1
|
Puthattayil ZB, Moore GP, Tang K, Huneault-Purney N, Lawrence SL. Evaluating the impact of CPAP weaning procedures on total days on nasal CPAP: A retrospective chart review. J Neonatal Perinatal Med 2021; 14:537-546. [PMID: 33523028 DOI: 10.3233/npm-200625] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND There is no consensus on how to wean infants from Nasal Continuous Positive Airway Pressure (NCPAP). We hypothesized that ceasing NCPAP abruptly would decrease the duration required, compared with a gradual wean. METHODS This retrospective chart review included preterm infants requiring NCPAP for over 48 hours. Cohort1 weaned NCPAP by cycling on and off, while cohort 2 ceased NCPAP abruptly. The primary outcome was total days on NCPAP. Secondary outcomes included rate of bronchopulmonary dysplasia, weight gain, duration of hospital stay, and compliance with the use of stability criteria. RESULTS 81 infants met inclusion criteria in cohort one, and 89 in cohort two. Median days on NCPAP were 17.0 and 11.0 days, respectively, not significant. There was no significant difference in secondary outcomes. CONCLUSIONS There was no significant association between the two NCPAP weaning protocols and the outcomes studied.
Collapse
Affiliation(s)
- Z B Puthattayil
- Department of Pediatrics, Division of Neonatology, Children's Hospital of Eastern Ontario, Ottawa, Ontario, Canada.,Department of Obstetrics, Gynecology and Newborn Care, Division of Neonatology, The Ottawa Hospital, General Campus, Ottawa, Ontario, Canada
| | - G P Moore
- Department of Pediatrics, Division of Neonatology, Children's Hospital of Eastern Ontario, Ottawa, Ontario, Canada.,Department of Obstetrics, Gynecology and Newborn Care, Division of Neonatology, The Ottawa Hospital, General Campus, Ottawa, Ontario, Canada
| | - K Tang
- Clinical Research Unit, Children's Hospital of Eastern Ontario Research Institute (CHEO RI)
| | - N Huneault-Purney
- Department of Obstetrics, Gynecology and Newborn Care, Division of Neonatology, The Ottawa Hospital, General Campus, Ottawa, Ontario, Canada
| | - S L Lawrence
- Department of Pediatrics, Division of Neonatology, Children's Hospital of Eastern Ontario, Ottawa, Ontario, Canada.,Department of Obstetrics, Gynecology and Newborn Care, Division of Neonatology, The Ottawa Hospital, General Campus, Ottawa, Ontario, Canada
| |
Collapse
|
2
|
Habas F, Durand S, Milési C, Mesnage R, Combes C, Gavotto A, Picaud JC, Cambonie G. 15-Year trends in respiratory care of extremely preterm infants: Contributing factors and consequences on health and growth during hospitalization. Pediatr Pulmonol 2020; 55:1946-1954. [PMID: 32353220 DOI: 10.1002/ppul.24774] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/18/2020] [Accepted: 04/01/2020] [Indexed: 12/20/2022]
Abstract
OBJECTIVES To review 15-year trends in respiratory care of extremely preterm infants managed in a tertiary perinatal center; to identify the factors contributing to their evolution; and to determine whether these changes had an impact on infant mortality, severe morbidity, and growth. METHODS Retrospective cohort study of infants born at 23 to 26 weeks' gestation between 2003 and 2017. Changes in respiratory care were assessed in three 5-year periods. Logistic regression was used to examine the factors associated with prolonged duration (ie, greater than the median) of invasive mechanical ventilation (IMV), noninvasive ventilation (NIV), and overall respiratory support (ORS), and those associated with adequate weight and head circumference growth. RESULTS Of the 396 actively treated neonates, 268 (68%) survived to discharge. Between the first and third periods, IMV duration decreased from 22 (6-37) to 4 (1-14.0) days (P < .001), that of NIV increased from 24 (14-34) to 56 (44-66) days (P < .001), and that of ORS from 50 (34-68) to 63 (52-77) days (P < .001). Study period (2003-2007 vs 2013-2017) was the main factor associated with prolonged IMV (P < .001). Use of high-flow nasal cannula was the main factor associated with prolonged NIV (P = .02) and ORS (P = .02). NIV duration was associated with adequate postnatal weight (P = .003) and head circumference (P = .03) growth. Severe morbidities in survivors, including bronchopulmonary dysplasia, and survival at hospital discharge were comparable across the study periods. CONCLUSIONS Respiratory management was characterized by a marked reduction in IMV. NIV withdrawal protocols are necessary to limit ORS duration while respecting postnatal growth requirements.
Collapse
Affiliation(s)
- Flora Habas
- Department of Neonatal Medicine and Pediatric Intensive Care, Arnaud de Villeneuve Hospital, Montpellier University Hospital Center, Montpellier, France
| | - Sabine Durand
- Department of Neonatal Medicine and Pediatric Intensive Care, Arnaud de Villeneuve Hospital, Montpellier University Hospital Center, Montpellier, France
| | - Christophe Milési
- Department of Neonatal Medicine and Pediatric Intensive Care, Arnaud de Villeneuve Hospital, Montpellier University Hospital Center, Montpellier, France
| | - Renaud Mesnage
- Department of Neonatal Medicine and Pediatric Intensive Care, Arnaud de Villeneuve Hospital, Montpellier University Hospital Center, Montpellier, France
| | - Clémentine Combes
- Department of Neonatal Medicine and Pediatric Intensive Care, Arnaud de Villeneuve Hospital, Montpellier University Hospital Center, Montpellier, France
| | - Arthur Gavotto
- Department of Neonatal Medicine and Pediatric Intensive Care, Arnaud de Villeneuve Hospital, Montpellier University Hospital Center, Montpellier, France
| | - Jean-Charles Picaud
- Department of Neonatal Medicine, Croix-Rousse Hospital, Lyon University Hospital Center, Lyon, France
| | - Gilles Cambonie
- Department of Neonatal Medicine and Pediatric Intensive Care, Arnaud de Villeneuve Hospital, Montpellier University Hospital Center, Montpellier, France
| |
Collapse
|
3
|
Nour I, Abdel‐Hady H. The ideal strategy of weaning from nasal continuous positive airway pressure in preterm infants: are we there yet? Acta Paediatr 2019; 108:575. [PMID: 30585349 DOI: 10.1111/apa.14673] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Affiliation(s)
- Islam Nour
- Department of Pediatrics/Neonatology Mansoura University Children's Hospital Mansoura Egypt
| | - Hesham Abdel‐Hady
- Department of Pediatrics/Neonatology Mansoura University Children's Hospital Mansoura Egypt
| |
Collapse
|
4
|
Comparison of sprinting vs non-sprinting to wean nasal continuous positive airway pressure off in very preterm infants. J Perinatol 2018; 38:164-168. [PMID: 29072676 DOI: 10.1038/jp.2017.161] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/09/2017] [Revised: 08/11/2017] [Accepted: 08/30/2017] [Indexed: 11/08/2022]
Abstract
OBJECTIVE Though nasal continuous positive airway pressure (NCPAP) is commonly used for non-invasive neonatal respiratory support, the optimal method of weaning NCPAP is not established. In this prospective, two-center randomized control trial we hypothesize that gradually increasing spontaneous breathing time off NCPAP increases successful weaning from NCPAP in infants born <31 weeks gestational age. STUDY DESIGN Infants were randomized to one of the two NCPAP weaning protocols, a sprinting, that is, gradually increasing spontaneous breathing time off CPAP, protocol vs a non-sprinting (weaning pressure down) protocol. RESULT Eighty-six infants were enrolled in one of the two study groups. Thirty-one infants (77%) in the sprinting group and 30 (75%) in the non-sprinting group were successfully weaned off NCPAP at the first attempt (P>0.05). It took 1.3 (1 to 1.75) (median (IQR)) attempts and 7 (7 to 7) days to wean NCPAP off in the sprinting group vs 1.3 (1 to 1.75) attempts and 7 (7 to 10) days in the non-sprinting group (P>0.05). Additionally, no differences in the secondary outcomes of bronchopulmonary dysplasia, severe retinopathy of prematurity (⩾stage 3), periventricular leukomalacia and length of stay were noted between the two groups. CONCLUSION Weaning NCPAP via sprinting or non-sprinting protocol is comparable, not only for successful weaning but also for the occurrence of common neonatal morbidities that impact the long-term outcome in premature infants (ClinicalTrials.gov number, NCT02819050).
Collapse
|
5
|
Sudden versus gradual pressure wean from Nasal CPAP in preterm infants: a randomized controlled trial. J Perinatol 2017; 37:662-667. [PMID: 28230835 PMCID: PMC5446290 DOI: 10.1038/jp.2017.10] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/25/2016] [Revised: 01/03/2017] [Accepted: 01/17/2017] [Indexed: 11/08/2022]
Abstract
OBJECTIVE In preterm infants, nasal continuous positive airway pressure (NCPAP) is widely used for treatment of respiratory distress syndrome. However, the strategies for successfully weaning infants off NCPAP are still not well defined and there remains considerable variation between the methods. The objective of this study is to determine whether gradual weaning of NCPAP pressure is more successful than sudden weaning off NCPAP to room air. STUDY DESIGN A randomized controlled trial was conducted in a level 3 neonatal intensive care unit on 70 preterm neonates who were born between 26 and 32 weeks gestation and required NCPAP for at least 48 h. When infants were stable on NCPAP at 0.21 FiO2 and 5 cm H2O positive end expiratory pressure, neonates were randomized to the gradual wean group (reduction in pressure by 1 cm every 8 h until 3 cm H20 was reached) or to sudden wean group (one time NCPAP removal to room air). The primary outcome was a success at the first trial to wean to room air. Secondary outcomes were a number of trials, and weight and postmenstrual age (PMA) at the time of successful wean. Total number of days on NCPAP and length of stay (LOS) in the hospital were also compared between the groups. RESULTS Of the 70 infants included in the study, 35 were randomized to sudden group and 33 infants to gradual group (2 excluded for protocol deviation). In sudden and gradual groups, 14 and 22 infants, respectively, were weaned successfully in the first attempt (P=0.03). The infants were successfully weaned at 32.7±1.7 weeks versus 33.1±2.4 weeks (P=0.39) PMA and at a weight of 1651±290 g versus 1589±398 g (P=0.46) in the sudden and gradual groups, respectively. The total number of days on NCPAP was 27±19 days versus 32±24 days (P=0.38) and LOS was 63±25 days versus 63±22 days (P=0.99) in the sudden and gradual groups, respectively. CONCLUSIONS Gradual weaning method was more successful as compared to sudden weaning method in the initial trial off NCPAP. There was no difference in the PMA, weight at the time of successful wean, total days on NCPAP and LOS between the two groups.
Collapse
|
6
|
Abstract
Continuous positive airway pressure (CPAP) has been used for respiratory support in premature infants for more than 40 years and is now a cornerstone of modern neonatal care. Clinical research on CPAP has primarily focused on understanding which devices and pressure sources best implement this therapy. In contrast, less research has examined the optimal duration over which CPAP is administered. We review this aspect of CPAP therapy.
Collapse
|
7
|
Heath Jeffery RC, Broom M, Shadbolt B, Todd DA. CeasIng Cpap At standarD criteriA (CICADA): Implementation improves neonatal outcomes. J Paediatr Child Health 2016; 52:321-6. [PMID: 27124841 DOI: 10.1111/jpc.13087] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/12/2015] [Revised: 08/14/2015] [Accepted: 09/06/2015] [Indexed: 11/28/2022]
Abstract
BACKGROUND A previous randomised controlled trial (RCT) in babies born < 30 weeks gestation found the so-called CICADA method (ceasing continuous positive airways pressure (CPAP) with a view to remain off rather than slow weaning) significantly reduced CPAP time. Post-RCT we introduced the CICADA method and evaluated whether the improved outcomes of the CICADA method during the RCT were replicated in clinical practice. AIM The aim of the study is to compare cardio-respiratory outcomes in PBs < 30 weeks GA over three epochs: (i) pre RCT, (ii) during RCT and (iii) post RCT implementation. METHODS The study used prospective data to compare baseline characteristics and cardio-respiratory outcomes over the three epochs. RESULTS There were 270/393(69%) PBs < 30 weeks GA who fulfilled the inclusion criteria over the three epochs. No significant differences were found in GA or birthweight between the three epochs (27.9 ± 1.3, 27.7 ± 1.4, 28.0 ± 1.3 (weeks ± 1 standard deviation); and 1100 ± 252, 1086 ± 251, 1094 ± 320 (grams ± 1 standard deviation)). There were significant decreases in CPAP days and corrected GA to cease CPAP post implementation (20.5 ± 2.1, 21.1 ± 2.1, 16.5 ± 1.8 (days ± SE); P = 0.006 and 33.3 ± 0.4, 33.5 ± 0.4, 32.6 ± 0.4 (weeks ± SE); P = 0.01). Compared with the pre RCT epoch, there were significant reductions in patent ductus arteriosus (36/78 (46%), 33/87 (37%), 18/103 (17%); P < 0.001) and chronic lung disease (40/78 (51%), 19/87 (21%), 30/103 (29%); P < 0.001). CONCLUSIONS CPAP time, corrected GA to cease CPAP, patent ductus arteriosus and chronic lung disease significantly reduced following the introduction of the CICADA method. Early cessation of CPAP expedites the transition from neonatal intensive care to special care.
Collapse
Affiliation(s)
| | | | - Bruce Shadbolt
- Australian National University Medical School, Canberra.,Centre for Advances in Epidemiology and IT, Canberra Hospital Garran, Canberra, Australian Capital Territory, Australia
| | - David A Todd
- Australian National University Medical School, Canberra.,Department of Neonatology, Centenary Hospital, Canberra
| |
Collapse
|
8
|
Greenough A, Lingam I. Invasive and non-invasive ventilation for prematurely born infants - current practice in neonatal ventilation. Expert Rev Respir Med 2016; 10:185-92. [PMID: 26698269 DOI: 10.1586/17476348.2016.1135741] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Non-invasive techniques, include nasal continuous positive airways pressure (nCPAP), nasal intermittent positive pressure ventilation (NIPPV) and heated, humidified, high flow cannula (HHFNC). Randomised controlled trials (RCTs) of nCPAP versus ventilation have given mixed results, but one demonstrated fewer respiratory problems during infancy. Meta-analysis demonstrated NIPPV rather than nCPAP provided better support post extubation. After extubation or initial support HHFNC has similar efficacy to CPAP. Invasive techniques include those that synchronise inflations with the patient's respiratory efforts. Assist control/ synchronised intermittent mandatory ventilation compared to non triggered modes only reduce the duration of ventilation. Further data are required to determine the efficacy of proportional assist ventilation and neurally adjusted ventilatory assist. Other techniques aim to minimise volutrauma. RCTs of volume targeted ventilation demonstrated reductions in BPD and respiratory medication usage at follow-up. Prophylactic high frequency oscillatory ventilation does not reduce BPD, but is associated with superior lung function at school age.
Collapse
Affiliation(s)
- Anne Greenough
- a Division of Asthma, Allergy and Lung Biology, MRC & Asthma UK Centre in Allergic, Mechanisms of Asthma , King's College London , London , UK.,b NIHR Biomedical Research Centre , Guy's and St Thomas' NHS Foundation Trust and King's College London , London , UK
| | - Ingran Lingam
- c Neonatal Intensive Care Centre , King's College Hospital NHS Foundation Trust , London , UK
| |
Collapse
|
9
|
CeasIng Cpap At standarD criteriA (CICADA): predicting a successful outcome. Eur J Pediatr 2016; 175:81-7. [PMID: 26231684 DOI: 10.1007/s00431-015-2603-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/26/2015] [Revised: 07/16/2015] [Accepted: 07/20/2015] [Indexed: 10/23/2022]
Abstract
UNLABELLED This is a retrospective analysis of a multicentre randomised controlled trial (RCT) where we concluded that CeasIng Cpap At standerD criteriA (CICADA) in premature babies (PBs) <30 weeks gestational age (GA) was the significantly better method of ceasing CPAP. To identify factors that may influence the number of attempts to cease CPAP, we reviewed the records of 50 PBs from the RCT who used the CICADA method. PBs were grouped according to number of attempts to cease CPAP (fast group ≤2 attempts and slow group >2 attempts to cease CPAP). There were 26 (fast group) and 24 (slow group) PBs included in the analysis. Results showed significant differences in mean GA (27.8 ± 0.3 vs 26.9 ± 0.3 [weeks ± SE], p = 0.03) and birth weight ([Bwt]; 1080 ± 48.8 vs 899 ± 45.8 [grams ± SE], p = 0.01) between groups. Significantly fewer PBs in the fast group had a patent ductus arteriosus (PDA) compared to the slow group (5/26 (19.2%) vs 13/24 (54.2 %), p = 0.02). Bwt was a significant negative predictor of CPAP duration (r = -0.497, p = 0.03) and CPAP ceasing attempts (r = -0.290, p = 0.04). CONCLUSION PBs with a higher GA and Bwt without a PDA ceased CPAP earlier using the CICADA method. Bwt was better than GA for predicting CPAP duration and attempts to cease CPAP. WHAT IS KNOWN Our previous studies showed that CeasIng Cpap At standarD criteriA (CICADA) significantly reduces CPAP time, oxygen requirements and caffeine use. Some PBs however using the CICADA method required >2 attempts to cease CPAP ('slow CICADA' group). WHAT IS NEW PBs in the 'fast CICADA' group (<3 attempts to cease CPAP) (a) have longer gestational age and higher birth weight, (b) shorter mechanical ventilation and (c) lower incidence of patent ductus arteriosus. Attempts to cease CPAP decreased by 0.5 times per 1 week increase in GA and 0.3 times per 100-g increase in birth weight for PBs <30 weeks gestation.
Collapse
|
10
|
Abdel-Hady H, Shouman B, Nasef N. Weaning preterm infants from continuous positive airway pressure: evidence for best practice. World J Pediatr 2015; 11:212-8. [PMID: 25846068 DOI: 10.1007/s12519-015-0022-6] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/26/2014] [Accepted: 11/10/2014] [Indexed: 11/29/2022]
Abstract
BACKGROUND Nasal continuous positive airway pressure (NCPAP) is frequently used in preterm infants. However, there is no consensus on when and how to wean them from NCPAP. DATA SOURCES Based on recent publications, we have reviewed the criteria of readiness-to-wean and factors affecting weaning success. A special focus is placed on the methods of weaning from NCPAP in preterm infants. RESULTS Practical points of when and how to wean from NCPAP in preterm infants are explained. Preterm infants are ready to be weaned from NCPAP when they are stable on a low NCPAP pressure with no (or minimal) oxygen requirement. Methods used to wean from NCPAP include: sudden weaning of NCPAP, gradual decrease of NCPAP pressure, graded-timeoff NCPAP (cycling), weaning to high or low flow nasal cannula, and a combination of these methods. The best strategy for weaning is yet to be determined. Cyclingoff NCPAP increases the duration of NCPAP and length of hospital stay without beneficial effect on success of weaning. Gradual decrease of NCPAP pressure is more physiological and better tolerated than cycling-off NCPAP. CONCLUSION Further studies are needed to reach a consensus regarding the optimal timing and the best method for weaning from NCPAP in preterm infants.
Collapse
Affiliation(s)
- Hesham Abdel-Hady
- Neonatal Intensive Care Unit, Mansoura University Children's Hospital, Mansoura, Egypt,
| | | | | |
Collapse
|
11
|
Amatya S, Rastogi D, Bhutada A, Rastogi S. Weaning of nasal CPAP in preterm infants: who, when and how? a systematic review of the literature. World J Pediatr 2015; 11:7-13. [PMID: 25557597 PMCID: PMC5418127 DOI: 10.1007/s12519-014-0535-4] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/27/2014] [Accepted: 11/28/2014] [Indexed: 10/24/2022]
Abstract
BACKGROUND There is increased use of early nasal continuous positive airway pressure (NCPAP) to manage respiratory distress in preterm infants but optimal methods and factors associated with successful wean are not well defined. A systematic review was performed to define the corrected gestational age (CGA), weight to wean NCPAP and the methods associated with successful weaning of the NCPAP among preterm infants, along with factors affecting it. METHODS Searches were made of PubMed using the keywords-NCPAP, CPAP, weaning, withdrawal, preterm, and infants from its inception to January 1st, 2014, for studies in all languages but limited to humans. Previous reviews (including cross references) were also searched. We included all randomized and quasi-randomized controlled trials where preterm neonates were randomized to different NCPAP weaning strategies. Details of CGA, weight and methods used for weaning NCPAP were extracted along with factors which affect its withdrawal. RESULTS Seven studies met the search criteria. The successful wean was at 32 to 33 weeks CGA and at 1600 g. Three different methods were used for weaning were sudden, gradual pressure wean and gradual graded time off wean. Criteria for readiness, success and failure to wean were defined. Factors affecting successful weaning were intubation, anemia, infection and gastro-esophageal reflux. CONCLUSIONS The successful wean was at 32 to 33 weeks CGA and 1600 g. Criteria for readiness, success and failure to wean are well defined. Sudden weaning may be associated with a shorter weaning time. Future trials are needed comparing weaning methods using defined criteria for readiness and success of NCPAP wean and stratify the results by gestational age and birth weight.
Collapse
Affiliation(s)
- Shaili Amatya
- Division of Neonatology, Maimonides Infants & Children’s Hospital, 4802 Tenth Ave, K-113, Brooklyn NY 11219, USA
| | - Deepa Rastogi
- Division of Neonatology, Maimonides Infants & Children’s Hospital, 4802 Tenth Ave, K-113, Brooklyn NY 11219, USA
| | - Alok Bhutada
- Division of Neonatology, Maimonides Infants & Children’s Hospital, 4802 Tenth Ave, K-113, Brooklyn NY 11219, USA
| | - Shantanu Rastogi
- Children’s Hospital at Montefiore, Albert Einstein College of Medicine, Bronx, NY 10467, USA
| |
Collapse
|
12
|
Selected Literature Watch. JOURNAL OF CAFFEINE RESEARCH 2014. [DOI: 10.1089/jcr.2014.1243] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|