1
|
Gaetani M, Kleiboer S, Kissoon R, Middaugh K, Parshuram CS. Vascular access devices and associated complications in paediatric critical care: A prospective cohort study. PLoS One 2024; 19:e0309650. [PMID: 39446780 PMCID: PMC11500871 DOI: 10.1371/journal.pone.0309650] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2023] [Accepted: 08/15/2024] [Indexed: 10/26/2024] Open
Abstract
BACKGROUND Though 60-80% of hospitalized patients have an intravascular device placed during hospitalization, there is a substantial risk of complication related to the placement, maintenance and removal of these devices. The objectives of this study were to describe vascular access device use, device complications and lumen dysfunction. METHODS An observational cohort study was conducted over a 4.5 years period, in two quaternary, university-affiliated paediatric intensive care units (ICU). Eligible patients were admitted to either the paediatric or cardiac ICU and had one or more vascular access devices in-situ at the time of enrolment. Vascular access devices were defined as any external connection directly into the circulation including peripheral and central veins, arteries or bone marrow. Consistent with practice in the studied ICUs removal of peripheral catheters was regarded as due to dysfunction or complication. RESULTS 220 patients, 683 devices and 924 lumens were observed. The device complication rate was 21% and the lumen complication rate was 25%. The median duration without complication was 18 days for arterial catheters, 14 days for central venous catheters; 13 days for peripherally inserted central catheters and 4 days for peripheral intravenous catheters. On one third of all patient days, the volume of fluid administered to maintain VADs was equal to or greater than 20% of the total hourly total fluid intake. CONCLUSION Approximately 1 in 5 vascular devices had one or more complications in ICU, most devices continued to be used without removal, and some complications resolved. The implications of the fluids infused to maintain device function warrants further study, as do strategies to resolve or limit the their complications in children.
Collapse
Affiliation(s)
- Melany Gaetani
- Child Health Evaluative Sciences, The Research Institute Hospital for Sick Children, Toronto, Ontario, Canada
- Departments of Paediatrics and Health Policy, Management and Evaluation, University of Toronto, Toronto, Canada
- Faculty of Medicine, Interdepartmental Division of Critical Care Medicine, University of Toronto, Toronto, Ontario, Canada
- Department of Critical Care Medicine, The Hospital for Sick Children, Toronto, Ontario, Canada
- Department of Paediatrics, The Hospital for Sick Children, Toronto, Ontario, Canada
- Center for Safety Research, Toronto, Ontario, Canada
| | | | | | - Kristen Middaugh
- Child Health Evaluative Sciences, The Research Institute Hospital for Sick Children, Toronto, Ontario, Canada
- Department of Critical Care Medicine, The Hospital for Sick Children, Toronto, Ontario, Canada
- Center for Safety Research, Toronto, Ontario, Canada
| | - Christopher S. Parshuram
- Child Health Evaluative Sciences, The Research Institute Hospital for Sick Children, Toronto, Ontario, Canada
- Departments of Paediatrics and Health Policy, Management and Evaluation, University of Toronto, Toronto, Canada
- Faculty of Medicine, Interdepartmental Division of Critical Care Medicine, University of Toronto, Toronto, Ontario, Canada
- Department of Critical Care Medicine, The Hospital for Sick Children, Toronto, Ontario, Canada
- Department of Paediatrics, The Hospital for Sick Children, Toronto, Ontario, Canada
- Center for Safety Research, Toronto, Ontario, Canada
| |
Collapse
|
2
|
Haskey E, Maund V, Allerton F, Browse B, Heard C, O'Donnell C, Davison K, Hertel C, Booth E, Lawrence S, Dever E, Bowe L, Taylor H, Hall K, Trimble K, Junior M, Fennell C, Stevenson N, Sterritt A, Penn E, Nowell L, Collins A, Jones E, Scudder C. Placement, management and complications associated with peripheral intravenous catheter use in UK small animal practice. J Small Anim Pract 2024. [PMID: 39238283 DOI: 10.1111/jsap.13782] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2023] [Revised: 07/01/2024] [Accepted: 08/07/2024] [Indexed: 09/07/2024]
Abstract
OBJECTIVES To describe the techniques for preparation and placement of peripheral intravenous catheters (PIVCs), to describe the complications associated with PIVCs, and to identify factors associated with PIVC complications in small animal practice in the United Kingdom. MATERIALS AND METHODS A prospective multicentre observational study was undertaken between January 2022 and January 2023. Data collected included patient information, information regarding the placement and maintenance of PIVCs, and PIVC complications, from privately owned cats and dogs presenting to veterinary institutes in the United Kingdom. Patients required a PIVC to be placed as part of their care and the PIVC was anticipated to be in situ for >24 hours to be eligible for PIVC complication analysis. RESULTS A total of 19 institutes recorded data regarding 382 PIVCs, with 325 (85.1%) placed in dogs and 57 (14.9%) in cats. The most common reasons for placement were to administer intravenous fluid therapy (74.3%) and intravenous medications (71.7%). There were 102 of 382 (26.7%) PIVCs associated with a complication, with limb swelling/suspected phlebitis in 44 of 382 (11.5%) and PIVC dislodgement/patient interference in 30 of 382 (7.9%) PIVCs. Factors associated with increased risk of complication were more than 1 attempt to place the PIVC, a second or subsequent PIVC being placed during hospitalisation, flush frequency different than every 1 to 24 hours, and flush solution with compound sodium lactate. CLINICAL SIGNIFICANCE Veterinary professionals must be vigilant when monitoring a patient with a PIVC in situ, particularly if a PIVC is associated with one of the aforementioned factors of increased likelihood of complication.
Collapse
Affiliation(s)
- E Haskey
- Clinical Sciences and Services, Royal Veterinary College, Potters Bar, UK
| | - V Maund
- Willows Veterinary Centre and Referral Service, Solihull, UK
| | - F Allerton
- Willows Veterinary Centre and Referral Service, Solihull, UK
| | - B Browse
- Cave Veterinary Specialists, Wellington, UK
| | - C Heard
- Highcroft Veterinary Specialists, Bristol, UK
| | | | - K Davison
- Paragon Veterinary Referrals, Wakefield, UK
| | - C Hertel
- Quarry Veterinary Group, Shrewsbury, UK
| | - E Booth
- Quarry Veterinary Group, Shrewsbury, UK
| | - S Lawrence
- Davies Veterinary Specialists, Hertfordshire, UK
| | - E Dever
- Kentdale Referrals, Milnthorpe, UK
| | - L Bowe
- Kentdale Referrals, Milnthorpe, UK
| | - H Taylor
- Dick White Referrals, Cambridgeshire, UK
| | - K Hall
- Dick White Referrals, Cambridgeshire, UK
| | - K Trimble
- Wear Referrals Veterinary Specialist & Emergency Hospital, Stockton-on-Tees, UK
| | - M Junior
- Wear Referrals Veterinary Specialist & Emergency Hospital, Stockton-on-Tees, UK
| | - C Fennell
- Southfields Veterinary Specialists, Essex, UK
| | | | - A Sterritt
- Taverham Veterinary Hospital, Norwich, UK
| | - E Penn
- Willows Veterinary Group, Cheshire, UK
| | | | | | - E Jones
- North Wales Veterinary Referrals, Buckley, UK
| | - C Scudder
- Clinical Sciences and Services, Royal Veterinary College, Potters Bar, UK
| |
Collapse
|
3
|
Indarwati F, Munday J, Keogh S. Peripheral intravenous catheter insertion, maintenance and outcomes in Indonesian paediatric hospital settings: A point prevalence study. J Pediatr Nurs 2023; 73:106-112. [PMID: 37659338 DOI: 10.1016/j.pedn.2023.08.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Revised: 08/09/2023] [Accepted: 08/09/2023] [Indexed: 09/04/2023]
Abstract
PURPOSE This study aimed to assess peripheral intravenous catheter use, maintenance practices, and outcomes of paediatric patients in a developing country setting. DESIGN AND METHODS A point prevalence survey using validated checklist was conducted between March and April 2022 in ten hospitals in Indonesia. A total number of 478 participants were approached during the audit. Data were obtained from site observation and medical records. RESULTS Of the 386 patients surveyed, >90% (362) had one catheter in-situ. The catheters were mostly inserted by nurses (331, 86%), primarily in the dorsum of the hand (207, 54%) with the purpose of delivering intravenous infusions and medications (367, 95%). Simple transparent dressings (176, 46%) with splint and bandage (295, 76%) were predominantly used for securement methods. Insertion sites were not visible for 182 (47%) patients, and 151 (40%) of daily care practices were poorly documented. Complications were documented in the medical record for 166 (43%) catheters. Adjusted analysis indicated that patient diagnosis, ward, catheter size, location, dressings, infusate, and flushing administration were significantly associated with complications. CONCLUSIONS Findings indicate that issues related to paediatric intravenous catheter complications in Indonesia are comparable to developed country settings. Ongoing surveillance is important to evaluate the management practices to benchmark against guidelines, optimise patient safety, and improve outcomes. PRACTICE IMPLICATIONS Results demonstrate low and middle-income countries face similar challenges with catheter insertion and care. The study indicates the importance of applying vascular access needs assessments, providing training for inserters, identifying optimum dressing methods, and optimising documentation.
Collapse
Affiliation(s)
- Ferika Indarwati
- Queensland University of Technology (QUT), School of Nursing and Centre for Healthcare Transformation, Brisbane, Queensland, Australia; School of Nursing, Faculty of Medicine and Health Sciences, Universitas Muhammadiyah Yogyakarta, Yogyakarta, Indonesia; Alliance of Vascular Access Teaching and Research Group, Griffith University, Queensland, Australia.
| | - Judy Munday
- Queensland University of Technology (QUT), School of Nursing and Centre for Healthcare Transformation, Brisbane, Queensland, Australia; Faculty of Health and Nursing Sciences, University of Agder, Grimstad, Norway.
| | - Samantha Keogh
- Queensland University of Technology (QUT), School of Nursing and Centre for Healthcare Transformation, Brisbane, Queensland, Australia; Nursing and Midwifery Research Centre, Royal Brisbane and Women's Hospital, Brisbane, Queensland, Australia; Alliance of Vascular Access Teaching and Research Group, Griffith University, Queensland, Australia.
| |
Collapse
|
4
|
Kleidon TM, Schults J, Rickard CM, Ullman AJ. Techniques and Technologies to Improve Peripheral Intravenous Catheter Outcomes in Pediatric Patients: Systematic Review and Meta-Analysis. J Hosp Med 2021; 16:742-750. [PMID: 34797998 DOI: 10.12788/jhm.3718] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/17/2021] [Accepted: 10/06/2021] [Indexed: 11/20/2022]
Abstract
OBJECTIVE Insertion and function of pediatric peripheral intravenous catheters (PIVCs) present challenges. We systematically reviewed techniques and technologies to improve PIVC outcomes (first-time insertion success, overall insertion success, time to insertion, dwell time, failure, and complications). DATA SOURCES Cochrane Central Register of Controlled Trials (CONTROL), Cumulative Index to Nursing and Allied Health (CINAHL), US National Library of Medicine, and Embase. STUDY SELECTION English-language pediatric trials published post 2010 reporting PIVC outcomes. DATA EXTRACTION Following Cochrane standards, two authors screened, extracted, and critiqued study quality (Grading of Recommendations Assessment, Development and Evaluation approach) data, random effects analysis, results expressed as risk ratios (RR), mean differences (MD) and 95% CIs. RESULTS Twenty-one studies (3237 children; 3098 PIVCs) were included. First-time insertion success significantly increased with ultrasound guidance (compared with landmark insertion; RR, 1.60; 95% CI, 1.02-2.50). Use of ultrasound guidance (compared with landmark insertion) did not improve overall PIVC insertion success (RR, 1.10; 95% CI, 0.94-1.28). There was no evidence of an effect of near-infrared (compared with landmark) on first-time insertion success (RR, 1.21; 95% CI, 0.91-1.59) or number of attempts (MD, -0.65; 95% CI, -1.59 to 0.29); however, it significantly reduced PIVC insertion time (MD, -132.47; 95% CI, -166.68 to -98.26) and increased first-time insertion success in subgroup analysis of patients with difficult intravenous access (RR, 2.72; 95% CI, 1.02-7.24). LIMITATIONS Few studies per intervention, small sample sizes, and inconsistent outcome measures precluded definitive conclusions. CONCLUSIONS Ultrasound and near-infrared appear to improve pediatric PIVC insertion. High-quality studies examining the full extent of techniques and technologies are needed. Registration: CRD42020175314.
Collapse
Affiliation(s)
- Tricia M Kleidon
- Queensland Children's Hospital, Queensland, Australia
- Alliance for Vascular Access Teaching and Research Group, Griffith University, Brisbane, Australia
- The University of Queensland, Queensland, Australia
- Metro North Hospitals and Health Service, Brisbane, Australia
| | - Jessica Schults
- Queensland Children's Hospital, Queensland, Australia
- Alliance for Vascular Access Teaching and Research Group, Griffith University, Brisbane, Australia
- The University of Queensland, Queensland, Australia
- Metro North Hospitals and Health Service, Brisbane, Australia
| | - Claire M Rickard
- Queensland Children's Hospital, Queensland, Australia
- Alliance for Vascular Access Teaching and Research Group, Griffith University, Brisbane, Australia
- The University of Queensland, Queensland, Australia
- Metro North Hospitals and Health Service, Brisbane, Australia
| | - Amanda J Ullman
- Queensland Children's Hospital, Queensland, Australia
- Alliance for Vascular Access Teaching and Research Group, Griffith University, Brisbane, Australia
- The University of Queensland, Queensland, Australia
- Metro North Hospitals and Health Service, Brisbane, Australia
| |
Collapse
|
5
|
Parreira P, Vicente R, Bernardes RA, Sousa LB, Serambeque B, Costa P, Braga LM, Mónico L, Salgueiro-Oliveira A. The flushing procedure in nursing practices: A cross-sectional study with Portuguese and Brazilian nurses. Heliyon 2020; 6:e04579. [PMID: 32802977 PMCID: PMC7417889 DOI: 10.1016/j.heliyon.2020.e04579] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2020] [Revised: 06/24/2020] [Accepted: 07/27/2020] [Indexed: 11/22/2022] Open
Abstract
BACKGROUND In patients with peripheral intravenous catheters (PIVCs), performing flushing is an essential procedure to maintain catheter patency and prevent complications. These PIVC related complications can lead to premature removal and therapeutics interruption, which implies the need of a new catheterization thus increasing patient discomfort and pain. AIMS To identify nursing practices related to the flushing procedure, namely: moment(s) of the flushing; the syringe size used; the flush solution, volume and technique; the knowledge and accomplishment of the recommended standards on flushing by nurses. METHODS A cross-sectional study was conducted between July and December 2017, with Brazilian and Portuguese nurses. An online questionnaire was developed based on the international recommendations on flushing procedure. Descriptive analysis was performed. RESULTS A total of 76 nurses answered the questionnaire. The majority of nurses (84.2%) performed flushing: the most common technique used was continuous syringe pressure (31.2%), with the push-pause technique being performed by 23.4% of the nurses. Despite the majority performs flushing at four distinct moments (after the PIVC insertion, before, between and after drug delivery), there are inconsistencies in flush solution, volume, and syringe size. The most used volume to perform flushing was 5 mL, filled using normal saline. Despite this, they also recognized the omission of this procedure due to time constrains, no familiarity with the procedure and unavailable material. CONCLUSIONS This study identified that flushing procedure isn't always performed by nurses in their clinical practice. Also, several inconsistencies were observed between nurses that performed flushing, reflecting the lack of empirical evidence in this area of research.
Collapse
Affiliation(s)
- Pedro Parreira
- The Health Sciences Research Unit: Nursing (UICISA: E), Nursing School of Coimbra (ESEnfC), Coimbra, Portugal
| | - Ricardo Vicente
- The Health Sciences Research Unit: Nursing (UICISA: E), Nursing School of Coimbra (ESEnfC), Coimbra, Portugal
| | - Rafael A. Bernardes
- The Health Sciences Research Unit: Nursing (UICISA: E), Nursing School of Coimbra (ESEnfC), Coimbra, Portugal
| | - Liliana B. Sousa
- The Health Sciences Research Unit: Nursing (UICISA: E), Nursing School of Coimbra (ESEnfC), Coimbra, Portugal
| | - Beatriz Serambeque
- The Health Sciences Research Unit: Nursing (UICISA: E), Nursing School of Coimbra (ESEnfC), Coimbra, Portugal
| | - Paulo Costa
- The Health Sciences Research Unit: Nursing (UICISA: E), Nursing School of Coimbra (ESEnfC), Coimbra, Portugal
| | - Luciene M. Braga
- Department of Medicine and Nursing, Federal University of Viçosa, Viçosa, Minas Gerais, Brazil
| | - Lisete Mónico
- The Health Sciences Research Unit: Nursing (UICISA: E), Nursing School of Coimbra (ESEnfC), Coimbra, Portugal
| | - Anabela Salgueiro-Oliveira
- The Health Sciences Research Unit: Nursing (UICISA: E), Nursing School of Coimbra (ESEnfC), Coimbra, Portugal
| |
Collapse
|
6
|
Sotnikova C, Fasoi G, Efstathiou F, Kaba E, Bourazani M, Kelesi M. The Efficacy of Normal Saline (N/S 0.9%) Versus Heparin Solution in Maintaining Patency of Peripheral Venous Catheter and Avoiding Complications: a Systematic Review. Mater Sociomed 2020; 32:29-34. [PMID: 32410888 PMCID: PMC7219714 DOI: 10.5455/msm.2020.32.29-34] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2020] [Accepted: 03/06/2020] [Indexed: 01/09/2023] Open
Abstract
INTRODUCTION Heparin is a sulfated polysaccharide belonging to the glycosaminoglycan family with strong anticoagulant activity. It has been widely used to maintain intravascular catheters in patients requiring intravenous medication. It is believed that heparin prevents thrombus formation in the intravascular catheter, but since the 1980s, the necessity of the heparin solution for peripheral intravenous catheter (PIVC) flushing has been questioned in several clinical trials. According to the Institute for Safe Medication Practices (ISMP), there are four special categories of High Alert Medications (HAMs), including heparin. AIM The aim of this systematic review was to investigate the efficacy of normal saline versus heparin solution in maintaining the patency and functionality of the PIVC and avoiding complications. METHODOLOGY A systematic review using PubMed and Cochrane Library databases was conducted. Original research studies of hospitalized patients with PIVC, regardless of age, published in English, over the last decade (2009-2019) were eligible for inclusion. RESULTS The review concluded in 10 studies that met the inclusion criteria. From these studies, it appears that it is not fully documented whether the normal saline (N/S 0,9%) is superior to heparin solution (H/S) in the flushing of the PIVC for maintaining its patency and prevent complications. Researchers tend to support the use of N/S 0,9% due to safety, error avoidance, efficiency, ease of use and cost-effectiveness. Concern about the possible complications of the heparin solution was the cause of guidelines development for N/S 0,9% in countries such as Australia. CONCLUSIONS The use of normal saline seems to outweigh the heparin solution in maintaining the patency of PIVC.
Collapse
Affiliation(s)
| | - Georgia Fasoi
- Department of Nursing, University of West Attica, Athens, Greece
| | | | - Evridiki Kaba
- Department of Nursing, University of West Attica, Athens, Greece
| | - Maria Bourazani
- Department of Anesthesiology, Hellenic Anticancer Institute, Saint Savvas Hospital, Athens, Athens, Greece
| | - Martha Kelesi
- Department of Nursing, University of West Attica, Athens, Greece
| |
Collapse
|
7
|
Kleidon TM, Keogh S, Flynn J, Schults J, Mihala G, Rickard CM. Flushing of peripheral intravenous catheters: A pilot, factorial, randomised controlled trial of high versus low frequency and volume in paediatrics. J Paediatr Child Health 2020; 56:22-29. [PMID: 31033046 DOI: 10.1111/jpc.14482] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/03/2019] [Revised: 04/08/2019] [Accepted: 04/10/2019] [Indexed: 11/27/2022]
Abstract
AIM To test the feasibility of an efficacy trial comparing different flushing frequencies and volumes to reduce peripheral intravenous cannula (PIVC) failure in paediatric inpatients. METHODS Pilot, 2 × 2 factorial, randomised controlled trial comparing PIVC flushing techniques in intervention pairs: (i) low volume (3 mL) versus high volume (10 mL); and (ii) low frequency (24 hourly) versus high frequency (6 hourly). Patients were excluded if: fluids were restricted, weight < 5 kg, PIVC already in situ for >24 h or continuous infusion. The primary end-point was feasibility (eligibility, recruitment, retention, protocol adherence, missing data and sample size estimates) of a large trial. Secondary end-points were PIVC failure (composite and individual), bloodstream infection and mortality. RESULTS A total of 919 children were screened from April to November 2015, with 55 enrolled. Screening feasibility criteria were not met, mainly due to continuous infusions and PIVCs in situ >24 h or planned for imminent removal. However, 80% of eligible participants consented, 2% withdrew, protocol adherence was 100%, and there was no missing primary end-point data. PIVC failure was significantly higher (hazard ratio = 2.90, 95% confidence interval: 1.11-7.54) in the 3 mL compared to the 10 mL group. There was no difference in failure between frequency groups (hazard ratio = 0.91, 95% confidence interval: 0.36-2.33). There was no interaction effect (P = 0.22). CONCLUSION Trial feasibility proved challenging due to eligibility criteria, which could be improved with additional recruiting staff. Firm conclusions cannot be made based on this small sample, but flush volume may impact PIVC failure.
Collapse
Affiliation(s)
- Tricia M Kleidon
- Department of Anaesthetics, Queensland Children's Hospital, Brisbane, Queensland, Australia.,Alliance for Vascular Access Teaching and Research (AVATAR), Menzies Heath Institute Queensland, Griffith University, Brisbane, Queensland, Australia
| | - Samantha Keogh
- Alliance for Vascular Access Teaching and Research (AVATAR), Menzies Heath Institute Queensland, Griffith University, Brisbane, Queensland, Australia.,School of Nursing, Queensland University of Technology, Brisbane, Queensland, Australia
| | - Julie Flynn
- Alliance for Vascular Access Teaching and Research (AVATAR), Menzies Heath Institute Queensland, Griffith University, Brisbane, Queensland, Australia.,Nursing and Midwifery Research Centre, Royal Brisbane and Women's Hospital, Brisbane, Queensland, Australia.,School of Nursing and Midwifery, Griffith University, Brisbane, Queensland, Australia
| | - Jessica Schults
- Department of Anaesthetics, Queensland Children's Hospital, Brisbane, Queensland, Australia.,Alliance for Vascular Access Teaching and Research (AVATAR), Menzies Heath Institute Queensland, Griffith University, Brisbane, Queensland, Australia.,School of Nursing and Midwifery, Griffith University, Brisbane, Queensland, Australia
| | - Gabor Mihala
- Alliance for Vascular Access Teaching and Research (AVATAR), Menzies Heath Institute Queensland, Griffith University, Brisbane, Queensland, Australia.,Centre for Applied Health Economics, School of Medicine, Griffith University, Brisbane, Queensland, Australia
| | - Claire M Rickard
- Alliance for Vascular Access Teaching and Research (AVATAR), Menzies Heath Institute Queensland, Griffith University, Brisbane, Queensland, Australia.,Nursing and Midwifery Research Centre, Royal Brisbane and Women's Hospital, Brisbane, Queensland, Australia.,School of Nursing and Midwifery, Griffith University, Brisbane, Queensland, Australia
| |
Collapse
|
8
|
Hawthorn A, Bulmer AC, Mosawy S, Keogh S. Implications for maintaining vascular access device patency and performance: Application of science to practice. J Vasc Access 2019; 20:461-470. [DOI: 10.1177/1129729818820200] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Introduction:Vascular access devices are commonly inserted devices that facilitate the administration of fluids and drugs, as well as blood sampling. Despite their common use in clinical settings, these devices are prone to occlusion and failure, requiring replacement and exposing the patient to ongoing discomfort/pain, local vessel inflammation and risk of infection. A range of insertion and maintenance strategies are employed to optimize device performance; however, the evidence base for many of these mechanisms is limited and the mechanisms contributing to the failure of these devices are largely unknown.Aims/objectives:(1) To revisit existing understanding of blood, vessel physiology and biological fluid dynamics; (2) develop an understanding of the implications that different clinical practices have on vessel health, and (3) apply these understandings to vascular access device research and practice.Method:Narrative review of biomedical and bioengineering studies related to vascular access practice.Results/outcomes:Current vascular access device insertion and maintenance practice and policy are variable with limited clinical evidence to support the theoretical assumptions underpinning these regimens. This review demonstrates the physiological response to vascular access device insertion, flushing and infusion on the vein, blood components and blood flow. These appear to be associated with changes in intravascular fluid dynamics. Variable forces are at play that impact blood componentry and the endothelium. These may explain the mechanisms contributing to vascular access failure.Conclusion:This review provides an update to our current knowledge and understanding of vascular physiology and the hemodynamic response, challenging some previously held assumptions regarding vascular access device maintenance, which require further investigation.
Collapse
Affiliation(s)
- Alexandra Hawthorn
- School of Nursing, Queensland University of Technology, Brisbane, QLD, Australia
- School of Medicine, Griffith University, Brisbane, QLD, Australia
- Alliance for Vascular Access Teaching and Research (AVATAR), Menzies Health Institute Queensland, Griffith University, Brisbane, QLD, Australia
| | - Andrew C Bulmer
- School of Medicine, Griffith University, Brisbane, QLD, Australia
- Alliance for Vascular Access Teaching and Research (AVATAR), Menzies Health Institute Queensland, Griffith University, Brisbane, QLD, Australia
| | - Sapha Mosawy
- School of Medicine, Griffith University, Brisbane, QLD, Australia
| | - Samantha Keogh
- School of Nursing, Queensland University of Technology, Brisbane, QLD, Australia
- Alliance for Vascular Access Teaching and Research (AVATAR), Menzies Health Institute Queensland, Griffith University, Brisbane, QLD, Australia
| |
Collapse
|
9
|
Impact of flushing with aseptic non-touch technique using pre-filled flush or manually prepared syringes on central venous catheter occlusion and bloodstream infections in pediatric hemato-oncology patients: A randomized controlled study. Eur J Oncol Nurs 2018; 33:78-84. [DOI: 10.1016/j.ejon.2018.02.002] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2017] [Revised: 01/29/2018] [Accepted: 02/02/2018] [Indexed: 01/10/2023]
|
10
|
Marsh N, Webster J, Larson E, Cooke M, Mihala G, Rickard CM. Observational Study of Peripheral Intravenous Catheter Outcomes in Adult Hospitalized Patients: A Multivariable Analysis of Peripheral Intravenous Catheter Failure. J Hosp Med 2018; 13:83-89. [PMID: 29073316 DOI: 10.12788/jhm.2867] [Citation(s) in RCA: 102] [Impact Index Per Article: 17.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
BACKGROUND Almost 70% of hospitalized patients require a peripheral intravenous catheter (PIV), yet up to 69% of PIVs fail prior to completion of therapy. OBJECTIVE To identify risk factors associated with PIV failure. DESIGN A single center, prospective, cohort study. SETTING Medical and surgical wards of a tertiary hospital located in Queensland, Australia. PARTICIPANTS Adult patients requiring a PIV. MEASUREMENTS Demographic, clinical, and potential PIV risk factors were collected. Failure occurred if the catheter had complications at removal. RESULTS We recruited 1000 patients. Catheter failure occurred in 512 (32%) of 1578 PIVs. Occlusion/infiltration risk factors included intravenous (IV) flucloxacillin (hazard ratio [HR], 1.98; 95% confidence interval [CI], 1.19-3.31), 22-gauge PIVs (HR, 1.43; 95% CI, 1.02-2.00), and female patients (HR, 1.48; 95% CI, 1.10-2.00). Phlebitis was associated with female patients (HR, 1.81; 95% CI, 1.40-2.35), bruised insertion sites (HR, 2.16; 95% CI, 1.26-3.71), IV flucloxacillin (HR, 2.01; 95% CI, 1.26-3.21), and dominant side insertion (HR, 1.39; 95% CI, 1.09-1.77). Dislodgement risks were a paramedic insertion (HR, 1.78; 95% CI, 1.03-3.06).Each increase by 1 in the average number of daily PIV accesses was associated (HR 1.11, 95% CI 1.03-1.20)-(HR 1.14, 95% CI 1.08-1.21) with occlusion/infiltration, phlebitis and dislodgement. Additional securement products were associated with less (HR 0.32, 95% C-0.46)-(HR 0.63, 95% CI 0.48-0.82) occlusion/infiltration, phlebitis and dislodgement. CONCLUSION Modifiable risk factors should inform education and inserter skill development to reduce the currently high rate of PIV failure.
Collapse
Affiliation(s)
- Nicole Marsh
- 1Nursing & Midwifery Research Centre, Royal Brisbane and Women's Hospital, Brisbane, Queensland, Australia
- School of Nursing and Midwifery, Griffith University, Brisbane, Queensland, Australia.
- Alliance for Vascular Access Teaching and Research Group, Menzies Health Institute, Brisbane, Queensland, Australia
| | - Joan Webster
- 1Nursing & Midwifery Research Centre, Royal Brisbane and Women's Hospital, Brisbane, Queensland, Australia
- School of Nursing and Midwifery, Griffith University, Brisbane, Queensland, Australia
- School of Nursing, Queensland University of Technology, Brisbane, Queensland, Australia
| | - Emily Larson
- 1Nursing & Midwifery Research Centre, Royal Brisbane and Women's Hospital, Brisbane, Queensland, Australia
- School of Nursing and Midwifery, Griffith University, Brisbane, Queensland, Australia
- Alliance for Vascular Access Teaching and Research Group, Menzies Health Institute, Brisbane, Queensland, Australia
| | - Marle Cooke
- School of Nursing and Midwifery, Griffith University, Brisbane, Queensland, Australia
- Alliance for Vascular Access Teaching and Research Group, Menzies Health Institute, Brisbane, Queensland, Australia
| | - Gabor Mihala
- School of Nursing and Midwifery, Griffith University, Brisbane, Queensland, Australia
- Alliance for Vascular Access Teaching and Research Group, Menzies Health Institute, Brisbane, Queensland, Australia
- School of Medicine, Griffith University, Brisbane, Queensland, Australia
- Centre for Applied Health Economics, Menzies Health Institute, Brisbane, Queensland, Australia
| | - Claire M Rickard
- 1Nursing & Midwifery Research Centre, Royal Brisbane and Women's Hospital, Brisbane, Queensland, Australia
- School of Nursing and Midwifery, Griffith University, Brisbane, Queensland, Australia
- Alliance for Vascular Access Teaching and Research Group, Menzies Health Institute, Brisbane, Queensland, Australia
| |
Collapse
|
11
|
Improving outcomes of short peripheral vascular access in oncology and chemotherapy administration. J Vasc Access 2017; 18:89-96. [PMID: 28127726 DOI: 10.5301/jva.5000668] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/18/2016] [Indexed: 11/20/2022] Open
Abstract
A short peripheral intravenous catheter or cannula (PIVC) is frequently used to deliver chemotherapy in oncology practice. Although safe and easy to insert, PIVCs do fail, leading to personal discomfort for patients and adding substantially to treatment costs. As the procedure of peripheral catheterization is invasive, there is a need for greater consistency in the choice, insertion and management of short PIVCs, particularly in the oncology setting where there is a growing trend for patients to receive many different courses of IV treatment over a number of years, sometimes with only short remissions. This article reviews best practice with respect to PIVCs in cancer patients and considers the necessity for bundling these actions. Two care bundles, addressing both insertion and ongoing care and maintenance, are proposed. These have the potential to improve outcomes with the use of short PIVCs for vascular access in oncology practice.
Collapse
|
12
|
Keogh S, Flynn J, Marsh N, Mihala G, Davies K, Rickard C. Varied flushing frequency and volume to prevent peripheral intravenous catheter failure: a pilot, factorial randomised controlled trial in adult medical-surgical hospital patients. Trials 2016; 17:348. [PMID: 27456005 PMCID: PMC4960789 DOI: 10.1186/s13063-016-1470-6] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2015] [Accepted: 06/28/2016] [Indexed: 12/01/2022] Open
Abstract
Background Research has identified high failure rates of peripheral intravenous catheter (PIVC) and varied flushing practices. Methods This is a single-centre, pilot, non-masked, factorial randomised controlled trial. Participants were adults, with a PIVC of expected use ≥24 hours (n = 160), admitted to general medical or surgical wards of a tertiary referral hospital in Queensland (Australia). Patients were randomly allocated to one of four flush groups using manually prepared syringes and 0.9 % sodium chloride: 10 mL or 3 mL flush, every 24 or 6 hours. The primary endpoint was PIVC failure, a composite measure of occlusion, infiltration, accidental dislodgement and phlebitis. Results PIVC average dwell was 3.1 days. PIVC failure rates per 1000 hours were not significantly different for the volume intervention (4.84 [3 mL] versus 7.44 [10 mL], p = 0.06, log-rank). PIVC failure rates per 1000 hours were also not significantly different for the frequency intervention (5.06 [24 hour] versus 7.34 [6 hour], p = 0.05, log-rank). Cox proportional hazard regression found neither the flushing nor frequency intervention, or their interaction (p = 0.21) to be significantly associated with PIVC failure. However, female gender (hazard ratio [HR] 2.2 [1.3–3.6], p < 0.01), insertion in hand/posterior wrist (HR 1.7 [1.0–2.7], p < 0.05) and the rate per day of PIVC access (combined flushes and medication pushes) (HR 1.2 [1.1–1.4], p < 0.01) significantly predicted PIVC failure. Conclusion Neither increased flushing volume nor frequency significantly altered the risk of PIVC failure. Female gender, hand/posterior wrist placement and episodes of access (flushes and medication) may be more important. Larger, definitive trials are feasible and required. Trial registration Australian and New Zealand Clinical Trials Registry: ACTRN12615000025538. Registered on 19 January 2015.
Collapse
Affiliation(s)
- Samantha Keogh
- NHMRC Centre of Research Excellence in Nursing (NCREN), Menzies Health Institute Queensland, Griffith University, Health Sciences Building N48 170 Kessels Road, Nathan, Brisbane, Queensland, 4011, Australia. .,Centre for Clinical Nursing, Royal Brisbane and Women's Hospital, Herston, Brisbane, Queensland, Australia.
| | - Julie Flynn
- NHMRC Centre of Research Excellence in Nursing (NCREN), Menzies Health Institute Queensland, Griffith University, Health Sciences Building N48 170 Kessels Road, Nathan, Brisbane, Queensland, 4011, Australia.,Centre for Clinical Nursing, Royal Brisbane and Women's Hospital, Herston, Brisbane, Queensland, Australia
| | - Nicole Marsh
- NHMRC Centre of Research Excellence in Nursing (NCREN), Menzies Health Institute Queensland, Griffith University, Health Sciences Building N48 170 Kessels Road, Nathan, Brisbane, Queensland, 4011, Australia.,Centre for Clinical Nursing, Royal Brisbane and Women's Hospital, Herston, Brisbane, Queensland, Australia
| | - Gabor Mihala
- School of Medicine, Menzies Health Institute Queensland, Griffith University, Meadowbrook, Queensland, Australia
| | - Karen Davies
- Centre for Clinical Nursing, Royal Brisbane and Women's Hospital, Herston, Brisbane, Queensland, Australia.,School of Medicine, University of Queensland, St Lucia, Brisbane, Australia
| | - Claire Rickard
- NHMRC Centre of Research Excellence in Nursing (NCREN), Menzies Health Institute Queensland, Griffith University, Health Sciences Building N48 170 Kessels Road, Nathan, Brisbane, Queensland, 4011, Australia.,Centre for Clinical Nursing, Royal Brisbane and Women's Hospital, Herston, Brisbane, Queensland, Australia
| |
Collapse
|
13
|
Keogh S, Flynn J, Marsh N, Higgins N, Davies K, Rickard CM. Nursing and midwifery practice for maintenance of vascular access device patency. A cross-sectional survey. Int J Nurs Stud 2015. [DOI: 10.1016/j.ijnurstu.2015.07.001] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|