1
|
Yoon D, Doyle Z, Lee P, Hargreaves B, Stevens K. Clinical evaluation of isotropic MAVRIC-SL for symptomatic hip arthroplasties at 3 T MRI. Magn Reson Imaging 2024; 111:256-264. [PMID: 38621551 PMCID: PMC11186338 DOI: 10.1016/j.mri.2024.04.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2024] [Revised: 04/07/2024] [Accepted: 04/12/2024] [Indexed: 04/17/2024]
Abstract
BACKGROUND 3D multi-spectral imaging (MSI) of metal implants necessitates relatively long scan times. OBJECTIVE We implemented a fast isotropic 3D MSI technique at 3 T and compared its image quality and clinical utility to non-isotropic MSI in the evaluation of hip implants. METHODS Two musculoskeletal radiologists scored images from coronal proton density-weighted conventional MAVRIC-SL and an isotropic MAVRIC-SL sequence accelerated with robust-component-analysis on a 3-point scale (3: diagnostic, 2: moderately diagnostic, 1: non-diagnostic) for overall image quality, metal artifact, and visualization around femoral and acetabular components. Grades were compared using a signed Wilcoxon test. Images were evaluated for effusion, synovitis, osteolysis, loosening, pseudotumor, fracture, and gluteal tendon abnormalities. Reformatted axial and sagittal images for both sequences were subsequently generated and compared for image quality with the Wilcoxon test. Whether these reformats increased diagnostic confidence or revealed additional pathology, including findings unrelated to arthroplasty that may contribute to hip pain, was also compared using the McNemar test. Inter-rater agreement was measured by Cohen's kappa. RESULTS 39 symptomatic patients with a total of 59 hip prostheses were imaged (mean age, 70 years ±9, 14 males, 25 females). Comparison scores between coronal images showed no significant difference in image quality, metal artifact, or visualization of the femur and acetabulum. Except for loosening, reviewers identified more positive cases of pathology on the original coronally-acquired isotropic sequence. In comparison of reformatted axial and sagittal images, the isotropic sequence scored significantly (p < 0.01) higher for overall image quality (3.0 vs 2.0) and produced significantly (p < 0.01) more cases of increased diagnostic confidence (42.4% vs 7.6%) or additional diagnoses (50.8% vs 22.9%). Inter-rater agreement was substantial (k = 0.798) for image quality. Mean scan times were 4.2 mins (isotropic) and 7.1 mins (non-isotropic). CONCLUSION Compared to the non-isotropic sequence, isotropic 3D MSI was acquired in less time while maintaining diagnostically acceptable image quality. It identified more pathology, including postoperative complications and potential pain-generating pathology unrelated to arthroplasty. This fast isotropic 3D MSI sequence demonstrates promise for improving diagnostic evaluation of symptomatic hip prostheses at 3 T while simultaneously reducing scan time.
Collapse
Affiliation(s)
- Daehyun Yoon
- Department of Radiology, Stanford University, Lucas MRS Center, 1201 Welch Road, Stanford, CA 94305, USA.
| | - Zoe Doyle
- Department of Radiology, Stanford University, Lucas MRS Center, 1201 Welch Road, Stanford, CA 94305, USA; Department of Radiology, VA Palo Alto Health Care System, 3801 Miranda Ave, Palo Alto, CA 94304, USA.
| | - Philip Lee
- Department of Electrical Engineering, Stanford University, 350 Jane Stanford Way, Stanford, CA 94305, USA.
| | - Brian Hargreaves
- Department of Radiology, Stanford University, Lucas MRS Center, 1201 Welch Road, Stanford, CA 94305, USA; Department of Electrical Engineering, Stanford University, 350 Jane Stanford Way, Stanford, CA 94305, USA; Department of Bioengineering, Stanford University, 443 Via Ortega, Rm 119, Stanford, CA 94305, USA.
| | - Kathryn Stevens
- Department of Radiology, Stanford University, Lucas MRS Center, 1201 Welch Road, Stanford, CA 94305, USA; Department of Orthopaedic Surgery, Stanford University, 430 Broadway Street, MC: 6342, Pavilion C, 4th Floor, Redwood City, CA 94063, USA.
| |
Collapse
|
2
|
Albano D, Pansa S, Messina C, Gitto S, Serpi F, Fusco S, Midiri F, Zagra L, Sconfienza LM. MRI of total hip arthroplasty: technical aspects and imaging findings. Insights Imaging 2024; 15:152. [PMID: 38900339 PMCID: PMC11189891 DOI: 10.1186/s13244-024-01717-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2024] [Accepted: 05/08/2024] [Indexed: 06/21/2024] Open
Abstract
Total hip arthroplasty (THA) is the best surgical approach for treating advanced hip degeneration, providing pain relief, and improved function in most cases. In the past, MR imaging quality has been highly compromised by in-plane distortions, inadequate fat saturation, and other artifacts due to metal components of THA. Technological advancements have made pathologic conditions, which were previously hidden by periprosthetic artifacts, outstanding features due to the optimization of several sequences. To date, several short and long-term complications involving bony and soft-tissue structures may be detected through magnetic resonance imaging (MRI). The use of MRI with adapted sequences and protocols may drastically reduce artifacts thereby providing essential pre-operative elements for planning revision surgery of failed THA. This review has the purpose of conveying new insights to musculoskeletal radiologists about the techniques to suppress metal-related artifacts and the hallmark MRI findings of painful THA. CRITICAL RELEVANCE STATEMENT: Advancements in metal-suppression have given radiologists the opportunity to play an emerging role in THA management. This article provides technical and imaging insights into challenges that can be encountered in cases of THA, which may present complications and characteristic imaging findings. KEY POINTS: Imaging total hip arthroplasty requires adapted MRI protocol and awareness of the common complications. We have reported the available metal-suppression sequences for evaluating total hip arthroplasty. Many structures and conditions should be considered when dealing with painful aseptic or septic arthroplasty.
Collapse
Affiliation(s)
- Domenico Albano
- IRCCS Istituto Ortopedico Galeazzi, Milano, Italy.
- Dipartimento di Scienze Biomediche, Chirurgiche ed Odontoiatriche, Università degli Studi di Milano, Milano, Italy.
| | - Simone Pansa
- Scuola di Specializzazione in Radiodiagnostica, Università degli Studi di Milano, Milano, Italy
| | - Carmelo Messina
- IRCCS Istituto Ortopedico Galeazzi, Milano, Italy
- Dipartimento di Scienze Biomediche per la Salute, Università Degli Studi di Milano, Milano, Italy
| | - Salvatore Gitto
- IRCCS Istituto Ortopedico Galeazzi, Milano, Italy
- Dipartimento di Scienze Biomediche per la Salute, Università Degli Studi di Milano, Milano, Italy
| | - Francesca Serpi
- IRCCS Istituto Ortopedico Galeazzi, Milano, Italy
- Dipartimento di Scienze Biomediche per la Salute, Università Degli Studi di Milano, Milano, Italy
| | - Stefano Fusco
- IRCCS Istituto Ortopedico Galeazzi, Milano, Italy
- Dipartimento di Scienze Biomediche per la Salute, Università Degli Studi di Milano, Milano, Italy
| | | | - Luigi Zagra
- IRCCS Istituto Ortopedico Galeazzi, Milano, Italy
| | - Luca Maria Sconfienza
- IRCCS Istituto Ortopedico Galeazzi, Milano, Italy
- Dipartimento di Scienze Biomediche per la Salute, Università Degli Studi di Milano, Milano, Italy
| |
Collapse
|
3
|
Chang EY, Bencardino JT, French CN, Fritz J, Hanrahan CJ, Jibri Z, Kassarjian A, Motamedi K, Ringler MD, Strickland CD, Tiegs-Heiden CA, Walker REA. SSR white paper: guidelines for utilization and performance of direct MR arthrography. Skeletal Radiol 2024; 53:209-244. [PMID: 37566148 PMCID: PMC10730654 DOI: 10.1007/s00256-023-04420-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/26/2023] [Revised: 07/23/2023] [Accepted: 07/29/2023] [Indexed: 08/12/2023]
Abstract
OBJECTIVE Direct magnetic resonance arthrography (dMRA) is often considered the most accurate imaging modality for the evaluation of intra-articular structures, but utilization and performance vary widely without consensus. The purpose of this white paper is to develop consensus recommendations on behalf of the Society of Skeletal Radiology (SSR) based on published literature and expert opinion. MATERIALS AND METHODS The Standards and Guidelines Committee of the SSR identified guidelines for utilization and performance of dMRA as an important topic for study and invited all SSR members with expertise and interest to volunteer for the white paper panel. This panel was tasked with determining an outline, reviewing the relevant literature, preparing a written document summarizing the issues and controversies, and providing recommendations. RESULTS Twelve SSR members with expertise in dMRA formed the ad hoc white paper authorship committee. The published literature on dMRA was reviewed and summarized, focusing on clinical indications, technical considerations, safety, imaging protocols, complications, controversies, and gaps in knowledge. Recommendations for the utilization and performance of dMRA in the shoulder, elbow, wrist, hip, knee, and ankle/foot regions were developed in group consensus. CONCLUSION Although direct MR arthrography has been previously used for a wide variety of clinical indications, the authorship panel recommends more selective application of this minimally invasive procedure. At present, direct MR arthrography remains an important procedure in the armamentarium of the musculoskeletal radiologist and is especially valuable when conventional MRI is indeterminant or results are discrepant with clinical evaluation.
Collapse
Affiliation(s)
- Eric Y Chang
- Radiology Service, VA San Diego Healthcare System, San Diego, CA, USA
- Department of Radiology, University of California, San Diego Medical Center, San Diego, CA, USA
| | - Jenny T Bencardino
- Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, PA, USA
| | - Cristy N French
- Department of Radiology, Penn State Hershey Medical Center, Hummelstown, PA, USA
| | - Jan Fritz
- Department of Radiology, New York University Grossman School of Medicine, New York, NY, USA
| | | | - Zaid Jibri
- GNMI in Mississauga, Greater Toronto Area, Toronto, ON, Canada
| | - Ara Kassarjian
- Department of Radiology, Division of Musculoskeletal Imaging, Olympia Medical Center, Elite Sports Imaging, Madrid, Spain
| | - Kambiz Motamedi
- Department of Radiology, University of California, Los Angeles Medical Center, Los Angeles, CA, USA
| | | | - Colin D Strickland
- Department of Radiology, University of Colorado School of Medicine, Aurora, CO, USA
| | | | - Richard E A Walker
- McCaig Institute for Bone and Joint Health, Calgary, Canada.
- Cumming School of Medicine, University of Calgary, 3280 Hospital Dr NW, Calgary, AB, T2N 4Z6, Canada.
| |
Collapse
|
4
|
Samet JD, Alizai H, Chalian M, Costelloe C, Deshmukh S, Kalia V, Kamel S, Mhuircheartaigh JN, Saade J, Walker E, Wessell D, Fayad LM. Society of skeletal radiology position paper - recommendations for contrast use in musculoskeletal MRI: when is non-contrast imaging enough? Skeletal Radiol 2024; 53:99-115. [PMID: 37300709 DOI: 10.1007/s00256-023-04367-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Revised: 05/01/2023] [Accepted: 05/17/2023] [Indexed: 06/12/2023]
Abstract
The following White Paper will discuss the appropriateness of gadolinium administration in MRI for musculoskeletal indications. Musculoskeletal radiologists should consider the potential risks involved and practice the judicious use of intravenous contrast, restricting administration to cases where there is demonstrable added value. Specific nuances of when contrast is or is not recommended are discussed in detail and listed in table format. Briefly, contrast is recommended for bone and soft tissue lesions. For infection, contrast is reserved for chronic or complex cases. In rheumatology, contrast is recommended for early detection but not for advanced arthritis. Contrast is not recommended for sports injuries, routine MRI neurography, implants/hardware, or spine imaging, but is helpful in complex and post-operative cases.
Collapse
Affiliation(s)
- Jonathan D Samet
- Ann & Robert H. Lurie Children's Hospital of Chicago, Feinberg School of Medicine, Northwestern University, Chicago, USA.
| | - Hamza Alizai
- CHOP Department of Radiology, Children's Hospital of Philadelphia, Philadelphia, USA
| | - Majid Chalian
- Department of Radiology, University of Washington, Seattle, USA
| | | | | | - Vivek Kalia
- Children's Scottish Rite Hospital, Dallas, USA
| | - Sarah Kamel
- Thomas Jefferson University Hospital, Philadelphia, USA
| | | | - Jimmy Saade
- Creighton University School of Medicine, Phoenix Regional Campus, Phoenix, USA
| | - Eric Walker
- Penn State Health Milton S Hershey Medical Center, Hershey, USA
| | - Daniel Wessell
- Mayo Clinic Jacksonville Campus: Mayo Clinic in Florida, Jacksonville, USA
| | - Laura M Fayad
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins Medicine, Baltimore, USA.
| |
Collapse
|
5
|
Jardon M, Fritz J, Samim M. Imaging approach to prosthetic joint infection. Skeletal Radiol 2023:10.1007/s00256-023-04546-7. [PMID: 38133670 DOI: 10.1007/s00256-023-04546-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/01/2023] [Revised: 10/08/2023] [Accepted: 12/07/2023] [Indexed: 12/23/2023]
Abstract
The diagnosis of prosthetic joint infection (PJI) remains challenging, despite multiple available laboratory tests for both serum and synovial fluid analysis. The clinical symptoms of PJI are not always characteristic, particularly in the chronic phase, and there is often significant overlap in symptoms with non-infectious forms of arthroplasty failure. Further exacerbating this challenge is lack of a universally accepted definition for PJI, with publications from multiple professional societies citing different diagnostic criteria. While not included in many of the major societies' guidelines for diagnosis of PJI, diagnostic imaging can play an important role in the workup of suspected PJI. In this article, we will review an approach to diagnostic imaging modalities (radiography, ultrasound, CT, MRI) in the workup of suspected PJI, with special attention to the limitations and benefits of each modality. We will also discuss the role that image-guided interventions play in the workup of these patients, through ultrasound and fluoroscopically guided joint aspirations. While there is no standard imaging algorithm that can universally applied to all patients with suspected PJI, we will discuss a general approach to diagnostic imaging and image-guided intervention in this clinical scenario.
Collapse
Affiliation(s)
- Meghan Jardon
- Department of Radiology, NYU Langone Medical Center, New York, NY, USA.
| | - Jan Fritz
- Department of Radiology, NYU Langone Medical Center, New York, NY, USA
| | - Mohammad Samim
- Department of Radiology, NYU Langone Medical Center, New York, NY, USA
| |
Collapse
|
6
|
Telli T, Desaulniers M, Pyka T, Caobelli F, Forstmann S, Umutlu L, Fendler WP, Rominger A, Herrmann K, Seifert R. What Role Does PET/MRI Play in Musculoskeletal Disorders? Semin Nucl Med 2023:S0001-2998(23)00091-0. [PMID: 38044175 DOI: 10.1053/j.semnuclmed.2023.11.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2023] [Accepted: 11/13/2023] [Indexed: 12/05/2023]
Abstract
Musculoskeletal disorders of nononcological origin are one of the most frequent reasons for consultation. Patients suffering from musculoskeletal disorders also consult more than once for the same reason. This results in multiple clinical follow-ups after several radiological and serum examinations, the main ones including X-rays targeting the painful anatomical region and inflammatory serum parameters. As part of their work up, patients suffering from musculoskeletal disorders often require multisequence, multi-parameter MRI. PET/MRI is a promising imaging modality for their diagnosis, with the added advantage of being able to be performed in a single visit. PET/MRI is particularly useful for diagnosing osteomyelitis, spondylodiscitis, arthritis, many pediatric pathologies, and a wide range of other musculoskeletal pathologies. PET/MRI is already used to diagnose malignant bone tumors such as osteosarcoma. However, current knowledge of the indications for PET/MRI in nononcological musculoskeletal disorders is based on studies involving only a few patients. This review focuses on the usefulness of PET/MRI for diagnosing nononcological musculoskeletal disorders.
Collapse
Affiliation(s)
- Tugce Telli
- Department of Nuclear Medicine, West German Cancer Center, University Hospital Essen, Essen, Germany.
| | - Mélanie Desaulniers
- Department of Nuclear Medicine, West German Cancer Center, University Hospital Essen, Essen, Germany; Department of Nuclear Medicine and Radiobiology, Université de Sherbrooke, Sherbrooke, QC, Canada
| | - Thomas Pyka
- Department of Nuclear Medicine, Inselspital, University Hospital Bern, Bern, Switzerland
| | - Federico Caobelli
- Department of Nuclear Medicine, Inselspital, University Hospital Bern, Bern, Switzerland
| | - Sophia Forstmann
- Department of Anesthesiology and Intensive Care Medicine, University Hospital Essen, Essen, Germany
| | - Lale Umutlu
- Department of Radiology, West German Cancer Center, University Hospital Essen, Essen, Germany
| | - Wolfgang P Fendler
- Department of Nuclear Medicine, West German Cancer Center, University Hospital Essen, Essen, Germany
| | - Axel Rominger
- Department of Nuclear Medicine, Inselspital, University Hospital Bern, Bern, Switzerland
| | - Ken Herrmann
- Department of Nuclear Medicine, West German Cancer Center, University Hospital Essen, Essen, Germany
| | - Robert Seifert
- Department of Nuclear Medicine, West German Cancer Center, University Hospital Essen, Essen, Germany; Department of Nuclear Medicine, Inselspital, University Hospital Bern, Bern, Switzerland
| |
Collapse
|
7
|
Panez-Toro I, Heymann D, Gouin F, Amiaud J, Heymann MF, Córdova LA. Roles of inflammatory cell infiltrate in periprosthetic osteolysis. Front Immunol 2023; 14:1310262. [PMID: 38106424 PMCID: PMC10722268 DOI: 10.3389/fimmu.2023.1310262] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Accepted: 11/13/2023] [Indexed: 12/19/2023] Open
Abstract
Classically, particle-induced periprosthetic osteolysis at the implant-bone interface has explained the aseptic loosening of joint replacement. This response is preceded by triggering both the innate and acquired immune response with subsequent activation of osteoclasts, the bone-resorbing cells. Although particle-induced periprosthetic osteolysis has been considered a foreign body chronic inflammation mediated by myelomonocytic-derived cells, current reports describe wide heterogeneous inflammatory cells infiltrating the periprosthetic tissues. This review aims to discuss the role of those non-myelomonocytic cells in periprosthetic tissues exposed to wear particles by showing original data. Specifically, we discuss the role of T cells (CD3+, CD4+, and CD8+) and B cells (CD20+) coexisting with CD68+/TRAP- multinucleated giant cells associated with both polyethylene and metallic particles infiltrating retrieved periprosthetic membranes. This review contributes valuable insight to support the complex cell and molecular mechanisms behind the aseptic loosening theories of orthopedic implants.
Collapse
Affiliation(s)
- Isidora Panez-Toro
- Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, University of Chile, Independencia, Santiago, Chile
- Nantes Université, Centre National de Recherche Scientifique (CNRS), UMR6286, US2B, Nantes, France
- Institut de Cancérologie de l’Ouest, Tumor Heterogeneity and Precision Medicine Laboratory, Saint-Herblain, France
| | - Dominique Heymann
- Nantes Université, Centre National de Recherche Scientifique (CNRS), UMR6286, US2B, Nantes, France
- Institut de Cancérologie de l’Ouest, Tumor Heterogeneity and Precision Medicine Laboratory, Saint-Herblain, France
- Nantes Université, Laboratory of Histology and Embryology, Medical School, Nantes, France
- The University of Sheffield, Dept of Oncology and Metabolism, Sheffield, United Kingdom
| | - François Gouin
- Department of Surgical Oncology, Centre Léon Bérard, Lyon, France
| | - Jérôme Amiaud
- Nantes Université, Laboratory of Histology and Embryology, Medical School, Nantes, France
| | - Marie-Françoise Heymann
- Nantes Université, Centre National de Recherche Scientifique (CNRS), UMR6286, US2B, Nantes, France
- Institut de Cancérologie de l’Ouest, Tumor Heterogeneity and Precision Medicine Laboratory, Saint-Herblain, France
| | - Luis A. Córdova
- Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, University of Chile, Independencia, Santiago, Chile
- IMPACT, Center of Interventional Medicine for Precision and Advanced Cellular Therapy, Santiago, Chile
- Oral and Maxillofacial Surgery, Clínica MEDS, Santiago, Chile
| |
Collapse
|
8
|
Khodarahmi I, Khanuja HS, Stern SE, Carrino JA, Fritz J. Compressed Sensing SEMAC MRI of Hip, Knee, and Ankle Arthroplasty Implants: A 1.5-T and 3-T Intrapatient Performance Comparison for Diagnosing Periprosthetic Abnormalities. AJR Am J Roentgenol 2023; 221:661-672. [PMID: 37255041 DOI: 10.2214/ajr.23.29380] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
BACKGROUND. The utility of 3-T MRI for diagnosing joint disorders is established, but its performance for diagnosing abnormalities around arthroplasty implants is unclear. OBJECTIVE. The purpose of this study was to compare 1.5-T and 3-T compressed sensing slice encoding for metal artifact correction (SEMAC) MRI for diagnosing peri-prosthetic abnormalities around hip, knee, and ankle arthroplasty implants. METHODS. Forty-five participants (26 women, 19 men; mean age ± SD, 71 ± 14 years) with symptomatic lower extremity arthroplasty (hip, knee, and ankle, 15 each) prospectively underwent consecutive 1.5- and 3-T MRI examinations with intermediate-weighted (IW) and STIR compressed sensing SEMAC sequences. Using a Likert scale, three radiologists evaluated the presence or absence of periprosthetic abnormalities, including bone marrow edema-like signal, osteolysis, stress reaction/fracture, synovitis, and tendon abnormalities and collections; image quality; and visibility of anatomic structures. Statistical analysis included nonparametric comparison and interchangeability testing. RESULTS. For diagnosing periprosthetic abnormalities, 1.5-T and 3-T compressed sensing SEMAC MRI were interchangeable. Across all three joints, 3-T MRI had lower noise than 1.5-T MRI (median IW and STIR scores at 3 T vs 1.5 T, 4 and 4 [range, 2-5 and 3-5] vs 3 and 3 [range, 2-5 and 2-4]; p < .01 for both), sharper edges (median IW and STIR scores at 3 T vs 1.5 T, 4 and 4 [both ranges, 2-5] vs 3 and 3 [range, 2-4 and 2-5]; p < .02 and p < .05), and more effective metal artifact reduction (median IW and STIR scores at 3 T vs 1.5 T, 4 and 4 [range, 3-5 and 2-5] vs 4 and 4 [both ranges, 3-5]; p < .02 and p = .72). Agreement was moderate to substantial for image contrast (IW and STIR, 0.66 and 0.54 [95% CI, 0.41-0.91 and 0.29-0.80]; p = .58 and p = .16) and joint capsule visualization (IW and STIR, 0.57 and 0.70 [range, 0.32-0.81 and 0.51-0.89]; p = .16 and p = .19). The bone-implant interface was more visible at 1.5 T (median IW and STIR scores, 4 and 4 [both ranges, 2-5] at 1.5 T vs 3 and 3 [both ranges, 2-5] at 3 T; p = .08 and p = .58), but periprosthetic tissues had superior visibility at 3 T (IW and STIR, 4 and 4 [both ranges, 3-5] at 3 T vs 4 and 4 [ranges, 2-5 and 3-5] at 1.5 T; p = .07 and p = .19). CONCLUSION. Optimized 1.5-T and 3-T compressed sensing SEMAC MRI are interchangeable for diagnosing periprosthetic abnormalities, although metallic artifacts are larger at 3 T. CLINICAL IMPACT. With compressed sensing SEMAC MRI, lower extremity arthroplasty implants can be imaged at 3 T rather than 1.5 T.
Collapse
Affiliation(s)
- Iman Khodarahmi
- Department of Radiology, NYU Grossman School of Medicine, 660 1st Ave, 3rd Fl, Rm 313, New York, NY 10016
| | - Harpal S Khanuja
- Department of Orthopaedic Surgery, Johns Hopkins School of Medicine, Baltimore, MD
| | - Steven E Stern
- Centre for Data Analytics, Bond University, Gold Coast, Australia
| | - John A Carrino
- Department of Radiology, Hospital for Special Surgery, New York, NY
| | - Jan Fritz
- Department of Radiology, NYU Grossman School of Medicine, 660 1st Ave, 3rd Fl, Rm 313, New York, NY 10016
| |
Collapse
|
9
|
Wissman RD. Editorial Comment: Clinical Impact of Metal Artifact Reduction of Lower Extremity Arthroplasties at 3 T. AJR Am J Roentgenol 2023; 221:672. [PMID: 37377367 DOI: 10.2214/ajr.23.29771] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/29/2023]
|
10
|
Weissman BN, Palestro CJ, Fox MG, Bell AM, Blankenbaker DG, Frick MA, Jawetz ST, Kuo PH, Said N, Stensby JD, Subhas N, Tynus KM, Walker EA, Kransdorf MJ. ACR Appropriateness Criteria® Imaging After Total Hip Arthroplasty. J Am Coll Radiol 2023; 20:S413-S432. [PMID: 38040462 DOI: 10.1016/j.jacr.2023.08.015] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2023] [Accepted: 08/22/2023] [Indexed: 12/03/2023]
Abstract
This article reviews evidence for performing various imaging studies in patients with total hip prostheses. Routine follow-up is generally performed with radiography. Radiographs are also usually the initial imaging modality for patients with symptoms related to the prosthesis. Following acute injury with pain, noncontrast CT may add information to radiographic examination regarding the presence and location of a fracture, component stability, and bone stock. Image-guided joint aspiration, noncontrast MRI, and white blood cell scan and sulfur colloid scan of the hip, are usually appropriate studies for patients suspected of having periprosthetic infection. For evaluation of component loosening, wear, and/or osteolysis, noncontrast CT or MRI are usually appropriate studies. Noncontrast MRI is usually appropriate for identifying adverse reaction to metal debris related to metal-on-metal articulations. For assessing patients after hip arthroplasty, who have trochanteric pain and nondiagnostic radiographs, ultrasound, or MRI are usually appropriate studies. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision process support the systematic analysis of the medical literature from peer reviewed journals. Established methodology principles such as Grading of Recommendations Assessment, Development, and Evaluation or GRADE are adapted to evaluate the evidence. The RAND/UCLA Appropriateness Method User Manual provides the methodology to determine the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where peer reviewed literature is lacking or equivocal, experts may be the primary evidentiary source available to formulate a recommendation.
Collapse
Affiliation(s)
| | | | | | - Angela M Bell
- Rush University Medical Center, Chicago, Illinois; American College of Physicians
| | - Donna G Blankenbaker
- University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin
| | | | | | - Phillip H Kuo
- University of Arizona, Tucson, Arizona; Commission on Nuclear Medicine and Molecular Imaging
| | - Nicholas Said
- Duke University Medical Center, Durham, North Carolina
| | | | | | - Katherine M Tynus
- Northwestern Memorial Hospital, Chicago, Illinois; American College of Physicians
| | - Eric A Walker
- Penn State Milton S. Hershey Medical Center, Hershey, Pennsylvania; Uniformed Services University of the Health Sciences, Bethesda, Maryland
| | | |
Collapse
|
11
|
Sacher SE, Koff MF, Tan ET, Burge A, Potter HG. The role of advanced metal artifact reduction MRI in the diagnosis of periprosthetic joint infection. Skeletal Radiol 2023:10.1007/s00256-023-04483-5. [PMID: 37875571 PMCID: PMC11039568 DOI: 10.1007/s00256-023-04483-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/03/2023] [Revised: 10/09/2023] [Accepted: 10/10/2023] [Indexed: 10/26/2023]
Abstract
Identification and diagnosis of periprosthetic joint infection (PJI) are challenging, requiring a multi-disciplinary approach involving clinical evaluation, laboratory tests, and imaging studies. MRI is advantageous to alternative imaging techniques due to superior soft tissue contrast and absence of ionizing radiation. However, the presence of metallic implants can cause signal loss and artifacts. Metal artifact suppression (MARS) MRI techniques have been developed that mitigate metal artifacts and improve periprosthetic soft tissue visualization. This paper provides a review of the various MARS MRI techniques, their clinical applicability and accuracy in PJI diagnosis and evaluation, and current challenges and future perspectives.
Collapse
Affiliation(s)
- Sara E Sacher
- Department of Radiology and Imaging, Hospital for Special Surgery, 535 East 70th St, New York, NY, 10021, USA.
| | - Matthew F Koff
- Department of Radiology and Imaging, Hospital for Special Surgery, 535 East 70th St, New York, NY, 10021, USA
| | - Ek T Tan
- Department of Radiology and Imaging, Hospital for Special Surgery, 535 East 70th St, New York, NY, 10021, USA
| | - Alissa Burge
- Department of Radiology and Imaging, Hospital for Special Surgery, 535 East 70th St, New York, NY, 10021, USA
| | - Hollis G Potter
- Department of Radiology and Imaging, Hospital for Special Surgery, 535 East 70th St, New York, NY, 10021, USA.
| |
Collapse
|
12
|
Shufen C, Jinmin L, Xiaohui Z, Bin G. Diagnostic value of magnetic resonance imaging for patients with periprosthetic joint infection: a systematic review. BMC Musculoskelet Disord 2023; 24:801. [PMID: 37814241 PMCID: PMC10561437 DOI: 10.1186/s12891-023-06926-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/13/2022] [Accepted: 09/27/2023] [Indexed: 10/11/2023] Open
Abstract
PURPOSE The purpose of this study was to provide a critical systematic review of the role of magnetic resonance imaging (MRI) as a noninvasive method to assess periprosthetic joint infections (PJIs). METHODS The electronic databases PubMed and EMBASE were searched, since their inception up to March 27, 2022. The included studies evaluated the reproducibility and accuracy of MRI features to diagnose PJIs. The article quality assessment was conducted by the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) and Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2). RESULTS Among 1909 studies identified in the initial search, 8 studies were eligible for final systematic review. The included studies evaluated the reproducibility and accuracy of MRI features to diagnose PJIs. Seven of 8 studies showed good to excellent reliability, but only one article among them in which accuracy was evaluated had a low risk of bias. The intraclass correlation coefficient (ICC) and Cohen coefficient (κ) varied between 0.44 and 1.00. The accuracy varied between 63.9% and 94.4%. Potential MRI features, such as lamellated hyperintense synovitis, edema, fluid collection, or lymphadenopathy, might be valuable for diagnosing PJIs. CONCLUSION The quality of the evidence regarding the role of MRI for PJIs diagnosis was low. There is preliminary evidence that MRI has a noteworthy value of distinguishing suspected periprosthetic joint infection in patients with total knee arthroplasty or total hip arthroplasty, but the definition of specific MRI features related to PJIs diagnosis lacks consensus and standardization. Large-scale studies with robust quality were required to help make better clinical decisions in the future.
Collapse
Affiliation(s)
- Chang Shufen
- Department of Orthopaedics, Lanzhou University Second Hospital, 730000, Lanzhou, Gansu, China
- Gansu Province Clinical Research Center for Orthopaedics, Lanzhou, Gansu, China
| | - Liu Jinmin
- Department of Orthopaedics, Lanzhou University Second Hospital, 730000, Lanzhou, Gansu, China
| | - Zhang Xiaohui
- Department of Orthopaedics, Lanzhou University Second Hospital, 730000, Lanzhou, Gansu, China
- Gansu Province Clinical Research Center for Orthopaedics, Lanzhou, Gansu, China
| | - Geng Bin
- Department of Orthopaedics, Lanzhou University Second Hospital, 730000, Lanzhou, Gansu, China.
- Gansu Province Clinical Research Center for Orthopaedics, Lanzhou, Gansu, China.
| |
Collapse
|
13
|
Fleiter TR. Editorial Comment: Photon-Counting Detector CT-The New Era of Routine Quantitative Imaging? AJR Am J Roentgenol 2023; 221:547. [PMID: 37377364 DOI: 10.2214/ajr.23.29774] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/29/2023]
|
14
|
Takahashi T, Takeshita K. Artifact Reduction Proton Density Magnetic Resonance Imaging Can Better Visualize Unicompartmental Knee Arthroplasty Components but Does Not Improve Measurement Accuracy at 3T: An In Vitro Phantom Study. Cureus 2023; 15:e46338. [PMID: 37790872 PMCID: PMC10544766 DOI: 10.7759/cureus.46338] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/01/2023] [Indexed: 10/05/2023] Open
Abstract
Background There are no studies of the efficacy of slice encoding for metal artifact correction (SEMAC) magnetic resonance imaging (MRI) at 3T for patients following unicompartmental knee arthroplasty (UKA), although the artifact is expected to increase compared with 1.5T. Purpose To clarify whether SEMAC MRI can better visualize UKA components and improve measurement accuracy at 3T MRI. Materials and methods The phantom consisted of femoral and tibial standard UKA components embedded in agarose gel. The MR images were scanned on a 3T MR system including proton density (PD) MR images. Six orthopedic surgeons blinded to the size and details of the components independently scored the diagnostic value for measurement and measured the lengths of the femoral posterior condyle, femoral peg, anterior-posterior (AP) tibial component, medial-lateral (ML) tibial component, and tibial keel, with and without SEMAC. Visualization scores were stratified as 0 = definitely nondiagnostic, 1 = probably nondiagnostic, 2 = possibly diagnostic, 3 = probably diagnostic, and 4 = definitely diagnostic. In addition, the differences between actual length and 95% confidence intervals of five measurement points were analyzed. Results The diagnostic values of the posterior condyle (2.0; 1.5 vs. 0; 0) and femoral peg (1.5; 1.0 vs. 0; 0) were significantly better in SEMAC-PD MRI than in non-SEMAC-PD MRI (P<0.05). On the other hand, there were no significant differences in the visualizations of AP, ML, and keel of the tibial components. Measurements of the femoral posterior condyle and tibial keel approached the actual length, but were not involved within the 95% confidence interval (actual length, 19.4 mm vs. 95% CI, 15.7-19.1 mm). Conclusion A significant reduction of metal artifacts was observed only around the femoral component in SEMAC-PD MRI. Despite artifact reduction, this sequence did not result in better visualization for measurement.
Collapse
Affiliation(s)
- Tsuneari Takahashi
- Department of Orthopaedic Surgery, Ishibashi General Hospital, Shimotsuke, JPN
| | | |
Collapse
|
15
|
Rios GM, Lins CF, Quadros Junior MC, Nery RLA, Trindade RMC, Matos MA. Metallic artifact suppression with MAVRIC-SL in magnetic resonance imaging for assessing chronic pain after hip or knee arthroplasty. Radiol Bras 2023; 56:255-262. [PMID: 38204899 PMCID: PMC10775810 DOI: 10.1590/0100-3984.2023.0026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2023] [Revised: 06/11/2023] [Accepted: 07/06/2023] [Indexed: 01/12/2024] Open
Abstract
Objective To analyze the association between osteolysis at the prosthesis interfaces, as determined by magnetic resonance imaging (MRI) with multiacquisition variable-resonance image combination selective (MAVRIC-SL) sequences, and clinical severity after knee or hip arthroplasty, as well as to assess interobserver and intraobserver agreement on periprosthetic bone resorption. Materials and Methods This was a cross-sectional study of 47 patients (49 joints) under postoperative follow-up after knee or hip arthroplasty, with chronic pain, between March 2019 and August 2020. All of the patients completed the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) questionnaire. The component interfaces were evaluated and ordered into two groups: osseointegrated and osteolytic. Nonparametric tests were used. Results There were significant differences between the two groups in terms of the mean WOMAC scores: total (p = 0.010); stiffness domain (p = 0.047); and function (p = 0.011) domains. There was substantial interobserver and intraobserver agreement for most analyses of the components. Conclusion Periprosthetic osteolysis appears to be associated with clinical complaints of pain in the post-arthroplasty scenario, and MAVRIC-SL provides reproducible assessments. It could prove to be an important tool for orthopedists to use in the evaluation of challenging cases of chronic pain after arthroplasty.
Collapse
|
16
|
Fritz J, Rashidi A, de Cesar Netto C. Magnetic Resonance Imaging of Total Ankle Arthroplasty: State-of-The-Art Assessment of Implant-Related Pain and Dysfunction. Foot Ankle Clin 2023; 28:463-492. [PMID: 37536814 DOI: 10.1016/j.fcl.2023.05.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 08/05/2023]
Abstract
Total ankle arthroplasty (TAA) is an effective alternative for treating patients with end-stage ankle degeneration, improving mobility, and providing pain relief. Implant survivorship is constantly improving; however, complications occur. Many causes of pain and dysfunction after total ankle arthroplasty can be diagnosed accurately with clinical examination, laboratory, radiography, and computer tomography. However, when there are no or inconclusive imaging findings, magnetic resonance imaging (MRI) is highly accurate in identifying and characterizing bone resorption, osteolysis, infection, osseous stress reactions, nondisplaced fractures, polyethylene damage, nerve injuries and neuropathies, as well as tendon and ligament tears. Multiple vendors offer effective, clinically available MRI techniques for metal artifact reduction MRI of total ankle arthroplasty. This article reviews the MRI appearances of common TAA implant systems, clinically available techniques and protocols for metal artifact reduction MRI of TAA implants, and the MRI appearances of a broad spectrum of TAA-related complications.
Collapse
Affiliation(s)
- Jan Fritz
- Department of Orthopedic Surgery, Division of Foot and Ankle Surgery, Duke University, Durham, NC, USA.
| | - Ali Rashidi
- Division of Musculoskeletal Radiology, Department of Radiology, NYU Grossman School of Medicine, 660 1st Ave, 3rd Floor, Rm 313, New York, NY 10016, USA
| | - Cesar de Cesar Netto
- Department of Radiology, Molecular Imaging Program at StanDepartment of Radiology, Molecular Imaging Program at Stanford, Stanford University School of Medicine, Stanford, CA, USA
| |
Collapse
|
17
|
Thejeel B, Tan ET, Colucci PG, Gonzalez Della Valle A, Sneag DB. Early perioperative magnetic resonance findings in patients with foot drop following total hip Arthroplasty: A descriptive case-series. Eur J Radiol 2023; 161:110727. [PMID: 36753810 DOI: 10.1016/j.ejrad.2023.110727] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2022] [Revised: 12/09/2022] [Accepted: 01/31/2023] [Indexed: 02/05/2023]
Abstract
PURPOSE This study aims to characterize iatrogenic sciatic nerve injury patterns in the early, perioperative period following posterior-approach total hip arthroplasty (THA) with magnetic resonance imaging (MRI). METHODS This was an IRB-approved retrospective analysis of patients acquired from a longitudinal, single site radiology database of patients who underwent MRI for "foot drop" within 4 weeks following posterior-approach THA surgery, over a 20-year period. RESULTS MRI exams from 51 patients (mean age 62 years; 32 females) who met inclusion criteria were evaluated. Mean time to MRI was 2.4 days. Of 51 patients, 43 underwent primary THA, 6 revision THA and 2 explantation with antibiotic spacer placement. Ten exams revealed a normal appearance of the sciatic nerve. Nineteen showed compression of the sciatic nerve by edema or a fluid collection, without intrinsic nerve abnormality. Fifteen demonstrated perineural tethering or scar/granulation tissue encasement of the nerve, and in half of these cases the sciatic nerve was enlarged and/or hyperintense on fluid-sensitive sequences. Six patients had sciatic nerve compression secondary to quadratus femoris retraction. Six patients had complete resolution of the foot drop at a mean follow-up of 37.3 months following surgery, and in these cases the sciatic nerve appeared normal on the initial postoperative MRI. Remaining patients all had persistent weakness and paresthesias in the sciatic nerve distribution at a mean follow-up duration of 34.3 months. CONCLUSION This retrospective case series demonstrates various sciatic nerve injury patterns in the early perioperative period on MRI and proposes a targeted MRI protocol to evaluate the sciatic nerve post THA surgery.
Collapse
Affiliation(s)
- Bashiar Thejeel
- Department of Radiology and Imaging, Hospital for Special Surgery, 535 E. 70(th) Street, New York, New York 10021, United States.
| | - Ek Tsoon Tan
- Department of Radiology and Imaging, Hospital for Special Surgery, 535 E. 70(th) Street, New York, New York 10021, United States.
| | - Philip G Colucci
- Department of Radiology and Imaging, Hospital for Special Surgery, 535 E. 70(th) Street, New York, New York 10021, United States.
| | - Alejandro Gonzalez Della Valle
- Department of Orthopedic Surgery, Division of Hip and Knee Replacement, Hospital for Special Surgery, 535 E. 70(th) Street, New York, New York 10021, United States.
| | - Darryl B Sneag
- Department of Radiology and Imaging, Hospital for Special Surgery, 535 E. 70(th) Street, New York, New York 10021, United States.
| |
Collapse
|
18
|
Murthy S, Fritz J. Metal Artifact Reduction MRI in the Diagnosis of Periprosthetic Hip Joint Infection. Radiology 2023; 306:e220134. [PMID: 36318029 DOI: 10.1148/radiol.220134] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/22/2023]
Abstract
A 54-year-old woman presented with progressive right hip pain after hip arthroplasty 9 years earlier. The emerging role of metal artifact reduction MRI in the noninvasive diagnosis of infectious synovitis as the surrogate marker for periprosthetic hip joint infection and differentiation from other synovitis types is discussed.
Collapse
Affiliation(s)
- Sindhoora Murthy
- From the Department of Radiology, New York University Grossman School of Medicine, 660 1st Ave, 3rd Floor, Room 313, New York, NY 10016
| | - Jan Fritz
- From the Department of Radiology, New York University Grossman School of Medicine, 660 1st Ave, 3rd Floor, Room 313, New York, NY 10016
| |
Collapse
|
19
|
Particularities on Anatomy and Normal Postsurgical Appearances of the Hip. Radiol Clin North Am 2023; 61:167-190. [PMID: 36739140 DOI: 10.1016/j.rcl.2022.10.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Detailed knowledge of anatomy helps to understand pathologic processes. This article focuses on the anatomy and functionality of the hip, with emphasis on recently studied concepts and anatomic features that have an association with the development of symptoms. The most common anatomic variants posing a challenge for diagnosis and other common findings in asymptomatic patients are reviewed. Good understanding of the different surgical procedures helps in providing as much information as possible to guarantee a favorable outcome, improving prognosis. We review what are the commonly expected postsurgical appearances and the most common postsurgical complications.
Collapse
|
20
|
Xin P, Ni M, Ji Q, Yang X, Geng L, Wang Y, Zhang G. Using mesh in capsule anatomical reconstruction to enhance the stability of high-dislocation-risk hip arthroplasty: a randomized controlled trial. J Orthop Surg Res 2023; 18:102. [PMID: 36788575 PMCID: PMC9926545 DOI: 10.1186/s13018-023-03575-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/10/2022] [Accepted: 02/03/2023] [Indexed: 02/16/2023] Open
Abstract
BACKGROUND Dislocation is a common complication after total hip arthroplasty (THA). This study aimed to compare the outcomes of mesh reconstruction versus conventional capsular repair in maintaining capsular integrity and preventing dislocation after THA. METHODS This was a prospective, randomized controlled study of consecutive patients. A total of 124 high-dislocation-risk THAs were identified and randomized into two groups, one using mesh reconstruction and the other using the conventional capsular repair method. Perioperative data and radiological data were collected. Patients were followed up regularly. The main indices were the capsular integrity assessed by magnetic resonance imaging (MRI) and hip dislocation rate. The secondary indices included the Harris hip score (HHS), complications, and satisfaction. RESULTS A total of 106 patients completed the follow-up and the average follow-up times were 19 ± 3.1 and 18 ± 3.3 months. The operation time of the mesh group was longer than that of the conventional group (P < 0.001). There were minor differences in acetabular anteversion and abduction angle, and the other data showed no differences. MRI results indicated that the success rate of capsular repair was higher in the mesh group (50 hips, 98%) than in the conventional group (37 hips, 67%) (P < 0.001), and the others failed the repair. Three dislocations occurred in the conventional group, while none occurred in the mesh group. The preoperative HHS (30 points) and postoperative HHS (82 points) of the mesh group were similar to those (35 points, 83 points) of the conventional group (P = 0.164, P = 0.328). Satisfaction had no difference (P = 0.532). CONCLUSIONS Compared to conventional repair, mesh reconstruction can effectively maintain capsular integrity and decrease dislocation risk after THA without increasing complications. LEVEL OF EVIDENCE Therapeutic study, Level IA.
Collapse
Affiliation(s)
- Peng Xin
- grid.488137.10000 0001 2267 2324Medical School of Chinese People’s Liberation Army, Beijing, 100853 China ,grid.414252.40000 0004 1761 8894Department of Orthopedics, The First Medical Center of Chinese PLA General Hospital, Fuxing Road, Haidian District, Beijing, 100048 China ,grid.414252.40000 0004 1761 8894Senior Department of Orthopedics, The Fourth Medical Center of Chinese PLA General Hospital, Beijing, 100048 China ,Department of Orthopedics, Chinese PLA Southern Theater Command General Hospital, Guangzhou, 510010 China
| | - Ming Ni
- grid.414252.40000 0004 1761 8894Department of Orthopedics, The First Medical Center of Chinese PLA General Hospital, Fuxing Road, Haidian District, Beijing, 100048 China ,grid.414252.40000 0004 1761 8894Senior Department of Orthopedics, The Fourth Medical Center of Chinese PLA General Hospital, Beijing, 100048 China
| | - Quanbo Ji
- grid.414252.40000 0004 1761 8894Department of Orthopedics, The First Medical Center of Chinese PLA General Hospital, Fuxing Road, Haidian District, Beijing, 100048 China ,grid.414252.40000 0004 1761 8894Senior Department of Orthopedics, The Fourth Medical Center of Chinese PLA General Hospital, Beijing, 100048 China
| | - Xiaoxi Yang
- grid.411642.40000 0004 0605 3760Department of Orthopedics, Peking University Third Hospital, Beijing, 100191 China
| | - Lei Geng
- grid.414252.40000 0004 1761 8894Department of Orthopedics, The First Medical Center of Chinese PLA General Hospital, Fuxing Road, Haidian District, Beijing, 100048 China ,grid.414252.40000 0004 1761 8894Senior Department of Orthopedics, The Fourth Medical Center of Chinese PLA General Hospital, Beijing, 100048 China
| | - Yan Wang
- Department of Orthopedics, The First Medical Center of Chinese PLA General Hospital, Fuxing Road, Haidian District, Beijing, 100048, China. .,Senior Department of Orthopedics, The Fourth Medical Center of Chinese PLA General Hospital, Beijing, 100048, China.
| | - Guoqiang Zhang
- Department of Orthopedics, The First Medical Center of Chinese PLA General Hospital, Fuxing Road, Haidian District, Beijing, 100048, China. .,Senior Department of Orthopedics, The Fourth Medical Center of Chinese PLA General Hospital, Beijing, 100048, China.
| |
Collapse
|
21
|
Sahr ME, Miller TT. Pain After Hip Arthroplasty. Magn Reson Imaging Clin N Am 2023; 31:215-238. [PMID: 37019547 DOI: 10.1016/j.mric.2023.01.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/22/2023]
Abstract
MR imaging and ultrasound (US) have complementary roles for the comprehensive assessment of painful hip arthroplasty. Both modalities demonstrate synovitis, periarticular fluid collections, tendon tears and impingement, and neurovascular impingement, often with features indicating the causative etiology. MR imaging assessment requires technical modifications to reduce metal artifact, such as multispectral imaging, and optimization of image quality, and a high-performance 1.5-T system. US images periarticular structures at high-spatial resolution without interference of metal artifact, permitting real-time dynamic evaluation, and is useful for procedure guidance. Bone complications (periprosthetic fracture, stress reaction, osteolysis, and component loosening) are well depicted on MR imaging.
Collapse
|
22
|
Burke CJ, Fritz J, Samim M. Musculoskeletal Soft-tissue Masses. Magn Reson Imaging Clin N Am 2023; 31:285-308. [PMID: 37019551 DOI: 10.1016/j.mric.2022.10.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/09/2023]
Abstract
Evaluation of soft-tissue masses has become a common clinical practice indication for imaging with both ultrasound and MR imaging. We illustrate the ultrasonography and MR imaging appearances of soft-tissue masses based on the various categories, updates, and reclassifications of the 2020 World Health Organization classification.
Collapse
Affiliation(s)
- Christopher J Burke
- NYU Langone Orthopedic Hospital, 301 East 17th Street, New York, NY 10003, USA.
| | - Jan Fritz
- NYU Langone Orthopedic Hospital, 301 East 17th Street, New York, NY 10003, USA
| | - Mohammad Samim
- NYU Langone Orthopedic Hospital, 301 East 17th Street, New York, NY 10003, USA
| |
Collapse
|
23
|
Thejeel B, Endo Y. Imaging of total hip arthroplasty: part II – imaging of component dislocation, loosening, infection, and soft tissue injury. Clin Imaging 2022; 92:72-82. [DOI: 10.1016/j.clinimag.2022.09.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Revised: 09/22/2022] [Accepted: 09/28/2022] [Indexed: 11/27/2022]
|
24
|
Kassarjian A, Isern-Kebschull J, Tomas X. Postoperative Hip MR Imaging. Magn Reson Imaging Clin N Am 2022; 30:673-688. [DOI: 10.1016/j.mric.2022.03.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022]
|
25
|
Postoperative MRI of the Ankle and Foot. Magn Reson Imaging Clin N Am 2022; 30:733-755. [DOI: 10.1016/j.mric.2022.05.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
26
|
Thejeel B, Endo Y. Imaging of total hip arthroplasty: Part I – Implant design, imaging techniques, and imaging of component wear and fracture. Clin Imaging 2022; 98:74-85. [PMID: 36229386 DOI: 10.1016/j.clinimag.2022.09.008] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2022] [Revised: 09/14/2022] [Accepted: 09/23/2022] [Indexed: 11/17/2022]
Abstract
Despite being one of the most reliable procedures in orthopedic surgery, complications can occur after total hip arthroplasty, and radiology plays an essential role in their evaluation. This article will review the various types of hip arthroplasty and their normal appearances on imaging, followed by mechanisms and imaging appearances of component wear and fracture.
Collapse
Affiliation(s)
- Bashiar Thejeel
- Department of Radiology and Imaging, Hospital for Special Surgery, 535 E. 70th Street, New York, NY 10021, USA
| | - Yoshimi Endo
- Department of Radiology and Imaging, Hospital for Special Surgery, 535 E. 70th Street, New York, NY 10021, USA.
| |
Collapse
|
27
|
Burke CJ, Khodarahmi I, Fritz J. Postoperative MR Imaging of Joints. Magn Reson Imaging Clin N Am 2022; 30:583-600. [DOI: 10.1016/j.mric.2022.03.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022]
|
28
|
Fritz J, Meshram P, Stern SE, Fritz B, Srikumaran U, McFarland EG. Diagnostic Performance of Advanced Metal Artifact Reduction MRI for Periprosthetic Shoulder Infection. J Bone Joint Surg Am 2022; 104:1352-1361. [PMID: 35730745 DOI: 10.2106/jbjs.21.00912] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND The diagnosis of periprosthetic shoulder infection (PSI) in patients with a painful arthroplasty is challenging. Magnetic resonance imaging (MRI) may be helpful, but shoulder implant-induced metal artifacts degrade conventional MRI. Advanced metal artifact reduction (MARS) improves the visibility of periprosthetic bone and soft tissues. The purpose of our study was to determine the reliability, repeatability, and diagnostic performance of advanced MARS-MRI findings for diagnosing PSI. METHODS Between January 2015 and December 2019, we enrolled consecutive patients suspected of having PSI at our academic hospital. All 89 participants had at least 1-year clinical follow-up and underwent standardized clinical, radiographic, and laboratory evaluations and advanced MARS-MRI. Two fellowship-trained musculoskeletal radiologists retrospectively evaluated the advanced MARS-MRI studies for findings associated with PSI in a blinded and independent fashion. Both readers repeated their evaluations after a 2-month interval. Interreader reliability and intrareader repeatability were assessed with κ coefficients. The diagnostic performance of advanced MARS-MRI for PSI was quantified using sensitivity, specificity, and the area under the receiver operating characteristic curve (AUC). When applying the International Consensus Meeting (ICM) 2018 criteria, of the 89 participants, 22 (25%) were deemed as being infected and 67 (75%) were classified as being not infected (unlikely to have PSA and not requiring a surgical procedure during 1-year follow-up). RESULTS The interreader reliability and intrareader repeatability of advanced MARS-MRI findings, including lymphadenopathy, joint effusion, synovitis, extra-articular fluid collection, a sinus tract, rotator cuff muscle edema, and periprosthetic bone resorption, were good (κ = 0.61 to 0.80) to excellent (κ > 0.80). Lymphadenopathy, complex joint effusion, and edematous synovitis had sensitivities of >85%, specificities of >90%, odds ratios of >3.6, and AUC values of >0.90 for diagnosing PSI. The presence of all 3 findings together yielded a PSI probability of >99%, per logistic regression analysis. CONCLUSIONS Our study shows the clinical utility of advanced MARS-MRI for diagnosing PSI when using the ICM 2018 criteria as the reference standard. Although the reliability and diagnostic accuracy were high, these conclusions are based on our specific advanced MARS-MRI protocol interpreted by experienced musculoskeletal radiologists. Investigations with larger sample sizes are needed to confirm these results. LEVEL OF EVIDENCE Diagnostic Level III . See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Jan Fritz
- New York University Grossman School of Medicine, New York University, New York, NY
| | | | - Steven E Stern
- Centre for Data Analytics, Bond University, Gold Coast, Queensland, Australia
| | - Benjamin Fritz
- Department of Radiology, Balgrist University Hospital, Zurich, Switzerland.,Faculty of Medicine, University of Zurich, Zurich, Switzerland
| | - Uma Srikumaran
- Division of Shoulder Surgery, Department of Orthopaedic Surgery, The Johns Hopkins University, Baltimore, Maryland
| | - Edward G McFarland
- Division of Shoulder Surgery, Department of Orthopaedic Surgery, The Johns Hopkins University, Baltimore, Maryland
| |
Collapse
|
29
|
Khodarahmi I, Brinkmann IM, Lin DJ, Bruno M, Johnson PM, Knoll F, Keerthivasan MB, Chandarana H, Fritz J. New-Generation Low-Field Magnetic Resonance Imaging of Hip Arthroplasty Implants Using Slice Encoding for Metal Artifact Correction: First In Vitro Experience at 0.55 T and Comparison With 1.5 T. Invest Radiol 2022; 57:517-526. [PMID: 35239614 PMCID: PMC9363001 DOI: 10.1097/rli.0000000000000866] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES Despite significant progress, artifact-free visualization of the bone and soft tissues around hip arthroplasty implants remains an unmet clinical need. New-generation low-field magnetic resonance imaging (MRI) systems now include slice encoding for metal artifact correction (SEMAC), which may result in smaller metallic artifacts and better image quality than standard-of-care 1.5 T MRI. This study aims to assess the feasibility of SEMAC on a new-generation 0.55 T system, optimize the pulse protocol parameters, and compare the results with those of a standard-of-care 1.5 T MRI. MATERIALS AND METHODS Titanium (Ti) and cobalt-chromium total hip arthroplasty implants embedded in a tissue-mimicking American Society for Testing and Materials gel phantom were evaluated using turbo spin echo, view angle tilting (VAT), and combined VAT and SEMAC (VAT + SEMAC) pulse sequences. To refine an MRI protocol at 0.55 T, the type of metal artifact reduction techniques and the effect of various pulse sequence parameters on metal artifacts were assessed through qualitative ranking of the images by 3 expert readers while taking measured spatial resolution, signal-to-noise ratios, and acquisition times into consideration. Signal-to-noise ratio efficiency and artifact size of the optimized 0.55 T protocols were compared with the 1.5 T standard and compressed-sensing SEMAC sequences. RESULTS Overall, the VAT + SEMAC sequence with at least 6 SEMAC encoding steps for Ti and 9 for cobalt-chromium implants was ranked higher than other sequences for metal reduction ( P < 0.05). Additional SEMAC encoding partitions did not result in further metal artifact reductions. Permitting minimal residual artifacts, low magnetic susceptibility Ti constructs may be sufficiently imaged with optimized turbo spin echo sequences obviating the need for SEMAC. In cross-platform comparison, 0.55 T acquisitions using the optimized protocols are associated with 45% to 64% smaller artifacts than 1.5 T VAT + SEMAC and VAT + compressed-sensing/SEMAC protocols at the expense of a 17% to 28% reduction in signal-to-noise ratio efficiency. B 1 -related artifacts are invariably smaller at 0.55 T than 1.5 T; however, artifacts related to B 0 distortion, although frequently smaller, may appear as signal pileups at 0.55 T. CONCLUSIONS Our results suggest that new-generation low-field SEMAC MRI reduces metal artifacts around hip arthroplasty implants to better advantage than current 1.5 T MRI standard of care. While the appearance of B 0 -related artifacts changes, reduction in B 1 -related artifacts plays a major role in the overall benefit of 0.55 T.
Collapse
Affiliation(s)
- Iman Khodarahmi
- Department of Radiology, New York University Grossman School of Medicine
| | | | - Dana J. Lin
- Department of Radiology, New York University Grossman School of Medicine
| | - Mary Bruno
- Department of Radiology, New York University Grossman School of Medicine
| | | | - Florian Knoll
- Department of Radiology, New York University Grossman School of Medicine
| | | | - Hersh Chandarana
- Department of Radiology, New York University Grossman School of Medicine
| | - Jan Fritz
- Department of Radiology, New York University Grossman School of Medicine
| |
Collapse
|
30
|
Farshad-Amacker NA, Sutter R. The Great Mimickers of Spinal Pathology. Semin Musculoskelet Radiol 2022; 26:439-452. [PMID: 36103886 DOI: 10.1055/s-0042-1748914] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2022]
Abstract
Back pain is one of the leading causes of health costs worldwide, particularly because of the further increased aging population. After clinical examination, spinal imaging is of utmost importance in many patients to reach the correct diagnosis. There are many imaging pitfalls and mimickers of spinal pathology on radiographs, magnetic resonance imaging, and computed tomography. These mimickers may lead to a misdiagnosis or a further imaging work-up if they are not recognized and thus lead to unnecessary examinations and increased health care costs. In this review we present the common mimickers of spinal pathology and describe normal variations when reading imaging studies of the spine.
Collapse
Affiliation(s)
- Nadja A Farshad-Amacker
- Department of Radiology, Balgrist University Hospital, University of Zurich, Zurich, Switzerland
| | - Reto Sutter
- Department of Radiology, Balgrist University Hospital, University of Zurich, Zurich, Switzerland
| |
Collapse
|
31
|
Imaging in Hip Arthroplasty Management Part 2: Postoperative Diagnostic Imaging Strategy. J Clin Med 2022; 11:jcm11154416. [PMID: 35956033 PMCID: PMC9369831 DOI: 10.3390/jcm11154416] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2022] [Revised: 07/20/2022] [Accepted: 07/24/2022] [Indexed: 12/04/2022] Open
Abstract
Hip arthroplasty (HA) is a frequently used procedure with high success rates, but 7% to 27% of the patients complain of persistent postsurgical pain 1 to 4 years post-operation. HA complications depend on the post-operative delay, the type of material used, the patient’s characteristics, and the surgical approach. Radiographs are still the first imaging modality used for routine follow-up, in asymptomatic and painful cases. CT and MRI used to suffer from metallic artifacts but are nowadays central in HA complications diagnosis, both having their advantages and drawbacks. Additionally, there is no consensus on the optimal imaging workup for HA complication diagnosis, which may have an impact on patient management. After a brief reminder about the different types of prostheses, this article reviews their normal and pathologic appearance, according to each imaging modality, keeping in mind that few abnormalities might be present, not anyone requiring treatment, depending on the clinical scenario. A diagnostic imaging workup is also discussed, to aid the therapist in his imaging studies prescription and the radiologist in their practical aspects.
Collapse
|
32
|
Huang C, Chen Y, Ding H, Huang Z, Zhang C, Li W, Liu X, Tu Z, Zhang W, Fang X. Metal Artifact Reduction Sequences MRI: A Useful Reference for Preoperative Diagnosis and Debridement Planning of Periprosthetic Joint Infection. J Clin Med 2022; 11:jcm11154371. [PMID: 35955986 PMCID: PMC9369276 DOI: 10.3390/jcm11154371] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Revised: 07/11/2022] [Accepted: 07/22/2022] [Indexed: 11/26/2022] Open
Abstract
The diagnosis and treatment of periprosthetic joint infection (PJI) is complex and the use of MRI in PJI is gaining attention from orthopedic surgeons as MR technology continues to advance. This study aimed to investigate whether metal artefact reduction sequence (MARS) MRI could be used as an adjunct in the preoperative diagnosis of PJI and to explore its role in PJI debridement planning. From January 2020 to November 2021, participants with metal joint prostheses that needed to be judged for infection were prospectively enrolled. According to Musculoskeletal Infection Society standards, 31 cases were classified as infection, and 20 as non-infection. The sensitivity and specificity of MARS MRI for the diagnosis of PJI were 80.65% and 75%, respectively. In MARS MRI, the incidence of bone destruction, lamellar synovitis, and extracapsular soft tissue oedema were significantly higher in PJI than in non-PJI. Fourteen suspicious occult lesions were found in the preoperative MARS MRI in 9 cases, and the location of 9 infection lesions was confirmed intraoperatively. In conclusion, MARS MRI is an effective diagnostic tool for PJIand can provide a visual reference for preoperative surgical planning.
Collapse
Affiliation(s)
- Changyu Huang
- Department of Orthopedic Surgery, The First Affiliated Hospital of Fujian Medical University, Fuzhou 350000, China; (C.H.); (Y.C.); (H.D.); (Z.H.); (C.Z.); (W.L.)
| | - Yang Chen
- Department of Orthopedic Surgery, The First Affiliated Hospital of Fujian Medical University, Fuzhou 350000, China; (C.H.); (Y.C.); (H.D.); (Z.H.); (C.Z.); (W.L.)
| | - Haiqi Ding
- Department of Orthopedic Surgery, The First Affiliated Hospital of Fujian Medical University, Fuzhou 350000, China; (C.H.); (Y.C.); (H.D.); (Z.H.); (C.Z.); (W.L.)
| | - Zida Huang
- Department of Orthopedic Surgery, The First Affiliated Hospital of Fujian Medical University, Fuzhou 350000, China; (C.H.); (Y.C.); (H.D.); (Z.H.); (C.Z.); (W.L.)
| | - Chaofan Zhang
- Department of Orthopedic Surgery, The First Affiliated Hospital of Fujian Medical University, Fuzhou 350000, China; (C.H.); (Y.C.); (H.D.); (Z.H.); (C.Z.); (W.L.)
| | - Wenbo Li
- Department of Orthopedic Surgery, The First Affiliated Hospital of Fujian Medical University, Fuzhou 350000, China; (C.H.); (Y.C.); (H.D.); (Z.H.); (C.Z.); (W.L.)
| | - Xi Liu
- Department of Radiology and Imaging, The First Affiliated Hospital of Fujian Medical University, Fuzhou 350000, China; (X.L.); (Z.T.)
| | - Zhanhai Tu
- Department of Radiology and Imaging, The First Affiliated Hospital of Fujian Medical University, Fuzhou 350000, China; (X.L.); (Z.T.)
| | - Wenming Zhang
- Department of Orthopedic Surgery, The First Affiliated Hospital of Fujian Medical University, Fuzhou 350000, China; (C.H.); (Y.C.); (H.D.); (Z.H.); (C.Z.); (W.L.)
- Correspondence: (W.Z.); (X.F.)
| | - Xinyu Fang
- Department of Orthopedic Surgery, The First Affiliated Hospital of Fujian Medical University, Fuzhou 350000, China; (C.H.); (Y.C.); (H.D.); (Z.H.); (C.Z.); (W.L.)
- Correspondence: (W.Z.); (X.F.)
| |
Collapse
|
33
|
Metal Artefact Reduction Sequences (MARS) in Magnetic Resonance Imaging (MRI) after Total Hip Arthroplasty (THA). BMC Musculoskelet Disord 2022; 23:620. [PMID: 35764987 PMCID: PMC9238049 DOI: 10.1186/s12891-022-05560-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/15/2021] [Accepted: 06/17/2022] [Indexed: 11/10/2022] Open
Abstract
Background In the past, radiographic imaging was of minor relevance in the diagnosis of periprosthetic joint infections (PJI). Since metal artefact reduction sequences (MARS) are available, magnetic resonance imaging (MRI) has become a promising diagnostic tool for the evaluation of hip arthroplasty implants. The purpose of the present study was to evaluate the efficacy of MARS-MRI in comparison to established diagnostic tools to distinguish between aseptic failure and PJI. Methods From July 2018 to September 2019, 33 patients classified as having an aseptic joint effusion were recruited into the study. The group included 22 women and 11 men with a mean age of 70.4 ± 13.7 (42–88) years. In the same period, 12 patients were classified as having a PJI. The group consisted of 9 women and 3 men with a mean age of 72.5 ± 10.6 (54–88) years. MARS-MRI was conducted using the optimized parameters at 1.5 T in a coronal and axial STIR (short-tau-inversion recovery), a non-fat-saturated T2 in coronal view and a non-fat-saturated T1 in transverse view in 45 patients with painful hip after total hip arthroplasty (THA). Normally distributed continuous data were shown as mean ± standard deviation (SD) and compared using student's t-test. Non-normally distributed continuous data were shown as mean and compared using the Mann–Whitney U test. Results Synovial layering and muscle edema were significant features of periprosthetic joint infection, with sensitivities of 100% and specifities of 63.0—75.0%. The combined specifity and sensitivity levels of synovial layering and muscular edema was 88.0% and 90.0%. Granulomatous synovitis was a significant feature for aseptic failure, with 90.0% sensitivity and 57.0% specifity. Conclusion MARS-MRI is as suitable as standard diagnostic tools to distinguish between aseptic failure and PJI in patients with THA. Further studies with larger patient numbers have to prove whether MARS-MRI could be integral part of PJI diagnostic.
Collapse
|
34
|
Samim M, Khodarahmi I, Burke C, Fritz J. Postoperative Musculoskeletal Imaging and Interventions Following Hip Preservation Surgery, Deformity Correction, and Hip Arthroplasty. Semin Musculoskelet Radiol 2022; 26:242-257. [PMID: 35654093 DOI: 10.1055/s-0041-1740996] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
Total hip arthroplasty and hip preservation surgeries have substantially increased over the past few decades. Musculoskeletal imaging and interventions are cornerstones of comprehensive postoperative care and surveillance in patients undergoing established and more recently introduced hip surgeries. Hence the radiologist's role continues to evolve and expand. A strong understanding of hip joint anatomy and biomechanics, surgical procedures, expected normal postoperative imaging appearances, and postoperative complications ensures accurate imaging interpretation, intervention, and optimal patient care. This article presents surgical principles and procedural details pertinent to postoperative imaging evaluation strategies after common hip surgeries, such as radiography, ultrasonography, computed tomography, and magnetic resonance imaging. We review and illustrate the expected postoperative imaging appearances and complications following chondrolabral repair, acetabuloplasty, osteochondroplasty, periacetabular osteotomy, realigning and derotational femoral osteotomies, and hip arthroplasty.
Collapse
Affiliation(s)
- Mohammad Samim
- Division of Musculoskeletal Radiology, Department of Radiology, NYU Grossman School of Medicine, New York, New York
| | - Iman Khodarahmi
- Division of Musculoskeletal Radiology, Department of Radiology, NYU Grossman School of Medicine, New York, New York
| | - Christopher Burke
- Division of Musculoskeletal Radiology, Department of Radiology, NYU Grossman School of Medicine, New York, New York
| | - Jan Fritz
- Division of Musculoskeletal Radiology, Department of Radiology, NYU Grossman School of Medicine, New York, New York
| |
Collapse
|
35
|
Henkelmann J, Henkelmann R, Denecke T, Zajonz D, Roth A, Sabri O, Purz S. Simultaneous 18F-FDG-PET/MRI for the detection of periprosthetic joint infections after knee or hip arthroplasty: a prospective feasibility study. INTERNATIONAL ORTHOPAEDICS 2022; 46:1921-1928. [PMID: 35635553 PMCID: PMC9372014 DOI: 10.1007/s00264-022-05445-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/07/2022] [Accepted: 05/14/2022] [Indexed: 10/26/2022]
Abstract
Abstract
Purpose
This study investigated the diagnostic value of simultaneous 18F-fluordeoxyglucose positron emission tomography/magnetic resonance imaging (PET/MRI) in suspected periprosthetic joint infection (PJI) of the hip and knee.
Methods
Sixteen prostheses from 13 patients with suspected PJI were prospectively examined using PET/MRI. Image datasets were evaluated in consensus by a radiologist and a nuclear physician for the overall diagnosis of ‘PJI’ (yes/no) and its anatomical involvement, such as the periprosthetic bone margin, bone marrow, and soft tissue. The imaging results were compared with the reference standard obtained from surgical or biopsy specimens and subjected to statistical analysis.
Results
Using the reference standard, ten out of the 13 prostheses (ten hips, threes knees) were diagnosed with PJI. Using PET/MRI, every patient with PJI was correctly diagnosed (sensitivity, 100%; specificity, 100%). Considering the anatomical regions, the sensitivity and specificity were 57% and 50% in the periprosthetic bone margin, 75% and 33% in the bone marrow, and 100% and 100% in the soft tissue.
Conclusion
PET/MRI can be reliably used for the diagnosis of PJI. However, assessment of the periprosthetic bone remains difficult due to the presence of artefacts. Thus, currently, this modality is unlikely to be recommended in clinical practice.
Collapse
|
36
|
Levack AE, Koch C, Moore HG, Cross MB. The Utility of MRI With Multiacquisition Variable-Resonance Image Combination (MAVRIC) in Diagnosing Deep Total Hip Arthroplasty Infection. HSS J 2022; 18:277-283. [PMID: 35645646 PMCID: PMC9096993 DOI: 10.1177/15563316211009203] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/10/2020] [Accepted: 12/04/2020] [Indexed: 02/07/2023]
Abstract
Background: The 2010 American Academy of Orthopaedic Surgeons Clinical Practice Guidelines report insufficient evidence to address the diagnostic efficacy of magnetic resonance imaging (MRI) for periprosthetic joint infection (PJI). Questions/Purposes: The purpose of this study was to determine the utility of MRI with multiacquisition variable-resonance image combination (MAVRIC) metal artifact suppression techniques in diagnosing PJI in the setting of total hip arthroplasty (THA). Methods: Multiacquisition variable-resonance image combination MRIs obtained of THAs between November 2012 and November 2016 were queried. Radiology reports were classified as positive (suspicious for infection), negative (no features of infection), or inconclusive (infection cannot be excluded or correlation with aspiration suggested if clinically concerned). Chart review identified cases of deep PJI according to the modified Musculoskeletal Infection Society criteria. Results: Of 2156 MRIs of THAs included, MRI was concerning for infection in 1.8% (n = 39), inconclusive in 1.2% (n = 26), and negative in 97.0% (n = 2091). Deep PJI was identified in 53 (2.5%) patients, 30 of whom (56.6%) had conclusively positive finding on MRI (false-negative rate: 43.4%, sensitivity: 56.6%). Of 2103 aseptic THAs, only 9 (0.4%) MRIs were read as suspicious for infection (false-positive rate: 0.4%; specificity: 99.6%). Conclusion: Magnetic resonance imaging with MAVRIC is a highly specific test for PJI with a low false-positive rate. This indicates that when clinicians are provided with an MRI that unexpectedly suggests infection, a formal evaluation for infection is indicated. In patients with otherwise equivocal diagnostic findings, MRI may help confirm, but not refute, a diagnosis of PJI. Prospective study with more experienced image reviewers may further support the use of MRI in PJI.
Collapse
Affiliation(s)
- Ashley E. Levack
- Department of Orthopaedic Surgery,
Hospital for Special Surgery, New York, NY, USA
| | - Chelsea Koch
- Department of Orthopaedic Surgery,
Hospital for Special Surgery, New York, NY, USA
| | | | - Michael B. Cross
- Department of Orthopaedic Surgery,
Hospital for Special Surgery, New York, NY, USA
| |
Collapse
|
37
|
Diagnostic Value of Advanced Metal Artifact Reduction Magnetic Resonance Imaging for Periprosthetic Joint Infection. J Comput Assist Tomogr 2022; 46:455-463. [PMID: 35467584 DOI: 10.1097/rct.0000000000001297] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
MATERIALS AND METHODS Magnetic resonance imaging around metal joint prostheses including multiacquisition variable-resonance image combination selective at 1.5 T (from April 2014 to August 2020) was retrospectively evaluated by 2 radiologists for detection of abnormal findings (joint effusion, capsular thickening, pericapsular edema, soft-tissue fluid collection, soft-tissue edema, bone marrow edema pattern around the implant [BME pattern], lymphadenopathy, and others) and overall image impression for PJI. Regarding the soft-tissue fluid collection, presence of communication to the joint or capsular-like structure was evaluated. Clinical assessments were recorded. Positive predictive values (PPVs), negative predictive values (NPVs), and odds ratios (ORs) for PJI were calculated for the abnormal findings. Overall image impression for PJI was evaluated. χ2, Fisher exact, t, and Mann-Whitney U tests and receiver operating characteristic analysis were used. Interobserver agreement was assessed with κ statistics. RESULTS Forty-three joints in 36 patients (mean ± SD age, 75.4 ± 8.8 years; 30 women; hip [n = 29], knee [n = 12], and elbow [n = 2]) were evaluated. Eighteen joints (42%) were clinically diagnosed as PJI. The findings suggesting PJI were capsular thickening (PPV, 70%; NPV, 90%; OR, 20.6), soft-tissue fluid collection (PPV, 81%; NPV, 81%; OR, 19.1), soft-tissue edema (PPV, 67%; NPV, 89%; OR, 17), pericapsular edema (PPV, 76%; NPV, 81%; OR, 13.7), and joint effusion (PPV, 55%; NPV, 100%; OR, 12). Soft-tissue fluid collection without capsular-like structure (PPV, 83%; NPV, 74%; OR, 14.4) or with communication to the joint (PPV, 75%; NPV, 71%; OR, 7.3) suggested PJI. The combinations of joint effusion, capsular thickening, pericapsular edema, soft-tissue fluid collection, and soft-tissue edema highly suggested PJI. Regarding the BME pattern, the combination with soft-tissue edema raised the possibility of PJI (PPV, 73%; NPV, 69%; OR, 5.9). Regarding the interobserver agreements for each abnormal finding, κ values were 0.60 to 0.77. Regarding the overall image impression, weighted κ value was 0.97 and areas under the receiver operating characteristic curve were 0.949 (95% confidence interval, 0.893-1.005) and 0.926 (95% confidence interval, 0.860-0.991) with no significant difference (P = 0.534). CONCLUSIONS The findings suggesting PJI were capsular thickening, soft-tissue fluid collection, soft-tissue edema, pericapsular edema, and joint effusion. The combinations of them highly suggested PJI. Regarding the BME pattern, the combination with soft-tissue edema raised the possibility of PJI.
Collapse
|
38
|
Lin J, Sofka CM, Demetracopoulos CA, Potter HG. The Utility of Isotropic 3D Magnetic Resonance Imaging in Assessing Painful Total Ankle Replacements. FOOT & ANKLE ORTHOPAEDICS 2022; 7:24730114221094840. [PMID: 35520474 PMCID: PMC9067051 DOI: 10.1177/24730114221094840] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Affiliation(s)
- Ji Lin
- Department of Radiology and Imaging, Hospital for Special Surgery, New York, NY, USA
| | - Carolyn M. Sofka
- Department of Radiology and Imaging, Hospital for Special Surgery, New York, NY, USA
| | | | - Hollis G. Potter
- Department of Radiology and Imaging, Hospital for Special Surgery, New York, NY, USA
| |
Collapse
|
39
|
Abstract
Metal-on-metal disease (MOMD) is a rare condition following arthroplasty and has predominantly been reported following hip and knee replacement. Isolated case reports exist with respect to MOMD following total wrist arthroplasty-however, the literature remains limited. Here, we present the history and radiographic and histopathologic features of such a case, and summarize the literature and provide management recommendations.
Collapse
Affiliation(s)
- Christopher J. Rothe
- Gold Coast University Hospital, Southport,
QLD, Australia,Christopher J. Rothe, Gold Coast University
Hospital, 1 Hospital Boulevard, Southport, QLD 4215, Australia.
| | | | | | | |
Collapse
|
40
|
Yan YY, Dous YNB, Ouellette HA, Munk PL, Murray N, Mallinson PI, Sheikh MA. Periarticular calcifications. Skeletal Radiol 2022; 51:451-475. [PMID: 34155550 DOI: 10.1007/s00256-021-03842-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/09/2021] [Revised: 06/12/2021] [Accepted: 06/13/2021] [Indexed: 02/02/2023]
Abstract
Periarticular calcification and ossification is a frequent finding on imaging and may sometimes pose a diagnostic challenge. The differential diagnoses for this radiological finding are wide and can be classified into broad groups such as idiopathic, developmental, trauma, burns, infection, tumor, connective tissue disease, crystalline, metabolic, vascular, and foreign bodies. With careful consideration of the clinical and imaging findings as well as awareness of mimickers of periarticular mineralization, the list of differential diagnoses can be narrowed down. This article aims to review the clinical-radiologic findings of periarticular calcified or ossified lesions with relevant imaging illustrations.
Collapse
Affiliation(s)
- Y Y Yan
- Department of Radiology, Musculoskeletal Section, Vancouver General Hospital, University of British Columbia, Vancouver, BC, Canada. .,Department of Radiology, Changi General Hospital, 2 Simei Street 3, Singapore, 529889, Singapore.
| | - Y N Bin Dous
- Department of Radiology, Musculoskeletal Section, Vancouver General Hospital, University of British Columbia, Vancouver, BC, Canada
| | - H A Ouellette
- Department of Radiology, Musculoskeletal Section, Vancouver General Hospital, University of British Columbia, Vancouver, BC, Canada
| | - P L Munk
- Department of Radiology, Musculoskeletal Section, Vancouver General Hospital, University of British Columbia, Vancouver, BC, Canada
| | - N Murray
- Department of Radiology, Musculoskeletal Section, Vancouver General Hospital, University of British Columbia, Vancouver, BC, Canada
| | - P I Mallinson
- Department of Radiology, Musculoskeletal Section, Vancouver General Hospital, University of British Columbia, Vancouver, BC, Canada
| | - M A Sheikh
- Department of Radiology, Musculoskeletal Section, Vancouver General Hospital, University of British Columbia, Vancouver, BC, Canada
| |
Collapse
|
41
|
Doyle Z, Yoon D, Lee PK, Rosenberg J, Hargreaves BA, Beaulieu CF, Stevens KJ. Clinical utility of accelerated MAVRIC-SL with robust-PCA compared to conventional MAVRIC-SL in evaluation of total hip arthroplasties. Skeletal Radiol 2022; 51:549-556. [PMID: 34223946 PMCID: PMC8727641 DOI: 10.1007/s00256-021-03848-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/23/2021] [Revised: 06/15/2021] [Accepted: 06/20/2021] [Indexed: 02/02/2023]
Abstract
OBJECTIVE To compare the diagnostic performance of a conventional metal artifact suppression sequence MAVRIC-SL (multi-acquisition variable-resonance image combination selective) and a novel 2.6-fold faster sequence employing robust principal component analysis (RPCA), in the MR evaluation of hip implants at 3 T. MATERIALS AND METHODS Thirty-six total hip implants in 25 patients were scanned at 3 T using a conventional MAVRIC-SL proton density-weighted sequence and an RPCA MAVRIC-SL proton density-weighted sequence. Comparison was made of image quality, geometric distortion, visualization around acetabular and femoral components, and conspicuity of abnormal imaging findings using the Wilcoxon signed-rank test and a non-inferiority test. Abnormal findings were correlated with subsequent clinical management and intraoperative findings if the patient underwent subsequent surgery. RESULTS Mean scores for conventional MAVRIC-SL were better than RPCA MAVRIC-SL for all qualitative parameters (p < 0.05), although the probability of RPCA MAVRIC-SL being clinically useful was non-inferior to conventional MAVRIC-SL (within our accepted 10% difference, p < 0.05), except for visualization around the acetabular component. Abnormal imaging findings were seen in 25 hips, and either equally visible or visible but less conspicuous on RPCA MAVRIC-SL in 21 out of 25 cases. In 4 cases, a small joint effusion was queried on MAVRIC-SL but not RPCA MAVRIC-SL, but the presence or absence of a small effusion did not affect subsequent clinical management and patient outcome. CONCLUSION While the overall image quality is reduced, RPCA MAVRIC-SL allows for significantly reduced scan time and maintains almost equal diagnostic performance.
Collapse
Affiliation(s)
- Zoe Doyle
- Department of Radiology, Stanford University, Stanford, CA 94305
| | - Daehyun Yoon
- Department of Radiology, Stanford University, Stanford, CA 94305
| | - Philip K. Lee
- Department of Radiology, Stanford University, Stanford, CA 94305.,Department of Electrical Engineering, Stanford University, Stanford, CA 94305
| | | | - Brian A. Hargreaves
- Department of Radiology, Stanford University, Stanford, CA 94305.,Department of Electrical Engineering, Stanford University, Stanford, CA 94305,Department of Bioengineering, Stanford University, Stanford, CA 94305
| | - Christopher F. Beaulieu
- Department of Radiology, Stanford University, Stanford, CA 94305.,Department of Orthopaedic Surgery, Stanford University, Redwood City, CA 94063
| | - Kathryn J. Stevens
- Department of Radiology, Stanford University, Stanford, CA 94305.,Department of Orthopaedic Surgery, Stanford University, Redwood City, CA 94063
| |
Collapse
|
42
|
Basic and Advanced Metal-Artifact Reduction Techniques at Ultra-High Field 7-T Magnetic Resonance Imaging-Phantom Study Investigating Feasibility and Efficacy. Invest Radiol 2022; 57:387-398. [PMID: 35025835 DOI: 10.1097/rli.0000000000000850] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES The aim of this study was to demonstrate the feasibility and efficacy of basic (increased receive bandwidth) and advanced (view-angle tilting [VAT] and slice-encoding for metal artifact correction [SEMAC]) techniques for metal-artifact reduction in ultra-high field 7-T magnetic resonance imaging (MRI). MATERIALS AND METHODS In this experimental study, we performed 7-T MRI of titanium alloy phantom models composed of a spinal pedicle screw (phantom 1) and an intervertebral cage (phantom 2) centered in a rectangular LEGO frame, embedded in deionized-water-gadolinium (0.1 mmol/L) solution. The following turbo spin-echo sequences were acquired: (1) nonoptimized standard sequence; (2) optimized, that is, increased receive bandwidth sequence (oBW); (3) VAT; (4) combination of oBW and VAT (oBW-VAT); and (5) SEMAC. Two fellowship-trained musculoskeletal radiologists independently evaluated images regarding peri-implant signal void and geometric distortion (a, angle measurement and b, presence of circular shape loss). Statistics included Friedman test and Cochran Q test with Bonferroni correction for multiple comparisons. P values <0.05 were considered to represent statistical significance. RESULTS All metal-artifact reduction techniques reduced peri-implant signal voids and diminished geometric distortions, with oBW-VAT and SEMAC being most efficient. Compared with nonoptimized sequences, oBW-VAT and SEMAC produced significantly smaller peri-implant signal voids (all P ≤ 0.008) and significantly smaller distortion angles (P ≤ 0.001). Only SEMAC could significantly reduce distortions of circular shapes in the peri-implant frame (P ≤ 0.006). Notably, increasing the number of slice-encoding steps in SEMAC sequences did not lead to a significantly better metal-artifact reduction (all P ≥ 0.257). CONCLUSIONS The use of basic and advanced methods for metal-artifact reduction at 7-T MRI is feasible and effective. Both a combination of increased receive bandwidth and VAT as well as SEMAC significantly reduce the peri-implant signal void and geometric distortion around metal implants.
Collapse
|
43
|
Walter SS, Fritz J. MRI of Muscular Neoplasms and Tumor-Like Lesions: A 2020 World Health Organization Classification-based Systematic Review. Semin Roentgenol 2022; 57:252-274. [DOI: 10.1053/j.ro.2022.01.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2021] [Revised: 01/03/2022] [Accepted: 01/08/2022] [Indexed: 11/11/2022]
|
44
|
Bone and Joint Infections: The Role of Imaging in Tailoring Diagnosis to Improve Patients' Care. J Pers Med 2021; 11:jpm11121317. [PMID: 34945789 PMCID: PMC8709091 DOI: 10.3390/jpm11121317] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2021] [Revised: 12/01/2021] [Accepted: 12/02/2021] [Indexed: 12/28/2022] Open
Abstract
Imaging is needed for the diagnosis of bone and joint infections, determining the severity and extent of disease, planning biopsy, and monitoring the response to treatment. Some radiological features are pathognomonic of bone and joint infections for each modality used. However, imaging diagnosis of these infections is challenging because of several overlaps with non-infectious etiologies. Interventional radiology is generally needed to verify the diagnosis and to identify the microorganism involved in the infectious process through imaging-guided biopsy. This narrative review aims to summarize the radiological features of the commonest orthopedic infections, the indications and the limits of different modalities in the diagnostic strategy as well as to outline recent findings that may facilitate diagnosis.
Collapse
|
45
|
Radbruch A, Paech D, Gassenmaier S, Luetkens J, Isaak A, Herrmann J, Othman A, Schäfer J, Nikolaou K. 1.5 vs 3 Tesla Magnetic Resonance Imaging: A Review of Favorite Clinical Applications for Both Field Strengths-Part 2. Invest Radiol 2021; 56:692-704. [PMID: 34417406 DOI: 10.1097/rli.0000000000000818] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
ABSTRACT The second part of this review deals with experiences in neuroradiological and pediatric examinations using modern magnetic resonance imaging systems with 1.5 T and 3 T, with special attention paid to experiences in pediatric cardiac imaging. In addition, whole-body examinations, which are widely used for diagnostic purposes in systemic diseases, are compared with respect to the image quality obtained in different body parts at both field strengths. A systematic overview of the technical differences at 1.5 T and 3 T has been presented in part 1 of this review, as well as several organ-based magnetic resonance imaging applications including musculoskeletal imaging, abdominal imaging, and prostate diagnostics.
Collapse
Affiliation(s)
- Alexander Radbruch
- From the Clinic for Diagnostic and Interventional Neuroradiology, University Hospital Bonn, Bonn
| | - Daniel Paech
- From the Clinic for Diagnostic and Interventional Neuroradiology, University Hospital Bonn, Bonn
| | - Sebastian Gassenmaier
- Department of Radiology, Diagnostic and Interventional Radiology, University of Tübingen, Tübingen
| | - Julian Luetkens
- Clinic for Diagnostic and Interventional Radiology, University Hospital Bonn, Bonn
| | - Alexander Isaak
- Clinic for Diagnostic and Interventional Radiology, University Hospital Bonn, Bonn
| | - Judith Herrmann
- Department of Radiology, Diagnostic and Interventional Radiology, University of Tübingen, Tübingen
| | | | - Jürgen Schäfer
- Department of Radiology, Diagnostic and Interventional Radiology, University of Tübingen, Tübingen
| | - Konstantin Nikolaou
- Department of Radiology, Diagnostic and Interventional Radiology, University of Tübingen, Tübingen
| |
Collapse
|
46
|
Germann C, Nanz D, Sutter R. Magnetic Resonance Imaging Around Metal at 1.5 Tesla: Techniques From Basic to Advanced and Clinical Impact. Invest Radiol 2021; 56:734-748. [PMID: 34074944 DOI: 10.1097/rli.0000000000000798] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
ABSTRACT During the last decade, metal artifact reduction in magnetic resonance imaging (MRI) has been an area of intensive research and substantial improvement. The demand for an excellent diagnostic MRI scan quality of tissues around metal implants is closely linked to the steadily increasing number of joint arthroplasty (especially knee and hip arthroplasties) and spinal stabilization procedures. Its unmatched soft tissue contrast and cross-sectional nature make MRI a valuable tool in early detection of frequently encountered postoperative complications, such as periprosthetic infection, material wear-induced synovitis, osteolysis, or damage of the soft tissues. However, metal-induced artifacts remain a constant challenge. Successful artifact reduction plays an important role in the diagnostic workup of patients with painful/dysfunctional arthroplasties and helps to improve patient outcome. The artifact severity depends both on the implant and the acquisition technique. The implant's material, in particular its magnetic susceptibility and electrical conductivity, its size, geometry, and orientation in the MRI magnet are critical. On the acquisition side, the magnetic field strength, the employed imaging pulse sequence, and several acquisition parameters can be optimized. As a rule of thumb, the choice of a 1.5-T over a 3.0-T magnet, a fast spin-echo sequence over a spin-echo or gradient-echo sequence, a high receive bandwidth, a small voxel size, and short tau inversion recovery-based fat suppression can mitigate the impact of metal artifacts on diagnostic image quality. However, successful imaging of large orthopedic implants (eg, arthroplasties) often requires further optimized artifact reduction methods, such as slice encoding for metal artifact correction or multiacquisition variable-resonance image combination. With these tools, MRI at 1.5 T is now widely considered the modality of choice for the clinical evaluation of patients with metal implants.
Collapse
|
47
|
Khodarahmi I, Fritz J. The Value of 3 Tesla Field Strength for Musculoskeletal Magnetic Resonance Imaging. Invest Radiol 2021; 56:749-763. [PMID: 34190717 DOI: 10.1097/rli.0000000000000801] [Citation(s) in RCA: 45] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
ABSTRACT Musculoskeletal magnetic resonance imaging (MRI) is a careful negotiation between spatial, temporal, and contrast resolution, which builds the foundation for diagnostic performance and value. Many aspects of musculoskeletal MRI can improve the image quality and increase the acquisition speed; however, 3.0-T field strength has the highest impact within the current diagnostic range. In addition to the favorable attributes of 3.0-T field strength translating into high temporal, spatial, and contrast resolution, many 3.0-T MRI systems yield additional gains through high-performance gradients systems and radiofrequency pulse transmission technology, advanced multichannel receiver technology, and high-end surface coils. Compared with 1.5 T, 3.0-T MRI systems yield approximately 2-fold higher signal-to-noise ratios, enabling 4 times faster data acquisition or double the matrix size. Clinically, 3.0-T field strength translates into markedly higher scan efficiency, better image quality, more accurate visualization of small anatomic structures and abnormalities, and the ability to offer high-end applications, such as quantitative MRI and magnetic resonance neurography. Challenges of 3.0-T MRI include higher magnetic susceptibility, chemical shift, dielectric effects, and higher radiofrequency energy deposition, which can be managed successfully. The higher total cost of ownership of 3.0-T MRI systems can be offset by shorter musculoskeletal MRI examinations, higher-quality examinations, and utilization of advanced MRI techniques, which then can achieve higher gains and value than lower field systems. We provide a practice-focused review of the value of 3.0-T field strength for musculoskeletal MRI, practical solutions to challenges, and illustrations of a wide spectrum of gainful clinical applications.
Collapse
Affiliation(s)
- Iman Khodarahmi
- From the Division of Musculoskeletal Radiology, Department of Radiology, NYU Grossman School of Medicine, New York, NY
| | | |
Collapse
|
48
|
Dalili D, Fritz J, Isaac A. 3D MRI of the Hand and Wrist: Technical Considerations and Clinical Applications. Semin Musculoskelet Radiol 2021; 25:501-513. [PMID: 34547815 DOI: 10.1055/s-0041-1731652] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
In the last few years, major developments have been observed in the field of magnetic resonance imaging (MRI). Advances in both scanner hardware and software technologies have witnessed great leaps, enhancing the diagnostic quality and, therefore, the value of MRI. In musculoskeletal radiology, three-dimensional (3D) MRI has become an integral component of the diagnostic pathway at our institutions. This technique is particularly relevant in patients with hand and wrist symptoms, due to the intricate nature of the anatomical structures and the wide range of differential diagnoses for most presentations. We review the benefits of 3D MRI of the hand and wrist, commonly used pulse sequences, clinical applications, limitations, and future directions. We offer guidance for enhancing the image quality and tips for image interpretation of 3D MRI of the hand and wrist.
Collapse
Affiliation(s)
- Danoob Dalili
- Epsom and St Helier University Hospitals, London, United Kingdom
| | - Jan Fritz
- NYU Grossman School of Medicine, New York University, New York, New York
| | - Amanda Isaac
- Guy's and St. Thomas' Hospitals NHS Foundation Trust, London, United Kingdom.,School of Biomedical Engineering and Imaging Sciences, King's College London (KCL), London, United Kingdom
| |
Collapse
|
49
|
Rykov K, Meys TWGM, Knobben BAS, Sietsma MS, Reininga IHF, Ten Have BLEF. MRI Assessment of Muscle Damage After the Posterolateral Versus Direct Anterior Approach for THA (Polada Trial). A Randomized Controlled Trial. J Arthroplasty 2021; 36:3248-3258.e1. [PMID: 34116911 DOI: 10.1016/j.arth.2021.05.009] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/25/2021] [Revised: 04/26/2021] [Accepted: 05/07/2021] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND There is controversy in literature whether the direct anterior approach (DAA) results in less muscle damage compared with the posterolateral approach (PLA) for total hip arthroplasty. The aim of this randomized controlled trial was to assess muscle damage between these two approaches. METHODS Forty-six patients were included. Muscle atrophy, determined with the Goutallier classification, and muscle surface of twelve muscles were analyzed on magnetic resonance imaging images made preoperatively and one year postoperatively. Differences in component placement after DAA or PLA were assessed on radiographs. Harris hip scores and Hip disability and Osteoarthritis and Outcome Score were used as functional outcomes. RESULTS External rotator musculature was damaged in both approaches. After PLA, the obturator muscles showed significantly more atrophy and a decrease in muscle surface. After DAA, the tensor fascia latae showed an increased muscle atrophy and the psoas muscle showed a decreased muscle surface. An increase in muscle surface was seen for the rectus femoris, sartorius, and quadratus femoris after both approaches. The muscle surface of the gluteus medius and iliacus was also increased after PLA. No difference in muscle atrophy was found between the approaches for these muscles. The inclination angle of the cup in PLA was significantly higher. No differences were found in functional outcomes. CONCLUSION Different muscle groups were affected in the two approaches. After PLA, the external rotators were more affected, whereas the tensor fascia latae and psoas muscles were more affected after DAA.
Collapse
Affiliation(s)
- Kyrill Rykov
- Department of Orthopaedic Surgery, Martini Hospital Groningen, the Netherlands
| | - Tim W G M Meys
- Department of Radiology, Martini Hospital Groningen, the Netherlands
| | - Bas A S Knobben
- Department of Orthopaedic Surgery, Martini Hospital Groningen, the Netherlands
| | - Maurits S Sietsma
- Department of Orthopaedic Surgery, Martini Hospital Groningen, the Netherlands
| | - Inge H F Reininga
- Department of Trauma Surgery, University of Groningen, University Medical Center Groningen, the Netherlands
| | - Bas L E F Ten Have
- Department of Orthopaedic Surgery, Martini Hospital Groningen, the Netherlands
| |
Collapse
|
50
|
Moreta J, Cuéllar A, Aguirre U, Casado-Verdugo ÓL, Sánchez A, Cuéllar R. Outside-in arthroscopic psoas release for anterior iliopsoas impingement after primary total hip arthroplasty. Hip Int 2021; 31:649-655. [PMID: 32093495 DOI: 10.1177/1120700020909159] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
PURPOSE 1 of the causes of groin pain after total hip arthroplasty (THA) is impingement of the iliopsoas tendon. The purpose of this study was to present our results with outside-in arthroscopic tenotomy for iliopsoas impingement after THA. METHODS We retrospectively reviewed 12 patients treated between 2009 and 2016 with a minimum follow-up of 2 years. Anterior acetabular component prominence was measured on a true lateral hip radiograph. A transcapsular tenotomy was performed near the edge of the acetabular component through an outside-in arthroscopic approach. The primary clinical outcomes evaluated were groin pain, assessed with a visual analogue scale (VAS), and the Harris Hip Score (HHS). Secondary outcomes included strength of hip flexion, measured with the Medical Research Council (MRC) scale. RESULTS All patients had groin pain improvement, though one patient continued to have moderate pain. The mean VAS score was significantly lower postoperatively (1.08) than preoperatively (6.2) (p < 0.001). The mean HHS improved from 58.8 (range, 37-76) to 86.1 (range, 59-98) (p = 0.001). The average postoperative MRC Scale was 4.58. The mean anterior prominence was 7.25 mm (range 3-12 mm). In patients with <10 mm of component prominence, tenotomy provided groin pain resolution in all cases (n = 8). In patients with ⩾10 mm of prominence, symptoms resolved in 3 out of 4 cases. CONCLUSIONS Outside-in arthroscopic iliopsoas release provided a high rate of success with no complications in this study, even in patients with moderate acetabular component prominence.
Collapse
Affiliation(s)
- Jesús Moreta
- Group of Lower Limb Reconstructive Surgery, Biocruces Bizkaia Health Research Institute, Department of Orthopaedic Surgery and Trauma, Hospital Galdakao-Usansolo, Galdakao, Spain
| | - Adrián Cuéllar
- Department of Orthopaedic Surgery and Trauma, Donostia Universitary Hospital, San Sebastián, Spain
| | - Urko Aguirre
- Research Network on Health Services on Chronic Diseases (REDISSEC), Research Unit, Hospital Galdakao-Usansolo, Galdakao, Spain
| | - Óscar L Casado-Verdugo
- Osatek Alta Tecnología Sanitaria S.A., Department of Magnetic Resonance Imaging, Hospital Galdakao-Usansolo, Galdakao, Spain
| | - Alberto Sánchez
- Group of Lower Limb Reconstructive Surgery, Biocruces Bizkaia Health Research Institute, Department of Orthopaedic Surgery and Trauma, Hospital Galdakao-Usansolo, Galdakao, Spain
| | - Ricardo Cuéllar
- Department of Orthopaedic Surgery and Trauma, Donostia Universitary Hospital, San Sebastián, Spain
| |
Collapse
|