Matsuo T, Kusano M, Uchida R, Tsuda T, Toritsuka Y. Anatomical rectangular tunnel anterior cruciate ligament reconstruction provides excellent clinical outcomes.
Knee Surg Sports Traumatol Arthrosc 2022;
30:1396-1403. [PMID:
34014338 DOI:
10.1007/s00167-021-06609-5]
[Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/22/2021] [Accepted: 05/05/2021] [Indexed: 10/21/2022]
Abstract
PURPOSE
The purpose of this study was to prospectively evaluate the clinical outcomes following anatomical rectangular tunnel anterior cruciate ligament (ACL) reconstruction with a bone-patellar tendon-bone (BTB) graft using an adjustable-length femoral cortical fixation device with enough patients and a high follow-up rate.
METHODS
This study included 125 patients who underwent anatomical rectangular tunnel ACL reconstruction with a BTB graft. A BTB TightRope® was used for femoral graft fixation. Clinical evaluations were performed more than 2 years after surgery using the International Knee Documentation Committee (IKDC) Form. Patients interviewed by telephone were only subjectively evaluated. The side-to-side difference in anterior laxity at a manual maximum force was measured using the KT-2000 Arthrometer®.
RESULTS
Among the 125 patients, 99 were ultimately included and 26 were lost to follow-up (follow-up rate: 79%). Eight patients had re-tear (re-tear rate: 8%) and six patients had ACL injuries to the contralateral knee. Three patients did not follow our rehabilitation programme. One patient suffered septic arthritis. These 18 patients were considered ineligible for clinical evaluations. Therefore, clinical evaluations were performed in 81 of the 99 patients (64 were available for direct follow-up and 17 were available for a telephone interview). The follow-up period was 30 ± 10 months (range 24-68 months). According to the IKDC subjective assessment, 48 (59%) and 33 (41%) knees were graded as normal and nearly normal, respectively. A loss of extension (3°-5°) was observed in five patients (8%), whereas one patient (2%) exhibited a loss of flexion (3°-5°). The Lachman test was negative in 63 patients (98%). The pivot shift test was negative in 59 patients (92%). The side-to-side difference in KT value was 0.4 ± 0.7 mm (range - 1-4 mm).
CONCLUSION
Anatomical rectangular tunnel ACL reconstruction with a BTB graft using an adjustable-length femoral cortical fixation device provided excellent clinical outcomes both subjectively and objectively more than 2 years after surgery, whereas 8 of the 99 patients had re-tear of the graft. The adjustable-length femoral cortical fixation device could be safely used in anatomical rectangular tunnel ACL reconstruction with a BTB graft.
LEVEL OF EVIDENCE
III.
Collapse