Wattanasombat S, Tongjai S. Easing genomic surveillance: A comprehensive performance evaluation of long-read assemblers across multi-strain mixture data of HIV-1 and Other pathogenic viruses for constructing a user-friendly bioinformatic pipeline.
F1000Res 2024;
13:556. [PMID:
38984017 PMCID:
PMC11231628 DOI:
10.12688/f1000research.149577.1]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 05/14/2024] [Indexed: 07/11/2024] Open
Abstract
Background
Determining the appropriate computational requirements and software performance is essential for efficient genomic surveillance. The lack of standardized benchmarking complicates software selection, especially with limited resources.
Methods
We developed a containerized benchmarking pipeline to evaluate seven long-read assemblers-Canu, GoldRush, MetaFlye, Strainline, HaploDMF, iGDA, and RVHaplo-for viral haplotype reconstruction, using both simulated and experimental Oxford Nanopore sequencing data of HIV-1 and other viruses. Benchmarking was conducted on three computational systems to assess each assembler's performance, utilizing QUAST and BLASTN for quality assessment.
Results
Our findings show that assembler choice significantly impacts assembly time, with CPU and memory usage having minimal effect. Assembler selection also influences the size of the contigs, with a minimum read length of 2,000 nucleotides required for quality assembly. A 4,000-nucleotide read length improves quality further. Canu was efficient among de novo assemblers but not suitable for multi-strain mixtures, while GoldRush produced only consensus assemblies. Strainline and MetaFlye were suitable for metagenomic sequencing data, with Strainline requiring high memory and MetaFlye operable on low-specification machines. Among reference-based assemblers, iGDA had high error rates, RVHaplo showed the best runtime and accuracy but became ineffective with similar sequences, and HaploDMF, utilizing machine learning, had fewer errors with a slightly longer runtime.
Conclusions
The HIV-64148 pipeline, containerized using Docker, facilitates easy deployment and offers flexibility to select from a range of assemblers to match computational systems or study requirements. This tool aids in genome assembly and provides valuable information on HIV-1 sequences, enhancing viral evolution monitoring and understanding.
Collapse