1
|
Salih FA, Novakovskii AD, Egorov VV. Insight into response of ion-exchanger-based electrodes sensitive to highly lipophilic physiologically active amines. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2022.116561] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
2
|
Dynamic Potentiometry with an Ion-Selective Electrode: A Tool for Qualitative and Quantitative Analysis of Inorganic and Organic Cations. CHEMOSENSORS 2022. [DOI: 10.3390/chemosensors10030116] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
A study of the transient potential signals obtained with a cation-selective electrode based on an ion-exchanger was carried out for solutions of the following individual cations at different concentrations: H+, Li+, Na+, K+, Rb+, Mg2+, Ca2+, choline (Ch+), acetylcholine (AcCh+), and procaine (Pr+). Three different general types of transient signals were distinguished depending on the value of the selectivity coefficient of the corresponding ion. A principal component analysis (PCA) was performed on the signals, finding that the qualitative identification of the corresponding ion from the scores of two principal components is possible. The study was extended to the transient signals of solutions containing an analyte in the presence of an interfering ion. The PCA of the corresponding signal allows for the detection of the presence of interfering ions, thus avoiding biased results in the determination of the analyte. Moreover, the two principal components of the transient signals obtained for each of the ions at different concentrations allow for the construction of calibration graphs for the quantitative determination of the corresponding ion. All the transient signals obtained experimentally in this work can be reconstructed accurately from principal components and their corresponding scores.
Collapse
|
3
|
Fan Y, Qian X, Wang X, Funk T, Herman B, McCutcheon JR, Li B. Enhancing long-term accuracy and durability of wastewater monitoring using electrosprayed ultra-thin solid-state ion selective membrane sensors. J Memb Sci 2022. [DOI: 10.1016/j.memsci.2021.119997] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
4
|
Abstract
The application of white box models in digital twins is often hindered by missing knowledge, uncertain information and computational difficulties. Our aim was to overview the difficulties and challenges regarding the modelling aspects of digital twin applications and to explore the fields where surrogate models can be utilised advantageously. In this sense, the paper discusses what types of surrogate models are suitable for different practical problems as well as introduces the appropriate techniques for building and using these models. A number of examples of digital twin applications from both continuous processes and discrete manufacturing are presented to underline the potentials of utilising surrogate models. The surrogate models and model-building methods are categorised according to the area of applications. The importance of keeping these models up to date through their whole model life cycle is also highlighted. An industrial case study is also presented to demonstrate the applicability of the concept.
Collapse
|
5
|
Hambly B, Guzinski M, Pendley B, Lindner E. Kinetic Description of the Membrane-Solution Interface for Ion-Selective Electrodes. ACS Sens 2020; 5:2146-2154. [PMID: 32560587 DOI: 10.1021/acssensors.0c00774] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
The theoretical models for ISEs almost exclusively assume thermodynamic equilibrium at the membrane/solution-phase boundary. In this report, we present a new, congruent model which combines first-order reaction kinetics of ion-exchange at the phase boundary and diffusional mass transport in the adjoining phases in the continuity equation. The influence of the rate constant in the new kinetic model has significant impact on the predicted transients corresponding to instantaneous change in the sample solution composition. The simulated transients generated with the new model coincide with the transients recorded in common potentiometric experiments, e.g., with transients recorded upon step change in the primary or interfering ion concentrations. The simulated transients also align well with previously published transients representing special cases of potentiometry (e.g., super-Nernstian response, non-Nernstian responses in the presence of highly interfering ions). The implementation of the kinetic model for simulating the transients in the water layer test also resulted in a better agreement with the experiments compared to the previous models.
Collapse
Affiliation(s)
- Bradley Hambly
- Department of Biomedical Engineering, University of Memphis, Memphis, Tennessee 38152, United States
| | - Marcin Guzinski
- Vanderbilt Eye Institute, Vanderbilt University Medical Center, Nashville, Tennessee 37232, United States
| | - Bradford Pendley
- Department of Biomedical Engineering, University of Memphis, Memphis, Tennessee 38152, United States
| | - Ernő Lindner
- Department of Biomedical Engineering, University of Memphis, Memphis, Tennessee 38152, United States
| |
Collapse
|
6
|
Egorov VV, Novakovskii AD, Salih FA, Semenov AV, Akayeu YB. Description of the Effects of Non‐ion‐exchange Extraction and Intra‐membrane Interactions on the Ion‐selective Electrodes Response within the Interface Equilibria‐triggered Model. ELECTROANAL 2020. [DOI: 10.1002/elan.201900647] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Vladimir V. Egorov
- Belarusian State UniversityChemistry Department Minsk Belarus
- Research Institute for Physical Chemical Problems of theBelarusian State University Minsk Belarus
| | - Andrei D. Novakovskii
- Belarusian State UniversityChemistry Department Minsk Belarus
- Research Institute for Physical Chemical Problems of theBelarusian State University Minsk Belarus
| | - Faisal A. Salih
- Belarusian State UniversityChemistry Department Minsk Belarus
- Technical College of HealthSulaimani Polytechnic University Sulamani, Kurdistan Iraq
| | | | | |
Collapse
|
7
|
Egorov VV, Novakovskii AD. On the possibilities of potentiometric analysis in presence of small concentrations of highly interfering foreign ions: Ways for reducing the interference. J Electroanal Chem (Lausanne) 2019. [DOI: 10.1016/j.jelechem.2019.113234] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
8
|
Egorov VV, Novakovskii AD. Overcoming of One More Pitfall in Boundary Element Calculations with Computer Simulations of Ion-Selective Electrode Response. ACS OMEGA 2019; 4:1617-1622. [PMID: 31459419 PMCID: PMC6649265 DOI: 10.1021/acsomega.8b02926] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/24/2018] [Accepted: 01/08/2019] [Indexed: 06/10/2023]
Abstract
Computer simulations of ion-selective membrane electrodes using diffusion layer models based on finite-differences principle for calculating diffusion processes in both phases and taking into account the local ion exchange equilibrium at the interface are successfully used for clarifying and even predicting the influence of different diffusion factors on several time-dependent characteristics of electrodes. It is shown here that a well-established approach based on the assumption of the constant concentration of the interfering ion in the sample solution fails for solutions containing strongly interfering ions where the concentration of the interfering ion in the boundary layer of the solution can be far lower in comparison with its concentration in the bulk. The limitation is demonstrated by a drastic discrepancy between experimental and calculated curves for the dependence of potential on time. This limitation can be overcome by taking into account the change of the interfering ion concentration in the boundary layer in accordance with the electroneutrality condition. A good agreement between simulation results and experimental data is demonstrated.
Collapse
Affiliation(s)
- Vladimir V. Egorov
- Department
of Analytical Chemistry, Belarusian State
University, Leningradskaya Str., 14, 220030 Minsk, Belarus
| | - Andrei D. Novakovskii
- Research
Institute for Physical Chemical Problems of the Belarusian State University, Leningradskaya Str., 14, 220030 Minsk, Belarus
| |
Collapse
|
9
|
Affiliation(s)
- Elena Zdrachek
- Department of Inorganic and Analytical Chemistry, University of Geneva, Quai Ernest-Ansermet 30, CH-1211 Geneva, Switzerland
| | - Eric Bakker
- Department of Inorganic and Analytical Chemistry, University of Geneva, Quai Ernest-Ansermet 30, CH-1211 Geneva, Switzerland
| |
Collapse
|
10
|
Egorov VV, Novakovskii AD. Application of the interface equilibria-triggered dynamic diffusion model of the boundary potential for the numerical simulation of neutral carrier-based ion-selective electrodes response. Anal Chim Acta 2018; 1043:20-27. [PMID: 30392665 DOI: 10.1016/j.aca.2018.08.043] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2018] [Revised: 07/04/2018] [Accepted: 08/23/2018] [Indexed: 11/29/2022]
Abstract
It is shown that a simple dynamic diffusion model of the boundary potential based on a separate, step-by-step, account of ion transfer across the membrane/aqueous solution interface and the diffusion processes within both phases which was proposed earlier for describing the response of ionophore-free membranes, can be successfully used for ionophore-based membranes as well. The model makes it possible to carry out both separate and joint account of the effects of co-extraction, transmembrane transport and ion exchange on the boundary potential and retains robustness in all the variants studied. The model adequately describes the ionophore-based electrode response over the entire range of concentrations and allows one to clearly demonstrate the dependence of lower detection limit on such parameters as the diffusion coefficients and the concentration of electroactive substances in the membrane phase, the thickness of the diffusion layer in the sample solution, the duration of the measurement, and the composition of the internal reference solution. The results of numerical simulation are in good agreement with the experimental data presented in the literature. As all the factors of influence considered above can easily be regulated in more or less wide limits, but at the same time, an estimation of their cumulative effect is not always possible on an intuitive level, the present model can be of practical interest for justifying the ways of optimizing the design of the ISE and the algorithm for performing measurements in solving specific analytical problems.
Collapse
Affiliation(s)
- Vladimir V Egorov
- Department of Analytical Chemistry, Belarusian State University, Leningradskaya Str., 14, 220030, Minsk, Belarus.
| | - Andrei D Novakovskii
- Research Institute for Physical Chemical Problems of the Belarusian State University, Leningradskaya Str., 14, 220030, Minsk, Belarus
| |
Collapse
|
11
|
Jasielec JJ, Mousavi Z, Granholm K, Sokalski T, Lewenstam A. Sensitivity and Selectivity of Ion-Selective Electrodes Interpreted Using the Nernst-Planck-Poisson Model. Anal Chem 2018; 90:9644-9649. [DOI: 10.1021/acs.analchem.8b02659] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Jerzy J. Jasielec
- AGH University of Science and Technology, Faculty of Materials Science and Ceramics, Physical Chemistry and Modeling Department, Al. Mickiewicza 30, 30-059 Kraków, Poland
| | - Zekra Mousavi
- Johan Gadolin Process Chemistry Centre, c/o Centre for Process Analytical Chemistry and Sensor Technology (ProSens), Åbo Akademi University, Biskopsgatan 8, 20500 Åbo-Turku, Finland
| | - Kim Granholm
- Johan Gadolin Process Chemistry Centre, c/o Centre for Process Analytical Chemistry and Sensor Technology (ProSens), Åbo Akademi University, Biskopsgatan 8, 20500 Åbo-Turku, Finland
| | - Tomasz Sokalski
- Johan Gadolin Process Chemistry Centre, c/o Centre for Process Analytical Chemistry and Sensor Technology (ProSens), Åbo Akademi University, Biskopsgatan 8, 20500 Åbo-Turku, Finland
| | - Andrzej Lewenstam
- AGH University of Science and Technology, Faculty of Materials Science and Ceramics, Physical Chemistry and Modeling Department, Al. Mickiewicza 30, 30-059 Kraków, Poland
- Johan Gadolin Process Chemistry Centre, c/o Centre for Process Analytical Chemistry and Sensor Technology (ProSens), Åbo Akademi University, Biskopsgatan 8, 20500 Åbo-Turku, Finland
| |
Collapse
|
12
|
Egorov VV, Novakovskii AD, Zdrachek EA. An Interface Equilibria-Triggered Time-Dependent Diffusion Model of the Boundary Potential and Its Application for the Numerical Simulation of the Ion-Selective Electrode Response in Real Systems. Anal Chem 2017; 90:1309-1316. [DOI: 10.1021/acs.analchem.7b04134] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Affiliation(s)
- Vladimir V. Egorov
- Department
of Analytical Chemistry, Belarusian State University, Leningradskaya
Str., 14, 220030 Minsk, Belarus
| | - Andrei D. Novakovskii
- Department
of Analytical Chemistry, Belarusian State University, Leningradskaya
Str., 14, 220030 Minsk, Belarus
- Research Institute for Physical Chemical Problems of the Belarusian State University, Leningradskaya Str., 14, 220030 Minsk, Belarus
| | - Elena A. Zdrachek
- Research Institute for Physical Chemical Problems of the Belarusian State University, Leningradskaya Str., 14, 220030 Minsk, Belarus
- Department
of Inorganic and Analytical Chemistry, University of Geneva, Quai Ernest-Ansermet
30, CH-1211 Geneva, Switzerland
| |
Collapse
|
13
|
Zdrachek E, Bakker E. Describing Ion Exchange at Membrane Electrodes for Ions of Different Charge. ELECTROANAL 2017. [DOI: 10.1002/elan.201700700] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Affiliation(s)
- Elena Zdrachek
- Department of Inorganic and Analytical Chemistry; University of Geneva; Quai Ernest-Ansermet 30 CH-1211 Geneva Switzerland
| | - Eric Bakker
- Department of Inorganic and Analytical Chemistry; University of Geneva; Quai Ernest-Ansermet 30 CH-1211 Geneva Switzerland
| |
Collapse
|