1
|
Farag AS, Rizk M, Mohamed OM, Azab MM. A novel turn-off green carbon dot-based fluorescent probe for selective determination of nitrazepam in its pharmaceutical dosage form and milk samples. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2024; 16:6373-6382. [PMID: 39221649 DOI: 10.1039/d4ay01216j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/04/2024]
Abstract
In this study, a new, rapid, simple, and cost-effective fluorescent probe based on carbon dots (CDs) has been developed for the selective determination of nitrazepam (NZP). The CDs were synthesized with high production yield (71.43%) through one step carbonization of dried banana peels. The fluorescence intensity of the CDs is quenched by increasing the NZP concentration as a result of the inner-filter effect and dynamic quenching mechanism. This fluorescent sensor effectively quantified NZP in the linear range of 0.30-26 μg mL-1, with a limit of detection of 0.10 μg mL-1. The performance of the sensor was validated according to ICH guidelines and exhibited high precision and accuracy. The proposed method was also successfully extended for determining NZP in tablet dosage form and milk samples.
Collapse
Affiliation(s)
- Amir Shaaban Farag
- Department of Analytical Chemistry, Faculty of Pharmacy, Helwan University, Helwan, 11795 Cairo, Egypt.
| | - Mohamed Rizk
- Department of Analytical Chemistry, Faculty of Pharmacy, Helwan University, Helwan, 11795 Cairo, Egypt.
| | - Omaima Mahmoud Mohamed
- Department of Analytical Chemistry, Faculty of Pharmacy, Helwan University, Helwan, 11795 Cairo, Egypt.
| | - Marwa Mohamed Azab
- Department of Analytical Chemistry, Faculty of Pharmacy, Helwan University, Helwan, 11795 Cairo, Egypt.
| |
Collapse
|
2
|
Stelmaszczyk P, Kwaczyński K, Rudnicki K, Skrzypek S, Wietecha-Posłuszny R, Poltorak L. Nitrazepam and 7-aminonitrazepam studied at the macroscopic and microscopic electrified liquid-liquid interface. Mikrochim Acta 2023; 190:182. [PMID: 37052720 PMCID: PMC10101902 DOI: 10.1007/s00604-023-05739-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2022] [Accepted: 03/09/2023] [Indexed: 04/14/2023]
Abstract
Two benzodiazepine type drugs, that is, nitrazepam and 7-aminonitrazepam, were studied at the electrified liquid-liquid interface (eLLI). Both drugs are illicit and act sedative in the human body and moreover are used as date rape drugs. Existence of the diazepine ring in the concerned chemicals structure and one additional amine group (for 7-aminonitrazepam) allows for the molecular charging below their pKa values, and hence, both drugs can cross the eLLI interface upon application of the appropriate value of the Galvani potential difference. Chosen molecules were studied at the macroscopic eLLI formed in the four electrode cell and microscopic eLLI formed within a microtip defined as the single pore having 25 μm in diameter. Microscopic eLLI was formed using only a few μL of the organic and the aqueous phase with the help of a 3D printed cell. Parameters such as limit of detection and voltammetric detection sensitivity are derived from the experimental data. Developed methodology was used to detect nitrazepam in pharmaceutical formulation and both drugs (nitrazepam and 7-aminonitrazepam) in spiked biological fluids (urine and blood).
Collapse
Affiliation(s)
- Paweł Stelmaszczyk
- Laboratory for Forensic Chemistry, Department of Analytical Chemistry, Faculty of Chemistry, Jagiellonian University, Gronostajowa 2, 30-387, Krakow, Poland
| | - Karolina Kwaczyński
- Electrochemistry@Soft Interfaces Team, Department of Inorganic and Analytical Chemistry, Faculty of Chemistry, University of Lodz, Tamka 12, 91-403, Lodz, Poland
| | - Konrad Rudnicki
- Electrochemistry@Soft Interfaces Team, Department of Inorganic and Analytical Chemistry, Faculty of Chemistry, University of Lodz, Tamka 12, 91-403, Lodz, Poland
| | - Sławomira Skrzypek
- Electrochemistry@Soft Interfaces Team, Department of Inorganic and Analytical Chemistry, Faculty of Chemistry, University of Lodz, Tamka 12, 91-403, Lodz, Poland
| | - Renata Wietecha-Posłuszny
- Laboratory for Forensic Chemistry, Department of Analytical Chemistry, Faculty of Chemistry, Jagiellonian University, Gronostajowa 2, 30-387, Krakow, Poland.
| | - Lukasz Poltorak
- Electrochemistry@Soft Interfaces Team, Department of Inorganic and Analytical Chemistry, Faculty of Chemistry, University of Lodz, Tamka 12, 91-403, Lodz, Poland.
| |
Collapse
|
3
|
Heidari H, Sadi S. Hydrophobic deep eutectic solvent‐based microextraction method for the simultaneous extraction of two benzodiazepines from saliva samples before determination by 96‐well microplates‐based spectrophotometer with the aid of chemometrics. SEPARATION SCIENCE PLUS 2022. [DOI: 10.1002/sscp.202200060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Affiliation(s)
- Hassan Heidari
- Department of Chemistry Azarbaijan Shahid Madani University Tabriz Iran
| | - Sevda Sadi
- Department of Chemistry Azarbaijan Shahid Madani University Tabriz Iran
| |
Collapse
|
4
|
Ahmadi M, Mokhtari A, Bahlakeh G, Karimian H. Flow Injection Chemiluminescence Determination of Ethion and Computational Investigation of the Adsorption Process on Molecularly Imprinted Polymerized High Internal Phase Emulsion. LUMINESCENCE 2022; 37:1514-1523. [PMID: 35816014 DOI: 10.1002/bio.4325] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Revised: 05/19/2022] [Accepted: 06/20/2022] [Indexed: 11/09/2022]
Abstract
The lack of sufficient selectivity is the main limitation of chemiluminescence (CL) methods; because the CL reagent is not restricted to a specific analyte. This study investigated the preconcentration and determination of ethion by a flow injection CL (FIA-CL) method using a molecularly imprinted poly high internal phase emulsion (MIP-polyHIPE) adsorbent. Preliminary studies showed that ethion could be determined with high sensitivity in the Ru (bipy)3 2+ -acidic Ce (IV) CL system. A MIP-polyHIPE adsorbent was synthesized and used for preconcentration to increase the selectivity and sensitivity of the method. The adsorption of ethion on the adsorbent was investigated using density functional theory (DFT) and molecular dynamics (MD), UV-Vis and FTIR spectrophotometry and liquid chromatography-tandem mass spectrometry (LC-MS-MS). Response surface methodology (RSM) and central composite design (CCD) were used to find optimized concentrations of variables. The linear dynamic range (LDR) and limit of detection (LOD) for ethion in the FIA-CL method were calculated 1.0✕10-9 -2.0✕10-7 and 6.0✕10-10 mol L-1 , respectively. The percentage of relative standard deviation for 5 repetitive measurements of 5.0⨯10-8 mol L-1 ethion was 4.2%. The proposed method was successfully used to separate and preconcentrate ethion from drinking and surface water sources.
Collapse
Affiliation(s)
- Maryam Ahmadi
- Department of Chemistry, Faculty of Sciences, Golestan University, Gorgan, Iran
| | - Ali Mokhtari
- Department of Chemistry, Faculty of Sciences, Golestan University, Gorgan, Iran
| | - Ghasem Bahlakeh
- Department of Chemical Engineering, Faculty of Engineering, Golestan University, Aliabad Katoul, Iran
| | - Hossein Karimian
- Department of Chemical Engineering, Faculty of Engineering, Golestan University, Aliabad Katoul, Iran
| |
Collapse
|