectable; of these, 95% harbored SCCmec type IVa, and these included the most-common clone in Copenhagen, spa t024-sequence type 8-IVa. The false-negative MRSA isolates were tested with new primers (analyte-specific reagent [ASR] BD GeneOhm MRSA assay) supplied by Becton Dickinson (BD). The ASR BD GeneOhm MRSA assay detected 42 of the 44 isolates that were false negative in the BD GeneOhm MRSA assay. Combining the BD GeneOhm MRSA assay with the ASR BD GeneOhm MRSA assay greatly improved the results, with only two MRSA isolates being false negative. The BD GeneOhm MRSA assay alone is not adequate for MRSA detection in Copenhagen, Denmark, as more than one-third of our MRSA isolates would not be detected. We recommend that the BD GeneOhm MRSA assay be evaluated against the local MRSA diversity before being established as a standard assay, and due to the constant evolution of SCCmec cassettes, a continuous global surveillance is advisable in order to update the assay as necessary.
Collapse
|
49
|
Milstone AM, Song X, Beers C, Berkowitz I, Carroll KC, Perl TM. Unrecognized burden of methicillin-resistant Staphylococcus aureus and vancomycin-resistant Enterococcus carriage in the pediatric intensive care unit. Infect Control Hosp Epidemiol 2009; 29:1174-6. [PMID: 18983253 DOI: 10.1086/592093] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Routinely, children's hospitals use data from clinical cultures to estimate the burden of methicillin-resistant Staphylococcus aureus (MRSA) and vancomycin-resistant Enterococcus (VRE) carriage. In our pediatric intensive care unit, a program of weekly surveillance cultures uncovered an unrecognized reservoir of MRSA and VRE carriers. This weekly surveillance enabled more accurate estimates of the incidence rates of MRSA and VRE carriage and led to an increased number of isolation-days for patients.
Collapse
Affiliation(s)
- Aaron M Milstone
- Department of Pediatrics, Division of Pediatric Infectious Diseases, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.
| | | | | | | | | | | |
Collapse
|
50
|
Multicenter evaluation of the Cepheid Xpert methicillin-resistant Staphylococcus aureus (MRSA) test as a rapid screening method for detection of MRSA in nares. J Clin Microbiol 2009; 47:758-64. [PMID: 19129414 DOI: 10.1128/jcm.01714-08] [Citation(s) in RCA: 141] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
Abstract
The first U.S. multicenter clinical trial to assess the performance of the Cepheid Xpert MRSA assay (Xpert MRSA) was conducted. The assay is a qualitative test designed for the rapid detection of methicillin-resistant Staphylococcus aureus (MRSA) directly from nares swabs. This novel test combines integrated nucleic acid extraction and automated real-time PCR for the detection of a MRSA-specific signature sequence. A total of 1,077 nares specimens were collected from seven geographically distinct health care sites across the United States with prevalence rates ranging from 5.2% to 44%. Nares specimens were tested by (i) the Xpert MRSA assay, (ii) direct culture on CHROMagar MRSA medium (direct CM culture), and (iii) broth-enriched culture (Trypticase soy broth with 6.5% sodium chloride) followed by plating onto CHROMagar MRSA medium (broth-enriched CM culture). When direct CM culture was designated the reference method, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the Xpert MRSA assay were 94.3%, 93.2%, 73.0%, and 98.8%, respectively. When broth-enriched CM culture was used as the reference method, the clinical sensitivity, specificity, PPV, and NPV of the Xpert MRSA assay were 86.3%, 94.9%, 80.5%, and 96.6%, respectively. The BD GeneOhm MRSA (BDGO) assay was performed as a comparative molecular method. No statistical performance differences were observed between the Xpert MRSA and BDGO assays when they were compared to culture methods. From this large-scale, multicenter clinical comparison, we conclude that the Xpert MRSA assay is a simple, rapid, and accurate method for performing active surveillance for MRSA in a variety of health care populations.
Collapse
|