1
|
Singh G, Chanda A. Mechanical properties of whole-body soft human tissues: a review. Biomed Mater 2021; 16. [PMID: 34587593 DOI: 10.1088/1748-605x/ac2b7a] [Citation(s) in RCA: 78] [Impact Index Per Article: 26.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2021] [Accepted: 09/29/2021] [Indexed: 11/11/2022]
Abstract
The mechanical properties of soft tissues play a key role in studying human injuries and their mitigation strategies. While such properties are indispensable for computational modelling of biological systems, they serve as important references in loading and failure experiments, and also for the development of tissue simulants. To date, experimental studies have measured the mechanical properties of peripheral tissues (e.g. skin)in-vivoand limited internal tissuesex-vivoin cadavers (e.g. brain and the heart). The lack of knowledge on a majority of human tissues inhibit their study for applications ranging from surgical planning, ballistic testing, implantable medical device development, and the assessment of traumatic injuries. The purpose of this work is to overcome such challenges through an extensive review of the literature reporting the mechanical properties of whole-body soft tissues from head to toe. Specifically, the available linear mechanical properties of all human tissues were compiled. Non-linear biomechanical models were also introduced, and the soft human tissues characterized using such models were summarized. The literature gaps identified from this work will help future biomechanical studies on soft human tissue characterization and the development of accurate medical models for the study and mitigation of injuries.
Collapse
Affiliation(s)
- Gurpreet Singh
- Centre for Biomedical Engineering, Indian Institute of Technology (IIT), Delhi, India
| | - Arnab Chanda
- Centre for Biomedical Engineering, Indian Institute of Technology (IIT), Delhi, India.,Department of Biomedical Engineering, All India Institute of Medical Sciences (AIIMS), Delhi, India
| |
Collapse
|
2
|
Chanda A, Unnikrishnan V, Lackey K, Robbins J. Biofidelic conductive soft tissue surrogates. INT J POLYM MATER PO 2019. [DOI: 10.1080/00914037.2018.1552856] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Affiliation(s)
- Arnab Chanda
- Department of Aerospace Engineering, The University of Alabama, Tuscaloosa, Alabama, USA
| | - Vinu Unnikrishnan
- Department of Aerospace Engineering, The University of Alabama, Tuscaloosa, Alabama, USA
| | - Kim Lackey
- Department of Biological Sciences, The University of Alabama, Tuscaloosa, Alabama, USA
| | - Joseph Robbins
- Department of Mechanical Engineering, The University of Alabama, Tuscaloosa, Alabama, USA
| |
Collapse
|
3
|
Chanda A, McClain S. Mechanical Modeling of Healthy and Diseased Calcaneal Fat Pad Surrogates. Biomimetics (Basel) 2019; 4:E1. [PMID: 31105187 PMCID: PMC6477669 DOI: 10.3390/biomimetics4010001] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2018] [Revised: 11/16/2018] [Accepted: 12/19/2018] [Indexed: 11/16/2022] Open
Abstract
The calcaneal fat pad is a major load bearing component of the human foot due to daily gait activities such as standing, walking, and running. Heel and arch pain pathologies such as plantar fasciitis, which over one third of the world population suffers from, is a consequent effect of calcaneal fat pad damage. Also, fat pad stiffening and ulceration has been observed due to diabetes mellitus. To date, the biomechanics of fat pad damage is poorly understood due to the unavailability of live human models (because of ethical and biosafety issues) or biofidelic surrogates for testing. This also precludes the study of the effectiveness of preventive custom orthotics for foot pain pathologies caused due to fat pad damage. The current work addresses this key gap in the literature with the development of novel biofidelic surrogates, which simulate the in vivo and in vitro compressive mechanical properties of a healthy calcaneal fat pad. Also, surrogates were developed to simulate the in vivo mechanical behavior of the fat pad due to plantar fasciitis and diabetes. A four-part elastomeric material system was used to fabricate the surrogates, and their mechanical properties were characterized using dynamic and cyclic load testing. Different strain (or displacement) rates were tested to understand surrogate behavior due to high impact loads. These surrogates can be integrated with a prosthetic foot model and mechanically tested to characterize the shock absorption in different simulated gait activities, and due to varying fat pad material property in foot pain pathologies (i.e., plantar fasciitis, diabetes, and injury). Additionally, such a foot surrogate model, fitted with a custom orthotic and footwear, can be used for the experimental testing of shock absorption characteristics of preventive orthoses.
Collapse
Affiliation(s)
- Arnab Chanda
- Department of Bioengineering, University of Pittsburgh, PA 15213, USA.
- Department of Aerospace Engineering and Mechanics, University of Alabama, AL 35401, USA.
| | - Stephen McClain
- Department of Aerospace Engineering and Mechanics, University of Alabama, AL 35401, USA.
- Department of Biomedical Engineering, Georgia Institute of Technology, GA 30332, USA.
| |
Collapse
|
4
|
Abstract
Skin injury is the most common type of injury, which manifests itself in the form of wounds and cuts. A minor wound repairs itself within a short span of time. However, deep wounds require adequate care and sometime clinical interventions such as surgical suturing for their timely closure and healing. In literature, mechanical properties of skin and other tissues are well known. However, the anisotropic behavior of wounded skin has not been studied yet, specifically with respect to localized overstraining and possibilities of rupture. In the current work, the biomechanics of common skin wound geometries were studied with a biofidelic skin phantom, using uniaxial mechanical testing and Digital Image Correlation (DIC). Global and local mechanical properties were investigated, and possibilities of rupture due to localized overstraining were studied across different wound geometries and locations. Based on the experiments, a finite element (FE) model was developed for a common elliptical skin wound geometry. The fidelity of this FE model was evaluated with simulation of uniaxial tension tests. The induced strain distributions and stress-stretch responses of the FE model correlated very well with the experiments (R2 > 0.95). This model would be useful for prediction of the mechanical response of common wound geometries, especially with respect to their chances of rupture due to localized overstraining. This knowledge would be indispensable for pre-surgical planning, and also in robotic surgeries, for selection of appropriate wound closure techniques, which do not overstrain the skin tissue or initiate tearing.
Collapse
|
5
|
Chanda A, Ruchti T, Upchurch W. Biomechanical Modeling of Prosthetic Mesh and Human Tissue Surrogate Interaction. Biomimetics (Basel) 2018; 3:E27. [PMID: 31105249 PMCID: PMC6352698 DOI: 10.3390/biomimetics3030027] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2018] [Revised: 09/09/2018] [Accepted: 09/13/2018] [Indexed: 11/30/2022] Open
Abstract
Surgical repair of hernia and prolapse with prosthetic meshes are well-known to cause pain, infection, hernia recurrence, and mesh contraction and failures. In literature, mesh failure mechanics have been studied with uniaxial, biaxial, and cyclic load testing of dry and wet meshes. Also, extensive experimental studies have been conducted on surrogates, such as non-human primates and rodents, to understand the effect of mesh stiffness, pore size, and knitting patterns on mesh biocompatibility. However, the mechanical properties of such animal tissue surrogates are widely different from human tissues. Therefore, to date, mechanics of the interaction between mesh and human tissues is poorly understood. This work addresses this gap in literature by experimentally and computationally modeling the biomechanical behavior of mesh, sutured to human tissue phantom under tension. A commercially available mesh (Prolene®) was sutured to vaginal tissue phantom material and tested at different uniaxial strains and strain rates. Global and local stresses at the tissue phantom, suture, and mesh were analyzed. The results of this study provide important insights into the mechanics of prosthetic mesh failure and will be indispensable for better mesh design in the future.
Collapse
Affiliation(s)
- Arnab Chanda
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15213, USA.
- Department of Aerospace Engineering and Mechanics, University of Alabama, Tuscaloosa, AL 35401, USA.
| | - Tysum Ruchti
- Department of Mechanical Engineering, Brigham Young University, Provo, UT 84602, USA.
| | - Weston Upchurch
- Department of Aerospace Engineering and Mechanics, University of Alabama, Tuscaloosa, AL 35401, USA.
- Department of Surgery, University of Minnesota, Minneapolis, MN 55455, USA.
| |
Collapse
|
6
|
Human Skin-Like Composite Materials for Blast Induced Injury Mitigation. JOURNAL OF COMPOSITES SCIENCE 2018. [DOI: 10.3390/jcs2030044] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
Armors and military grade personal protection equipment (PPE) materials to date are bulky and are not designed to effectively mitigate blast impacts. In the current work, a human skin-like castable simulant material was developed and its blast mitigation characteristics (in terms of induced stress reduction at the bone and muscles) were characterized in the presence of composite reinforcements. The reinforcement employed was Kevlar 129 (commonly used in advanced combat helmets), which was embedded within the novel skin simulant material as the matrix and used to cover a representative extremity based human skin, muscle and bone section finite element (FE) model. The composite variations tested were continuous and short-fiber types, lay-ups (0/0, 90/0, and 45/45 orientations) and different fiber volume fractions. From the analyses, the 0/0 continuous fiber lay-up with a fiber volume fraction close to 0.1 (or 10%) was found to reduce the blast-induced dynamic stresses at the bone and muscle sections by 78% and 70% respectively. These findings indicate that this novel skin simulant material with Kevlar 129 reinforcement, with further experimental testing, may present future opportunities in blast resistant armor padding designing.
Collapse
|
7
|
Chanda A. Biomechanical Modeling of Human Skin Tissue Surrogates. Biomimetics (Basel) 2018; 3:biomimetics3030018. [PMID: 31105240 PMCID: PMC6352690 DOI: 10.3390/biomimetics3030018] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2018] [Revised: 07/16/2018] [Accepted: 07/19/2018] [Indexed: 11/22/2022] Open
Abstract
Surrogates, which precisely simulate nonlinear mechanical properties of the human skin at different body sites, would be indispensable for biomechanical testing applications, such as estimating the accurate load response of skin implants and prosthetics to study the biomechanics of static and dynamic loading conditions on the skin, dermatological and sports injuries, and estimating the dynamic load response of lethal and nonlethal ballistics. To date, human skin surrogates have been developed mainly with materials, such as gelatin and polydimethylsiloxane (PDMS), based on assumption of simplified mechanical properties, such as an average elastic modulus (estimated through indentation tests), and Poisson’s ratio. In addition, pigskin and cowhides, which have widely varying mechanical properties, have been used to simulate human skin. In the current work, a novel elastomer-based material system is developed, which precisely mimics the nonlinear stress–stretch behavior, elastic modulus at high and low strains, and fracture strengths of the natural human skin at different body sites. The manufacturing and fabrication process of these skin surrogates are discussed, and mechanical testing results are presented.
Collapse
Affiliation(s)
- Arnab Chanda
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15213, USA.
- Department of Aerospace Engineering and Mechanics, University of Alabama, Tuscaloosa, AL 35401, USA.
| |
Collapse
|
8
|
Tissue Anisotropy Modeling Using Soft Composite Materials. Appl Bionics Biomech 2018; 2018:4838157. [PMID: 29853996 PMCID: PMC5966707 DOI: 10.1155/2018/4838157] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2018] [Accepted: 04/11/2018] [Indexed: 11/22/2022] Open
Abstract
Soft tissues in general exhibit anisotropic mechanical behavior, which varies in three dimensions based on the location of the tissue in the body. In the past, there have been few attempts to numerically model tissue anisotropy using composite-based formulations (involving fibers embedded within a matrix material). However, so far, tissue anisotropy has not been modeled experimentally. In the current work, novel elastomer-based soft composite materials were developed in the form of experimental test coupons, to model the macroscopic anisotropy in tissue mechanical properties. A soft elastomer matrix was fabricated, and fibers made of a stiffer elastomer material were embedded within the matrix material to generate the test coupons. The coupons were tested on a mechanical testing machine, and the resulting stress-versus-stretch responses were studied. The fiber volume fraction (FVF), fiber spacing, and orientations were varied to estimate the changes in the mechanical responses. The mechanical behavior of the soft composites was characterized using hyperelastic material models such as Mooney-Rivlin's, Humphrey's, and Veronda-Westmann's model and also compared with the anisotropic mechanical behavior of the human skin, pelvic tissues, and brain tissues. This work lays the foundation for the experimental modelling of tissue anisotropy, which combined with microscopic studies on tissues can lead to refinements in the simulation of localized fiber distribution and orientations, and enable the development of biofidelic anisotropic tissue phantom materials for various tissue engineering and testing applications.
Collapse
|