1
|
Liu J, Cai M, Yan H, Fu J, Wu G, Zhao Z, Zhao Y, Wang Y, Sun Y, You Y, Lin L, Huang J, Huang R, Zeng J. Yunnan Baiyao reduces hospital-acquired pressure ulcers via suppressing virulence gene expression and biofilm formation of Staphylococcus aureus. Int J Med Sci 2019; 16:1078-1088. [PMID: 31523169 PMCID: PMC6743274 DOI: 10.7150/ijms.33723] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/31/2019] [Accepted: 05/17/2019] [Indexed: 01/28/2023] Open
Abstract
Yunnan Baiyao (YB) as a kind of famous Chinese herbal medicine, possessed hemostatic, invigorating the circulation of blood, and anti-inflammatory effects. Identifying strategies to protect patients at risk for hospital-acquired pressure ulcers (HAPU) is essential. Herein, our results showed that YB treatment can effectively reduce the acne wound area and improve efficacy in a comparative study of 60 cases HAPU patients with S. aureus positive of acne wound pathogens. Furthermore, YB inhibited HIa expression and suppressed accessory gene regulator (agr) system controlled by regulatory RNA II and RNA III molecule using pALC1740, pALC1742 and pALC1743 S. aureus strain linked to gfpuvr reporter gene. Moreover, YB downregulated cao mRNA expression and inhibited coagulase activity by RT-PCR, slide and tube coagulase test. Additionally, YB downregulated seb, sec, sed, and tsst-1 mRNA expression to suppress enterotoxin and tsst-1 secretion and adhesion function related genes sarA, icaA, and cidA mRNA expression. Taken together, the data suggest that YB may reduce HAPU via suppressing virulence gene expression and biofilm formation of S. aureus.
Collapse
Affiliation(s)
- Jun Liu
- Laboratory of Pathogenic Biology, Guangdong Medical University, Zhanjiang 524023, China.,Dongguan Key Laboratory of Medical Bioactive Molecular Developmental and Translational Research, Guangdong Provincial Key Laboratory of Medical Molecular Diagnostics, Guangdong Medical University, Dongguan 523808, China
| | - Mufa Cai
- Department of Clinical Laboratory, Affiliated Hospital of Guangdong Medical University, Zhanjiang, Guangdong 524001, China
| | - Huimin Yan
- Dongguan Key Laboratory of Medical Bioactive Molecular Developmental and Translational Research, Guangdong Provincial Key Laboratory of Medical Molecular Diagnostics, Guangdong Medical University, Dongguan 523808, China
| | - Jiawu Fu
- Department of Neurology, Affiliated Hospital of Guangdong Medical University, Zhanjiang 524001, China
| | - Guocai Wu
- Department of Blood Internal Medicine, Affiliated Hospital of Guangdong Medical University, Zhanjiang 524001, China
| | - Zuguo Zhao
- Laboratory of Pathogenic Biology, Guangdong Medical University, Zhanjiang 524023, China
| | - Yi Zhao
- Laboratory of Pathogenic Biology, Guangdong Medical University, Zhanjiang 524023, China
| | - Yan Wang
- Laboratory of Pathogenic Biology, Guangdong Medical University, Zhanjiang 524023, China
| | - Yuanming Sun
- Guangdong Provincial Key Laboratory of Food Quality and Safety, College of Food Science, South China Agricultural University, Guangzhou 510642, China
| | - Yongke You
- School of Chinese Medicine, The University of Hongkong, Pokfulam, Hongkong
| | - Liyao Lin
- Department of Cardiothoracic Surgery, Affiliated Hospital of Guangdong Medical University, Zhanjiang, Guangdong 524001, China
| | - Juan Huang
- Dongguan Key Laboratory of Medical Bioactive Molecular Developmental and Translational Research, Guangdong Provincial Key Laboratory of Medical Molecular Diagnostics, Guangdong Medical University, Dongguan 523808, China
| | - Riming Huang
- Guangdong Provincial Key Laboratory of Food Quality and Safety, College of Food Science, South China Agricultural University, Guangzhou 510642, China
| | - Jincheng Zeng
- Dongguan Key Laboratory of Medical Bioactive Molecular Developmental and Translational Research, Guangdong Provincial Key Laboratory of Medical Molecular Diagnostics, Guangdong Medical University, Dongguan 523808, China
| |
Collapse
|
2
|
Das B, Mandal D, Dash SK, Chattopadhyay S, Tripathy S, Dolai DP, Dey SK, Roy S. Eugenol Provokes ROS-Mediated Membrane Damage-Associated Antibacterial Activity Against Clinically Isolated Multidrug-Resistant Staphylococcus aureus Strains. Infect Dis (Lond) 2016; 9:11-9. [PMID: 26917967 PMCID: PMC4756864 DOI: 10.4137/idrt.s31741] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/25/2015] [Revised: 01/11/2016] [Accepted: 01/12/2016] [Indexed: 11/06/2022] Open
Abstract
Due to the indiscriminate use of antibiotics, resistance to antibiotics has increased remarkably in Staphylococcus aureus. Vancomycin is the final drug to treat the S. aureus infection, but nowadays, resistance to this antibiotic is also increasing. So, the investigation of antibiotic resistance pattern is important. As there is already resistance to vancomycin, there is an urgent need to develop a new kind of antimicrobial to treat S. aureus infection. Eugenol may be the new drug of choice. This study was conducted to evaluate the antibacterial activity of eugenol against vancomycin-resistant S. aureus isolated from clinical pus samples. Thirty six pus samples were included in the study. Samples were isolated, identified and antimicrobial susceptibility tests were performed as per routine laboratory protocol. The antimicrobial activity and mechanisms of killing of eugenol were studied. Out of 36 pus samples, only 20 isolates were confirmed as S. aureus strains and 6 isolates exhibited vancomycin resistance. Eugenol successfully destroyed the vancomycin-resistant strains via reactive oxygen species generation and membrane damage. The prevalence of vancomycin resistance is increased day by day in different countries, and necessary steps to prevent the spread and emergence of resistance should be taken. The findings of the study suggested that eugenol might be used to treat vancomycin-resistant S. aureus.
Collapse
Affiliation(s)
- Balaram Das
- Immunology and Microbiology Laboratory, Department of Human Physiology with Community Health, Vidyasagar University, Midnapore, West Bengal, India
| | - Debasis Mandal
- Immunology and Microbiology Laboratory, Department of Human Physiology with Community Health, Vidyasagar University, Midnapore, West Bengal, India
| | - Sandeep Kumar Dash
- Immunology and Microbiology Laboratory, Department of Human Physiology with Community Health, Vidyasagar University, Midnapore, West Bengal, India
| | - Sourav Chattopadhyay
- Immunology and Microbiology Laboratory, Department of Human Physiology with Community Health, Vidyasagar University, Midnapore, West Bengal, India
| | - Satyajit Tripathy
- Immunology and Microbiology Laboratory, Department of Human Physiology with Community Health, Vidyasagar University, Midnapore, West Bengal, India
| | - Durga Pada Dolai
- Immunology and Microbiology Laboratory, Department of Human Physiology with Community Health, Vidyasagar University, Midnapore, West Bengal, India
| | - Sankar Kumar Dey
- Department of Physiology, Santal Bidroha Sardha Satabarshiki Mahavidyalaya, Goaltore, Paschim Midnapore, West Bengal, India
| | - Somenath Roy
- Immunology and Microbiology Laboratory, Department of Human Physiology with Community Health, Vidyasagar University, Midnapore, West Bengal, India
| |
Collapse
|
3
|
Automated pangenomic analysis in target selection for PCR detection and identification of bacteria by use of ssGeneFinder Webserver and its application to Salmonella enterica serovar Typhi. J Clin Microbiol 2012; 50:1905-11. [PMID: 22442318 DOI: 10.1128/jcm.06843-11] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
With the advent of high-throughput DNA sequencing, more than 4,000 bacterial genomes have been sequenced and are publicly available. We report a user-friendly web platform, ssGeneFinder Webserver (http://147.8.74.24/ssGeneFinder/), which is updated weekly for the automated pangenomic selection of specific targets for direct PCR detection and the identification of clinically important bacteria without the need of gene sequencing. To apply the ssGeneFinder Webserver for identifying specific targets for Salmonella enterica serovar Typhi, we analyzed 11 S. Typhi genomes, generated two specific targets, and validated them using 40 S. Typhi, 110 non-Typhi Salmonella serovars (serovar Paratyphi A, n = 4; Paratyphi B, n = 1; Typhimurium, n = 5; Enteritidis, n = 12; non-Paratyphi group A, n = 6; non-Paratyphi group B, n = 29; non-Paratyphi group C, n = 12; non-Typhi group D, n = 35; group E and others, n = 6), 115 Enterobacteriaceae isolates (Escherichia, n = 78; Shigella, n = 2; Klebsiella, n = 13; Enterobacter, n = 9; others, n = 13), and 66 human stool samples that were culture negative for S. Typhi. Both targets successfully detected all typical and atypical S. Typhi isolates, including an H1-j flagellin gene mutant, an aflagellated mutant which reacted with 2O Salmonella antiserum, and the Vi-negative attenuated vaccine strain Ty21a. No false positive was detected from any of the bacterial isolates and stool samples. DNA sequencing confirmed the identity of all positive amplicons. The PCR assays have detection limits as low as 100 CFU per reaction and were tested using spiked stool samples. Using a pangenomic approach, ssGeneFinder Webserver generated targets specific to S. Typhi. These and other validated targets should be applicable to the identification and direct PCR detection of bacterial pathogens from uncultured, mixed, and environmental samples.
Collapse
|
4
|
SHIMAMURA Y, MURATA M. Evaluation of Identification Methods for Staphylococcus aureus and Development of Modified Detection Methods for Staphylococcal Enterotoxin A. FOOD SCIENCE AND TECHNOLOGY RESEARCH 2009. [DOI: 10.3136/fstr.15.89] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
5
|
Fukuda S, Tatsumi H, Igarashi H, Igimi S. Rapid detection of Staphylococcus aureus using bioluminescent enzyme immunoassay. Lett Appl Microbiol 2000; 31:134-8. [PMID: 10972715 DOI: 10.1046/j.1365-2672.2000.00779.x] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
A bioluminescent enzyme immunoassay (BLEIA) method for detecting protein A-bearing Staphylococcus aureus was developed using biotinylated firefly luciferase. The BLEIA was able to detect protein A at one pg ml-1 and 103 cfu ml-1 level of Staph. aureus. The BLEIA showed significant signals with overnight cultures of all 24 Staph. aureus strains, and the BLEIA did not show any significant signals with overnight cultures of all 44 strains of coagulase-negative staphylococci and the other genus bacteria. After 5 h cultivation beginning at approximately 50 cfu ml-1, the BLEIA was able to detect all 35 Staph. aureus strains isolated from healthy humans.
Collapse
Affiliation(s)
- S Fukuda
- Research and Development Division, Kikkoman Corporation, Chiba, Japan.
| | | | | | | |
Collapse
|
6
|
Walker CWB, Brown DFJ. Identification of methicillin-resistant Staphylococcus aureus by latex agglutination kits: performance with epidemic strains (EMRSA) and strains causing problems with latex agglutination methods. Clin Microbiol Infect 1999; 5:53-56. [PMID: 11856215 DOI: 10.1111/j.1469-0691.1999.tb00100.x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Colin W. B. Walker
- Clinical Microbiology and Public Health Laboratory, Box 236, Addenbrooke's Hospital, Cambridge CB2 2QW, UK
| | | |
Collapse
|
7
|
Guardati MC, Guzmàn CA, Piatti G, Pruzzo C. Rapid methods for identification of Staphylococcus aureus when both human and animal staphylococci are tested: comparison with a new immunoenzymatic assay. J Clin Microbiol 1993; 31:1606-8. [PMID: 8315003 PMCID: PMC265586 DOI: 10.1128/jcm.31.6.1606-1608.1993] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023] Open
Abstract
A new immunoenzymatic assay (IEA) for the identification of Staphylococcus aureus strains of both human and animal origin was compared with rapid commercial kits. The sensitivities and specificities of the commercial kits varied from 90.2 to 96% and 90.8 to 93.7%, respectively. The IEA did not give any false-negative or false-positive results, while commercial kits gave high percentages of false-positive results among clumping factor-positive non-S. aureus strains. The IEA is particularly useful for isolates for which identification is doubtful, for large-scale epidemiological studies, and for identifying isolates from animals as S. aureus.
Collapse
Affiliation(s)
- M C Guardati
- Institute of Microbiology, University of Genova, Italy
| | | | | | | |
Collapse
|
8
|
Mathieu D, Picard V. Comparative evaluation of five agglutination techniques and a new miniaturized system for rapid identification of methicillin-resistant strains of Staphylococcus aureus. ZENTRALBLATT FUR BAKTERIOLOGIE : INTERNATIONAL JOURNAL OF MEDICAL MICROBIOLOGY 1991; 276:46-53. [PMID: 1789900 DOI: 10.1016/s0934-8840(11)80217-3] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
The speciation of methicillin-resistant Staphylococcus aureus (MRSA) poses a significant diagnostic problem when rapid identification methods such as slide agglutination tests, are used, because of the high proportion of false-negative reactions. 150 perfectly identified MRSA strains were tested on 5 commonly used agglutination reagents ("Bacto staph latex test", "Monostaph", "Pastorex staph", "Staphaurex", and "Staphyslide test") in comparison with a new micromethod ("RAPIDEC staph") which detects a type of staphylocoagulase within 2 hours by a fluorescence test. The "RAPIDEC staph" reagent enabled identification of all the MRSA while the agglutination tests gave poorer results: "Monostaph" correctly identified 64.6% of strains, "Staphyslide", 59.3%, "Bacto staph latex test", 44.6%, "Pastorex staph", 38.6% and "Staphaurex", 28.6%. These results show that agglutination slide tests are not reliable enough for the identification of MRSA which are more and more encountered in hospital wards. The authors recommend not to use slide agglutination methods. They suggest the tube test for coagulase which is the reference technique, although it is time-consuming and not well standardized. The results of this evaluation encourage the use of the "RAPIDEC staph" reagent since it is an easy-to-use, reliable technique for the rapid identification of Staphylococcus aureus.
Collapse
Affiliation(s)
- D Mathieu
- Service de Microbiologie, Hôpital Paul Brousse, Villejuif, France
| | | |
Collapse
|
9
|
Orsi A, Bartoloni A, Martelli L, Colao MG. Evaluation of six different agglutination methods for rapid identification of Staphylococcus aureus. Eur J Clin Microbiol Infect Dis 1989; 8:655-6. [PMID: 2506030 DOI: 10.1007/bf01968152] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
|
10
|
Fournier JM, Boutonnier A, Bouvet A. Staphylococcus aureus strains which are not identified by rapid agglutination methods are of capsular serotype 5. J Clin Microbiol 1989; 27:1372-4. [PMID: 2754004 PMCID: PMC267559 DOI: 10.1128/jcm.27.6.1372-1374.1989] [Citation(s) in RCA: 36] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023] Open
Abstract
A total of 183 recent Staphylococcus aureus clinical isolates were tested with three commercially available rapid agglutination methods. The capsular polysaccharide type and resistance to oxacillin of these isolates were also determined. Seven isolates were not identified correctly by agglutination methods. All isolates not identified by the rapid methods were of capsular serotype 5, and of these isolates, six were resistant to oxacillin. The results suggest that these agglutination kits can be improved by the use of antibodies reactive with S. aureus capsular polysaccharide.
Collapse
|
11
|
Piper J, Hadfield T, McCleskey F, Evans M, Friedstrom S, Lauderdale P, Winn R. Efficacies of rapid agglutination tests for identification of methicillin-resistant staphylococcal strains as Staphylococcus aureus. J Clin Microbiol 1988; 26:1907-9. [PMID: 3183033 PMCID: PMC266748 DOI: 10.1128/jcm.26.9.1907-1909.1988] [Citation(s) in RCA: 24] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023] Open
Abstract
Four commercially available rapid agglutination tests for the identification of Staphylococcus aureus were compared with the tube coagulase test for the identification of 300 methicillin-resistant isolates of staphylococci. Isolates tested included 207 methicillin-resistant S. aureus and 93 coagulase-negative staphylococci, collected from five medical centers. Strain variability was documented by phage typing and antimicrobial susceptibility patterns. Results of rapid identification tests ranged between 82 and 86% sensitivity, significantly poorer than the 98% sensitivity which the tube coagulase test provided.
Collapse
Affiliation(s)
- J Piper
- Division of Infectious Diseases, Wilford Hall U.S. Air Force Medical Center, Lackland Air Force Base, Texas 78236
| | | | | | | | | | | | | |
Collapse
|
12
|
Weers-Pothoff G, Moolhuijzen CE, Bongaerts GP. Comparison of seven coagulase tests for identification of Staphylococcus aureus. EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY 1987; 6:589-91. [PMID: 3436321 DOI: 10.1007/bf02014257] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
Four coagglutination tests for the identification of Staphylococcus aureus were compared with the ordinary slide and tube coagulation tests using two groups of staphylococcal strains (one isolated in the authors' laboratory and the other identified by a reference laboratory). The correct identification rate in the two groups was respectively for slide test 96.9% and 92.7%, tube coagulation (citrate plasma) 99.0% and 94.8%, tube coagulation (EDTA plasma) 99.0% and 91.7%, API Staphase III 100% and 91.7%, Staph Rapid 97.9% and 91.3%, Staphyslide 99.0% and 94.6%, Staphaurex 96.9% and 92.7%. The sensitivity of Staph Rapid, Staphyslide and Staphaurex was slightly higher than that of the other tests. These three tests and the slide test were considerably more rapid as regards identification than the other tests.
Collapse
Affiliation(s)
- G Weers-Pothoff
- Department of Medical Microbiology, University Hospital of Nijmegen, The Netherlands
| | | | | |
Collapse
|
13
|
Punsalang A, Migneault PC, Nolte FS. Reliability of latex agglutination tests for identification of Staphylococcus aureus resistant to oxacillin. J Clin Microbiol 1986; 24:1104-6. [PMID: 3640773 PMCID: PMC269109 DOI: 10.1128/jcm.24.6.1104-1106.1986] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023] Open
Abstract
Commercial latex agglutination tests (LATs) for the simultaneous detection of clumping factor and protein A are gaining increased acceptance as a means of identifying Staphylococcus aureus. We evaluated two LATs (Accu-Staph; Carr-Scarborough, Decatur, Ga.; Staphaurex; Wellcome, Dartford, England) with particular emphasis on their ability to correctly identify oxacillin-resistant S. aureus. We tested 59 oxacillin-resistant S. aureus, 136 oxacillin-susceptible S. aureus, and 92 coagulase-negative staphylococcal strains with the two LATs and with thermonuclease, slide clumping factor, tube coagulase, and protein A hemagglutination tests. Clumping factor and protein A were present in 96.9 and 82.1% of our S. aureus strains, respectively. Accu-Staph correctly identified 92.8% and Staphaurex correctly identified 91.3% of S. aureus strains. No significant difference in LAT positivity rates, presence of clumping factor, or presence of protein A was found between oxacillin-resistant and -susceptible S. aureus. Overall, there were 31 false-negative LATs for 20 S. aureus strains, 14 with Accu-Staph and 17 with Staphaurex. Ninety-five percent of these strains possessed either clumping factor or protein A or both when these factors were determined independently. There were five false-positive LATs for four strains of coagulase-negative staphylococci (three Staphylococcus epidermidis and one Staphylococcus warneri), four with Accu-Staph and one with Staphaurex. Clumping factor was present in one S. warneri strain. Thus, the specificities of Accu-Staph, Staphaurex, and the clumping factor test were 95.6, 98.9, and 98.9%, respectively. Our results indicated that LATs identify oxacillin-resistant and -susceptible S. aureus equally well; however, they offer no greater sensitivity or specificity than the clumping factor test for identification of S. aureus.
Collapse
|
14
|
Smith SM, Berezny C. Comparative evaluation of identification systems for testing methicillin-resistant strains of Staphylococcus aureus. J Clin Microbiol 1986; 24:173-6. [PMID: 3638308 PMCID: PMC268869 DOI: 10.1128/jcm.24.2.173-176.1986] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023] Open
Abstract
Several commercial systems are available to distinguish between Staphylococcus aureus and the coagulase-negative species of the Micrococcaceae family. Four latex agglutination systems (Accu-Staph, SeroSTAT, Staphaurex, and Staphylatex) and two hemagglutination systems (Hemastaph and Staphyloslide) were compared for their performance in the rapid identification of 232 isolates of staphylococci, including 114 of methicillin-resistant S. aureus. Accu-Staph, Staphaurex, and Staphyloslide correctly identified 100% of the methicillin-resistant S. aureus isolates; Hemastaph and Staphylatex, 99.1%; and SeroSTAT, 94.7%. Most reactions were easy to interpret, although 15% of the SeroSTAT reactions were weak. Autoagglutination occurred only with isolates of coagulase-negative staphylococci. False-positive reactions were rare and occurred only with systems which did not detect autoagglutination. Five of these six systems appear to be adequate for the rapid identification of S. aureus, including methicillin-resistant isolates.
Collapse
|
15
|
Berke A, Tilton RC. Evaluation of rapid coagulase methods for the identification of Staphylococcus aureus. J Clin Microbiol 1986; 23:916-9. [PMID: 3635533 PMCID: PMC268749 DOI: 10.1128/jcm.23.5.916-919.1986] [Citation(s) in RCA: 41] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023] Open
Abstract
Four rapid latex agglutination assays, StaphAurex (Wellcome Diagnostics, Research Triangle Park, N.C.), Bacto Staph (Difco Laboratories, Detroit, Mich.), SeroSTAT (Scott Laboratories, Inc., Fiskeville, R.I.), Veri-Staph (Zeus Technologies, Raritan, N.J.), and two hemagglutination tests, Staphyloslide (BBL Microbiology Systems, Cockeysville, Md.) and Hemastaph (Remel, Lenexa, Kans.), were compared with the conventional slide coagulase, tube coagulase (TC), and thermonuclease (TNase) tests for the identification of Staphylococcus aureus. A total of 118 clinical isolates of S. aureus (52 methicillin resistant), 50 S. epidermidis, 5 S. capitis, 2 S. hominis, 3 S. simulans, 6 S. saprophyticus, and 2 S. warneri were tested. The slide coagulase, TC and TNase tests detected 115 (97.5%), 117 (99.2%), and 118 (100%) of the S. aureus isolates, respectively. All showed 100% specificity. The StaphAurex, Veri-Staph, Staphyloslide, Hemastaph, SeroSTAT, and Bacto Staph assays correctly identified 117 (99.2%), 117 (99.2%), 116 (98.3%), 110 (93.2%), 108 (91.5%), and 107 (90.7%) of the S. aureus isolates, respectively. For methicillin-resistant S. aureus isolates, StaphAurex, Veri-Staph, Staphyloslide, Hemastaph, SeroSTAT, and Bacto Staph showed 1 (2%), 1 (2%), 2 (4%), 7 (13.5%), 7 (13.5%), and 8 (15.4%) false-negative results, respectively. All the commercial agglutination assays demonstrated false-positive results with strains of S. capitis, S. saprophyticus and S. warneri. The overall accuracy of the commercial agglutination assays compared with TC and TNase ranged from 90.7 to 99.2%. We recommend that negative reactions with the rapid commercial test kits for methicillin-resistant Staphylococcus isolates be confirmed with the TC or TNase test.
Collapse
|
16
|
Brown WJ. Comparison of a yellow latex reagent with other agglutination methods for the identification of Staphylococcus aureus. J Clin Microbiol 1986; 23:640-2. [PMID: 3958152 PMCID: PMC268714 DOI: 10.1128/jcm.23.3.640-642.1986] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023] Open
Abstract
A new commercial yellow latex agglutination reagent (Bacto-Staph) was compared with the slide and tube coagulase tests and three other commercial reagents for the identification of 283 Staphylococcus aureus and 54 non-S. aureus staphylococcal strains. Test sensitivities for the identification of S. aureus were as follows: tube coagulase, 99.6%; slide coagulase, 98.6%; Bacto-Staph, 99.6%; Staphylatex, 98.6%; Sero STAT Staph, 98.2%; and Staphyloslide, 97.5%. No false-positive reactions were observed with any of the commercial reagents.
Collapse
|
17
|
Baker JS, Bormann MA, Boudreau DH. Evaluation of various rapid agglutination methods for the identification of Staphylococcus aureus. J Clin Microbiol 1985; 21:726-9. [PMID: 3998102 PMCID: PMC271767 DOI: 10.1128/jcm.21.5.726-729.1985] [Citation(s) in RCA: 22] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023] Open
Abstract
A latex agglutination test (SeroSTAT Staph; Scott Laboratories, Fiskeville, R.I.) and two hemagglutination tests (Staphyloslide; BBL Microbiology Systems, Cockeysville, Md.; and Hemastaph; Remel, Lenexa, Kans.) were compared with the slide coagulase (SC) and tube coagulase (TC) tests at room temperature (22 to 25 degrees C) and at 37 degrees C for the rapid identification of Staphylococcus aureus. A total of 380 clinical strains of staphylococci were tested. The TC test performed at room temperature yielded the largest number of TC-positive results (n = 239), and based on this observation 239 organisms were classified as S. aureus and 141 were classified as non-S. aureus. The SC, TC (37 degrees C), SeroSTAT Staph, Staphyloslide, and Hemastaph tests correctly identified 210 (87.9%), 221 (92.5%), 238 (99.6%), 239 (100%), and 236 (98.7%) of the S. aureus isolates, respectively. Of the S. aureus isolates that were TC positive at room temperature 68% required 24 h of incubation before coagulase production was detected. There was one false-negative SeroSTAT Staph result and one false-negative Hemastaph result. The Staphyloslide test yielded two noninterpretable results (both organisms were later confirmed as non-S. aureus), whereas there were six noninterpretable results recorded with the Hemastaph test (four organisms were classified as non-S. aureus, and two were classified as S. aureus). The SeroSTAT Staph, Staphyloslide, and Hemastaph tests were all more sensitive than the conventional SC and TC (37 degrees C) tests and were considerably more rapid than the TC test at either temperature.
Collapse
|
18
|
|
19
|
Pennell DR, Rott-Petri JA, Kurzynski TA. Evaluation of three commercial agglutination tests for the identification of Staphylococcus aureus. J Clin Microbiol 1984; 20:614-7. [PMID: 6490847 PMCID: PMC271395 DOI: 10.1128/jcm.20.4.614-617.1984] [Citation(s) in RCA: 28] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023] Open
Abstract
Three commercially available rapid slide agglutination tests for the identification of Staphylococcus aureus were evaluated with 354 recent clinical isolates (165 strains of S. aureus). The test results of two latex agglutination products, SeroSTAT Staph (Scott Laboratories, Inc.) and Staphylatex (American Micro Scan), and one hemagglutination product, Staphyloslide (BBL Microbiology Systems), were compared with the results of the tube coagulase test, which was read at 4 h (4-h tube coagulase test) and, if negative, again after overnight incubation at room temperature (24-h tube coagulase test). Discrepancies between agglutination and tube coagulase identifications were resolved by use of the thermonuclease, mannitol fermentation, and slide coagulase tests. All sensitivities, specificities, predictive values of a positive result, and predictive values of a negative result for the three agglutination tests were at least 98.8% and comparable with the 4-h tube coagulase test. Best results were obtained with the 24-h tube coagulase test, which yielded one false-negative and no false-positive tests. Agglutination identifications may be performed on organisms taken directly from a primary plate when sufficient growth is present. Kit agglutination procedures yield rapid and reliable identifications and are easy to perform. This study also demonstrates the usefulness of the 24-h tube coagulase test.
Collapse
|
20
|
Pourshadi M, Klaas J. Evaluation of latex agglutination and microtube coagulase tests for detection of Staphylococcus aureus. Diagn Microbiol Infect Dis 1984; 2:287-91. [PMID: 6488745 DOI: 10.1016/0732-8893(84)90059-2] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
In a blind study, a latex agglutination test (Serostat Staphylococcus, Scott Laboratories) and a microtube coagulase test (Staphase, API) were evaluated for their ability to detect Staphylococcus aureus. Of 289 isolates of catalase-positive, gram-positive cocci, 122 were identified as S. aureus based on positive reactions in at least three of the following tests: tube coagulase, slide coagulase, DNase production, or anaerobic fermentation of mannitol. The latex agglutination test gave positive reactions for all S. aureus isolates and 10 (6%) non-S. aureus isolates. The slide coagulase test was positive for 121 S. aureus isolates and three (2%) non-S. aureus isolates. The microtube coagulase test detected 53, 90, and 98% of the S. aureus isolates after 2, 4, and 24 hr, respectively. In contrast, the conventional tube coagulase test detected 97% of the S. aureus isolates after 2 hr, and 98% after 4 and 24 hr. Two isolates of S. aureus gave negative tube coagulase reactions at 37 degrees C, but positive reactions at room temperature after 24 hr. The combination of tube and slide coagulase tests provided the most reliable results. The slide and tube coagulase tests gave more reliable results than the latex agglutination and microtube coagulase tests, respectively.
Collapse
|
21
|
Aldridge KE, Kogos C, Sanders CV, Marier RL. Comparison of rapid identification assays for Staphylococcus aureus. J Clin Microbiol 1984; 19:703-4. [PMID: 6376540 PMCID: PMC271159 DOI: 10.1128/jcm.19.5.703-704.1984] [Citation(s) in RCA: 29] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023] Open
Abstract
A total of 137 strains of Staphylococcus species were blindly tested by four rapid serological assays, and the results were compared with those of the tube coagulase assay. For the S. aureus isolates, the Sero-STAT Staph assay gave six false-negative results, four of which were for methicillin-resistant strains. The Accu -Staph, Staphylatex , and Staphyloslide assays identified all the coagulase-positive strains as Staphylococcus aureus. Among the coagulase-negative staphylococci, false-positive results were seen with strains of S. capitis. S. saprophyticus, and S. cohnii. The overall accuracy of the kits compared with the tube coagulase test ranged from 95.1 to 100%.
Collapse
|
22
|
Jasper DE, Martinez FI, Dellinger JD. Evaluation of latex agglutination tests for establishing coagulase status of staphylococci from milk. CANADIAN JOURNAL OF COMPARATIVE MEDICINE : REVUE CANADIENNE DE MEDECINE COMPAREE 1984; 48:223-224. [PMID: 6722649 PMCID: PMC1236043] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
A total number of 640 staphylococci isolated from cows' milk were tested by latex agglutination and coagulase tests. About 50% of coagulase positive and 5% of coagulase negative staphylococci were positive to the latex agglutination tests. Latex agglutination tests were found to be not satisfactory for determining the coagulase status of staphylococci isolated from cows' milk.
Collapse
|
23
|
Jungkind DL, Torhan NJ, Corman KE, Bondi JM. Comparison of two commercially available test methods with conventional coagulase tests for identification of Staphylococcus aureus. J Clin Microbiol 1984; 19:191-3. [PMID: 6365958 PMCID: PMC271015 DOI: 10.1128/jcm.19.2.191-193.1984] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023] Open
Abstract
The API STAPHase (Analytab Products, Inc., Plainview, N.Y.) and SeroSTAT Staph (Scott Laboratories, Fiskville, R.I.) tests were compared to the conventional tube coagulase test and a slide coagulase test by using fresh isolates of members of the family Micrococcaceae. The 4-h, 24-h, and combined readings of the tube coagulase test detected 94.5, 99.5 and 100%, respectively, of 219 Staphylococcus aureus isolates. The API STAPHase, SeroSTAT Staph, and slide coagulase tests detected 95.9, 95.4 and 95.9% of the isolates of S. aureus, respectively. There were no false-positive results with any of the systems when tested with 103 strains of members of the family Micrococcaceae other than S. aureus. We concluded that the STAPHase and SeroSTAT Staph tests were equal in accuracy to the slide coagulase and 4-h tube coagulase tests and were suitable for use in the clinical microbiology laboratory. However, SeroSTAT Staph gave faster results than the API STAPHase, and the test was easier to perform. Also, the false-negative rate was high enough with the STAPHase, SeroSTAT Staph, and the slide coagulase tests that all negative reactions should be confirmed with a tube test.
Collapse
|
24
|
Dibb WL, Hellum KB, Ostervold B, Oeding P. Comparison of four methods for differentiation of Staphylococcus aureus from other Micrococcaceae in the routine laboratory. ACTA PATHOLOGICA, MICROBIOLOGICA, ET IMMUNOLOGICA SCANDINAVICA. SECTION B, MICROBIOLOGY 1983; 91:307-10. [PMID: 6362324 DOI: 10.1111/j.1699-0463.1983.tb00051.x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
Four methods for the identification of Staphylococcus aureus (tube coagulase test, thermostable nuclease test, indirect agglutination of fibrinogen coated erythrocytes and a commercial latex kit: SeroSTAT Staphylococcus Test) have been compared. Clinical isolates (698) and 40 reference strains of Micrococcaceae were included in the study together with control organisms. The coagulase test gave no false positive results but 39/406 clinical isolates of S. aureus were negative at 2h and one half were only weakly positive. At 18 h, all but 2 of 406 isolates gave a positive reaction. The thermostable nuclease test was very specific; no clinical isolates of S. aureus gave negative results and no "coagulase-negative" clinical isolates gave a definite positive reaction. The indirect haemagglutination method was sometimes difficult to interpret and frequently gave negative or doubtful results for S. aureus. The SeroSTAT test was easy to use and interpret and was specific; the method is suitable for routine laboratory use, particularly when a rapid result is desirable.
Collapse
|
25
|
Doern GV, Earls JE, Jeznach PA, Parker DS. Species identification and biotyping of staphylococci by the API staph-ident system. J Clin Microbiol 1983; 17:260-3. [PMID: 6339546 PMCID: PMC272618 DOI: 10.1128/jcm.17.2.260-263.1983] [Citation(s) in RCA: 22] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023] Open
Abstract
The API Staph-Ident system, a commercially available biochemical and chromogenic substrate micromethod, was evaluated as a means for identifying the species and determining the biotypes of human strains of staphylococci routinely encountered in a clinical microbiology laboratory. The species identity of 152 of 188 (80.9%) unique clinical isolates of staphylococci was correctly predicted by this method after 5 h of incubation according to the recommendations of the manufacturer. When results were determined after 24 h of incubation, the overall accuracy of this procedure was 90.4%. The API Staph-Ident system was not an adequate procedure for assessing strain biotypes since the patterns of biochemical reactivity observed with 53 of 54 (98.2%) unique isolates of Staphylococcus aureus were identical. Similarly, 58 of 62 (93.6%) different strains of S. epidermidis yielded the same biochemical profile.
Collapse
|
26
|
Doern GV, Robbie LI. Direct identification of Staphylococcus aureus in blood culture fluid with a commercial latex agglutination test. J Clin Microbiol 1982; 16:1048-51. [PMID: 6761357 PMCID: PMC272537 DOI: 10.1128/jcm.16.6.1048-1051.1982] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023] Open
Abstract
A commercial latex agglutination slide test (SeroSTAT Staph, Scott Laboratories, Inc., Fiskeville, R.I.) accurately identified Staphylococcus aureus when applied directly to blood culture fluid containing staphylococci. This latex agglutination test exhibited 100% accuracy when 30 seeded aerobic and anaerobic radiometric blood cultures (15 strains of S. aureus, 15 strains of other staphylococcal species) were tested blindly. In 36 actual clinical specimens yielding 16 isolates of S. aureus and 20 isolates of Staphylococcus epidermidis, 94.4% accuracy was achieved. The latex agglutination test provided positive test results before objective criteria of blood culture positivity such as radiometric growth indices and Gram stains became positive.
Collapse
|