1
|
Tharwat S, Saleh M, Elrefaey R, Nassar MK, Nassar MK. Clinical and Ultrasonographic Characteristics of the Achilles Tendon in Hemodialysis Patients. MEDICINA (KAUNAS, LITHUANIA) 2023; 59:2181. [PMID: 38138284 PMCID: PMC10744597 DOI: 10.3390/medicina59122181] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/02/2023] [Revised: 12/05/2023] [Accepted: 12/12/2023] [Indexed: 12/24/2023]
Abstract
Background and Objectives: The early recognition of tendon alterations in chronic hemodialysis (HD) patients, an awareness of the factors that influence the condition, and active intervention have considerable clinical relevance. The aim of this study was to investigate the musculoskeletal ultrasound (MSUS) features of the Achilles tendon in chronic HD patients and determine the factors associated with tendon abnormalities. Materials and Methods: This study was conducted on 46 HD patients and 24 sex- and age-matched controls. All participants were evaluated clinically for any signs of Achilles tendon abnormalities. Then, the Achilles tendon was scanned bilaterally using MSUS. Results: Among the 92 Achilles tendons in the HD patients, there was tenderness and swelling of only two (2.2%). Regarding MSUS features, there were statistically significant higher thicknesses in the proximal end (p < 0.001), midpoint (p < 0.001), and distal end (p < 0.001) of the Achilles tendons in the HD patients when compared with the healthy controls. Tendinosis was found in 12 (13%) of the HD patients' Achilles tendons, which was statistically significant in comparison to the healthy controls (p = 0.008). There were statistically significant higher scores of structural abnormalities (p = 0.005), bone erosions (p = 0.017), and calcifications (p = 0.015) in the HD patients when compared to the healthy controls. According to the results of a univariate regression analysis, age and male gender were predictive for US abnormalities in HD patients (p = 0.002 and 0.025, respectively). Conclusions: The Achilles tendon in subjects on chronic HD showed frequent US abnormalities. These abnormalities in HD patients appear to be more related to age and gender and may be asymptomatic.
Collapse
Affiliation(s)
- Samar Tharwat
- Rheumatology & Immunology Unit, Department of Internal Medicine, Faculty of Medicine, Mansoura University, Mansoura 35516, Egypt
- Department of Internal Medicine, Faculty of Medicine, Horus University, New Damietta 34517, Egypt;
| | - Marwa Saleh
- Mansoura Nephrology & Dialysis Unit (MNDU), Department of Internal Medicine, Faculty of Medicine, Mansoura University, Mansoura 35516, Egypt; (M.S.); (R.E.)
| | - Rabab Elrefaey
- Mansoura Nephrology & Dialysis Unit (MNDU), Department of Internal Medicine, Faculty of Medicine, Mansoura University, Mansoura 35516, Egypt; (M.S.); (R.E.)
| | - Mona Kamal Nassar
- Department of Radiology, Student Hospital, Mansoura University, Mansoura 35516, Egypt;
| | - Mohammed Kamal Nassar
- Department of Internal Medicine, Faculty of Medicine, Horus University, New Damietta 34517, Egypt;
- Mansoura Nephrology & Dialysis Unit (MNDU), Department of Internal Medicine, Faculty of Medicine, Mansoura University, Mansoura 35516, Egypt; (M.S.); (R.E.)
| |
Collapse
|
2
|
Selame L, Walsh L, Schwid M, Al Jalbout N, Gray MR, Dashti M, Shokoohi H. Point-of-Care Ultrasound Unveiling Rotator Cuff Injuries in the Emergency Department: A Case Series. Cureus 2023; 15:e47665. [PMID: 38021501 PMCID: PMC10670987 DOI: 10.7759/cureus.47665] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/24/2023] [Indexed: 12/01/2023] Open
Abstract
Acute shoulder pain is a common ED presentation with a wide range of pathologies that are often initially investigated with radiography. However, diagnosing rotator cuff injuries often requires further imaging for proper diagnosis and management. Bedside shoulder ultrasound is an application that allows for the evaluation of ligaments and tendons in addition to bony structures, all while utilizing direct patient feedback of focally tender areas, expediting diagnosis and therapeutic intervention. In this case series, we discuss our evaluation of patients with suspected rotator cuff pathology and the practice of using the stepwise shoulder ultrasound protocol. Four cases are presented that illustrate the use of shoulder ultrasound in diagnosing biceps tendon injury, supraspinatus tear, chronic supraspinatus tear with hemarthrosis, and subacromial-subdeltoid bursitis. This narrative highlights the valuable role of shoulder ultrasound for the expedited diagnosis and management of patients whose initial shoulder radiographs do not indicate any bony abnormalities.
Collapse
Affiliation(s)
- Lauren Selame
- Emergency Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, USA
| | - Lindsay Walsh
- Emergency Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, USA
- Emergency Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, USA
| | - Madeline Schwid
- Emergency Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, USA
| | - Nour Al Jalbout
- Emergency Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, USA
| | - Morgan R Gray
- Emergency Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, USA
| | - Munaa Dashti
- Emergency Medicine, Amiri Hospital, Kuwait City, KWT
| | - Hamid Shokoohi
- Emergency Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, USA
| |
Collapse
|
3
|
Chen X, Wang Y, Chen J, Zhang F, Xu L, Yan X, Zhu Y, Zhang Q, Tang J. Clinical value of three-dimensional ultrasonography in the morphologic evaluation of rotator cuff tear: a prospective study. Eur Radiol 2023; 33:2331-2339. [PMID: 36418625 DOI: 10.1007/s00330-022-09213-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Revised: 08/15/2022] [Accepted: 10/09/2022] [Indexed: 11/27/2022]
Abstract
OBJECTIVE To study the clinical value of three-dimensional ultrasonography (3D-US) in the morphological evaluation of rotator cuff tears (RCTs). METHODS Based on previously published literature, RCT patterns in our study were divided into crescent, L-shaped with the remnant tendon retracted to the anterior rotator cuff (aL-shaped), L-shaped with the remnant tendon retracted to the posterior rotator cuff (pL-shaped), T-shaped (a tear pattern that is a combination of aL-shaped and pL-shaped), U-shaped, and massive type. Two radiologists prospectively assessed the tear patterns using 3D-US as well as magnetic resonance imaging (MRI) and compared these results using arthroscopy to calculate diagnostic accuracy. RESULT Fifty-two patients (52 shoulders) were enrolled. The overall diagnostic accuracy of 3D-US in evaluating RCT patterns (82.7%, 43/52; 95% CI: 72.1-93.3%) was significantly higher (p = 0.008) than that of the MRI (57.7%, 31/52; 95% CI: 45.8-73.4%). The accuracy of 3D-US was higher than that of MRI for most types of tears (crescent: 95.0% vs. 55.0%, aL-shaped: 83.3% vs. 77.8%, pL-shaped: 50.0% vs. 25.0%, T-shaped: 75.0% vs. 0.0%, and massive type: 80.0% vs. 100.0%). The accuracies of 3D-US with respect to evaluation by the two radiologists were 84.6% (44/52) and 76.9% (40/52), and there was substantial agreement evident (κ = 0.709). The time taken by the two radiologists to reconstruct the 3D-US images and evaluate the tear pattern was < 5 min. CONCLUSION The 3D-US can be used for the preoperative evaluation of RCT patterns, and thus be useful for the correct selection of the surgical repair technique for RCTs. KEY POINTS • Few studies have been found exploring the value of 3D-US for the morphological evaluation of RCTs and correlated with the arthroscopic findings. • Based on previous studies on the morphological classification, anterior L shape (aL-shaped), and posterior L shape (pL-shaped) were used for the first time to describe the torn patterns of RCT.
Collapse
Affiliation(s)
- Xianghui Chen
- Chinese People's Liberation Army (PLA) Medical School, Fuxing Road 28, Beijing, 100853, China.,Department of Ultrasound, The First Medical Center of PLA General Hospital, Fuxing Road 28, Beijing, 100853, China
| | - Yuexiang Wang
- Department of Ultrasound, The First Medical Center of PLA General Hospital, Fuxing Road 28, Beijing, 100853, China
| | - Jian Chen
- Nankai University, Weijin Road 94, Nankai District, Tianjin, 300071, China
| | - Fei Zhang
- Department of Orthopedics, The First Medical Center of PLA General Hospital, Fuxing Road 28, Beijing, 100853, China
| | - Lin Xu
- Department of Radiology, The First Medical Center of PLA General Hospital, Fuxing Road 28, Beijing, 100853, China
| | - Xu Yan
- Department of Radiology, The First Medical Center of PLA General Hospital, Fuxing Road 28, Beijing, 100853, China
| | - Yaqiong Zhu
- Department of Ultrasound, The First Medical Center of PLA General Hospital, Fuxing Road 28, Beijing, 100853, China
| | - Qiang Zhang
- Department of Orthopedics, The First Medical Center of PLA General Hospital, Fuxing Road 28, Beijing, 100853, China.
| | - Jie Tang
- Department of Ultrasound, The First Medical Center of PLA General Hospital, Fuxing Road 28, Beijing, 100853, China.
| |
Collapse
|
4
|
Probe Selection. Regen Med 2023. [DOI: 10.1007/978-3-030-75517-1_12] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2022] Open
|
5
|
Kim DM, Seo JS, Jeon IH, Cho C, Koh KH. Detection of Rotator Cuff Tears by Ultrasound: How Many Scans Do Novices Need to Be Competent? Clin Orthop Surg 2021; 13:513-519. [PMID: 34868501 PMCID: PMC8609212 DOI: 10.4055/cios20259] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/21/2020] [Revised: 01/02/2021] [Accepted: 02/02/2021] [Indexed: 11/21/2022] Open
Abstract
Background Ultrasound is commonly used for evaluating rotator cuff tears. However, little training in ultrasound imaging is provided during orthopedic residents’ training period. Therefore, we performed this study to determine how many ultrasound scans are required for orthopedic residents to be competent and self-confident in the diagnosis of supraspinatus tendon tears and to investigate whether senior residents outperformed junior residents. Methods We studied two third-year residents who had no previous experience of shoulder ultrasound and evaluated their ability to detect rotator cuff pathologies. Their learning curves were plotted using a cumulative summation analysis with a 20% acceptable failure rate compared to arthroscopic findings. Downward, upward, and horizontal cumulative summation trends indicated incompetence, exceptional competence, and competence, respectively. The diagnostic accuracy of third-year residents was compared with that of second-year residents and the number of cases required to gain self-confidence was evaluated. Results Cumulative summation analysis showed that after 26–28 scans, residents achieved the competence to correctly diagnose supraspinatus tears: an upward trend was observed from the beginning for full-thickness tears and a downward trend was observed for partial-thickness tears. Sensitivity and specificity were 0.95 and 0.79, respectively, for third-year residents and 0.91 and 0.58, respectively, for second-year residents. Residents reported self-confidence after 30 ultrasound scans for the detection of rotator cuff tears. Conclusions The number of scans that novices needed to be competent for detecting rotator cuff tears was approximately 30 cases, and the diagnostic accuracy of third-year residents was significantly higher than that of second-year residents.
Collapse
Affiliation(s)
- Dong Min Kim
- Department of Orthopaedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Jae-Seong Seo
- Department of Orthopaedic Surgery, Seoul Medical Center, Seoul, Korea
| | - In-Ho Jeon
- Department of Orthopaedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Changho Cho
- Department of Orthopaedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Kyoung Hwan Koh
- Department of Orthopaedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| |
Collapse
|
6
|
Ultrasound findings of plantar plate tears of the lesser metatarsophalangeal joints. Skeletal Radiol 2021; 50:1513-1525. [PMID: 33423073 DOI: 10.1007/s00256-020-03708-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/03/2020] [Revised: 12/29/2020] [Accepted: 12/29/2020] [Indexed: 02/02/2023]
Abstract
Lesser metatarsophalangeal (MTP) joint plantar plate tears are a common and increasingly recognised cause of metatarsalgia, MTP joint instability and forefoot deformity. Increased interest in early accurate diagnosis of plantar plate tears follows recent surgical innovations allowing direct plantar plate repair. The purpose of this review is to describe the ultrasound features of normal lesser MTP joint plantar plates and to characterise and illustrate the direct and indirect ultrasound findings of plantar plate tears. Lesser MTP joint plantar plate tears are most commonly located at the 2nd MTP joint, involving the lateral distal plantar plate insertion with variable propagation medially and proximally. The most common ultrasound appearance of a plantar plate tear is a discrete partial or full thickness hypoechoic defect in the plate substance. Flattening and attenuation or non-visualisation of the plantar plate represent more extensive tears. Dynamic imaging with toe dorsiflexion improves visualisation of tears and augments MTP joint subluxation. A common indirect finding is pericapsular fibrosis along the MTP joint capsule adjacent to a plantar plate tear, which requires differentiation from Morton's neuroma, and key distinguishing features at ultrasound are described. Other indirect findings include the cartilage interface sign, flexor tendon subluxation onto the metatarsal head or medial to the midline, flexor tenosynovitis, proximal phalangeal enthesophytes or avulsion and MTP joint synovitis. Ultrasound offers several advantages over MR imaging but requires a meticulous ultrasound examination, and optimisation of scanning technique is described.
Collapse
|
7
|
Xin Ooi MW, Fenning L, Dhir V, Basu S. Rotator cuff assessment on imaging. J Clin Orthop Trauma 2021; 18:121-135. [PMID: 33996457 PMCID: PMC8102769 DOI: 10.1016/j.jcot.2021.04.004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/27/2021] [Revised: 03/28/2021] [Accepted: 04/03/2021] [Indexed: 11/29/2022] Open
Abstract
The rotator cuff is a group of four muscles and tendons surrounding the shoulder joint providing it strength and stability. The rotator cuff consists of the subscapularis, supraspinatus, infraspinatus and teres minor. Many shoulder complaints are caused by rotator cuff pathology such as impingement syndrome, tendon tears and other diseases e.g. calcific tendonitis. Diagnosis starts with clinical history and physical examination, after which imaging is often used to help confirm clinical findings depending on the differential diagnosis. The aim of the article is to review the frequently used imaging modalities to assess the rotator cuff and cuff-related disease, specifically focusing on radiography, ultrasonography and magnetic resonance imaging. This article will outline the advantages and disadvantages for each modality and illustrate typical radiological findings of common rotator cuff pathologies.
Collapse
Affiliation(s)
| | | | | | - Subhasis Basu
- Corresponding author. Radiology Department, Wrightington, Wigan and Leigh NHS Trust, Hall Ln, Appley Bridge, Wigan, WN6 9EP, United Kingdom.
| |
Collapse
|
8
|
Serpi F, Albano D, Rapisarda S, Chianca V, Sconfienza LM, Messina C. Shoulder ultrasound: current concepts and future perspectives. J Ultrason 2021; 21:e154-e161. [PMID: 34258041 PMCID: PMC8264812 DOI: 10.15557/jou.2021.0025] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2021] [Accepted: 04/19/2021] [Indexed: 11/22/2022] Open
Abstract
Ultrasonography is an established and effective imaging technique that can be used to evaluate articular and periarticular structures around the shoulder. It has been shown to be useful in a wide range of rotator cuff diseases (e.g. tendon tears, rotator cuff calcific tendinopathy and bursitis) as well as non-rotator cuff abnormalities (instability, synovial joint diseases and nerve entrapment syndrome). A scanning protocol is highly recommended to reduce the rate of operators’ errors by following a standardized scheme including a list of main structures. Shoulder ultrasound has several advantages: it is a relatively cheap and widely available technique, free from ionizing radiation, that can reach excellent diagnostic accuracy even compared to magnetic resonance imaging. Moreover, it is the only imaging technique that allows dynamic evaluation of musculoskeletal structures, which is important for the evaluation of impingement. Also, due to the shoulder’s superficial anatomical position, ultrasound can also be helpful in guiding interventional percutaneous procedures, both for diagnostic (e.g. magnetic resonance arthrography) and therapeutic purposes (e.g. percutaneous treatment of calcific tendonitis). Contrast-enhanced ultrasound and speckle tracking offer complimentary evaluations of shoulder anatomy and biomechanics. Moreover, the advent of ultra-high-frequency US, with probes up to 70 MHz allowing for a resolution as low as 30 μm, is a promising tool for further evaluation of the shoulder anatomy, and diagnostic and therapeutic strategies.
Collapse
Affiliation(s)
- Francesca Serpi
- Postgraduate School of Radiodiagnostics, Università degli Studi di Milano, Milan, Italy
| | - Domenico Albano
- IRCCS Istituto Ortopedico Galeazzi, Milan, Italy.,Sezione di Scienze Radiologiche, Dipartimento di Biomedicina, Neuroscienze e Diagnostica Avanzata, Università degli Studi di Palermo, Palermo, Italy
| | | | - Vito Chianca
- Clinica di Radiologia EOC, Istituto di Imaging della Svizzera Italiana (IIMSI), Lugano, Switzerland.,Ospedale Evangelico Betania, Napoli, Italy
| | - Luca Maria Sconfienza
- IRCCS Istituto Ortopedico Galeazzi, Milan, Italy.,Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, Milan, Italy
| | | |
Collapse
|
9
|
Yoon K, Kim H, Han SB, Song HS. Ultrasound Findings Aid Decisions to Repair Partial Articular Supraspinatus Tendon Avulsion. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2020; 39:2005-2011. [PMID: 32324303 DOI: 10.1002/jum.15307] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/09/2020] [Accepted: 04/01/2020] [Indexed: 06/11/2023]
Abstract
OBJECTIVES Ultrasound (US) is useful for diagnosing full-thickness rotator cuff tears and high-grade partial-thickness bursal-side tears. However, anisotropy artifacts make it difficult to identify partial articular supraspinatus tendon avulsion (PASTA) by US. This study was performed to determine the diagnostic accuracy of US for PASTA and to uncover sensitive findings that could aid decisions to repair. METHODS Patients who underwent preoperative US examinations and supraspinatus tendon confirmation by arthroscopic examinations were enrolled. We analyzed 52 PASTA cases involving greater than 50% thickness of the tendon and 52 age- and sex-matched cases with an intact supraspinatus. Two orthopedic surgeons blinded to the diagnosis interpreted US videos of the supraspinatus tendon. Six findings (echo defect, tendon delamination, echo change, tendon thickness, tendon fiber pattern, and cartilage interface sign) were assessed. We calculated the sensitivity, specificity, and accuracy for each US finding. RESULTS The cases consisted of 46 men and 58 women. The US diagnosis of PASTA showed sensitivity of 64.7%, specificity of 94.1%, and accuracy of 79.4%. The echo change in the short axis showed the highest sensitivity. Thinning and delamination showed the highest specificity of 100%. In contrast to previous reports, the sensitivity of the cartilage interface sign was low in both long-axis images (17.6%) and short-axis images (29.4%). CONCLUSIONS Preoperative diagnostic US to aid decisions regarding PASTA repair showed high specificity (94.1%) and moderate accuracy (79.4%). However, the sensitivity was only 64.7% and was affected by the examiner's experience with US.
Collapse
Affiliation(s)
- Kisyck Yoon
- Department of Orthopedic Surgery, Eunpyeong St Mary's Hospital, College of Medicine, Catholic University of Korea, Seoul, South Korea
| | - Hyungsuk Kim
- Department of Orthopedic Surgery, Eunpyeong St Mary's Hospital, College of Medicine, Catholic University of Korea, Seoul, South Korea
| | - Sung Bin Han
- Department of Orthopedic Surgery, Eunpyeong St Mary's Hospital, College of Medicine, Catholic University of Korea, Seoul, South Korea
| | - Hyun Seok Song
- Department of Orthopedic Surgery, Eunpyeong St Mary's Hospital, College of Medicine, Catholic University of Korea, Seoul, South Korea
| |
Collapse
|
10
|
Wu WT, Chang KV, Hsu YC, Hsu PC, Ricci V, Özçakar L. Artifacts in Musculoskeletal Ultrasonography: From Physics to Clinics. Diagnostics (Basel) 2020; 10:diagnostics10090645. [PMID: 32867385 DOI: 10.3390/diagnostics10090645.pmid:32867385;pmcid:pmc7555047] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2020] [Revised: 08/21/2020] [Accepted: 08/24/2020] [Indexed: 05/26/2023] Open
Abstract
Ultrasound appears to be the most useful imaging tool in the diagnosis and guided treatment of musculoskeletal disorders. However, ultrasonography has been criticized for being user dependent. Therefore, medical professionals should be familiar with the basic principles of ultrasound imaging (e.g., physics and technical skills) to diminish artifacts and avoid misinterpretation. In this review, we focused on the physics of common artifacts, their clinical significance, and the ways to tackle them in daily practice during musculoskeletal imaging. In particular, artifacts pertaining to the focal zone, beam attenuation, path and side lobe of the beam, speed of the sound, and range ambiguity were described.
Collapse
Affiliation(s)
- Wei-Ting Wu
- Department of Physical Medicine and Rehabilitation, National Taiwan University Hospital, Bei-Hu Branch, Taipei 10845, Taiwan
- Department of Physical Medicine and Rehabilitation, National Taiwan University College of Medicine, Taipei 10048, Taiwan
| | - Ke-Vin Chang
- Department of Physical Medicine and Rehabilitation, National Taiwan University Hospital, Bei-Hu Branch, Taipei 10845, Taiwan
- Department of Physical Medicine and Rehabilitation, National Taiwan University College of Medicine, Taipei 10048, Taiwan
| | - Yu-Chun Hsu
- Department of Physical Medicine and Rehabilitation, Taipei Veterans General Hospital, Taipei 11221, Taiwan
| | - Po-Cheng Hsu
- Department of Physical Medicine and Rehabilitation, National Taiwan University Hospital, Bei-Hu Branch, Taipei 10845, Taiwan
| | - Vincenzo Ricci
- Department of Biomedical and Neuromotor Science, Physical and Rehabilitation Medicine Unit, Istituto di Ricovero e Cura a Carattere Scientifico Rizzoli Orthopedic Institute, 40136 Bologna, Italy
| | - Levent Özçakar
- Department of Physical and Rehabilitation Medicine, Hacettepe University Medical School, Ankara 06100, Turkey
| |
Collapse
|
11
|
Wu WT, Chang KV, Hsu YC, Hsu PC, Ricci V, Özçakar L. Artifacts in Musculoskeletal Ultrasonography: From Physics to Clinics. Diagnostics (Basel) 2020; 10:diagnostics10090645. [PMID: 32867385 PMCID: PMC7555047 DOI: 10.3390/diagnostics10090645] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2020] [Revised: 08/21/2020] [Accepted: 08/24/2020] [Indexed: 12/11/2022] Open
Abstract
Ultrasound appears to be the most useful imaging tool in the diagnosis and guided treatment of musculoskeletal disorders. However, ultrasonography has been criticized for being user dependent. Therefore, medical professionals should be familiar with the basic principles of ultrasound imaging (e.g., physics and technical skills) to diminish artifacts and avoid misinterpretation. In this review, we focused on the physics of common artifacts, their clinical significance, and the ways to tackle them in daily practice during musculoskeletal imaging. In particular, artifacts pertaining to the focal zone, beam attenuation, path and side lobe of the beam, speed of the sound, and range ambiguity were described.
Collapse
Affiliation(s)
- Wei-Ting Wu
- Department of Physical Medicine and Rehabilitation, National Taiwan University Hospital, Bei-Hu Branch, Taipei 10845, Taiwan; (W.-T.W.); (P.-C.H.)
- Department of Physical Medicine and Rehabilitation, National Taiwan University College of Medicine, Taipei 10048, Taiwan
| | - Ke-Vin Chang
- Department of Physical Medicine and Rehabilitation, National Taiwan University Hospital, Bei-Hu Branch, Taipei 10845, Taiwan; (W.-T.W.); (P.-C.H.)
- Department of Physical Medicine and Rehabilitation, National Taiwan University College of Medicine, Taipei 10048, Taiwan
- Correspondence:
| | - Yu-Chun Hsu
- Department of Physical Medicine and Rehabilitation, Taipei Veterans General Hospital, Taipei 11221, Taiwan;
| | - Po-Cheng Hsu
- Department of Physical Medicine and Rehabilitation, National Taiwan University Hospital, Bei-Hu Branch, Taipei 10845, Taiwan; (W.-T.W.); (P.-C.H.)
| | - Vincenzo Ricci
- Department of Biomedical and Neuromotor Science, Physical and Rehabilitation Medicine Unit, Istituto di Ricovero e Cura a Carattere Scientifico Rizzoli Orthopedic Institute, 40136 Bologna, Italy;
| | - Levent Özçakar
- Department of Physical and Rehabilitation Medicine, Hacettepe University Medical School, Ankara 06100, Turkey;
| |
Collapse
|
12
|
Liu F, Dong J, Shen WJ, Kang Q, Zhou D, Xiong F. Detecting Rotator Cuff Tears: A Network Meta-analysis of 144 Diagnostic Studies. Orthop J Sports Med 2020; 8:2325967119900356. [PMID: 32076627 PMCID: PMC7003181 DOI: 10.1177/2325967119900356] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/18/2019] [Accepted: 10/10/2019] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND Many imaging techniques have been developed for the detection of rotator cuff tears (RCTs). Despite numerous quantitative diagnostic studies, their relative accuracy remains inconclusive. PURPOSE To determine which of 3 commonly used imaging modalities is optimal for the diagnosis of RCTs. STUDY DESIGN Systematic review; Level of evidence, 4. METHODS Studies evaluating the performance of magnetic resonance imaging (MRI), magnetic resonance arthrography (MRA), and ultrasound (US) used in the detection of RCTs were retrieved from the PubMed/MEDLINE and Embase databases. Diagnostic data were extracted from articles that met the inclusion/exclusion criteria. A network meta-analysis was performed using an arm-based model to pool the absolute sensitivity and specificity, relative sensitivity and specificity, and diagnostic odds ratio as well as the superiority index for ranking the probability of these techniques. RESULTS A total of 144 studies involving 14,059 patients (14,212 shoulders) were included in this network meta-analysis. For the detection of full-thickness (FT) tears, partial-thickness (PT) tears, or any tear, MRA had the highest sensitivity, specificity, and superiority index. For the detection of any tear, MRI had better performance than US (sensitivity: 0.84 vs 0.81, specificity: 0.86 vs 0.82, and superiority index: 0.98 vs 0.22, respectively). With regard to FT tears, MRI had a higher sensitivity and superiority index than US (0.91 vs 0.87 and 0.67 vs 0.28, respectively) and a similar specificity (0.88 vs 0.88, respectively). The results for PT tears were similar to the detection of FT tears. A sensitivity analysis was performed by removing studies involving only 1 arm for FT tears, PT tears, or any tear, and the results remained stable. CONCLUSION This network meta-analysis of diagnostic tests revealed that high-field MRA had the highest diagnostic value for detecting any tear, followed by low-field MRA, high-field MRI, high-frequency US, low-field MRI, and low-frequency US. These findings can help guide clinicians in deciding on the appropriate imaging modality.
Collapse
Affiliation(s)
- Fanxiao Liu
- Department of Orthopedic Surgery, Shandong Provincial Hospital, Shandong University, Jinan, China
| | - Jinlei Dong
- Department of Orthopedic Surgery, Shandong Provincial Hospital, Shandong University, Jinan, China
| | - Wun-Jer Shen
- Po Cheng Orthopedic Institute, Kaohsiung, Taiwan
| | - Qinglin Kang
- Department of Orthopedic Surgery, Shanghai Sixth People’s Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Dongsheng Zhou
- Department of Orthopedic Surgery, Shandong Provincial Hospital, Shandong University, Jinan, China
| | - Fei Xiong
- Department of Orthopedic Surgery, Shanghai Sixth People’s Hospital, Shanghai Jiao Tong University, Shanghai, China
- Fei Xiong, MD, Department of Orthopedic Surgery, Shanghai Sixth People’s Hospital, Shanghai Jiao Tong University, Yishan Road 600, Xuhui District, Shanghai 200233, China ()
| |
Collapse
|
13
|
Sabharwal T, Khanduri S, Khan S, Husain M, Singh A, Khan AU, Abbas SZ, Singh H. A Comparative Assessment Between High-resolution Ultrasonography and Field Magnetic Resonance Imaging in Supraspinatus Tear Cases and Its Arthroscopic Correlation. Cureus 2019; 11:e5627. [PMID: 31700730 PMCID: PMC6822911 DOI: 10.7759/cureus.5627] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Background Diagnosis of a supraspinatus tear in patients presenting with shoulder pain is a difficult task and often requires the help of an MRI. However, in recent years, high-resolution ultrasonography (USG) has been utilized as a cheaper yet sensitive alternative. The aim of the study is to provide a comparative assessment of supraspinatus tears between USG and MRI in relation to arthroscopic results. Methods A total of 60 patients with shoulder pain for the last three months or more scheduled to undergo arthroscopic surgery for their shoulder disorder were enrolled; those having any congenital deformity of the shoulder or having any contradiction to an MRI were excluded from the assessment. All the patients underwent high-resolution ultrasonography (HRUSG) and MRI evaluation. Both the USG and MRI findings were correlated with the arthroscopic findings. Results On ultrasonography, 34 (56.67%) full-thickness tears and 22 (36.67%) partial-thickness tears of the supraspinatus were detected. On MRI, 36 (60.0%) were diagnosed as a full-thickness tear and 20 (33.33%) as a partial-thickness tear. After arthroscopy, 36 (60.00%) were confirmed as a full-thickness tear and 20 (33.33%) as a partial-thickness tear of the supraspinatus. For a full-thickness tear, the sensitivity and specificity of USG and MRI were 95.0% and 92.5%, and 85% and 92.5%, respectively. For a full-thickness tear, the sensitivity and specificity of the modalities were 94.4% and 100%, respectively. Conclusion HRUSG and MRI both had high comparable accuracy for detection of a supraspinatus tear, however, HRUSG had an edge over MRI in the detection of a partial tear.
Collapse
Affiliation(s)
- Tushar Sabharwal
- Radiodiagnosis, Era's Lucknow Medical College and Hospital, Lucknow, IND
| | - Sachin Khanduri
- Radiology, Era's Lucknow Medical College and Hospital, Lucknow, IND
| | - Shahla Khan
- Radiology, Era's Lucknow Medical College and Hospital, Lucknow, IND
| | - Mushahid Husain
- Radiology, Era's Lucknow Medical College and Hospital, Lucknow, IND
| | - Anchal Singh
- Radiodiagnosis, Era's Lucknow Medical College and Hospital, Lucknow, IND
| | - Ahmad Umar Khan
- Radiodiagnosis, Era's Lucknow Medical College and Hospital, Lucknow, IND
| | - Syed Zain Abbas
- Radiodiagnosis, Era's Lucknow Medical College and Hospital, Lucknow, IND
| | - Harshika Singh
- Radiodiagnosis, Era's Lucknow Medical College and Hospital, Lucknow, IND
| |
Collapse
|
14
|
Strakowski JA, Visco CJ. Diagnostic and therapeutic musculoskeletal ultrasound applications of the shoulder. Muscle Nerve 2019; 60:1-6. [PMID: 31054148 DOI: 10.1002/mus.26505] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2019] [Accepted: 04/28/2019] [Indexed: 11/10/2022]
Abstract
High frequency ultrasound is a valuable tool for assessing soft tissue injuries about the shoulder. It has advantages over other imaging modalities including relatively low cost, portability, and dynamic real-time visualization. It has a high sensitivity for identifying tendon degeneration, bursitis, and rotator cuff tears. Ultrasound is also an excellent modality for diagnostic and therapeutic needle-guided procedures. A detailed knowledge of shoulder anatomy and transducer positioning is required for obtaining adequate diagnostic value from ultrasound. This Monograph is designed to help develop scanning protocols for optimizing image acquisition for musculoskeletal assessment of the shoulder. Muscle Nerve, 2019.
Collapse
Affiliation(s)
- Jeffrey A Strakowski
- Department of Physical Medicine and Rehabilitation, The Ohio State University, Columbus, Ohio, USA.,OhioHealth Riverside Methodist Hospital, 3555 Olentangy River Road, Columbus, 43214, Ohio, USA.,The McConnell Spine, Sport, and Joint Center, Columbus, Ohio, USA
| | - Christopher J Visco
- Department of Rehabilitation and Regenerative Medicine, Columbia University College of Physicians and Surgeons, New York, New York, USA
| |
Collapse
|
15
|
Chin K, Chowdhury A, Leivadiotou D, Marmery H, Ahrens PM. The accuracy of plain radiographs in diagnosing degenerate rotator cuff disease. Shoulder Elbow 2019; 11:46-51. [PMID: 31019562 PMCID: PMC6463379 DOI: 10.1177/1758573217743942] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/21/2017] [Revised: 07/25/2017] [Accepted: 10/17/2017] [Indexed: 11/16/2022]
Abstract
BACKGROUND A number of radiographic signs have been previously demonstrated to be associated with degenerative rotator cuff tears. An ability to predict the presence of a tear by radiography would permit the early commencement of appropriate treatment and the avoidance of unnecessary invasive investigations. The aim of the present study was to determine the accuracy of using radiographic signs to predict the presence of a cuff tear on arthroscopy. METHODS Fifty consecutive patients who had undergone shoulder arthroscopy and had pre-operative plain radiographs were included. Pre-operative radiographs were reviewed by a consultant shoulder surgeon, a consultant radiologist and a senior clinical fellow for the following signs: acromial spur; subjective reduction of subacromial space; sourcil sign; acromial acetabularization; os acromiale; greater tuberosity cortical irregularity; greater tuberosity sclerosis; humeral head rounding; cyst; and reduction in acromiohumeral head distance. RESULTS The presence of tuberosity sclerosis (p < 0.0001), tuberosity irregularities (p < 0.0001), tuberosity cyst (p = 0.004) and sourcil sign (p = 0.019) was associated with the presence of a rotator cuff tear. The combined sensitivity of prediction of tear by the observers following radiographic review was 91.7%, with a combined negative predictive value of 80%. CONCLUSIONS The assessment of radiographs by senior clinicians is a useful tool for confirming the absence of a rotator cuff tear.
Collapse
Affiliation(s)
- Kuen Chin
- Kuen Chin, Ponders Street, Royal Free London
NHS Foundation Trust, London NW3 2QG, UK.
| | | | | | | | | |
Collapse
|
16
|
Tang YQ, Zeng C, Su XT, Li SS, Yi WH, Xu JJ, Wu GQ, Chen YJ, Li MW, Liu HM. The Value of Percutaneous Shoulder Puncture with Contrast-enhanced Ultrasound in Differentiation of Rotator Cuff Tear Subtypes: A Preliminary Prospective Study. ULTRASOUND IN MEDICINE & BIOLOGY 2019; 45:660-671. [PMID: 30578038 DOI: 10.1016/j.ultrasmedbio.2018.10.012] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/12/2018] [Revised: 09/11/2018] [Accepted: 10/04/2018] [Indexed: 06/09/2023]
Abstract
Imaging tests perform relatively well in the detection of rotator cuff tears (RCTs), exhibiting high sensitivity and specificity, mainly among larger full-thickness tears (tear width >1 cm). However, these tests are relatively less accurate in the detection of small full-thickness tears and partial-thickness tears. The purpose of this study was to determine the feasibility of percutaneous ultrasound-guided tendon lesionography (PUTL) using the SonoVue and the value of percutaneous shoulder puncture via contrast-enhanced ultrasound (CEUS)-a combination of percutaneous ultrasound-guided subacromial bursography (PUSB) and PUTL-in the detection of RCT subtypes. Conventional ultrasound (US), CEUS and magnetic resonance imaging (MRI) were performed and prospectively evaluated in 97 patients who had undergone arthroscopy because of suspected RCTs. The rates of detection of the various subtypes of RCTs using CEUS, PUSB, PUTL, US and MRI were evaluated. The RCT subtype detection rate via CEUS was significantly higher than the rates via US and MRI (96.9%, 74.2% and 76.3%, respectively), as were the detection rates for small full-thickness tears combined with partial-thickness tears (98.2%, 60.0% and 61.8%, respectively). The detection rate with PUSB was significantly higher than those with US and MRI in assessing full-thickness tears combined with bursal-side partial-thickness tears (93.9%, 65.3% and 65.3%, respectively). The detection rate with PUTL was significantly higher than those with US and MRI in assessing the corresponding subtypes (100.0%, 69.2% and 76.9%, respectively). On the basis of our findings, we consider PUTL a tolerable and feasible procedure. Percutaneous shoulder puncture using CEUS can be an effective alternative method with better diagnostic performance than US and MRI for the detection of RCT subtypes.
Collapse
Affiliation(s)
- Ya-Qun Tang
- Department of Ultrasound, Guangdong Second Provincial General Hospital, Guangzhou, China; Department of Ultrasound, Zhuhai Hospital Affiliated with Jinan University, Zhuhai People's Hospital, Zhuhai, China
| | - Chun Zeng
- Department of Sports Medicine and Arthroscopy, Third Affiliated Hospital of Southern Medical University, Orthopaedic Institute of Guangdong Province, Guangzhou, China
| | - Xun-Tong Su
- Department of Sports Medicine and Arthroscopy, Third Affiliated Hospital of Southern Medical University, Orthopaedic Institute of Guangdong Province, Guangzhou, China
| | - Su-Shu Li
- Department of Ultrasound, Guangdong Second Provincial General Hospital, Guangzhou, China
| | - Wen-Hong Yi
- Department of Ultrasound, Guangdong Second Provincial General Hospital, Guangzhou, China
| | - Jing-Jiao Xu
- Department of Ultrasound, Guangdong Second Provincial General Hospital, Guangzhou, China
| | - Gui-Qin Wu
- Department of Sports Medicine and Arthroscopy, Third Affiliated Hospital of Southern Medical University, Orthopaedic Institute of Guangdong Province, Guangzhou, China
| | - Yan-Jun Chen
- Department of Medical Imaging, Third Affiliated Hospital of Southern Medical University, Orthopaedic Institute of Guangdong Province, Guangzhou, China
| | - Mian-Wen Li
- Department of Medical Imaging, Third Affiliated Hospital of Southern Medical University, Orthopaedic Institute of Guangdong Province, Guangzhou, China
| | - Hong-Mei Liu
- Department of Ultrasound, Guangdong Second Provincial General Hospital, Guangzhou, China.
| |
Collapse
|
17
|
|
18
|
Washburn N, Onishi K, Wang JHC. Ultrasound elastography and ultrasound tissue characterisation for tendon evaluation. J Orthop Translat 2018; 15:9-20. [PMID: 30258782 PMCID: PMC6148731 DOI: 10.1016/j.jot.2018.06.003] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/10/2018] [Revised: 06/04/2018] [Accepted: 06/07/2018] [Indexed: 12/16/2022] Open
Abstract
Ultrasound elastography (UE) and ultrasound tissue characterisation (UTC) are two newer modes of ultrasound (US) which have begun to attract scientific interests as ways to improve tendon characterisation. These modes of US show early promise in improved diagnostic accuracy, prediction of at-risk tendons and prognostication capability beyond conventional grey-scale US. Here, we provide a review of the literature on UE and UTC for Achilles, patellar and rotator cuff tendons. The translational potential of this article: The present literature indicates that UE and UTC could potentially increase the clinician's ability to accurately diagnose the extent of tendon pathology, including preclinical injury.
Collapse
Affiliation(s)
- Neal Washburn
- Department of Physical Medicine and Rehabilitation, University of Pittsburgh Medical Center, Kaufman Building, 3471 Fifth Avenue, Suite 201, Pittsburgh, PA, 15213, USA
| | - Kentaro Onishi
- Department of Physical Medicine and Rehabilitation, University of Pittsburgh Medical Center, Kaufman Building, 3471 Fifth Avenue, Suite 201, Pittsburgh, PA, 15213, USA.,Department of Orthopaedic Surgery, University of Pittsburgh Medical Center, Kaufman Building, 3471 Fifth Avenue, Suite 1011, Pittsburgh, PA, 15213, USA
| | - James H-C Wang
- MechanoBiology Laboratory, Department of Orthopaedic Surgery, University of Pittsburgh School of Medicine, 210 Lothrop Street, BST, E1640, Pittsburgh, PA 15213, USA
| |
Collapse
|
19
|
Baloch N, Hasan OH, Jessar MM, Hattori S, Yamada S. “Sports Ultrasound”, advantages, indications and limitations in upper and lower limbs musculoskeletal disorders. Review article. Int J Surg 2018; 54:333-340. [DOI: 10.1016/j.ijsu.2017.11.034] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2017] [Revised: 11/18/2017] [Accepted: 11/20/2017] [Indexed: 11/26/2022]
|
20
|
Finley M, Ebaugh D, Trojian T. Agreement of Musculoskeletal Ultrasound and Clinical Assessment of Shoulder Impairment in Manual Wheelchair Users With Various Duration of Spinal Cord Injury. Arch Phys Med Rehabil 2018; 99:615-622. [DOI: 10.1016/j.apmr.2017.12.015] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2017] [Revised: 12/06/2017] [Accepted: 12/18/2017] [Indexed: 10/18/2022]
|
21
|
Kostopoulos D, Rawat M. Demystifying shoulder pain with electrodiagnosis and musculoskeletal ultrasound imaging. J Bodyw Mov Ther 2017; 21:983-985. [PMID: 29037656 DOI: 10.1016/j.jbmt.2017.09.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2017] [Revised: 09/07/2017] [Accepted: 09/08/2017] [Indexed: 11/24/2022]
Affiliation(s)
- Dimitrios Kostopoulos
- Board Certified in Clinical Electrophysiology, Charles E. Schmidt College of Medicine at Florida Atlantic University, 66 Mineola Ave, #1342, Roslyn Heights, NY 11577, USA.
| | - Mohini Rawat
- Board Certified in Clinical Electrophysiology & Registered in Musculoskeletal Sonography, APCA, 3850 Hudson Manor Terrace, # 6BE, Riverdale, NY 10463, USA.
| |
Collapse
|
22
|
Lee MH, Sheehan SE, Orwin JF, Lee KS. Comprehensive Shoulder US Examination: A Standardized Approach with Multimodality Correlation for Common Shoulder Disease. Radiographics 2017; 36:1606-1627. [PMID: 27726738 DOI: 10.1148/rg.2016160030] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Shoulder pain is one of the most common musculoskeletal conditions encountered in primary care and specialty orthopedic clinic settings. Although magnetic resonance (MR) imaging is typically the modality of choice for evaluating the soft-tissue structures of the shoulder, ultrasonography (US) is becoming an important complementary imaging tool in the evaluation of superficial soft-tissue structures such as the rotator cuff, subacromial-subdeltoid bursa, and biceps tendon. The advantages of US driving its recent increased use include low cost, accessibility, and capability for real-time high-resolution imaging that enables dynamic assessment and needle guidance. As more radiologists are considering incorporating shoulder US into their practices, the development of a standardized approach to performing shoulder US should be a priority to facilitate the delivery of high-quality patient care. Familiarity with and comfort in performing a standardized shoulder US examination, as well as knowledge of the types of anomalies that can be evaluated well with US, will enhance the expertise of those working in musculoskeletal radiology practices and add value in the form of increased patient and health care provider satisfaction. This review describes the utility and benefits of shoulder US as a tool that complements MR imaging in the assessment of shoulder pain. A standardized approach to the shoulder US examination is also described, with a review of the basic technique of this examination, normal anatomy of the shoulder, common indications for shoulder US, and characteristic US findings of common shoulder diseases-with select MR imaging and arthroscopic correlation. Online supplemental material is available for this article. ©RSNA, 2016.
Collapse
Affiliation(s)
- Matthew H Lee
- From the Departments of Radiology (M.H.L., S.E.S., K.S.L.) and Orthopedics and Rehabilitation (J.F.O.), University of Wisconsin School of Medicine and Public Health, Madison, WI
| | - Scott E Sheehan
- From the Departments of Radiology (M.H.L., S.E.S., K.S.L.) and Orthopedics and Rehabilitation (J.F.O.), University of Wisconsin School of Medicine and Public Health, Madison, WI
| | - John F Orwin
- From the Departments of Radiology (M.H.L., S.E.S., K.S.L.) and Orthopedics and Rehabilitation (J.F.O.), University of Wisconsin School of Medicine and Public Health, Madison, WI
| | - Kenneth S Lee
- From the Departments of Radiology (M.H.L., S.E.S., K.S.L.) and Orthopedics and Rehabilitation (J.F.O.), University of Wisconsin School of Medicine and Public Health, Madison, WI
| |
Collapse
|
23
|
Baumer TG, Dischler J, Mende V, Zauel R, van Holsbeeck M, Siegal DS, Divine G, Moutzouros V, Bey MJ. Effects of asymptomatic rotator cuff pathology on in vivo shoulder motion and clinical outcomes. J Shoulder Elbow Surg 2017; 26:1064-1072. [PMID: 28131679 PMCID: PMC5438772 DOI: 10.1016/j.jse.2016.11.048] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/23/2016] [Revised: 11/15/2016] [Accepted: 11/25/2016] [Indexed: 02/01/2023]
Abstract
BACKGROUND The incidence of asymptomatic rotator cuff tears has been reported to range from 15% to 39%, but the influence of asymptomatic rotator cuff pathology on shoulder function is not well understood. This study assessed the effects of asymptomatic rotator cuff pathology on shoulder kinematics, strength, and patient-reported outcomes. METHODS A clinical ultrasound examination was performed in 46 asymptomatic volunteers (age: 60.3 ± 7.5 years) with normal shoulder function to document the condition of their rotator cuff. The ultrasound imaging identified the participants as healthy (n = 14) or pathologic (n = 32). Shoulder motion was measured with a biplane x-ray imaging system, strength was assessed with a Biodex (Biodex Medical Systems, Inc., Shirley, NY, USA), and patient-reported outcomes were assessed using the Western Ontario Rotator Cuff Index and visual analog scale pain scores. RESULTS Compared with healthy volunteers, those with rotator cuff pathology had significantly less abduction (P = .050) and elevation (P = .041) strength, their humerus was positioned more inferiorly on the glenoid (P = .018), and the glenohumeral contact path length was longer (P = .007). No significant differences were detected in the Western Ontario Rotator Cuff Index, visual analog scale, range of motion, or acromiohumeral distance. CONCLUSIONS The differences observed between the healthy volunteers and those with asymptomatic rotator cuff pathology lend insight into the changes in joint mechanics, shoulder strength, and conventional clinical outcomes associated with the early stages of rotator cuff pathology. Furthermore, these findings suggest a plausible mechanical progression of kinematic and strength changes associated with the development of rotator cuff pathology.
Collapse
Affiliation(s)
- Timothy G Baumer
- Bone and Joint Center, Henry Ford Health System, Detroit, MI, USA.
| | - Jack Dischler
- Bone and Joint Center, Henry Ford Health System, Detroit, MI, USA
| | - Veronica Mende
- Bone and Joint Center, Henry Ford Health System, Detroit, MI, USA
| | - Roger Zauel
- Bone and Joint Center, Henry Ford Health System, Detroit, MI, USA
| | | | - Daniel S Siegal
- Department of Radiology, Henry Ford Health System, Detroit, MI, USA
| | - George Divine
- Department of Public Health Sciences, Henry Ford Health System, Detroit, MI, USA
| | - Vasilios Moutzouros
- Department of Orthopaedic Surgery, Henry Ford Health System, Detroit, MI, USA
| | - Michael J Bey
- Bone and Joint Center, Henry Ford Health System, Detroit, MI, USA
| |
Collapse
|
24
|
Okoroha KR, Mehran N, Duncan J, Washington T, Spiering T, Bey MJ, Van Holsbeeck M, Moutzouros V. Characterization of Rotator Cuff Tears: Ultrasound Versus Magnetic Resonance Imaging. Orthopedics 2017; 40:e124-e130. [PMID: 27755645 DOI: 10.3928/01477447-20161013-04] [Citation(s) in RCA: 31] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/20/2016] [Accepted: 08/30/2016] [Indexed: 02/03/2023]
Abstract
Ultrasound and magnetic resonance imaging (MRI) are both capable of diagnosing full-thickness rotator cuff tears. However, it is unknown which imaging modality is more accurate and precise in evaluating the characteristics of full-thickness rotator cuff tears in a surgical population. This study reviewed 114 patients who underwent arthroscopic repair of a full-thickness rotator cuff tear over a 1-year period. Of these patients, 61 had both preoperative MRI and ultrasound for review. Three musculoskeletal radiologists evaluated each ultrasound and MRI in a randomized and blinded fashion on 2 separate occasions. Tear size, retraction status, muscle atrophy, and fatty infiltration were analyzed and compared between the 2 modalities. Ultrasound measurements were statistically smaller in both tear size (P=.001) and retraction status (P=.001) compared with MRI. The 2 image modalities showed comparable intraobserver reliability in assessment of tear size and retraction status. However, MRI showed greater interobserver reliability in assessment of tear size, retraction status, and atrophy. Independent observers are more likely to agree on measurements of the characteristics of rotator cuff tears when using MRI compared with ultrasound. As tear size increases, the 2 image modalities show greater differences in measurement of tear size and retraction status. Additionally, compared with MRI, ultrasound shows consistently low reliability in detecting subtle, but clinically important, degeneration of the soft tissue envelope. Although it is inexpensive and convenient, ultrasound may be best used to identify a tear, and MRI is superior for use in surgical planning for larger tears. [Orthopedics. 2017; 40(1):e124-e130.].
Collapse
|
25
|
Amoo-Achampong K, Nwachukwu BU, McCormick F. An orthopedist's guide to shoulder ultrasound: a systematic review of examination protocols. PHYSICIAN SPORTSMED 2016; 44:407-416. [PMID: 27548649 DOI: 10.1080/00913847.2016.1222224] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
BACKGROUND The utilization of musculoskeletal ultrasound has expanded within the setting of the orthopedic clinic as a cost-effective, point-of-care diagnostic tool for shoulder pathology. In experienced hands, ultrasound exhibits capabilities equivalent to that of magnetic resonance imaging in the diagnosis of many shoulder diseases including full-thickness and partial-thickness rotator cuff tears. Although similarly effective in identifying additional shoulder disease processes, major obstacles to its widespread use include user dependence and intrinsic limitation to extra-articular diagnosis. OBJECTIVES The purpose of this review is to present a step-by-step guide of how to perform a comprehensive shoulder examination and to discuss the appropriate use, economic benefit and implementation of ultrasound within the clinic. METHODS A systematic search (June 2016) of PubMed, Scopus, and EMBASE databases was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines for literature presenting shoulder ultrasound examination protocols. Included studies were peer-reviewed articles or academic society endorsed protocols presenting comprehensive sonographic examinations of the adult shoulder. Papers with limited or single structure examination descriptions, non-English language, and publication dates before 1980 were excluded. Final papers meeting criteria were secondarily screened for publication after 2005 to reflect the current state of ultrasound imaging. RESULTS AND CONCLUSIONS The search yielded 1,725 unique articles with 17 studies meeting final selection criteria. Information from identified studies was summarized to formulate a 4-part shoulder examination protocol, including steps most pertinent to orthopedic in-office diagnoses. In agreement with previous studies, the inexperienced orthopedic surgeon can be quickly trained to expert level proficiency in shoulder ultrasound diagnosis. Using an established protocol, a comprehensive, yet effective shoulder ultrasound examination can be performed within ten minutes. Further, ultrasound provides opportunity to off-set costs through the engagement of revenue generating activity for the orthopedic practice.
Collapse
Affiliation(s)
- Kelms Amoo-Achampong
- a Sports Medicine and Shoulder Division , SOAR Institute , Pompano Beach , FL , USA
| | - Benedict U Nwachukwu
- b Department of Orthopaedic Surgery , Hospital for Special Surgery , New York , NY , USA
| | - Frank McCormick
- a Sports Medicine and Shoulder Division , SOAR Institute , Pompano Beach , FL , USA
| |
Collapse
|
26
|
Chauhan NS, Ahluwalia A, Sharma YP, Thakur L. A Prospective Comparative Study of High Resolution Ultrasound and MRI in the Diagnosis of Rotator Cuff Tears in a Tertiary Hospital of North India. Pol J Radiol 2016; 81:491-497. [PMID: 27800039 PMCID: PMC5074798 DOI: 10.12659/pjr.897830] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2016] [Accepted: 03/15/2016] [Indexed: 11/20/2022] Open
Abstract
Background To evaluate the accuracy of high resolution ultrasound (USG) and MRI in the diagnosis of rotator cuff tears (RCT) and to determine if high resolution USG compares favorably in sensitivity and specificity to MRI in the diagnosis of rotator cuff injury. Material/Methods In this prospective comparative study, 40 patients with clinically suspected rotator cuff tears underwent both ultrasound and MRI of the shoulder. Out of these 40 patients, 31 patients who had positive findings for rotator cuff tears on ultrasound and/or MRI were finally included in the study while the remaining 9 patients with negative or unrelated findings were excluded. The USG and MRI were interpreted by two radiologists experienced in musculoskeletal radiology and blinded to findings of each other. Comparison was done using MRI as a standard reference. Results The agreement between USG and MRI for diagnosis of RCTs was statistically excellent; USG showed a sensitivity of 86.7% and a specificity of 100% for full-thickness tears, and a sensitivity of 89.7% and a specificity of 98.8% for partial-thickness tears; observed accuracy for full thickness tears was 98.4% and 95.9% for partial thickness tears. The Kappa coefficient of association was 0.91 for full thickness tears and 0.90 for partial thickness tears. Conclusions Considering the comparable diagnostic accuracy of USG and MRI, the former modality can be used as a first-line investigation for diagnosis of RCT. MRI should be used secondarily as a problem-solving tool either following an equivocal shoulder USG or for delineation of anatomy in cases where surgical correction is needed.
Collapse
Affiliation(s)
- Narvir Singh Chauhan
- Department of Radiology, Dr. Rajendra Prasad Government Medical College, Kangra, Himachal Pradesh, India
| | - Ajay Ahluwalia
- Department of Radiology, Dr. Rajendra Prasad Government Medical College, Kangra, Himachal Pradesh, India
| | - Yash Paul Sharma
- Department of Radiology, Dr. Rajendra Prasad Government Medical College, Kangra, Himachal Pradesh, India
| | - Lokesh Thakur
- Department of Orthopedics, Dr. Rajendra Prasad Government Medical College, Kangra, Himachal Pradesh, India
| |
Collapse
|
27
|
Hogaboom NS, Worobey LA, Boninger ML. Transfer Technique Is Associated With Shoulder Pain and Pathology in People With Spinal Cord Injury: A Cross-Sectional Investigation. Arch Phys Med Rehabil 2016; 97:1770-6. [DOI: 10.1016/j.apmr.2016.03.026] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2015] [Revised: 03/24/2016] [Accepted: 03/25/2016] [Indexed: 10/21/2022]
|
28
|
Lahham S, Becker B, Chiem A, Joseph LM, Anderson CL, Wilson SP, Subeh M, Trinh A, Viquez E, Fox JC. Pilot Study to Determine Accuracy of Posterior Approach Ultrasound for Shoulder Dislocation by Novice Sonographers. West J Emerg Med 2016; 17:377-82. [PMID: 27330675 PMCID: PMC4899074 DOI: 10.5811/westjem.2016.2.29290] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2015] [Revised: 01/10/2016] [Accepted: 02/12/2016] [Indexed: 11/27/2022] Open
Abstract
Introduction The goal of this study was to investigate the efficacy of diagnosing shoulder dislocation using a single-view, posterior approach point-of-care ultrasound (POCUS) performed by undergraduate research students, and to establish the range of measured distance that discriminates dislocated shoulder from normal. Methods We enrolled a prospective, convenience sample of adult patients presenting to the emergency department with acute shoulder pain following injury. Patients underwent ultrasonographic evaluation of possible shoulder dislocation comprising a single transverse view of the posterior shoulder and assessment of the relative positioning of the glenoid fossa and the humeral head. The sonographic measurement of the distance between these two anatomic structures was termed the Glenohumeral Separation Distance (GhSD). A positive GhSD represented a posterior position of the glenoid rim relative to the humeral head and a negative GhSD value represented an anterior position of the glenoid rim relative to the humeral head. We compared ultrasound (US) findings to conventional radiography to determine the optimum GhSD cutoff for the diagnosis of shoulder dislocation. Sensitivity, specificity, positive predictive value, and negative predictive value of the derived US method were calculated. Results A total of 84 patients were enrolled and 19 (22.6%) demonstrated shoulder dislocation on conventional radiography, all of which were anterior. All confirmed dislocations had a negative measurement of the GhSD, while all patients with normal anatomic position had GhSD>0. This value represents an optimum GhSD cutoff of 0 for the diagnosis of (anterior) shoulder dislocation. This method demonstrated a sensitivity of 100% (95% CI [82.4–100]), specificity of 100% (95% CI [94.5–100]), positive predictive value of 100% (95% CI [82.4–100]), and negative predictive value of 100% (95% CI [94.5–100]). Conclusion Our study suggests that a single, posterior-approach POCUS can diagnose anterior shoulder dislocation, and that this method can be employed by novice ultrasonographers, such as non-medical trainees, after a brief educational session. Further validation studies are necessary to confirm these findings.
Collapse
Affiliation(s)
- Shadi Lahham
- University of California Irvine, Department of Emergency Medicine, Orange, California
| | - Brent Becker
- Wellspan York Hospital, Department of Emergency Medicine, York, Pennsylvania
| | - Alan Chiem
- Olive View-UCLA Medical Center, Department of Emergency Medicine, Los Angeles, California
| | - Linda M Joseph
- University of California Irvine, Department of Emergency Medicine, Orange, California
| | - Craig L Anderson
- University of California Irvine, Department of Emergency Medicine, Orange, California
| | - Sean P Wilson
- University of California Irvine, Department of Emergency Medicine, Orange, California
| | - Mohammad Subeh
- University of California Irvine, Department of Emergency Medicine, Orange, California
| | - Alex Trinh
- University of California Irvine, Department of Emergency Medicine, Orange, California
| | - Eric Viquez
- University of California Irvine, Department of Emergency Medicine, Orange, California
| | - John C Fox
- University of California Irvine, Department of Emergency Medicine, Orange, California
| |
Collapse
|
29
|
Mohamed RE, Amin MA, Aboelsafa AA. Ultrasonographic and clinical study of post-stroke painful hemiplegic shoulder. THE EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE 2014. [DOI: 10.1016/j.ejrnm.2014.06.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
|
30
|
Ultrasound dimensions of the rotator cuff in young healthy adults. J Shoulder Elbow Surg 2014; 23:1107-12. [PMID: 24439247 DOI: 10.1016/j.jse.2013.11.012] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/05/2013] [Revised: 10/29/2013] [Accepted: 11/06/2013] [Indexed: 02/01/2023]
Abstract
BACKGROUND No studies have looked at the rotator cuff dimensions in the young healthy population using ultrasonography. Our aim is to define the ultrasound dimensions of the rotator cuff in the healthy young adult population and explore correlations with other patient characteristics. METHODS Thirty male and 30 female healthy volunteers (aged 18-40 years), with no shoulder problems, underwent ultrasound assessment of both shoulders by a musculoskeletal radiologist. The dimensions of the rotator cuff, deltoid, and biceps were measured in a standardized manner. RESULTS A total of 120 shoulders were scanned. The mean maximum width of the supraspinatus footprint was 14.9 mm in men and 13.5 mm in women (P < .001). The mean thickness of the supraspinatus tendon was 4.9 mm in women and 5.6 mm in men. The mean thickness of the subscapularis was 4.4 in men and 3.8 mm in women and for the infraspinatus was 4.9 mm in men and 4.4 mm in women. There was no correlation between height, weight, biceps, or deltoid thickness with any tendon measurements. Apart from supraspinatus tendon thickness, the difference between dominant and nondominant shoulders in the same sex was not significant for any other tendon dimensions. CONCLUSION This study has defined the dimensions of the rotator cuff in the young healthy adult, which has not been previously published. This is important for the documentation of normal ultrasound anatomy of the rotator cuff and also demonstrates that the asymptomatic contralateral shoulder can and should be used to estimate the expected dimensions.
Collapse
|
31
|
Lin HY, Wong PK, Ho WP, Chuang TY, Liao YS, Wong CC. Clavicular hook plate may induce subacromial shoulder impingement and rotator cuff lesion--dynamic sonographic evaluation. J Orthop Surg Res 2014; 9:6. [PMID: 24502688 PMCID: PMC3922330 DOI: 10.1186/1749-799x-9-6] [Citation(s) in RCA: 103] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/20/2013] [Accepted: 01/28/2014] [Indexed: 01/28/2023] Open
Abstract
Background Clavicular hook plates are effective fixation devices for distal clavicle fractures and severe acromioclavicular joint dislocations. However, increasing number of studies has revealed that subacromial portion of the hook may induce acromial bony erosion, shoulder impingement, or even rotator cuff damage. By sonographic evaluation, we thus intended to determine whether the presence of hook plate may induce subacromial shoulder impingement and its relationship relative to surrounding subacromial structures. Methods We prospectively followed 40 patients with either distal clavicle fracture or acromioclavicular joint dislocation that had surgery using the Arbeitsgemeinschaft für Osteosynthesefragen (AO) clavicular hook plate. All patients were evaluated by monthly clinical and radiographic examinations. Static and dynamic musculoskeletal sonography examinations were performed at final follow-up before implant removal. Clinical results for pain, shoulder function, and range of motion were evaluated using Constant-Murley and Disability of Arm, Shoulder, and Hand (DASH) scores. Results Clinically, 15 out of 40 patients (37.5%) presented with subacromial impingement syndrome and their functional scores were poorer than the non-impinged patients. Among them, six patients were noted to have rotator cuff lesion. Acromial erosion caused by hook pressure developed in 20 patients (50%). Conclusions We demonstrated by musculoskeletal sonography that clavicular hook plate caused subacromial shoulder impingement and rotator cuff lesion. The data also suggest an association between hardware-induced impingement and poorer functional scores. To our knowledge, the only solution is removal of the implant after bony consolidation/ligamentous healing has taken place. Thus, we advocate the removal of the implant as soon as bony union and/or ligamentous healing is achieved.
Collapse
Affiliation(s)
| | | | | | | | | | - Chin-Chean Wong
- Department of Orthopaedic Surgery, Wan Fang Hospital, Taipei Medical University, No, 111, Sec, 3, Xinglong Road, Taipei 11696, Taiwan.
| |
Collapse
|
32
|
Filipović K, Subin-Teodosijević S, Zvekić- Svorcan J, Tomašević-Todorović S. COMPARISON BETWEEN ULTRASONOGRAPHY RESULTS AND RESULTS OF MAGNETIC RESONANCE IN SHOULDER PATHOLOGY – CASE REPORT. ACTA MEDICA MEDIANAE 2013. [DOI: 10.5633/amm.2013.0407] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
|
33
|
Lenza M, Buchbinder R, Takwoingi Y, Johnston RV, Hanchard NCA, Faloppa F. Magnetic resonance imaging, magnetic resonance arthrography and ultrasonography for assessing rotator cuff tears in people with shoulder pain for whom surgery is being considered. Cochrane Database Syst Rev 2013; 2013:CD009020. [PMID: 24065456 PMCID: PMC6464715 DOI: 10.1002/14651858.cd009020.pub2] [Citation(s) in RCA: 90] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
BACKGROUND Shoulder pain is a very common symptom. Disorders of the rotator cuff tendons due to wear or tear are among the most common causes of shoulder pain and disability. Magnetic resonance imaging (MRI), magnetic resonance arthrography (MRA) and ultrasound (US) are increasingly being used to assess the presence and size of rotator cuff tears to assist in planning surgical treatment. It is not known whether one imaging method is superior to any of the others. OBJECTIVES To compare the diagnostic test accuracy of MRI, MRA and US for detecting any rotator cuff tears (i.e. partial or full thickness) in people with suspected rotator cuff tears for whom surgery is being considered. SEARCH METHODS We searched the Cochrane Register of Diagnostic Test Accuracy Studies, MEDLINE, EMBASE, and LILACS from inception to February 2011. We also searched trial registers, conference proceedings and reference lists of articles to identify additional studies. No language or publication restrictions were applied. SELECTION CRITERIA We included all prospective diagnostic accuracy studies that assessed MRI, MRA or US against arthroscopy or open surgery as the reference standard, in people suspected of having a partial or full thickness rotator cuff tear. We excluded studies that selected a healthy control group, or participants who had been previously diagnosed with other specific causes of shoulder pain such as osteoarthritis or rheumatoid arthritis. Studies with an excessively long period (a year or longer) between the index and reference tests were also excluded. DATA COLLECTION AND ANALYSIS Two review authors independently extracted data on study characteristics and results of included studies, and performed quality assessment according to QUADAS criteria. Our unit of analysis was the shoulder. For each test, estimates of sensitivity and specificity from each study were plotted in ROC space and forest plots were constructed for visual examination of variation in test accuracy. Meta-analyses were performed using the bivariate model to produce summary estimates of sensitivity and specificity. We were unable to formally investigate potential sources of heterogeneity because of the small number of studies. MAIN RESULTS We included 20 studies of people with suspected rotator cuff tears (1147 shoulders), of which six evaluated MRI and US (252 shoulders), or MRA and US (127 shoulders) in the same people. Many studies had design flaws, with the potential for bias, thus limiting the reliability of their findings. Overall, the methodological quality of the studies was judged to be low or unclear. For each test, we observed considerable heterogeneity in study results, especially between studies that evaluated US for the detection of full thickness tears and studies that evaluated MRA for the detection of partial thickness tears. The criteria for a positive diagnostic test (index tests and reference standard) varied between studies.Meta-analyses were not possible for studies that assessed MRA for detection of any rotator cuff tears or partial thickness tears. We found no statistically significant differences in sensitivity or specificity between MRI and US for detecting any rotator cuff tears (P = 0.13), or for detecting partial thickness tears (P = 1.0). Similarly, for the comparison between MRI, MRA and US for detecting full thickness tears, there was no statistically significant difference in diagnostic performance (P = 0.7). For any rotator cuff tears, the summary sensitivity and specificity were 98% (95% CI 92% to 99%) and 79% (95% CI 68% to 87%) respectively for MRI (6 studies, 347 shoulders), and 91% (95% CI 83% to 95%) and 85% (95% CI 74% to 92%) respectively for US (13 studies, 854 shoulders). For full thickness tears, the summary sensitivity and specificity were 94% (95% CI 85% to 98%) and 93% (95% CI 83% to 97%) respectively for MRI (7 studies, 368 shoulders); 94% (95% CI 80% to 98%) and 92% (95% CI 83% to 97%) respectively for MRA (3 studies, 183 shoulders); and 92% (95% CI 82% to 96%) and 93% (95% CI 81% to 97%) respectively for US (10 studies, 729 shoulders).Because few studies were direct head-to-head comparisons, we could not perform meta-analyses restricted to these studies. The test comparisons for each of the three classifications of the target condition were therefore based on indirect comparisons which may be prone to bias due to confounding. AUTHORS' CONCLUSIONS MRI, MRA and US have good diagnostic accuracy and any of these tests could equally be used for detection of full thickness tears in people with shoulder pain for whom surgery is being considered. The diagnostic performance of MRI and US may be similar for detection of any rotator cuff tears. However, both MRI and US may have poor sensitivity for detecting partial thickness tears, and the sensitivity of US may be much lower than that of MRI. The strength of evidence for all test comparisons is limited because most studies were small, heterogeneous and methodologically flawed, and there were few comparative studies. Well designed studies that directly compare MRI, MRA and US for detection of rotator cuff tears are needed.
Collapse
Affiliation(s)
- Mário Lenza
- Hospital Israelita Albert EinsteinOrthopaedic and Trauma DepartmentAv. Albert Einstein, 627/701São PauloSao PauloBrazilCEP 05651‐901
| | - Rachelle Buchbinder
- Department of Epidemiology and Preventive Medicine, School of Public Health and Preventive Medicine, Monash UniversityMonash Department of Clinical Epidemiology, Cabrini HospitalSuite 41, Cabrini Medical Centre183 Wattletree RoadMalvernVictoriaAustralia3144
| | - Yemisi Takwoingi
- University of BirminghamPublic Health, Epidemiology and BiostatisticsEdgbastonBirminghamUKB15 2TT
| | - Renea V Johnston
- Department of Epidemiology and Preventive Medicine, School of Public Health and Preventive Medicine, Monash UniversityMonash Department of Clinical Epidemiology, Cabrini HospitalSuite 41, Cabrini Medical Centre183 Wattletree RoadMalvernVictoriaAustralia3144
| | - Nigel CA Hanchard
- Teesside UniversityHealth and Social Care InstituteMiddlesbroughTees ValleyUKTS1 3BA
| | - Flávio Faloppa
- Universidade Federal de São PauloDepartment of Orthopaedics and TraumatologyRua Borges Lagoa, 783‐5th FloorSão PauloSão PauloBrazil
| | | |
Collapse
|
34
|
Abstract
Shoulder ultrasound is consistently used in the assessment of rotator cuff and is as accurate as magnetic resonance imaging in the detection of rotator cuff tear. It can be used as a focused examination providing rapid, real-time diagnosis, and treatment in desired clinical situations. This article presents a simplified approach to scanning and image-guided intervention, and discusses common sonographically apparent shoulder pathologies.
Collapse
|
35
|
Yablon CM, Bedi A, Morag Y, Jacobson JA. Ultrasonography of the shoulder with arthroscopic correlation. Clin Sports Med 2013; 32:391-408. [PMID: 23773874 DOI: 10.1016/j.csm.2013.03.001] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
Ultrasonography is a well-established and widely accepted modality for the evaluation of rotator cuff tears and injury to the biceps brachii tendon. Ultrasonography and magnetic resonance imaging have comparable sensitivity and specificity for diagnosing both full-thickness and partial-thickness rotator cuff tears. This article addresses the ultrasonographic diagnosis of abnormalities of the rotator cuff, rotator interval, and biceps brachii, with magnetic resonance imaging and arthroscopic correlation. Characteristic ultrasonographic findings as well as imaging pitfalls are reviewed.
Collapse
Affiliation(s)
- Corrie M Yablon
- Department of Radiology, University of Michigan, 1500 East Medical Center Drive, Ann Arbor, MI 48109, USA.
| | | | | | | |
Collapse
|
36
|
Mistieri MLA, Wigger A, Canola JC, Filho JGP, Kramer M. Ultrasonographic Evaluation of Canine Supraspinatus Calcifying Tendinosis. J Am Anim Hosp Assoc 2012; 48:405-10. [DOI: 10.5326/jaaha-ms-5818] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Supraspinatus calcifying tendinosis is an uncommon finding in dogs. Although its radiographic appearance has been described previously, radiographs alone do not provide detailed information about the tendon parenchyma. Tendon ultrasonography has been widely applied for the diagnosis of human tendinosis, but it remains underused in dogs. This article reviews the ultrasonographic technique and variable appearance of canine supraspinatus calcifying tendinosis observed in 33 tendons. The ultrasonographic findings are described. The most common ultrasonographic finding was a hyperechoic area accompanied by distal acoustic shadowing. No relationship with bicipital tenosynovitis was found. A color Doppler examination was possible in only five of the tendons, revealing no blood flow in those tendons. There was evidence that the presence of a hypoechoic area surrounding the calcification was related to clinical signs of pain, suggesting an active inflammatory process. Ultrasonography was an excellent technique to evaluate lesions of the supraspinatus tendon and it revealed details not apparent on radiographs.
Collapse
Affiliation(s)
- Maria Ligia A. Mistieri
- Department of Veterinary Medicine, Pampa Federal University, Uruguaiana, Brazil (M.M.); Department of Veterinary Clinical Science, Clinic for Small Animal Surgery, Justus Liebig University of Giessen, Ludwigstrasse, Germany (A.W., M.K.); and Department of Veterinary Clinics and Surgery, Sao Paulo State University, Jaboticabal, Brazil (J.C., J.F.)
| | - Antje Wigger
- Department of Veterinary Medicine, Pampa Federal University, Uruguaiana, Brazil (M.M.); Department of Veterinary Clinical Science, Clinic for Small Animal Surgery, Justus Liebig University of Giessen, Ludwigstrasse, Germany (A.W., M.K.); and Department of Veterinary Clinics and Surgery, Sao Paulo State University, Jaboticabal, Brazil (J.C., J.F.)
| | - Julio C. Canola
- Department of Veterinary Medicine, Pampa Federal University, Uruguaiana, Brazil (M.M.); Department of Veterinary Clinical Science, Clinic for Small Animal Surgery, Justus Liebig University of Giessen, Ludwigstrasse, Germany (A.W., M.K.); and Department of Veterinary Clinics and Surgery, Sao Paulo State University, Jaboticabal, Brazil (J.C., J.F.)
| | - João G. P. Filho
- Department of Veterinary Medicine, Pampa Federal University, Uruguaiana, Brazil (M.M.); Department of Veterinary Clinical Science, Clinic for Small Animal Surgery, Justus Liebig University of Giessen, Ludwigstrasse, Germany (A.W., M.K.); and Department of Veterinary Clinics and Surgery, Sao Paulo State University, Jaboticabal, Brazil (J.C., J.F.)
| | - Martin Kramer
- Department of Veterinary Medicine, Pampa Federal University, Uruguaiana, Brazil (M.M.); Department of Veterinary Clinical Science, Clinic for Small Animal Surgery, Justus Liebig University of Giessen, Ludwigstrasse, Germany (A.W., M.K.); and Department of Veterinary Clinics and Surgery, Sao Paulo State University, Jaboticabal, Brazil (J.C., J.F.)
| |
Collapse
|
37
|
Farshad M, Jundt-Ecker M, Sutter R, Schubert M, Gerber C. Does subacromial injection of a local anesthetic influence strength in healthy shoulders?: a double-blinded, placebo-controlled study. J Bone Joint Surg Am 2012; 94:1751-5. [PMID: 23032585 DOI: 10.2106/jbjs.k.00855] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Subacromial injection of a local anesthetic is used to eliminate pain as a confounding factor in clinical assessment of abduction strength in shoulders with a suspected rotator cuff tear. If strength remains diminished despite pain relief, a rotator cuff tear is likely. The effect of injecting local anesthetic into the subacromial space on the strength of a normal shoulder is unknown, although it could affect strength by impairing suprascapular or axillary nerve function. We hypothesized that subacromial injection of a local anesthetic could decrease shoulder abduction and/or external rotation strength, resulting in physical examination findings that could mislead the clinician. METHODS A double-blinded, randomized, placebo-controlled design was used to evaluate the effect of subacromial injection of lidocaine on shoulder strength in ten healthy male volunteers. The contralateral shoulder served as the placebo control for each treated shoulder. Abduction and external rotation strength measurements and electromyographic assessment were performed before and after the subacromial injection. Ultrasonography was used to verify the integrity of the rotator cuff and to document the distribution pattern of the injected local anesthetic. RESULTS The injection was subacromial in eighteen (90%) of twenty shoulders. There was no significant difference in pain or electromyographic parameters between shoulders injected with lidocaine and those injected with 0.9% saline solution (p > 0.05). In the Whipple position, placebo injection into the subacromial space decreased strength significantly compared with the pre-injection state (95 ± 17 to 84 ± 20 N, p = 0.012), whereas a similar decrease observed in the lidocaine group did not reach significance (97 ± 15 to 87 ± 14 N, p = 0.092). In 90° of abduction in the scapular plane (supraspinatus test position), there was no significant decrease in strength in either group. CONCLUSIONS Subacromial injection reached the subacromial bursa in most cases (90%) without radiographic guidance. The injection of a local anesthetic into the subacromial bursa had no relevant effect on shoulder strength and did not falsify the clinical assessment of strength. LEVEL OF EVIDENCE Diagnostic Level I. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Mazda Farshad
- Department of Orthopedic Surgery, Balgrist University Hospital, Forchstrasse 340, 8008 Zürich, Switzerland.
| | | | | | | | | |
Collapse
|
38
|
Malanga GA, Chu SK, Ramirez Del Toro J, Karnaugh RD, Dentico R, Komaroff E. Sonographic Evaluation of Supraspinatus Cross-sectional Area in Collegiate Baseball Players. PM R 2012; 4:488-92. [DOI: 10.1016/j.pmrj.2012.02.002] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2011] [Revised: 02/02/2012] [Accepted: 02/03/2012] [Indexed: 10/28/2022]
|
39
|
Abstract
Rotator cuff pathology is a common cause of shoulder pain, and imaging plays a major role in the management of shoulder problems. General radiography may be useful as an initial screening test particularly in trauma and arthritis. Musculoskeletal ultrasound and magnetic resonance imaging are the most suitable modalities for the investigation of the rotator cuff, having high sensitivities and specificities for full-thickness tears. Musculoskeletal ultrasound and magnetic resonance imaging are less accurate in the detection of partial-thickness tears with greater observer variability. This article reviews the normal and pathologic imaging features of the rotator cuff and highlights the potential usefulness and limitations of various imaging modalities in the assessment of the tendon and the potential impact of imaging findings on clinical patient care.
Collapse
|
40
|
ACR Appropriateness Criteria® on Acute Shoulder Pain. J Am Coll Radiol 2011; 8:602-9. [DOI: 10.1016/j.jacr.2011.05.008] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2011] [Accepted: 05/26/2011] [Indexed: 11/20/2022]
|
41
|
Naqvi GA, Jadaan M, Harrington P. Accuracy of ultrasonography and magnetic resonance imaging for detection of full thickness rotator cuff tears. INTERNATIONAL JOURNAL OF SHOULDER SURGERY 2011; 3:94-7. [PMID: 20532011 PMCID: PMC2878704 DOI: 10.4103/0973-6042.63218] [Citation(s) in RCA: 54] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
Background: Rotator cuff problems are frequently seen by orthopedic surgeons and accurate diagnosis is essential for appropriate management. Value of the clinical assessment of a shoulder is often limited, therefore, imaging studies have important implications in the management of rotator cuff pathologies. Aim: The purpose of this retrospective study is to compare the accuracy of ultrasonography (US) and magnetic resonance imaging (MRI) for detection of full-thickness rotator cuff tears. Materials and Methods: We reviewed 91 consecutive cases of shoulder arthroscopy and open rotator cuff repair, who had undergone preoperative investigation in the form of either an ultrasound or MRI. Thirty-six patients had an ultrasound and 55 had an MRI for their affected shoulders. We compared the accuracy of US and MRI for detection of full-thickness rotator cuff tears, using the operative findings as the ‘gold standard’. Data regarding a supraspinatus tear was assessed for the purpose of this study. Results: Ultrasonography correctly diagnosed 15 out of 17 tears (sensitivity of 0.88). There were 17 true-negative and two false-positive ultrasounds (specificity of 0.89). MRI accurately identified 33 of the 36 tears (sensitivity of 0.91). There were 16 true-negative and three false-positive tears on MRI (specificity of 0.84). The positive predictive value (PPV) was 88% for US and 92% for MRI. The negative predictive value (NPV) was 89% for US and 84% for MRI. The overall accuracy of the ultrasound was 88.89% (95% confidence interval (CI) = 74.09 to 96.18) as compared to 89.09% (95% CI = 77.82% to 95.26%) for the MRI. Conclusion: Full-thickness rotator cuff tears can be identified using ultrasound and MRI with comparable accuracy. US being a dynamic study and better tolerated by the patient, can therefore be used as the first-line investigation for rotator cuff tear, where appropriate skills are available to reduce the waiting time and cost of investigation.
Collapse
|
42
|
Smith TO, Back T, Toms AP, Hing CB. Diagnostic accuracy of ultrasound for rotator cuff tears in adults: a systematic review and meta-analysis. Clin Radiol 2011; 66:1036-48. [PMID: 21737069 DOI: 10.1016/j.crad.2011.05.007] [Citation(s) in RCA: 106] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2010] [Revised: 05/04/2011] [Accepted: 05/14/2011] [Indexed: 02/06/2023]
Abstract
AIM To determine the diagnostic accuracy of ultrasound to detect partial and complete thickness rotator cuff tears based on all available clinical trials. MATERIALS AND METHODS An electronic search of databases registering published and unpublished literature was conducted. All diagnostic accuracy studies that directly compared the accuracy of ultrasound (the index test) to either arthroscopic or open surgical findings (the reference test) for rotator cuff tear were included. The methodological quality of each included study was assessed using the QUADAS form. When appropriate, pooled sensitivity and specificity analysis was conducted, with an assessment of the summary receiver operating characteristic (ROC) curve for each analysis. RESULTS Sixty-two studies assessing 6007 patients and 6066 shoulders were included. Ultrasonography had good sensitivity and specificity for the assessment of partial thickness (sensitivity 0.84; specificity 0.89), and full-thickness rotator cuff tears (sensitivity 0.96; specificity 0.93). However, the literature poorly described population characteristics, assessor blinding, and was based on limited sample sizes. The literature assessing transducer frequency was particularly small in size. CONCLUSION Ultrasonography is an appropriate radiological technique for the assessment of rotator cuff tears with an acceptable sensitivity and specificity. The diagnostic test accuracy of ultrasound is superior for the detection of full-thickness compared to partial-thickness cuff tears. Further study assessing the effect of transducer frequency is warranted.
Collapse
Affiliation(s)
- T O Smith
- Department of Physiotherapy, University of East Anglia, Norwich, UK.
| | | | | | | |
Collapse
|
43
|
Abstract
Ultrasound is used increasingly in the investigation of the rotator cuff. It is as accurate as magnetic resonance imaging in the detection of rotator cuff tears and the assessment of tear size and can demonstrate atrophy and fatty infiltration in the rotator cuff muscles. This article reviews the anatomy and technique of shoulder ultrasound, the ultrasound findings in rotator cuff disease, the accuracy of ultrasound and magnetic resonance imaging in the assessment of rotator cuff tears and the role of interventional ultrasound of the shoulder.
Collapse
Affiliation(s)
- Ian Beggs
- Department of Radiology, Royal Infirmary, Edinburgh, UK.
| |
Collapse
|
44
|
Abstract
The shoulder is the most common region to be evaluated with musculoskeletal ultrasound. The shoulder's complex anatomy enables an exceptional range of mobility at the expense of static stability. Consequently, the shoulder is susceptible to a multitude of traumatic and atraumatic injuries. This article presents an overview of shoulder anatomy, recommends a standardized approach to the sonographic shoulder evaluation, and discusses common sonographically apparent pathology of the shoulder.
Collapse
|
45
|
Ultrasound detection of rotator cuff tears: observer agreement related to increasing experience. AJR Am J Roentgenol 2011; 195:W440-6. [PMID: 21098177 DOI: 10.2214/ajr.10.4526] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE Ultrasound of the rotator cuff is considered to be operator-dependent with its accuracy being related to the operator's level of experience. This study was conducted to test the hypothesis that ultrasound performed by operators with different levels of experience will give nonreproducible results. SUBJECTS AND METHODS Two radiologists, one general radiologist with no experience in musculoskeletal ultrasound and one experienced musculoskeletal radiologist, independently performed ultrasound on 200 shoulders in 183 consecutive patients. Agreement was assessed. Cohen's kappa values with standard errors were calculated. In 71 patients the ultrasound findings could be related to surgical findings. RESULTS The diagnoses of full-thickness and partial-thickness rotator cuff tears were made with agreements of 98% (κ-value: 0.95 [standard error, 0.03]) and 90% (κ-value: 0.79 [0.05]), respectively. Agreement for full-thickness tears was constant; the agreement for partial-thickness tears improved from 80% to 98% in the last quarter of the study period. Based on the 71 patients who underwent shoulder surgery, sensitivity, specificity, and accuracy for detecting full-thickness tears by the experienced and general radiologists were 94%, 94%, and 94% and 89%, 91%, and 90%, respectively. Sensitivity, specificity, and accuracy for detecting partial-thickness tears by the experienced and general radiologists were 100%, 32%, and 57% and 84%, 35%, and 53%, respectively. CONCLUSION The hypothesis that ultrasound of the shoulder is operator-dependent and related to experience was refuted. In this study, there was excellent agreement for the detection of rotator cuff tears, which only slightly improved with the increasing experience of the general radiologist. Accuracy of rotator cuff tear detection was high and in accordance with the results in the literature.
Collapse
|
46
|
Clinical value of single versus composite provocative clinical tests in the assessment of painful shoulder. J Clin Rheumatol 2010; 16:105-8. [PMID: 20130480 DOI: 10.1097/rhu.0b013e3181cf8392] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
OBJECTIVES The aims of the present study were to investigate the clinical value of the provocative clinical tests and propose a composite index for the assessment of painful shoulder, using ultrasonography (US) as reference method. METHODS Two hundred three patients with painful shoulder underwent both clinical and US evaluations. The physical examination was carried out performing the Hawkins, Jobe, Patte, Gerber, and Speed tests. Each test was included in a composite index namely, SNAPSHOT (Simple Numeric Assessment of Pain by SHOulder Tests). The US examination was performed by a rheumatologist experienced in US and blinded to clinical findings. Sensitivity, specificity, positive and negative predictive values, positive and negative likelihood ratio of each clinical test were calculated. The receiver operating characteristic (ROC) curve analysis was used to assess the performance of the composite SNAPSHOT index. RESULTS Sensitivity was low for the clinical diagnosis of all shoulder abnormalities. The highest sensitivity and smallest negative likelihood ratio were found for the Hawkins (63.88% and 0.50%) and Patte (62.21% and 0.52%) tests. Specificity was good for Speed (76.33%), Gerber (75.42%), and Patte (74.20%) tests. Patte and Speed tests were the most accurate (71.12% and 66.41%, respectively). The calculated area under the ROC curve related to the SNAPSHOT composite index was 0.881 +/- 0.026. With an optimal cut-off point of 3, the sensitivity and specificity were 75.8% and 87.5%, respectively. CONCLUSION The results of the present study showed that SNAPSHOT is a feasible, informative and quantitative composite index for the assessment of painful shoulder in the clinical setting.
Collapse
|
47
|
Abstract
Musculoskeletal ultrasound (US) can serve as an excellent imaging modality for the musculoskeletal clinician. Although MRI is more commonly ordered in the United States for musculoskeletal problems, both of these imaging modalities have advantages and disadvantages and can be viewed as complementary rather than adversarial. For diagnostic US, relative recent advances in technology have improved ultrasound’s ability to diagnose a myriad of musculoskeletal problems with enhanced resolution. The structures most commonly imaged with diagnostic musculoskeletal US, include tendon, muscle, nerve, joint, and some osseous pathology. This brief review article will discuss the role of US in imaging various common musculoskeletal disorders and will highlight, where appropriate, how recent technological advances have improved this imaging modality in musculoskeletal medicine. Additionally, clinicians practicing musculoskeletal medicine should be aware of the ability as well as limitations of this unique imaging modality and become familiar with conditions where US may be more advantageous than MRI.
Collapse
Affiliation(s)
- Paul H Lento
- Rehabilitation Institute of Chicago, Chicago, USA.
| | | |
Collapse
|
48
|
Ultrasound in American Rheumatology Practice: Report of the American College of Rheumatology Musculoskeletal Ultrasound Task Force. Arthritis Care Res (Hoboken) 2010; 62:1206-19. [DOI: 10.1002/acr.20241] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
|
49
|
Schreinemachers SA, van der Hulst VPM, Willems WJ, Bipat S, van der Woude HJ. Detection of partial-thickness supraspinatus tendon tears: is a single direct MR arthrography series in ABER position as accurate as conventional MR arthrography? Skeletal Radiol 2009; 38:967-75. [PMID: 19294377 PMCID: PMC2733185 DOI: 10.1007/s00256-009-0680-3] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/31/2008] [Revised: 02/23/2009] [Accepted: 03/01/2009] [Indexed: 02/02/2023]
Abstract
PURPOSE The purpose of this study was to retrospectively evaluate sensitivity and specificity of a single magnetic resonance (MR) arthrography series in abduction external rotation (ABER) position compared with conventional MR arthrography for detection of supraspinatus tendon tears, with arthroscopy as gold standard, and to assess interobserver variability. MATERIALS AND METHODS Institutional review board approval was obtained; informed consent was waived. MR arthrograms of 250 patients (170 men and 80 women; mean age, 36 years) were retrospectively and independently evaluated by three observers. Oblique coronal T1-weighted fat-suppressed images, proton density, and T2-weighted images and axial T1-weighted images and oblique sagittal T1-weighted fat-suppressed images were analyzed to detect supraspinatus tendon tears. Separately, a single T1-weighted fat-suppressed oblique axial series in ABER position was evaluated. Both protocols were scored randomly without knowledge of patients' clinical history and arthroscopy results. Tears were subclassified, based on articular surface integrity and extension (Lee classification). Interobserver agreement was assessed by kappa statistics for all patients. Ninety-two of 250 patients underwent arthroscopy; sensitivity and specificity of ABER and conventional MR arthrography were calculated and compared using paired McNemar test. RESULTS Weighted kappa values of ABER and conventional MR arthrography were 0.48-0.65 and 0.60-0.67, respectively. According to arthroscopy, 69 of 92 patients had an intact cuff, and 23 patients had a cuff tear (16 partial thickness and seven full thickness). There were no statistically significant differences between ABER and conventional MR arthrography regarding sensitivity (48-61% and 52-70%, respectively) and specificity (80-94% and 91-95%). CONCLUSION Sensitivity and specificity of a single T1-weighted series in ABER position and conventional MR arthrography are comparable for assessment of rotator cuff tears.
Collapse
|
50
|
|