Spiral flow-generating tube for saline chaser improves aortic enhancement in Gd-EOB-DTPA-enhanced hepatic MRI.
Eur Radiol 2018;
29:2009-2016. [PMID:
30255255 DOI:
10.1007/s00330-018-5733-3]
[Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2018] [Revised: 08/11/2018] [Accepted: 08/28/2018] [Indexed: 12/22/2022]
Abstract
OBJECTIVES
To evaluate the effect of a spiral tube on contrast enhancement in the hepatic arterial phase (HAP) of gadoxetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI).
METHODS
In this retrospective study, we observed 104 patients who underwent dynamic MRI of the liver between October 2017 and December 2017. Three Gd-EOB-DTPA injection protocols were compared: (A) conventional method (undiluted Gd-EOB-DTPA, injection rate 1 ml/s, n = 36); (B) spiral dilution method (1:1 diluted Gd-EOB-DTPA with saline [off-label], injection rate 2 ml/s via spiral tube, n = 38); (C) spiral-flushed method (undiluted Gd-EOB-DTPA, injection rate 1 ml/s via spiral tube, n = 30). We regarded protocol-A as a control. The signal-to-noise ratio (SNR) of the abdominal aorta was calculated using arterial phase images. Image contrast and artefacts were evaluated by two board-certified radiologists, using a four-point scale. Statistical analyses included Dunnett's test, the Kruskal-Wallis test and the Steel test.
RESULTS
The SNR of the aorta was significantly higher with protocol-C (25.4 ± 8.8) than protocol-A (20.8 ± 5.4, p = 0.01). There was no significant difference in SNR between protocols A and B (p = 0.47). The contrast score of protocol-C was significantly higher than that of protocol-A (p = 0.0019). There was no significant difference in contrast score between protocols A and B (p = 0.50). There was no significant difference in artefacts among the three protocols (p = 0.96).
CONCLUSIONS
Use of a spiral tube with a slow injection protocol contributed to improved aortic contrast enhancement in the HAP of GD-EOB-DTPA-enhanced hepatic MRI.
KEY POINTS
• Gadoxetic acid shows weaker arterial enhancement at recommended doses, compared with nonspecific gadolinium agents; selection of an appropriate injection protocol is important. • A spiral flow-generating tube improves the transport efficiency of the contrast media, and increases the signal-to-noise ratio of the aorta in hepatic arterial phase. • A spiral flow-generating tube does not contribute to artefact reduction in hepatic arterial phase.
Collapse