1
|
Park MH, Lim W, Jo D, Jung JS, Kim S, Kim J, Lim HS, Lee JS, Min JJ, Hyun H. Rapid Differential Diagnosis of Breast Microcalcification Using Targeted Near-Infrared Fluorophores. Adv Healthc Mater 2018; 7:e1701062. [PMID: 29210533 DOI: 10.1002/adhm.201701062] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2017] [Revised: 10/15/2017] [Indexed: 11/06/2022]
Abstract
Early detection and differential diagnosis of breast microcalcifications are of significant importance in effective treatment of early breast cancer, because mineral composition of breast calcification is directly associated with different pathological states. However, applying image-based modalities for component identification in breast calcification remains challenging, because no calcification-specific contrast agent is available to distinguish between benign and malignant (type I and type II, respectively) calcifications of breast lesions. In this study, real-time near-infrared (NIR) fluorescence imaging of breast microcalcifications using targeted NIR fluorophores in combination with dual-channel NIR fluorescence imaging system is reported. This strategy can be used to solve major problem in mammography and ultrasonography methods for the differentiation of benign and malignant microcalcifications. Thus, this novel technology shows significant potential for breast cancer diagnosis and image-guided surgery performed with increased precision and efficiency by providing differential diagnosis of breast microcalcifications.
Collapse
Affiliation(s)
- Min Ho Park
- Department of Surgery; Chonnam National University Medical School; Gwangju 61469 South Korea
| | - Wonbong Lim
- Department of Premedical Program; School of Medicine; Chosun University; Gwangju 61452 South Korea
| | - Danbi Jo
- Department of Biomedical Sciences; Chonnam National University Medical School; Gwangju 61469 South Korea
| | - Jin Seok Jung
- Department of Biomedical Sciences; Chonnam National University Medical School; Gwangju 61469 South Korea
| | - Subin Kim
- Department of Biomedical Sciences; Chonnam National University Medical School; Gwangju 61469 South Korea
| | - Jangho Kim
- Department of Rural and Biosystems Engineering; Chonnam National University; Gwangju 61186 South Korea
| | - Hyo Soon Lim
- Department of Radiology; Chonnam National University Medical School; Gwangju 61469 South Korea
| | - Ji Shin Lee
- Department of Pathology; Chonnam National University Medical School; Gwangju 61469 South Korea
| | - Jung-Joon Min
- Department of Nuclear Medicine; Chonnam National University Medical School; Gwangju 61469 South Korea
| | - Hoon Hyun
- Department of Biomedical Sciences; Chonnam National University Medical School; Gwangju 61469 South Korea
| |
Collapse
|
2
|
Raj SD, Sedgwick EL, Severs FJ, Hilsenbeck SG, Wang T, Sepulveda KA. Stereotactic Biopsy of Segmental Breast Calcifications: Is Sampling of Anterior and Posterior Components Necessary? Acad Radiol 2016; 23:682-6. [PMID: 27052522 DOI: 10.1016/j.acra.2015.12.025] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2015] [Revised: 12/05/2015] [Accepted: 12/11/2015] [Indexed: 10/22/2022]
Abstract
RATIONALE AND OBJECTIVES Core needle biopsy results of segmental calcifications on mammography can have direct impact on surgical management. Although dependent on breast size, cancer spanning greater than 5 cm is usually treated with mastectomy, and cancer less than 5 cm is managed with lumpectomy. Approach to stereotactic biopsy of morphologically similar segmental calcifications that span more than 5 cm on mammography varies geographically and is currently largely based on preference of the surgical or medical oncology colleagues. Some clinicians prefer biopsy of the anterior and posterior aspects of the abnormality, whereas others believe a single biopsy within the abnormality is adequate. There is insufficient data to support whether a single biopsy of calcifications is adequate to establish the need for mastectomy, or if pathology-proven cancer in the anterior and posterior components to define the extent of disease is required. This study aims to evaluate concordance rates of paired biopsies of suspicious segmental mammographic calcifications. MATERIALS AND METHODS From a 5-year review of our imaging database, 32 subjects were identified with breast imaging reporting and data system (BI-RADS) 4 or 5 segmental calcifications on mammography who underwent anterior and posterior stereotactic biopsies. The paired biopsy results were independently analyzed for concordance on benign, high-risk, or malignant pathology. RESULTS Of the 32 cases, there was perfect agreement (32/32 cases = 100% concordance, 95% confidence interval = 89.3-100%) in anterior and posterior pairs in benign, high-risk, or malignant findings (kappa = 1, P < 0.001). CONCLUSIONS The absence of data on pathological concordance in anterior and posterior aspects of suspicious, morphologically similar, segmental calcifications spanning 5 cm or more has led to a varied clinical approach to stereotactic biopsy. The 100% rate of pathological concordance in our study suggests that a single biopsy is adequate for diagnosis and representative of the whole mammographic abnormality. Implementation of this approach will potentially reduce unnecessary biopsies and surgeries, minimize healthcare costs, and decrease patient morbidity.
Collapse
|
3
|
Youn I, Kim MJ, Moon HJ, Kim EK. Absence of Residual Microcalcifications in Atypical Ductal Hyperplasia Diagnosed via Stereotactic Vacuum-Assisted Breast Biopsy: Is Surgical Excision Obviated? J Breast Cancer 2014; 17:265-9. [PMID: 25320625 PMCID: PMC4197357 DOI: 10.4048/jbc.2014.17.3.265] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2014] [Accepted: 08/23/2014] [Indexed: 11/30/2022] Open
Abstract
PURPOSE The purpose of our study was to evaluate the underestimation rate of atypical ductal hyperplasia (ADH) on vacuum-assisted breast biopsy (VABB), and to examine the correlation between residual microcalcifications and the underestimation rate of ADH. METHODS A retrospective study was performed on 27 women (mean age, 49.2±9.2 years) who underwent additional excision for ADH via VABB for microcalcifications observed by using mammography. The mammographic findings, histopathologic diagnosis of all VABB and surgical specimens, and association of malignancy with residual microcalcifications were evaluated. The underestimation rate of ADH was also calculated. RESULTS Of the 27 women with microcalcifications, nine were upgraded to ductal carcinoma in situ (DCIS); thus, the underestimation rate was 33.3% (9/27). There was no difference in age (p=0.40) and extent of microcalcifications (p=0.10) when comparing benign and malignant cases. Six of 17 patients (35.3%) with remaining calcifications after VABB were upgraded to DCIS, and three of 10 patients (30%) with no residual calcifications after VABB were upgraded (p=1.00). CONCLUSION The underestimation rate of ADH on VABB was 33.3%. Furthermore, 30% of patients with no remaining calcifications were upgraded to DCIS. Therefore, we conclude that all ADH cases diagnosed via VABB should be excised regardless of the presence of residual microcalcifications.
Collapse
Affiliation(s)
- Inyoung Youn
- Department of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Min Jung Kim
- Department of Radiology, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul, Korea
| | - Hee Jung Moon
- Department of Radiology, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul, Korea
| | - Eun-Kyung Kim
- Department of Radiology, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul, Korea
| |
Collapse
|
4
|
Ahmadinejad N, Movahedinia S, Movahedinia S, Shahriari M. Association of mammographic density with pathologic findings. IRANIAN RED CRESCENT MEDICAL JOURNAL 2013; 15:e16698. [PMID: 24693404 PMCID: PMC3955519 DOI: 10.5812/ircmj.16698] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 02/22/2013] [Revised: 06/25/2013] [Accepted: 08/27/2013] [Indexed: 01/10/2023]
Abstract
Background Breast cancer is one of the most common cancers in the world and is the first cause of death due to cancer among women. Mammography is the best screening method and mammographic density, which determines the percentage of fibro glandular tissue of breast, is one of the strongest risk factors of breast cancer. Because benign and malignant lesions may present as dense lesions in mammography so it is necessary to take a core biopsy of any suspicious lesions to evaluate pathologic findings. Objectives The aim of this study was to assess the association between mammographic density and histopathological findings in Iranian population. Moreover, we assessed the correlation between mammographic density and protein expression profile. We indeed, determined the accuracy and positive predictive value and negative predictive value of mammographic reports in our center. Patients and Method This study is a cross-sectional study carried out among 131 eligible women who had referred to imaging center for mammographic examination and had been advised to take biopsy of breast tissue. All participants of the study had filled out the informed consent. Pathologic review was performed blinded to the density status. Patients were divided into low density breast tissue group (ACR density group 1-2) and high density breast tissue group (ACR 3, 4) and data was compared between these two groups. Statistical analysis performed using SPSS for windows, version 11.5. We used chi-square, t-test, and logistic regression test for analysis and Odds Ratio calculated where indicated. Results In patients with high breast densities, malignant cases (61.2%) were significantly more in comparison to patients with low breast densities (37.3%) (P= 0.007, OR=2.66 95% CI=1.29-5.49). After adjusting for age, density was associated with malignancy in age groups <46 years (P=0.007), and 46-60 years (P=0.024) but not in age group >60yrs (P=0.559). Adjusting for menopausal status, density showed association with malignancy in both pre-menopause (P=0.041) and menopause (P=0.010) patients. Using logistic regression test, only age and density showed independent association with risk of breast cancer. No association was found between density and protein profile expression. Mammographic method has a false negative percent of 10.3% for negative BI-RADS group and a Positive Predictive Value (PPV) of 69.6% for positive BI-RADS group. PPVs for BI-RADS 4a, 4b, 4c and 5 were 16%, 87.5%, 84.6%, and 91.5% respectively. NPVs for BI-RADS 1, 2 and 3 were 66.7%, 95.8% and 90.0% respectively. Conclusions In this study we found that increasing in mammographic density is associated with an increase in malignant pathology reports. Expression of ER, PR and HER-2 receptors didn't show association with density. Our mammographic reports had a sensitivity of 94.1% and a specificity of 55.6%, which shows that our mammography is an acceptable method for screening breast cancer in this center.
Collapse
Affiliation(s)
- Nasrin Ahmadinejad
- Advanced Diagnostic and Interventional Radiology Research Center (ADIR), Tehran University of Medical Sciences (TUMS), Tehran, IR Iran
| | - Samaneh Movahedinia
- School of Medicine, Tehran University of Medical Sciences (TUMS), Tehran, IR Iran
| | - Sajjadeh Movahedinia
- School of Medicine, Tehran University of Medical Sciences (TUMS), Tehran, IR Iran
- Corresponding Author: Sajjadeh Movahedinia, Advanced Diagnostic and Interventional Radiology Research Center (ADIR), Tehran University of Medical Sciences (TUMS), Imam Khomeini Hospital, Tehran, Iran. Tel: +98-2166581577, E-mail:
| | - Mona Shahriari
- School of Medicine, Tehran University of Medical Sciences (TUMS), Tehran, IR Iran
| |
Collapse
|
5
|
Microcalcifications Detected as an Abnormality on Screening Mammography: Outcomes and Followup over a Five-Year Period. Int J Breast Cancer 2013; 2013:458540. [PMID: 24194985 PMCID: PMC3806370 DOI: 10.1155/2013/458540] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2013] [Accepted: 08/17/2013] [Indexed: 11/17/2022] Open
Abstract
Objectives. This study reviewed the outcome of women attending a breast screening program recalled for assessment of microcalcifications and examined the incidence of a breast carcinoma detected during the following five years in any of the women who were given a benign diagnosis at assessment. Method. A retrospective study consisted of 235 clients attending an Australian BreastScreen program in 2003, who were recalled for investigation of microcalcifications detected on screening mammography. Records for the following five years were available for 168 women in the benign outcome group including those who did not require biopsy at initial assessment. Results. Malignant disease was detected in 26.0% (n = 146) of the women who underwent biopsy. None of the women in the benign outcome group, with available five-year follow-up records, developed a subsequent breast cancer, arising from the calcifications initially recalled in 2003. Conclusions. This study highlights the effectiveness of an Australian screening program in diagnosing malignancy in women with screen detected microcalcification. This has been achieved by correctly determining 38% (n = 235) of the women as benign without the need for biopsy or early recall. A low rate of open surgical biopsies was performed with no cancer diagnoses missed at the time of initial assessment.
Collapse
|
6
|
|
7
|
Hong ZJ, Chu CH, Fan HL, Hsu HM, Chen CJ, Chan DC, Yu JC. Factors predictive of breast cancer in open biopsy in cases with atypical ductal hyperplasia diagnosed by ultrasound-guided core needle biopsy. EUROPEAN JOURNAL OF SURGICAL ONCOLOGY 2011; 37:758-64. [PMID: 21764539 DOI: 10.1016/j.ejso.2011.06.014] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2011] [Revised: 06/19/2011] [Accepted: 06/27/2011] [Indexed: 10/17/2022]
Abstract
AIMS The purpose of the study was to explore factors predictive of breast cancer as diagnosed by excision biopsy in cases with a diagnosis of atypical ductal hyperplasia (ADH) on ultrasound-guided core needle biopsy (CNB). PATIENTS AND METHODS We carried out diagnosis of breast lesions by ultrasound-guided CNB in a single hospital in Taiwan from November 2003 to October 2009. Patients who were diagnosed with ADH and subsequently underwent excision biopsy were included in this study (n = 124). RESULTS Fifty-six of the 124 patients who were included (45.2%) had cancer, and the remaining 68 had benign lesions. By multivariate analysis of all clinical characteristics and on the basis of the imaging features in these cases, older patient age (≥50 y/o, OR: 3.910, p = 0.005), larger tumour size (≥15 mm, OR: 3.398, p = 0.013), and the presence of architectural distortion by mammography (OR: 10.7, p = 0.036) were found likely to be associated with breast cancer. CONCLUSIONS Open biopsy is necessary in patients who were diagnosed with ADH on CNB. Older patients (≥50 y/o), with a larger tumour size (≥15 mm) and an abnormal mammography are especially likely to have breast cancer.
Collapse
Affiliation(s)
- Z-J Hong
- General Surgery, Department of Surgery, Tri-Service General Hospital, National Defense Medical Center, 325, Sec 2, Chen-Kung Rd, Neihu, Taipei 114, Taiwan
| | | | | | | | | | | | | |
Collapse
|
8
|
Brennan ME, Turner RM, Ciatto S, Marinovich ML, French JR, Macaskill P, Houssami N. Ductal carcinoma in situ at core-needle biopsy: meta-analysis of underestimation and predictors of invasive breast cancer. Radiology 2011; 260:119-28. [PMID: 21493791 DOI: 10.1148/radiol.11102368] [Citation(s) in RCA: 264] [Impact Index Per Article: 20.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
PURPOSE To perform a meta-analysis to report pooled estimates for underestimation of invasive breast cancer (where core-needle biopsy [CNB] shows ductal carcinoma in situ [DCIS] and excision histologic examination shows invasive breast cancer) and to identify preoperative variables that predict invasive breast cancer. MATERIALS AND METHODS Studies were identified by searching MEDLINE and were included if they provided data on DCIS underestimates (overall and according to preoperative variables). Study-specific and pooled percentages for DCIS underestimates were calculated. By using meta-regression (random effects logistic modeling) the association between each study-level preoperative variable and understaged invasive breast cancer was investigated. RESULTS Fifty-two studies that included 7350 cases of DCIS with findings at excision histologic examination as the reference standard met the eligibility criteria and were included. There were 1736 underestimates (invasive breast cancer at excision); the random-effects pooled estimate was 25.9% (95% confidence interval: 22.5%, 29.5%). Preoperative variables that showed significant univariate association with higher underestimation included the use of a 14-gauge automated device (vs 11-gauge vacuum-assisted biopsy, P = .006), high-grade lesion at CNB (vs non-high grade lesion, P < .001), lesion size larger than 20 mm at imaging (vs lesions ≤ 20 mm, P < .001), Breast Imaging Reporting and Data System (BI-RADS) score of 4 or 5 (vs BI-RADS score of 3, P for trend = .005), mammographic mass (vs calcification only, P < .001), and palpability (P < .001). CONCLUSION About one in four DCIS diagnoses at CNB represent understaged invasive breast cancer. Preoperative variables significantly associated with understaging include biopsy device and guidance method, size, grade, mammographic features, and palpability.
Collapse
Affiliation(s)
- Meagan E Brennan
- Screening and Test Evaluation Program, School of Public Health, Sydney Medical School, University of Sydney, Edward Ford Building, Room A27, Sydney, NSW 2006, Australia.
| | | | | | | | | | | | | |
Collapse
|
9
|
Hahn SY, Shin JH, Han BK, Ko EY. Sonographically-guided vacuum-assisted biopsy with digital mammography-guided skin marking of suspicious breast microcalcifications: comparison of outcomes with stereotactic biopsy in Asian women. Acta Radiol 2011; 52:29-34. [PMID: 21498322 DOI: 10.1258/ar.2010.100289] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
BACKGROUND Management of suspicious microcalcifications in very thin breasts is problematic. PURPOSE To evaluate whether sonographically-guided vacuum-assisted biopsy (USVAB) with digital mammography-guided skin marking (DM) for the diagnosis of breast microcalcifications is comparable to stereotactic-guided vacuum-assisted biopsy (SVAB) in Asian women with thin breasts. MATERIAL AND METHODS Retrospective review was performed for 263 consecutive suspicious microcalcification lesions in 261 women who underwent USVAB with DM or SVAB using a prone table between January 2004 and December 2007. SVAB was performed for 190 lesions and USVAB for 73 lesions. Biopsy results were correlated with surgical pathology or followed up for at least 12 months. The diagnostic outcomes of SVAB and USVAB to diagnose microcalcifications were compared. RESULTS Of 263 lesions, 104 (40%) underwent surgery and 159 (60%) were followed up. SVAB and USVAB groups showed similar final categories or the extent of microcalcifications. US visible lesions were 57 (78%) of 73 at USVAB and 14 (10%) of 140 at SVAB. Of 57 US visible lesions at USVAB, 29 (51%) were not found in initial US but were detectable with the help of DM. Specimen radiographs were negative in 2.1% of lesions at SVAB and in 4.1% at USVAB (p=0.4008). The under-estimation rate and false-negative rate were similar in SVAB and USVAB. CONCLUSION US with DM facilitates US visibility of microcalcifications. USVAB with DM can produce acceptable biopsy results, as can SVAB, to diagnose breast microcalcifications in patients with thin breasts.
Collapse
Affiliation(s)
- Soo Yeon Hahn
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul
- Department of Radiology, Gachon University Gil Hospital, Incheon, South Korea
| | - Jung Hee Shin
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul
| | - Boo-Kyung Han
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul
| | - Eun Young Ko
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul
| |
Collapse
|
10
|
Swamy R. Histological correlation of mammographically detected breast calcifications – A need for rational protocols. ACTA ACUST UNITED AC 2009. [DOI: 10.1016/j.mpdhp.2009.09.005] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
11
|
Cangiarella JF, Waisman J, Weg N, Tata M, Gross J, Symmans WF. The Use of Stereotaxic Core Biopsy and Stereotaxic Aspiration Biopsy as Diagnostic Tools in the Evaluation of Mammary Calcification. Breast J 2008; 6:366-372. [PMID: 11348394 DOI: 10.1046/j.1524-4741.2000.99095.x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
We compared stereotaxic fine needle aspiration biopsy (SFNA) with stereotaxic core needle biopsy (SCB) in the evaluation of radiographically clustered mammary microcalcification, a common finding at screening mammography. Over a 4-year period, 181 specimens were obtained from 175 patients who underwent both SFNA and SCB of clustered microcalcification. Aspiration and core biopsies were performed by radiologists at a community-based diagnostic radiology facility. All aspiration smears were air dried, stained on site, and assessed for adequacy by the radiologists, then sent to the cytopathologists at New York University for interpretation. Core biopsy specimens were formalin fixed, paraffin embedded, hematoxylin and eosin stained, and interpreted by surgical pathologists at a community hospital. Of 181 SFNA specimens, 133 (74%) were benign, 18 (10%) were atypical, 13 (7%) were suspicious, and 16 (9%) were malignant. One (0.5%) aspiration biopsy was nondiagnostic. Excisional biopsies were performed after 12 benign SFNAs and in 46 of the 47 cases with an atypical, suspicious, or malignant diagnosis on SFNA. Mammographic follow-up in 111 of the 133 cases (92%) diagnosed as benign showed no radiologic change (mean 29.2 months, range 6-60 months). The false-negative rate for cancer was 4% (6 cases) for SFNA alone. There were no false-positive diagnoses for SFNA. There was one false-positive diagnosis on core biopsy [focal cribriform ductal carcinoma in situ (DCIS)], which at excisional biopsy and correlation with the core biopsy was diagnosed as ductal hyperplasia; the false-negative rate for cancer was 8% (13 cases) for SCB alone. Aspiration biopsy identified calcification in 180 procedures, core needle biopsy revealed calcification in 170. SFNA was superior to SCB for the confirmation of clustered mammary microcalcification (99% versus 94%) and in the identification of cancer associated with microcalcification (false negative rate of 4% versus 8%). Patients with benign findings on stereotaxic aspiration and core biopsy can reasonably be followed mammographically.
Collapse
Affiliation(s)
- Joan F. Cangiarella
- Department of Pathology, New York University Medical Center, New York, New York; Noah Weg and Associates, Diagnostic Radiology, Suffern, New York; Good Samaritan Hospital, Suffern, New York, and Beth Israel Medical Center, New York, New York
| | | | | | | | | | | |
Collapse
|
12
|
Easley S, Abdul-Karim FW, Klein N, Wang N. Segregation of radiographic calcifications in stereotactic core biopsies of breast: is it necessary? Breast J 2007; 13:486-9. [PMID: 17760670 DOI: 10.1111/j.1524-4741.2007.00469.x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Stereotactic-needle core biopsy (SNCB) is increasingly being used for the evaluation of mammographic calcifications. Radiography of SNCB specimens is essential to confirm the presence of calcifications within the biopsy material. To aid and direct the pathologist, it has been recommended that SNCBs be separated into those with and without radiographic calcifications and separately embedded. However, the utility of this separation to the pathologist has not been established. We reviewed 80 consecutive 11 gauge vacuum-assisted SNCB procedures performed for mammographic calcifications. The core biopsies were separated by the radiologist into those with and without radiographic calcifications ("calcs" and "no calcs"). Twenty-nine of 80 (36%) of the "calcs" cores were atypical or malignant, while 23 of 80 (29%) of the "no calcs" cores were atypical or malignant (chi(2) = 0.63, p = NS). The same diagnosis was rendered in the "calcs" and "no calcs" specimens in 61/80 cases (76%). Two cases of ductal carcinoma in situ, four cases of atypical ductal hyperplasia and 13 cases of fibroadenoma were diagnosed in the "calcs" cores only. However, in all cases where the pathologic lesion was seen in the "calcs" core only, the pathologic lesion was present on initial H&E levels and would have been diagnosed even in the absence of core segregation. Deeper sections were deemed necessary in seven of the 80 cases. No change in diagnosis was made on the basis of these deeper sections, even in the cases where histologic calcifications appeared on deeper sections. Separate embedding of SNCBs into those with and without radiographic calcifications does not appear to be of great utility to the pathologist. Equal attention should be given to all cores in the setting of SNCBs for mammographic calcifications.
Collapse
Affiliation(s)
- Samantha Easley
- Department of Pathology, University Hospitals Case Medical Center, Cleveland, Ohio 44106, USA
| | | | | | | |
Collapse
|
13
|
Abstract
The use of ultrasound has grown tremendously since it was introduced in 1951. This article describes use of this modality in patients who have breast disease.
Collapse
Affiliation(s)
- Margaret Thompson
- Division of Breast Surgical Oncology, Department of Surgery, University of Arkansas for Medical Sciences, 4301 West Markham, Slot 725, Little Rock, AR 72205-7199, USA
| | | |
Collapse
|
14
|
Balleyguier C, Ayadi S, Van Nguyen K, Vanel D, Dromain C, Sigal R. BIRADS™ classification in mammography. Eur J Radiol 2007; 61:192-4. [PMID: 17164080 DOI: 10.1016/j.ejrad.2006.08.033] [Citation(s) in RCA: 113] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2006] [Revised: 08/21/2006] [Accepted: 08/24/2006] [Indexed: 10/23/2022]
Abstract
The Breast Imaging Report and Data System (BIRADS) of the American College of Radiology (ACR) is today largely used in most of the countries where breast cancer screening is implemented. It is a tool defined to reduce variability between radiologists when creating the reports in mammography, ultrasonography or MRI. Some changes in the last version of the BIRADStrade mark have been included to reduce the inaccuracy of some categories, especially for category 4. The BIRADStrade mark includes a lexicon and descriptive diagrams of the anomalies, recommendations for the mammographic report as well as councils and examples of mammographic cases. This review describes the mammographic items of the BIRADS classification with its more recent developments, while detailing the advantages and limits of this classification.
Collapse
Affiliation(s)
- Corinne Balleyguier
- Department of Radiology, Institut de Cancérologie Gustave-Roussy, 39 rue Camille Desmoulins, 94805 Villejuif, France.
| | | | | | | | | | | |
Collapse
|
15
|
Ciatto S, Houssami N, Ambrogetti D, Bianchi S, Bonardi R, Brancato B, Catarzi S, Risso GG. Accuracy and Underestimation of Malignancy of Breast Core Needle Biopsy: the Florence Experience of Over 4000 Consecutive Biopsies. Breast Cancer Res Treat 2006; 101:291-7. [PMID: 16823506 DOI: 10.1007/s10549-006-9289-6] [Citation(s) in RCA: 86] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2006] [Accepted: 05/24/2006] [Indexed: 11/26/2022]
Abstract
Breast core needle biopsy (CNB) is used for sampling breast lesions in both the screening and diagnostic context. We present the accuracy of breast CNB from a consecutive series of 4035 core biopsies, using methods that minimise selection and verification bias. We calculate accuracy and underestimation of malignancy for both automated (14G) and directional vacuum-assisted (11G) CNB performed under stereotactic or sonographic guidance. Overall sensitivity of CNB is 94.2% (92.9-95.5%) and specificity is 88.1% (86.6-89.6%), positive and negative predictive values are 84.8% (82.9-86.7%) and 95.6% (94.6-96.6%), respectively. In sampling microcalcification, the overall underestimation of malignancy is 26.6% (22.9-30.3%): underestimation is significantly higher for automated CB relative to VAB (chi2 ((df = 1)) = 8.90 , P = 0.002), the absolute difference in underestimation being 14% (5-23%); sensitivity is higher for VAB than automated CB (chi2 ((df = 1)) = 3.28, P = 0.06) but specificity is significantly higher for automated CB (14G) relative to VAB (11G) (chi2 ((df = 1)) = 6.37, P = 0.01), and the overall accuracy of the two methods is similar. Sensitivity of CNB improved with experience (over time and in relation to caseload). Accuracy was not substantially affected by lesion palpability or image-guidance method, and was similar for both masses and calcification but lower for lesions depicted as distortions on mammography. Inadequacy was very low and decreased with greater operator caseload, and was not associated with core gauge or image-guidance method. False negatives occurred in 4.4% (3.4-5.4%) of cases, and where core histology was benign but discordant with (suspicious) imaging and/or clinical findings the likelihood of malignancy was 33.1% (18.5-47.7%), emphasising the importance of correlating all test information in breast diagnosis.
Collapse
Affiliation(s)
- Stefano Ciatto
- Centro per lo Studio e la Prevenzione Oncologica (CSPO), Florence, Italy
| | | | | | | | | | | | | | | |
Collapse
|
16
|
Plantade R, Hammou JC, Fighiera M, Aubanel D, Scotto A, Gueret S. Sous-estimation du cancer du sein par les macrobiopsies stéréotaxiques 11-gauge assistées par le vide. IMAGERIE DE LA FEMME 2005. [DOI: 10.1016/s1776-9817(05)80640-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
17
|
Quelle prise en charge de l’hyperplasie canalaire atypique après biopsie stéréotaxique 11-gauge assistée par le vide ? IMAGERIE DE LA FEMME 2004. [DOI: 10.1016/s1776-9817(04)94823-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
18
|
Plantade R, Hammou JC, Fighiera M, Aubanel D, Scotto A, Gueret S. Sous-estimation du cancer du sein par les macrobiopsies stéréotaxiques 11-gauge assistées par le vide. ACTA ACUST UNITED AC 2004; 85:391-401. [PMID: 15213649 DOI: 10.1016/s0221-0363(04)97598-1] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
PURPOSE To assess the reliability of vacuum-assisted biopsy in diagnosing and managing atypical ductal hyperplasia and ductal carcinoma in situ of the breast. MATERIALS AND METHOD Retrospective review of 2130 stereotactic large-core biopsies in 1638 patients over a 40 month period (January 2000 to May 2003) using the mammotome 11-gauge and a dedicated Fischer table. A total of 135 cases of atypical ductal hyperplasia and 322 cases of ductal carcinoma in situ were diagnosed. The average number of cores was 18 (5-64). Surgical resection was systematic for carcinomas and selective for atypical ductal hyperplasia. Correlation with surgical findings (n:356) or mammographic follow-up (n:98) is presented. The influence of various factors on the risk of underestimation was analyzed. RESULTS Resection revealed an underestimation of 10/37 (27%) for atypical ductal hyperplasia. It was lower (9%) when the radiological lesion had completely disappeared. Underestimation of ductal carcinoma in situ was 12/319 (3.8%). It was higher for masses, high-grade lesions or with micro-infiltration, or in the case where the peripheral edge was affected. Of the 98 atypical ductal hyperplasia that were not surgically biopsied, 81 were monitored at 9-42 months (average: 29 months). Sixteen underwent repeat biopsy: two infiltrating lobular carcinomas were detected in the same area. CONCLUSION Underestimation of atypical ductal hyperplasia was high, justifying systematic surgical resection. Underestimation of ductal carcinoma in situ and its practical consequences are not significant with the extension of sentinel lymphadenectomy to the wide high-grade lesions or with micro-infiltration.
Collapse
Affiliation(s)
- R Plantade
- Centre d'imagerie médicale Nice Europe, 15 rue Alberti, 06000 Nice.
| | | | | | | | | | | |
Collapse
|
19
|
Microcalcificaciones con diagnóstico de benignidad en biopsia con aguja gruesa (14G): seguimiento y falsos negativos en 76 casos. RADIOLOGIA 2004. [DOI: 10.1016/s0033-8338(04)77981-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
20
|
Leifland K, Lundquist H, Lagerstedt U, Svane G. Comparison of preoperative simultaneous stereotactic fine needle aspiration biopsy and stereotactic core needle biopsy in ductal carcinoma in situ of the breast. Acta Radiol 2003. [PMID: 12694110 DOI: 10.1034/j.1600-0455.2003.00026.x] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
PURPOSE To compare the preoperative results of stereotactic fine needle aspiration biopsy (S-FNAB) with stereotactic core needle biopsy (S-CNB) performed simultaneously in breast lesions with the postoperative histopathological diagnosis of ductal carcinoma in situ (DCIS) of all histological grades. MATERIAL AND METHODS 733 consecutive stereotactic biopsies were performed between May 1993 and June 1999. In 72 patients with mammographic findings suspicious of malignancy who were subjected to breast surgery, postoperative histopathology showed DCIS. Preoperatively, S-FNAB and S-CNB had been done simultaneously in all patients, S-FNAB with spinal needle 0.7 or 0.9 mm and S-CNB was performed with an automated 2.1-mm biopsy gun. An average of 3 S-FNABs and 3 S-CNBs were performed in each patient. RESULTS In 56 (78%) of the 72 patients S-CNB showed DCIS. In 3 patients (4%) the S-CNB revealed "probable carcinoma", in 7 patients (10%) "atypia" and in 6, the lesions were benign. In 34 (47%) of the 72 women S-FNABs showed carcinoma, not otherwise specified. In 6 cases (8%) the S-FNABs showed "probable carcinoma" and in 12 patients (17%) "atypia"; 8 lesions were benign and 12 not diagnostic. CONCLUSION S-CNB was superior to S-FNAB in diagnosing DCIS. Only 6 patients (8%) received a benign or non-diagnostic preoperative diagnosis with S-CNB compared to 20 patients (28%) with S-FNAB. S-CNB was superior to S-FNAB for preoperative diagnosis of DCIS, but S-FNAB could further increase the sensitivity of the biopsy since it diagnosed cancer in 4 cases where S-CNB showed benign material.
Collapse
Affiliation(s)
- K Leifland
- Mammography Section, Department of Radiology, St. Göran Hospital Inc., Stockholm, Sweden.
| | | | | | | |
Collapse
|
21
|
Pandelidis S, Heiland D, Jones D, Stough K, Trapeni J, Suliman Y, Heilman D. Accuracy of 11-gauge vacuum-assisted core biopsy of mammographic breast lesions. Ann Surg Oncol 2003; 10:43-7. [PMID: 12513959 DOI: 10.1245/aso.2003.05.004] [Citation(s) in RCA: 69] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
BACKGROUND Image-guided percutaneous biopsy has largely replaced excisional biopsy of mammographic lesions. Vacuum-assisted core biopsy has improved sampling of such lesions. The objectives of this study were to define the accuracy of the vacuum-assisted 11-gauge stereotactic core biopsy in sampling of atypical ductal hyperplasia (ADH) and ductal carcinoma in situ (DCIS) and to define histologic and mammographic features of target lesions, which predict sampling errors. METHODS Between October 1996 and March 2000, 1341 patients underwent stereotactic 11-gauge vacuum-assisted biopsy. Patients with ADH or DCIS were encouraged to undergo excisional biopsy. RESULTS Surgical excision of 37 ADH lesions revealed 5 missed DCIS lesions and 1 missed invasive cancer. Twelve of 91 DCIS lesions were upstaged to invasive cancer upon excision. The underestimation rate was highest in patients with DCIS when the target lesion for biopsy was a zone of calcifications >1.5 cm. No correlation existed between the histologic features of DCIS lesions diagnosed by stereotactic biopsy and the presence of infiltrating disease on excision. CONCLUSIONS Vacuum-assisted 11-gauge stereotactic core biopsy understages 13.2% and 13.5% of DCIS and ADH lesions, respectively. In patients with DCIS found by stereotactic biopsy, a target zone of calcifications >1.5 cm is associated with a higher underestimation rate of infiltrating disease.
Collapse
|
22
|
Evans AJ, Blanks RG. Should breast screening programmes limit their detection of ductal carcinoma in situ? Clin Radiol 2002; 57:1086-9. [PMID: 12475533 DOI: 10.1053/crad.2002.1097] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE Previous research has shown that the detection of ductal carcinoma in situ (DCIS) aids the detection of small invasive cancers at mammographic screening. A correlation may therefore exist between a screening unit's DCIS detection rate and their small invasive cancer detection rate. We have therefore investigated the effect of DCIS detection rate on the detection of small (<15 mm) invasive cancers in the 95 units of the U.K. NHS Breast Screening Programme (NHSBSP). MATERIALS AND METHODS DCIS detection rates were examined against large (> or =15 mm) and small (<15 mm) invasive cancer detection rates in women aged 50-64 years at prevalent and incident screens over a 3-year period. RESULTS After adjusting for background incidence, screening units with the highest DCIS detection of > or =1.3/1000 detected over 20% more small invasive cancers than units with DCIS detection rates within the NHSBSP guidelines of 0.5-1/1000 (P<0.001). Sixty percent of units had DCIS detection rates above the guidelines. There was no correlation between DCIS detection and > or =15 mm invasive cancer detection. The results suggest that over the range of DCIS rates studied, that for every two extra DCIS cancers detected, an additional small invasive cancer (<15 mm) is detected that may otherwise not have been. The results therefore provide supporting evidence that the detection of DCIS aids the detection of small invasive cancers. CONCLUSION Units with DCIS detection above the NHSBSP guidelines have significantly better small invasive cancer detection rates. The existence of an upper limit for DCIS detection within the NHSBSP may be preventing the detection of small invasive cancers, because units are not recalling some small clusters of calcification in order to keep DCIS detection rates down. The upper limit may therefore be inappropriate.
Collapse
Affiliation(s)
- A J Evans
- Helen Garrod Breast Screening Unit, City Hospital, Hucknall Road, Nottingham, NG5 1PB, UK.
| | | |
Collapse
|
23
|
Abstract
Percutaneous image-guided core biopsy is an accurate, fast, minimally invasive, and less expensive alternative to surgery for the diagnosis of breast lesions. Percutaneous core biopsy is usually performed under stereotactic or ultrasound guidance, using an automated needle or vacuum-assisted biopsy probe. Use of percutaneous core biopsy spares the need for surgery in most women with benign disease and expedites treatment in women with breast cancer. This article reviews advantages, limitations, controversies, and future directions in percutaneous image-guided core breast biopsy.
Collapse
Affiliation(s)
- Laura Liberman
- Department of Radiology, Memorial Sloan-Kettering Cancer Center, New York, NY 10021, USA.
| |
Collapse
|
24
|
|
25
|
Becker L, Taves D, McCurdy L, Muscedere G, Karlik S, Ward S. Stereotactic core biopsy of breast microcalcifications: comparison of film versus digital mammography, both using an add-on unit. AJR Am J Roentgenol 2001; 177:1451-7. [PMID: 11717106 DOI: 10.2214/ajr.177.6.1771451] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE The goal of this study was to assess the accuracy of an add-on stereotactic unit for core biopsy of indeterminate breast microcalcifications and to compare digital with conventional stereotactic guidance. MATERIALS AND METHODS We conducted a retrospective review of 232 lesions with indeterminate microcalcifications in 218 women who underwent stereotactically guided breast biopsies. All biopsies were performed using a standard mammography machine with an add-on unit, 121 with conventional and 111 with digital stereotactic guidance. Successful sampling of the lesion was determined by the detection of microcalcifications on specimen radiography or at pathology. RESULTS Using the add-on unit, 219 (94.4%) of the 232 targeted lesions were successfully sampled. The size, location, number of cores per lesion, and histology of the lesions were not different between the conventional and digital stereotactic biopsy groups (p > 0.1). Indeterminate microcalcifications were missed on biopsy in nine (7.4%) of 121 cases using conventional radiography and in only four (3.6%) of 111 cases using digital imaging. Digital stereotactic guidance allowed sampling of lesions with fewer calcifications per square centimeter (p < 0.001). CONCLUSION Sampling of indeterminate microcalcifications using a standard mammography machine and an add-on unit has a high accuracy, similar to rates reported for dedicated prone biopsy tables. An add-on unit offers the advantage of considerable cost and space savings. Relative to conventional radiography, digital stereotactic guidance allows lesions with fewer calcifications to be sampled and achieves a greater biopsy success rate. Immediate digital images in the biopsy room also permit rapid adjustment of alignment and minimize patient movement.
Collapse
Affiliation(s)
- L Becker
- Radiology Department, St Joseph's Health Care, 268 Grosvenor St, London, Ontario N6A 4V2, Canada
| | | | | | | | | | | |
Collapse
|
26
|
Dahlstrom JE, Jain S. Histological correlation of mammographically detected microcalcifications in stereotactic core biopsies. Pathology 2001; 33:444-8. [PMID: 11827410 DOI: 10.1080/00313020120083160] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
The aims of this study were to assess the value of specimen radiographs of stereotactic core biopsy, the usefulness of measuring size of calcifications on tissue sections, whether demonstration of calcifications in tissue sections alters the pathological diagnosis when specimen radiograph demonstrates calcifications, and to correlate these assessments with diagnostic outcome. A total of 301 core biopsies from 266 women with 274 mammographically suspicious areas of calcifications were examined. Core biopsies (five cores per procedure) were obtained stereotactically using a 14-gauge needle in an automated Biopty gun. Prior to processing of the tissue, 214 core biopsy specimens from 193 women with 197 lesions were radiographed. Of the 301 core biopsies, 56 (19%) were diagnosed as malignant, 15 (5%) were diagnosed as atypical ductal hyperplasia and 230 (76%) contained benign breast tissue. Of the core biopsies diagnosed as benign, 160 (70%) had specimen radiography prior to processing. Of these, 109 (69%) core biopsies showed calcifications on specimen radiographs. In 96 (88%) of these core biopsies, calcifications measuring > 100 microm were found on the initial tissue sections. In 11 (10%) further deeper sections were required to detect calcifications > 100 microm; however, this did not result in a change of the pathological diagnosis. Two of the 109 (1.8%) "benign" core biopsies, which contained tissue calcifications > 100 microm and at that time were considered representative of the mammographic lesion, have had a malignant outcome on clinical and mammographic follow-up ranging from 2.4 to 7.5 years. Of the 51 (31%) core biopsies where calcifications were not seen on specimen radiographs, histological calcifications were not found in 34 (67%) core biopsies, whereas in 17 (33%) core biopsies, calcifications measuring < 100 microm were found. All of these core biopsies were considered non-diagnostic and therefore not representative of the lesion targeted. Five (9.8%) of these cases had a malignant outcome with either immediate rebiopsy or excision. Accurate diagnosis of all mammographic lesions requires radiological-pathological correlation. This study shows that the presence of calcifications on the specimen radiograph and the demonstration of tissue calcifications > 100 microm are an essential and highly reliable part of core biopsy assessment for mammographically "suspicious" calcifications. Nevertheless, lesions with "highly suspicious" calcifications on mammography should be considered for excision even if the core biopsy diagnosis is benign and calcifications > 100 microm are present.
Collapse
Affiliation(s)
- J E Dahlstrom
- Department of Anatomical Pathology, University of Sydney, Canberra Hospital, Australia.
| | | |
Collapse
|
27
|
Berg WA, Arnoldus CL, Teferra E, Bhargavan M. Biopsy of amorphous breast calcifications: pathologic outcome and yield at stereotactic biopsy. Radiology 2001; 221:495-503. [PMID: 11687695 DOI: 10.1148/radiol.2212010164] [Citation(s) in RCA: 85] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To assess the pathologic outcome of amorphous breast calcifications and the success of stereotactic biopsy for such lesions. MATERIALS AND METHODS From July 1995 through February 2000, biopsy of all clustered amorphous calcifications not clearly stable for at least 5 years or in a diffuse scattered distribution was recommended. Logistic regression analysis was used to stratify the risk of malignancy by patient risk factors, calcification distribution, and stability. RESULTS Calcifications were retrieved from 150 biopsies; 30 (20%) proved malignant and included 27 ductal carcinomas in situ and three low-grade invasive and intraductal carcinomas (2-5 mm). Another 30 (20%) yielded high-risk lesions, including 21 atypical ductal hyperplasia, eight atypical lobular hyperplasia, and one lobular carcinoma in situ. In 150 lesions, stereotactic biopsy was performed on 113 and aborted in 10. Calcifications were retrieved from all 113 stereotactic biopsies. Of those with calcification retrieval, there were three histologic underestimates (accuracy, 97%). Stereotactic biopsy spared a surgical procedure in 57 (46%) of 123 patients. Needle localization was required for 23 (15%) of 150 patients due to poor conspicuity. Five (45%) of 11 biopsies performed in women with ipsilateral breast cancer showed malignancy (P = .025). When multiple lesions of amorphous calcifications were present in one breast, sampling of one reliably predicted the outcome of others. CONCLUSION We found a substantial rate of ductal carcinoma in situ and high-risk lesions associated with amorphous calcifications. Stereotactic biopsy can be successfully performed for the majority of subtle amorphous calcifications; however, only a minority were spared a surgical procedure.
Collapse
Affiliation(s)
- W A Berg
- Department of Radiology, Greenebaum Cancer Center, University of Maryland, 419 W Redwood St, Suite 110, Baltimore, MD 21201, USA.
| | | | | | | |
Collapse
|
28
|
Liberman L, Gougoutas CA, Zakowski MF, LaTrenta LR, Abramson AF, Morris EA, Dershaw DD. Calcifications highly suggestive of malignancy: comparison of breast biopsy methods. AJR Am J Roentgenol 2001; 177:165-72. [PMID: 11418420 DOI: 10.2214/ajr.177.1.1770165] [Citation(s) in RCA: 58] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE The purpose of this study was to compare the usefulness of, and cost of diagnosing with, different breast biopsy methods for women with calcifications highly suggestive of malignancy. MATERIALS AND METHODS One hundred thirty-nine women with calcifications highly suggestive of malignancy underwent diagnostic biopsy. Of these, 89 women had stereotactic biopsy with a 14-gauge automated needle (n = 25), 14-gauge vacuum-assisted probe (n = 17), or 11-gauge vacuum-assisted probe (n = 47); and 50 women had diagnostic surgical biopsy. Medical records were reviewed. Cost savings for stereotactic biopsy were calculated using Medicare data. RESULTS The median number of operations was one for women who had stereotactic biopsy versus two for women who had diagnostic surgical biopsy. The likelihood of undergoing a single operation was significantly greater for women who had stereotactic rather than surgical biopsy, among all women (61/89 [68.5%] vs. 19/50 [38.0%], p < 0.001) and among women treated for breast cancer (55/77 [71.4%] vs. 6/37 [16.2%], p = 0.0000001). Stereotactic 11-gauge vacuum-assisted biopsy, as compared with 14-gauge automated core or 14-gauge vacuum-assisted biopsy, was significantly more likely to spare a surgical procedure (36/47 [76.6%] vs. 16/42 [38.1%], p = 0.0005). Stereotactic 11-gauge vacuum-assisted biopsy resulted in the greatest cost reduction, yielding savings of $315 per case compared with diagnostic surgical biopsy; for women with solitary lesions, stereotactic 11-gauge biopsy decreased the cost of diagnosis by 22.2% ($334/$1502). CONCLUSION For women with calcifications highly suggestive of malignancy, the use of stereotactic rather than surgical biopsy decreases the number of operations. Stereotactic 11-gauge vacuum-assisted biopsy, as compared with 14-gauge automated core or 14-gauge vacuum-assisted biopsy, is significantly more likely to spare a surgical procedure and has the highest cost savings.
Collapse
Affiliation(s)
- L Liberman
- Breast Imaging Section, Department of Radiology, Memorial Sloan-Kettering Cancer Center, 1275 York Ave., New York, NY 10021, USA
| | | | | | | | | | | | | |
Collapse
|
29
|
Singletary SE. Minimally invasive techniques in breast cancer treatment. SEMINARS IN SURGICAL ONCOLOGY 2001; 20:246-50. [PMID: 11523110 DOI: 10.1002/ssu.1040] [Citation(s) in RCA: 48] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Breast conservation therapy has largely replaced mastectomy as the surgical treatment of choice for early-stage breast cancer. As the sentinel lymph node mapping procedure, rather than routine axillary node dissection, becomes the standard of care, the next challenge is how to treat the primary tumor without surgery. Minimally invasive ablation of the primary tumor is possible with a variety of approaches; the goal is to either excise the tumor percutaneously or cool it (with cryotherapy) or heat it (with radiofrequency ablation (RFA), focused ultrasound, or laser interstitial therapy) sufficiently to cause complete cell death. These developing technologies may provide treatment options that are psychologically and cosmetically more acceptable to the patient than traditional therapies, but they need further investigation to prove that they are oncologically sound. This new frontier of surgery without scalpels will require surgeons to develop radiologic expertise and to acquire a basic understanding of molecular biology.
Collapse
Affiliation(s)
- S E Singletary
- Department of Surgical Oncology, University of Texas M. D. Anderson Cancer Center, 1515 Holcombe Boulevard, Houston, TX 77030, USA.
| |
Collapse
|
30
|
Cangiarella J, Waisman J, Symmans WF, Gross J, Cohen JM, Wu H, Axelrod D. Mammotome core biopsy for mammary microcalcification: analysis of 160 biopsies from 142 women with surgical and radiologic followup. Cancer 2001; 91:173-7. [PMID: 11148574 DOI: 10.1002/1097-0142(20010101)91:1<173::aid-cncr22>3.0.co;2-9] [Citation(s) in RCA: 83] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
BACKGROUND Although stereotaxic fine-needle aspiration biopsy or core biopsy (14-gauge) have proven to be accurate techniques for the evaluation of mammographically detected microcalcification, the development of the Mammotome Biopsy System (Biopsys Medical, Inc., Irvine, CA) has led many medical centers to use this vacuum-assisted device for the sampling of microcalcification. METHODS One hundred forty-two women underwent 160 stereotaxic Mammotome core biopsies of mammographic calcification over a 1-year period. The stereotaxic procedure was performed by radiologists using the Mammotome Biopsy System. Microcalcification was evident on specimen radiographs and microscopic slides in 99% of the cases. Excisional biopsy was recommended for diagnoses of atypia or carcinoma. Patients with benign diagnoses underwent mammographic followup. RESULTS One hundred thirty-two benign, 12 atypical, and 15 adenocarcinoma diagnoses (comprising 1 lobular adenocarcinoma in situ [LCIS], 1 invasive ductal adenocarcinoma [IDC], and 13 intraductal adenocarcinomas [DCIS]: 10 comedo, 1 cribriform, 2 mixed cribriform and micropapillary) were rendered. Surgical excision in eight patients with atypia on Mammotome biopsy (two refused surgery, two were lost to followup) showed ductal hyperplasia in three, atypical ductal hyperplasia (ADH) in three and DCIS (low grade, solid) in two patients. Surgical excisions in 14 patients diagnosed with carcinoma (1 patient lost to followup) showed ADH in 3, ADH and LCIS in 1, residual DCIS in 8, IDC in 1, and microinvasive carcinoma in 1 patient. CONCLUSIONS A diagnosis of atypia on Mammotome biopsy warranted excision of the atypical area, yet the underestimation rate for the presence of carcinoma remained low. The likelihood of an invasive component at excision was low for microcalcification diagnosed as DCIS on Mammotome biopsy. Mammotome biopsy proved to be an accurate technique for the sampling and diagnosis of mammary microcalcification.
Collapse
Affiliation(s)
- J Cangiarella
- Department of Pathology, New York University Medical Center, New York, New York 10016, USA.
| | | | | | | | | | | | | |
Collapse
|
31
|
Cintora E, Landeras R, Vela AC, Cura JLD, Operé E, Grande D. Rentabilidad de la biopsia con aguja gruesa guiada mediante estereotaxia en el estudio de calcificaciones mamarias. RADIOLOGIA 2001. [DOI: 10.1016/s0033-8338(01)76949-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
32
|
Darling ML, Smith DN, Lester SC, Kaelin C, Selland DL, Denison CM, DiPiro PJ, Rose DI, Rhei E, Meyer JE. Atypical ductal hyperplasia and ductal carcinoma in situ as revealed by large-core needle breast biopsy: results of surgical excision. AJR Am J Roentgenol 2000; 175:1341-6. [PMID: 11044038 DOI: 10.2214/ajr.175.5.1751341] [Citation(s) in RCA: 241] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE This investigation compares the frequency of histologic underestimation of breast carcinoma that occurs when a large-core needle biopsy reveals atypical ductal hyperplasia or ductal carcinoma in situ with the automated 14-gauge needle, the 14-gauge directional vacuum-assisted biopsy device, and the 11-gauge directional vacuum-assisted biopsy device. SUBJECTS AND METHODS Evaluation of 428 large-core needle biopsies yielding atypical ductal hyperplasia (139 lesions) or ductal carcinoma in situ (289 lesions) was performed. The results of subsequent surgical excision were retrospectively compared with the needle biopsy results. RESULTS For lesions initially diagnosed as ductal carcinoma in situ, underestimation of invasive ductal carcinoma was significantly less frequent using the 11-gauge directional vacuum-assisted biopsy device when compared with the automated 14-gauge needle (10% versus 21%, p < 0.05) but was not significantly less frequent when compared with the 14-gauge directional vacuum-assisted device (10% versus 17%, p > 0.1). For lesions diagnosed initially as atypical ductal hyperplasia, underestimation of ductal carcinoma in situ and invasive ductal carcinoma was significantly less frequent using the 11-gauge directional vacuum-assisted biopsy device compared with the 14-gauge directional vacuum-assisted device (19% versus 39%, p = 0. 025) and with the automated 14-gauge needle (19% versus 44%, p = 0. 01). CONCLUSION The frequency of histologic underestimation of breast carcinoma in lesions initially diagnosed as atypical ductal hyperplasia or ductal carcinoma in situ using large-core needle biopsy is substantially lower with the 11-gauge directional vacuum-assisted device than with the automated 14-gauge needle and with the 14-gauge directional vacuum-assisted device.
Collapse
Affiliation(s)
- M L Darling
- Department of Radiology, Brigham and Women's Hospital, 75 Francis St., Boston, MA 02115, USA
| | | | | | | | | | | | | | | | | | | |
Collapse
|
33
|
Moritz JD, Mertens C, Westerhof JP, Oestmann JW. Role of high magnification specimen radiography in surgical and core biopsies of the breast. Br J Radiol 2000; 73:1170-7. [PMID: 11144794 DOI: 10.1259/bjr.73.875.11144794] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
The clinical relevance of a high magnification specimen radiography (HMSR) system in breast biopsies was evaluated and compared with conventional specimen radiography with a mammography system (SRM). 100 surgical biopsies of 72 patients and 248 core biopsies of 30 patients were examined in (a) maximal 20-fold HMSR in combination with storage phosphors and (b) 1.8-fold SRM using a film-screen system. Detection of calcifications/soft tissue lesions and the impact on management were evaluated. In surgical biopsies, SRM could detect only 22% of individual microcalcifications, 39% of calcified lesions and 67% of soft tissue lesions identified with HMSR. Calcifications down to 10 microns were identified with HMSR. In five biopsies, peripheral calcifications leading to additional resection were recognized only with HMSR; in three of these they were indicative of malignant tissue. In core biopsies, only 12% of individual microcalcifications seen with HMSR were identified with SRM. 52% and 16% of all cores were calcified on HMSR and SRM, respectively. Microcalcifications within cores were found only with HMSR in 41% of patients with calcified lesions. In conclusion, the better detectability of microcalcifications with HMSR led to justified additional tissue resections in surgical patients and reduced the number of core biopsies required in interventional patients.
Collapse
Affiliation(s)
- J D Moritz
- Department of Diagnostic Radiology, Klinikum der Georg-August-Universität, Robert Koch Strasse 40, 37075 Göttingen, Germany
| | | | | | | |
Collapse
|
34
|
Russin LD. New directions in breast biopsy: review of current minimally invasive methods and presentation of a new coaxial technique. Semin Ultrasound CT MR 2000; 21:395-403. [PMID: 11071619 DOI: 10.1016/s0887-2171(00)90032-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Minimally invasive core breast biopsy methods are replacing hook-wire-guided surgery wherever ultrasound and stereotactic equipment are available. Cost efficiency is improved, but sampling errors inherent in these techniques cause underestimations of malignancy and the degree of invasiveness in a small but significant number of patients. Diagnostic accuracy improves with increasing specimen weight. The trend is to take many cores. How much tissue is enough to enable a confident diagnosis? Recent research suggests that 1 g of tissue is sufficient. A new coaxial biopsy method presented here can retrieve a contiguous 1-g block of tissue from the center of a mammographic lesion, without stereotactic guidance. This specimen may be superior to multiple small cores obtained by biopsy guns and vacuum devices.
Collapse
Affiliation(s)
- L D Russin
- Department of Radiology, Noble Hospital, Westfield, MA 01086, USA.
| |
Collapse
|
35
|
Bagnall MJ, Evans AJ, Wilson AR, Burrell H, Pinder SE, Ellis IO. When have mammographic calcifications been adequately sampled at needle core biopsy? Clin Radiol 2000; 55:548-53. [PMID: 10924380 DOI: 10.1053/crad.1999.0483] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
AIMS To determine if the number of flecks of calcification retrieved at stereotaxic core needle biopsy or the number of core samples obtained containing calcification are related to biopsy sensitivity, and to determine how many calcifications or cores containing calcification the radiologist should aim to retrieve when sampling mammographic microcalcification. MATERIALS AND METHODS A retrospective review was performed of core specimen radiographs from 57 consecutive patients who had stereotaxic core needle biopsies of impalpable malignant microcalcifications without an associated mammographic mass. The total number of calcifications retrieved and the numbers of cores containing calcification were correlated with findings at core and surgical histology. RESULTS Increasing retrieval of calcification elements visible on specimen radiography was associated with increasing sensitivity of the biopsy. Five or more flecks of calcium gave an absolute sensitivity of 100%. Increasing numbers of core samples obtained containing radiographically demonstrable calcification was also associated with increasing sensitivity. Three or more cores containing calcium resulted in a 100% absolute sensitivity for malignancy. CONCLUSION To ensure adequate sampling of calcification at core biopsy, an optimum of either three or more cores containing calcium or five or more flecks of calcium in total is required. Achieving this target ensures a high pre-operative diagnosis rate for malignant microcalcifications.Bagnall, M. J. C. (2000). Clinical Radiology 55, 548-553.
Collapse
Affiliation(s)
- M J Bagnall
- Breast Screening Training Centre, Nottingham City Hospital, Nottingham, U.K
| | | | | | | | | | | |
Collapse
|
36
|
Abstract
Percutaneous imaging-guided core biopsy is a less invasive and less expensive alternative to surgical biopsy for the evaluation of breast lesions. Percutaneous core biopsy is most often used for evaluation of BI-RADS category 4 lesions, but may also be helpful in the evaluation of some BI-RADS category 5 lesions. Stereotactic guidance is particularly useful for calcifications; for masses that can be seen with ultrasound, ultrasound guidance may be preferable because of the absence of radiation and lower cost. The automated core biopsy needle is excellent for mass lesions, but directional vacuum-assisted biopsy is superior for calcifications. Directional vacuum-assisted biopsy may also be preferable for small lesions that may require placement of a localizing clip and lesions that are superficial or in thin breasts. The more expensive ABBI device has substantial limitations, and its role in percutaneous breast biopsy has not been demonstrated. Complete removal of the mammographic target can occur at percutaneous biopsy, and is a more frequent event when the larger tissue acquisition devices are used. Complete removal of the mammographic target does not ensure complete excision of the histologic process. Further investigation is necessary to determine in which lesions, if any, complete removal of the target is advantageous. Epithelial displacement can occur during all breast needling procedures, but may be less frequent at directional vacuum-assisted biopsy than at fine-needle aspiration or automated core biopsy. There is no evidence that displaced cells are of biologic significance, but displaced DCIS can mimic infiltrating carcinoma. The pathologist should be aware of the findings of epithelial displacement, to avoid misdiagnosing DCIS as infiltrating ductal carcinoma. Some lesions warrant repeat biopsy or surgical excision after percutaneous core biopsy. Repeat biopsy is warranted if histologic findings and imaging findings are discordant. Surgical excision is warranted for lesions yielding a percutaneous diagnosis of ADH or possible phyllodes tumor. Controversy exists regarding the need for surgical excision after percutaneous diagnosis of radial scar, papillary lesion, ALH, or LCIS. Follow-up is necessary if percutaneous biopsy yields benign findings concordant with imaging characteristics. Follow-up protocols vary, but all require substantial commitment of time and resources. We have an embarassment of riches for performing percutaneous core biopsy of the breast. It can be estimated that approximately 1 million breast biopsies will be performed this year to diagnose approximately 200,000 breast cancers. Percutaneous core biopsy may spare many of these women the need for a more deforming, invasive, and expensive surgical biopsy. Further work is necessary to optimize criteria for patient selection, develop and define the role of new technologies for tissue acquisition, refine protocols for management after percutaneous breast biopsy, and assess long-term outcome, so that more women can benefit from this minimally invasive approach to breast diagnosis.
Collapse
Affiliation(s)
- L Liberman
- Department of Radiology, Memorial Sloan-Kettering Cancer Center, New York, New York, USA.
| |
Collapse
|
37
|
Liberman L, Sama MP. Cost-effectiveness of stereotactic 11-gauge directional vacuum-assisted breast biopsy. AJR Am J Roentgenol 2000; 175:53-8. [PMID: 10882245 DOI: 10.2214/ajr.175.1.1750053] [Citation(s) in RCA: 84] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE The purpose of our study was to determine the frequency with which stereotactic 11-gauge directional vacuum-assisted breast biopsy obviated a surgical procedure and to calculate cost savings attributable to that biopsy method. MATERIALS AND METHODS We retrospectively reviewed 200 consecutive solitary nonpalpable lesions on which stereotactic 11-gauge directional vacuum-assisted breast biopsy was performed. Cost savings were calculated using Medicare reimbursements. Mammograms, histologic findings, and medical records were reviewed. RESULTS Stereotactic 11-gauge directional vacuum-assisted biopsy obviated a surgical procedure in 151 (76%) of 200 lesions, including 112 (73%) of 154 calcific lesions and 39 (85%) of 46 masses. Reasons for not obviating a surgical procedure in 49 lesions (25%) included recommendation for surgical biopsy in 35 lesions (18%), small carcinomas treated by excision in 10 lesions (5%), and histologic underestimation in four lesions (2%). Stereotactic 11-gauge directional vacuum-assisted biopsy decreased the cost of diagnosis by S264 per case, a 20% ($264/$1289) decrease in the cost of diagnosis compared with surgical biopsy. Of 200 lesions that had stereotactic 11-gauge directional vacuum-assisted biopsy, 106 (53%) would not have been amenable to 14-gauge automated core biopsy because of their small size, their superficial location, or inadequate breast thickness. CONCLUSION Stereotactic 11-gauge directional vacuum-assisted breast biopsy obviated a surgical procedure in 76% of lesions, yielding a 20% decrease in cost of diagnosis compared with surgical biopsy. Although savings per case are modest, 11-gauge directional vacuum-assisted biopsy expands the spectrum of lesions amenable to stereotactic biopsy, increasing cost savings in the population.
Collapse
Affiliation(s)
- L Liberman
- Department of Radiology, Memorial Sloan-Kettering Cancer Center, New York, NY 10021, USA
| | | |
Collapse
|
38
|
Affiliation(s)
- B Wright
- Department of Medical Imaging, Sunnybrook and Women's College Health Sciences Centre, University of Toronto, Ontario, Canada
| | | |
Collapse
|
39
|
Reynolds HE. Core needle biopsy of challenging benign breast conditions: a comprehensive literature review. AJR Am J Roentgenol 2000; 174:1245-50. [PMID: 10789770 DOI: 10.2214/ajr.174.5.1741245] [Citation(s) in RCA: 77] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Affiliation(s)
- H E Reynolds
- Department of Radiology, Indiana University School of Medicine, Indiana University Hospital, Indianapolis 46202, USA
| |
Collapse
|
40
|
Whitlock JP, Evans AJ, Burrell HC, Pinder SE, Ellis IO, Blamey RW, Wilson AR. Digital imaging improves upright stereotactic core biopsy of mammographic microcalcifications. Clin Radiol 2000; 55:374-7. [PMID: 10816404 DOI: 10.1053/crad.2000.0447] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
AIM This comparative study was carried out to assess the effect of using digital images compared to conventional film-screen mammography on the accuracy of core biopsy of microcalcifications using upright stereotactic equipment. MATERIALS AND METHODS The biopsy results from a consecutive series of 104 upright stereotactic 14-gauge core biopsies performed with conventional X-ray (Group A) were compared with 40 biopsies carried out using stereotaxis with digital imaging (Group B). In all cases specimen radiography was performed and analysed for the presence of calcifications. Pathological correlation was then carried out with needle and surgical histology. RESULTS The use of digital add-on equipment increased the radiographic calcification retrieval rate from 55 to 85% (P < 0.005). The absolute sensitivity of core biopsy in pure ductal carcinoma in situ (DCIS) cases rose from 34 to 69% (P < 0.03), with the complete sensitivity increasing from 52 to 94% (P < 0.005). For DCIS with or without an invasive component the absolute sensitivity rose from 41 to 67% (P = 0.052), while the complete sensitivity was 59% before and 86% after the introduction of digital imaging (P < 0.04). CONCLUSION Digital equipment improves the performance of upright stereotactic core biopsy of microcalcifications, giving a significantly increased success rate in accurately obtaining calcifications. This leads to an improvement in absolute and complete sensitivity of core biopsy when diagnosing DCIS.
Collapse
Affiliation(s)
- J P Whitlock
- National Breast Screening Training Centre, Nottingham City Hospital, Nottingham, NG5 1PB, U.K
| | | | | | | | | | | | | |
Collapse
|
41
|
Liberman L. Centennial dissertation. Percutaneous imaging-guided core breast biopsy: state of the art at the millennium. AJR Am J Roentgenol 2000; 174:1191-9. [PMID: 10789761 DOI: 10.2214/ajr.174.5.1741191] [Citation(s) in RCA: 169] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Affiliation(s)
- L Liberman
- Department of Radiology, Breast Imaging Section, Memorial Sloan-Kettering Cancer Center, New York, NY 10021, USA
| |
Collapse
|
42
|
Abstract
The current state of the art for breast imaging is reviewed in comparison with the methods of practice commonly in use 25-35 years ago to demonstrate the most important advances that have taken place in imaging techniques, operational considerations, interpretive approaches, and interventional procedures. Since 1965, breast imaging has progressed from the simple assessment of breast disease in a selected small number of symptomatic women to the comprehensive evaluation of both breast health and disease in a substantial percentage of all women aged 40 years and older. In the process, breast imaging has become an established radiologic subspecialty that accounts for at least 10% of all examinations performed by radiologists. Indeed, mammography now is the most common imaging examination that directly results in the reduction of mortality from disease.
Collapse
Affiliation(s)
- E A Sickles
- Department of Radiology, University of California Medical Center, San Francisco, CA 94115, USA
| |
Collapse
|
43
|
Evans AJ, Wilson AR, Burrell HC, Ellis IO, Pinder SE. Mammographic features of ductal carcinoma in situ (DCIS) present on previous mammography. Clin Radiol 1999; 54:644-6. [PMID: 10541387 DOI: 10.1016/s0009-9260(99)91083-8] [Citation(s) in RCA: 39] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
AIM To review previous mammograms of women found later to have DCIS and identify features which may have been missed or misinterpreted as benign. METHODS The previous mammograms of 50 women who developed DCIS were analysed. The mammographic features at diagnosis and on the prior mammograms were compared. RESULTS 11 (22%) of the previous mammograms were in retrospect abnormal; 5 (45%) of these had previously been assessed for the abnormality. All showed microcalcification. The following features were commoner at diagnosis than on previous films; rod shaped calcification (64 vs. 27%, P = 0.03) and a ductal distribution of calcification (76 vs. 45%, P = 0.05). Predominantly punctate calcification (64 vs. 12%, P = 0.001) and less than 10 calcifications in the cluster (54 vs. 24%, P = 0.05) were more common on the previous films. No difference was found in the frequency of granular calcification, branching calcification, irregularity in density, size or shape of calcification between the two groups. CONCLUSION Features of DCIS missed on previous mammography include small cluster size, less than 10 calcifications in the cluster, the absence of rod shaped calcifications, the absence of a ductal distribution and the presence of predominantly punctate calcification. Features frequently seen both at diagnosis and on previous films which might have allowed earlier diagnosis were granular calcifications which vary in size, density and shape in an irregularly shaped cluster. Focal clustered calcification deserves aggressive investigation.
Collapse
Affiliation(s)
- A J Evans
- The Breast Team, Nottingham City Hospital, Nottingham, UK
| | | | | | | | | |
Collapse
|
44
|
Abstract
The approach to women with breast complaints must be individualized based on the presenting problem, patients' age, and the degree of clinical suspicion. Needle-biopsy, techniques are often cost-effective. In patients with suspicious breast abnormalities, a thorough imaging workup facilitates the selection of definitive local therapy.
Collapse
Affiliation(s)
- S Scott
- Department of Surgery, Northwestern University Medical School, Chicago, Illinois, USA
| | | |
Collapse
|
45
|
|
46
|
Symmans WF, Weg N, Gross J, Cangiarella JF, Tata M, Mazzo JA, Waisman J. A prospective comparison of stereotaxic fine-needle aspiration versus stereotaxic core needle biopsy for the diagnosis of mammographic abnormalities. Cancer 1999. [DOI: 10.1002/(sici)1097-0142(19990301)85:5<1119::aid-cncr16>3.0.co;2-g] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|