1
|
Kakino A, Pattanawong U, Kuamsab N, Imai T, Putaporntip C, Asai S, Cheng X, Jongwutiwes S, Tachibana H. Usefulness of a new immunochromatographic assay using fluorescent silica nanoparticles for serodiagnosis of Thai patients with amebiasis. Drug Discov Ther 2024; 18:10-15. [PMID: 38355121 DOI: 10.5582/ddt.2023.01102] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/16/2024]
Abstract
A fluorescence immunochromatography (FIC) kit was developed recently using fluorescent silica nanoparticles coated with a recombinant C-terminal fragment of the surface lectin intermediate subunit (C-Igl) of Entamoeba histolytica to establish rapid serodiagnosis of amebiasis. We further evaluated the system using serum samples from 52 Thai patients with amebiasis. Of the patients, 50 (96%) tested positive using FIC. The samples were also tested using enzyme-linked immunosorbent assay (ELISA) with C-Igl as the antigen. Two samples were negative on ELISA but positive on FIC. The correlation coefficient between the fluorescence intensity using FIC and the optical density value using ELISA was 0.5390, indicating a moderate correlation between the two tests. Serum samples from 20 patients with malaria and 22 patients with Clostridioides difficile infection were also tested using FIC. The false-positive rates were 4/20 (20%) and 1/22 (4%) in patients with malaria and C. difficile infection, respectively. Combining the data from the present study with our previous study, the sensitivity and specificity of FIC were determined to be 98.5% and 95.2%, respectively. The results of the 50 samples were studied using a fluorescence scope and a fluorescence intensity reader, and the findings were compared. Disagreements were found in only two samples showing near-borderline fluorescence intensity, indicating that the use of scope was adequate for judging the results. These results demonstrate that FIC is a simple and rapid test for the serodiagnosis of amebiasis.
Collapse
Affiliation(s)
- Azumi Kakino
- Department of Parasitology, Tokai University School of Medicine, Isehara, Japan
| | - Urassaya Pattanawong
- Department of Parasitology, Tokai University School of Medicine, Isehara, Japan
- Molecular Biology of Malaria and Opportunistic Parasites Research Unit, Department of Parasitology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand
| | - Napaporn Kuamsab
- Department of Parasitology, Tokai University School of Medicine, Isehara, Japan
- Molecular Biology of Malaria and Opportunistic Parasites Research Unit, Department of Parasitology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand
- Community Public Health Program, Faculty of Health Science and Technology, Southern College of Technology, Nakorn Si Thammarat, Thailand
| | - Tatsuya Imai
- Department of Parasitology, Tokai University School of Medicine, Isehara, Japan
| | - Chaturong Putaporntip
- Molecular Biology of Malaria and Opportunistic Parasites Research Unit, Department of Parasitology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand
| | - Satomi Asai
- Department of Laboratory Medicine, Tokai University School of Medicine, Isehara, Japan
| | - Xunjia Cheng
- Department of Parasitology, Tokai University School of Medicine, Isehara, Japan
- Department of Medical Microbiology and Parasitology, School of Basic Medical Sciences, Fudan University, Shanghai, China
| | - Somchai Jongwutiwes
- Molecular Biology of Malaria and Opportunistic Parasites Research Unit, Department of Parasitology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand
| | - Hiroshi Tachibana
- Department of Parasitology, Tokai University School of Medicine, Isehara, Japan
| |
Collapse
|
2
|
Noordin R, Yunus MH, Saidin S, Mohamed Z, Fuentes Corripio I, Rubio JM, Golkar M, Hisam S, Lee R, Mahmud R. Multi-Laboratory Evaluation of a Lateral Flow Rapid Test for Detection of Amebic Liver Abscess. Am J Trop Med Hyg 2020; 103:2233-2238. [PMID: 32996457 DOI: 10.4269/ajtmh.20-0348] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022] Open
Abstract
Independent evaluations of XEh Rapid®, an IgG4-based rapid dipstick test, were performed to assess its diagnostic performance to detect amebic liver abscess (ALA) using 405 samples at seven laboratories in four countries. The test showed high diagnostic specificity (97-100%) when tested with samples from healthy individuals (n = 100) and patients with other diseases (n = 151). The diagnostic sensitivity was tested with a total of 154 samples, and the results were variable. It was high in three laboratories (89-94%), and moderate (72%) and low (38%) in two other laboratories. Challenges and issues faced in the evaluation process are discussed. Nevertheless, XEh Rapid is promising to be developed into a point-of-care test in particular for resource-limited settings, and thus merits further confirmation of its diagnostic sensitivity.
Collapse
Affiliation(s)
- Rahmah Noordin
- Institute for Research in Molecular Medicine (INFORMM), Universiti Sains Malaysia, Penang, Malaysia
| | - Muhammad Hafiznur Yunus
- Institute for Research in Molecular Medicine (INFORMM), Universiti Sains Malaysia, Penang, Malaysia
| | - Syazwan Saidin
- Department of Biology, Faculty of Science and Mathematics, Universiti Pendidikan Sultan Idris, Perak, Malaysia.,Institute for Research in Molecular Medicine (INFORMM), Universiti Sains Malaysia, Penang, Malaysia
| | - Zeehaida Mohamed
- Department of Medical Microbiology and Parasitology, School of Medical Sciences, Universiti Sains Malaysia, Kelantan, Malaysia
| | - Isabel Fuentes Corripio
- Parasitology Department, National Microbiology Centre, Instituto de Salud Carlos III, Madrid, Spain
| | - José Miguel Rubio
- Parasitology Department, National Microbiology Centre, Instituto de Salud Carlos III, Madrid, Spain
| | - Majid Golkar
- Parasitology Department, Pasteur Institute of Iran, Tehran, Iran
| | - Shamilah Hisam
- Parasitology Unit, Institute for Medical Research, NIH Complex Setia Alam, MOH Malaysia, Selangor, Malaysia
| | - Rogan Lee
- NSW Health Pathology, Centre for Infectious Disease and Microbiology Laboratory Services, Westmead Hospital, Westmead, Australia
| | - Rohela Mahmud
- Department of Parasitology, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia
| |
Collapse
|
3
|
Saidin S, Othman N, Noordin R. Update on laboratory diagnosis of amoebiasis. Eur J Clin Microbiol Infect Dis 2018; 38:15-38. [DOI: 10.1007/s10096-018-3379-3] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2018] [Accepted: 09/07/2018] [Indexed: 02/06/2023]
|
4
|
Development of a sensitive immunochromatographic kit using fluorescent silica nanoparticles for rapid serodiagnosis of amebiasis. Parasitology 2018; 145:1890-1895. [PMID: 29739480 DOI: 10.1017/s0031182018000690] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
We have previously shown that the C-terminal region of the intermediate subunit of Entamoeba histolytica galactose- and N-acetyl-D-galactosamine-inhibitable lectin (C-Igl) is a useful antigen for serodiagnosis of amebiasis. An immunochromatographic kit was developed using fluorescent silica nanoparticles coated with C-Igl prepared in Escherichia coli. Samples for examination were added to the freeze-dried particles and then applied to the immunochromatographic device, in which a test line on the membrane was also coated with C-Igl. Fluorescent intensity was measured using a hand-held reader. In an evaluation of the kit using a human monoclonal antibody, the minimum amount of C-Igl specific antibody showing positive results was 100 pg. In the evaluation of serum samples with different antibody titers in indirect immunofluorescent antibody tests in the kit, 20 µL of serum was sufficient to obtain positive results at 30 min. Serum samples from symptomatic patients with amebic colitis and amebic liver abscess and those from asymptomatic E. histolytica-cyst carriers showed positive results in the kit. Based on evaluation using sera from healthy controls and patients with other infectious diseases, the sensitivity and specificity of the kit were 100 and 97.6%, respectively. Therefore, we conclude that the newly developed kit is useful for rapid serodiagnosis of amebiasis.
Collapse
|
5
|
Dhanalakshmi S, Meenachi C, Parija SC. Indirect Haemagglutination Test in Comparison with ELISA for Detection of Antibodies against Invasive Amoebiasis. J Clin Diagn Res 2016; 10:DC05-8. [PMID: 27656436 DOI: 10.7860/jcdr/2016/21566.8326] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2016] [Accepted: 07/19/2016] [Indexed: 11/24/2022]
Abstract
INTRODUCTION Diagnosis of amoebiasis is based on combination of tests like microscopy, imaging, serology and molecular methods. In absence of molecular techniques, serology can be used as an alternative aid. Various serological techniques were reported with different sensitivity and specificity. The diagnostic efficiency of these assays mainly depends on the characteristics of antigen that is being used and various conditions of performance. AIM To evaluate the efficiency of recombinant calcium binding domain containing protein by Indirect Haemagglutination Assay (IHA) against a commercial ELISA among amoebic liver abscess cases and control group. MATERIALS AND METHODS The study was carried out during the period of 2011-2015 and blood samples were collected from suspected amoebiasis cases who were attending the clinics of Medicine and Paediatrics department, JIPMER. A total of 200 sera samples which included 100 Amoebic Liver Abscess (ALA), 50 cases of other parasitic infections and liver diseases and 50 presumed healthy controls were examined by IHA and commercial ELISA. In brief, chick cells were stabilized by Double Aldehyde Sensitization (DAS) method. Optimum Sensitizing Dose (OSD) of the antigen was determined. The test was performed in a U-bottomed microtiter plate with recombinant amoebic antigen (12.5μg/ml), incubated at Room Temperature (RT) for 2 hours. RIDASCREEN Entamoeba IgG ELISA kit which is commercially available was used to evaluate the samples as per manufacturer's instruction. RESULTS The overall sensitivity and specificity of the IHA was 62% and 96%, respectively when compared to ELISA having sensitivity and specificity of 69% and 90%, respectively. The positive predictive value of the IHA was 91% while negative predictive value was 79%. Similarly, the positive predictive value of the ELISA was 87% while negative predictive value was 74%. CONCLUSION As serology heavily suffers due to lack of a standardised test system employing the native antigen, there arises need to identify alternative source of recombinant antigen which could effectively improvise the existing lacunae in the current system. Serology acts as an adjunct in clinical decision making if properly interpreted. This is an important consideration in endemic region where health services resources are limited.
Collapse
Affiliation(s)
- Sankaramoorthy Dhanalakshmi
- Ph.D Scholar, Department of Microbiology, Jawaharlal Institute of Postgraduate Medical Education and Research , Puducherry, Tamil Nadu, India
| | - Chidambaram Meenachi
- Junior Resident, Department of Microbiology, Jawaharlal Institute of Postgraduate Medical Education and Research , Puducherry, Tamil Nadu, India
| | - Subhash Chandra Parija
- Director and Senior Professor of Microbiology, Jawaharlal Institute of Postgraduate Medical Education and Research , Puducherry, Tamil Nadu, India
| |
Collapse
|
6
|
Ning TZ, Kin WW, Noordin R, Cun STW, Chong FP, Mohamed Z, Olivos-Garcia A, Huat LB. Evaluation of Entamoeba histolytica recombinant phosphoglucomutase protein for serodiagnosis of amoebic liver abscess. BMC Infect Dis 2013; 13:144. [PMID: 23514636 PMCID: PMC3606622 DOI: 10.1186/1471-2334-13-144] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2012] [Accepted: 03/13/2013] [Indexed: 12/03/2022] Open
Abstract
Background Amoebic liver abscess (ALA) is the most frequent clinical presentation of extra-intestinal amoebiasis. The diagnosis of ALA is typically based on the developing clinical symptoms, characteristic changes on radiological imaging and serology. Numerous serological tests have been introduced for the diagnosis of ALA, either detecting circulating amoebic antigens or antibodies. However those tests show some pitfalls in their efficacy and/or the preparation of the tests are costly and tedious. The commercial IHA kit that used crude antigen was reported to be useful in diagnosis of ALA, however high antibody background in endemic areas may cause problems in its interpretation. Thus, discovery of well-defined antigen(s) is urgently needed to improve the weaknesses of current serodiagnostic tests. Methods Crude antigen of E. histolytica was analysed by 2-DE and Western blot to identify a protein of diagnostic potential for ALA. The corresponding gene of the antigenic protein was then cloned, expressed and the purified recombinant protein was subsequently evaluated for serodiagnosis of ALA in an indirect ELISA format. Results Analysis of crude antigen showed that phosphoglucomutase (PGM) has the diagnostic potential. Recombinant PGM (rPGM) showed 79.17% (19/24) sensitivity and 86.67% (195/225) specificity in diagnosis of ALA based on the COV of mean +1SD. There was no significant difference between rPGM-ELISA and IHA diagnostic kit in the diagnosis of ALA in terms of sensitivity and specificity at p-value < 0.05. Conclusion In conclusion, rPGM-ELISA is found to be useful for serodiagnosis of ALA. Future studies will determine whether rPGM-ELISA also detects antibodies produced in amoebic dysentery and asymptomatic cases.
Collapse
Affiliation(s)
- Tan Zi Ning
- School of Health Sciences, Universiti Sains Malaysia, Kubang Kerian, Kelantan 16150, Malaysia
| | | | | | | | | | | | | | | |
Collapse
|
7
|
Schmidt RC, Healy KE. Effect of avidin-like proteins and biotin modification on mesenchymal stem cell adhesion. Biomaterials 2013; 34:3758-62. [PMID: 23452388 DOI: 10.1016/j.biomaterials.2013.01.081] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2012] [Accepted: 01/24/2013] [Indexed: 12/25/2022]
Abstract
The avidin-biotin system is a highly specific reaction that has been used in a wide range of biomedical applications, including surface modification and cell patterning. We systematically examined a number of avidin derivatives as the basis for a simple and cost effective tissue culture polystyrene substrate surface modification for human stem cell culture. Non-specific adhesion between human mesenchymal stem cells and various avidin derivatives, media conditions, and subsequent biotinylation reactions was quantified. We observed significant non-specific cell adhesion to avidin and strepthavidin, indicating that previous observations using this system may be artifactual. Seeding of cells in serum free media, blocking with bovine serum albumin, and the use of the avidin derivative neutravidin were all necessary for elimination of background adhesion. Neutravidin conjugated with biotinylated bsp-RGD(15) peptide provided the most robust cell adhesion, as well as the greatest increase in cell adhesion over background levels.
Collapse
Affiliation(s)
- Ray C Schmidt
- Department of Bioengineering, University of California at Berkeley, Berkeley, CA, USA
| | | |
Collapse
|
8
|
Yang B, Chen Y, Wu L, Xu L, Tachibana H, Cheng X. Seroprevalence of Entamoeba histolytica infection in China. Am J Trop Med Hyg 2012; 87:97-103. [PMID: 22764298 PMCID: PMC3391064 DOI: 10.4269/ajtmh.2012.11-0626] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2011] [Accepted: 04/14/2012] [Indexed: 12/23/2022] Open
Abstract
The seroprevalence of Entamoeba histolytica infection in the residents of seven provinces in China was examined by using an enzyme-linked immunosorbent assay with a crude antigen and a recombinant surface antigen, C-Igl, of the parasites. A total of 1,312 serum samples were investigated. The positivity rates for these two antigens were 11.05% and 6.25%, respectively. There was no significant difference in the seropositivity to E. histolytica between men and women. We used a logistic regression model and maximal-likelihood methods to estimate the prevalence of E. histolytica infection from sequential serologic data. Seropositivity in Sichuan, Guizhou, and Sinkiang Provinces was higher than that in Beijing, Shanghai, and Qinghai Provinces. The present study provides an overview of seropositivity to E. histolytica infection in seven provinces in China and use the logistic regression model estimation method to achieve a more accurate measure of amebiasis prevalence.
Collapse
Affiliation(s)
- Bin Yang
- Department of Microbiology and Parasitology, Shanghai Medical College, Fudan University, Shanghai, China.
| | | | | | | | | | | |
Collapse
|
9
|
Fotedar R, Stark D, Beebe N, Marriott D, Ellis J, Harkness J. Laboratory diagnostic techniques for Entamoeba species. Clin Microbiol Rev 2007; 20:511-32, table of contents. [PMID: 17630338 PMCID: PMC1932757 DOI: 10.1128/cmr.00004-07] [Citation(s) in RCA: 251] [Impact Index Per Article: 14.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
The genus Entamoeba contains many species, six of which (Entamoeba histolytica, Entamoeba dispar, Entamoeba moshkovskii, Entamoeba polecki, Entamoeba coli, and Entamoeba hartmanni) reside in the human intestinal lumen. Entamoeba histolytica is the causative agent of amebiasis and is considered a leading parasitic cause of death worldwide in humans. Although recent studies highlight the recovery of E. dispar and E. moshkovskii from patients with gastrointestinal symptoms, there is still no convincing evidence of a causal link between the presence of these two species and the symptoms of the host. New approaches to the identification of E. histolytica are based on detection of E. histolytica-specific antigen and DNA in stool and other clinical samples. Several molecular diagnostic tests, including conventional and real-time PCR, have been developed for the detection and differentiation of E. histolytica, E. dispar, and E. moshkovskii in clinical samples. The purpose of this review is to discuss different methods that exist for the identification of E. histolytica, E. dispar, and E. moshkovskii which are available to the clinical diagnostic laboratory. To address the need for a specific diagnostic test for amebiasis, a substantial amount of work has been carried out over the last decade in different parts of the world. The molecular diagnostic tests are increasingly being used for both clinical and research purposes. In order to minimize undue treatment of individuals infected with other species of Entamoeba such as E. dispar and E. moshkovskii, efforts have been made for specific diagnosis of E. histolytica infection and not to treat based simply on the microscopic examination of Entamoeba species in the stool. The incorporation of many new technologies into the diagnostic laboratory will lead to a better understanding of the public health problem and measures to control the disease.
Collapse
Affiliation(s)
- R Fotedar
- St. Vincent's Hospital, Department of Microbiology, Sydney, Darlinghurst, NSW 2010, Australia
| | | | | | | | | | | |
Collapse
|
10
|
Knappik M, Börner U, Jelinek T. Sensitivity and specificity of a new commercial enzyme-linked immunoassay kit for detecting Entamoeba histolytica IgG antibodies in serum samples. Eur J Clin Microbiol Infect Dis 2006; 24:701-3. [PMID: 16261304 DOI: 10.1007/s10096-005-0030-x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
The study presented here was conducted to evaluate the performance of the newly available RIDASCREEN Set (R-Biopharm AG, Darmstadt, Germany) for the detection of immunoglobulin G antibodies against Entamoeba histolytica. The sensitivity and specificity of this new enzyme-linked immunosorbent assay were evaluated using a panel of sera from 239 individuals. The assay was positive for 43 of 44 patients with invasive amebiasis, including all 18 patients with amebic liver abscess, while it was negative for 190 of 195 adult controls who were either healthy individuals or patients with other parasitic diseases. The kit was found to be highly specific (97.4%) and sensitive (97.7%) for detecting antibodies against E. histolytica in humans. Although antibody titers in patients with amebic liver abscess tend to be higher on average than in patients with invasive amebiasis, it is not possible to distinguish the two forms solely based on the results of this commercial test.
Collapse
Affiliation(s)
- M Knappik
- Berlin Institute of Tropical Medicine, Spandauer Damm 130, 14050, Berlin, Germany
| | | | | |
Collapse
|
11
|
Kjos SA, Jenkins M, Okhuysen PC, Chappell CL. Evaluation of recombinant oocyst protein CP41 for detection of cryptosporidium-specific antibodies. CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY 2005; 12:268-72. [PMID: 15699421 PMCID: PMC549316 DOI: 10.1128/cdli.12.2.268-272.2005] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/12/2004] [Revised: 11/12/2004] [Accepted: 12/13/2004] [Indexed: 11/20/2022]
Abstract
Cryptosporidium is an important cause of diarrhea in developed and developing countries, and its epidemiology is of interest. The methodologies used in the detection of Cryptosporidium-specific antibodies vary widely, which complicates comparison of results. This study assesses the performance of a Cryptosporidium recombinant protein (rCP41) in a serological assay compared to that of a crude antigen preparation. The 41-kDa protein from the oocyst wall was previously cloned and expressed in Escherichia coli. Sera from 192 healthy adults from the Texas Medical Center (Houston) were tested for anti-Cryptosporidium antibody reactivity using both crude and recombinant antigen preparations in an enzyme-linked immunosorbent assay. Immunoglobulin G reactivity was highly concordant (88%; P < 0.0001) between the two antigen preparations, with 110 positive (57%) and 59 negative (31%) by both tests. Regression analysis revealed a high correlation between the absorbance values generated with both antigen preparations and suggests that the rCP41 may be used in place of crude antigen. These results indicate that the use of the recombinant CP41 antigen in a standardized serodiagnostic assay could provide a reliable and cost-effective method for assessing human exposure to Cryptosporidium.
Collapse
Affiliation(s)
- Sonia A Kjos
- Center for Infectious Diseases, The University of Texas Health Science Center School of Public Health, Houston, TX 77030, USA
| | | | | | | |
Collapse
|
12
|
Tachibana H, Cheng XJ, Masuda G, Horiki N, Takeuchi T. Evaluation of recombinant fragments of Entamoeba histolytica Gal/GalNAc lectin intermediate subunit for serodiagnosis of amebiasis. J Clin Microbiol 2004; 42:1069-74. [PMID: 15004055 PMCID: PMC356887 DOI: 10.1128/jcm.42.3.1069-1074.2004] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
We have recently identified a 150-kDa surface antigen of Entamoeba histolytica as an intermediate subunit (Igl) of galactose- and N-acetyl-D-galactosamine-inhibitable lectin, which is a cysteine-rich protein consisting of 1,101 amino acids (aa) and containing multiple CXXC motifs in amino acid sequences. In the present study, full-length Igl except for the signal sequences (aa 14 to 1088) and three fragments of Igl-the N-terminal part (aa 14 to 382), the middle part (aa 294 to 753), and the C-terminal part (aa 603 to 1088)-were prepared in Escherichia coli, and the reactivity of these recombinant proteins with sera from patients with amebiasis was examined by means of enzyme-linked immunosorbent assay (ELISA). Sera from 57 symptomatic patients with amebic liver abscess or amebic colitis, sera from 15 asymptomatic cyst passers, sera from 40 individuals with other protozoan infections, and sera from 50 healthy controls were used. The sensitivity and specificity of the recombinant full-length Igl in the ELISA were 90 and 94%, respectively. When three fragments were used as antigens in the ELISA, the sensitivities were 56% in the N terminus, 92% in the middle part, and 97% in the C terminus. The specificities of the three antigens were 96% in the N terminus and 99% in both the middle and C-terminal fragments. These results demonstrate that Igl is well recognized in not only symptomatic but also asymptomatic patients with E. histolytica infection and that the carboxyl terminus of Igl is an especially useful antigen for the serodiagnosis of amebiasis.
Collapse
Affiliation(s)
- Hiroshi Tachibana
- Department of Infectious Diseases, Tokai University School of Medicine, Isehara, Kanagawa, Japan.
| | | | | | | | | |
Collapse
|
13
|
Abstract
The detection of Entamoeba histolytica, the causative agent of amebiasis, is an important goal of the clinical microbiology laboratory. To assess the scope of E. histolytica infection, it is necessary to utilize accurate diagnostic tools. As more is discovered about the molecular and cell biology of E. histolytica, there is great potential for further understanding the pathogenesis of amebiasis. Molecular biology-based diagnosis may become the technique of choice in the future because establishment of these protozoa in culture is still not a routine clinical laboratory process. In all cases, combination of serologic tests with detection of the parasite (by antigen detection or PCR) offers the best approach to diagnosis, while PCR techniques remain impractical in many developing country settings. The detection of amebic markers in serum in patients with amebic colitis and liver abscess appears promising but is still only a research tool. On the other hand, stool antigen detection tests offer a practical, sensitive, and specific way for the clinical laboratory to detect intestinal E. histolytica. All the current tests suffer from the fact that the antigens detected are denatured by fixation of the stool specimen, limiting testing to fresh or frozen samples.
Collapse
Affiliation(s)
- Mehmet Tanyuksel
- Department of Microbiology and Clinical Microbiology, Gulhane Military Medical Academy, Etlik, Ankara 06018, Turkey
| | | |
Collapse
|
14
|
Takakura A, Goto K, Itoh T, Yoshimatsu K, Takashima I, Arikawa J. Establishment of an enzyme-linked immunosorbent assay for detection of hantavirus antibody of rats using a recombinant of nucleocapsid protein expressed in Escherichia coli. Exp Anim 2003; 52:25-30. [PMID: 12638233 DOI: 10.1538/expanim.52.25] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022] Open
Abstract
A recombinant nucleocapsid protein of Hantaan virus (HTN) 76-118 strain expressed in E. coli was applied as a serodiagnostic antigen in an enzyme-linked immunosorbent assay (rHTN-ELISA) for detection of hantavirus antibody in rat sera. The sensitivity and specificity of the rHTN-ELISA were compared with those of the indirect immunofluoresent assay (IFA) using virus-infected cells. The sensitivity of rHTN-ELISA was similar to that of the IFA both in experimentally SR-11 infected rat and naturally infected rat sera. Sera showing a low antibody titer in IFA and suspected to be negative by other methods were also found to be negative in rHTN-ELISA. These results indicate that rHTN-ELISA is effective as a screening method for serodiagnosis of hantaviruses, because of its high sensitivity, specificity, safety and suitability for processing large number of samples.
Collapse
Affiliation(s)
- Akira Takakura
- Central Institute for Experimental Animals, 1430 Nogawa, Miyamae, Kawasaki, 216-0001, Japan
| | | | | | | | | | | |
Collapse
|
15
|
Kikuchi T, Furuta T, Kojima S. Kinetics of the nucleoside triphosphate hydrolase of Toxoplasma gondii in mice with acute and chronic toxoplasmosis. ANNALS OF TROPICAL MEDICINE AND PARASITOLOGY 2002; 96:35-41. [PMID: 11989532 DOI: 10.1179/000349802125000493] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
The kinetics of the nucleoside triphosphate hydrolase (NTPase) of Toxoplasma gondii was examined using an avidin-biotin sandwich-ELISA (ABS-ELISA) based on an anti-NTPase monoclonal antibody, 6C6. The RH and ME49 strains of the parasite were used to produce acute and chronic infections in mice, respectively. In the acute model, detectable serum concentrations of NTPase were observed from day 1 post-infection and gradually increased until the death of the mice. They were associated with parasitaemia (as estimated by bioassay). No anti-T. gondii antibody could be detected at any time. In the chronic model, in which 20 T. gondii ME49 cysts were given to each mouse per os, the NTPase concentration generally increased from day 3, peaked between days 7 and 14 and then declined. However, one of the four mice used still had a high serum concentration of NTPase on day 35. Again, detectable NTPase concentrations occurred when the mice had parasitaemias. Antibody to T. gondii was detected from day 7 (IgM) or 10 (IgG) and brain cysts were observed from day 14. Since detectable serum concentrations of NTPase appear to be associated with parasitaemia in both acute and chronic toxoplasmosis, the ABS-ELISA of the enzyme may make a useful diagnostic tool.
Collapse
Affiliation(s)
- T Kikuchi
- Department of Parasitology, The Institute of Medical Science, The University of Tokyo, Japan.
| | | | | |
Collapse
|
16
|
Motta CM, Beltrão EI, Amorim RV, Carvalho Júnior LB. Entamoeba histolytica and Entamoeba dispar in the northeast Brazil. Rev Inst Med Trop Sao Paulo 1997; 39:365-6. [PMID: 9674291 DOI: 10.1590/s0036-46651997000600012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
|
17
|
Lee M, Hong ST. Differentiation of Entamoeba histolytica and Entamoeba dispar in cyst-passers by immunoblot. THE KOREAN JOURNAL OF PARASITOLOGY 1996; 34:247-54. [PMID: 9017910 DOI: 10.3347/kjp.1996.34.4.247] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Differentiation of invasive strains of Entamoeba histolytica according to their pathogenicity has been a topic of long debate, but now the pathogenic species only is regarded as E. histolytica while the non pathogenic species is E. dispar. The present study applied immunoblot to differentiate infections of the two species among microscopically-detected cyst-passers in Korea. The crude extract of E. histolytica separated in 5.20% gradient gels, revealed many fractions of 94, 81, 71, 50, 44, 38.5, 37.5, 29, 19, and 18 kDa when the cysteine proteinase inhibitor, E64, was supplemented. The scrum IgG antibody of 3 proven E, histolytica cases reacted with the antigenic fractions of 117, 110, 99, 68, 66, 60, 54, 52, 46, and 45 kDa. Sera of PCR confirmed 3 cases of E. dispar reacted only to the 117 kDa fraction of the E. histolytica crude extract which was regarded as non-specific. To the antigen of monoxenic E. dispar, sera of E. dispar and E. histolytica cases showed the same immunoblot reactions. The serum IgA antibody reacted with several antigenic fractions of both E. histolytica and E. dispar, but IgM and IgE antibodies showed no reaction to either antigen. Sera of 24 symptomless amebic cyst passers were screened with the E. histolytica antigen; two were found to be infected by E. histolytica and 22 were by E. dispar. The present findings suggest that in Korea most of asymptomatic cyst passers of E. histolytica are carriers of E. dispar. Immunoblot using E. histolytica antigen is a good technique for the differentiation of E. histolytica and E. dispar infections.
Collapse
Affiliation(s)
- M Lee
- Department of Parasitology, Seoul National University College of Medicine, Korea
| | | |
Collapse
|