1
|
Vallée R, Meduri E, Vallée JN, Lallouette A, Haffane Z, Paillard A, Mansouri K, Mermoud A. Predictive biomarkers of intra-ocular pressure decrease after cataract surgery associated with trabecular washout in patients with pseudo exfoliative glaucoma. Sci Rep 2024; 14:13567. [PMID: 38866840 PMCID: PMC11169244 DOI: 10.1038/s41598-024-53893-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2023] [Accepted: 02/06/2024] [Indexed: 06/14/2024] Open
Abstract
To investigate biomarkers of intra-ocular pressure (IOP) decrease after cataract surgery with trabecular washout in pseudo-exfoliative (PEX) glaucoma. A single-center observational prospective study in PEX glaucoma patients undergoing cataract surgery with trabecular washout (Goniowash) was performed from 2018 to 2021. Age, gender, visual acuity, IOP, endothelial cell count, central corneal thickness, medications, were collected over 16-month follow-up. Multivariable binomial regression models were implemented. 54 eyes (35 subjects) were included. Mean preoperative IOP (IOPBL) was 15.9 ± 3.5 mmHg. Postoperative IOP reduction was significant at 1-month and throughout follow-up (p < 0.01, respectively). IOPBL was a predictive biomarker inversely correlated to IOP decrease throughout follow-up (p < 0.001). At 1 and 12 months of follow-up, IOP decrease concerned 31 (57.4%) and 34 (63.0%) eyes with an average IOP decrease of 17.5% (from 17.6 ± 3.1 to 14.3 ± 2.2 mmHg) and 23.0% (from 17.7 ± 2.8 to 13.5 ± 2.6 mmHg), respectively. Performance (AUC) of IOPBL was 0.85 and 0.94 (p < 0.0001, respectively), with IOPBL threshold ≥ 15 mmHg for 82.1% and 96.8% sensitivity, 84.2% and 75.0% specificity, 1.84 and 3.91 IOP decrease odds-ratio, respectively. All PEX glaucoma patients with IOPBL greater than or equal to the average general population IOP were likely to achieve a significant sustainable postoperative IOP decrease.
Collapse
Affiliation(s)
- Rodolphe Vallée
- Diagnostic and Functional Neuroradiology and Brain stimulation Department, 15-20 National Vision Hospital - Paris University Hospital Center, University of PARIS-SACLAY - UVSQ, Paris, France.
- Mathematics and Applications Laboratory (LMA), CNRS UMR7348, LRCOM i3M-DACTIMMIS, University of Poitiers, Poitiers, France.
- Glaucoma Research Center, Montchoisi Clinic, Swiss Visio, Lausanne, Switzerland.
| | - Enrico Meduri
- Glaucoma Research Center, Montchoisi Clinic, Swiss Visio, Lausanne, Switzerland
| | - Jean-Noël Vallée
- Diagnostic and Functional Neuroradiology and Brain stimulation Department, 15-20 National Vision Hospital - Paris University Hospital Center, University of PARIS-SACLAY - UVSQ, Paris, France
| | - Athena Lallouette
- Glaucoma Research Center, Montchoisi Clinic, Swiss Visio, Lausanne, Switzerland
| | - Zakarya Haffane
- Glaucoma Research Center, Montchoisi Clinic, Swiss Visio, Lausanne, Switzerland
| | - Archibald Paillard
- Glaucoma Research Center, Montchoisi Clinic, Swiss Visio, Lausanne, Switzerland
| | - Kaweh Mansouri
- Glaucoma Research Center, Montchoisi Clinic, Swiss Visio, Lausanne, Switzerland
- Ophthalmology Department, Colorado University Medical School, Denver, CO, USA
| | - André Mermoud
- Glaucoma Research Center, Montchoisi Clinic, Swiss Visio, Lausanne, Switzerland
| |
Collapse
|
2
|
Ramezani F, Nazarian M, Rezaei L. Intraocular pressure changes after phacoemulsification in pseudoexfoliation versus healthy eyes. BMC Ophthalmol 2021; 21:198. [PMID: 33957872 PMCID: PMC8101166 DOI: 10.1186/s12886-021-01970-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2020] [Accepted: 04/28/2021] [Indexed: 11/10/2022] Open
Abstract
Background Pseudoexfoliation (PXF) syndrome is the most common cause of secondary glaucoma worldwide. This systemic disorder causes further damage to the optic nerve and ultimately increases the need for surgical interventions. Therefore, intraocular pressure (IOP) control is very important in these patients. The aim of this study was to compare IOP changes after phacoemulsification in subjects with PXF syndrome compared to those without this syndrome. Methods 61 patients were enrolled in this prospective clinical study. Subjects were assigned into two groups based on presence or absence of PXF syndrome. IOP and anterior chamber angle parameters including: angle opening distance (AOD) and trabecular-iris surface area (TISA) measured one day preoperatively and 3 months postoperatively. Intraoperative metrics factors including: infusion fluid usage (IFU), cumulative dissipated energy (CDE) and aspiration time (AT) were obtained from the phacoemulsification machine at the end of each surgery. IOP changes, anterior chamber angle parameters and intraoperative metrics factors were compared between groups. Results Mean IOP before surgery was significantly higher in the PXF group (14.70 mm Hg) compared to controls (12.87 mm Hg) (P-value < 0.01). Phacoemulsification decreased IOP in both, but to greater extent in the PXF group (p-value < 0.01). AOD and TISA also increased significantly following surgery in both groups. The results showed that postoperative IOP was negatively correlated with preoperative IOP in both groups (p-value < 0.01). Also, IOP after phacoemulsification was negatively correlated with IFU in the PXF group (p-value = 0.03). Conclusions Patients with PXF syndrome exhibited a reduction in IOP and increase in anterior chamber angle parameters after phacoemulsification. We observed a greater IOP reduction in PXF subjects when it was compared to controls. Higher preoperative IOP and intraoperative IFU were associated with more IOP reduction in the PXF group.
Collapse
Affiliation(s)
- Farshid Ramezani
- Clinical Research Development Center, Imam Khomeini and Mohammad Kermanshahi and Farabi Hospitals, Kermanshah University of Medical Sciences, Kermanshah, Iran
| | - Mohammad Nazarian
- Clinical Research Development Center, Imam Khomeini and Mohammad Kermanshahi and Farabi Hospitals, Kermanshah University of Medical Sciences, Kermanshah, Iran
| | - Leila Rezaei
- Clinical Research Development Center, Imam Khomeini and Mohammad Kermanshahi and Farabi Hospitals, Kermanshah University of Medical Sciences, Kermanshah, Iran.
| |
Collapse
|
3
|
Wang Q, Perez CI, Masis M, Feinstein M, Mora M, Lin SC, Hsia YC. Post-phacoemulsification iris changes in eyes with glaucoma or glaucoma suspect status. PLoS One 2018; 13:e0208776. [PMID: 30543659 PMCID: PMC6292659 DOI: 10.1371/journal.pone.0208776] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2018] [Accepted: 11/21/2018] [Indexed: 12/29/2022] Open
Abstract
Purpose This prospective study used anterior segment optical coherence tomography (AS-OCT) to determine how phacoemulsification (phaco) changes iris parameters in eyes with glaucoma or glaucoma suspect status. Methods Using Visante AS-OCT (Carl Zeiss Meditec AG), the following pre- and post-phaco parameters were measured: IT750 = iris thickness at 750 μm from the scleral spur; IT2000 = iris thickness 2000 μm from the scleral spur; ITCM = the maximum iris thickness at the middle one third of the iris; ICURV = iris curvature; IAREA = iris area; and pupil size = pupil diameter (mm). Only high-quality images with an identifiable scleral spur were included, and only the nasal quadrant was analyzed. A single glaucoma specialist analyzed the parameters according to the Zhongshan Angle Assessment Program (ZAAP, Guangzhou, China). Multivariate analysis was performed using mixed effects regression correcting for age, gender, and ethnicity. Results 89 subjects and 110 eyes were included in this study. The mean age of subjects was 74.83 {+/-} 8.69 years old. Most common diagnoses were POAG and glaucoma suspect (23% and 52%, respectively), and 16% of subjects had an LPI. In multivariate analysis of AS-OCT parameters, decreases in IT750, IT2000, ITCM, ICURV, and pupil size were statistically significant (p<0.05). Conclusions After phacoemulsification, eyes with glaucoma as well as glaucoma suspect eyes have thinner irises and smaller pupils. This may lead to less iris-mediated aqueous outflow obstruction, providing support for early phacoemulsification glaucoma treatment. Translational relevance Our AS-OCT imaging findings may guide clinical practice as iris parameters become increasingly relevant in preoperative phaco planning.
Collapse
Affiliation(s)
- Qinyun Wang
- University of California at San Francisco, Department of Ophthalmology, San Francisco, California, United States of America
- * E-mail:
| | - Claudio I. Perez
- University of California at San Francisco, Department of Ophthalmology, San Francisco, California, United States of America
- Fundación Oftalmológica los Andes, Universidad los Andes, Santiago, Chile
| | - Marissé Masis
- University of California at San Francisco, Department of Ophthalmology, San Francisco, California, United States of America
| | - Max Feinstein
- University of California at San Francisco, Department of Ophthalmology, San Francisco, California, United States of America
| | - Marta Mora
- University of California at San Francisco, Department of Ophthalmology, San Francisco, California, United States of America
| | - Shan C. Lin
- University of California at San Francisco, Department of Ophthalmology, San Francisco, California, United States of America
| | - Yen C. Hsia
- University of California at San Francisco, Department of Ophthalmology, San Francisco, California, United States of America
| |
Collapse
|
4
|
Alaghband P, Beltran-Agulló L, Galvis EA, Overby DR, Lim KS. Effect of phacoemulsification on facility of outflow. Br J Ophthalmol 2018; 102:1520-1526. [PMID: 29654113 PMCID: PMC6241621 DOI: 10.1136/bjophthalmol-2017-311548] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2017] [Revised: 01/15/2018] [Accepted: 01/19/2018] [Indexed: 11/24/2022]
Abstract
Purpose Phacoemulsification has been shown to reduce intraocular pressure (IOP). The mechanism of action is thought to be via increased trabecular outflow facility. However, studies on the relationship between phacoemulsification and outflow facility have been inconsistent. This study intended to examine the change in electronic Schiotz tonographic outflow facility (TOF) and IOP measurements following phacoemulsification. Methods Patients who were due to undergo a standard clear corneal incision phacoemulsification with intraocular lens (IOL) implantation, at St Thomas’ Hospital, were invited to participate in this study. IOP was measured using Goldmann’s applanation tonometer, and TOF was measured by electronic Schiotz tonography at baseline and at 3, 6 and 12 months postoperatively. Results Forty-one patients were recruited. Tonography data for 27 patients were reliable and available at all time points. Eleven cases had primary open angle glaucoma and cataract, while 16 patients had cataract only. Mean IOP reduced at every time point postoperatively significantly compared with baseline. TOF improved significantly after cataract extraction at all time points (baseline of 0.14±0.06 vs 0.18±0.09 at 3 months, P=0.02 and 0.20±0.09 at 6 months, P=0.003, 0.17±0.07 µL/min mmHg at 12 months, P=0.04). Five contralateral eyes of patients with cataracts only who did not have any intraocular surgery during the follow-up period were used as comparison. Their IOP and TOF did not change significantly at any postoperative visits. Conclusion This is the first study using electronic Schiotz tonography with documented anterior chamber depth and gonioscopy after modern cataract surgery (CS) with phacoemulsification and IOL implantation. We demonstrated that phacoemulsification increases TOF and this fully accounts for the IOP reduction following CS. ISTCRN registration number ISRCTN04247738.
Collapse
Affiliation(s)
- Pouya Alaghband
- Ophthalmology, St Thomas' Hospital, London, UK.,Academic ophthalmology, King's College London, London, UK
| | - Laura Beltran-Agulló
- Ophthalmology, St Thomas' Hospital, London, UK.,Ophthalmology, Institut Català de la Retina, Barcelona, Spain
| | | | - Darryl R Overby
- Department of Bioengineering, Imperial College London, London, UK
| | - Kin Sheng Lim
- Ophthalmology, St Thomas' Hospital, London, UK.,Academic ophthalmology, King's College London, London, UK
| |
Collapse
|
5
|
Pelitli Gürlü V, Güçlü H, Özal A, Benian Ö, Alimgil L. Comparison of long-term results of trabeculectomy to treat pseudoexfoliative glaucoma and primary open angle glaucoma. Int J Ophthalmol 2018; 11:66-70. [PMID: 29375993 PMCID: PMC5767660 DOI: 10.18240/ijo.2018.01.12] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2017] [Accepted: 09/14/2017] [Indexed: 11/23/2022] Open
Abstract
AIM To compare the long term outcome of trabeculectomy in patients with pseudoexfoliative glaucoma (PEG) and primary open angle glaucoma (POAG) in terms of surgical success. METHODS The success of the trabeculectomy was evaluated by three criteria. Criterion A: intraocular pressure (IOP) ≤21 mm Hg and decrease in IOP ≥20%; Criterion B: IOP ≤18 mm Hg and decrease in IOP ≥30%; Criterion C: IOP ≤15 mm Hg and decrease in IOP ≥50%. Patients that met these criteria without medical treatment were considered to be completely successful, while those that met these criteria with medical treatment were considered partially successful. Significance levels of differences between the POAG and PEG groups in the Kaplan-Meier survival curves were calculated with the log-rank test. RESULTS Sixty-four eyes from 64 patients with PEG and 51 eyes from 51 patients with POAG were evaluated. No significant differences were detected between the PEG and POAG groups according to full or partial success relative to each of the three criteria (A: P=0.73, 0.32; B: P=0.73, 0.31; C:P=0.90, 0.27). CONCLUSION There is no difference in the long-term success of trabeculectomy between PEG and POAG patients whose clinical characteristics are otherwise the same.
Collapse
Affiliation(s)
- Vuslat Pelitli Gürlü
- Department of Ophthalmology, Trakya University Medical School, Edirne 22030, Turkey
| | - Hande Güçlü
- Department of Ophthalmology, Trakya University Medical School, Edirne 22030, Turkey
| | - Altan Özal
- Department of Ophthalmology, Trakya University Medical School, Edirne 22030, Turkey
| | - Ömer Benian
- Department of Ophthalmology, Ekol Private Hospital, Edirne 22030, Turkey
| | - Levent Alimgil
- Department of Ophthalmology, Medicana Private Hospital, Istanbul 34520, Turkey
| |
Collapse
|
6
|
Jimenez-Roman J, Lazcano-Gomez G, Martínez-Baez K, Turati M, Gulías-Cañizo R, Hernández-Zimbrón LF, Ochoa-De la Paz L, Zamora R, Gonzalez-Salinas R. Effect of phacoemulsification on intraocular pressure in patients with primary open angle glaucoma and pseudoexfoliation glaucoma. Int J Ophthalmol 2017; 10:1374-1378. [PMID: 28944195 DOI: 10.18240/ijo.2017.09.07] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2017] [Accepted: 04/14/2017] [Indexed: 11/23/2022] Open
Abstract
AIM To compare the effect of phacoemulsification on intraocular pressure (IOP) in patients with primary open angle glaucoma (POAG) and pseudoexfoliation glaucoma (PXG). METHODS A retrospective comparative case series conducted at the Glaucoma Department at the Association to Prevent Blindness in Mexico. The study enrolled consecutive patients having phacoemulsification with intraocular lens (IOL) implantation and a diagnosis of POAG or PXG. Data about IOP values and number of glaucoma medications used was collected at baseline, 1, 3, 6 and 12mo postoperatively. RESULTS The study enrolled 88 patients (88 eyes). After phacoemulsification, there was a statistically significant reduction in IOP values and glaucoma medications use compared to baseline in both POAG and PXG patients (P<0.001). In the POAG group, a 20% decrease in IOP values was evidenced, and a 56.5% reduction in the number of medications used at the one-year follow-up. The PXG group showed a 20.39%, and a 34.46% decrease in IOP and number of medications used, respectively. A significant difference in the mean ΔIOP (postoperative changes in IOP) was evidenced between groups (P=0.005). The reduction of the postsurgical IOP mean values in both groups, the POAG group showed a greater reduction in IOP values compared to the PXG group. CONCLUSION In both types of glaucoma, phacoemulsification cataract surgery can result in a significant IOP reduction (20%) over a 12mo follow-up period. The number of medications used is also significantly reduced up to 12mo after surgery, especially in the PXG group.
Collapse
Affiliation(s)
- Jesus Jimenez-Roman
- Glaucoma Department, Asociation to Prevent Blindness in Mexico, Mexico City 04030, Mexico
| | - Gabriel Lazcano-Gomez
- Glaucoma Department, Asociation to Prevent Blindness in Mexico, Mexico City 04030, Mexico
| | - Karina Martínez-Baez
- Glaucoma Department, Asociation to Prevent Blindness in Mexico, Mexico City 04030, Mexico
| | - Mauricio Turati
- Glaucoma Department, Asociation to Prevent Blindness in Mexico, Mexico City 04030, Mexico
| | - Rosario Gulías-Cañizo
- Research Department, Asociation to Prevent Blindness in Mexico, Mexico City 04030, Mexico.,Cell Biology Department, Advanced Research Center, I.P.N. (CINVESTAV) in Mexico City, Mexico City 07360, Mexico
| | | | - Lenin Ochoa-De la Paz
- Research Department, Asociation to Prevent Blindness in Mexico, Mexico City 04030, Mexico
| | - Rubén Zamora
- Research Department, Asociation to Prevent Blindness in Mexico, Mexico City 04030, Mexico
| | | |
Collapse
|