1
|
Abstract
Isotachophoresis (ITP) is a versatile electrophoretic technique that can be used for sample preconcentration, separation, purification, and mixing, and to control and accelerate chemical reactions. Although the basic technique is nearly a century old and widely used, there is a persistent need for an easily approachable, succinct, and rigorous review of ITP theory and analysis. This is important because the interest and adoption of the technique has grown over the last two decades, especially with its implementation in microfluidics and integration with on-chip chemical and biochemical assays. We here provide a review of ITP theory starting from physicochemical first-principles, including conservation of species, conservation of current, approximation of charge neutrality, pH equilibrium of weak electrolytes, and so-called regulating functions that govern transport dynamics, with a strong emphasis on steady and unsteady transport. We combine these generally applicable (to all types of ITP) theoretical discussions with applications of ITP in the field of microfluidic systems, particularly on-chip biochemical analyses. Our discussion includes principles that govern the ITP focusing of weak and strong electrolytes; ITP dynamics in peak and plateau modes; a review of simulation tools, experimental tools, and detection methods; applications of ITP for on-chip separations and trace analyte manipulation; and design considerations and challenges for microfluidic ITP systems. We conclude with remarks on possible future research directions. The intent of this review is to help make ITP analysis and design principles more accessible to the scientific and engineering communities and to provide a rigorous basis for the increased adoption of ITP in microfluidics.
Collapse
Affiliation(s)
- Ashwin Ramachandran
- Department
of Aeronautics and Astronautics, Stanford
University, Stanford, California 94305, United States
| | - Juan G. Santiago
- Department
of Mechanical Engineering, Stanford University, Stanford, California 94305, United States
| |
Collapse
|
2
|
Bender AT, Sullivan BP, Zhang JY, Juergens DC, Lillis L, Boyle DS, Posner JD. HIV detection from human serum with paper-based isotachophoretic RNA extraction and reverse transcription recombinase polymerase amplification. Analyst 2021; 146:2851-2861. [PMID: 33949378 PMCID: PMC9151496 DOI: 10.1039/d0an02483j] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
The number of people living with HIV continues to increase with the current total near 38 million, of which about 26 million are receiving antiretroviral therapy (ART). These treatment regimens are highly effective when properly managed, requiring routine viral load monitoring to assess successful viral suppression. Efforts to expand access by decentralizing HIV nucleic acid testing in low- and middle-income countries (LMICs) has been hampered by the cost and complexity of current tests. Sample preparation of blood samples has traditionally relied on cumbersome RNA extraction methods, and it continues to be a key bottleneck for developing low-cost POC nucleic acid tests. We present a microfluidic paper-based analytical device (μPAD) for extracting RNA and detecting HIV in serum, leveraging low-cost materials, simple buffers, and an electric field. We detect HIV virions and MS2 bacteriophage internal control in human serum using a novel lysis and RNase inactivation method, paper-based isotachophoresis (ITP) for RNA extraction, and duplexed reverse transcription recombinase polymerase amplification (RT-RPA) for nucleic acid amplification. We design a specialized ITP system to extract and concentrate RNA, while excluding harsh reagents used for lysis and RNase inactivation. We found the ITP μPAD can extract and purify 5000 HIV RNA copies per mL of serum. We then demonstrate detection of HIV virions and MS2 bacteriophage in human serum within 45-minutes.
Collapse
Affiliation(s)
- Andrew T Bender
- Department of Mechanical Engineering, University of Washington, Seattle, USA.
| | - Benjamin P Sullivan
- Department of Mechanical Engineering, University of Washington, Seattle, USA.
| | - Jane Y Zhang
- Department of Mechanical Engineering, University of Washington, Seattle, USA.
| | - David C Juergens
- Department of Chemical Engineering, University of Washington, Seattle, USA
| | | | | | - Jonathan D Posner
- Department of Mechanical Engineering, University of Washington, Seattle, USA. and Department of Chemical Engineering, University of Washington, Seattle, USA and Family Medicine, School of Medicine, University of Washington, Seattle, USA
| |
Collapse
|
3
|
Sullivan BP, Bender AT, Ngyuen DN, Zhang JY, Posner JD. Nucleic acid sample preparation from whole blood in a paper microfluidic device using isotachophoresis. J Chromatogr B Analyt Technol Biomed Life Sci 2020; 1163:122494. [PMID: 33401049 DOI: 10.1016/j.jchromb.2020.122494] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2020] [Revised: 12/03/2020] [Accepted: 12/05/2020] [Indexed: 02/08/2023]
Abstract
Nucleic acid amplification tests (NAATs) are a crucial diagnostic and monitoring tool for infectious diseases. A key procedural step for NAATs is sample preparation: separating and purifying target nucleic acids from crude biological samples prior to nucleic acid amplification and detection. Traditionally, sample preparation has been performed with liquid- or solid-phase extraction, both of which require multiple trained user steps and significant laboratory equipment. The challenges associated with sample preparation have limited the dissemination of NAAT point-of-care diagnostics in low resource environments, including low- and middle-income countries. We report on a paper-based device for purification of nucleic acids from whole blood using isotachophoresis (ITP) for point-of-care NAATs. We show successful extraction and purification of target nucleic acids from large volumes (33 µL) of whole human blood samples with no moving parts and few user steps. Our device utilizes paper-based buffer reservoirs to fully contain the liquid ITP buffers and does not require complex filling procedures, instead relying on the natural wicking of integrated paper membranes. We perform on-device blood fractionation via filtration to remove leukocytes and erythrocytes from our sample, followed by integrated on-paper proteolytic digestion of endogenous plasma proteins to allow for successful isotachophoretic extraction. Paper-based isotachophoresis purifies and concentrates target nucleic acids that are added directly to recombinase polymerase amplification (RPA) reactions. We show consistent amplification of input copy concentrations of as low as 3 × 103 copies nucleic acid per mL input blood with extraction and purification taking only 30 min. By employing a paper architecture, we are able to incorporate these processes in a single, robust, low-cost design, enabling the direct processing of large volumes of blood, with the only intermediate user steps being the removal and addition of tape. Our device represents a step towards a simple, fully integrated sample preparation system for nucleic acid amplification tests at the point-of-care.
Collapse
Affiliation(s)
- Benjamin P Sullivan
- Department of Mechanical Engineering, University of Washington, Seattle, WA, USA
| | - Andrew T Bender
- Department of Mechanical Engineering, University of Washington, Seattle, WA, USA
| | - Duy N Ngyuen
- Department of Chemical Engineering, University of Washington, Seattle, WA, USA
| | - Jane Yuqian Zhang
- Department of Mechanical Engineering, University of Washington, Seattle, WA, USA
| | - Jonathan D Posner
- Department of Mechanical Engineering, University of Washington, Seattle, WA, USA; Department of Chemical Engineering, University of Washington, Seattle, WA, USA; Department of Family Medicine, University of Washington, Seattle, WA, USA.
| |
Collapse
|
4
|
Burel C, Direur G, Rivas C, Purevdorj-Gage L. Colorimetric detection of residual quaternary ammonium compounds on dry surfaces and prediction of antimicrobial activity using bromophenol blue. Lett Appl Microbiol 2020; 72:358-365. [PMID: 33191523 DOI: 10.1111/lam.13429] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2020] [Revised: 11/09/2020] [Accepted: 11/10/2020] [Indexed: 01/22/2023]
Abstract
Controlling and monitoring the residual activity of quaternary ammonium compounds (QACs) are critical for maintaining safe yet effective levels of these agents in the environment. This study investigates the utility of bromophenol blue (BPB) as a safe, rapid and user-friendly indicator to detect in situ residual QACs dried on hard, non-porous surfaces, as well a means to assess their antimicrobial efficacy. At pH 7, BPB has a purple colour which turns blue upon its complexation with QACs such as didecyldimethylammonium chloride (DDAC). BPB itself has no antimicrobial properties up to 400 ppm. Within the range of 0-400 ppm, BPB colour change was tied to specific DDAC antimicrobial performances with a detection threshold of 100 ppm. BPB concentration and application volume could be adjusted such that a colour shift from purple to blue correlated with a set percent reduction (>99·9%) in test bacteria (Staphylococcus aureus and Klebsiella aerogenes). The BPB solutions developed in this study yielded similar colour shifts on polycarbonate and stainless steel surfaces and did not cross-react with chemical ingredients commonly found in sanitizers and disinfectant products. Overall, this study suggests that BPB provides a simple solution to safely monitor the post-application level and biocidal activity of residual dried QACs on surfaces.
Collapse
Affiliation(s)
- C Burel
- Complex Assemblies of Soft Matter Laboratory (COMPASS), UMI 3254, CNRS-Solvay-University of Pennsylvania, CRTB, Bristol, PA, USA
| | - G Direur
- Complex Assemblies of Soft Matter Laboratory (COMPASS), UMI 3254, CNRS-Solvay-University of Pennsylvania, CRTB, Bristol, PA, USA
| | - C Rivas
- Solvay, CRTB, Bristol, PA, USA
| | | |
Collapse
|
5
|
Kondratova VN, Botezatu IV, Shelepov VP, Lichtenstein AV. Satellite DNA transcripts in blood plasma as potential markers of tumor growth. Mol Biol 2014. [DOI: 10.1134/s0026893314060089] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
|
6
|
Qu Y, Marshall LA, Santiago JG. Simultaneous Purification and Fractionation of Nucleic Acids and Proteins from Complex Samples Using Bidirectional Isotachophoresis. Anal Chem 2014; 86:7264-8. [DOI: 10.1021/ac501299a] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Yatian Qu
- Department
of Mechanical Engineering, Stanford University, Stanford, California 94305, United States
| | - Lewis A. Marshall
- Department
of Chemical Engineering, Stanford University, Stanford, California 94305, United States
| | - Juan G. Santiago
- Department
of Mechanical Engineering, Stanford University, Stanford, California 94305, United States
| |
Collapse
|
7
|
Purification of nucleic acids using isotachophoresis. J Chromatogr A 2014; 1335:105-20. [DOI: 10.1016/j.chroma.2013.12.027] [Citation(s) in RCA: 70] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2013] [Revised: 12/04/2013] [Accepted: 12/07/2013] [Indexed: 12/30/2022]
|
8
|
Marshall LA, Rogacs A, Meinhart CD, Santiago JG. An injection molded microchip for nucleic acid purification from 25 microliter samples using isotachophoresis. J Chromatogr A 2014; 1331:139-42. [PMID: 24485540 DOI: 10.1016/j.chroma.2014.01.036] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2013] [Revised: 01/07/2014] [Accepted: 01/10/2014] [Indexed: 11/24/2022]
Abstract
We present a novel microchip device for purification of nucleic acids from 25μL biological samples using isotachophoresis (ITP). The device design incorporates a custom capillary barrier structure to facilitate robust sample loading. The chip uses a 2mm channel width and 0.15mm depth to reduce processing time, mitigate Joule heating, and achieve high extraction efficiency. To reduce pH changes in the device due to electrolysis, we incorporated a buffering reservoir physically separated from the sample output reservoir. To reduce dispersion of the ITP-focused zone, we used optimized turn geometries. The chip was fabricated by injection molding PMMA and COC plastics through a commercial microfluidic foundry. The extraction efficiency of nucleic acids from the device was measured using fluorescent quantification, and an average recovery efficiency of 81% was achieved for nucleic acid masses between 250pg and 250ng. The devices were also used to purify DNA from whole blood, and the extracted DNA was amplified using qPCR to show the PCR compatibility of the purified sample.
Collapse
Affiliation(s)
- L A Marshall
- Department of Chemical Engineering, Stanford University, USA
| | - A Rogacs
- Department of Mechanical Engineering, Stanford University, USA
| | - C D Meinhart
- Department of Mechanical Engineering, UC Santa Barbara, USA
| | - J G Santiago
- Department of Mechanical Engineering, Stanford University, USA.
| |
Collapse
|
9
|
Kondratova VN, Botezatu IV, Shelepov VP, Lichtenstein AV. Tube gel isotachophoresis: A method for quantitative isolation of nucleic acids from diluted solutions. Anal Biochem 2011; 408:304-8. [DOI: 10.1016/j.ab.2010.09.004] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2010] [Revised: 08/31/2010] [Accepted: 09/01/2010] [Indexed: 11/28/2022]
|