1
|
Qin X, Chen X, Zhao X, Yao L, Li B, Pan G, Xu J, Jiang R, Zhao Z, Liang Z, Guo X, Huang J, Li X. Evaluation of brain function in adult patent ductus arteriosus surgery: A multimodal monitoring approach. Curr Probl Cardiol 2024; 49:102334. [PMID: 38142948 DOI: 10.1016/j.cpcardiol.2023.102334] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2023] [Revised: 12/04/2023] [Accepted: 12/12/2023] [Indexed: 12/26/2023]
Abstract
Adult patent ductus arteriosus (PDA) repair surgery often involves hypothermic cardiopulmonary bypass (CPB) and is associated with postoperative neurological complications. Our study evaluates brain function during PDA surgery using regional cerebral oxygen saturation (rSO2) and bispectral index (BIS) monitoring to mitigate these complications. Patients were categorized into moderate (26-31 ℃) and mild (32-35 ℃) hypothermia groups. Findings indicate a positive correlation between PDA diameter and pulmonary artery systolic blood pressure, and a strong correlation between delirium and average rSO2-AUC. The mild hypothermia group had longer extubation and hospitalization times. During CPB, rSO2 levels fluctuated significantly, and EEG analysis revealed changes in brain wave patterns. One case of nerve injury in the mild hypothermia group showed incomplete recovery after a year. Our results advocate for moderate hypothermia during CPB in adult PDA repair, suggesting that combined rSO2 and BIS monitoring can reduce neurological complications post-surgery.
Collapse
Affiliation(s)
- Xuewei Qin
- Department of Anesthesiology, Peking University International Hospital, Beijing 102206, China
| | - Xuanling Chen
- Department of Anesthesiology, Peking University International Hospital, Beijing 102206, China
| | - Xin Zhao
- Department of Anesthesiology, Peking University International Hospital, Beijing 102206, China
| | - Lan Yao
- Department of Anesthesiology, Peking University International Hospital, Beijing 102206, China.
| | - Bin Li
- Department of Cardiac Surgery, Peking University International Hospital, Beijing 102206, China
| | - Guangyu Pan
- Department of Cardiac Surgery, Peking University International Hospital, Beijing 102206, China
| | - Jianping Xu
- Department of Cardiac Surgery, Peking University International Hospital, Beijing 102206, China; Department of Cardiac Surgery, National Center for Cardiovascular Diseases and Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - Rui Jiang
- Department of Cardiac Surgery, National Center for Cardiovascular Diseases and Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | | | | | - Xiangyang Guo
- Department of Anesthesiology, Peking University Third Hospital, Beijing 100191, China
| | - Jiapeng Huang
- Department of Anesthesiology and Perioperative Medicine, University of Louisville, Louisville, KY 40202, USA
| | - Xiaoli Li
- The State Key Laboratory of Cognitive Neuroscience and Learning & IDG/McGovern Institute for Brain Research, Beijing Normal University, Beijing 100875, China
| |
Collapse
|
2
|
Transcatheter patent ductus arteriosus closure in extremely premature infants. PROGRESS IN PEDIATRIC CARDIOLOGY 2021. [DOI: 10.1016/j.ppedcard.2021.101366] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
3
|
Diab KA, Boujemline Y, Hijazi ZM. Update on shunt closure in neonates and infants. Expert Rev Cardiovasc Ther 2021; 19:475-492. [PMID: 33899641 DOI: 10.1080/14779072.2021.1922079] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
Introduction: Cardiac defects that result in shunting are the most common types of congenital heart anomalies. Although these lesions can be simple, they can cause significant hemodynamic changes and can be challenging to manage in neonates and infants. Over the recent decades, the development of new transcatheter techniques and devices has made it safe and feasible to manage such defects when indicated, even in the smallest of patients. Understanding these interventional procedures is essential in order to manage those patients.Areas covered: In this article, we review the techniques and experience for closure of atrial septal defects, ventricular septal defects, patent ductus aarteriosus,as well as coronary arteriovenous malformations and fistulas in neonates and infants. Literature review of PubMed articles was performed through January 2021, with focus on the latest data and results of the usage of interventional techniques in treating these lesions specifically in this age-group.Expert opinion: Significant shunting lesions can be particularly challenging to manage in neonates and infants. Newer lower profile devices will likely continue to be developed in the future, allowing their use for transcatheter interventions in even smaller patients and those with more complex anatomy.
Collapse
Affiliation(s)
- Karim A Diab
- Department of Pediatrics, Sidra Heart Center, Sidra Medicine, Doha, Qatar
| | - Younes Boujemline
- Department of Pediatrics, Sidra Heart Center, Sidra Medicine, Doha, Qatar
| | - Ziyad M Hijazi
- Department of Pediatrics, Sidra Heart Center, Sidra Medicine, Doha, Qatar.,Weill Cornell Medical College, Doha, Qatar.,Weill Cornell Medical College, New York, NY, USA
| |
Collapse
|
4
|
Percutaneous Closure of Patent Ductus Arteriosus in Infants 1.5 kg or Less: A Meta-Analysis. J Pediatr 2021; 230:84-92.e14. [PMID: 33098843 DOI: 10.1016/j.jpeds.2020.10.035] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/25/2020] [Revised: 10/15/2020] [Accepted: 10/16/2020] [Indexed: 11/22/2022]
Abstract
OBJECTIVE To investigate technical success and safety of percutaneous patent ductus arteriosus closure in infants ≤1.5 kg. STUDY DESIGN A systematic review and meta-analysis was performed. Data sources included Scopus, Web of Science, Embase, CINAHL, Cochrane, and PubMed from inception to April 2020. Publications were included if they had a clear definition of the intervention as percutaneous patent ductus arteriosus closure in infants ≤1.5 kg. Data extraction was independently performed by multiple observers. Primary outcome was technical success and secondary outcomes were adverse events (AEs). Subgroup analysis was performed in infants ≤6.0 kg. Data were pooled by using a random-effects model. RESULTS We included 28 studies, including 373 infants ≤1.5 kg and 69 studies enrolling 1794 infants ≤6.0 kg. In patients ≤1.5 kg, technical success was 96% (95% CI, 93%-98%; P = .16; I2 = 23%). The overall incidence of AE was 27% (95% CI, 17%-38%; P < .001; I2 = 70%) and major AEs was 8% (95% CI, 5%-10%; P = .63; I2 = 0%). There were 5 deaths related to the procedure (2%; 95% CI, 1%-4%; P = .99; I2 = 0%); 4 of these deaths occurred in infants <0.8 kg. The probability of technical failure was inversely related to age at the time of the procedure (OR, 0.9; 95% CI, 0.830-0.974; P = .009). Weight at intervention has decreased over time and procedural success has increased. CONCLUSIONS Percutaneous patent ductus arteriosus closure is feasible in infants ≤1.5 kg with few major AEs. The procedural success rate is high, despite performing the intervention in smaller patients. PROSPERO REGISTRATION CRD42020145230.
Collapse
|
5
|
Uppal L, Rohit MK, Barwad P, Naganur S, Debi U, Kasinadhuni G, Santosh K, Cr P, Sahoo S. Comparison of isolated venous approach with the standard approach in children undergoing patent ductus arteriosus device closure. Egypt Heart J 2020; 72:65. [PMID: 32990909 PMCID: PMC7524916 DOI: 10.1186/s43044-020-00100-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2020] [Accepted: 09/21/2020] [Indexed: 12/18/2022] Open
Abstract
BACKGROUND Transcatheter device closure is a safe procedure recommended in children with patent ductus arteriosus (PDA). While the standard procedure uses arterial and venous femoral access, it poses risk of vascular complications especially in young infants. Isolated venous approach has been tried in a few studies and was found to be non-inferior to the standard technique. In this prospective observational study, we have compared the two vascular approaches of PDA device closure in pediatric patients and have also studied the feasibility of this approach in young children with weight < 6 kg. RESULTS PDA device occlusion was performed with either one of the approaches-venous alone (group I) or standard approach (group II) in a total of 135 children enrolled prospectively. The baseline data, procedural outcomes, vascular complications, and radiation dose were compared between the two groups. Fifty-two and 83 children were included in group I and group II, respectively. A total of 22 children (16%) (13 in group I; 9 in group II) had weight < 6 kg. In group II, 6 children (7.2%) had vascular site complications treated with heparin infusion with two children requiring thrombolysis. Another child in group II developed intravascular hemolysis following residual shunt, requiring surgical device retrieval and closure. No significant differences were observed in mean fluoroscopic time (p = 0.472) and air kerma between the two groups (p = 0.989). CONCLUSION Transcatheter PDA device closure without arterial access is a feasible and safe option in children including young infants. This technique avoids the risk of vascular complications although requires careful case selection.
Collapse
Affiliation(s)
- Lipi Uppal
- Department of Cardiology, Post Graduate Institute of Medical Education and Research, Chandigarh, 160012, India
| | - Manoj Kumar Rohit
- Department of Cardiology, Post Graduate Institute of Medical Education and Research, Chandigarh, 160012, India.
| | - Parag Barwad
- Department of Cardiology, Post Graduate Institute of Medical Education and Research, Chandigarh, 160012, India
| | - Sanjeev Naganur
- Department of Cardiology, Post Graduate Institute of Medical Education and Research, Chandigarh, 160012, India
| | - Uma Debi
- Department of Radiodiagnosis, Post Graduate Institute of Medical Education and Research, Chandigarh, 160012, India
| | - Ganesh Kasinadhuni
- Department of Cardiology, Post Graduate Institute of Medical Education and Research, Chandigarh, 160012, India
| | - Krishna Santosh
- Department of Cardiology, Post Graduate Institute of Medical Education and Research, Chandigarh, 160012, India
| | - Pruthvi Cr
- Department of Cardiology, Post Graduate Institute of Medical Education and Research, Chandigarh, 160012, India
| | - Saroj Sahoo
- Department of Cardiology, Post Graduate Institute of Medical Education and Research, Chandigarh, 160012, India
| |
Collapse
|
6
|
Kanabar K, Bootla D, Kaur N, Pruthvi CR, Krishnappa D, Santosh K, Guleria V, Rohit MK. Outcomes of transcatheter closure of patent ductus arteriosus with the off-label use of large occluders (≥16 mm). Indian Heart J 2020; 72:107-112. [PMID: 32534682 PMCID: PMC7296248 DOI: 10.1016/j.ihj.2020.03.009] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2019] [Revised: 10/23/2019] [Accepted: 03/28/2020] [Indexed: 01/19/2023] Open
Abstract
OBJECTIVE Transcatheter closure is the first-choice strategy for the management of appropriate patients with patent ductus arteriosus (PDA). The management of large PDAs is challenging due to the limited available sizes of approved devices and the inherent risks of surgical ligation, especially in adults with calcified PDAs. This study aimed to assess the outcomes of the off-label use of large occluders at a tertiary center. METHODS This retrospective review included patients who underwent transcatheter PDA closure with large occluders (≥16 mm) over 16 years. The baseline patient data, procedural details, angiograms, and immediate outcomes were recorded and patients were followed up at 3, 6, 12 months after the intervention and annually thereafter. RESULTS Of the 685 patients who underwent transcatheter PDA closure, 36 patients (mean age 16.6 ± 12.5 years) needed occluders ≥ 16 mm in size. Cocoon duct occluder, Cera duct occluder, Amplatzer atrial septal occluder (ASO), and Cera muscular ventricular septal defect occluders were used for PDA closure. There was no device embolization, one patient in whom ASO was used had residual shunt with intravascular hemolysis requiring surgery, and one patient had mild left pulmonary artery narrowing after the intervention, which was managed conservatively. No patient had residual shunt and one patient had persistent pulmonary hypertension at an intermediate duration of follow-up. CONCLUSION Transcatheter PDA closure with the use of large devices, which are available in Asia and Europe, is an effective and safe method, especially in adolescents and adults. However, a close follow-up of these patients is mandatory.
Collapse
Affiliation(s)
- Kewal Kanabar
- Department of Cardiology, Postgraduate Institute of Medical Education and Research, Chandigarh, 160012, India
| | - Dinakar Bootla
- Department of Cardiology, Postgraduate Institute of Medical Education and Research, Chandigarh, 160012, India
| | - Navjyot Kaur
- Department of Cardiology, Postgraduate Institute of Medical Education and Research, Chandigarh, 160012, India
| | - C R Pruthvi
- Department of Cardiology, Postgraduate Institute of Medical Education and Research, Chandigarh, 160012, India
| | - Darshan Krishnappa
- Department of Cardiology, Postgraduate Institute of Medical Education and Research, Chandigarh, 160012, India
| | - Krishna Santosh
- Department of Cardiology, Postgraduate Institute of Medical Education and Research, Chandigarh, 160012, India
| | - Vivek Guleria
- Department of Cardiology, Postgraduate Institute of Medical Education and Research, Chandigarh, 160012, India
| | - Manoj Kumar Rohit
- Department of Cardiology, Postgraduate Institute of Medical Education and Research, Chandigarh, 160012, India.
| |
Collapse
|
7
|
Ye Z, Li Z, Yi H, Zhu Y, Sun Y, Li P, Ma N. Percutaneous device closure of pediatirc patent ductus arteriosus through femoral artery guidance by transthoracic echocardiography without radiation and contrast agents. J Cardiothorac Surg 2020; 15:107. [PMID: 32448306 PMCID: PMC7245820 DOI: 10.1186/s13019-020-01119-w] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2020] [Accepted: 04/27/2020] [Indexed: 11/20/2022] Open
Abstract
Background For many years, percutaneous interventional occlusion of congenital patent ductus arteriosus (PDA) has been completed using radiation and contrast agents. In this study, transthoracic echocardiography without radiation and contrast agents was used to complete percutaneous occlusion of pediatric PDA. Methods Thirty-two children (8 males and 24 females) with normal heart function and no other intracardiac deformities were diagnosed with PDA (20 funnel type; 12 tube type), One patient had peripheral facial paralysis, 1 patient had epilepsy, and 1 case had multiple cervical deformities. All procedures were performed in the surgical operating room (without Digital Subtraction Angiography (DSA) equipment) under basic anesthesia through the femoral artery pathway. The procedures were guided by transthoracic echocardiography (TTE) by establishing an orbit with a catheter through the femoral artery to thepatent ductus arteriosus,pulmonary artery and right ventricle. A suitable ventricular septal defect occluder was placed using the femoral artery approach,and the treatment effect was evaluated by echocardiography after occlusion. The Outpatient follow-up was performed at 1, 3 months after the operation. Results All cases had successful closure of PDA, which took only 35.6 ± 6.4 min. The diameter of the device was 4.8 ± 2.3 mm, and the heart murmur disappeared. There was no shunt between the left pulmonary artery and the descending aortic artery, and the length of hospitalization was 3.4 ± 0.5 days. No other incisions were needed in 32 cases. No occluder was removed, and no residual shunt was found after operation; moreover, no ICU stay was needed, and the mean hospital stay was 3.4 ± 0.5 days. No residual shunt was found at the 1-, 3-month follow-up visit. Conclusions PDA closure guided by transthoracic echocardiography via femoral artery puncture is a minimally invasive procedure that avoids injuries due to radiation and contrast agents. This method has wider application prospects in pediatrics.
Collapse
Affiliation(s)
- Zankai Ye
- Department of Cardiac Surgery, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, 100045, China
| | - Zhiqiang Li
- Department of Cardiac Surgery, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, 100045, China.
| | - Hanlu Yi
- Department of Cardiac Surgery, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, 100045, China
| | - Yaobin Zhu
- Department of Cardiac Surgery, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, 100045, China
| | - Yan Sun
- Department of Echocardiography, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, 100045, China
| | - Pei Li
- Department of Echocardiography, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, 100045, China
| | - Ning Ma
- Department of Echocardiography, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, 100045, China.
| |
Collapse
|
8
|
Shah J, Bhalodiya D, Pravinchandra A, Saraiya S. Safety and efficacy of transcatheter device closure of patent ductus arteriosus in pediatric patients: Long-term outcomes. HEART INDIA 2020. [DOI: 10.4103/heartindia.heartindia_6_20] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|
9
|
Gu Q, Ma L, Gu H, Meng Y, Shen C, Kong X, Shao Y, Zhang S. A hybrid approach for patent ductus arteriosus closure using the Amplatzer Duct Occluder. J Card Surg 2018; 33:684-687. [PMID: 30221386 DOI: 10.1111/jocs.13817] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
OBJECTIVE We performed closure of the patent ductus arteriosus (PDA) using a hybrid approach with an Amplatzer Duct Occluder. METHODS Six patients (two males and four females) underwent PDA closure at a mean age of 7.8 months (range 2-24 months) and a mean weight of 6.6 kg (range 4.5-13 kg). The main pulmonary artery (MPA) was exposed via a minimally invasive left parasternal second intercostal space incision. Under transesophageal echocardiography guidance, the PDA occluder was implanted via direct puncture of the MPA. RESULTS The procedure was successful in all patients with no residual shunt. There were no hospital deaths, and the postoperative course was uneventful. All patients were discharged on the 3rd to 4th day. There was no residual shunt in any patient on midterm follow-up. CONCLUSIONS The novel hybrid approach is a safe, minimal invasive procedure. Further experience and longer follow-up of these patients is necessary to conclude whether this technique is applicable to all the patients with a PDA.
Collapse
Affiliation(s)
- Qun Gu
- Department of Cardiovascular Surgery, The First Affiliated Hospital with Nanjing Medical University, Nanjing, Jiangsu Province, China
| | - Luyao Ma
- Department of Cardiovascular Surgery, The First Affiliated Hospital with Nanjing Medical University, Nanjing, Jiangsu Province, China
| | - Haitao Gu
- Department of Cardiovascular Surgery, The First Affiliated Hospital with Nanjing Medical University, Nanjing, Jiangsu Province, China
| | - Yaling Meng
- Department of Cardiovascular Surgery, The First Affiliated Hospital with Nanjing Medical University, Nanjing, Jiangsu Province, China
| | - Chen Shen
- Department of Cardiovascular Surgery, The First Affiliated Hospital with Nanjing Medical University, Nanjing, Jiangsu Province, China
| | - Xiangyin Kong
- Department of Cardiovascular Surgery, The First Affiliated Hospital with Nanjing Medical University, Nanjing, Jiangsu Province, China
| | - Yongfeng Shao
- Department of Cardiovascular Surgery, The First Affiliated Hospital with Nanjing Medical University, Nanjing, Jiangsu Province, China
| | - Shijiang Zhang
- Department of Cardiovascular Surgery, The First Affiliated Hospital with Nanjing Medical University, Nanjing, Jiangsu Province, China
| |
Collapse
|
10
|
Udink ten Cate FE, Sobhy R, Kalantre A, Sachdev S, Subramanian A, Koneti NR, Kumar RK, Hamza H, Jayranganath M, Sreeram N. Off-label use of duct occluder devices to close hemodynamically significant perimembranous ventricular septal defects: A multicenter experience. Catheter Cardiovasc Interv 2018; 93:82-88. [DOI: 10.1002/ccd.27792] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/24/2018] [Revised: 06/15/2018] [Accepted: 06/20/2018] [Indexed: 11/05/2022]
Affiliation(s)
- Floris E.A. Udink ten Cate
- Department of Pediatric Cardiology; Heart Center Cologne, University Hospital of Cologne; Cologne Germany
- Department of Pediatric Cardiology; Amalia Children's Hospital, Radboud University Medical Center; Nijmegen The Netherlands
| | - Rodina Sobhy
- Department of Pediatric Cardiology; Cairo University Children's Hospital; Cairo Egypt
| | - Atul Kalantre
- Department of Pediatric Cardiology; Amrita Institute of Medical Sciences; Kochi India
| | - Sakshi Sachdev
- Department of Pediatric Cardiology; CARE Hospital; Hyderabad India
| | - Anand Subramanian
- Sri Jayadeva Institute of Cardiovascular Sciences and Research; Bengaluru India
| | | | - Raman Krishna Kumar
- Department of Pediatric Cardiology; Amrita Institute of Medical Sciences; Kochi India
| | - Hala Hamza
- Department of Pediatric Cardiology; Cairo University Children's Hospital; Cairo Egypt
| | | | - Narayanswami Sreeram
- Department of Pediatric Cardiology; Heart Center Cologne, University Hospital of Cologne; Cologne Germany
| |
Collapse
|
11
|
Anna Venugopalan VB, Wilson N, Archer N, Adwani S. Clinical Outcome at One Year of Age Following Device Closure of Patent Ductus Arteriosus (PDA) in Small Babies. Indian J Pediatr 2018; 85:584. [PMID: 29417457 DOI: 10.1007/s12098-018-2634-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/14/2017] [Accepted: 01/23/2018] [Indexed: 11/29/2022]
Affiliation(s)
- Vikranth Bapu Anna Venugopalan
- Department of Neonatology, Birmingham City Hospital, Sandwell & West Birmingham Hospitals NHS Trust, Dudley Road, Birmingham, B18 7QH, UK.
| | - Neil Wilson
- Department of Pediatric Cardiology, John Radcliffe Hospital, Oxford, UK
| | - Nick Archer
- Department of Pediatric Cardiology, John Radcliffe Hospital, Oxford, UK
| | - Satish Adwani
- Department of Pediatric Cardiology, John Radcliffe Hospital, Oxford, UK
| |
Collapse
|
12
|
Transcatheter Closure of Arterial Duct in Infants < 6 kg: Amplatzer Duct Occluder Type I vs Amplatzer Duct Occluder II Additional Sizes. Pediatr Cardiol 2018; 39:627-632. [PMID: 29453685 DOI: 10.1007/s00246-018-1828-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/29/2017] [Accepted: 02/01/2018] [Indexed: 10/18/2022]
Abstract
Transcatheter closure of arterial duct (AD) remains challenging in low-weight patients and using Amplatzer Duct Occluder devices is still considered off-label in infants < 6 kg. This study aimed to report a large, single-center experience of percutaneous AD closure in infants < 6 kg as well as to compare the most frequently used devices, Amplatzer Duct Occluder type I (ADO I) and Amplatzer Duct Occluder type II Additional Sizes devices (ADO II-AS) (St. Jude Medical Corp, St. Paul, MN, USA). From March 2000 to March 2017, among the 762 patients submitted to percutaneous closure of AD at our Institution, 33 were infants < 6 kg (age 4.8 ± 2.1 months; weight 5.0 ± 0.9 kg). Fourteen patients (45%) underwent ADO I (Group I) and 19 patients ADO II-AS (Group II) device implantation. AD diameter was 2.6 ± 0.8 (range 1.5-4.0) mm resulting in QP/QS of 2.6 ± 0.0.9 (range 1.1-4.5). Successful device deployment was achieved in all patients without procedural morbidity or mortality. Procedural and fluoroscopy times were not significantly different between the groups. However, total X-ray absorbed dose was significantly higher in Group I (121 ± 69 vs 29 ± 16 mGy/cm2, p < 0.01). Immediate, 24 h, and mid-term (46 ± 37 months, median 39) complete occlusion were recorded in 72.7, 90.9, and 97% of patients, respectively without significant difference between the groups. In conclusion, transcatheter closure of AD with Amplatzer Duct Occluder devices is feasible, safe, and effective also in infants less than 6 kg, without significant difference between the most commonly used devices, namely, ADO I and ADO II-AS.
Collapse
|
13
|
Roushdy A, Abd el razek Y, Mamdouh Tawfik A. Echocardiographic predictors of coil vs device closure in patients undergoing percutaneous patent ductus arteriosus closure. Echocardiography 2018; 35:71-78. [DOI: 10.1111/echo.13748] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/01/2023] Open
Affiliation(s)
- Alaa Roushdy
- Cardiology Department; Ain Shams University Hospital; Cairo Egypt
| | | | | |
Collapse
|
14
|
Shafi NA, Singh GD, Smith TW, Rogers JH. Sizing of patent ductus arteriosus in adults for transcatheter closure using the balloon pull-through technique. Catheter Cardiovasc Interv 2017; 91:1159-1163. [DOI: 10.1002/ccd.27303] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/06/2017] [Revised: 06/14/2017] [Accepted: 08/04/2017] [Indexed: 11/10/2022]
Affiliation(s)
- Nabil A. Shafi
- Division of Cardiovascular Medicine; University of California, Davis Medical Center; Sacramento California
| | - Gagan D. Singh
- Division of Cardiovascular Medicine; University of California, Davis Medical Center; Sacramento California
| | - Thomas W. Smith
- Division of Cardiovascular Medicine; University of California, Davis Medical Center; Sacramento California
| | - Jason H. Rogers
- Division of Cardiovascular Medicine; University of California, Davis Medical Center; Sacramento California
| |
Collapse
|
15
|
Backes CH, Rivera BK, Bridge JA, Armstrong AK, Boe BA, Berman DP, Fick T, Holzer RJ, Hijazi ZM, Abadir S, Justino H, Bergersen L, Smith CV, Kirpalani H. Percutaneous Patent Ductus Arteriosus (PDA) Closure During Infancy: A Meta-analysis. Pediatrics 2017; 139:peds.2016-2927. [PMID: 28087683 DOI: 10.1542/peds.2016-2927] [Citation(s) in RCA: 57] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 10/31/2016] [Indexed: 11/24/2022] Open
Abstract
CONTEXT Patent ductus arteriosus (PDA) is a precursor to morbidity and mortality. Percutaneous (catheter-based) closure is the procedure of choice for adults and older children with a PDA, but use during infancy (<1 year) is not well characterized. OBJECTIVE Investigate the technical success and safety of percutaneous PDA closure during infancy. DATA SOURCES Scopus, Web of Science, Embase, PubMed, and Ovid (Medline) were searched through December 2015 with no language restrictions. STUDY SELECTION Publications needed to clearly define the intervention as percutaneous PDA closure during infancy (<1 year of age at intervention) and must have reported adverse events (AEs). DATA EXTRACTION The study was performed according to the Systematic Reviews and Meta-Analysis checklist and registered prospectively. The quality of the selected studies was critically examined. Data extraction and assignment of AE attributability and severity were independently performed by multiple observers. Outcomes were agreed on a priori. Data were pooled by using a random-effects model. RESULTS Thirty-eight studies were included; no randomized controlled trials were found. Technical success of percutaneous PDA closure was 92.2% (95% confidence interval [CI] 88.8-95.0). Overall AE and clinically significant AE incidence was 23.3% (95% CI 16.5-30.8) and 10.1% (95% CI 7.8-12.5), respectively. Significant heterogeneity and publication bias were observed. LIMITATIONS Limitations include lack of comparative studies, lack of standardized AE reporting strategy, and significant heterogeneity in reporting. CONCLUSIONS Percutaneous PDA closure during infancy is feasible and associated with few catastrophic AEs; however, the limitations constrain the interpretability and generalizability of the current findings.
Collapse
Affiliation(s)
- Carl H Backes
- Centers for Perinatal Research, .,Cardiovascular and Pulmonary Research, and.,The Heart Center, The Research Institute at Nationwide Children's Hospital, Nationwide Children's Hospital, Columbus, Ohio.,Department of Pediatrics, The Ohio State University, Columbus, Ohio
| | | | - Jeffrey A Bridge
- Department of Pediatrics, The Ohio State University, Columbus, Ohio.,Innovation in Pediatric Practice, and
| | - Aimee K Armstrong
- Cardiovascular and Pulmonary Research, and.,The Heart Center, The Research Institute at Nationwide Children's Hospital, Nationwide Children's Hospital, Columbus, Ohio.,Department of Pediatrics, The Ohio State University, Columbus, Ohio
| | - Brian A Boe
- Cardiovascular and Pulmonary Research, and.,The Heart Center, The Research Institute at Nationwide Children's Hospital, Nationwide Children's Hospital, Columbus, Ohio.,Department of Pediatrics, The Ohio State University, Columbus, Ohio
| | - Darren P Berman
- Cardiovascular and Pulmonary Research, and.,The Heart Center, The Research Institute at Nationwide Children's Hospital, Nationwide Children's Hospital, Columbus, Ohio.,Department of Pediatrics, The Ohio State University, Columbus, Ohio
| | - Tyler Fick
- Department of Pediatrics, The Ohio State University, Columbus, Ohio
| | - Ralf J Holzer
- Department of Pediatrics, Weill Cornell Medical College, New York, New York.,Cardiac Catheterization and Interventional Therapy, Sidra Cardiac Program, Sidra Medical and Research Center, Doha, Qatar
| | - Ziyad M Hijazi
- Department of Pediatrics, Weill Cornell Medical College, New York, New York.,Cardiac Catheterization and Interventional Therapy, Sidra Cardiac Program, Sidra Medical and Research Center, Doha, Qatar
| | - Sylvia Abadir
- Department of Pediatric Cardiology, CHU mère-enfant Sainte-Justine, Université de Montréal, Quebec, Canada
| | - Henri Justino
- Section of Pediatric Cardiology, Texas Children's Hospital, Baylor College of Medicine, Houston, Texas
| | - Lisa Bergersen
- Department of Cardiology, Boston Children's Hospital, Boston, Massachusetts
| | - Charles V Smith
- Center for Developmental Therapeutics, Seattle Children's Research Institute, University of Washington School of Medicine, Seattle, Washington; and
| | - Haresh Kirpalani
- Division of Neonatology, Children's Hospital of Philadelphia, Philadelphia, Pennsylvania
| |
Collapse
|
16
|
Hassine M, Hamdi S, Mlayeh D, Jomaa W, Ben Hamda K, Gamra H, Maatouk F. [Percutaneous closure of persistent ductus arteriosus in low-weight infants]. Arch Pediatr 2016; 24:112-117. [PMID: 27993443 DOI: 10.1016/j.arcped.2016.11.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2016] [Revised: 11/07/2016] [Accepted: 11/22/2016] [Indexed: 11/27/2022]
Abstract
INTRODUCTION The persistent ductus arteriosus remains a common congenital pathology. Although percutaneous closure of wide channels using an Amplatzer Duct Occluder is an attractive alternative to the surgical treatment, this prosthesis is not recommended for infants weighing less than 6kg. AIM OF THE STUDY The objective was to evaluate the efficacy and safety of this prosthesis in low-weight children. PATIENTS AND METHODS The records of children weighing less than 6kg who underwent closure with the Amplatzer Duct Occluder prosthesis between January 2010 and December 2014 were retrospectively analyzed. RESULTS Fourteen patients (mean weight: 5.7kg [range: 4.8-6]; mean age: 6.5months [range: 3-12]) were included. The main circumstance for discovery was difficulty in breathing (93% of children). The average angiographic persistent ductus arteriosus diameter was 3.5mm (range: 3-6mm), correlating well with that found on ultrasound (r=0.68). The prosthesis was implanted successfully in 93% of cases. The only failure was explained by the increased risk of aortic subocclusion. The immediate angiographic occlusion rate was 71%. The average duration of the procedure was 46±12min. Three children had a channel C-type on the Krichenko classification. Two complications occurred in two patients: a case of cardiac tamponade drained during the procedure without incident and one case of partial protrusion of the Amplatzer disk into the aortic lumen. C-type (tubular) persistent ductus arteriosus and a ratio of the diameter of the persistent ductus arteriosus/weight greater than 0.95 were significantly associated with intervention failure and/or major complications during the percutaneous closure, while weight of less than 6kg was not retained as a predictor of procedure failure. No late embolization occurred after 11months of median follow-up. During this monitoring, we noted a marked clinical improvement with normalization of pulmonary pressure. CONCLUSION This study includes the few records reported in the literature assessing the feasibility of percutaneous closure in persistent ductus arteriosus in infants weighing up to 6kg. It confirms the effectiveness of the procedure with a relatively low prevalence of complications.
Collapse
Affiliation(s)
- M Hassine
- Cardiology A department, university of Monastir, Fattouma Bourguiba university hospital, 5000 Monastir, Tunisie.
| | - S Hamdi
- Cardiology B department, university of Monastir, Fattouma Bourguiba university hospital, 5000 Monastir, Tunisie
| | - D Mlayeh
- Cardiology A department, university of Monastir, Fattouma Bourguiba university hospital, 5000 Monastir, Tunisie
| | - W Jomaa
- Cardiology B department, university of Monastir, Fattouma Bourguiba university hospital, 5000 Monastir, Tunisie
| | - K Ben Hamda
- Cardiology B department, university of Monastir, Fattouma Bourguiba university hospital, 5000 Monastir, Tunisie
| | - H Gamra
- Cardiology A department, university of Monastir, Fattouma Bourguiba university hospital, 5000 Monastir, Tunisie
| | - F Maatouk
- Cardiology B department, university of Monastir, Fattouma Bourguiba university hospital, 5000 Monastir, Tunisie
| |
Collapse
|
17
|
Ali S, El Sisi A. Transcatheter closure of patent ductus arteriosus in children weighing 10 kg or less: Initial experience at Sohag University Hospital. J Saudi Heart Assoc 2016; 28:95-100. [PMID: 27053899 PMCID: PMC4803776 DOI: 10.1016/j.jsha.2015.06.007] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2015] [Revised: 05/15/2015] [Accepted: 06/17/2015] [Indexed: 11/05/2022] Open
Abstract
Aim To assess the challenges, feasibility, and efficacy of device closure of patent ductus arteriosus (PDA) in small children weighing ⩽10 kg for different types of devices used in an initial experience at Sohag University hospital. Methods Between March 2011 and September 2014, 91 patients with PDA underwent transcatheter closure in our institute, among whom 54 weighed ⩽10 kg. All of these patients underwent transcatheter closure of PDA using either a Cook Detachable Coil, PFM Nit-Occlud, or Amplatzer duct occluder. A retrospective review of the treatment results and adverse events was performed. Results Successful device placement was achieved in 53/54 small children (98.1%). The median minimum PDA diameter was 2.4 mm [interquartile range (IQR, 1.8–3.5 mm), median weight 8 kg (IQR, 7–10 kg), and median age 10 months (IQR, 8–17 months)]. Mild aortic obstruction occurred in one case (1.9%), as the device became displaced towards the aorta after release. The device embolized in one case (1.9%) and no retrieval attempt was made. Five cases (9.3%) had minor vascular complications. Conclusion With the current availability of devices for PDA closure, transcatheter closure of PDA is considered safe and efficacious in small children weighing ⩽10 kg with good mid-term outcome. The procedure had a low rate of high-severity adverse events even with the initial experience of the catheterization laboratory.
Collapse
Affiliation(s)
- Safaa Ali
- Pediatric Department, Faculty of Medicine, Sohag University, Sohag, Egypt
| | - Amel El Sisi
- Pediatric Department, Faculty of Medicine, Sohag University, Sohag, Egypt
| |
Collapse
|
18
|
Butera G, Lovin N, Basile DP. Patent ductus arteriosus balloon sizing: A new technique to evaluate the size in complex cases. Catheter Cardiovasc Interv 2015; 87:1135-1137. [PMID: 26602995 DOI: 10.1002/ccd.26331] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/21/2015] [Accepted: 10/24/2015] [Indexed: 11/11/2022]
Abstract
Patent ductus arteriosus (PDA) transcatheter closure is a widespread procedure. However in some cases PDA measurements may be unclear and choice of the proper device could be quite difficult. This may happen in large PDA and in particular in adults. We have developed a new technique using an ASD sizing balloon to measure the PDA in order to better understand PDA anatomy and size. The first step is to create an artero-venous circuit across the PDA. A 24 or a 34 mm Amplatzer balloon sizing for ASD closure is placed over the wire from the venous access in the descending aorta. Then, the balloon is inflated and gently pulled back across the PDA toward the pulmonary artery. The frame where the balloon is exactly across the PDA is chosen and measurements performed. In conclusion, a new method for PDA measurement in large PDA is reported. The procedure is safe and reliable. © 2015 Wiley Periodicals, Inc.
Collapse
Affiliation(s)
- Gianfranco Butera
- Department of Congenital Cardiology and Cardiac Surgery, Policlinico San Donato IRCCS, Milan, 20097, Italy
| | - Nicusor Lovin
- Institutul De Boli Cardiovasculare "Prof.Dr.George I.M. Georgescu", Iasi, Romania
| | - Domenica Paola Basile
- Department of Congenital Cardiology and Cardiac Surgery, Policlinico San Donato IRCCS, Milan, 20097, Italy
| |
Collapse
|
19
|
Thanopoulos BV. Do we need a femoral artery route for transvenous PDA closure in children with ADO I? Anatol J Cardiol 2015; 15:248. [PMID: 25880177 PMCID: PMC5337063 DOI: 10.5152/akd.2015.14638] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
|
20
|
Parra-Bravo JR, Apolonio-Martínez A, Estrada-Loza MDJ, Beirana-Palencia LG, Ramírez-Portillo CI. [Lung perfusion studies after percutaneous closure of patent ductus arteriosus using the Amplatzer Duct Occluder in children]. ARCHIVOS DE CARDIOLOGIA DE MEXICO 2015; 85:188-94. [PMID: 25700578 DOI: 10.1016/j.acmx.2014.12.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2014] [Revised: 12/06/2014] [Accepted: 12/10/2014] [Indexed: 10/24/2022] Open
Abstract
OBJECTIVE The closure of patent ductus arteriosus with multiple devices has been associated with a reduction in lung perfusion. We evaluated the pulmonary perfusion after percutaneous closure of patent ductus arteriosus with the Amplatzer Duct Occluder device using perfusion lung scan. METHODS Thirty patients underwent successful percutaneous patent ductus arteriosus occlusions using the Amplatzer Duct Occluder device were included in this study. Lung perfusion scans were preformed 6 months after the procedure. Peak flow velocities and protrusion of the device were analyzed by Doppler echocardiography. A left lung perfusion<40% was considered abnormal. RESULTS The device implantation was successful in all patients. Average perfusion of left lung was 44.7±4.9% (37.8-61.4). Five patients (16.6%) showed decreased perfusion of the left lung. Age, low weight, the length of the ductus arteriosus and the minimum and maximum diameter/length of the ductus arteriosus ratio were statistically significant in patients with abnormalities of lung perfusion. It was observed protrusion the device in 6 patients with a higher maximum flow rate in the left pulmonary artery. CONCLUSION The left lung perfusion may be compromised after percutaneous closure of patent ductus arteriosus with the Amplatzer Duct Occluder. The increased flow velocity in the origin of the left pulmonary artery can be a poor indicator of reduction in pulmonary perfusion and can occur in the absence of protrusion of the device.
Collapse
Affiliation(s)
- José Rafael Parra-Bravo
- Servicio de Cardiología y Hemodinamia, Hospital de Pediatría Centro Médico Nacional Siglo XXI Instituto Mexicano del Seguro Social, México, Distrito Federal, México.
| | - Adriana Apolonio-Martínez
- Servicio de Pediatría, Hospital de Pediatría Centro Médico Nacional Siglo XXI Instituto Mexicano del Seguro Social, México, Distrito Federal, México
| | - María de Jesús Estrada-Loza
- Servicio de Cardiología y Hemodinamia, Hospital de Pediatría Centro Médico Nacional Siglo XXI Instituto Mexicano del Seguro Social, México, Distrito Federal, México
| | - Luisa Gracia Beirana-Palencia
- Servicio de Cardiología y Hemodinamia, Hospital de Pediatría Centro Médico Nacional Siglo XXI Instituto Mexicano del Seguro Social, México, Distrito Federal, México
| | - César Iván Ramírez-Portillo
- Servicio de Cardiología y Hemodinamia, Hospital de Pediatría Centro Médico Nacional Siglo XXI Instituto Mexicano del Seguro Social, México, Distrito Federal, México
| |
Collapse
|
21
|
Chen W, Yan X, Huang Y, Sun X, Zhong L, Li J, Chen H, Zhong H, Chen L. Transthoracic echocardiography as an alternative major guidance to angiography during transcatheter closure of patent ductus arteriosus: technical feasibility and clinical relevance. Pediatr Cardiol 2015; 36:14-9. [PMID: 25070385 DOI: 10.1007/s00246-014-0956-9] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/22/2013] [Accepted: 06/17/2014] [Indexed: 12/26/2022]
Abstract
The conventional transcatheter closure of patent ductus arteriosus (PDA) requires femoral artery puncture and angiography for duct anatomic and shunting estimation. If such estimation can be replaced by transthoracic echocardiography (TTE), the procedure will be further simplified, with fewer invasions. This study aimed to examine whether TTE can serve as an alternative to aorta angiography and as a major guidance for transcatheter duct closure. The study enrolled 298 consecutive patients (71 males and 227 females) with PDA. In the study, TTE with combined two-dimensional echocardiography (2DE) imaging and color-coded flow imaging (CDFI) was performed to measure the minimal shunting width (MSW) as the estimated minimal duct size for selection of an Amplatzer duct occluder (ADO) and to monitor the transcatheter duct closure intraprocedurally. The MSW was validated against the duct-stretched diameter (SDD), against the minimal waist diameter of the conical part of a released occluder measured by X-ray spot picture after successful duct closure (SDC), and against the size of the finally used ADO (SADO). Good correlation was found between MSW and SDD [SDD (mm) = 1.31 MSW; r = 0.89; p < 0.01] and between MSW and SADO [SADO (mm) = 1.71 MSW; r = 0.88; p < 0.01]. Of 296 patients who received occlusion using MSW as the reference for selection of the occluder, SDC was attained in 288 (97.3%), 5 (1.7%), and 2 (0.7%) patients, respectively, at the first, second (1 ADO replacement), and third (2 ADO replacements) occluding attempt. Acute occluder dislodgement occurred in one patient (0.3%). At the 12-month follow-up assessment, no major complications were found, and the total immediate or 12-month SDC was 99.7%. Echocardiography as an alternative major guidance to angiography for transcatheter duct closure is technically feasible, and TTE guidance can further simplify the procedure, with fewer invasions and potential complications.
Collapse
Affiliation(s)
- Wanhua Chen
- Department of Cardiology, The Affiliated Union Hospital, Fujian Medical University, 29 XinQuan Road, Fuzhou, 350001, People's Republic of China
| | | | | | | | | | | | | | | | | |
Collapse
|
22
|
Bansal NO, Prabhu S, Ware D, Shivapuje SK. Transcathater percutaneous device closure of a large PDA closed in a 3 kg infant. Indian Heart J 2014; 66:707-9. [PMID: 25634411 DOI: 10.1016/j.ihj.2014.12.002] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2014] [Revised: 06/26/2014] [Accepted: 12/03/2014] [Indexed: 11/16/2022] Open
Abstract
Patent ductus arteriosus (PDA) is common congenital heart disease which may require treatment as transcatheter percutaneous device closure (PDA device closure) or surgical ligation in symptomatic full-term patients. Surgical ligation is an invasive procedure and has more complications especially in the neonates. Problems in PDA device closure are difficult vascular access, manipulation of catheters and sheath, residual shunts, residual obstruction of major arteries etc and these complications increase in low birth weight babies, but it is a less invasive procedure and has fewer complications than surgery, so should be tried in low birth weight patients also. We are presenting a case of 3 kg infant with large PDA (8 mm) presented with failure to thrive, lower respiratory tract infection and heart failure. He successfully underwent PDA device closure with 10 × 12 mm Cocoon PDA device. To the best of our knowledge, this is the first case of the use of such a large device in a 3 kg child with good results.
Collapse
Affiliation(s)
- N O Bansal
- Prof. & HOD, Dept. of Cardiology, Grant Medical College & Sir J.J. Group of Hospitals, Byculla, Mumbai 400008, India; Asst. Prof., Dept. of Cardiology, Grant Medical College & Sir J.J. Group of Hospitals, Byculla, Mumbai 400008, India; Secretary, Cardiology Society of India (Mumbai Branch), India; Faculty, TCT, Asia Pacific 2009, South Korea; Interventional Cardiologist, Cumballa Hill Hospital, Mumbai, India
| | - Sandesh Prabhu
- Asst. Prof., Dept. of Cardiology, Grant Medical College & Sir J.J. Group of Hospitals, Byculla, Mumbai 400008, India
| | - Dhananjay Ware
- D. M. Resident, Dept. of Cardiology, Grant Medical College & Sir J.J. Group of Hospitals, Byculla, Mumbai 400008, India.
| | - Sanjaykumar K Shivapuje
- Asst. Prof., Dept. of Cardiology, Grant Medical College & Sir J.J. Group of Hospitals, Byculla, Mumbai 400008, India
| |
Collapse
|
23
|
Subramanian V, Kavassery Mahadevan K, Sivasubramonian S. Self-repositioning of an embolized patent ductus arteriosus device--a nightmare turned into sweet dreams. Catheter Cardiovasc Interv 2014; 85:1013-6. [PMID: 25381681 DOI: 10.1002/ccd.25725] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/18/2014] [Accepted: 11/03/2014] [Indexed: 11/12/2022]
Abstract
A 7-month-old boy was admitted for the device closure of symptomatic patent ductus arteriosus (PDA) with moderate pulmonary hypertension. The PDA measured 4.2 mm with adequate ampulla. It was closed with an 8-6 mm Heart R device from pulmonary artery (PA) end. Post extubation, the device embolized to proximal descending thoracic aorta just distal to PDA ampulla. While attempting to snare from the venous side, the device self-repositioned to PDA. It was stable thereafter and patient was discharged after 2 days. We report a complication, which got self-corrected.
Collapse
Affiliation(s)
- Venkateshwaran Subramanian
- Department of cardiology, Sreechitra Tirunal institute for medical sciences and technology, Thiruvananthapuram, Kerala, India
| | | | | |
Collapse
|
24
|
Behjati-Ardakani M, Behjati-Ardakani MA, Hadadzadeh M, Moshtaghion SH, Sarebanhassanabadi M. Experience with percutaneous closure of ductus arteriosus using the Amplatzer duct occluder in 243 consecutive patients and long-term results-A single centre study. Niger Med J 2014; 55:394-8. [PMID: 25298604 PMCID: PMC4178336 DOI: 10.4103/0300-1652.140379] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
Background: Percutaneous closure of patent ductus arteriosus (PDA) with Amplatzer duct occluder (ADO) has become increasingly popular in many cardiovascular centres. This study analysed the long-term results of percutaneous closure of PDA with ADO in a single centre. Materials and Methods: Between May 2004 and January 2013, 243 patients with median age of 2.5 years (range = 30 months to 38 years) and median weight of 10 Kg (range 4.5–80.5 Kg) underwent percutaneous closure of PDA using the ADO. The devices were implanted under fluoroscopic guidance. Patients were followed-up for any complications. Results: The mean diameter of narrow part of PDA was 6.4 ± 2.2 mm. The mean diameter of devices was 7.8 ± 2.3 mm. The devices were successfully implanted in 239 (98.3%) cases. At immediate, 1 day, 1, 6, 12 months and late follow-up, the complete occlusion rate was 33% (79 case), 97.1% (236 case), 97.5% (237 case), 98.3% (238 case), 98.3% (238 case) and 98.3% (238 case), respectively. Residual shunt remained in one case at late follow-up. The device embolisation occurred in five patients. The devices were successful retrieved in three patient and second larger devices were inserted. Two other devices were surgically retrieved and PDAs were ligated. Moderate left pulmonary artery stenosis (LPA) in one child and mild LPA stenosis in one infant were detected. Mild aortic obstruction occurred in one infant. Conclusions: Long-term follow-up of patients indicate that percutaneous closure of PDA using ADO is a safe and effective procedure. However, some complications, including device embolisation, left pulmonary stenosis and aortic obstruction may be observed in some cases.
Collapse
Affiliation(s)
| | | | - Mehdi Hadadzadeh
- Yazd Cardiovascular Research Center, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
| | | | | |
Collapse
|
25
|
Parra-Bravo JR, Osuna-Izaguirre MA, Beirana-Palencia L, Gálvez-Cancino F, Martínez-Monterrosas C, Lazo-Cárdenas C, Reyes-Vargas C. [Percutaneous closure of the patent ductus arteriosus in children with the Amplatzer Duct Occluder II]. ARCHIVOS DE CARDIOLOGIA DE MEXICO 2014; 84:171-6. [PMID: 24998666 DOI: 10.1016/j.acmx.2013.09.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2013] [Revised: 08/29/2013] [Accepted: 09/19/2013] [Indexed: 11/25/2022] Open
Abstract
INTRODUCTION In the last decades, several devices have been used for the percutaneous closure of patent ductus arteriosus, with its own limitations and risks. The Amplatzer Duct Occluder II has been designed to overcome those limitations and reduce risks. OBJECTIVE We described our initial series of patients who underwent percutaneous closure of patent ductus arteriosus with the Amplatzer Duct Occluder II, emphasis on the technical aspects of the procedure. METHODS We reviewed the clinical records of 9 patients with patent ductus arteriosus who underwent percutaneous closure with the Amplatzer Duct Occluder II. Median age was 24 months (range 8-51 months) and the median weight was 10.7kg (range 6-16.3kg). The minimal ductus arteriosus diameter was 2.7mm (1-5mm). RESULTS Implantation was successful in all cases. The devices most commonly used (33.3%) were the dimensions 4-4mm (3 patients), in 2 patients were used 3-4mm and in the rest of the patients were employed occluder other sizes. Four cases showed slight residual flow immediately after implantation. Total closure was achieved in 24h in 8 of 9 patients (89%). There was no embolization of the occluder or deaths during the procedure and we only observed one minor complication. CONCLUSIONS The Amplatzer Duct Occluder II in this series was effective in 89% of the patients at 24hs after the procedure and 100% follow-up. The implantation was safe and no major complications were observed. The occlusion rate is comparable to those reported for the Amplatzer Duct Occluder I.
Collapse
Affiliation(s)
- José Rafael Parra-Bravo
- Servicio de Cardiología, Hospital de Pediatría Centro Médico Nacional Siglo XXI, Instituto Mexicano del Seguro Social, Distrito Federal, México.
| | - Manuel Alfredo Osuna-Izaguirre
- Servicio de Pediatría, Hospital de Pediatría Centro Médico Nacional Siglo XXI, Instituto Mexicano del Seguro Social, Distrito Federal, México
| | - Luisa Beirana-Palencia
- Servicio de Cardiología, Hospital de Pediatría Centro Médico Nacional Siglo XXI, Instituto Mexicano del Seguro Social, Distrito Federal, México
| | - Franco Gálvez-Cancino
- Servicio de Pediatría, Hospital de Pediatría Centro Médico Nacional Siglo XXI, Instituto Mexicano del Seguro Social, Distrito Federal, México
| | - Christian Martínez-Monterrosas
- Servicio de Pediatría, Hospital de Pediatría Centro Médico Nacional Siglo XXI, Instituto Mexicano del Seguro Social, Distrito Federal, México
| | - César Lazo-Cárdenas
- Servicio de Cardiología, Hospital de Pediatría Centro Médico Nacional Siglo XXI, Instituto Mexicano del Seguro Social, Distrito Federal, México
| | - César Reyes-Vargas
- Servicio de Pediatría, Hospital de Pediatría Centro Médico Nacional Siglo XXI, Instituto Mexicano del Seguro Social, Distrito Federal, México
| |
Collapse
|
26
|
Baykan A, Narin N, Özyurt A, Argun M, Pamukçu Ö, Onan SH, Sezer S, Baykan Z, Üzüm K. Do we need a femoral artery route for transvenous PDA closure in children with ADO-I? Anatol J Cardiol 2014; 15:242-7. [PMID: 25333978 PMCID: PMC5337062 DOI: 10.5152/akd.2014.5269] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
OBJECTIVE The standard procedure in percutaneous closure of patent ductus arteriosus (PDA) with Amplatzer duct occluder-I (ADO-I) is transvenous closure guided by aortic access through femoral artery. The current study aims to compare the procedures for PDA closure with ADO-I: only transvenous access with the standard procedure. METHODS This study was designed retrospectively and 101 pediatric patients were included. PDA closure was done by only femoral venous access in 19 of them (group 1), arterial and venous access used in 92 patients (group 2) between 2004 to 2012 years. The position of the device and residual shunt in group1 was evaluated by the guidance of the aortogram obtained during the return phase of the pulmonary artery injection and guidance of transthoracic echocardiography. Shapiro-Wilk's test, Mann-Whitney U, chi-squared tests were used for statistical comparison. RESULTS The procedure was successful in 18 (95%) patients in group 1 and 90 (98%) patients in group 2. Complications including the pulmonary artery embolization (n=1), protrusion to pulmonary artery (n=1), inguinal hematoma (n=3), bleeding (n=2) were only detected in group 2. In other words, while complications were observed in 7 (7.2%) patients in group 2, no minor/major complication was observed in group 1. Complete closure in group 1 was: in catheterization room 14 (77.8%), at 24th hour in 2 (11.1%), at first month in 2 (11.1%). Complete closure in group 2 was: 66 (73.4%) patients in the catheterization room, 21 (23.3%) at 24th hour, 3 (3.3%) at first month, complete closure occurred at the end of first month. CONCLUSION In percutaneouse PDA closure via ADO-I, this technique can be a choice for patients whose femoral artery could not be accessed, or access is impossible/contraindicated. But for the reliability and validity of this method, randomized multicenter clinical studies are necessary.
Collapse
Affiliation(s)
- Ali Baykan
- Department of Peadiatric Cardiology, Faculty of Medicine, Erciyes University; Kayseri-Turkey.
| | | | | | | | | | | | | | | | | |
Collapse
|
27
|
Bruckheimer E, Godfrey M, Dagan T, Levinzon M, Amir G, Birk E. The Amplatzer duct occluder II additional sizes device for transcatheter PDA closure: Initial experience. Catheter Cardiovasc Interv 2014; 83:1097-101. [DOI: 10.1002/ccd.25445] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/06/2013] [Revised: 12/28/2013] [Accepted: 02/08/2014] [Indexed: 11/06/2022]
Affiliation(s)
- Elchanan Bruckheimer
- Section of Pediatric Cardiology; Schneider Children's Medical Center of Israel; Petach Tikva Israel
| | - Max Godfrey
- Section of Pediatric Cardiology; Schneider Children's Medical Center of Israel; Petach Tikva Israel
| | - Tamir Dagan
- Section of Pediatric Cardiology; Schneider Children's Medical Center of Israel; Petach Tikva Israel
| | - Michael Levinzon
- Section of Pediatric Anesthesiology; Schneider Children's Medical Center of Israel; Petach Tikva Israel
| | - Gabriel Amir
- Section of Pediatric Cardiothoracic Surgery; Schneider Children's Medical Center of Israel; Petach Tikva Israel
| | - Einat Birk
- Section of Pediatric Cardiology; Schneider Children's Medical Center of Israel; Petach Tikva Israel
| |
Collapse
|
28
|
Ahmadi A, Sabri M, Bigdelian H, Dehghan B, Gharipour M. Comparison of cost-effectiveness and postoperative outcome of device closure and open surgery closure techniques for treatment of patent ductus arteriosus. ARYA ATHEROSCLEROSIS 2014; 10:37-40. [PMID: 24963312 PMCID: PMC4063518] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Subscribe] [Scholar Register] [Received: 10/09/2013] [Accepted: 12/04/2013] [Indexed: 11/03/2022]
Abstract
BACKGROUND Various devices have been recently employed for percutaneous closure of the patent ductus arteriosus (PDA). Although the high effectiveness of device closure techniques has been clearly determined, a few studies have focused on the cost-effectiveness and also postoperative complications of these procedures in comparison with open surgery. The present study aimed to evaluate the clinical outcome and cost-effectiveness of PDA occlusion by Amplatzer and coil device in comparisong with open surgery. METHODS In this cross-sectional study, a randomized sample of 201 patients aged 1 month to 16 years (105 patients with device closure and 96 patients with surgical closure) was selected. The ratio of total pulmonary blood flow to total systemic blood flow, the Qp/Qs ratio, was measured using a pulmonary artery catheter. The cost analysis included direct medical care costs associated with device implantation and open surgery, as well as professional fees. All costs were calculated in Iranian Rials and then converted to US dollars. RESULTS There was no statistical difference in mean Qp/Qs ratio before the procedure between the device closure group and the open surgery group (2.1 ± 0.7 versus 1.7 ± 0.6, P = 0.090). The mean measured costs were overall higher in the device closure group than in open closure group (948.87 ± 548.76 US$ versus 743.70 ± 696.91 US$, P < 0.001). This difference remained significant after adjustment for age and gender (Standardized Beta = 0.160, P = 0.031). PDA closure with the Amplatzer ductal occluder (1053.05 ± 525.73 US$) or with Nit-Occlud coils (PFM) (912.73 ± 565.94 US$, P < 0.001) was more expensive than that via open surgery. However, the Cook detachable spring coils device closure (605.65 ± 194.62 US$, P = 0.650) had a non-significant cost difference with open surgery. No event was observed in the device closure group regarding in-hospital mortality or morbidity; however, in another group, 2 in-hospital deaths occurred, two patients experienced pneumonia and seizure, and one suffered electrolyte abnormalities including hyponatremia and hypocalcemia. CONCLUSION Although open surgery seems to be less expensive than device closure technique, because of lower mortality and morbidity, the latter group is more preferable.
Collapse
Affiliation(s)
- Alireza Ahmadi
- Assistant Professor, Isfahan Cardiovascular Research Centre, Isfahan Cardiovascular Research Institute, Isfahan University of Medical Sciences, Isfahan, Iran,Correspondence to: Alireza Ahmadi,
| | - Mohammadreza Sabri
- Professor, Department of Pediatrics, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
| | - Hamid Bigdelian
- Assistant Professor, Division of Cardiovascular Surgery, Department of Surgery, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
| | - Bahar Dehghan
- Fellow of Pediatric Cardiology, Department of Pediatrics, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
| | - Mojgan Gharipour
- PhD Candidate, Cardiac Rehabilitation Research Centre, Isfahan Cardiovascular Research Institute, Isfahan University of Medical Sciences, Isfahan, Iran
| |
Collapse
|
29
|
Behjati-Ardakani M, Behjati-Ardakani MA, Hosseini SH, Noori N. Long-term results of transcatheter closure of patent ductus arteriosus in infants using amplatzer duct occluder. IRANIAN JOURNAL OF PEDIATRICS 2013; 23:411-6. [PMID: 24427494 PMCID: PMC3883370] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/12/2012] [Accepted: 04/09/2013] [Indexed: 11/25/2022]
Abstract
OBJECTIVE Patent ductus arteriosus (PDA) is one of the most frequently seen congenital heart diseases. Its closure is recommended because of the risk of infective endocardis, as well as morbidity and mortality in the long. The aim of this study was to assess the long term results of the transcatheter closure of PDA in infants using amplatzer duct occlude (ADO). METHODS From May 2004 to September 2011, forty eight infants underwent transcatheter closure of PDA. A lateral or right anterior oblique view aortogram was done to locate PDA and to measure its size. Before discharge, repeat aortogram was performed to evaluate eventual residual shunt and to confirm the appropriate deployment of the ADO. Follow up evaluations were done with transthoracic echocardiography at discharge, 1 month, 6 months, 12 months and yearly thereafter. FINDINGS The mean age of patients at procedure was 9.18±2.32 (range 3 to 12) months, mean weight 6.73±1.16 (range 4.5 to 10.1) kg. The PDA occluded completely in 20 out of the 48 patients. Twenty four patients had trivial or mild shunt and two patients had moderate residual shunt which disappeared in one patient within 24 hours and other patient with moderate shunt in 1 month. One patient (age 8 months) had mild LPA stenosis. The device emobolization occurred in two patients, immediately after the procedure in one and during night in the other patient. CONCLUSION The long term results suggested that transcatheter closure of PDA using Amplatzer duct occluder is a safe and effective treatment in infants less than 1 year of age with minimal complications.
Collapse
Affiliation(s)
- Mostafa Behjati-Ardakani
- Yazd Cardiovascular Research Center, Shahid Sadoughi University of Medical sciences, Yazd, Iran,Corresponding Author:Address: Cardiovascular Research Center, Afshar Hospital, Jomhouri Boulevard, Yazd, Islamic Republic of Iran. E-mail:
| | | | | | - Noormohammad Noori
- Department of Pediatrics, Zahedan University of Medical Sciences, Zahedan, Iran
| |
Collapse
|
30
|
Sungur M, Karakurt C, Ozbarlas N, Baspinar O. Closure of patent ductus arteriosus in children, small infants, and premature babies with Amplatzer duct occluder II additional sizes: Multicenter study. Catheter Cardiovasc Interv 2013; 82:245-52. [DOI: 10.1002/ccd.24905] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/28/2012] [Revised: 02/19/2013] [Accepted: 02/26/2013] [Indexed: 11/09/2022]
Affiliation(s)
- Metin Sungur
- Department of Pediatric Cardiology; Ondokuz Mayis University; Samsun Turkey
| | - Cemsit Karakurt
- Department of Pediatric Cardiology; İnönü University; Malatya Turkey
| | - Nazan Ozbarlas
- Department of Pediatric Cardiology; Cukurova University; Adana Turkey
| | - Osman Baspinar
- Department of Pediatric Cardiology; Gaziantep University; Gaziantep Turkey
| |
Collapse
|
31
|
Bishnoi RN, Coulson JD, Ringel RE. Recent advances in interventional pediatric cardiology. Adv Pediatr 2013; 60:187-200. [PMID: 24007845 DOI: 10.1016/j.yapd.2013.04.009] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Affiliation(s)
- Ram N Bishnoi
- Department of Pediatric Cardiology, Johns Hopkins University School of Medicine, 1800 Orleans Street, Bloomberg Children's Center M2309, Baltimore, MD 21287, USA.
| | | | | |
Collapse
|
32
|
Baspinar O, Irdem A, Sivasli E, Sahin DA, Kilinc M. Comparison of the efficacy of different-sized Amplatzer duct occluders (I, II, and II AS) in children weighing less than 10 kg. Pediatr Cardiol 2013; 34:88-94. [PMID: 22648339 DOI: 10.1007/s00246-012-0393-6] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/08/2012] [Accepted: 05/09/2012] [Indexed: 10/28/2022]
Abstract
The transcatheter closure of patent ductus arteriosus (PDA) may cause more complications in small children. Amplatzer (St. Jude Medical, Plymouth, MN) has produces three types of devices for ductal occlusion: the Amplatzer duct occluder I (ADO I) and II (ADO II) and the recently introduced ADO II additional sizes (ADO II AS). We performed this study to determine the efficacy and complication rates in children who weigh <10 kg for the three types of devices used in our clinic. Between February 2007 and March 2012, 77 patients weighing <10 kg had their PDAs occluded with ADOs. The mean age of the patients was 0.76 ± 0.44 years (range 17 days-2 years), and their mean weight was 6.73 ± 2.05 (range 1.2-9.9) kg. In total, 54 girls (70.1 %) and 23 boys (29.9 %) with a mean pulmonary ductus diameter of 2.55 ± 1.0 (1.08-5.94) mm were included in the study. The ADO I was used in 26 patients (33.8 %); the ADO II was used in 43 patients (55.8 %); and the ADO II AS was used in 8 patients (10.4 %). The mean ages of patients with the ADO I, ADO II, and ADO II AS were 1.07 ± 0.48, 0.66 ± 0.31, and 0.28 ± 0.17 years (p < 0.05), respectively. Their mean weights were 7.86 ± 1.45, 6.50 ± 1.85, and 4.36 ± 2.49 kg (p < 0.05), respectively. Their mean narrowest ductal diameters were 3.11 ± 0.96, 2.25 ± 1.06, and 2.33 ± 1.01 mm (p < 0.05), respectively. The use of the ADO II and ADO II AS was found to be more common in type C defects. One patient with the ADO I and 5 patients with the ADO II (7.8 %) developed varying degrees of left pulmonary artery stenosis or iatrogenic aortic coarctation. In 1 patient, the ADO II AS was replaced with the ADO II due to a significant residual shunt observed during the procedure. Each of the ADOs has its own advantages and disadvantages. Although the ADO I is convenient for medium- and large-sized defects, the ADO II and ADO II AS can be used both anterogradely and retrogradely. The ADO II AS is safe and efficient to use in small infants.
Collapse
Affiliation(s)
- Osman Baspinar
- Pediatric Cardiology Department, Gaziantep University Medical Faculty, 27310 Gaziantep, Turkey.
| | | | | | | | | |
Collapse
|
33
|
Transcatheter closure of symptomatic arterial duct in infants younger than 1 year old. Pediatr Cardiol 2012; 33:1397-401. [PMID: 22639001 DOI: 10.1007/s00246-012-0356-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/02/2012] [Accepted: 04/27/2012] [Indexed: 10/28/2022]
Abstract
Transcatheter closure is currently considered the first-choice therapeutic option in patent arterial duct (AD), although this approach remains challenging in younger patients. To evaluate feasibility, safety, and mid-term efficacy of percutaneous AD closure using different devices in symptomatic infants <12 months old. Among the 483 patients who underwent transcatheter AD closure at our institution from April 2000 to January 2012, 69 were <12 months old. All patients showed cardiac overload at echocardiography, and 72 % of them were on anticongestive therapy. Based on ductal morphology and local anatomy, AD closure was attempted using detachable coils in 24 cases (group A) or the Amplatzer Duct Occluder (AGA Medical, Golden Valley, MN) device in 45 cases (group B). Procedural feasibility was 95.7 % without any difference between groups (95.8 % vs. 95.6 %, p = NS) as were fluoroscopy and procedural times. AD size was 2.5 ± 0.9 mm, and QP/QS ratio was 2.2 ± 1.1, with both being significantly higher in group B [2.1 ± 0.9 vs. 2.6 ± 0.9 mm (p = 0.04) and 1.7 ± 0.8 vs. 2.5 ± 1.2 (p = 0.009), respectively]. Overall complication rate was 1.5 %, without any difference between groups, as was the occlusion rate at hospital discharge (86 %) and over midterm follow-up (55 ± 36 months) (98.5 %). Percutaneous closure of symptomatic AD might be considered effective and safe in very young infants by tailoring the device choice to ductal morphology and local anatomy. In this setting, the controlled-release coil option was shown to be as effective as the ADO device during midterm follow-up.
Collapse
|
34
|
Al-Hamash SM, Wahab HA, Khalid ZH, Nasser IV. Transcatheter closure of patent ductus arteriosus using ado device: retrospective study of 149 patients. Heart Views 2012; 13:1-6. [PMID: 22754633 PMCID: PMC3385190 DOI: 10.4103/1995-705x.96658] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/03/2022] Open
Abstract
Background: Patent ductus arteriosus (PDA) is a common form of congenital heart disease and forms about 5-10% of congenital heart diseases. Surgical closure is safe and effective; however, certain patients may experience some morbidity. Recently, transcatheter closure of PDA using the Amplatzer duct occluder has been shown to be safe and efficacious. Objectives: To evaluate whether transcatheter closure with this device offers an alternative to surgical closure of PDA. Patients and Methods: Between July 2006 to July 2008, 149 patients (98 females and 51 males) with PDA underwent cardiac catheterization in an attempt to close their PDA by transcatheter approach using Amplatzer duct occluder device. Results: The patient's age ranged from 4 months to 45 years (median 5 years). Successful PDA closure was achieved in 136 patients (91.2%) with 100% complete closure rate within 24 hours after the procedure. Thirteen patients (8.7%) had unsuccessful attempts, 11 (7.3%) of them had failure of deployment of the device, while embolization of the device occurred in two of the patients (1.3%). Conclusions: Amplatzer duct occluder device is safe and effective for closure of different types and sizes of PDA with low rate of complication.
Collapse
Affiliation(s)
- Sadiq M Al-Hamash
- Department of Pediatric Cardiology, College of Medicine, Al-Mustansiriya University, Baghdad, Iraq
| | | | | | | |
Collapse
|
35
|
DRIGHIL ABDENASSER, AL JUFAN MANSOUR, AL OMRANE KHALID, AL ATTA JAMEEL, AL OMRANI AHMED, AL FADLEY FADEL. Safety of Transcatheter Patent Ductus Arteriosus Closure in Small Weight Infants. J Interv Cardiol 2012; 25:391-4. [DOI: 10.1111/j.1540-8183.2012.00733.x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
|
36
|
Tao K, Zhu D, An Q, Liu B, Lin K. Perventricular device closure of patent ductus arteriosus: a secondary chance. Ann Thorac Surg 2012; 93:1007-9. [PMID: 22365006 DOI: 10.1016/j.athoracsur.2011.10.047] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/08/2011] [Revised: 09/16/2011] [Accepted: 10/14/2011] [Indexed: 02/05/2023]
Abstract
Transcatheter closure is the mainstay of treatment for patent ductus arteriosus (PDA) in the pediatric patient but it is technically challenging and does not always succeed, especially in a younger age child with a large PDA. We present a technique of using a transesophageal echocardiogram-guided minimally invasive perventricular closure for the pediatric patient with a large PDA who failed transcatheter closure.
Collapse
Affiliation(s)
- Kaiyu Tao
- Department of Cardiovascular Surgery, West China Hospital, Sichuan University, Chengdu, Sichuan, People's Republic of China
| | | | | | | | | |
Collapse
|
37
|
Azhar AS, Abd El-Azim AA, Habib HS. Transcatheter closure of patent ductus arteriosus: Evaluating the effect of the learning curve on the outcome. Ann Pediatr Cardiol 2011; 2:36-40. [PMID: 20300267 PMCID: PMC2840760 DOI: 10.4103/0974-2069.52804] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Background and Objectives: Initial experience with transcatheter closure of patent ductus arteriosus (PDA) using detachable coils and Amplatzer duct occluder devices is reported. We evaluated the outcome, complications, and influence of the learning curve, and also assessed the need of surgical backup for such interventional procedures. Methods: From January 2000 to December 2004, 121 patients underwent transcatheter closure of PDA. Aortic angiogram was performed to evaluate the size, position, and shape of the duct for appropriately choosing the occluder device type and size. A second aortic angiogram was performed 10 minutes after device deployment. Echocardiography was repeated at intervals of 24 hours, then at 1, 3, and 6 months after the procedure to assess complications. Stepwise multiple regression analysis was used to assess the role of experience in improving the outcome of the procedure. Results: Of 121 cases, four patients had pulmonary artery embolization of the occluder device which was successfully retrieved in the catheterization laboratory, while two others had embolization that required surgical intervention. Four patients had temporary residual leak, nine had protrusion of the device into the aorta without significant Doppler pressure gradient or hemolysis on follow-up, and five had partial hemodynamically insignificant obstruction to the left pulmonary artery. Statistical analysis showed that the effect of the learning curve and experience was responsible for 93% improvement in the procedural outcome over the five-year study period. Conclusion: Transcatheter occlusion of PDA is safe and effective alternative to surgery. Complications occurred in those with unfavorable duct anatomy and with the use of multiple coils. Surgical backup was important for such interventional procedures. Experience played a major role in the proper choice of device type and size which greatly influenced the outcome of the procedure.
Collapse
Affiliation(s)
- Ahmad S Azhar
- Department of Pediatric Cardiology, The International Medical Center, Jeddah, Saudi Arabia
| | | | | |
Collapse
|
38
|
Dimas VV, Takao C, Ing FF, Mattamal R, Nugent AW, Grifka RG, Mullins CE, Justino H. Outcomes of transcatheter occlusion of patent ductus arteriosus in infants weighing ≤ 6 kg. JACC Cardiovasc Interv 2011; 3:1295-9. [PMID: 21232725 DOI: 10.1016/j.jcin.2010.08.022] [Citation(s) in RCA: 60] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/11/2010] [Revised: 08/06/2010] [Accepted: 08/20/2010] [Indexed: 10/18/2022]
Abstract
OBJECTIVES We sought to analyze the outcomes of transcatheter patent ductus arteriosus (PDA) occlusion using a variety of devices in infants weighing ≤6 kg. BACKGROUND Indications for transcatheter closure of a PDA in infancy include congestive heart failure and/or failure to thrive. Devices available for small infants may be problematic for various reasons, including sheath size, stiffness of delivery system, and anchoring and retrievability characteristics of the device. The Amplatzer Ductal Occluder is approved by U.S. Food and Drug Administration for children weighing >6 kg and older than 6 months of age. METHODS We performed a multicenter, retrospective analysis of children weighing ≤6 kg in whom transcatheter PDA occlusion was attempted between January 1995 and November 2005 at Texas Children's Hospital and January 2001 to November 2005 at Children's Hospital of San Diego. RESULTS A total of 62 patients underwent attempted closure. The mean age at catheterization was 4.7 ± 2.8 months with a mean weight at catheterization of 4.6 ± 0.9 kg. Successful device placement was achieved in 58 of 62 patients (94%). Among those receiving a device, complete occlusion was noted in all 58 patients at either catheterization or last available follow-up. CONCLUSIONS Percutaneous closure of PDA should be considered even in infants ≤6 kg.
Collapse
Affiliation(s)
- V Vivian Dimas
- Lillie Frank Abercrombie Section of Cardiology, Texas Children's Hospital, Baylor College of Medicine, 6621 Fannin, Houston, TX 77030, USA
| | | | | | | | | | | | | | | |
Collapse
|
39
|
Park YA, Kim NK, Park SJ, Yun BS, Choi JY, Sul JH. Clinical outcome of transcatheter closure of patent ductus arteriosus in small children weighing 10 kg or less. KOREAN JOURNAL OF PEDIATRICS 2010; 53:1012-7. [PMID: 21253316 PMCID: PMC3021727 DOI: 10.3345/kjp.2010.53.12.1012] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/15/2010] [Revised: 10/08/2010] [Accepted: 10/26/2010] [Indexed: 11/27/2022]
Abstract
PURPOSE Transcatheter closure has become an effective therapy in most patients with patent ductus arteriosus (PDA). However, there are difficulties in transcatheter closure of PDA in small children. We reviewed clinical outcomes of transcatheter closure of PDA in children weighing less than 10 kg in a single center. METHODS Between January 2003 and December 2009, 314 patients with PDA underwent transcatheter closure in our institute. Among them, 115 weighed less than 10 kg. All of these patients underwent transcatheter closure of PDA using either COOK Detachable Coil®, PFM Nit-Occlud®, or Amplatzer duct occluder®. A retrospective review of the treatment results and complications was performed. RESULTS The mean age of patients was 9.1±5.9 months (median, 8 months), and mean weight was 7.6±1.8 kg (median, 7.8 kg). The mean diameter of PDA was 3.2±1.4 mm (median, 3 mm). Complete occlusion occurred in 113 patients (98%). One patient was sent to surgery because of a failed attempt at device closure, and another patient had a small residual shunt after device placement. The average mean length of hospital stay was 3.0±3.3 days, and mean follow-up duration was 21.0±19.6 months. There were no major complications in any of the patients. CONCLUSION Transcatheter closure of PDA is considered safe and efficacious in infants weighing less than 10 kg. With sufficient experience and further effort, transcatheter closure of PDA can be accepted as the gold standard of treatment for this group of patients.
Collapse
Affiliation(s)
- Young A Park
- Division of Pediatric Cardiology, Severance Cardiovascular Hospital, Yonsei University Health System, Seoul, Korea
| | | | | | | | | | | |
Collapse
|
40
|
Abstract
We report a development of severe haemolysis after complete transcatheter closure of patent arterial duct. Aortography and echocardiography revealed no signs of residual shunt. Haemolysis occurred a day after the implantation. Aortography was performed and the extrusion of coil in aorta was evident. The extruded part of the coil was surgically removed. No signs of haemolysis remained.
Collapse
|
41
|
Rueda Núñez F, Avila Alvarez A, Fernández Trisac JL, Abelleira Pardeiro C. Percutaneous closure of patent ductus arteriosus in preterm infants. Rev Esp Cardiol 2010; 63:740-1. [PMID: 20515633 DOI: 10.1016/s1885-5857(10)70150-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
42
|
Cierre percutáneo del ductus arterioso persistente en el neonato prematuro. Rev Esp Cardiol (Engl Ed) 2010; 63:740-1. [DOI: 10.1016/s0300-8932(10)70168-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
43
|
Trefz M, Wilson N, Acton R, Hess DJ, Bass JL. Echocardiographic Assessment of Ductal Anatomy in Premature Infants-Lessons for Device Design. Echocardiography 2010; 27:575-9. [DOI: 10.1111/j.1540-8175.2009.01048.x] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
|
44
|
Polat TB, Celebi A, Hacımahmutoglu S, Akdeniz C, Erdem A, Fırat F. Lung perfusion studies after transcatheter closure of persistent ductus arteriosus with the Amplatzer duct occluder. Catheter Cardiovasc Interv 2010; 76:418-24. [DOI: 10.1002/ccd.22554] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
45
|
Wang JK, Wu MH, Lin MT, Chiu SN, Chen CA, Chiu HH. Transcatheter Closure of Moderate-to-Large Patent Ductus Arteriosus in Infants Using Amplatzer Duct Occluder. Circ J 2010; 74:361-4. [DOI: 10.1253/circj.cj-09-0473] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Jou-Kou Wang
- Department of Pediatrics, National Taiwan University Hospital, College of Medicine, National Taiwan University
| | - Mei-Hwan Wu
- Department of Pediatrics, National Taiwan University Hospital, College of Medicine, National Taiwan University
| | - Ming-Tai Lin
- Department of Pediatrics, National Taiwan University Hospital, College of Medicine, National Taiwan University
| | - Shuenn-Nan Chiu
- Department of Pediatrics, National Taiwan University Hospital, College of Medicine, National Taiwan University
| | - Chun-An Chen
- Department of Pediatrics, National Taiwan University Hospital, College of Medicine, National Taiwan University
| | - Hsin-Hui Chiu
- Department of Pediatrics, National Taiwan University Hospital, College of Medicine, National Taiwan University
| |
Collapse
|
46
|
Tratamiento percutáneo de la comunicación interauricular, la comunicación interventricular muscular y el ductus arterioso permeable en niños menores de un año. Rev Esp Cardiol 2009. [DOI: 10.1016/s0300-8932(09)72104-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
47
|
Gruenstein DH, Bass JL. Experimental evaluation of a new articulated Amplatzer® ductal occluder device without fabric. Catheter Cardiovasc Interv 2009; 74:482-7. [DOI: 10.1002/ccd.22059] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
48
|
Prada F, Mortera C, Bartrons J, Rissech M, Jiménez L, Carretero J, Llevadias J, Araica M. Percutaneous treatment of atrial septal defects, muscular ventricular septal defects and patent ductus arteriosus in infants under one year of age. Rev Esp Cardiol 2009; 62:1050-4. [PMID: 19712627 DOI: 10.1016/s1885-5857(09)73272-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
Amplatzer devices are used for the percutaneous closure of ostium secundum atrial septal defects, muscular ventricular septal defects and patent ductus arteriosus. However, very little experience has been gained in using these devices in infants under 1 year of age. Between January 2001 and January 2008, 22 symptomatic infants aged under 1 year underwent percutaneous treatment: three had an ostium secundum atrial septal defect, 15 had patent ductus arteriosus, and four had a muscular ventricular septal defect. All the procedures were completed successfully. No immediate or medium-term complications were observed. Closure of these types of defect using an Amplatzer device in infants under 1 year of age, who would otherwise require surgery, is a safe and effective procedure.
Collapse
Affiliation(s)
- Fredy Prada
- Servicio de Cardiología, Hospital Sant Joan de Déu, Esplugues de Llobregat, Barcelona, España.
| | | | | | | | | | | | | | | |
Collapse
|
49
|
Percutaneous closure of a patent arterial duct in a newborn. Cardiol Young 2009; 19:400-2. [PMID: 19442317 DOI: 10.1017/s1047951109004132] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
We report a successful percutaneous neonatal closure of haemodynamically significant patent arterial duct. The neonate was suffering multiorgan failure, and had complete atrioventricular block. Closure of the patent arterial duct, either with surgery or inhibitors of cyclooxygenase, was contraindicated. We inserted the Amplatzer Duct Occluder II, showing that percutaneous closure of a patent arterial duct is now feasible in critically ill neonates.
Collapse
|
50
|
Parra-Bravo R, Cruz-Ramírez A, Rebolledo-Pineda V, Robles-Cervantes J, Chávez-Fernández A, Beirana-Palencia L, Jiménez-Montufar L, de Jesús Estrada-Loza M, Estrada-Flores J, Báez-Zamudio N, Escobar-Ponce M. Cierre transcatéter del conducto arterioso persistente con dispositivo de Amplatzer en niños menores de un año. Rev Esp Cardiol 2009; 62:867-74. [DOI: 10.1016/s0300-8932(09)72069-x] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2008] [Accepted: 05/05/2009] [Indexed: 10/18/2022]
|