1
|
Talebibarmi P, Vahidi B, Ebad M. In silico analysis of embolism in cerebral arteries using fluid-structure interaction method. Heliyon 2024; 10:e30443. [PMID: 38720729 PMCID: PMC11077041 DOI: 10.1016/j.heliyon.2024.e30443] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2024] [Accepted: 04/26/2024] [Indexed: 05/12/2024] Open
Abstract
Ischemic stroke, particularly embolic stroke, stands as a significant global contributor to mortality and long-term disabilities. This paper presents a comprehensive simulation of emboli motion through the middle cerebral artery (MCA), a prevalent site for embolic stroke. Our patient-specific computational model integrates major branches of the middle cerebral artery reconstructed from magnetic resonance angiography images, pulsatile flow dynamics, and emboli of varying geometries, sizes, and material properties. The fluid-structure interactions method is employed to simulate deformable emboli motion through the middle cerebral artery, allowing observation of hemodynamic changes in artery branches upon embolus entry. We investigated the impact of embolus presence on shear stress magnitude on artery walls, analyzed the effects of embolus material properties and geometries on embolus trajectory and motion dynamics within the middle cerebral artery. Additionally, we evaluated the non-Newtonian behavior of blood, comparing it with Newtonian blood behavior. Our findings highlight that embolus geometry significantly influences trajectory, motion patterns, and hemodynamics within middle cerebral artery branches. Emboli with visco-hyperelastic material properties experienced higher stresses upon collision with artery walls compared to those with hyperelastic properties. Furthermore, considering blood as a non-Newtonian fluid had notable effects on emboli stresses and trajectories within the artery, particularly during collisions. Notably, the maximum von Mises stress experienced in our study was 21.83 kPa, suggesting a very low probability of emboli breaking during movement, impact, and after coming to a stop. However, in certain situations, the magnitude of shear stress on them exceeded 1 kPa, increasing the likelihood of cracking and disintegration. These results serve as an initial step in anticipating critical clinical conditions arising from arterial embolism in the middle cerebral artery. They provide insights into the biomechanical parameters influencing embolism, contributing to improved clinical decision-making for stroke management.
Collapse
Affiliation(s)
- Pouria Talebibarmi
- Division of Biomedical Engineering, Department of Life Science Engineering, Faculty of New Sciences and Technologies, University of Tehran, Tehran, Iran
| | - Bahman Vahidi
- Division of Biomedical Engineering, Department of Life Science Engineering, Faculty of New Sciences and Technologies, University of Tehran, Tehran, Iran
| | - Mahtab Ebad
- Division of Biomedical Engineering, Department of Life Science Engineering, Faculty of New Sciences and Technologies, University of Tehran, Tehran, Iran
| |
Collapse
|
2
|
Cheffar L, Benslimane A, Sadaoui D, Benchabane A, Bekkour K. Pulsatile flow of thixotropic blood in artery under external body acceleration. Comput Methods Biomech Biomed Engin 2022; 26:927-940. [PMID: 35852069 DOI: 10.1080/10255842.2022.2098677] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
This work presents a numerical technique for simulating non-Newtonian blood flow in human's arteries driven by an oscillating pressure gradient. The blood is considered as a thixotropic fluid and its structural properties are considered to obey Moore's thixotropic model as a constitutive equation. The equations of motion are simplified considering the flow laminar, axisymmetric and the fluid incompressible. A numerical solution is presented using finite difference method in order to compute the velocity field and wall shear stress distribution. The numerical results obtained have been validated with the analytical solution available in the literature. Furthermore, the effect of the structural properties, the average of the pressure gradient and the external acceleration on the velocity and wall shear stress distribution is investigated. These results reveal the influence of the different parameters studied on the pipe flow response of the thixotropic fluid.
Collapse
Affiliation(s)
- Louiza Cheffar
- Laboratoire de Mécanique, Matériaux et Energétique (L2ME), Faculté de Technologie, Université de Bejaia, Bejaia 06000, Algérie
| | - Abdelhakim Benslimane
- Laboratoire de Mécanique, Matériaux et Energétique (L2ME), Faculté de Technologie, Université de Bejaia, Bejaia 06000, Algérie
| | - Djamel Sadaoui
- Laboratoire de Mécanique, Matériaux et Energétique (L2ME), Faculté de Technologie, Université de Bejaia, Bejaia 06000, Algérie
| | - Adel Benchabane
- Laboratoire de Génie Energétique et Matériaux (LGEM), Faculté des Sciences et de la Technologie, Université Mohamed Khider -Biskra, BP 145, Biskra 07000, Algérie
- ICube Research Institute UMR 7357, CNRS, Université de Strasbourg, 2 Rue Boussingault, Strasbourg 67000, France
| | | |
Collapse
|
3
|
Mezali F, Benmamar S, Naima K, Ameur H, Rafik O. Evaluation of stent effect and thrombosis generation with different blood rheology on an intracranial aneurysm by the Lattice Boltzmann method. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2022; 219:106757. [PMID: 35338884 DOI: 10.1016/j.cmpb.2022.106757] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/26/2022] [Revised: 03/07/2022] [Accepted: 03/12/2022] [Indexed: 06/14/2023]
Abstract
BACKGROUND AND OBJECTIVE Treatment of intracranial aneurysms with flow-diverting stents prevents rupture by reducing blood flow and creating thrombosis within the aneurysm. This paper aims to assess the hemodynamic effect of placing stents with different struts (0, 3, 5, 7 struts) on intracranial aneurysms and to propose a simple prediction model of thrombosis zone without any further computational cost. METHOD Lattice Boltzmann method with different rheological models (Newtonian, Carreau-Yasuda, KL) of blood are used to study the hemodynamic effect of flow-diverting stents in the aneurysm. Pulsatile flow boundary conditions were applied in the inlet of the artery. The average Reynolds number was resulting Re = 111. The Lagrangian tracking of the particle was developed to assess the intra-aneurysmal blood stagnation. To predict the probable thrombose zone induced by flow-diverting stents, the shear rate threshold is utilized to determine the nodes of fluid to clot. RESULTS The results show that the flow patterns into the aneurysmal sac develop a vortex, decreasing after stent placement until disappearance for the stent with seven struts (porosity 71.4%). Velocity, shear rate, shear stress, trajectory, path length, and occlusion rate are compared before and after stent placement. These parameters decrease inversely with the porosity of the stent. The three models yield a closes result of the (velocity, shear rate, occlusion rate). Tracking the fluid-particle trajectory shows that the length of the particle paths decreases with the number of struts causing fluid to slow down and increase, consequently, the residence time into the sac. CONCLUSION The flow-diverting stents placement cause the reduction of dynamic flow within aneurysm. The reduction effect is almost the same below five struts (80% of porosity). The results show that, if our objective is restricted to estimating the hemodynamic effect, measured by (velocity, shear rate, occlusion rate), the differences between rheological behavior models are, practically, not significant, and the models can be used indifferently.
Collapse
Affiliation(s)
- Farouk Mezali
- Water Sciences Research laboratory: LRS-Eau, National Polytechnic School, El harrach, Algiers; Hydraulics department, Faculty of Technology-BP 166 M'sila 28000 Algeria.
| | - Saida Benmamar
- Water Sciences Research laboratory: LRS-Eau, National Polytechnic School, El harrach, Algiers.
| | - Khatir Naima
- Department of Technology, University Centre of Naama (Ctr Univ Naama), P.O. Box 66, Naama 45000, Algeria.
| | - Houari Ameur
- Department of Technology, University Centre of Naama (Ctr Univ Naama), P.O. Box 66, Naama 45000, Algeria.
| | - Ouared Rafik
- Water Sciences Research laboratory: LRS-Eau, National Polytechnic School, El harrach, Algiers
| |
Collapse
|
4
|
Berg P, Saalfeld S, Voß S, Beuing O, Janiga G. A review on the reliability of hemodynamic modeling in intracranial aneurysms: why computational fluid dynamics alone cannot solve the equation. Neurosurg Focus 2020; 47:E15. [PMID: 31261119 DOI: 10.3171/2019.4.focus19181] [Citation(s) in RCA: 47] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2019] [Accepted: 04/09/2019] [Indexed: 12/23/2022]
Abstract
Computational blood flow modeling in intracranial aneurysms (IAs) has enormous potential for the assessment of highly resolved hemodynamics and derived wall stresses. This results in an improved knowledge in important research fields, such as rupture risk assessment and treatment optimization. However, due to the requirement of assumptions and simplifications, its applicability in a clinical context remains limited.This review article focuses on the main aspects along the interdisciplinary modeling chain and highlights the circumstance that computational fluid dynamics (CFD) simulations are embedded in a multiprocess workflow. These aspects include imaging-related steps, the setup of realistic hemodynamic simulations, and the analysis of multidimensional computational results. To condense the broad knowledge, specific recommendations are provided at the end of each subsection.Overall, various individual substudies exist in the literature that have evaluated relevant technical aspects. In this regard, the importance of precise vessel segmentations for the simulation outcome is emphasized. Furthermore, the accuracy of the computational model strongly depends on the specific research question. Additionally, standardization in the context of flow analysis is required to enable an objective comparison of research findings and to avoid confusion within the medical community. Finally, uncertainty quantification and validation studies should always accompany numerical investigations.In conclusion, this review aims for an improved awareness among physicians regarding potential sources of error in hemodynamic modeling for IAs. Although CFD is a powerful methodology, it cannot provide reliable information, if pre- and postsimulation steps are inaccurately carried out. From this, future studies can be critically evaluated and real benefits can be differentiated from results that have been acquired based on technically inaccurate procedures.
Collapse
Affiliation(s)
- Philipp Berg
- 1Department of Fluid Dynamics and Technical Flows.,2Research CampusSTIMULATE, and
| | - Sylvia Saalfeld
- 2Research CampusSTIMULATE, and.,3Department of Simulation and Graphics, University of Magdeburg; and
| | - Samuel Voß
- 1Department of Fluid Dynamics and Technical Flows.,2Research CampusSTIMULATE, and
| | - Oliver Beuing
- 2Research CampusSTIMULATE, and.,4Department of Neuroradiology, University Hospital Magdeburg, Magdeburg, Germany
| | - Gábor Janiga
- 1Department of Fluid Dynamics and Technical Flows.,2Research CampusSTIMULATE, and
| |
Collapse
|
5
|
Berg P, Voß S, Janiga G, Saalfeld S, Bergersen AW, Valen-Sendstad K, Bruening J, Goubergrits L, Spuler A, Chiu TL, Tsang ACO, Copelli G, Csippa B, Paál G, Závodszky G, Detmer FJ, Chung BJ, Cebral JR, Fujimura S, Takao H, Karmonik C, Elias S, Cancelliere NM, Najafi M, Steinman DA, Pereira VM, Piskin S, Finol EA, Pravdivtseva M, Velvaluri P, Rajabzadeh-Oghaz H, Paliwal N, Meng H, Seshadhri S, Venguru S, Shojima M, Sindeev S, Frolov S, Qian Y, Wu YA, Carlson KD, Kallmes DF, Dragomir-Daescu D, Beuing O. Multiple Aneurysms AnaTomy CHallenge 2018 (MATCH)-phase II: rupture risk assessment. Int J Comput Assist Radiol Surg 2019; 14:1795-1804. [PMID: 31054128 DOI: 10.1007/s11548-019-01986-2] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2019] [Accepted: 04/23/2019] [Indexed: 01/10/2023]
Abstract
PURPOSE Assessing the rupture probability of intracranial aneurysms (IAs) remains challenging. Therefore, hemodynamic simulations are increasingly applied toward supporting physicians during treatment planning. However, due to several assumptions, the clinical acceptance of these methods remains limited. METHODS To provide an overview of state-of-the-art blood flow simulation capabilities, the Multiple Aneurysms AnaTomy CHallenge 2018 (MATCH) was conducted. Seventeen research groups from all over the world performed segmentations and hemodynamic simulations to identify the ruptured aneurysm in a patient harboring five IAs. Although simulation setups revealed good similarity, clear differences exist with respect to the analysis of aneurysm shape and blood flow results. Most groups (12/71%) included morphological and hemodynamic parameters in their analysis, with aspect ratio and wall shear stress as the most popular candidates, respectively. RESULTS The majority of groups (7/41%) selected the largest aneurysm as being the ruptured one. Four (24%) of the participating groups were able to correctly select the ruptured aneurysm, while three groups (18%) ranked the ruptured aneurysm as the second most probable. Successful selections were based on the integration of clinically relevant information such as the aneurysm site, as well as advanced rupture probability models considering multiple parameters. Additionally, flow characteristics such as the quantification of inflow jets and the identification of multiple vortices led to correct predictions. CONCLUSIONS MATCH compares state-of-the-art image-based blood flow simulation approaches to assess the rupture risk of IAs. Furthermore, this challenge highlights the importance of multivariate analyses by combining clinically relevant metadata with advanced morphological and hemodynamic quantification.
Collapse
Affiliation(s)
| | - Samuel Voß
- University of Magdeburg, Magdeburg, Germany
| | | | | | | | | | | | | | | | | | | | | | - Benjamin Csippa
- Budapest University of Technology and Economics, Budapest, Hungary
| | - György Paál
- Budapest University of Technology and Economics, Budapest, Hungary
| | - Gábor Závodszky
- Budapest University of Technology and Economics, Budapest, Hungary
| | | | | | | | | | | | | | - Saba Elias
- Houston Methodist Research Institute, Houston, TX, USA
| | | | | | | | | | - Senol Piskin
- The University of Texas at San Antonio, San Antonio, TX, USA
| | - Ender A Finol
- The University of Texas at San Antonio, San Antonio, TX, USA
| | | | | | | | | | - Hui Meng
- State University of New York, Buffalo, NY, USA
| | | | | | | | | | | | - Yi Qian
- Macquarie University, Sydney, Australia
| | | | | | | | | | | |
Collapse
|