1
|
Biocompatibility and Mechanical Stability of Nanopatterned Titanium Films on Stainless Steel Vascular Stents. Int J Mol Sci 2022; 23:ijms23094595. [PMID: 35562988 PMCID: PMC9099593 DOI: 10.3390/ijms23094595] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2022] [Revised: 04/16/2022] [Accepted: 04/18/2022] [Indexed: 01/27/2023] Open
Abstract
Nanoporous ceramic coatings such as titania are promoted to produce drug-free cardiovascular stents with a low risk of in-stent restenosis (ISR) because of their selectivity towards vascular cell proliferation. The brittle coatings applied on stents are prone to cracking because they are subjected to plastic deformation during implantation. This study aims to overcome this problem by using a unique process without refraining from biocompatibility. Accordingly, a titanium film with 1 µm thickness was deposited on 316 LVM stainless-steel sheets using magnetron sputtering. Then, the samples were anodized to produce nanoporous oxide. The nanoporous oxide was removed by ultrasonication, leaving an approximately 500 nm metallic titanium layer with a nanopatterned surface. XPS studies revealed the presence of a 5 nm-thick TiO2 surface layer with a trace amount of fluorinated titanium on nanopatterned surfaces. Oxygen plasma treatment of the nanopatterned surface produced an additional 5 nm-thick fluoride-free oxide layer. The samples did not exhibit any cracking or spallation during plastic deformation. Cell viability studies showed that nanopatterned surfaces stimulate endothelial cell proliferation while reducing the proliferation of smooth muscle cells. Plasma treatment further accelerated the proliferation of endothelial cells. Activation of blood platelets did not occur on oxygen plasma-treated, fluoride-free nanopatterned surfaces. The presented surface treatment method can also be applied to other stent materials such as CoCr, nitinol, and orthopedic implants.
Collapse
|
2
|
Addressing the Needs of the Rapidly Aging Society through the Development of Multifunctional Bioactive Coatings for Orthopedic Applications. Int J Mol Sci 2022; 23:ijms23052786. [PMID: 35269928 PMCID: PMC8911303 DOI: 10.3390/ijms23052786] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Revised: 02/27/2022] [Accepted: 02/28/2022] [Indexed: 12/15/2022] Open
Abstract
The unprecedented aging of the world's population will boost the need for orthopedic implants and expose their current limitations to a greater extent due to the medical complexity of elderly patients and longer indwelling times of the implanted materials. Biocompatible metals with multifunctional bioactive coatings promise to provide the means for the controlled and tailorable release of different medications for patient-specific treatment while prolonging the material's lifespan and thus improving the surgical outcome. The objective of this work is to provide a review of several groups of biocompatible materials that might be utilized as constituents for the development of multifunctional bioactive coatings on metal materials with a focus on antimicrobial, pain-relieving, and anticoagulant properties. Moreover, the review presents a summary of medications used in clinical settings, the disadvantages of the commercially available products, and insight into the latest development strategies. For a more successful translation of such research into clinical practice, extensive knowledge of the chemical interactions between the components and a detailed understanding of the properties and mechanisms of biological matter are required. Moreover, the cost-efficiency of the surface treatment should be considered in the development process.
Collapse
|
3
|
Nasakina EO, Konushkin SV, Sudarchikova MA, Sergienko KV, Baikin AS, Tsareva AM, Kaplan MA, Kolmakov AG, Sevost’yanov MA. Obtaining a Wire of Biocompatible Superelastic Alloy Ti-28Nb-5Zr. MATERIALS (BASEL, SWITZERLAND) 2020; 13:E2187. [PMID: 32397478 PMCID: PMC7254264 DOI: 10.3390/ma13092187] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/16/2020] [Revised: 05/01/2020] [Accepted: 05/07/2020] [Indexed: 06/11/2023]
Abstract
Using the methods of electric arc melting, intermediate heat treatments, and consecutive intensive plastic deformation, a Ti-Nb-Zr alloy wire with a diameter of 1200 μm was obtained with a homogeneous chemical and phase (β-Ti body-centered crystal lattice) composition corresponding to the presence of superelasticity and shape memory effect, corrosion resistance and biocompatibility. Perhaps the wire structure is represented by grains with a nanoscale diameter. For the wire obtained after stabilizing annealing, the proof strength Rp0.2 is 635 MPa, tensile strength is 840 MPa and Young's modulus is 22 GPa, relative elongation is 6.76%. No toxicity was detected. The resulting wire is considered to be promising for medical use.
Collapse
Affiliation(s)
- Elena O. Nasakina
- A.A. Baikov Institute of Metallurgy and Material Science RAS (IMET RAS), Institution of Russian Academy of Sciences, Leninsky Prospect, 49, 119991 Moscow, Russia; (S.V.K.); (M.A.S.); (K.V.S.); (A.S.B.); (A.M.T.); (M.A.K.); (A.G.K.); (M.A.S.)
| | | | | | | | | | | | | | | | | |
Collapse
|
4
|
Baikin AS, Kaplan MA, Nasakina EO, Shatova LA, Tsareva AM, Kolmakova AA, Danilova EA, Tishurova YA, Bunkin NF, Gudkov SV, Belosludtsev KN, Glinushkin AP, Kolmakov AG, Sevostyanov MA. Development of a Biocompatible and Biodegradable Polymer Capable of Long-Term Release of Biologically Active Substances for Medicine and Agriculture. DOKLADY CHEMISTRY 2019. [DOI: 10.1134/s0012500819110041] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
5
|
Nasakina EO, Sudarchikova MA, Sergienko KV, Konushkin SV, Sevost’yanov MA. Ion Release and Surface Characterization of Nanostructured Nitinol during Long-Term Testing. NANOMATERIALS (BASEL, SWITZERLAND) 2019; 9:E1569. [PMID: 31694335 PMCID: PMC6915401 DOI: 10.3390/nano9111569] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/14/2019] [Revised: 10/17/2019] [Accepted: 10/28/2019] [Indexed: 11/27/2022]
Abstract
The corrosion resistance of nanostructured nitinol (NiTi) was investigated using long-term tests in solutions simulating physiological fluids at static conditions, reflecting the material structure and metal concentration in the solutions. Mechanical polishing reduced the ion release by a factor of two to three, whereas annealing deteriorated the corrosion resistance. The depassivation and repassivation of nitinol surfaces were considered. We found that nanostructured nitinol might increase the corrosion leaching of titanium into solutions, although the nickel release decreased. Metal dissolution did not occur in the alkaline environment or artificial plasma. A Ni-free surface with a protective 25 nm-thick titanium oxide film resulted from soaking mechanically treated samples of the NiTi wire in a saline solution for two years under static conditions. Hence, the medical application of nanostructured NiTi, such as for the production of medical devices and implants such as stents, shows potential compared with microstructured NiTi.
Collapse
Affiliation(s)
- Elena O. Nasakina
- Laboratory of Durability and Plasticity of Metal and Composite Materials and Nanomaterials, Institution of Russian Academy of Sciences, A.A. Baikov Institute of Metallurgy and Material Science RAS (IMET RAS), Leninsky Prospect 49, 119991 Moscow, Russia; (M.A.S.); (K.V.S.); (S.V.K.); (M.A.S.)
| | | | | | | | | |
Collapse
|
6
|
Sevostyanov MA, Baikin AS, Shatova LA, Nasakina EO, Berezhnov AV, Gudkov SV, Sergienko KV, Konushkin SV, Baskakova MI, Kolmakov AG. Biocompatibility of the Ti81Nb13Ta3Zr3 Alloy. DOKLADY CHEMISTRY 2018. [DOI: 10.1134/s0012500818090045] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
7
|
Sevost'yanov MA, Nasakina EO, Baikin AS, Sergienko KV, Konushkin SV, Kaplan MA, Seregin AV, Leonov AV, Kozlov VA, Shkirin AV, Bunkin NF, Kolmakov AG, Simakov SV, Gudkov SV. Biocompatibility of new materials based on nano-structured nitinol with titanium and tantalum composite surface layers: experimental analysis in vitro and in vivo. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2018; 29:33. [PMID: 29546502 DOI: 10.1007/s10856-018-6039-3] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/07/2017] [Accepted: 03/05/2018] [Indexed: 06/08/2023]
Abstract
A technology for obtaining materials from nanostructured nitinol with titanium- or tantalum-enriched surface layers was developed. Surface layers enriched with titanium or tantalum were shown to provide a decrease in the formation of reactive oxygen species and long-lived protein radicals in comparison to untreated nitinol. It was determined that human peripheral vessel myofibroblasts and human bone marrow mesenchymal stromal cells grown on nitinol bases coated with titanium or tantalum-enriched surface layers exhibit a nearly two times higher mitotic index. Response to implantation of pure nitinol, as well as nano-structure nitinol with titanium or tantalum-enriched surface layers, was expressed though formation of a mature uniform fibrous capsule peripherally to the fragment. The thickness of this capsule in the group of animals subjected to implantation of pure nitinol was 1.5 and 3.0-fold greater than that of the capsule in the groups implanted with nitinol fragments with titanium- or tantalum-enriched layers. No signs of calcinosis in the tissues surrounding implants with coatings were observed. The nature and structure of the formed capsules testify bioinertia of the implanted samples. It was shown that the morphology and composition of the surface of metal samples does not alter following biological tests. The obtained results indicate that nano-structure nitinol with titanium or tantalum enriched surface layers is a biocompatible material potentially suitable for medical applications.
Collapse
Affiliation(s)
- Mikhail A Sevost'yanov
- Baikov Institute of Metallurgy and Materials Science, Russian Academy of Sciences, Moscow, Russia
| | - Elena O Nasakina
- Baikov Institute of Metallurgy and Materials Science, Russian Academy of Sciences, Moscow, Russia
| | - Alexander S Baikin
- Baikov Institute of Metallurgy and Materials Science, Russian Academy of Sciences, Moscow, Russia
| | - Konstantin V Sergienko
- Baikov Institute of Metallurgy and Materials Science, Russian Academy of Sciences, Moscow, Russia
| | - Sergey V Konushkin
- Baikov Institute of Metallurgy and Materials Science, Russian Academy of Sciences, Moscow, Russia
| | - Mikhail A Kaplan
- Baikov Institute of Metallurgy and Materials Science, Russian Academy of Sciences, Moscow, Russia
| | - Alexey V Seregin
- Baikov Institute of Metallurgy and Materials Science, Russian Academy of Sciences, Moscow, Russia
- Bauman Moscow State Technical University, Moscow, Russia
| | - Alexander V Leonov
- Baikov Institute of Metallurgy and Materials Science, Russian Academy of Sciences, Moscow, Russia
- Bauman Moscow State Technical University, Moscow, Russia
| | - Valery A Kozlov
- Bauman Moscow State Technical University, Moscow, Russia
- A.M. Prokhorov General Physics Institute, Russian Academy of Sciences, Moscow, Russia
| | - Alexey V Shkirin
- A.M. Prokhorov General Physics Institute, Russian Academy of Sciences, Moscow, Russia
- National Research Nuclear University MEPhI, Moscow, Russia
| | - Nikolai F Bunkin
- Bauman Moscow State Technical University, Moscow, Russia
- A.M. Prokhorov General Physics Institute, Russian Academy of Sciences, Moscow, Russia
| | - Alexey G Kolmakov
- Baikov Institute of Metallurgy and Materials Science, Russian Academy of Sciences, Moscow, Russia
| | - Sergey V Simakov
- Baikov Institute of Metallurgy and Materials Science, Russian Academy of Sciences, Moscow, Russia
| | - Sergey V Gudkov
- A.M. Prokhorov General Physics Institute, Russian Academy of Sciences, Moscow, Russia.
- Depatment of Biophysics, Lobachevsky State University of Nizhni Novgorod, Nizhni Novgorod, Russia.
- Moscow Regional Research and Clinical Institute (MONIKI), Moscow, Russia.
| |
Collapse
|