1
|
Kesen S, Tokgöz N. Echo-planar DWI variants: A comparative study in vertebral marrow pathology. JOURNAL OF CLINICAL ULTRASOUND : JCU 2024. [PMID: 39198006 DOI: 10.1002/jcu.23779] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/05/2024] [Revised: 06/07/2024] [Accepted: 07/22/2024] [Indexed: 09/01/2024]
Abstract
PURPOSE Single-shot echo-planar imaging (ss-EPI) has limited application in vertebral column imaging due to numerous artifacts. Therefore, we aimed to compare readout-segmented echo-planar imaging (rs-EPI) to ss-EPI and assess its value in the differential diagnosis of vertebral infectious, tumoral infiltrative, and degenerative disorders. MATERIALS AND METHODS Sixty-six adult patients with spondylodiscitis (SD, n = 26), tumoral infiltration (TI, n = 20), or Modic type I degeneration (DE, n = 20) findings on spinal magnetic resonance imaging (MRI) included in this retrospective study. Two radiologists scored images for quality on a 4-point scale (image resolution, degree of geometric distortion, lesion selectivity, and diagnostic reliability) and measured signal intensity (SI), apparent diffusion coefficient (ADC), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). DE and SD groups also united to form the benign group. RESULTS In all groups, rs-EPI performed better than ss-EPI in image quality, SNR, and CNR (p < .05). The difference between mean pathological ADC (ADCP) in the two sequences was statistically significant (p < .05). There was no significant difference between the groups in terms of ADCP in rs-EPI (p = .229), unlike ss-EPI (p = .025). Pathological SI (SIP) and CNR in rs-EPI were significantly higher in the malignant group than benign group (p = .002, p < .001). In rs-EPI, no significant difference was found between malignant and benign groups' ADCP (p = .13). CONCLUSION The rs-EPI is a diffusion-weighted imaging (DWI) method with higher image quality that diminishes motion-induced phase errors and increases resolution through phase corrections. However, the distinction of malignant and benign vertebral bone marrow pathologies is unsatisfactory for rs-EPI compared with ss-EPI.
Collapse
Affiliation(s)
- Sevcihan Kesen
- Department of Radiology, Gazi University Faculty of Medicine, Ankara, Turkey
| | - Nil Tokgöz
- Department of Radiology, Gazi University Faculty of Medicine, Ankara, Turkey
| |
Collapse
|
2
|
Hu Y, Hu Q, Liu Z, Huang C, Xia L. Histogram analysis comparison of readout-segmented and single-shot echo-planar imaging for differentiating luminal from non-luminal breast cancer. Sci Rep 2024; 14:12135. [PMID: 38802446 PMCID: PMC11130195 DOI: 10.1038/s41598-024-62514-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2024] [Accepted: 05/17/2024] [Indexed: 05/29/2024] Open
Abstract
To compare diffusion-kurtosis imaging (DKI) and diffusion-weighted imaging (DWI) parameters of single-shot echo-planar imaging (ss-EPI) and readout-segmented echo-planar imaging (rs-EPI) in the differentiation of luminal vs. non-luminal breast cancer using histogram analysis. One hundred and sixty women with 111 luminal and 49 non-luminal breast lesions were enrolled in this study. All patients underwent ss-EPI and rs-EPI sequences on a 3.0T scanner. Histogram metrics were derived from mean kurtosis (MK), mean diffusion (MD) and the apparent diffusion coefficient (ADC) maps of two DWI sequences respectively. Student's t test or Mann-Whitney U test was performed for differentiating luminal subtype from non-luminal subtype. The ROC curves were plotted for evaluating the diagnostic performances of significant histogram metrics in differentiating luminal from non-luminal BC. The histogram metrics MKmean, MK50th, MK75th of luminal BC were significantly higher than those of non-luminal BC for both two DWI sequences (all P<0.05). Histogram metrics from rs-EPI sequence had better diagnostic performance in differentiating luminal from non-Luminal breast cancer compared to those from ss-EPI sequence. MK75th derived from rs-EPI sequence was the most valuable single metric (AUC, 0.891; sensitivity, 78.4%; specificity, 87.8%) for differentiating luminal from non-luminal BC among all the histogram metrics. Histogram metrics of MK derived from rs-EPI yielded better diagnostic performance for distinguishing luminal from non-luminal BC than that from ss-EPI. MK75th was the most valuable metric among all the histogram metrics.
Collapse
Affiliation(s)
- Yiqi Hu
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, Hubei, China
| | - Qilan Hu
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, Hubei, China
| | - Zhiqiang Liu
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, Hubei, China
| | - Cicheng Huang
- Center of Stomatology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, Hubei, China.
| | - Liming Xia
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, Hubei, China.
| |
Collapse
|
3
|
Lemainque T. Editorial for "Effect of Phase Encoding Direction on Image Quality in Single-Shot EPI Diffusion-Weighted Imaging of the Breast". J Magn Reson Imaging 2024. [PMID: 38420670 DOI: 10.1002/jmri.29309] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2023] [Accepted: 12/06/2023] [Indexed: 03/02/2024] Open
Affiliation(s)
- Teresa Lemainque
- Department of Diagnostic and Interventional Radiology, Medical Faculty, RWTH Aachen University, Aachen, Germany
| |
Collapse
|
4
|
Rodríguez-Soto AE, Zou J, Loubrie S, Ebrahimi S, Jordan S, Schlein A, Lim V, Ojeda-Fournier H, Rakow-Penner R. Effect of Phase Encoding Direction on Image Quality in Single-Shot EPI Diffusion-Weighted Imaging of the Breast. J Magn Reson Imaging 2024. [PMID: 38418419 DOI: 10.1002/jmri.29304] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2023] [Revised: 02/05/2024] [Accepted: 02/05/2024] [Indexed: 03/01/2024] Open
Abstract
BACKGROUND In breast diffusion-weighted imaging (DWI), distortion and physiologic artifacts affect clinical interpretation. Image quality can be optimized by addressing the effect of phase encoding (PE) direction on these artifacts. PURPOSE To compare distortion artifacts in breast DWI acquired with different PE directions and polarities, and to discuss their clinical implications. STUDY TYPE Prospective. POPULATION Eleven healthy volunteers (median age: 47 years old; range: 22-74 years old) and a breast phantom. FIELD STRENGTH/SEQUENCE Single-shot echo planar DWI and three-dimensional fast gradient echo sequences at 3 T. ASSESSMENT All DWI data were acquired with left-right, right-left, posterior-anterior, and anterior-posterior PE directions. In phantom data, displacement magnitude was evaluated by comparing the location of landmarks in anatomical and DWI images. Three breast radiologists (5, 17, and 23 years of experience) assessed the presence or absence of physiologic artifacts in volunteers' DWI datasets and indicated their PE-direction preference. STATISTICAL TESTS Analysis of variance with post-hoc tests were used to assess differences in displacement magnitude across DWI datasets and observers. A binomial test and a chi-squared test were used to evaluate if each in vivo DWI dataset had an equal probability (25%) of being preferred by radiologists. Inter-reader agreement was evaluated using Gwet's AC1 agreement coefficient. A P-value <0.05 was considered statistically significant. RESULTS In the phantom study, median displacement was the significantly largest in posterior-anterior data. While the displacement in the anterior-posterior and left-right data were equivalent (P = 0.545). In the in vivo data, there were no physiological artifacts observed in any dataset, regardless of PE direction. In the reader study, there was a significant preference for the posterior-anterior datasets which were selected 94% of the time. There was good agreement between readers (0.936). DATA CONCLUSION This study showed the impact of PE direction on distortion artifacts in breast DWI. In healthy volunteers, the posterior-to-anterior PE direction was preferred by readers. LEVEL OF EVIDENCE 2 TECHNICAL EFFICACY: Stage 1.
Collapse
Affiliation(s)
- Ana E Rodríguez-Soto
- Department of Radiology, University of California San Diego, La Jolla, California, USA
| | - Jingjing Zou
- Herbert Wertheim School of Public Health and Human Longevity Science, University of California San Diego, La Jolla, California, USA
| | - Stephane Loubrie
- Department of Radiology, University of California San Diego, La Jolla, California, USA
| | - Sheida Ebrahimi
- Department of Radiology, University of California San Diego, La Jolla, California, USA
| | - Stephan Jordan
- Department of Radiology, University of California San Diego, La Jolla, California, USA
| | - Alexandra Schlein
- Department of Radiology, University of California San Diego, La Jolla, California, USA
| | - Vivian Lim
- Department of Radiology, University of California San Diego, La Jolla, California, USA
| | - Haydee Ojeda-Fournier
- Department of Radiology, University of California San Diego, La Jolla, California, USA
| | - Rebecca Rakow-Penner
- Department of Radiology, University of California San Diego, La Jolla, California, USA
| |
Collapse
|
5
|
Katscher U, Meineke J, Zhang S, Steinhorst B, Keupp J. Estimation of effective b-value for a diffusion-weighted double-echo steady-state sequence with bipolar gradients. Magn Reson Imaging 2024; 105:10-16. [PMID: 37863374 DOI: 10.1016/j.mri.2023.10.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2023] [Accepted: 10/17/2023] [Indexed: 10/22/2023]
Abstract
Diffusion-weighted double-echo steady-state (dwDESS) MRI with bipolar diffusion gradients is a promising candidate to obtain diffusion weighted images (DWI) free of geometric distortions and with low motion sensitivity. However, a wider clinical application of dwDESS is currently hindered as no method is reported to explicitly calculate the effective b-value of the obtained DWI from the diffusion-gradients applied in the sequence. To this end, a previously described signal model was adapted for dwDESS with bipolar diffusion gradients, which allows to estimate an effective b-value, dubbed b'. Evaluation in phantom examinations was performed on a clinical 1.5 T MR system. Experimental results were compared with theoretical predictions, including the apparent diffusion coefficient (ADC) based on b-values from a standard EPI-DWI sequence and ADC' based on the effective b' from the dwDESS sequence. The adapted signal model was able to describe the experimental results, and the obtained values of ADC' were in line with conventional ADC measurements.
Collapse
Affiliation(s)
- Ulrich Katscher
- Philips Research Europe, Roentgenstrasse 24-26, 22335 Hamburg, Germany.
| | - Jakob Meineke
- Philips Research Europe, Roentgenstrasse 24-26, 22335 Hamburg, Germany
| | - Shuo Zhang
- Philips Healthcare, Roentgenstrasse 24-26, 22335 Hamburg, Germany
| | - Björn Steinhorst
- Philips Research Europe, Roentgenstrasse 24-26, 22335 Hamburg, Germany
| | - Jochen Keupp
- Philips Research Europe, Roentgenstrasse 24-26, 22335 Hamburg, Germany
| |
Collapse
|
6
|
Hu Y, Hu Q, Zhan C, Yin T, Ai T. Intraobserver and Interobserver Reproducibility of Breast Diffusion-Weighted Imaging Quantitative Parameters: Readout-Segmented vs. Single-Shot Echo-Planar Imaging. J Magn Reson Imaging 2023; 58:1725-1736. [PMID: 36807457 DOI: 10.1002/jmri.28655] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2022] [Revised: 02/06/2023] [Accepted: 02/07/2023] [Indexed: 02/23/2023] Open
Abstract
BACKGROUND The recommended technique for breast diffusion-weighted imaging (DWI) acquisitions is not sufficiently standardized in clinical practice. PURPOSE To investigate the intraobserver and interobserver reproducibility of DWI measurements, diffusion-kurtosis imaging (DKI) parameters, and image quality evaluation in breast lesions between single-shot echo-planar imaging (ss-EPI) and readout-segmented echo-planar imaging (rs-EPI). STUDY TYPE Prospective. POPULATION A total of 295 women with 209 malignant and 86 benign breast lesions. FIELD STRENGTH/SEQUENCE A 3-T; fat-saturated T2-weighted MR imaging (T2WI); multi-b-value DWI with both ss-EPI and rs-EPI readouts; T1-weighted dynamic contrast-enhanced MRI (DCE-MRI). ASSESSMENT Mean kurtosis (MK), mean diffusion (MD), and apparent diffusion coefficient (ADC) values were measured for each lesion on ss-EPI and rs-EPI, respectively. Image quality was visually evaluated regarding image sharpness, geometric distortion, lesion conspicuity, visualization of anatomic structures, and overall quality. Quantitative and qualitative analyses were performed twice with a time interval of 2 weeks. STATISTICAL TESTS Intraobserver and interobserver reproducibility were evaluated using intra-class correlation coefficients (ICC), within-subject coefficient of variation (wCV), and Bland-Altman plots. RESULTS MK, MD, and ADC quantitative parameters for breast lesions showed excellent intraobserver and interobserver reproducibility, with ICCs >0.75 and wCV values ranging from 2.51% to 7.08% for both sequences. The wCV values in both intraobserver and interobserver measurements were higher in the ss-EPI sequence (3.63%-7.08%) than that of the rs-EPI sequence (2.51%-3.62%). The wCV values differed in subgroups with different histopathological types of lesions, breast density, lesion morphology, and lesion sizes, respectively. Furthermore, rs-EPI (ICCs, 0.76-0.97; wCV values, 2.41%-6.04%) had better intraobserver and interobserver reproducibility than ss-EPI (ICCs, 0.54-0.90; wCV values, 6.18%-13.69%) with regard to image quality. DATA CONCLUSION Compared to the ss-EPI, the rs-EPI sequence showed higher intraobserver and interobserver reproducibility for quantitative diffusion-related parameters and image quality assessments measured in breast DWI and DKI. EVIDENCE LEVEL 2. TECHNICAL EFFICACY Stage 2.
Collapse
Affiliation(s)
- Yiqi Hu
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China
| | - Qilan Hu
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China
| | - Chenao Zhan
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China
| | - Ting Yin
- MR Collaborations, Siemens Healthineers Ltd., Shanghai, China
| | - Tao Ai
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China
| |
Collapse
|
7
|
Ota R, Kataoka M, Iima M, Honda M, Kishimoto AO, Miyake KK, Yamada Y, Takeuchi Y, Toi M, Nakamoto Y. Evaluation of breast lesions based on modified BI-RADS using high-resolution readout-segmented diffusion-weighted echo-planar imaging and T2/T1-weighted image. Magn Reson Imaging 2023; 98:132-139. [PMID: 36608911 DOI: 10.1016/j.mri.2022.12.024] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2022] [Accepted: 12/31/2022] [Indexed: 01/09/2023]
Abstract
PURPOSE To evaluate the diagnostic performance of a non-contrast magnetic resonance imaging (MRI) protocol combining high-resolution diffusion-weighted images (HR-DWI) using readout-segmented echo planar imaging, T1-weighted imaging (T1WI), and T2-weighted imaging (T2WI), using our modified Breast Imaging-Reporting and Data System (modified BI-RADS). METHODS Two experienced radiologists, blinded to the final pathological diagnosis, categorized a total of 108 breast lesions (61 malignant and 47 benign) acquired with the above protocol using the modified BI-RADS with a diagnostic decision tree. The decision tree included subcategories of category 4, as in mammography (categories 2, 3, 4A, 4B, 4C, and 5). These results were compared with the pathological diagnoses. RESULTS The area under the ROC curve (AUC) was 0.89 (95% confidence interval [CI]: 0.83-0.95) for reader 1, and 0.89 (95% CI: 0.82-0.96) for reader 2. When categories 4C and above were classified as malignant, the sensitivity, specificity, and accuracy were 73.8%, 93.6%, and 82.4%, for reader 1; and 82.0%, 89.4%, and 85.2% for reader 2, respectively. CONCLUSION Our results suggest that using HR-DWI, T1WI/T2WI analyzed with a modified BI-RADS and a decision tree showed promising diagnostic performance in breast lesions, and is worthy of further study.
Collapse
Affiliation(s)
- Rie Ota
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University graduate school of medicine, Kyoto, Japan; Department of Radiology, Tenri Hospital, Nara, Japan
| | - Masako Kataoka
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University graduate school of medicine, Kyoto, Japan.
| | - Mami Iima
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University graduate school of medicine, Kyoto, Japan; Institute for Advancement of Clinical and Translational Science (iACT), Kyoto University Hospital, Kyoto, Japan
| | - Maya Honda
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University graduate school of medicine, Kyoto, Japan; Department of Diagnostic Radiology, Kansai Electric Power Hospital, Osaka, Japan
| | - Ayami Ohno Kishimoto
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University graduate school of medicine, Kyoto, Japan; Department of Radiology, Rakuwakai Otowa Hospital, Kyoto, Japan
| | - Kanae Kawai Miyake
- Department of Advanced Medical Imaging and Research, Kyoto University Graduate School of Medicine, Kyoto, Japan
| | - Yosuke Yamada
- Department of Diagnostic Pathology, Kyoto University Hospital, Kyoto, Japan
| | - Yasuhide Takeuchi
- Department of Diagnostic Pathology, Kyoto University Hospital, Kyoto, Japan
| | - Masakazu Toi
- Department of Breast Surgery, Kyoto University Hospital, Kyoto, Japan
| | - Yuji Nakamoto
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University graduate school of medicine, Kyoto, Japan
| |
Collapse
|
8
|
Yao F, Huang M, Li J, Gao X. Readout-segmented diffusion weighted imaging of the testis at 3.0 T: comparison with single-shot echo-planar imaging. Abdom Radiol (NY) 2023; 48:2131-2138. [PMID: 37029814 DOI: 10.1007/s00261-023-03899-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2023] [Revised: 03/22/2023] [Accepted: 03/23/2023] [Indexed: 04/09/2023]
Abstract
OBJECTIVE The current study aimed to explore the feasibility of readout-segmented echo-planar imaging (RS-EPI) of the testis at 3.0 T, by comparing with single-shot echo-planar imaging (SS-EPI) in qualitative image quality and quantitative apparent diffusion coefficient (ADC) values. METHODS 66 patients undergoing scrotal MRI for various clinical indications were included retrospectively. RS-EPI image quality was rated from 1 (severe distortion or artifact, or nondiagnostic) to 4 (nearly no distortion or artifact, or outstanding). The comparative image quality (RS- vs. SS-EPI) was rated from - 2 (SS-EPI severe or greater conspicuity) to 2 (RS-EPI severe or greater conspicuity). The confidence interval of proportions (CIOP) of comparative image quality and Wilcoxon rank sum test were performed to assess the preferences between RS-EPI and SS-EPI. Paired samples t-test and Bland-Altman analysis were performed to compare the mean ADC values of RS-EPI and SS-EPI. The mean, maximum, and minimum ADC values measured by RS-EPI were compared in normal testicular parenchyma, benign and malignant intratesticular lesions. RESULTS The evaluation of RS-EPI image quality showed RS-EPI with the characteristics of slight geometric distortion and susceptibility artifact, and good lesion conspicuity. The assessment of comparative image quality showed SS-EPI with obvious geometric distortion and susceptibility artifact, and RS-EPI preferred in lesion conspicuity. The CIOP ranged from 97 to 100% among three readers, with preferring to RS-EPI improving image quality (P < 0.001). There was a strong correlation and good agreement between mean ADC values measured by RS-EPI and SS-EPI. The mean, maximum and minimum ADC values by RS-EPI were significantly different in normal testicular parenchyma, benign and malignant intratesticular lesions. CONCLUSION RS-EPI DWI of the testis improved image quality in geometric distortion, susceptibility artifacts, and lesion conspicuity, and provided highly correlated and consistent mean ADC values when compared to SS-EPI DWI, indicating the feasibility of RS-EPI DWI of testes.
Collapse
Affiliation(s)
- Feifei Yao
- Department of MRI, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, 450052, China.
| | - Mengyue Huang
- Department of MRI, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, 450052, China
| | - Juan Li
- Department of MRI, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, 450052, China
| | - Xuemei Gao
- Department of MRI, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, 450052, China
| |
Collapse
|
9
|
Yoshimura Y, Sugimoto K, Miyahara K. [Examination of Reacquisition Mode in Readout-segmented EPI during the Body Motion]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2023. [PMID: 36908164 DOI: 10.6009/jjrt.2023-1355] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/11/2023]
Abstract
Readout-segmented echo planar imaging has a reacquisition mode in case of body motion. The phantom was moved and imaged to characterize the reacquisition mode. The counts, angle, and terms of continuous body motion and the terms and counts of intermittent body motion were changed. Then, we investigated the effect on the image quality and the improvement effect of the reacquisition mode. We compared the signal intensity of each pixel in images without body motion and images with and without the reacquisition mode using Spearman's correlation coefficient. The correlation coefficient decreased with increasing counts of body motion. There was no difference by angle. The correlation coefficient was high for body motion immediately after the start of imaging and decreased thereafter. The correlation coefficient was high when the counts of body motion were decreased and even when the terms of body motion increased. In all cases, the correlation coefficient was improved by the reacquisition mode.
Collapse
Affiliation(s)
- Yuuki Yoshimura
- Department of Radiological Technology, Okayama Saiseikai General Hospital
| | - Kohei Sugimoto
- Divisions of Imaging Technology, Okayama Diagnostic Imaging Center.,Graduate School of Interdisciplinary Science and Engineering in Health Systems, Okayama University
| | - Kanae Miyahara
- Department of Radiological Technology, Okayama Saiseikai General Hospital
| |
Collapse
|
10
|
Diffusion-Weighted Imaging as a Quantitative Imaging Biomarker for Predicting Proliferation Rate in Hepatocellular Carcinoma: Developing a Radiomics Nomogram. J Comput Assist Tomogr 2023:00004728-990000000-00132. [PMID: 36877762 DOI: 10.1097/rct.0000000000001448] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/07/2023]
Abstract
PURPOSE This study aimed to explore the predictive performance of diffusion-weighted imaging with apparent diffusion coefficient map in predicting the proliferation rate of hepatocellular carcinoma and to develop a radiomics-based nomogram. METHODS This was a single-center retrospective study. A total of 110 patients were enrolled. The sample included 38 patients with low Ki67 expression (Ki67 ≤10%) and 72 with high Ki67 expression (Ki67 >10%) as demonstrated by surgical pathology. Patients were randomly divided into either a training (n = 77) or validation (n = 33) cohort. Diffusion-weighted imaging with apparent diffusion coefficient maps was used to extract radiomic features and the signal intensity values of tumor (SItumor), normal liver (SIliver), and background noise (SIbackground) from all samples. Subsequently, the clinical model, radiomic model, and fusion model (with clinical data and radiomic signature) were developed and validated. RESULTS The area under the curve (AUC) of the clinical model for predicting the Ki67 expression including serum α-fetoprotein level (P = 0.010), age (P = 0.015), and signal noise ratio (P = 0.026) was 0.799 and 0.715 in training and validation cohorts, respectively. The AUC of the radiomic model constructed by 9 selected radiomic features was 0.833 and 0.772 in training and validation cohorts, respectively. The AUC of the fusion model containing serum α-fetoprotein level (P = 0.011), age (P = 0.019), and rad score (P < 0.001) was 0.901 and 0.781 in training and validation cohorts, respectively. CONCLUSIONS Diffusion-weighted imaging as a quantitative imaging biomarker can predict Ki67 expression level in hepatocellular carcinoma across various models.
Collapse
|
11
|
Effectiveness of simultaneous multislice accelerated readout-segmented echo planar imaging for the assessment of rectal cancer. Eur J Radiol 2023; 159:110649. [PMID: 36563564 DOI: 10.1016/j.ejrad.2022.110649] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2022] [Revised: 11/17/2022] [Accepted: 12/10/2022] [Indexed: 12/15/2022]
Abstract
PURPOSE To investigate the effectiveness of simultaneous multislice (SMS) accelerated readout-segmented echo planar imaging (RESOLVE) DWI for assessing rectal cancer in the clinic. METHOD Sixty consecutive histologically proven rectal cancer patients were enrolled. They all received MRI examinations, including both SMS-RESOLVE and RESOLVE sequences. Two readers visually assessed the overall image quality, distinction of anatomical structures, lesion conspicuity, and artifacts of two sequences by using a qualitative 4-point Likert scale. The quantitative ADC value, lesion contrast, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and temporal SNR (tSNR) were independently calculated in rectal cancer on the largest slice of the tumor. RESULTS The scan time was shortened from 3 min and 50 s to 1 min and 47 s. The interobserver agreement of visual and quantitative assessments between the two readers was good overall. There were no differences in overall image quality, lesion conspicuity or artifact scores between the two sequences in both readers (all p > 0.05). The lesion contrast (p = 0.013) was significantly higher in SMS-RESOLVE, and the CNR was similar in the two DWIs. The scores of distinctions of anatomical structures in SMS-RESOLVE were lower (all p < 0.05) in both readers. The SNR of SMS-RESOLVE was lower than that of RESOLVE (p = 0.004), and the tSNR of SMS-RESOLVE was significantly higher (p < 0.001). The ADC value of the tumor was lower in SMS-RESOLVE (p = 0.001), but the ADC values of the normal rectal wall showed no difference between the two DWIs. CONCLUSION SMS-RESOLVE allowed a substantial reduction in acquisition time while maintaining overall image quality and lesion conspicuity in rectal cancer. It also had a higher contrast of the lesion and a higher temporal SNR.
Collapse
|
12
|
Ruan D, Sun L. Diagnostic Performance of PET/MRI in Breast Cancer: A Systematic Review and Bayesian Bivariate Meta-analysis. Clin Breast Cancer 2023; 23:108-124. [PMID: 36549970 DOI: 10.1016/j.clbc.2022.11.010] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2022] [Revised: 11/07/2022] [Accepted: 11/26/2022] [Indexed: 12/04/2022]
Abstract
INTRODUCTION By performing a systematic review and meta-analysis, the diagnostic value of 18F-FDG PET/MRI in breast lesions, lymph nodes, and distant metastases was assessed, and the merits and demerits of PET/MRI in the application of breast cancer were comprehensively reviewed. METHODS Breast cancer-related studies using 18F-FDG PET/MRI as a diagnostic tool published before September 12, 2022 were included. The pooled sensitivity, specificity, log diagnostic odds ratio (LDOR), and area under the curve (AUC) were calculated using Bayesian bivariate meta-analysis in a lesion-based and patient-based manner. RESULTS We ultimately included 24 studies (including 1723 patients). Whether on a lesion-based or patient-based analysis, PET/MRI showed superior overall pooled sensitivity (0.95 [95% CI: 0.92-0.98] & 0.93 [95% CI: 0.88-0.98]), specificity (0.94 [95% CI: 0.90-0.97] & 0.94 [95% CI: 0.92-0.97]), LDOR (5.79 [95% CI: 4.95-6.86] & 5.64 [95% CI: 4.58-7.03]) and AUC (0.98 [95% CI: 0.94-0.99] & 0.98[95% CI: 0.92-0.99]) for diagnostic applications in breast cancer. In the specific subgroup analysis, PET/MRI had high pooled sensitivity and specificity for the diagnosis of breast lesions and distant metastatic lesions and was especially excellent for bone lesions. PET/MRI performed poorly for diagnosing axillary lymph nodes but was better than for lymph nodes at other sites (pooled sensitivity, specificity, LDOR, AUC: 0.86 vs. 0.58, 0.90 vs. 0.82, 4.09 vs. 1.98, 0.89 vs. 0.84). CONCLUSION 18F-FDG PET/MRI performed excellently in diagnosing breast lesions and distant metastases. It can be applied to the initial diagnosis of suspicious breast lesions, accurate staging of breast cancer patients, and accurate restaging of patients with suspected recurrence.
Collapse
Affiliation(s)
- Dan Ruan
- Department of Nuclear Medicine, Zhongshan Hospital (Xiamen), Fudan University, Xiamen, China
| | - Long Sun
- Department of Nuclear Medicine and Minnan PET Center, Xiamen Cancer Hospital, The First Affiliated Hospital of Xiamen University, Xiamen, China.
| |
Collapse
|
13
|
Turbo Gradient and Spin-Echo BLADE-DWI for Extraocular Muscles in Thyroid-Associated Ophthalmopathy. J Clin Med 2023; 12:jcm12010344. [PMID: 36615144 PMCID: PMC9821770 DOI: 10.3390/jcm12010344] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2022] [Revised: 12/28/2022] [Accepted: 12/28/2022] [Indexed: 01/03/2023] Open
Abstract
Purpose: To investigate feasibility and diagnostic performance of turbo gradient and spin-echo BLADE (proprietary name for Periodically Rotated Overlapping ParallEL Lines with Enhanced Reconstruction [PROPELLER] in Siemens MR systems)-diffusion weighted imaging (TGSE-BLADE-DWI) for depicting extraocular muscle (EOM) involvement and activity in thyroid-associated ophthalmopathy (TAO), and to compare TGSE-BLADE-DWI with readout-segmented echo-planar imaging (RESOLVE). Materials and methods: Thirty-five patients with identified TAO underwent the two DWI scans. Two radiologists visually scored the image quality of the two DWIs with respect to the susceptibility artifacts and geometric distortions on a three-point scale. The maximum size (Sizemax) of EOMs and corresponding ADCs (cADCs) of each patient were compared between the active and inactive phases. The clinical activity score (CAS) was used as a reference to assess the diagnostic performance of EOM ADCs for grading TAO activity. ROC analysis, Pearson correlation, and Wilcoxon signed-rank test were used for statistical analyses. Results: For scores of EOMs, the image quality of TGSE-BLADE-DWI was significantly higher than that of RESOLVE. There were no statistically significant differences between the AUCs of the two DWIs, Sizemax, or cADCs between the active and inactive phases. TGSE-BLADE-DWI ADCs were significantly higher than the RESOLVE ADCs in the right superior rectus, right lateral rectus, left superior rectus, and left inferior rectus. There were no statistically significant correlations between the cADC or Sizemax, and CAS. The highest AUC was 0.697 for RESOLVE and 0.657 for TGSE-BLADE-DWI. The best performing ADC threshold was 1.85 × 10-3 mm2/s with 85.7% sensitivity, 58.8% specificity and 66.67% accuracy for RESOLVE and 1.99 × 10-3 mm2/s with 79.0% sensitivity, and 55.6% specificity and 65.27% accuracy for TGSE-BLADE-DWI. Conclusion: Compared to RESOLVE, TGSE-BLADE-DWI provided improved image quality with fewer susceptibility artifacts and geometric distortions for EOM visualization and showed an equivalent performance in detecting active TAO.
Collapse
|
14
|
Okuchi S, Fushimi Y, Yoshida K, Nakajima S, Sakata A, Hinoda T, Otani S, Sagawa H, Zhou K, Yamao Y, Okawa M, Nakamoto Y. Comparison of TGSE-BLADE DWI, RESOLVE DWI, and SS-EPI DWI in healthy volunteers and patients after cerebral aneurysm clipping. Sci Rep 2022; 12:17689. [PMID: 36271294 PMCID: PMC9586944 DOI: 10.1038/s41598-022-22760-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2022] [Accepted: 10/19/2022] [Indexed: 01/18/2023] Open
Abstract
Diffusion-weighted magnetic resonance imaging is prone to have susceptibility artifacts in an inhomogeneous magnetic field. We compared distortion and artifacts among three diffusion acquisition techniques (single-shot echo-planar imaging [SS-EPI DWI], readout-segmented EPI [RESOLVE DWI], and 2D turbo gradient- and spin-echo diffusion-weighted imaging with non-Cartesian BLADE trajectory [TGSE-BLADE DWI]) in healthy volunteers and in patients with a cerebral aneurysm clip. Seventeen healthy volunteers and 20 patients who had undergone surgical cerebral aneurysm clipping were prospectively enrolled. SS-EPI DWI, RESOLVE DWI, and TGSE-BLADE DWI of the brain were performed using 3 T scanners. Distortion was the least in TGSE-BLADE DWI, and lower in RESOLVE DWI than SS-EPI DWI near air-bone interfaces in healthy volunteers (P < 0.001). Length of clip-induced artifact and distortion near the metal clip were the least in TGSE-BLADE DWI, and lower in RESOLVE DWI than SS-EPI DWI (P < 0.01). Image quality scores for geometric distortion, susceptibility artifacts, and overall image quality in both healthy volunteers and patients were the best in TGSE-BLADE DWI, and better in RESOLVE DWI than SS-EPI DWI (P < 0.001). Among the three DWI sequences, image quality was the best in TGSE-BLADE DWI in terms of distortion and artifacts, in both healthy volunteers and patients with an aneurysm clip.
Collapse
Affiliation(s)
- Sachi Okuchi
- grid.258799.80000 0004 0372 2033Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto University, 54 Shogoin Kawaharacho, Sakyoku, Kyoto, 6068507 Japan
| | - Yasutaka Fushimi
- grid.258799.80000 0004 0372 2033Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto University, 54 Shogoin Kawaharacho, Sakyoku, Kyoto, 6068507 Japan
| | - Kazumichi Yoshida
- grid.258799.80000 0004 0372 2033Department of Neurosurgery, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Satoshi Nakajima
- grid.258799.80000 0004 0372 2033Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto University, 54 Shogoin Kawaharacho, Sakyoku, Kyoto, 6068507 Japan
| | - Akihiko Sakata
- grid.258799.80000 0004 0372 2033Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto University, 54 Shogoin Kawaharacho, Sakyoku, Kyoto, 6068507 Japan
| | - Takuya Hinoda
- grid.258799.80000 0004 0372 2033Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto University, 54 Shogoin Kawaharacho, Sakyoku, Kyoto, 6068507 Japan
| | - Sayo Otani
- grid.258799.80000 0004 0372 2033Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto University, 54 Shogoin Kawaharacho, Sakyoku, Kyoto, 6068507 Japan
| | - Hajime Sagawa
- grid.411217.00000 0004 0531 2775Division of Clinical Radiology Service, Kyoto University Hospital, Kyoto, Japan
| | - Kun Zhou
- Siemens Shenzhen Magnetic Resonance Ltd, Shenzhen, China
| | - Yukihiro Yamao
- grid.258799.80000 0004 0372 2033Department of Neurosurgery, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Masakazu Okawa
- grid.258799.80000 0004 0372 2033Department of Neurosurgery, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Yuji Nakamoto
- grid.258799.80000 0004 0372 2033Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto University, 54 Shogoin Kawaharacho, Sakyoku, Kyoto, 6068507 Japan
| |
Collapse
|
15
|
Whole-tumor apparent diffusion coefficient (ADC) analyses of breast lesions based on simultaneous multi-slice readout-segmented echo-planar diffusion-weighted imaging. Magn Reson Imaging 2022; 94:119-126. [PMID: 36191856 DOI: 10.1016/j.mri.2022.09.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2021] [Revised: 01/28/2022] [Accepted: 09/27/2022] [Indexed: 11/24/2022]
Abstract
OBJECTIVE We aimed to evaluate the effectiveness of simultaneous multi-slice readout-segmented echo-planar diffusion-weighted imaging (SMS rs-EPI DWI), compared with readout-segmented echo-planar diffusion-weighted imaging (NOSMS rs-EPI DWI), in discriminating between benign and malignant breast lesions. MATERIALS AND METHODS This retrospective study evaluated breast lesions from 185 consecutive patients who had undergone preoperative breast MRI. The NOSMS rs-EPI DWI and the prototype SMS rs-EPI DWI sequences were performed on a 1.5-T MR scanner. Two independent radiologists evaluated the image quality of the two sequences using a 5-point scale (1 = poor, 5 = excellent) and then assessed the scores through visual grading characteristics analysis (VGC). The values of signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and whole-tumor-based histogram parameter (ADCmedian) were compared between the two sequences using the Wilcoxon test. Then ROC curves were used for statistical analysis. RESULTS The visual assessment showed that the SMS rs-EPI yielded superior overall image quality and lesion delineation than the NOSMS rs-EPI (AUCVGC = 0.980 and 0.984, respectively; all Ps < 0.001). There were no significant differences in relevant artifacts between the two sequences (AUCVGC = 0.531, P = 0.462). The SNR values for SMS rs-EPI DWI were significantly lower than for NOSMS rs-EPI DWI (P = 0.019) while there was no significant difference in CNR values between the two sequences (P = 0.955). In addition, evaluation of the diagnostic performance demonstrated that the difference in ADCmedian values for both DWI sequences between the malignant and benign lesions was statistically significant (P < 0.001). In contrast, the AUC for ADCmedian was higher with SMS rs-EPI than NOSMS rs-EPI (0.879 for SMS vs. 0.839 for NOSMS, P = 0.025). CONCLUSION The SMS technique could further improve the image quality and the diagnostic performance of rs-EPI DWI in a comparable time.
Collapse
|
16
|
Zhong M, Yang Z, Chen X, Huang R, Wang M, Fan W, Dai Z, Chen X. Readout-Segmented Echo-Planar Diffusion-Weighted MR Imaging Improves the Differentiation of Breast Cancer Receptor Statuses Compared With Conventional Diffusion-Weighted Imaging. J Magn Reson Imaging 2022; 56:691-699. [PMID: 35038210 PMCID: PMC9542110 DOI: 10.1002/jmri.28065] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2021] [Revised: 01/04/2022] [Accepted: 01/05/2022] [Indexed: 02/05/2023] Open
Abstract
BACKGROUND Readout-segmented echo-planar diffusion-weighted imaging (RS-EPI) can improve image quality and signal-to-noise ratio, the resulting apparent diffusion coefficient (ADC) value acts as a more sensitive biomarker to characterize tumors. However, data regarding the differentiation of breast cancer (BC) receptor statuses using RS-EPI are limited. PURPOSE To determine whether RS-EPI improves the differentiation of receptor statuses compared with conventional single-shot (SS) EPI in breast MRI. STUDY TYPE Retrospective. POPULATION A total of 151 BC women with the mean age of 50.6 years. FIELD STRENGTH/SEQUENCE A 3 T/ RS-EPI and SS-EPI. ASSESSMENT The ADCs of the lesion and normal background tissue from the two sequences were collected by two radiologists with 15 years of experience working of breast MRI (M.H.Z. and X.F.C.), and a normalized ADC was calculated by dividing the mean ADC value of the lesion by the mean ADC value of the normal background tissue. STATISTICAL TESTS Agreement between the ADC measurements from the two sequences was assessed using the Pearson correlation coefficient and Bland-Altman plots. One-way analysis of variance, Kruskal-Wallis test, and median difference were used to compare the ADC measurements for all lesions and different receptor statuses. A P value less than 0.05 indicated a significant result. RESULTS The ADC measurements of all lesions and normal background tissues were significantly higher on RS-EPI than on SS-EPI (1.82 ± 0.33 vs. 1.55 ± 0.30 and 0.83 ± 0.11 vs. 0.79 ± 0.10). The normalized ADC was lower on RS-EPI than on SS-EPI (0.47 ± 0.11 vs. 0.53 ± 0.12, a median difference of -0.04 [95% CI: -0.256 to 0.111]). For both diffusion methods, only the ADC measurement of RS-EPI was higher for human epidermal growth factor receptor-2 (HER-2)-positive tumors than for HER-2-negative tumors (0.87 ± 0.10 vs. 0.81 ± 0.11), and this measurement was associated with HER-2 positive status (adjusted odds ratio [OR] = 654.4); however, similar results were not observed for the ADC measurement of SS-EPI (0.80 ± 0.10 vs. 0.78 ± 0.11 with P = 0.199 and adjusted OR = 0.21 with P = 0.464, respectively). DATA CONCLUSION RS-EPI can improve the distinction between HER-2-positive and HER-2-negative breast cancer, complementing the clinical application of diffusion imaging. EVIDENCE LEVEL 3 TECHNICAL EFFICACY: Stage 1.
Collapse
Affiliation(s)
- Minghao Zhong
- Department of Radiology, Meizhou People's HospitalMeizhou514031China
| | - Zhiqi Yang
- Department of Radiology, Meizhou People's Hospital, Meizhou, 514031 China
- Guangdong Provincial Key Laboratory of Precision Medicine and Clinical Translational Research of Hakka Population, Meizhou, 514031 China
| | - Xiaofeng Chen
- Department of Radiology, Meizhou People's HospitalMeizhou514031China
- Guangdong Provincial Key Laboratory of Precision Medicine and Clinical Translational Research of Hakka PopulationMeizhou514031China
| | - Ruibin Huang
- Department of RadiologyFirst Affiliated Hospital of Shantou University Medical CollegeShantou515000China
| | - Mengzhu Wang
- MR Scientific Marketing, Siemens HealthineersGuangzhou510620China
| | - Weixiong Fan
- Department of Radiology, Meizhou People's HospitalMeizhou514031China
| | - Zhuozhi Dai
- Department of Radiology, Shantou Central Hospital, Shantou, Guangdong, 515041 China
| | - Xiangguang Chen
- Guangdong Provincial Key Laboratory of Precision Medicine and Clinical Translational Research of Hakka Population, Meizhou, 514031 China
- Department of Radiology, Meizhou People's Hospital, Meizhou, 514031 China
| |
Collapse
|
17
|
Sun K, Zhu H, Xia B, Li X, Chai W, Fu C, Thomas B, Liu W, Grimm R, Elisabeth W, Yan F. Image quality and whole-lesion histogram and texture analysis of diffusion-weighted imaging of breast MRI based on advanced ZOOMit and simultaneous multislice readout-segmented echo-planar imaging. Front Oncol 2022; 12:913072. [PMID: 36033543 PMCID: PMC9411810 DOI: 10.3389/fonc.2022.913072] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2022] [Accepted: 07/13/2022] [Indexed: 11/24/2022] Open
Abstract
Objectives To investigate the image quality and diagnostic capability a of whole-lesion histogram and texture analysis of advanced ZOOMit (A-ZOOMit) and simultaneous multislice readout-segmented echo-planar imaging (SMS-RS-EPI) to differentiate benign from malignant breast lesions. Study design From February 2020 to October 2020, diffusion-weighted imaging (DWI) using SMS-RS-EPI and A-ZOOMit were performed on 167 patients. Three breast radiologists independently ranked the image datasets. The inter-/intracorrelation coefficients (ICCs) of mean image quality scores and lesion conspicuity scores were calculated between these three readers. Histogram and texture features were extracted from the apparent diffusion coefficient (ADC) maps, respectively, based on a WL analysis. Student’s t-tests, one-way ANOVAs, Mann–Whitney U tests, and receiver operating characteristic curves were used for statistical analysis. Results The overall image quality scores and lesion conspicuity scores for A-ZOOMit and SMS-RS-EPI showed statistically significant differences (4.92 ± 0.27 vs. 3.92 ± 0.42 and 4.93 ± 0.29 vs. 3.87 ± 0.47, p < 0.0001). The ICCs for the image quality and lesion conspicuity scores had good agreements among the three readers (all ICCs >0.75). To differentiate benign and malignant breast lesions, the entropy of ADCA-Zoomit had the highest area (0.78) under the ROC curve. Conclusions A-ZOOMit achieved higher image quality and lesion conspicuity than SMS-RS-EPI. Entropy based on A-ZOOMit is recommended for differentiating benign from malignant breast lesions.
Collapse
Affiliation(s)
- Kun Sun
- Department of Radiology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China
- *Correspondence: Kun Sun,
| | - Hong Zhu
- Department of Radiology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China
| | - Bingqing Xia
- Department of Radiology, International Peace Maternity and Child Health Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China
| | - Xinyue Li
- Department of Radiology, Ruijin Hospital Luwan Branch, Shanghai Jiaotong University School of Medicine, Shanghai, China
| | - Weimin Chai
- Department of Radiology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China
| | - Caixia Fu
- MR Application Development, Siemens Shenzhen Magnetic Resonance Ltd., Shenzhen, China
| | - Benkert Thomas
- MR Application Predevelopment, Siemens Healthcare, Erlangen, Germany
| | - Wei Liu
- MR Application Development, Siemens Shenzhen Magnetic Resonance Ltd., Shenzhen, China
| | - Robert Grimm
- MR Application Predevelopment, Siemens Healthcare, Erlangen, Germany
| | - Weiland Elisabeth
- MR Application Predevelopment, Siemens Healthcare, Erlangen, Germany
| | - Fuhua Yan
- Department of Radiology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China
| |
Collapse
|
18
|
Hosseiny M, Sung KH, Felker E, Suvannarerg V, Tubtawee T, Shafa A, Arora KR, Ching J, Gulati A, Azadikhah A, Zhong X, Sayre J, Lu D, Raman SS. Read-out Segmented Echo Planar Imaging with Two-Dimensional Navigator Correction (RESOLVE): An Alternative Sequence to Improve Image Quality on Diffusion-Weighted Imaging of Prostate. Br J Radiol 2022; 95:20211165. [PMID: 35671135 PMCID: PMC10162059 DOI: 10.1259/bjr.20211165] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2021] [Revised: 04/28/2022] [Accepted: 05/23/2022] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVE We aimed to investigate if the use of read-out segmented echoplanar imaging with additional two-dimensional navigator correction (Readout Segmentation of Long Variable Echo, RESOLVE) for acquiring prostate diffusion-weighted imaging (DWI) improves image quality, compared to single-shot echoplanar imaging (ss-EPI). METHODS This single-center prospective study cohort included 162 males with suspected prostate cancer, who underwent 3 Tesla multiparametric MRI (3T-mpMRI). Two abdominal radiologists, blinded to the clinical information, separately reviewed each 3T-mpMRI study to rank geometrical distortion, degree of rectal distention, lesion conspicuity, and anatomic details delineation first on ss-EPI-DWI and later on RESOLVE-DWI using 5-point scales (1 = excellent, 5 = poor). The average of the ranking scores given by two readers was generated and used as the final score. RESULTS There was good-to-excellent interreader agreement for scoring image quality parameters on both ss-EPI and RESOLVE. Geometrical distortion scores > 3 was seen in 12.3% (20/162) of ss-EPI images, with all having geometrical distortion score <3 on RESOLVE (p < .001). The mean image distortion score was significantly less on RESOLVE than ss-EPI (1.16 vs 1.61, p < .01 regardless of rectal gas, p< .05 when stratified by the degree of rectal distention ). RESOLVE was superior to ss-EPI for lesion conspicuity (mean 1.35 vs 1.53, p< .002) and anatomic delineation (2.60 vs 2.68, p< .001) of prostate on DWI. CONCLUSION Compared to conventional ss-EPI, the use of RESOLVE for acquisition of prostate DWI resulted in significantly enhanced image quality and reduced geometrical distortion. ADVANCES IN KNOWLEDGE RESOLVE could be an alternative or replacement of ss-EPI for acquiring prostate DWI with significantly less geometrical distortion and significantly improved lesion conspicuity and anatomic delineation.
Collapse
Affiliation(s)
- Melina Hosseiny
- Department of Radiology, Ronald Reagan-UCLA Medical Center, David Geffen School of Medicine at UCLA, Los Angeles, California, United States
| | - Kyung Hyun Sung
- Department of Radiology, Ronald Reagan-UCLA Medical Center, David Geffen School of Medicine at UCLA, Los Angeles, California, United States
| | - Ely Felker
- Department of Radiology, Ronald Reagan-UCLA Medical Center, David Geffen School of Medicine at UCLA, Los Angeles, California, United States
| | - Voraparee Suvannarerg
- Department of Radiology, Ronald Reagan-UCLA Medical Center, David Geffen School of Medicine at UCLA, Los Angeles, California, United States
| | | | - Ariel Shafa
- Department of Radiology, Ronald Reagan-UCLA Medical Center, David Geffen School of Medicine at UCLA, Los Angeles, California, United States
| | - Krishan R. Arora
- Department of Radiology, Ronald Reagan-UCLA Medical Center, David Geffen School of Medicine at UCLA, Los Angeles, California, United States
| | - Justin Ching
- Department of Radiology, Ronald Reagan-UCLA Medical Center, David Geffen School of Medicine at UCLA, Los Angeles, California, United States
| | - Anjalie Gulati
- Department of Radiology, Ronald Reagan-UCLA Medical Center, David Geffen School of Medicine at UCLA, Los Angeles, California, United States
| | - Afshin Azadikhah
- Department of Radiology, Ronald Reagan-UCLA Medical Center, David Geffen School of Medicine at UCLA, Los Angeles, California, United States
| | - Xiaodong Zhong
- Siemens Healthcare, MR R&D Collaborations, Lilburn, Georgia, United States
| | - James Sayre
- Department of Bioinformatics, David Geffen School of Medicine at UCLA, Los Angeles, California, United States
| | - David Lu
- Department of Radiology, Ronald Reagan-UCLA Medical Center, David Geffen School of Medicine at UCLA, Los Angeles, California, United States
| | | |
Collapse
|
19
|
Tang C, Qin Y, Hu Q, Ai T. Diagnostic value of multi-model high-resolution diffusion-weighted MR imaging in breast lesions: Based on simultaneous multi-slice readout-segmented echo-planar imaging. Eur J Radiol 2022; 154:110439. [PMID: 35863281 DOI: 10.1016/j.ejrad.2022.110439] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2022] [Revised: 06/30/2022] [Accepted: 07/05/2022] [Indexed: 11/19/2022]
Abstract
PURPOSE To investigate the diagnostic value of multi-model high-resolution diffusion-weighted MR imaging (DWI) in breast lesions, with a comparison of simultaneous multi-slice readout-segmented echo-planar imaging (SMS rs-EPI) and single-shot EPI (ss-EPI). MATERIALS AND METHODS This retrospective study was approved by the institutional ethics committee and included 120 patients with 122 breast lesions (25 benign and 97 malignant). All patients underwent breast DWI with multi-b values (0, 50, 100, 200, 400, 800, 1200, and 2000 s/mm2) based on both SMS rs-EPI and ss-EPI on a 3.0 T MR scanner. Quantitative DWI-derived parameters including ADC, MK, MD, D, D*, and f were calculated based on mono-exponential (Mono), intravoxel incoherent motion (IVIM), diffusion kurtosis (DKI) models. Meanwhile, both DWI sequences were qualitatively evaluated with respect to overall image quality, lesion conspicuity, image artifact, geometric distortion, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and lesion contrast. The differences in DW-derived parameters, image quality, and diagnostic performance were statistically compared between SMS rs-EPI and ss-EPI groups. RESULTS The SMS rs-EPI produced higher Contrast, CNR and lower SNR than ss-EPI (p < 0.01). The image quality of SMS rs-EPI was superior to ss-EPI either in subjective or objective evaluation. There was no significant difference between the SMS rs-EPI and ss-EPI for either MD or the D* (p > 0.05). However, the MK and f between the two sequences showed significant differences (p < 0.05). Spearman's correlation coefficient displayed good linear correlation for MK values (r = 0.73, 95% CI 0.617-0.857), MD values (r = 0.88, 95% CI 0.814-0.926), ADC values (r = 0.93, 95% CI 0.869-0.948) and D values (r = 0.93, 95% CI 0.856-0.948) between SMS rs-EPI and ss-EPI. Spearman's correlation coefficient for f values (r = 0.25, 95% CI 0.226-0.559) and D* values (r = 0.22, 95% CI 0.025-0.348) were fair and no correlation between the two sequences. MK values have the highest diagnostic value in differentiating benign and malignant breast lesions. CONCLUSIONS High-resolution multi-model DWI based on SMS rs-EPI technique can provide superior image quality and lesion characterization, with comparable diagnostic performance as compared with ss-EPI DWI in differentiating benign and malignant breast lesions. Of different DWI-derived parameters, MK values showed the best diagnostic performance.
Collapse
Affiliation(s)
- Caili Tang
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China
| | - Yanjin Qin
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China
| | - Qilan Hu
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China
| | - Tao Ai
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China.
| |
Collapse
|
20
|
Mendez AM, Fang LK, Meriwether CH, Batasin SJ, Loubrie S, Rodríguez-Soto AE, Rakow-Penner RA. Diffusion Breast MRI: Current Standard and Emerging Techniques. Front Oncol 2022; 12:844790. [PMID: 35880168 PMCID: PMC9307963 DOI: 10.3389/fonc.2022.844790] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2021] [Accepted: 05/11/2022] [Indexed: 11/13/2022] Open
Abstract
The role of diffusion weighted imaging (DWI) as a biomarker has been the subject of active investigation in the field of breast radiology. By quantifying the random motion of water within a voxel of tissue, DWI provides indirect metrics that reveal cellularity and architectural features. Studies show that data obtained from DWI may provide information related to the characterization, prognosis, and treatment response of breast cancer. The incorporation of DWI in breast imaging demonstrates its potential to serve as a non-invasive tool to help guide diagnosis and treatment. In this review, current technical literature of diffusion-weighted breast imaging will be discussed, in addition to clinical applications, advanced techniques, and emerging use in the field of radiomics.
Collapse
Affiliation(s)
- Ashley M. Mendez
- Department of Radiology, University of California San Diego, La Jolla, CA, United States
| | - Lauren K. Fang
- Department of Radiology, University of California San Diego, La Jolla, CA, United States
| | - Claire H. Meriwether
- Department of Radiology, University of California San Diego, La Jolla, CA, United States
| | - Summer J. Batasin
- Department of Radiology, University of California San Diego, La Jolla, CA, United States
| | - Stéphane Loubrie
- Department of Radiology, University of California San Diego, La Jolla, CA, United States
| | - Ana E. Rodríguez-Soto
- Department of Radiology, University of California San Diego, La Jolla, CA, United States
| | - Rebecca A. Rakow-Penner
- Department of Radiology, University of California San Diego, La Jolla, CA, United States,Department of Bioengineering, University of California San Diego, La Jolla, CA, United States,*Correspondence: Rebecca A. Rakow-Penner,
| |
Collapse
|
21
|
Chen Y, Pan Z, Meng F, Xu Q, Huang L, Pu X, Yu X, Wu Y, Lyu H, Lin X. Assessment of Rat Sciatic Nerve Using Diffusion-Tensor Imaging With Readout-Segmented Echo Planar Imaging. Front Neurosci 2022; 16:938674. [PMID: 35812234 PMCID: PMC9260505 DOI: 10.3389/fnins.2022.938674] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2022] [Accepted: 05/30/2022] [Indexed: 11/13/2022] Open
Abstract
ObjectivesThis study aimed to compare readout-segmented-3, readout-segmented-5, and readout-segmented-7 echo-planar imaging (RS3-EPI, RS5-EPI, and RS7-EPI) of DTI in the assessment of rat sciatic nerve at 3T MR.MethodsEight male adult healthy Sprague-Dawley rats were scanned at 3T MR with RS-3 EPI, RS5-EPI, and RS-7 EPI DTI. The image quality of RS-3 EPI, RS-5 EPI, and RS-7 EPI in terms of the nerve morphology, distortions of the nearby femur, muscles, and homogeneity of neuromuscular were evaluated by two experienced radiologists. The correlations between the histopathological and DTI parameters, including fractional anisotropy (FA) and radial diffusivity (RD), were calculated, respectively, and compared in RS-3, RS-5, and RS-7 EPI. The image quality scores for RS-3 EPI, RS-5 EPI, and RS-7 EPI were compared using the Wilcoxon rank-sum test. The correlation between DTI and histopathological parameters was calculated using the Pearson correlation coefficient.ResultsRS-5 EPI yielded the best SNR-values corrected for the acquisition time compared to RS3-EPI and RS7-EPI. The image quality scores of RS-5 EPI were superior to those of RS-3 and RS-7 EPI (P = 0.01–0.014) and lower artifacts of the ventral/dorsal margin and femur (P = 0.008–0.016) were shown. DTT analysis yielded a significantly higher number of tracts for RS5-EPI compared to RS3-EPI (P = 0.007) but no significant difference with RS7-EPI (P = 0.071). For the three sequences, FA and RD were well-correlated with the myelin-related histopathological parameters (|r| 0.709–0.965, P = 0.001–0.049). The overall correlation coefficients of FA and RD obtained from RS-5 EPI were numerically higher than that with both RS3-EPI and RS7-EPI.ConclusionFor the rat sciatic nerve DTI imaging, RS-5 EPI offered the best image quality and SNR-values corrected for the acquisition time. The FA and RD derived from the RS-5 EPI were the most sensitive quantitative biomarkers to detect rat sciatic nerve histopathological change.
Collapse
Affiliation(s)
- Yueyao Chen
- Department of Radiology, Shenzhen Traditional Chinese Medicine Hospital, The Fourth Clinical Medical College of Guangzhou University of Chinese Medicine, Shenzhen, China
| | - Zhongxian Pan
- Department of Radiology, Shenzhen Traditional Chinese Medicine Hospital, The Fourth Clinical Medical College of Guangzhou University of Chinese Medicine, Shenzhen, China
| | - Fanqi Meng
- Department of Radiology, Shenzhen Traditional Chinese Medicine Hospital, The Fourth Clinical Medical College of Guangzhou University of Chinese Medicine, Shenzhen, China
| | - Qian Xu
- Department of Radiology, Shenzhen Traditional Chinese Medicine Hospital, The Fourth Clinical Medical College of Guangzhou University of Chinese Medicine, Shenzhen, China
| | - Leyu Huang
- Department of Radiology, Shenzhen Traditional Chinese Medicine Hospital, The Fourth Clinical Medical College of Guangzhou University of Chinese Medicine, Shenzhen, China
| | - Xuejia Pu
- Department of Radiology, Shenzhen Traditional Chinese Medicine Hospital, The Fourth Clinical Medical College of Guangzhou University of Chinese Medicine, Shenzhen, China
| | - Xuewen Yu
- Department of Pathology, Shenzhen Traditional Chinese Medicine Hospital, The Fourth Clinical Medical College of Guangzhou University of Chinese Medicine, Shenzhen, China
| | | | - Hanqing Lyu
- Department of Radiology, Shenzhen Traditional Chinese Medicine Hospital, The Fourth Clinical Medical College of Guangzhou University of Chinese Medicine, Shenzhen, China
- *Correspondence: Hanqing Lyu,
| | - Xiaofeng Lin
- Department of Nuclear Medicine, The Seventh Affiliated Hospital, Sun Yat-sen University, Shenzhen, China
- Xiaofeng Lin,
| |
Collapse
|
22
|
Chen Y, Pan Z, Meng F, Li Z, Hu Y, Yu X, Gao J, Guo Y, Lyu H, Lin X. Performance of Single-Shot Echo-Planar Imaging in Diffusion Tensor Imaging in Rat Sciatic Nerve Compared With Readout-Segmented Echo-Planar Imaging. Front Neurosci 2022; 16:844408. [PMID: 35645709 PMCID: PMC9133884 DOI: 10.3389/fnins.2022.844408] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2021] [Accepted: 03/29/2022] [Indexed: 11/13/2022] Open
Abstract
Objectives To compare the performances of single-shot echo-planar imaging (SS–EPI) and readout-segmented echo-planar imaging (RS–EPI) for diffusion tensor imaging (DTI) of the rat sciatic nerve. Methods Eight healthy adult male Sprague-Dawley rats were anesthetized and scanned with a 3T MRI scanner using SS–EPI and RS–EPI DTI sequences. The image quality in terms of the morphology of the nerve, distortions of the nearby femur, muscles, and homogeneity of neuromuscular were evaluated and scored. The correlations between the DTI parameters including fractional anisotropy (FA), axial diffusivity (AD), radial diffusivity (RD), apparent diffusion coefficient (ADC), and histopathological parameters were calculated by using the Pearson correlation coefficient and compared by the modified Fisher Z-transform, respectively. Results The quality scores were higher for the images from the SS–EPI sequence compared with the RS–EPI sequence for characteristics such as sharpness of the sciatic nerve margin (P = 0.008), artifacts of the sciatic nerve (P = 0.008), and homogeneity of the neuromuscular region (P = 0.007), as well as the contrast-to-noise ratio (CNR) of DW images (P < 0.001). The correlation coefficients were higher for the FA and RD values from the SS–EPI sequence compared with those from the RS–EPI sequence. Furthermore, the correlation coefficients between FA and myelin thickness (P = 0.027), FA and diameter of the myelinated fiber (P = 0.036), as well as RD and myelin thickness (P = 0.05) were statistically higher for the SS–EPI sequence compared with those for the RS–EPI sequence. Conclusion Diffusion tensor imaging analysis of the rat sciatic nerve showed that the image quality from the SS–EPI sequence was significantly higher compared with that from the RS–EPI sequence. Furthermore, the FA and RD derived from the SS–EPI sequence are promising and sensitive biomarkers to detect the histopathological changes in the rat sciatic nerve.
Collapse
Affiliation(s)
- Yueyao Chen
- Department of Radiology, Shenzhen Traditional Chinese Medicine Hospital, The Fourth Clinical Medical College of Guangzhou University of Chinese Medicine, Shenzhen, China
| | - Zhongxian Pan
- Department of Radiology, Shenzhen Traditional Chinese Medicine Hospital, The Fourth Clinical Medical College of Guangzhou University of Chinese Medicine, Shenzhen, China
| | - Fanqi Meng
- Department of Radiology, Shenzhen Traditional Chinese Medicine Hospital, The Fourth Clinical Medical College of Guangzhou University of Chinese Medicine, Shenzhen, China
| | - Zhujing Li
- Department of Radiology, Shenzhen Traditional Chinese Medicine Hospital, The Fourth Clinical Medical College of Guangzhou University of Chinese Medicine, Shenzhen, China
| | - Yuanming Hu
- Department of Radiology, Shenzhen Traditional Chinese Medicine Hospital, The Fourth Clinical Medical College of Guangzhou University of Chinese Medicine, Shenzhen, China
| | - Xuewen Yu
- Department of Pathology, Shenzhen Traditional Chinese Medicine Hospital, The Fourth Clinical Medical College of Guangzhou University of Chinese Medicine, Shenzhen, China
| | - Jinyun Gao
- Department of Radiology, Shenzhen Traditional Chinese Medicine Hospital, The Fourth Clinical Medical College of Guangzhou University of Chinese Medicine, Shenzhen, China
| | - Yihao Guo
- Magnetic Resonance Collaboration, Siemens Healthcare, Guangzhou, China
| | - Hanqing Lyu
- Department of Radiology, Shenzhen Traditional Chinese Medicine Hospital, The Fourth Clinical Medical College of Guangzhou University of Chinese Medicine, Shenzhen, China
- *Correspondence: Hanqing Lyu,
| | - Xiaofeng Lin
- Department of Nuclear Medicine, The Seventh Affiliated Hospital, Sun Yat-sen University, Shenzhen, China
- Xiaofeng Lin,
| |
Collapse
|
23
|
Li X, Zhu H, Sun K, Chai W, Fu C, Yan F. Is simultaneous multi-slice readout-segmented echo-planar imaging valuable for predicting molecular subtypes of breast cancer? Eur J Radiol 2022; 150:110232. [DOI: 10.1016/j.ejrad.2022.110232] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2021] [Revised: 02/15/2022] [Accepted: 02/25/2022] [Indexed: 11/03/2022]
|
24
|
Lin M, Lin N, Sheng Y, Sha Y, Zhang Z, Zhou K. Detection of cholesteatoma: 2D BLADE turbo gradient- and spin-echo imaging versus readout-segmented echo-planar diffusion-weighted imaging. Eur Arch Otorhinolaryngol 2022; 279:5223-5229. [PMID: 35482118 DOI: 10.1007/s00405-022-07370-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2022] [Accepted: 03/21/2022] [Indexed: 11/28/2022]
Abstract
PURPOSE This study is to compare the accuracy of 2D BLADE turbo gradient- and spin-echo imaging (TGSE BLADE) diffusion-weighted imaging (DWI) with that of readout-segmented echo-planar (RESOLVE) DWI in the detection of primary and residual/recurrent temporal bone cholesteatoma. METHODS The prospective study population consisted of 58 patients who were underwent magnetic resonance (MR) imaging for the evaluation of suspected temporal bone cholesteatoma. Two radiologists independently evaluated the two sequences. Kappa (k) statistics, the intra-class correlation coefficient (ICC), and a paired t test were used for statistical analysis. RESULTS Of the 58 patients included, all had histo-pathologically confirmed cholesteatomas. In ≤ 3 mm group (n = 13), TGSE BLADE sequence correctly identified all cases except one that was recorded as equivocal on both sequences because of high signal intensity on T1WI; while on RESOLVE sequences, 6 were positive, 4 were equivocal, and 3 were false negative. For > 3 mm group (n = 45), detection performance was similar between the two sequences. The mean ADC of cholesteatoma on TGSE BLADE DWI was 0.923 × 10-3 mm2/s, and the mean ADC of cholesteatoma on RESOLVE DWI was 0.949 × 10-3 mm2/s, with no significant difference in the mean ADC values of cholesteatoma measured on the two sequences (p = 0.9216). CONCLUSION TGSE BLADE outperforms RESOLVE in the detection of small temporal bone cholesteatoma ≤ 3 mm.
Collapse
Affiliation(s)
- Mengyan Lin
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China.,Department of Radiology, Eye & ENT Hospital of Fudan University, 83 Fenyang Road, Shanghai, 200031, China
| | - Naier Lin
- Department of Radiology, Eye & ENT Hospital of Fudan University, 83 Fenyang Road, Shanghai, 200031, China
| | - Yaru Sheng
- Department of Radiology, Eye & ENT Hospital of Fudan University, 83 Fenyang Road, Shanghai, 200031, China
| | - Yan Sha
- Department of Radiology, Eye & ENT Hospital of Fudan University, 83 Fenyang Road, Shanghai, 200031, China.
| | - Zhongshuai Zhang
- Scientific Marketing, Siemens Healthcare, Shanghai, 200336, China
| | - Kun Zhou
- Scientific Marketing, Siemens Healthcare, Shanghai, 200336, China
| |
Collapse
|
25
|
Fardanesh R, Thakur SB, Sevilimedu V, Horvat JV, Gullo RL, Reiner JS, Eskreis-Winkler S, Thakur N, Pinker K. Differentiation Between Benign and Metastatic Breast Lymph Nodes Using Apparent Diffusion Coefficients. Front Oncol 2022; 12:795265. [PMID: 35280791 PMCID: PMC8905522 DOI: 10.3389/fonc.2022.795265] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2021] [Accepted: 01/28/2022] [Indexed: 11/24/2022] Open
Abstract
The aim of this study was to determine the range of apparent diffusion coefficient (ADC) values for benign axillary lymph nodes in contrast to malignant axillary lymph nodes, and to define the optimal ADC thresholds for three different ADC parameters (minimum, maximum, and mean ADC) in differentiating between benign and malignant lymph nodes. This retrospective study included consecutive patients who underwent breast MRI from January 2017–December 2020. Two-year follow-up breast imaging or histopathology served as the reference standard for axillary lymph node status. Area under the receiver operating characteristic curve (AUC) values for minimum, maximum, and mean ADC (min ADC, max ADC, and mean ADC) for benign vs malignant axillary lymph nodes were determined using the Wilcoxon rank sum test, and optimal ADC thresholds were determined using Youden’s Index. The final study sample consisted of 217 patients (100% female, median age of 52 years (range, 22–81), 110 with benign axillary lymph nodes and 107 with malignant axillary lymph nodes. For benign axillary lymph nodes, ADC values (×10−3 mm2/s) ranged from 0.522–2.712 for mean ADC, 0.774–3.382 for max ADC, and 0.071–2.409 for min ADC; for malignant axillary lymph nodes, ADC values (×10−3 mm2/s) ranged from 0.796–1.080 for mean ADC, 1.168–1.592 for max ADC, and 0.351–0.688 for min ADC for malignant axillary lymph nodes. While there was a statistically difference in all ADC parameters (p<0.001) between benign and malignant axillary lymph nodes, boxplots illustrate overlaps in ADC values, with the least overlap occurring with mean ADC, suggesting that this is the most useful ADC parameter for differentiating between benign and malignant axillary lymph nodes. The mean ADC threshold that resulted in the highest diagnostic accuracy for differentiating between benign and malignant lymph nodes was 1.004×10−3 mm2/s, yielding an accuracy of 75%, sensitivity of 71%, specificity of 79%, positive predictive value of 77%, and negative predictive value of 74%. This mean ADC threshold is lower than the European Society of Breast Imaging (EUSOBI) mean ADC threshold of 1.300×10−3 mm2/s, therefore suggesting that the EUSOBI threshold which was recently recommended for breast tumors should not be extrapolated to evaluate the axillary lymph nodes.
Collapse
Affiliation(s)
- Reza Fardanesh
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, United States
| | - Sunitha B Thakur
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, United States.,Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, United States
| | - Varadan Sevilimedu
- Department of Epidemiology and Biostatistics, Memorial Sloan Kettering Cancer Center, New York, NY, United States
| | - Joao V Horvat
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, United States
| | - Roberto Lo Gullo
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, United States
| | - Jeffrey S Reiner
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, United States
| | - Sarah Eskreis-Winkler
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, United States
| | - Nikita Thakur
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, United States.,Touro College of Osteopathic Medicine, Middletown, NY, United States
| | - Katja Pinker
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, United States
| |
Collapse
|
26
|
Fu Q, Kong XC, Liu DX, Zhou K, Guo YH, Lei ZQ, Zheng CS, Yang F. Turbo Gradient and Spin Echo PROPELLER-Diffusion Weighted Imaging for Orbital Tumors: A Comparative Study With Readout-Segmented Echo-Planar Imaging. Front Neurosci 2021; 15:755327. [PMID: 34916899 PMCID: PMC8670178 DOI: 10.3389/fnins.2021.755327] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2021] [Accepted: 11/02/2021] [Indexed: 11/30/2022] Open
Abstract
Purpose: To qualitatively and quantitatively compare the image quality and diagnostic performance of turbo gradient and spin echo PROPELLER diffusion-weighted imaging (TGSE-PROPELLER-DWI) vs. readout-segmented echo-planar imaging (rs-EPI) in the evaluation of orbital tumors. Materials and Methods: A total of 43 patients with suspected orbital tumors were enrolled to perform the two DWIs with comparable spatial resolution on 3T. The overall image qualities, geometric distortions, susceptibility artifacts, and lesion conspicuities were scored by using a four-point scale (1, poor; 4, excellent). Quantitative measurements, including contrast-to-noise ratios (CNRs), apparent diffusion coefficients (ADCs), geometric distortion rates (GDRs), and lesion sizes, were calculated and compared. The two ADCs for differentiating malignant from benign orbital tumors were evaluated. Wilcoxon signed-rank test, Kappa statistic, and receiver operating characteristics (ROC) curves were used. Results: TGSE-PROPELLER-DWI performed superior in all subjective scores and quantitative GDR evaluation than rs-EPI (p < 0.001), and excellent interobserver agreement was obtained for Kappa value ranging from 0.876 to 1.000. ADClesion of TGSE-PROPELLER-DWI was significantly higher than those of rs-EPI (p < 0.001). Mean ADC of malignant tumors was significantly lower than that of benign tumors both in two DWIs. However, the AUC for differentiating malignant and benign tumors showed no significant difference in the two DWIs (0.860 vs. 0.854, p = 0.7448). Sensitivity and specificity could achieve 92.86% and 72.73% for TGSE-PROPELLER-DWI with a cutoff value of 1.23 × 10–3 mm2/s, and 85.71% and 81.82% for rs-EPI with a cutoff value of 0.99 × 10–3 mm2/s. Conclusion: Compared with rs-EPI, TGSE-PROPELLER-DWI showed minimized geometric distortion and susceptibility artifacts significantly improved the image quality for orbital tumors and achieved comparable diagnostic performance in differentiating malignant and benign orbital tumors.
Collapse
Affiliation(s)
- Qing Fu
- Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.,Hubei Province Key Laboratory of Molecular Imaging, Wuhan, China
| | - Xiang-Chuang Kong
- Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.,Hubei Province Key Laboratory of Molecular Imaging, Wuhan, China
| | - Ding-Xi Liu
- Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.,Hubei Province Key Laboratory of Molecular Imaging, Wuhan, China
| | - Kun Zhou
- Siemens Shenzhen Magnetic Resonance Ltd., Shenzhen, China
| | - Yi-Hao Guo
- MR Collaboration, Siemens Healthcare Ltd., Guangzhou, China
| | - Zi-Qiao Lei
- Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.,Hubei Province Key Laboratory of Molecular Imaging, Wuhan, China
| | - Chuan-Sheng Zheng
- Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.,Hubei Province Key Laboratory of Molecular Imaging, Wuhan, China
| | - Fan Yang
- Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.,Hubei Province Key Laboratory of Molecular Imaging, Wuhan, China
| |
Collapse
|
27
|
High-Resolution DWI with Simultaneous Multi-Slice Readout-Segmented Echo Planar Imaging for the Evaluation of Malignant and Benign Breast Lesions. Diagnostics (Basel) 2021; 11:diagnostics11122273. [PMID: 34943509 PMCID: PMC8700489 DOI: 10.3390/diagnostics11122273] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2021] [Revised: 11/29/2021] [Accepted: 11/30/2021] [Indexed: 11/19/2022] Open
Abstract
To investigate the feasibility and effectiveness of high-resolution readout-segmented echo planar imaging (rs-EPI), diffusion-weighted imaging (DWI) is used simultaneously with multi-slice (SMS) imaging (SMS rs-EPI) for the differentiation of breast malignant and benign lesions in comparison to conventional rs-EPI on a 3T MR scanner. A total of 102 patients with 113 breast lesions underwent bilateral breast MRI using a prototype SMS rs-EPI sequence and a conventional rs-EPI sequence. Subjective image quality was assessed using a 5-point Likert scale (1 = poor, 5 = excellent). Signal-to-noise ratio (SNR), lesion contrast-to-noise ratio (CNR) and apparent diffusion coefficients (ADC) value of the lesion were measured for comparison. Receiver operating characteristic curve analysis was performed to evaluate the diagnosis performance of ADC, and the corresponding area under curve (AUC) was calculated. The image quality scores in anatomic distortion, lesion conspicuity, sharpness of anatomical details and overall image quality of SMS rs-EPI were significantly higher than those of conventional rs-EPI. CNR was enhanced in the high-resolution SMS rs-EPI acquisition (6.48 ± 1.71 vs. 4.23 ± 1.49; p < 0.001). The mean ADC value was comparable in SMS rs-EPI and conventional rs-EPI (benign 1.45 × 10−3 vs. 1.43 × 10−3 mm2/s, p = 0.702; malignant 0.91 × 10−3 vs. 0.89 × 10−3 mm2/s, p = 0.076). The AUC was 0.957 in SMS rs-EPI and 0.983 in conventional rs-EPI. SMS rs-EPI technique allows for higher spatial resolution and slight reduction of scan time in comparison to conventional rs-EPI, which has potential for better differentiation between malignant and benign lesions of the breast.
Collapse
|
28
|
Radbruch A, Paech D, Gassenmaier S, Luetkens J, Isaak A, Herrmann J, Othman A, Schäfer J, Nikolaou K. 1.5 vs 3 Tesla Magnetic Resonance Imaging: A Review of Favorite Clinical Applications for Both Field Strengths-Part 2. Invest Radiol 2021; 56:692-704. [PMID: 34417406 DOI: 10.1097/rli.0000000000000818] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
ABSTRACT The second part of this review deals with experiences in neuroradiological and pediatric examinations using modern magnetic resonance imaging systems with 1.5 T and 3 T, with special attention paid to experiences in pediatric cardiac imaging. In addition, whole-body examinations, which are widely used for diagnostic purposes in systemic diseases, are compared with respect to the image quality obtained in different body parts at both field strengths. A systematic overview of the technical differences at 1.5 T and 3 T has been presented in part 1 of this review, as well as several organ-based magnetic resonance imaging applications including musculoskeletal imaging, abdominal imaging, and prostate diagnostics.
Collapse
Affiliation(s)
- Alexander Radbruch
- From the Clinic for Diagnostic and Interventional Neuroradiology, University Hospital Bonn, Bonn
| | - Daniel Paech
- From the Clinic for Diagnostic and Interventional Neuroradiology, University Hospital Bonn, Bonn
| | - Sebastian Gassenmaier
- Department of Radiology, Diagnostic and Interventional Radiology, University of Tübingen, Tübingen
| | - Julian Luetkens
- Clinic for Diagnostic and Interventional Radiology, University Hospital Bonn, Bonn
| | - Alexander Isaak
- Clinic for Diagnostic and Interventional Radiology, University Hospital Bonn, Bonn
| | - Judith Herrmann
- Department of Radiology, Diagnostic and Interventional Radiology, University of Tübingen, Tübingen
| | | | - Jürgen Schäfer
- Department of Radiology, Diagnostic and Interventional Radiology, University of Tübingen, Tübingen
| | - Konstantin Nikolaou
- Department of Radiology, Diagnostic and Interventional Radiology, University of Tübingen, Tübingen
| |
Collapse
|
29
|
Sun K, Jiao Z, Zhu H, Chai W, Yan X, Fu C, Cheng JZ, Yan F, Shen D. Radiomics-based machine learning analysis and characterization of breast lesions with multiparametric diffusion-weighted MR. J Transl Med 2021; 19:443. [PMID: 34689804 PMCID: PMC8543912 DOI: 10.1186/s12967-021-03117-5] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2021] [Accepted: 10/13/2021] [Indexed: 12/29/2022] Open
Abstract
Background This study aimed to evaluate the utility of radiomics-based machine learning analysis with multiparametric DWI and to compare the diagnostic performance of radiomics features and mean diffusion metrics in the characterization of breast lesions. Methods This retrospective study included 542 lesions from February 2018 to November 2018. One hundred radiomics features were computed from mono-exponential (ME), biexponential (BE), stretched exponential (SE), and diffusion-kurtosis imaging (DKI). Radiomics-based analysis was performed by comparing four classifiers, including random forest (RF), principal component analysis (PCA), L1 regularization (L1R), and support vector machine (SVM). These four classifiers were trained on a training set with 271 patients via ten-fold cross-validation and tested on an independent testing set with 271 patients. The diagnostic performance of the mean diffusion metrics of ME (mADCall b, mADC0–1000), BE (mD, mD*, mf), SE (mDDC, mα), and DKI (mK, mD) were also calculated for comparison. The area under the receiver operating characteristic curve (AUC) was used to compare the diagnostic performance. Results RF attained higher AUCs than L1R, PCA and SVM. The AUCs of radiomics features for the differential diagnosis of breast lesions ranged from 0.80 (BE_D*) to 0.85 (BE_D). The AUCs of the mean diffusion metrics ranged from 0.54 (BE_mf) to 0.79 (ME_mADC0–1000). There were significant differences in the AUCs between the mean values of all diffusion metrics and radiomics features of AUCs (all P < 0.001) for the differentiation of benign and malignant breast lesions. Of the radiomics features computed, the most important sequence was BE_D (AUC: 0.85), and the most important feature was FO-10 percentile (Feature Importance: 0.04). Conclusions The radiomics-based analysis of multiparametric DWI by RF enables better differentiation of benign and malignant breast lesions than the mean diffusion metrics. Supplementary Information The online version contains supplementary material available at 10.1186/s12967-021-03117-5.
Collapse
Affiliation(s)
- Kun Sun
- Department of Radiology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China
| | - Zhicheng Jiao
- Department of Diagnostic Imaging, Alpert Medical School of Brown University, Providence, USA
| | - Hong Zhu
- Department of Radiology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China
| | - Weimin Chai
- Department of Radiology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China
| | - Xu Yan
- Scientific Marketing, Siemens Shanghai Magnetic Resonance Ltd., Shanghai, China
| | - Caixia Fu
- MR Application Development, Siemens Shenzhen Magnetic Resonance Ltd., Shenzhen, China
| | - Jie-Zhi Cheng
- Department of Research and Development, Shanghai United Imaging Intelligence Co., Ltd., Shanghai, China
| | - Fuhua Yan
- Department of Radiology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China.
| | - Dinggang Shen
- Department of Research and Development, Shanghai United Imaging Intelligence Co., Ltd., Shanghai, China. .,School of BME, Shanghai Tech University, Shanghai, China.
| |
Collapse
|
30
|
Sanderink WBG, Teuwen J, Appelman L, Moy L, Heacock L, Weiland E, Sechopoulos I, Mann RM. Diffusion weighted imaging for evaluation of breast lesions: Comparison between high b-value single-shot and routine readout-segmented sequences at 3 T. Magn Reson Imaging 2021; 84:35-40. [PMID: 34560230 DOI: 10.1016/j.mri.2021.09.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2021] [Revised: 09/10/2021] [Accepted: 09/16/2021] [Indexed: 10/20/2022]
Abstract
PURPOSE In this study, we compare readout-segmented echo-planar imaging (rs-EPI) Diffusion Weighted Imaging (DWI) to a work-in-progress single-shot EPI with modified Inversion Recovery Background Suppression (ss-EPI-mIRBS) sequence at 3 T using a b-value of 2000 s/mm2 on image quality, lesion visibility and evaluation time. METHOD From September 2017 to December 2018, 23 women (one case used for training) with known breast cancer were included in this study, after providing signed informed consent. Women were scanned with the conventional rs-EPI sequence and the work-in-progress ss-EPI-mIRBS during the same examination. Four breast radiologists (4-13 years of experience) independently scored both series for overall image quality (1: extremely poor to 9: excellent). All lesions (47 in total, 36 malignant, and 11 benign and high-risk) were evaluated for visibility (1: not visible, 2: visible if location is given, 3: visible) and probability of malignancy (BI-RADS 1 to 5). ADC values were determined by measuring signal intensity in the lesions using dynamic contrast-enhanced (DCE) images for reference. Evaluation times for all assessments were automatically recorded. Results were analyzed using the visual grading characteristics (VGC) and the resulting area under the curve (AUCVGC) method. Statistical analysis was performed in SPSS, with McNemar tests, and paired t-tests used for comparison. RESULTS No significant differences were detected between the two sequences in image quality (AUCVGC: 0.398, p = 0.087) and lesion visibility (AUCVGC: 0.534, p = 0.336) scores. Lesion characteristics (e.g benign and high-risk, versus malignant; small (≤10 mm) vs. larger (>10 mm)) did not result in different image quality or lesion visibility between sequences. Sensitivity (rs-EPI: 72.2% vs. ss-EPImIRBS: 78.5%, p = 0.108) and specificity (70.5% vs. 56.8%, p = 0.210, respectively) were comparable. In both sequences the mean ADC value was higher for benign and high-risk lesions than for malignant lesions (ss-EPI-mIRBS: p = 0.022 and rs-EPI: p = 0.055). On average, ss-EPI-mIRBS resulted in decreased overall reading time by 7.7 s/case (p = 0.067); a reduction of 17%. For malignant lesions, average reading time was significantly shorter using ss-EPI-mIRBS compared to rs-EPI (64.0 s/lesion vs. 75.9 s/lesion, respectively, p = 0.039). CONCLUSION Based on this study, the ss-EPI sequence using a b-value of 2000 s/mm2 enables for a mIRBS acquisition with quality and lesion conspicuity that is comparable to conventional rs-EPI, but with a decreased reading time.
Collapse
Affiliation(s)
- Wendelien B G Sanderink
- Department of Medical Imaging, Radboud University Medical Center, Geert Grooteplein Zuid 10, 6525GA Nijmegen, the Netherlands.
| | - Jonas Teuwen
- Department of Medical Imaging, Radboud University Medical Center, Geert Grooteplein Zuid 10, 6525GA Nijmegen, the Netherlands; Department of Radiology, the Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066, CX, Amsterdam, the Netherlands
| | - Linda Appelman
- Department of Medical Imaging, Radboud University Medical Center, Geert Grooteplein Zuid 10, 6525GA Nijmegen, the Netherlands
| | - Linda Moy
- Department of Radiology, New York University Langone Medical Center, 660 First Avenue, 4(th) floor, New York, NY 10016, United States
| | - Laura Heacock
- Department of Radiology, New York University Langone Medical Center, 660 First Avenue, 4(th) floor, New York, NY 10016, United States
| | - Elisabeth Weiland
- MR Application Predevelopment, Siemens Healthcare, Allee am Roethelheimpark 2, 91052 Erlangen, Germany
| | - Ioannis Sechopoulos
- Department of Medical Imaging, Radboud University Medical Center, Geert Grooteplein Zuid 10, 6525GA Nijmegen, the Netherlands
| | - Ritse M Mann
- Department of Medical Imaging, Radboud University Medical Center, Geert Grooteplein Zuid 10, 6525GA Nijmegen, the Netherlands; Department of Radiology, the Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066, CX, Amsterdam, the Netherlands
| |
Collapse
|
31
|
Fu Q, Kong XC, Liu DX, Zhou K, Guo YH, Wang MF, Lei ZQ, Zheng CS. Clinical comparison of single-shot EPI, readout-segmented EPI and TGSE-BLADE for diffusion-weighted imaging of cerebellopontine angle tumors on 3 tesla. Magn Reson Imaging 2021; 84:76-83. [PMID: 34555457 DOI: 10.1016/j.mri.2021.09.009] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2021] [Revised: 09/06/2021] [Accepted: 09/16/2021] [Indexed: 11/16/2022]
Abstract
OBJECTIVE The complex anatomical structures of cerebellopontine angle (CPA) pose a unique challenge to diffusion weighted imaging (DWI). This study aimed to compare the clinical utility of the prototypic 2D turbo gradient- and spin echo-BLADE-DWI (TGSE-BLADE-DWI) with that of readout-segmented echo-planar DWI (RESOLVE-DWI) and single-shot echo-planar DWI (SS-EPI-DWI) to visualize CPA anatomic structures and identify CPA tumors. METHODS A total of 8 volunteers and 36 patients with pathological CPA tumors were enrolled to perform the three DWI sequences at 3 T. Scan time of TGSE-BLADE-DWI, RESOLVE-DWI and SS-EPI-DWI was 5 min 51 s, 5 min 15 s and 1 min 22 s, respectively. Subjective analysis, including visualization of anatomical structures, geometric distortion, ghosting artifacts, lesion conspicuity, diagnostic confidence, and overall image quality of the three DWI sequences were scored and assessed. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and apparent diffusion coefficient (ADC) of CPA tumors were measured and compared. RESULTS A total of 39 lesions were identified, TGSE-BLADE-DWI detected all of them, RESOLVE-DWI 36 and SS-EPI-DWI 27. Significant differences were found in all the subjective parameters among the three DWI sequences (all p < 0.001). TGSE-BLADE-DWI was significantly better than RESOLVE-DWI in visualization of CPA anatomical structures, geometric distortion, ghosting artifacts, lesion conspicuity, diagnostic confidence, and overall image quality (all p < 0.01), and RESOLVE-DWI showed significantly superior performance than SS-EPI-DWI in all parameters (all p < 0.001). CNRs and ADCs were not significantly different among the three DWI sequences (p = 0.355, p = 0.590, respectively). No significant differences were detected between TGSE-BLADE-DWI SNR and RESOLVE-DWI SNR (p = 0.058), or TGSE-BLADE-DWI SNR and SS-EPI-DWI SNR (p = 0.155). CONCLUSION Compared with RESOLVE-DWI and SS-EPI-DWI, TGSE-BLADE-DWI minimized geometric distortions and ghosting artifacts and demonstrated an improved ability for depicting CPA tumors with better lesion conspicuity. SUMMARY Geometric distortions and ghosting artifacts are found at bone-air interfaces using conventional diffusion-weighted imaging (DWI), which is a challenge for imaging cerebellopontine angle (CPA) tumors. Our study validated that geometric distortions and ghosting artifacts were not present on 2D turbo gradient- and spin-echo-BLADE-DWI scans, making this technique useful for visualizing CPA anatomic structures and diagnosing CPA tumors.
Collapse
Affiliation(s)
- Qing Fu
- Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China; Hubei Province Key Laboratory of Molecular Imaging, Wuhan 430022, China.
| | - Xiang-Chuang Kong
- Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China; Hubei Province Key Laboratory of Molecular Imaging, Wuhan 430022, China.
| | - Ding-Xi Liu
- Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China; Hubei Province Key Laboratory of Molecular Imaging, Wuhan 430022, China.
| | - Kun Zhou
- Siemens Shenzhen Magnetic Resonance Ltd., Shenzhen, China.
| | - Yi-Hao Guo
- MR Collaboration, Siemens Healthcare Ltd., Guangzhou, China.
| | - Ming-Fu Wang
- Department of Radiology, The Third People's Hospital of Hubei Province, Wuhan 430033, China.
| | - Zi-Qiao Lei
- Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China; Hubei Province Key Laboratory of Molecular Imaging, Wuhan 430022, China.
| | - Chuan-Sheng Zheng
- Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China; Hubei Province Key Laboratory of Molecular Imaging, Wuhan 430022, China.
| |
Collapse
|
32
|
Geng Y, Shi Y, Chen W, Tang Z, Zhang Z, Zhou K, Sha Y. BLADE turbo gradient- and spin-echo in the assessment of sinonasal lesions: a comprehensive comparison of image quality in readout-segmented echo-planar imaging. Acta Radiol 2021; 63:1381-1389. [PMID: 34528834 DOI: 10.1177/02841851211041820] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND A two-dimensional turbo gradient-echo and spin-echo diffusion-weighted pulse sequence with a non-Cartesian BLADE trajectory (TGSE BLADE) can eliminate image artifacts and distortion with clinically acceptable scan times. This process has the potential to overcome the shortcomings of current diffusion-weighted imaging (DWI) techniques, especially in the sinonasal region. PURPOSE To investigate the feasibility of TGSE BLADE in the assessment of sinonasal lesions and compare the quality of TGSE BLADE with RESOLVE images both qualitatively and quantitatively. MATERIAL AND METHODS A total of 36 patients with sinonasal lesions were included in this prospective study. DW images acquired using TGSE BLADE and RESOLVE were performed with the same acquisition time. Two independent observers evaluated the qualitative parameters (overall image quality, lesion visibility, and geometric distortion) and quantitative parameters (geometric distortion ratio [GDR], signal-to-noise ratio [SNR], contrast, contrast-to-noise ratio [CNR], and apparent diffusion coefficient [ADC] value) of the two sequences. RESULTS Qualitative assessment revealed that TGSE BLADE exhibited higher overall image quality (P < 0.001) and lesion visibility (P < 0.001) and less geometric distortion (P < 0.001) than RESOLVE. Quantitative assessment showed that TGSE BLADE images exhibited higher contrast (P < 0.001) and CNR (P < 0.001) and lower GDR (P < 0.05) and SNR (P < 0.001) than RESOLVE images. The ADC value of TGSE BLADE was significantly lower than that of RESOLVE (P < 0.05). CONCLUSION TGSE BLADE can reduce susceptibility artifacts and geometric distortion more than RESOLVE and appears to be a promising diffusion imaging sequence for the assessment of sinonasal lesions.
Collapse
Affiliation(s)
- Yue Geng
- Department of Radiology, 159395Eye & ENT Hospital, 12478Fudan University, Shanghai Medical College, Shanghai, PR China
| | - Yiqian Shi
- Department of Radiology, 159395Eye & ENT Hospital, 12478Fudan University, Shanghai Medical College, Shanghai, PR China
| | - Wei Chen
- Department of Radiology, 159395Eye & ENT Hospital, 12478Fudan University, Shanghai Medical College, Shanghai, PR China
| | - Zuohua Tang
- Department of Radiology, 159395Eye & ENT Hospital, 12478Fudan University, Shanghai Medical College, Shanghai, PR China
| | - Zhongshuai Zhang
- Scientific Marketing, 89678Siemens Healthcare, Shanghai, PR China
| | - Kun Zhou
- Department of Digitalization, 89678Siemens Shenzhen Magnetic Resonance Ltd., Shenzhen, PR China
| | - Yan Sha
- Department of Radiology, 159395Eye & ENT Hospital, 12478Fudan University, Shanghai Medical College, Shanghai, PR China
| |
Collapse
|
33
|
Radiomics Nomogram Based on Radiomics Score from Multiregional Diffusion-Weighted MRI and Clinical Factors for Evaluating HER-2 2+ Status of Breast Cancer. Diagnostics (Basel) 2021; 11:diagnostics11081491. [PMID: 34441425 PMCID: PMC8395031 DOI: 10.3390/diagnostics11081491] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2021] [Revised: 08/06/2021] [Accepted: 08/11/2021] [Indexed: 12/22/2022] Open
Abstract
This study aimed to establish and validate a radiomics nomogram using the radiomics score (rad-score) based on multiregional diffusion-weighted imaging (DWI) and apparent diffusion coefficient (ADC) features combined with clinical factors for evaluating HER-2 2+ status of breast cancer. A total of 223 patients were retrospectively included. Radiomic features were extracted from multiregional DWI and ADC images. Based on the intratumoral, peritumoral, and combined regions, three rad-scores were calculated using the logistic regression model. Independent parameters were selected among clinical factors and combined rad-score (com-rad-score) using multivariate logistic analysis and used to construct a radiomics nomogram. The performance of the nomogram was evaluated using calibration, discrimination, and clinical usefulness. The areas under the receiver operator characteristic curve (AUCs) of intratumoral and peritumoral rad-scores were 0.824/0.763 and 0.794/0.731 in the training and validation cohorts, respectively. Com-rad-score achieved the highest AUC (0.860/0.790) among three rad-scores. ER status and com-rad-score were selected to establish the nomogram, which yielded good discrimination (AUC: 0.883/0.848) and calibration. Decision curve analysis demonstrated the clinical value of the nomogram in the validation cohort. In conclusion, radiomics nomogram, including clinical factors and com-rad-score, showed favorable performance for evaluating HER-2 2+ status in breast cancer.
Collapse
|
34
|
Ma W, Mao J, Wang T, Huang Y, Zhao ZH. Distinguishing between benign and malignant breast lesions using diffusion weighted imaging and intravoxel incoherent motion: A systematic review and meta-analysis. Eur J Radiol 2021; 141:109809. [PMID: 34116452 DOI: 10.1016/j.ejrad.2021.109809] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2021] [Revised: 05/27/2021] [Accepted: 05/31/2021] [Indexed: 01/03/2023]
Abstract
PURPOSE We sought to evaluate the diagnostic performance of diffusion weighted imaging (DWI) and intravoxel incoherent motion (IVIM) for distinguishing between benign and malignant breast tumors by performing a meta-analysis. METHODS We comprehensively searched the electronic databases PubMed and Embase from January 2000 to April 2020 for studies in English. Studies were included if they reported the sensitivity and specificity for identifying benign and malignant breast lesions using DWI or IVIM. Studies were reviewed according to QUADAS-2. The data inhomogeneity and publication bias were also assessed. In order to explore the influence of different field strengths and different b values on diagnostic efficiency, we conducted subgroup analysis. RESULTS We analyzed 79 studies, which included a total of 6294 patients with 4091 malignant lesions and 2793 benign lesions. Overall, the pooled sensitivity and specificity of ADC for detecting malignant breast tumors were 0.87 (0.86-0.88) and 0.80 (0.78-0.81), respectively. The PLR was 5.09 (4.16-6.24); the NLR was 0.15 (0.13-0.18); and the DOR was 38.95 (28.87-52.54). The AUC value was 0.9297. The highest performing parameter for IVIM was tissue diffusivity (D), and the pooled sensitivity and specificity was 0.85 (0.82-0.88) and 0.87(0.83-0.90), respectively; the PLR was 5.65 (3.91-8.18); the NLR was 0.17 (0.12-0.26); and the DOR was 38.44 (23.57-62.69). The AUC value was 0.9265. Most of parameters demonstrated considerable statistically significant heterogeneity (P < 0.05, I2>50 %) except the pooled DOR, PLR of D and the pooled DOR and NLR of D*. CONCLUSIONS Our meta-analysis indicated that DWI and IVIM had high sensitivity and specificity in the differential diagnosis of breast lesions; and compared with DWI, IVIM could not further increase the diagnostic performance. There was no significant difference in diagnostic accuracy.
Collapse
Affiliation(s)
- Weili Ma
- Department of Radiology, Shaoxing People's Hospital (Shaoxing Hospital, Zhejiang University School of Medicine), Key Laboratory of Functional Molecular Imaging of Tumor and Interventional Diagnosis and Treatment of Shaoxing City, Shaoxing 312000, China
| | - Jiwei Mao
- Department of Radiation Oncology, Shaoxing People's Hospital (Shaoxing Hospital, Zhejiang University School of Medicine), Shaoxing 312000, China
| | - Ting Wang
- Department of Radiology, Shaoxing People's Hospital (Shaoxing Hospital, Zhejiang University School of Medicine), Key Laboratory of Functional Molecular Imaging of Tumor and Interventional Diagnosis and Treatment of Shaoxing City, Shaoxing 312000, China
| | - Yanan Huang
- Department of Radiology, Shaoxing People's Hospital (Shaoxing Hospital, Zhejiang University School of Medicine), Key Laboratory of Functional Molecular Imaging of Tumor and Interventional Diagnosis and Treatment of Shaoxing City, Shaoxing 312000, China
| | - Zhen Hua Zhao
- Department of Radiology, Shaoxing People's Hospital (Shaoxing Hospital, Zhejiang University School of Medicine), Key Laboratory of Functional Molecular Imaging of Tumor and Interventional Diagnosis and Treatment of Shaoxing City, Shaoxing 312000, China.
| |
Collapse
|
35
|
Peng Y, Luo Y, Hu X, Shen Y, Hu D, Li Z, Kamel I. Quantitative T2*-Weighted Imaging and Reduced Field-of-View Diffusion-Weighted Imaging of Rectal Cancer: Correlation of R2* and Apparent Diffusion Coefficient With Histopathological Prognostic Factors. Front Oncol 2021; 11:670156. [PMID: 34109120 PMCID: PMC8180870 DOI: 10.3389/fonc.2021.670156] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2021] [Accepted: 04/28/2021] [Indexed: 12/24/2022] Open
Abstract
Purpose To assess T2*-weighted imaging (T2*WI) and reduced field-of-view diffusion-weighted Imaging (rDWI) derived parameters and their relationships with histopathological factors in patients with rectal cancer. Methods Fifty-four patients with pathologically-proven rectal cancer underwent preoperative T2*-weighted imaging and rDWI in this retrospective study. R2* values from T2*-weighted imaging and apparent diffusion coefficient (ADC) values from rDWI were compared in terms of different histopathological prognostic factors using student’s t-test or Mann-Whitney U-test. The correlations of R2* and ADC with prognostic factors were assessed by Spearman correlation analysis. The diagnostic performances of R2* and ADC were analyzed by receiver operating characteristic curves (ROC) separately and jointly. Results Significant positive correlation was found between R2* values and T stage, lymph node involvement, histological grades, CEA level, the presence of EMVI and tumor deposit (r = 0.374 ~ 0.673, p = 0.000–0.006), with the exception of CA19-9 level, CRM status and tumor involvement in the circumference lumen (TIL). Meanwhile, ADC values negatively correlated with almost all the prognostic factors (r = −0.588 to −0.299, p = 0.000–0.030), except CA19-9 level. The AUC range was 0.724–0.907 for R2* and 0.674–0.887 for ADC in discrimination of different prognostic factors. While showing the highest AUC of 0.913 (0.803–1.000) in differentiation of T stage, combination of R2* and ADC with reference to different prognostic factors did not significantly improve the diagnostic performance in comparison with individual R2*/ADC parameter. Conclusions R2* and ADC were associated with important histopathological prognostic factors of rectal cancer. R2* might act as additional quantitative imaging marker for tumor characterization of rectal cancer.
Collapse
Affiliation(s)
- Yang Peng
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Yan Luo
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Xuemei Hu
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Yaqi Shen
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Daoyu Hu
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Zhen Li
- Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Ihab Kamel
- Department of Radiology and Radiological Sciences, Johns Hopkins University, Baltimore, MD, United States
| |
Collapse
|
36
|
Tu C, Shen H, Liu D, Chen Q, Yuan X, Li X, Wang X, Liu R, Wang X, Li Q, Liu W, Zhang J. Simultaneous multi-slice readout-segmentation of long variable echo-trains for accelerated diffusion-weighted imaging of nasopharyngeal carcinoma: A feasibility and optimization study. Clin Imaging 2021; 79:119-124. [PMID: 33940488 DOI: 10.1016/j.clinimag.2021.04.009] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2021] [Revised: 03/27/2021] [Accepted: 04/12/2021] [Indexed: 12/29/2022]
Abstract
OBJECTIVES We aimed to evaluate the feasibility of simultaneous multi-slice readout segmentation of long variable echo-trains (SMS-RESOLVE) for diffusion-weighted imaging (DWI) of nasopharyngeal carcinoma (NPC) and determine the optimal acceleration factor of SMS-RESOLVE DWI compared with conventional RESOLVE DWI. MATERIALS AND METHODS One hundred and five patients with histologically confirmed NPC were enrolled. DWIs including conventional RESOLVE DWI, SMS-RESOLVE DWI with acceleration factors of 2 and 3 (2 × SMS-RESOLVE and 3 × SMS-RESOLVE) were acquired at b-values of 0 and 800 s/mm2. The subjective image quality, including overall image quality, lesion conspicuity, and lesion distortion scores, and objective image quality, including signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and contrast in these three protocols, were assessed and compared. The apparent diffusion coefficients (ADCs) of the primary tumor and right masseter muscle and normalized ADCs in the three protocols were measured and compared. RESULTS The 2 × SMS-RESOLVE provided comparable image quality and ADCs with a 48.3% reduction in scan time compared with conventional RESOLVE DWI. The 3 × SMS-RESOLVE showed significantly poorer image quality and the highest ADCs with a 56.9% reduction in scan times compared with conventional RESOLVE DWI. CONCLUSION The SMS-RESOLVE DWI with an acceleration factor of 2 yielded the best compromise between image quality and scan time reduction and could be an alternative to conventional RESOLVE DWI for nasopharyngeal carcinoma.
Collapse
Affiliation(s)
- Chunrong Tu
- Department of Radiology, Chongqing University Cancer Hospital, Chongqing, China
| | - Hesong Shen
- Department of Radiology, Chongqing University Cancer Hospital, Chongqing, China
| | - Daihong Liu
- Department of Radiology, Chongqing University Cancer Hospital, Chongqing, China
| | - Qiuzhi Chen
- Department of Radiology, Chongqing University Cancer Hospital, Chongqing, China
| | - Xiaoqian Yuan
- Department of Radiology, Chongqing University Cancer Hospital, Chongqing, China
| | - Xiaoqin Li
- Department of Radiology, Chongqing University Cancer Hospital, Chongqing, China
| | - Xing Wang
- Department of Radiology, Chongqing University Cancer Hospital, Chongqing, China
| | - Renwei Liu
- Department of Radiology, Chongqing University Cancer Hospital, Chongqing, China
| | - Xiaoxia Wang
- Department of Radiology, Chongqing University Cancer Hospital, Chongqing, China
| | - Qing Li
- MR Collaborations, Siemens Healthcare Ltd., Shanghai, China
| | - Wei Liu
- MR Application Development, Siemens Shenzhen Magnetic Resonance Ltd., Shenzhen, China
| | - Jiuquan Zhang
- Department of Radiology, Chongqing University Cancer Hospital, Chongqing, China.
| |
Collapse
|
37
|
Yang ZL, Hu YQ, Huang J, Zhan CA, Zhou MX, Zhang XY, Zhang HT, Xia LM, Ai T. Detection and Classification of Breast Lesions With Readout-Segmented Diffusion-Weighted Imaging in a Large Chinese Cohort. Front Oncol 2021; 11:636471. [PMID: 33828984 PMCID: PMC8020903 DOI: 10.3389/fonc.2021.636471] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2020] [Accepted: 02/08/2021] [Indexed: 01/22/2023] Open
Abstract
Objectives: To evaluate the performance of readout-segmented echo-planar imaging DWI (rs-EPI DWI) in detecting and characterizing breast cancers in a large Chinese cohort with comparison to dynamic contrast-enhanced MRI (DCE-MRI). Methods: The institutional review board approved this retrospective study with waived written informed consent. A total of 520 women (mean age, 43.1- ± 10.5-years) were included from July 2013 to October 2019. First, the ability of rs-EPI DWI in detecting breast lesions identified by DCE-MRI was evaluated. The lesion conspicuity of rs-EPI-DWI and DCE-MRI was compared using the Wilcoxon signed rank test. With pathology as a reference, the performance of rs-EPI DWI and DCE-MRI in distinguishing breast cancers was evaluated and compared using the Chi-square test. Results: Of 520 women, 327/520 (62.9%) patients had 423 lesions confirmed by pathology with 203 benign and 220 malignant lesions. The rs-EPI DWI can detect 90.8% (659/726) (reader 1) and 90.6% (663/732) (reader 2) of lesions identified by DCE-MRI. The lesion visibility was superior for DCE-MRI than rs-EPI-DWI (all p < 0.05). With pathology as a reference, the sensitivities and specificities of rs-EPI DWI in diagnosing breast cancers were 95.9% (211/220) and 85.7% (174/203) for reader 1 and 97.7% (215/220) and 86.2% (175/203) for reader 2. No significant differences were found for the performance of DCE-MRI and rs-EPI DWI in discriminating breast cancers (all p > 0.05). Conclusions: Although with an inferior lesion visibility, rs-EPI DWI can detect about 90% of breast lesions identified by DCE-MRI and has comparable diagnostic capacity to that of DCE-MRI in identifying breast cancer.
Collapse
Affiliation(s)
- Zhen Lu Yang
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Yi Qi Hu
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Jia Huang
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Chen Ao Zhan
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Min Xiong Zhou
- College of Medical Imaging, Shanghai University of Medicine & Health Sciences, Shanghai, China
| | | | | | - Li Ming Xia
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Tao Ai
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| |
Collapse
|
38
|
Song C, Cheng P, Cheng J, Zhang Y, Xie S. Value of Apparent Diffusion Coefficient Histogram Analysis in the Differential Diagnosis of Nasopharyngeal Lymphoma and Nasopharyngeal Carcinoma Based on Readout-Segmented Diffusion-Weighted Imaging. Front Oncol 2021; 11:632796. [PMID: 33777787 PMCID: PMC7996088 DOI: 10.3389/fonc.2021.632796] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2020] [Accepted: 01/29/2021] [Indexed: 11/13/2022] Open
Abstract
Background This study aims to explore the utility of whole-lesion apparent diffusion coefficient (ADC) histogram analysis for differentiating nasopharyngeal lymphoma (NPL) from nasopharyngeal carcinoma (NPC) following readout-segmented echo-planar diffusion-weighted imaging (RESOLVE sequence). Methods Thirty-eight patients with NPL and 62 patients with NPC, who received routine head-and-neck MRI and RESOLVE (b-value: 0 and 1,000 s/mm2) examinations, were retrospectively evaluated as derivation cohort (February 2015 to August 2018); another 23 patients were analyzed as validation cohort (September 2018 to December 2019). The RESOLVE data were obtained from the MAGNETOM Skyra 3T MR system (Siemens Healthcare, Erlangen, Germany). Fifteen parameters derived from the whole-lesion histogram analysis (ADCmean, variance, skewness, kurtosis, ADC1, ADC10, ADC20, ADC30, ADC40, ADC50, ADC60, ADC70, ADC80, ADC90, and ADC99) were calculated for each patient. Then, statistical analyses were performed between the two groups to determine the statistical significance of each histogram parameter. A receiver operating characteristic curve (ROC) analysis was conducted to assess the diagnostic performance of each histogram parameter for distinguishing NPL from NPC and further tested in the validation cohort; calibration of the selected parameter was tested with Hosmer-Lemeshow test. Results NPL exhibited significantly lower ADCmean, variance, ADC1, ADC10, ADC20, ADC30, ADC40, ADC50, ADC60, ADC70, ADC80, ADC90 and ADC99, when compared to NPC (all, P < 0.05), while no significant differences were found on skewness and kurtosis. Furthermore, ADC99 revealed the highest diagnostic efficiency, followed by ADC10 and ADC20. Optimal diagnostic performance (AUC = 0.790, sensitivity = 91.9%, and specificity = 63.2%) could be achieved when setting ADC99 = 1,485.0 × 10-6 mm2/s as the threshold value. The predictive performance was maintained in the validation cohort (AUC = 0.817, sensitivity = 94.6%, and specificity = 56.2%). Conclusion Whole-lesion ADC histograms based on RESOLVE are effective in differentiating NPC from NPL.
Collapse
Affiliation(s)
- Chengru Song
- Department of MRI, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Peng Cheng
- Department of radiotherapy, Henan Provincial People's Hospital, Zhengzhou, China
| | - Jingliang Cheng
- Department of MRI, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Yong Zhang
- Department of MRI, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Shanshan Xie
- Department of MRI, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| |
Collapse
|
39
|
Sanderink WBG, Teuwen J, Appelman L, Moy L, Heacock L, Weiland E, Karssemeijer N, Baltzer PAT, Sechopoulos I, Mann RM. Comparison of simultaneous multi-slice single-shot DWI to readout-segmented DWI for evaluation of breast lesions at 3T MRI. Eur J Radiol 2021; 138:109626. [PMID: 33711569 DOI: 10.1016/j.ejrad.2021.109626] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2020] [Revised: 02/15/2021] [Accepted: 03/01/2021] [Indexed: 01/09/2023]
Abstract
PURPOSE To compare diffusion-weighted imaging of the breast performed with a conventional readout-segmented echo-planar imaging (rs-EPI) sequence to when using a prototype simultaneous multi-slice single-shot EPI (SMS-ss-EPI) acquisition. METHOD From September 2017 to December 2018, 26 women with histologically proven breast cancer were scanned with the conventional rs-EPI and the SMS-ss-EPI at 3 T during the same imaging examination. Four breast radiologists (4-13 years of experience) independently scored both acquired series of 25 women (one case was used for training) for overall image quality (1: extremely poor to 9: excellent) and artifacts (1: very disturbing to 5: not present). All lesions (n = 52; 40 malignant, 12 benign) were also evaluated for visibility (1: not visible, 2: visible if location is given, 3: visible). In addition, lesion characteristics were rated, and a BI-RADS score was given. Results were analyzed using visual grading characteristics and the resulting area under the curve (AUCVGC), weighted kappa, McNemar test, and dependent-samples t-test when appropriate. RESULTS Overall, radiologists significantly preferred the image quality in rs-EPI over that of SMS-ss-EPI (AUCVGC: 0.698, P = 0.002). Infolding and ghosting, and distortion artifacts were significantly less apparent in the rs-EPI (AUCVGC: 0.660, P = 0.022 and AUCVGC: 0.700 P = 0.002, respectively). Lesions were, however, significantly better visible on the SMS-ss-EPI images (AUCVGC: 0.427, P = 0.016). Malignant lesions had significantly higher visibility with SMS-ss-EPI (P = 0.035). Sensitivity and specificity were comparable between both sequences (P = 0.760 and P = 0.549, respectively). CONCLUSIONS Despite the perceived lower image quality and the increased presence of artifacts in the SMS-ss-EPI sequence, malignant lesions are better visualized using this sequence.
Collapse
Affiliation(s)
- Wendelien B G Sanderink
- Medical Imaging, Radboud University Medical Centre, Geert Grooteplein Zuid 10, Nijmegen, 6525GA, the Netherlands.
| | - Jonas Teuwen
- Medical Imaging, Radboud University Medical Centre, Geert Grooteplein Zuid 10, Nijmegen, 6525GA, the Netherlands
| | - Linda Appelman
- Medical Imaging, Radboud University Medical Centre, Geert Grooteplein Zuid 10, Nijmegen, 6525GA, the Netherlands
| | - Linda Moy
- Department of Radiology, New York University Langone Medical Center, 660 First Avenue, 4(th) Floor, New York, NY, 10016, United States
| | - Laura Heacock
- Department of Radiology, New York University Langone Medical Center, 660 First Avenue, 4(th) Floor, New York, NY, 10016, United States
| | - Elisabeth Weiland
- MR Application Predevelopment, Siemens Healthcare, Allee am Roethelheimpark 2, Erlangen, 91052, Germany
| | - Nico Karssemeijer
- Medical Imaging, Radboud University Medical Centre, Geert Grooteplein Zuid 10, Nijmegen, 6525GA, the Netherlands
| | - Pascal A T Baltzer
- Department of Biomedical Imaging and Image-guided Therapy, Vienna General Hospital, Währinger Gürtel 18-20, Vienna, 1090, Austria
| | - Ioannis Sechopoulos
- Medical Imaging, Radboud University Medical Centre, Geert Grooteplein Zuid 10, Nijmegen, 6525GA, the Netherlands
| | - Ritse M Mann
- Medical Imaging, Radboud University Medical Centre, Geert Grooteplein Zuid 10, Nijmegen, 6525GA, the Netherlands
| |
Collapse
|
40
|
Hu Y, Ikeda DM, Pittman SM, Samarawickrama D, Guidon A, Rosenberg J, Chen ST, Okamoto S, Daniel BL, Hargreaves BA, Moran CJ. Multishot Diffusion-Weighted MRI of the Breast With Multiplexed Sensitivity Encoding (MUSE) and Shot Locally Low-Rank (Shot-LLR) Reconstructions. J Magn Reson Imaging 2021; 53:807-817. [PMID: 33067849 PMCID: PMC8084247 DOI: 10.1002/jmri.27383] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2020] [Revised: 09/13/2020] [Accepted: 09/17/2020] [Indexed: 12/24/2022] Open
Abstract
BACKGROUND Diffusion-weighted imaging (DWI) has shown promise to screen for breast cancer without a contrast injection, but image distortion and low spatial resolution limit standard single-shot DWI. Multishot DWI methods address these limitations but introduce shot-to-shot phase variations requiring correction during reconstruction. PURPOSE To investigate the performance of two multishot DWI reconstruction methods, multiplexed sensitivity encoding (MUSE) and shot locally low-rank (shot-LLR), compared to single-shot DWI in the breast. STUDY TYPE Prospective. POPULATION A total of 45 women who consented to have multishot DWI added to a clinically indicated breast MRI. FIELD STRENGTH/SEQUENCES Single-shot DWI reconstructed by parallel imaging, multishot DWI with four or eight shots reconstructed by MUSE and shot-LLR, 3D T2 -weighted imaging, and contrast-enhanced MRI at 3T. ASSESSMENT Three blinded observers scored images for 1) general image quality (perceived signal-to-noise ratio [SNR], ghosting, distortion), 2) lesion features (discernment and morphology), and 3) perceived resolution. Apparent diffusion coefficient (ADC) of the lesion was also measured and compared between methods. STATISTICAL TESTS Image quality features and perceived resolution were assessed with a mixed-effects logistic regression. Agreement among observers was estimated with a Krippendorf's alpha using linear weighting. Lesion feature ratings were visualized using histograms, and correlation coefficients of lesion ADC between different methods were calculated. RESULTS MUSE and shot-LLR images were rated to have significantly better perceived resolution (P < 0.001), higher SNR (P < 0.005), and a lower level of distortion (P < 0.05) with respect to single-shot DWI. Shot-LLR showed reduced ghosting artifacts with respect to both MUSE (P < 0.001) and single-shot DWI (P < 0.001). Eight-shot DWI had improved perceived SNR and perceived resolution with respect to four-shot DWI (P < 0.005). DATA CONCLUSION Multishot DWI enables increased resolution and improved image quality with respect to single-shot DWI in the breast. Shot-LLR reconstructs multishot DWI with minimal ghosting artifacts. The improvement of multishot DWI in image quality increases with an increased number of shots. LEVEL OF EVIDENCE 2 TECHNICAL EFFICACY STAGE: 2.
Collapse
Affiliation(s)
- Yuxin Hu
- Department of Radiology, Stanford University, Stanford, California, USA
- Department of Electrical Engineering, Stanford University, Stanford, California, USA
| | - Debra M. Ikeda
- Department of Radiology, Stanford University, Stanford, California, USA
| | - Sarah M. Pittman
- Department of Radiology, Stanford University, Stanford, California, USA
| | | | - Arnaud Guidon
- Global MR Application and Workflow, GE Healthcare, Boston, Massachusetts, USA
| | - Jarrett Rosenberg
- Department of Radiology, Stanford University, Stanford, California, USA
| | - Shu-tian Chen
- Department of Radiology, Stanford University, Stanford, California, USA
- Department of Diagnostic Radiology, Chang Gung Memorial Hospital, Chiayi, Taiwan
| | - Satoko Okamoto
- Department of Radiology, Stanford University, Stanford, California, USA
- Department of Radiology, Breast and Imaging Center, St. Marianna University School of Medicine, Kawasaki, Japan
| | - Bruce L. Daniel
- Department of Radiology, Stanford University, Stanford, California, USA
- Department of Bioengineering, Stanford University, Stanford, California, USA
| | - Brian A. Hargreaves
- Department of Radiology, Stanford University, Stanford, California, USA
- Department of Electrical Engineering, Stanford University, Stanford, California, USA
- Department of Bioengineering, Stanford University, Stanford, California, USA
| | | |
Collapse
|
41
|
Baxter GC, Patterson AJ, Woitek R, Allajbeu I, Graves MJ, Gilbert F. Improving the image quality of DWI in breast cancer: comparison of multi-shot DWI using multiplexed sensitivity encoding to conventional single-shot echo-planar imaging DWI. Br J Radiol 2021; 94:20200427. [PMID: 32903028 PMCID: PMC8011253 DOI: 10.1259/bjr.20200427] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
Objective: To compare diffusion-weighted images (DWI) acquired using single-shot echo-planar imaging (ss-EPI) and multiplexed sensitivity encoding (MUSE) in breast cancer. Methods 20 females with pathologically confirmed breast cancer (age 51 ± 12 years) were imaged with ss-EPI-DWI and MUSE-DWI. ADC, normalised ADC (nADC), blur and distortion metrics and qualitative image quality scores were compared. The Crété-Roffet and Mattes mutual information metrics were used to evaluate blurring and distortion, respectively. In a breast phantom, six permutations of MUSE-DWI with varying parallel acceleration factor and number of shots were compared. Differences in ADC and nADC were compared using the coefficient of variation in the phantom and a paired t-test in patients. Differences in blur, distortion and qualitative metrics were analysed using a Wilcoxon signed-rank test. Results: There was a low coefficient of variation (<2%) in ADC between ss-EPI-DWI and all MUSE-DWI permutations acquired using the phantom. 22 malignant and three benign lesions were identified in 20 patients. ADC values measured using MUSE were significantly lower compared to ss-EPI for malignant but not benign lesions (p < 0.001, p = 0.21). nADC values were not significantly different (p = 0.62, p = 0.28). Blurring and distortion improved with number of shots and acceleration factor, and significantly improved with MUSE in patients (p < 0.001, p = 0.002). Qualitatively, image quality improved using MUSE. Conclusion: MUSE improves the image quality of breast DWI compared to ss-EPI. Advances in knowledge: MUSE-DWI has superior image quality and reduced blurring and distortion compared to ss-EPI-DWI in breast cancer.
Collapse
Affiliation(s)
- Gabrielle C Baxter
- Department of Radiology, University of Cambridge, Cambridge, United Kingdom
| | - Andrew J Patterson
- Department of Radiology, Addenbrooke's Hospital, Cambridge, United Kingdom
| | - Ramona Woitek
- Department of Radiology, University of Cambridge, Cambridge, United Kingdom
| | - Iris Allajbeu
- Department of Radiology, University of Cambridge, Cambridge, United Kingdom
| | - Martin J Graves
- Department of Radiology, Addenbrooke's Hospital, Cambridge, United Kingdom
| | - Fiona Gilbert
- Department of Radiology, University of Cambridge, Cambridge, United Kingdom
| |
Collapse
|
42
|
Kim JJ, Kim JY. Fusion of high b-value diffusion-weighted and unenhanced T1-weighted images to diagnose invasive breast cancer: factors associated with false-negative results. Eur Radiol 2021; 31:4860-4871. [PMID: 33443601 DOI: 10.1007/s00330-020-07644-5] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2020] [Revised: 11/06/2020] [Accepted: 12/17/2020] [Indexed: 10/22/2022]
Abstract
OBJECTIVES We sought factors associated with false-negative results in the diagnosis of invasive breast cancer via non-contrast breast magnetic resonance imaging (MRI) using fused high b-value diffusion-weighted imaging (DWI) and unenhanced T1-weighted images (T1WI). METHODS Between 2018 and 2019, 316 consecutive women (mean age, 54.6 years) with invasive breast cancer who underwent preoperative breast MRI, including fused high b-value DWI and unenhanced T1WI, were retrospectively evaluated. Malignancy confidence ratings of the most suspicious breast lesions evident on fused DWI were derived by two radiologists using a 6-point Likert-type scale. Both clinicopathological and imaging features were analyzed. Multivariate regression analysis was performed to identify factors associated with false-negative DWI results in the diagnosis of invasive breast cancer. RESULTS Of the 316 breast cancers, fused DWI yielded 289 (91.5%) true-positive and 27 (8.5%) false-negative results. Multivariate analysis showed that small tumor size (≤ 1 cm) (odds ratio [OR], 5.95; 95% confidence interval [CI], 2.11, 16.81; p = 0.001), presence of calcifications in the tumor (OR, 3.41; 95% CI, 1.27, 9.15; p = 0.015), and a moderate/marked background diffusion signal (ORs, 4.23 and 19.18; 95% CI, 1.31, 13.67 and 6.51, 56.46; p = 0.016 and p < 0.001, respectively) were significantly associated with false-negative results. In subgroup analysis of 141 screening-detected cancers, a marked background diffusion signal (OR, 7.94; 95% CI, 2.30, 27.35; p = 0.001) remained significantly associated with false-negative results in the multivariate analysis. CONCLUSIONS In addition to histopathological features, a higher background diffusion signal was associated with false-negative results in the diagnosis of invasive breast cancer via non-contrast MRI using fused high b-value DWI and unenhanced T1WI. KEY POINTS • Subcentimeter tumors and presence of calcifications in the tumor are associated with false-negative diffusion-weighted imaging results in the diagnosis of invasive breast cancer. • A higher degree of background diffusion signal may lead to false-negative interpretation of diffusion-weighted imaging in patients with invasive breast cancer.
Collapse
Affiliation(s)
- Jin Joo Kim
- Department of Radiology, Medical Research Institute, Pusan National University Hospital, Pusan National University School of Medicine, 1-10, Ami-Dong, Seo-gu, Busan, 602-739, Republic of Korea
| | - Jin You Kim
- Department of Radiology, Medical Research Institute, Pusan National University Hospital, Pusan National University School of Medicine, 1-10, Ami-Dong, Seo-gu, Busan, 602-739, Republic of Korea.
| |
Collapse
|
43
|
Whisenant JG, Romanoff J, Rahbar H, Kitsch AE, Harvey SM, Moy L, DeMartini WB, Dogan BE, Yang WT, Wang LC, Joe BN, Wilmes LJ, Hylton NM, Oh KY, Tudorica LA, Neal CH, Malyarenko DI, McDonald ES, Comstock CE, Yankeelov TE, Chenevert TL, Partridge SC. Factors Affecting Image Quality and Lesion Evaluability in Breast Diffusion-weighted MRI: Observations from the ECOG-ACRIN Cancer Research Group Multisite Trial (A6702). JOURNAL OF BREAST IMAGING 2021; 3:44-56. [PMID: 33543122 PMCID: PMC7835633 DOI: 10.1093/jbi/wbaa103] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2020] [Indexed: 12/27/2022]
Abstract
OBJECTIVE The A6702 multisite trial confirmed that apparent diffusion coefficient (ADC) measures can improve breast MRI accuracy and reduce unnecessary biopsies, but also found that technical issues rendered many lesions non-evaluable on diffusion-weighted imaging (DWI). This secondary analysis investigated factors affecting lesion evaluability and impact on diagnostic performance. METHODS The A6702 protocol was IRB-approved at 10 institutions; participants provided informed consent. In total, 103 women with 142 MRI-detected breast lesions (BI-RADS assessment category 3, 4, or 5) completed the study. DWI was acquired at 1.5T and 3T using a four b-value, echo-planar imaging sequence. Scans were reviewed for multiple quality factors (artifacts, signal-to-noise, misregistration, and fat suppression); lesions were considered non-evaluable if there was low confidence in ADC measurement. Associations of lesion evaluability with imaging and lesion characteristics were determined. Areas under the receiver operating characteristic curves (AUCs) were compared using bootstrapping. RESULTS Thirty percent (42/142) of lesions were non-evaluable on DWI; 23% (32/142) with image quality issues, 7% (10/142) with conspicuity and/or localization issues. Misregistration was the only factor associated with non-evaluability (P = 0.001). Smaller (≤10 mm) lesions were more commonly non-evaluable than larger lesions (p <0.03), though not significant after multiplicity correction. The AUC for differentiating benign and malignant lesions increased after excluding non-evaluable lesions, from 0.61 (95% CI: 0.50-0.71) to 0.75 (95% CI: 0.65-0.84). CONCLUSION Image quality remains a technical challenge in breast DWI, particularly for smaller lesions. Protocol optimization and advanced acquisition and post-processing techniques would help to improve clinical utility.
Collapse
Affiliation(s)
- Jennifer G Whisenant
- Vanderbilt University Medical Center, Department of Medicine, Nashville, TN
- Vanderbilt-Ingram Cancer Center, Nashville, TN
| | - Justin Romanoff
- Brown University, Center for Statistical Sciences, Providence, RI
| | - Habib Rahbar
- University of Washington, Department of Radiology, Seattle, WA
| | - Averi E Kitsch
- University of Washington, Department of Radiology, Seattle, WA
| | - Sara M Harvey
- Vanderbilt University Medical Center, Department of Radiology and Radiological Sciences, Nashville, TN
| | - Linda Moy
- New York University School of Medicine, Department of Radiology, New York, NY
| | - Wendy B DeMartini
- Stanford University School of Medicine, Department of Radiology, Stanford, CA
| | - Basak E Dogan
- University of Texas Southwestern Medical Center, Department of Diagnostic Radiology, Dallas, TX
| | - Wei T Yang
- MD Anderson Cancer Center, Department of Breast Imaging, Houston, TX
| | - Lilian C Wang
- Northwestern University Feinberg School of Medicine, Department of Radiology, Chicago, IL
| | - Bonnie N Joe
- University of California San Francisco School of Medicine, Department of Radiology and Biomedical Engineering, San Francisco, CA
| | - Lisa J Wilmes
- University of California San Francisco School of Medicine, Department of Radiology and Biomedical Engineering, San Francisco, CA
| | - Nola M Hylton
- University of California San Francisco School of Medicine, Department of Radiology and Biomedical Engineering, San Francisco, CA
| | - Karen Y Oh
- Oregon Health and Science University, Department of Radiology, Portland, OR
| | | | - Colleen H Neal
- University of Michigan, Department of Radiology/MRI, Ann Arbor, MI
| | | | - Elizabeth S McDonald
- University of Pennsylvania Perelman School of Medicine, Department of Radiology, Philadelphia, PA
| | | | - Thomas E Yankeelov
- University of Texas Austin, Department of Biomedical Engineering, Austin, TX
| | | | | |
Collapse
|
44
|
Moran CJ, Cheng JY, Sandino CM, Carl M, Alley MT, Rosenberg J, Daniel BL, Pittman SM, Rosen EL, Hargreaves BA. Diffusion-weighted double-echo steady-state with a three-dimensional cones trajectory for non-contrast-enhanced breast MRI. J Magn Reson Imaging 2020; 53:1594-1605. [PMID: 33382171 DOI: 10.1002/jmri.27492] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2020] [Revised: 12/08/2020] [Accepted: 12/10/2020] [Indexed: 12/30/2022] Open
Abstract
The image quality limitations of echo-planar diffusion-weighted imaging (DWI) are an obstacle to its widespread adoption in the breast. Steady-state DWI is an alternative DWI method with more robust image quality but its contrast for imaging breast cancer is not well-understood. The aim of this study was to develop and evaluate diffusion-weighted double-echo steady-state imaging with a three-dimensional cones trajectory (DW-DESS-Cones) as an alternative to conventional DWI for non-contrast-enhanced MRI in the breast. This prospective study included 28 women undergoing clinically indicated breast MRI and six asymptomatic volunteers. In vivo studies were performed at 3 T and included DW-DESS-Cones, DW-DESS-Cartesian, DWI, and CE-MRI acquisitions. Phantom experiments (diffusion phantom, High Precision Devices) and simulations were performed to establish framework for contrast of DW-DESS-Cones in comparison to DWI in the breast. Motion artifacts of DW-DESS-Cones were measured with artifact-to-noise ratio in volunteers and patients. Lesion-to-fibroglandular tissue signal ratios were measured, lesions were categorized as hyperintense or hypointense, and an image quality observer study was performed in DW-DESS-Cones and DWI in patients. Effect of DW-DESS-Cones method on motion artifacts was tested by mixed-effects generalized linear model. Effect of DW-DESS-Cones on signal in phantom was tested by quadratic regression. Correlation was calculated between DW-DESS-Cones and DWI lesion-to-fibroglandular tissue signal ratios. Inter-observer agreement was assessed with Gwet's AC. Simulations predicted hyperintensity of lesions with DW-DESS-Cones but at a 3% to 67% lower degree than with DWI. Motion artifacts were reduced with DW-DESS-Cones versus DW-DESS-Cartesian (p < 0.05). Lesion-to-fibroglandular tissue signal ratios were not correlated between DW-DESS-Cones and DWI (r = 0.25, p = 0.38). Concordant hyperintensity/hypointensity was observed between DW-DESS-Cones and DWI in 11/14 lesions. DW-DESS-Cones improved sharpness, distortion, and overall image quality versus DWI. DW-DESS-Cones may be able to eliminate motion artifacts in the breast allowing for investigation of higher degrees of steady-state diffusion weighting. Malignant breast lesions in DW-DESS-Cones demonstrated hyperintensity with respect to surrounding tissue without an injection of contrast. LEVEL OF EVIDENCE: 2. TECHNICAL EFFICACY STAGE: 1.
Collapse
Affiliation(s)
- Catherine J Moran
- Department of Radiology, Stanford University, Stanford, California, USA
| | - Joseph Y Cheng
- Department of Electrical Engineering, Stanford University, Stanford, California, USA
| | - Christopher M Sandino
- Department of Electrical Engineering, Stanford University, Stanford, California, USA
| | - Michael Carl
- Global MR Application and Workflow, GE Healthcare, San Diego, California, USA
| | - Marcus T Alley
- Department of Radiology, Stanford University, Stanford, California, USA
| | - Jarrett Rosenberg
- Department of Radiology, Stanford University, Stanford, California, USA
| | - Bruce L Daniel
- Department of Radiology, Stanford University, Stanford, California, USA
| | - Sarah M Pittman
- Department of Radiology, Stanford University, Stanford, California, USA
| | - Eric L Rosen
- Department of Radiology, Stanford University, Stanford, California, USA
| | - Brian A Hargreaves
- Department of Radiology, Stanford University, Stanford, California, USA.,Department of Electrical Engineering, Stanford University, Stanford, California, USA
| |
Collapse
|
45
|
Song SE, Woo OH, Cho KR, Seo BK, Son YH, Grimm R, Liu W, Moon WK. Simultaneous Multislice Readout-Segmented Echo Planar Imaging for Diffusion-Weighted MRI in Patients With Invasive Breast Cancers. J Magn Reson Imaging 2020; 53:1108-1115. [PMID: 33170536 DOI: 10.1002/jmri.27433] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2020] [Revised: 10/23/2020] [Accepted: 10/23/2020] [Indexed: 11/08/2022] Open
Abstract
BACKGROUND In diffusion-weighted imaging (DWI) of breast MRI, simultaneous multislice acceleration techniques can be used for readout-segmented echo planar imaging (rs-EPI) to shorten the scan time. PURPOSE To compare the image quality, apparent diffusion coefficient (ADC) value, and scan time of rs-EPI and simultaneous multislice rs-EPI (SMS rs-EPI) sequences. STUDY TYPE Retrospective. SUBJECTS In all, 134 consecutive women (mean age: 55.3 years) with invasive breast cancer who underwent preoperative MRI. FIELD STRENGTH/ SEQUENCES 3.0T; rs-EPI sequence, prototypic SMS rs-EPI sequence and dynamic contrast-enhanced MRI (DCE-MRI) sequence ASSESSMENT: For quantitative comparison, two radiologists independently measured the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), lesion contrast, and apparent diffusion coefficient (ADC). For qualitative comparison, image quality, lesion conspicuity, and reader preference were assessed with a reference of DCE-MRI. STATISTICAL TESTS Paired t-tests and Mann-Whitney tests were used. RESULTS For SNR and CNR, there were no differences between the sequences (P = 0.342 and 0.665 for reader 1; P = 0.606 and P = 0.116 for reader 2). Lesion contrast of SMS rs-EPI was higher than that of rs-EPI (P < 0.05 for both reader 1 and reader 2). Mean tumor ADC was similar in rs-EPI and SMS rs-EPI sequences (0.98 ± 0.22 vs. 1.00 ± 0.22; P = 0.291 for reader 1, 0.98 ± 0.21 vs. 1.00 ± 0.22; P = 0.418 for reader 2). Regarding qualitative comparison, image quality and lesion conspicuity were higher in SMS rs-EPI than in rs-EPI (both P < 0.05 for both readers). The two readers regarded SMS rs-EPI as superior or equal to rs-EPI in over 90% of cases. The acquisition time was 4:30 minutes for rs-EPI and 2:31 minutes for SMS rs-EPI. DATA CONCLUSION The SMS rs-EPI sequence resulted in a similar ADC value and better image quality than the rs-EPI sequence in a 44.1% reduced scan time. LEVEL OF EVIDENCE 4 TECHNICAL EFFICACY: 3.
Collapse
Affiliation(s)
- Sung Eun Song
- Department of Radiology, Korea University Anam Hospital, Korea University College of Medicine, Seoul, South Korea
| | - Ok Hee Woo
- Department of Radiology, Korea University Ansan Hospital, Korea University College of Medicine, Ansan, South Korea
| | - Kyu Ran Cho
- Department of Radiology, Korea University Anam Hospital, Korea University College of Medicine, Seoul, South Korea
| | - Bo Kyoung Seo
- Department of Radiology, Korea University Guro Hospital, Korea University College of Medicine, Seoul, South Korea
| | | | | | - Wei Liu
- Siemens Shenzhen Magnetic Resonance Ltd, Shenzhen, China
| | - Woo Kyung Moon
- Department of Radiology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, South Korea
| |
Collapse
|
46
|
Hu Y, Zhan C, Yang Z, Zhang X, Zhang H, Liu W, Xia L, Ai T. Accelerating acquisition of readout-segmented echo planar imaging with a simultaneous multi-slice (SMS) technique for diagnosing breast lesions. Eur Radiol 2020; 31:2667-2676. [PMID: 33146797 DOI: 10.1007/s00330-020-07393-5] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2020] [Revised: 09/09/2020] [Accepted: 10/08/2020] [Indexed: 10/23/2022]
Abstract
OBJECTIVES To investigate the feasibility and effectiveness of SMS rs-EPI for evaluating breast lesions. METHODS This prospective study was approved by IRB. Ninety-six patients had 102 histopathologically verified lesions (80 malignant and 22 benign) that were evaluated. Conventional rs-EPI and SMS rs-EPI data were acquired on a 3T scanner. Mean kurtosis (MK), mean diffusion (MD), and apparent diffusion coefficient (ADC) values were quantitatively calculated for each lesion on both sequences. Images were qualitatively and quantitatively analyzed with respect to image sharpness, geometric distortion, lesion conspicuity, anatomic structure, overall image quality, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). Student's t test, Pearson correlation, receiver operating characteristic curve, Wilcoxon rank sum test, and paired-sample t tests were used for statistical analysis. RESULTS Compared to conventional rs-EPI, the acquisition time of SMS rs-EPI was markedly reduced (2:17 min vs 4:27 min). Pearson's correlations showed excellent linear relationships for each parameter between conventional rs-EPI and SMS rs-EPI (MK, r = 0.908; MD, r = 0.938; and ADC, r = 0.975; p < 0.01 for all). Furthermore, SMS rs-EPI had similar diagnostic performance compared with conventional rs-EPI. SMS rs-EPI had comparable visual image quality as conventional rs-EPI, with excellent inter-reader reliability (ICC = 0.851-0.940). No differences existed between conventional rs-EPI and SMS rs-EPI for either SNR or CNR (p > 0.05). CONCLUSIONS Applying the SMS technique can significantly reduce the acquisition time and produce similar diagnostic accuracy while generating comparable image quality as the conventional rs-EPI. KEY POINTS • SMS rs-EPI reduces scan time from 4:27 min to 2:17 min compared with conventional rs-EPI. • SMS rs-EPI has a comparable diagnostic performance to conventional rs-EPI in the differentiation between malignant and benign breast lesions. • SMS rs-EPI demonstrates comparable image quality to conventional rs-EPI with shorter scan time.
Collapse
Affiliation(s)
- Yiqi Hu
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, Hubei, China
| | - Chenao Zhan
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, Hubei, China
| | - Zhenlu Yang
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, Hubei, China
| | - Xiaoyong Zhang
- MR Collaborations, Siemens Healthcare, Shenzhen, 518000, China
| | - Huiting Zhang
- MR Scientific Marketing, Siemens Healthcare, Wuhan, 430030, Hubei, China
| | - Wei Liu
- Siemens Shenzhen Magnetic Resonance, Shenzhen, 518000, China
| | - Liming Xia
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, Hubei, China
| | - Tao Ai
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, Hubei, China.
| |
Collapse
|
47
|
Ma G, Xu XQ, Zhu LN, Jiang JS, Su GY, Hu H, Bu SS, Wu FY. Intravoxel Incoherent Motion Magnetic Resonance Imaging for Assessing Parotid Gland Tumors: Correlation and Comparison with Arterial Spin Labeling Imaging. Korean J Radiol 2020; 22:243-252. [PMID: 32932565 PMCID: PMC7817638 DOI: 10.3348/kjr.2020.0290] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2020] [Revised: 04/14/2020] [Accepted: 06/06/2020] [Indexed: 12/26/2022] Open
Abstract
Objective To compare and correlate the findings of intravoxel incoherent motion (IVIM) magnetic resonance (MR) imaging and arterial spin labeling (ASL) imaging in characterizing parotid gland tumors. Materials and Methods We retrospectively reviewed 56 patients with parotid gland tumors evaluated by MR imaging. The true diffusion coefficient (D), pseudo-diffusion coefficient (D*), and fraction of perfusion (f) values of IVIM imaging and tumor-to-parotid gland signal intensity ratio (SIR) on ASL imaging were calculated. Spearman rank correlation coefficient, chi-squared, Mann-Whitney U, and Kruskal-Wallis tests with the post-hoc Dunn-Bonferroni method and receiver operating characteristic curve assessments were used for statistical analysis. Results Malignant parotid gland tumors showed significantly lower D than benign tumors (p = 0.019). Within subgroup analyses, pleomorphic adenomas (PAs) showed significantly higher D than malignant tumors (MTs) and Warthin's tumors (WTs) (p < 0.001). The D* of WTs was significantly higher than that of PAs (p = 0.031). The f and SIR on ASL imaging of WTs were significantly higher than those of MTs and PAs (p < 0.05). Significantly positive correlation was found between SIR on ASL imaging and f (r = 0.446, p = 0.001). In comparison with f, SIR on ASL imaging showed a higher area under curve (0.853 vs. 0.891) in discriminating MTs from WTs, although the difference was not significant (p = 0.720). Conclusion IVIM and ASL imaging could help differentiate parotid gland tumors. SIR on ASL imaging showed a significantly positive correlation with f. ASL imaging might hold potential to improve the ability to discriminate MTs from WTs.
Collapse
Affiliation(s)
- Gao Ma
- Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China
| | - Xiao Quan Xu
- Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China
| | - Liu Ning Zhu
- Department of Stomatology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China
| | - Jia Suo Jiang
- Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China
| | - Guo Yi Su
- Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China
| | - Hao Hu
- Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China
| | - Shou Shan Bu
- Department of Stomatology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China
| | - Fei Yun Wu
- Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China.
| |
Collapse
|
48
|
Diffusion-Weighted MRI to Assess Sacroiliitis: Improved Image Quality and Diagnostic Performance of Readout-Segmented Echo-Planar Imaging (EPI) Over Conventional Single-Shot EPI. AJR Am J Roentgenol 2020; 217:450-459. [PMID: 32903053 DOI: 10.2214/ajr.20.23953] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
BACKGROUND. DWI using single-shot echo-planar imaging (ss-EPI) is prone to artifacts, signal-intensity dropout, and T2* blurring. Readout-segmented echo-planar imaging (rs-EPI) may improve image quality in DWI of the sacroiliac joints. OBJECTIVE. The purposes of this study were, first, to qualitatively and quantitatively compare image quality between ss-EPI and rs-EPI DWI of the sacroiliac joints; and, second, to evaluate whether ADC values derived from ss-EPI and rs-EPI can differentiate disease activity in patients with axial spondyloarthritis (axSpA). METHODS. This retrospective study included 75 patients who underwent ss-EPI and rs-EPI DWI of the sacroiliac joints. Patients were classified into axSpA (n = 50) and no-ax-SpA (n = 25) groups on the basis of Assessment of SpondyloArthritis International Society (ASAS) criteria. Patients in the axSpA group were assigned to one of four disease activity states using the Ankylosing Spondylitis Disease Activity Score-C-reactive protein (ASDAS-CRP). Two radiologists independently assessed qualitative (overall image quality and diagnostic confidence) and quantitative (ADC, signal-to-noise ratio [SNR], and contrast-to-noise ratio [CNR]) imaging parameters. RESULTS. Readout-segmented EPI provided significantly better overall image quality, diagnostic confidence, SNR, and CNR than ss-EPI (both readers, p < .001). In patients with axSpA, the correlation coefficients (r) of ADC values and ASDAS-CRP values were 0.456 and 0.458 for ss-EPI and 0.537 and 0.558 for rs-EPI. ADCs showed progressive increases with increasing activity state for both sequences, although these increases were more substantial for rs-EPI than for ss-EPI. Across readers, median ADCs for ss-EPI were 0.243 and 0.234 × 10-3 mm2/s for inactive disease, 0.411 and 0.412 × 10-3 mm2/s for moderate disease activity, 0.499 and 0.447 × 10-3 mm2/s for high activity, and 0.671 and 0.575 × 10-3 mm2/s for very high activity (reader 1, p = .011; reader 2, p = .010). Across readers, ADCs for rs-EPI were 0.236 and 0.236 × 10-3 mm2/s for inactive disease, 0.483 and 0.477 × 10-3 mm2/s for moderate disease activity, 0.727 and 0.692 × 10-3 mm2/s for high activity, and 0.902 and 0.803 × 10-3 mm2/s for very high activity (reader 1, p = .002; reader 2, p = .001). ADC values for ss-EPI were significantly different only between the inactive and very high disease activity groups (p < .0083, Bonferroni-corrected threshold). ADC values for rs-EPI were significantly different between the inactive and high, inactive and very high, as well as the moderate and very high disease activity groups (p < .0083, Bonferroni-corrected threshold). CONCLUSION. Readout-segmented EPI significantly improves the image quality of DWI in imaging the sacroiliac joints. In patients with axSpA, activity states are better differentiated by rs-EPI than by ss-EPI. CLINICAL IMPACT. Readout-segmented EPI is a more robust tool than ss-EPI for imaging of axSpA and should be included in routine clinical protocols for MRI of the sacroiliac joints.
Collapse
|
49
|
McKay JA, Church AL, Rubin N, Emory TH, Hoven NF, Kuehn-Hajder JE, Nelson MT, Ramanna S, Auerbach EJ, Moeller S, Bolan PJ. A Comparison of Methods for High-Spatial-Resolution Diffusion-weighted Imaging in Breast MRI. Radiology 2020; 297:304-312. [PMID: 32840468 DOI: 10.1148/radiol.2020200221] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Background Diffusion-weighted imaging (DWI) shows promise in detecting and monitoring breast cancer, but standard spin-echo (SE) echo-planar DWI methods often have poor image quality and low spatial resolution. Proposed alternatives include readout-segmented (RS) echo-planar imaging and axially reformatted (AR)-simultaneous multislice (SMS) imaging. Purpose To compare the resolution and image quality of standard SE echo-planar imaging DWI with two high-spatial-resolution alternatives, RS echo-planar and AR-SMS imaging, for breast imaging. Materials and Methods In a prospective study (2016-2018), three 5-minute DWI protocols were acquired at 3.0 T, including standard SE echo-planar imaging, RS echo-planar imaging with five segments, and AR-SMS imaging with four times slice acceleration. Participants were women undergoing breast MRI either as part of a treatment response clinical trial or undergoing breast MRI for screening or suspected cancer. A commercial breast phantom was imaged for resolution comparison. Three breast radiologists reviewed images in random order, including clinical images indicating the lesion, images with b value of 800 sec/mm2, and apparent diffusion coefficient (ADC) maps from the three randomly labeled DWI methods. Readers measured the longest dimension and lesion-average ADC on three DWI methods, reported measurement confidence, and rated or ranked the quality of each image. The scores were fit to a linear mixed-effects model with intercepts for reader and subject. Results The smallest feature (1 mm) was only detectible in a phantom on images from AR-SMS DWI. Thirty lesions from 28 women (mean age, 50 years ± 13 [standard deviation]) were evaluated. On the five-point Likert scale for image quality, AR-SMS imaging scored 1.31 points higher than SE echo-planar imaging and 0.74 points higher than RS echo-planar imaging, whereas RS echo-planar imaging scored 0.57 points higher than SE echo-planar imaging (all P < .001). Conclusion The axially reformatted simultaneous multislice protocol was rated highest for image quality, followed by the readout-segmented echo-planar imaging protocol. Both were rated higher than the standard spin-echo echo-planar imaging. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Partridge in this issue.
Collapse
Affiliation(s)
- Jessica A McKay
- From the Department of Biomedical Engineering (J.A.M., P.J.B.), Center for Magnetic Resonance Research (J.A.M., S.R., E.J.A., S.M., P.J.B.), Department of Radiology (A.L.C., T.H.E., N.F.H., J.E.K.H., M.T.N., S.R., E.J.A., S.M., P.J.B.), and Biostatistics Core, Masonic Cancer Center (N.R.), University of Minnesota, Center for Magnetic Resonance Research, 2021 6th St SE, Minneapolis, MN 55455
| | - An L Church
- From the Department of Biomedical Engineering (J.A.M., P.J.B.), Center for Magnetic Resonance Research (J.A.M., S.R., E.J.A., S.M., P.J.B.), Department of Radiology (A.L.C., T.H.E., N.F.H., J.E.K.H., M.T.N., S.R., E.J.A., S.M., P.J.B.), and Biostatistics Core, Masonic Cancer Center (N.R.), University of Minnesota, Center for Magnetic Resonance Research, 2021 6th St SE, Minneapolis, MN 55455
| | - Nathan Rubin
- From the Department of Biomedical Engineering (J.A.M., P.J.B.), Center for Magnetic Resonance Research (J.A.M., S.R., E.J.A., S.M., P.J.B.), Department of Radiology (A.L.C., T.H.E., N.F.H., J.E.K.H., M.T.N., S.R., E.J.A., S.M., P.J.B.), and Biostatistics Core, Masonic Cancer Center (N.R.), University of Minnesota, Center for Magnetic Resonance Research, 2021 6th St SE, Minneapolis, MN 55455
| | - Tim H Emory
- From the Department of Biomedical Engineering (J.A.M., P.J.B.), Center for Magnetic Resonance Research (J.A.M., S.R., E.J.A., S.M., P.J.B.), Department of Radiology (A.L.C., T.H.E., N.F.H., J.E.K.H., M.T.N., S.R., E.J.A., S.M., P.J.B.), and Biostatistics Core, Masonic Cancer Center (N.R.), University of Minnesota, Center for Magnetic Resonance Research, 2021 6th St SE, Minneapolis, MN 55455
| | - Noelle F Hoven
- From the Department of Biomedical Engineering (J.A.M., P.J.B.), Center for Magnetic Resonance Research (J.A.M., S.R., E.J.A., S.M., P.J.B.), Department of Radiology (A.L.C., T.H.E., N.F.H., J.E.K.H., M.T.N., S.R., E.J.A., S.M., P.J.B.), and Biostatistics Core, Masonic Cancer Center (N.R.), University of Minnesota, Center for Magnetic Resonance Research, 2021 6th St SE, Minneapolis, MN 55455
| | - Jessica E Kuehn-Hajder
- From the Department of Biomedical Engineering (J.A.M., P.J.B.), Center for Magnetic Resonance Research (J.A.M., S.R., E.J.A., S.M., P.J.B.), Department of Radiology (A.L.C., T.H.E., N.F.H., J.E.K.H., M.T.N., S.R., E.J.A., S.M., P.J.B.), and Biostatistics Core, Masonic Cancer Center (N.R.), University of Minnesota, Center for Magnetic Resonance Research, 2021 6th St SE, Minneapolis, MN 55455
| | - Michael T Nelson
- From the Department of Biomedical Engineering (J.A.M., P.J.B.), Center for Magnetic Resonance Research (J.A.M., S.R., E.J.A., S.M., P.J.B.), Department of Radiology (A.L.C., T.H.E., N.F.H., J.E.K.H., M.T.N., S.R., E.J.A., S.M., P.J.B.), and Biostatistics Core, Masonic Cancer Center (N.R.), University of Minnesota, Center for Magnetic Resonance Research, 2021 6th St SE, Minneapolis, MN 55455
| | - Sudhir Ramanna
- From the Department of Biomedical Engineering (J.A.M., P.J.B.), Center for Magnetic Resonance Research (J.A.M., S.R., E.J.A., S.M., P.J.B.), Department of Radiology (A.L.C., T.H.E., N.F.H., J.E.K.H., M.T.N., S.R., E.J.A., S.M., P.J.B.), and Biostatistics Core, Masonic Cancer Center (N.R.), University of Minnesota, Center for Magnetic Resonance Research, 2021 6th St SE, Minneapolis, MN 55455
| | - Edward J Auerbach
- From the Department of Biomedical Engineering (J.A.M., P.J.B.), Center for Magnetic Resonance Research (J.A.M., S.R., E.J.A., S.M., P.J.B.), Department of Radiology (A.L.C., T.H.E., N.F.H., J.E.K.H., M.T.N., S.R., E.J.A., S.M., P.J.B.), and Biostatistics Core, Masonic Cancer Center (N.R.), University of Minnesota, Center for Magnetic Resonance Research, 2021 6th St SE, Minneapolis, MN 55455
| | - Steen Moeller
- From the Department of Biomedical Engineering (J.A.M., P.J.B.), Center for Magnetic Resonance Research (J.A.M., S.R., E.J.A., S.M., P.J.B.), Department of Radiology (A.L.C., T.H.E., N.F.H., J.E.K.H., M.T.N., S.R., E.J.A., S.M., P.J.B.), and Biostatistics Core, Masonic Cancer Center (N.R.), University of Minnesota, Center for Magnetic Resonance Research, 2021 6th St SE, Minneapolis, MN 55455
| | - Patrick J Bolan
- From the Department of Biomedical Engineering (J.A.M., P.J.B.), Center for Magnetic Resonance Research (J.A.M., S.R., E.J.A., S.M., P.J.B.), Department of Radiology (A.L.C., T.H.E., N.F.H., J.E.K.H., M.T.N., S.R., E.J.A., S.M., P.J.B.), and Biostatistics Core, Masonic Cancer Center (N.R.), University of Minnesota, Center for Magnetic Resonance Research, 2021 6th St SE, Minneapolis, MN 55455
| |
Collapse
|
50
|
Jiang JS, Zhu LN, Wu Q, Sun Y, Liu W, Xu XQ, Wu FY. Feasibility study of using simultaneous multi-slice RESOLVE diffusion weighted imaging to assess parotid gland tumors: comparison with conventional RESOLVE diffusion weighted imaging. BMC Med Imaging 2020; 20:93. [PMID: 32762734 PMCID: PMC7412638 DOI: 10.1186/s12880-020-00492-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2020] [Accepted: 07/29/2020] [Indexed: 11/17/2022] Open
Abstract
Background To evaluate the feasibility of using simultaneous multi-slice (SMS) readout segmentation of long variable echo-trains (RESOLVE) diffusion-weighted imaging (DWI) to assess parotid gland tumors, compared with conventional RESOLVE DWI. Methods From September 2018 to December 2018, 20 consecutive patients with parotid tumors who underwent MRI scan for pre-surgery evaluation were enrolled. SMS-RESOLVE DWI and conventional RESOLVE DWI were scanned with matched imaging parameters, respectively. The scan time of two DWI sequences was recorded. Qualitative (anatomical structure differentiation, lesion display, artifact, and overall image quality) and quantitative (apparent diffusion coefficient, ADC; ratio of signal-to-noise ratio, SNR ratio; ratio of contrast-to-noise ratio, CNR ratio) assessments of image quality were performed, and compared between SMS-RESOLVE DWI and conventional RESOLVE DWI by using Paired t-test. Two-sided P value less than 0.05 indicated significant difference. Results The scan time was 3 min and 41 s for SMS-RESOLVE DWI, and 5 min and 46 s for conventional RESOLVE DWI. SMS-RESOLVE DWI produced similar qualitative image quality with RESOLVE DWI (anatomical structure differentiation, P = 0.164; lesion display, P = 0.193; artifact, P = 0.330; overall image quality, P = 0.083). Meanwhile, there were no significant difference on ADCLesion (P = 0.298), ADCMasseter (P = 0.122), SNR ratio (P = 0.584) and CNR ratio (P = 0.217) between two DWI sequences. Conclusion Compared with conventional RESOLVE DWI, SMS-RESOLVE DWI could provide comparable image quality using markedly reduced scan time. SMS could increase the clinical usability of RESOLVE technique for DWI of parotid gland.
Collapse
Affiliation(s)
- Jia-Suo Jiang
- Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, No. 300, Guangzhou Rd, Nanjing, China
| | - Liu-Ning Zhu
- Department of Stomatology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China
| | - Qian Wu
- Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, No. 300, Guangzhou Rd, Nanjing, China
| | - Yi Sun
- MR Collaboration, Siemens Healthcare Ltd., Shanghai, China
| | - Wei Liu
- Siemens Shenzhen Magnetic Resonance Ltd., Shenzhen, China
| | - Xiao-Quan Xu
- Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, No. 300, Guangzhou Rd, Nanjing, China.
| | - Fei-Yun Wu
- Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, No. 300, Guangzhou Rd, Nanjing, China.
| |
Collapse
|