Trautner BW, Clarridge JE, Darouiche RO. Skin antisepsis kits containing alcohol and chlorhexidine gluconate or tincture of iodine are associated with low rates of blood culture contamination.
Infect Control Hosp Epidemiol 2002;
23:397-401. [PMID:
12138980 DOI:
10.1086/502073]
[Citation(s) in RCA: 36] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
OBJECTIVE
Skin preparation is an important factor in reducing the rate of blood culture contamination. We assessed blood culture contamination rates associated with the use of skin antisepsis kits containing either 2% alcoholic chlorhexidine gluconate or 2% alcoholic tincture of iodine.
DESIGN
Prospective, blinded clinical trial.
SETTING
Tertiary-care teaching hospital.
PATIENTS
Adult patients in medical wards, the medical intensive care unit, and the cardiac intensive care unit who needed paired, percutaneous blood cultures.
INTERVENTIONS
House officers, medical students, and healthcare technicians drew the blood for cultures. We prepared sacks containing all of the necessary supplies, including two different types of antiseptic kits. In each sack, one kit contained 2% chlorhexidine in 70% isopropyl alcohol and the other contained 2% tincture of iodine in ethyl alcohol and 70% isopropyl alcohol. Each patient received chlorhexidine at one site and tincture of iodine at the other.
RESULTS
Four (0.9%) of 430 blood culture sets from 215 patients were contaminated. The contamination rate when using alcohol and chlorhexidine (1 of 215, 0.5%) did not differ significantly from the contamination rate when using tincture of iodine (3 of 215, 1.4%; P = .62, McNemar test). There was an 87% probability that the two interventions differed by less than 2% in their rate of contamination.
CONCLUSIONS
Both of these antiseptic kits were highly effective for skin preparation prior to drawing blood for cultures. The use of these kits may have contributed to the low contamination rate observed in this study.