1
|
Xu J, Baliutaviciute V, Swan G, Bowers AR. Driving With Hemianopia X: Effects of Cross Traffic on Gaze Behaviors and Pedestrian Responses at Intersections. Front Hum Neurosci 2022; 16:938140. [PMID: 35898933 PMCID: PMC9309302 DOI: 10.3389/fnhum.2022.938140] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2022] [Accepted: 06/08/2022] [Indexed: 11/13/2022] Open
Abstract
Purpose We conducted a driving simulator study to investigate the effects of monitoring intersection cross traffic on gaze behaviors and responses to pedestrians by drivers with hemianopic field loss (HFL). Methods Sixteen HFL and sixteen normal vision (NV) participants completed two drives in an urban environment. At 30 intersections, a pedestrian ran across the road when the participant entered the intersection, requiring a braking response to avoid a collision. Intersections with these pedestrian events had either (1) no cross traffic, (2) one approaching car from the side opposite the pedestrian location, or (3) two approaching cars, one from each side at the same time. Results Overall, HFL drivers made more (p < 0.001) and larger (p = 0.016) blind- than seeing-side scans and looked at the majority (>80%) of cross-traffic on both the blind and seeing sides. They made more numerous and larger gaze scans (p < 0.001) when they fixated cars on both sides (compared to one or no cars) and had lower rates of unsafe responses to blind- but not seeing-side pedestrians (interaction, p = 0.037). They were more likely to demonstrate compensatory blind-side fixation behaviors (faster time to fixate and longer fixation durations) when there was no car on the seeing side. Fixation behaviors and unsafe response rates were most similar to those of NV drivers when cars were fixated on both sides. Conclusion For HFL participants, making more scans, larger scans and safer responses to pedestrians crossing from the blind side were associated with looking at cross traffic from both directions. Thus, cross traffic might serve as a reminder to scan and provide a reference point to guide blind-side scanning of drivers with HFL. Proactively checking for cross-traffic cars from both sides could be an important safety practice for drivers with HFL.
Collapse
Affiliation(s)
- Jing Xu
- Schepens Eye Research Institute of Massachusetts Eye and Ear, Boston, MA, United States
- Department of Ophthalmology, Harvard Medical School, Boston, MA, United States
- Envision Research Institute, Wichita, KS, United States
- *Correspondence: Jing Xu,
| | - Vilte Baliutaviciute
- Schepens Eye Research Institute of Massachusetts Eye and Ear, Boston, MA, United States
| | - Garrett Swan
- Schepens Eye Research Institute of Massachusetts Eye and Ear, Boston, MA, United States
- Department of Ophthalmology, Harvard Medical School, Boston, MA, United States
| | - Alex R. Bowers
- Schepens Eye Research Institute of Massachusetts Eye and Ear, Boston, MA, United States
- Department of Ophthalmology, Harvard Medical School, Boston, MA, United States
| |
Collapse
|
2
|
Xu J, Emmermann B, Bowers AR. Auditory Reminder Cues to Promote Proactive Scanning on Approach to Intersections in Drivers With Homonymous Hemianopia: Driving With Hemianopia, IX. JAMA Ophthalmol 2021; 140:75-78. [PMID: 34817569 DOI: 10.1001/jamaophthalmol.2021.5007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
Importance Individuals with homonymous hemianopia (HH) are permitted to drive in some jurisdictions. They could compensate for their hemifield vision loss by scanning toward the blind side. However, some drivers with HH do not scan adequately well to the blind side when approaching an intersection, resulting in delayed responses to hazards. Objective To evaluate whether auditory reminder cues promoted proactive scanning on approach to intersections. Design, Setting, and Participants This cross-sectional, single-visit driving simulator study was conducted from October 2018 to May 2019 at a vision rehabilitation research laboratory. A volunteer sample of individuals with HH without visual neglect are included in this analysis. This post hoc analysis was completed in July and August 2020. Main Outcomes and Measures Participants completed drives with and without scanning reminder cues (a single tone from a speaker on the blind side). Scanning was quantified by the percentage of intersections at which an early large scan was made (a scan with a head movement of at least 20° made before 30 m from the intersection). Responses to motorcycle hazards at intersections were quantified by the time to the first fixation and the time to the horn-press response. Results Sixteen individuals were recruited and completed the study. Two were subsequently excluded from analyses. Thus, data from 14 participants (median [IQR] age, 54 [36-66] years; 13 men [93%]) were included. Stroke was the primary cause of the HH (10 participants [71%]). Six (43%) had right-sided HH. Participants were more likely to make an early large scan to the blind side in drives with vs without cues (65% vs 45%; difference, 20% [95% CI, 5%-37%]; P < .001). When participants made an early large scan to the blind side, they were faster to make their first fixation on blind-side motorcycles (mean [SD], 1.77 [1.34] vs 3.88 [1.17] seconds; difference, -2.11 [95% CI, -2.46 to -1.75] seconds; P < .001) and faster to press the horn (mean [SD], 2.54 [1.19] vs 4.54 [1.37] seconds; difference, -2.00 [95% CI, -2.38 to -1.62] seconds; P < .001) than when they did not make an early scan. Conclusions and Relevance This post hoc analysis suggests that auditory reminder cues may promote proactive scanning, which may be associated with faster responses to hazards. This hypothesis should be considered in future prospective studies.
Collapse
Affiliation(s)
- Jing Xu
- Schepens Eye Research Institute of Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, Massachusetts.,Envision Research Institute, Wichita, Kansas
| | | | - Alex R Bowers
- Schepens Eye Research Institute of Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, Massachusetts
| |
Collapse
|
3
|
Hölzl R, Steckhan L, Lehsing C, Savage SW, Bowers AR. Driving with hemianopia VIII: Effects of a vibro-tactile assistance system on safety and gaze behavior in pedestrian crossing situations. SAFETY 2021; 7. [PMID: 34765674 DOI: 10.3390/safety7010018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
People with homonymous visual field defects (HVFDs), the loss of vision in the same half of the visual field in both eyes, are permitted to drive in some jurisdictions. However, the HVFD may cause difficulties in detecting hazards approaching on the side of the field loss (the blind side). An advanced driver assistance system (ADAS) could assist with hazard detection, but little research has been conducted to evaluate the potential benefits of an ADAS for visually impaired drivers. We developed a prototype vibro-tactile assistance system for drivers with HVFDs and conducted a proof-of-concept driving simulation study to evaluate the system. Given that pedestrian accidents are the second most frequent cause of death in road traffic and most of those accidents occur in urban scenarios, we evaluated the potential of the assistance system to improve responses to pedestrian hazards in a city environment. Sixteen participants, of which eight had HVFDs and eight had normal vision, took part. Our analyses evaluated the effects of the driver assistance system, crossing direction and pedestrian behavior on the safety of pedestrian events and the participant's gaze behavior at each of the 256 crossing situations. Generalized linear mixed effects models were used to assess binomial outcome variables. Despite the limited sample size, the results suggest that the vibro-tactile directional warnings were effective in directing the drivers' gaze so that they were looking in the necessary direction before a potential hazard occurred. More time was spent fixating pedestrians on the blind side when the ADAS was engaged and as a result, the safety of street crossings from the blind side improved. The effect of the ADAS was greater on responses to pedestrians from the blind than the seeing side. With an activated ADAS, crossings from the participants' blind sides were as safe as from their seeing sides, and as safe as the crossings when normally-sighted participants were driving. The results suggest that the vibro-tactile ADAS is a promising approach to improve the safety of drivers with HVFD and surrounding traffic.
Collapse
Affiliation(s)
| | | | | | - Steven W Savage
- Schepens Eye Research Institute of Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School
| | - Alex R Bowers
- Schepens Eye Research Institute of Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School
| |
Collapse
|
4
|
Peli E, Vargas-Martin F, Kurukuti NM, Jung JH. Multi-periscopic prism device for field expansion. BIOMEDICAL OPTICS EXPRESS 2020; 11:4872-4889. [PMID: 33014587 PMCID: PMC7510881 DOI: 10.1364/boe.399028] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/03/2020] [Revised: 07/18/2020] [Accepted: 07/20/2020] [Indexed: 05/30/2023]
Abstract
Patients with visual field loss frequently collide with other pedestrians, with the highest risk being from pedestrians at a bearing angle of 45°. Current prismatic field expansion devices (≈30°) cannot cover pedestrians posing the highest risk and are limited by poor image quality and restricted eye scanning range (<5°). A new field expansion device: multi-periscopic prism (MPP); comprising a cascade of half-penta prisms provides wider shifting power (45°) with dramatically better image quality and wider eye scanning range (15°) is presented. Spectacles-mounted MPPs were implemented using 3D printing. The efficacy of the MPP is demonstrated using perimetry, photographic depiction, and analyses of the collision risk covered by the devices.
Collapse
Affiliation(s)
- Eli Peli
- Schepens Eye Research Institute of Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, 20 Staniford St, Boston, MA 02114, USA
| | | | - Nish Mohith Kurukuti
- Schepens Eye Research Institute of Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, 20 Staniford St, Boston, MA 02114, USA
| | - Jae-Hyun Jung
- Schepens Eye Research Institute of Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, 20 Staniford St, Boston, MA 02114, USA
| |
Collapse
|
5
|
Pollock A, Hazelton C, Rowe FJ, Jonuscheit S, Kernohan A, Angilley J, Henderson CA, Langhorne P, Campbell P. Interventions for visual field defects in people with stroke. Cochrane Database Syst Rev 2019; 5:CD008388. [PMID: 31120142 PMCID: PMC6532331 DOI: 10.1002/14651858.cd008388.pub3] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
BACKGROUND Visual field defects are estimated to affect 20% to 57% of people who have had a stroke. Visual field defects can affect functional ability in activities of daily living (commonly affecting mobility, reading and driving), quality of life, ability to participate in rehabilitation, and depression and anxiety following stroke. There are many interventions for visual field defects, which are proposed to work by restoring the visual field (restitution); compensating for the visual field defect by changing behaviour or activity (compensation); substituting for the visual field defect by using a device or extraneous modification (substitution); or ensuring appropriate diagnosis, referral and treatment prescription through standardised assessment or screening, or both. OBJECTIVES To determine the effects of interventions for people with visual field defects after stroke. SEARCH METHODS We searched the Cochrane Stroke Group Trials Register, the Cochrane Eyes and Vision Group Trials Register, CENTRAL, MEDLINE, Embase, CINAHL, AMED, PsycINFO, and PDQT Databse, and clinical trials databases, including ClinicalTrials.gov and WHO Clinical Trials Registry, to May 2018. We also searched reference lists and trials registers, handsearched journals and conference proceedings, and contacted experts. SELECTION CRITERIA Randomised trials in adults after stroke, where the intervention was specifically targeted at improving the visual field defect or improving the ability of the participant to cope with the visual field loss. The primary outcome was functional ability in activities of daily living and secondary outcomes included functional ability in extended activities of daily living, reading ability, visual field measures, balance, falls, depression and anxiety, discharge destination or residence after stroke, quality of life and social isolation, visual scanning, adverse events, and death. DATA COLLECTION AND ANALYSIS Two review authors independently screened abstracts, extracted data and appraised trials. We undertook an assessment of methodological quality for allocation concealment, blinding of outcome assessors, method of dealing with missing data, and other potential sources of bias. We assessed the quality of evidence for each outcome using the GRADE approach. MAIN RESULTS Twenty studies (732 randomised participants, with data for 547 participants with stroke) met the inclusion criteria for this review. However, only 10 of these studies compared the effect of an intervention with a placebo, control, or no treatment group, and eight had data which could be included in meta-analyses. Only two of these eight studies presented data relating to our primary outcome of functional abilities in activities of daily living. One study reported evidence relating to adverse events.Three studies (88 participants) compared a restitutive intervention with a control, but data were only available for one study (19 participants). There was very low-quality evidence that visual restitution therapy had no effect on visual field outcomes, and a statistically significant effect on quality of life, but limitations with these data mean that there is insufficient evidence to draw any conclusions about the effectiveness of restitutive interventions as compared to control.Four studies (193 participants) compared the effect of scanning (compensatory) training with a control or placebo intervention. There was low-quality evidence that scanning training was more beneficial than control or placebo on quality of life, measured using the Visual Function Questionnaire (VFQ-25) (two studies, 96 participants, mean difference (MD) 9.36, 95% confidence interval (CI) 3.10 to 15.62). However, there was low or very-low quality evidence of no effect on measures of visual field, extended activities of daily living, reading, and scanning ability. There was low-quality evidence of no significant increase in adverse events in people doing scanning training, as compared to no treatment.Three studies (166 participants) compared a substitutive intervention (a type of prism) with a control. There was low or very-low quality evidence that prisms did not have an effect on measures of activities of daily living, extended activities of daily living, reading, falls, or quality of life, and very low-quality evidence that they may have an effect on scanning ability (one study, 39 participants, MD 9.80, 95% CI 1.91 to 17.69). There was low-quality evidence of an increased odds of an adverse event (primarily headache) in people wearing prisms, as compared to no treatment.One study (39 participants) compared the effect of assessment by an orthoptist to standard care (no assessment) and found very low-quality evidence that there was no effect on measures of activities of daily living.Due to the quality and quantity of evidence, we remain uncertain about the benefits of assessment interventions. AUTHORS' CONCLUSIONS There is a lack of evidence relating to the effect of interventions on our primary outcome of functional ability in activities of daily living. There is limited low-quality evidence that compensatory scanning training may be more beneficial than placebo or control at improving quality of life, but not other outcomes. There is insufficient evidence to reach any generalised conclusions about the effect of restitutive interventions or substitutive interventions (prisms) as compared to placebo, control, or no treatment. There is low-quality evidence that prisms may cause minor adverse events.
Collapse
Affiliation(s)
- Alex Pollock
- Nursing, Midwifery and Allied Health Professions Research Unit, Glasgow Caledonian University, 6th Floor, Govan Mbeki Building, Cowcaddens Road, Glasgow, UK, G4 0BA
| | | | | | | | | | | | | | | | | |
Collapse
|
6
|
Qiu C, Jung JH, Tuccar-Burak M, Spano L, Goldstein R, Peli E. Measuring Pedestrian Collision Detection With Peripheral Field Loss and the Impact of Peripheral Prisms. Transl Vis Sci Technol 2018; 7:1. [PMID: 30197833 PMCID: PMC6126965 DOI: 10.1167/tvst.7.5.1] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2017] [Accepted: 06/26/2018] [Indexed: 11/24/2022] Open
Abstract
Purpose Peripheral field loss (PFL) due to retinitis pigmentosa, choroideremia, or glaucoma often results in a highly constricted residual central field, which makes it difficult for patients to avoid collision with approaching pedestrians. We developed a virtual environment to evaluate the ability of patients to detect pedestrians and judge potential collisions. We validated the system with both PFL patients and normally sighted subjects with simulated PFL. We also tested whether properly placed high-power prisms may improve pedestrian detection. Methods A virtual park-like open space was rendered using a driving simulator (configured for walking speeds), and pedestrians in testing scenarios appeared within and outside the residual central field. Nine normally sighted subjects and eight PFL patients performed the pedestrian detection and collision judgment tasks. The performance of the subjects with simulated PFL was further evaluated with field of view expanding prisms. Results The virtual system for testing pedestrian detection and collision judgment was validated. The performance of PFL patients and normally sighted subjects with simulated PFL were similar. The prisms for simulated PFL improved detection rates, reduced detection response times, and supported reasonable collision judgments in the prism-expanded field; detections and collision judgments in the residual central field were not influenced negatively by the prisms. Conclusions The scenarios in a virtual environment are suitable for evaluating PFL and the impact of field of view expanding devices. Translational Relevance This study validated an objective means to evaluate field expansion devices in reproducible near-real-life settings.
Collapse
Affiliation(s)
- Cheng Qiu
- Schepens Eye Research Institute, Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, MA, USA
| | - Jae-Hyun Jung
- Schepens Eye Research Institute, Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, MA, USA
| | - Merve Tuccar-Burak
- Schepens Eye Research Institute, Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, MA, USA
| | - Lauren Spano
- Schepens Eye Research Institute, Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, MA, USA
| | - Robert Goldstein
- Schepens Eye Research Institute, Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, MA, USA
| | - Eli Peli
- Schepens Eye Research Institute, Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, MA, USA
| |
Collapse
|
7
|
Houston KE, Peli E, Goldstein RB, Bowers AR. Driving With Hemianopia VI: Peripheral Prisms and Perceptual-Motor Training Improve Detection in a Driving Simulator. Transl Vis Sci Technol 2018; 7:5. [PMID: 29359111 PMCID: PMC5772830 DOI: 10.1167/tvst.7.1.5] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2017] [Accepted: 10/15/2017] [Indexed: 11/24/2022] Open
Abstract
Purpose Drivers with homonymous hemianopia (HH) were previously found to have impaired detection of blind-side hazards, yet in many jurisdictions they may obtain a license. We evaluated whether oblique 57Δ peripheral prisms (p-prisms) and perceptual-motor training improved blind-side detection rates. Methods Patients with HH (n = 11) wore p-prisms for 2 weeks and then received perceptual-motor training (six visits) detecting and touching stimuli in the prism-expanded vision. In a driving simulator, patients drove and pressed the horn upon detection of pedestrians who ran toward the roadway (26 from each side): (1) without p-prisms at baseline; (2) with p-prisms after 2 weeks acclimation but before training; (3) with p-prisms after training; and (4) 3 months later. Results P-prisms improved blind-side detection from 42% to 56%, which further improved after training to 72% (all P < 0.001). Blind-side timely responses (adequate time to have stopped) improved from 31% without to 44% with p-prisms (P < 0.001) and further improved with training to 55% (P = 0.02). At the 3-month follow-up, improvements from training were maintained for detection (65%; P = 0.02) but not timely responses (P = 0.725). There was wide between-subject variability in baseline detection performance and response to p-prisms. There were no negative effects of p-prisms on vehicle control or seeing-side performance. Conclusions P-prisms improved detection with no negative effects, and training may provide additional benefit. Translational Relevance In jurisdictions where people with HH are legally driving, these data aid in clinical decision making by providing evidence that p-prisms improve performance without negative effects.
Collapse
Affiliation(s)
- Kevin E Houston
- Schepens Eye Research Institute, Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, MA, USA
| | - Eli Peli
- Schepens Eye Research Institute, Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, MA, USA
| | - Robert B Goldstein
- Schepens Eye Research Institute, Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, MA, USA
| | - Alex R Bowers
- Schepens Eye Research Institute, Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, MA, USA
| |
Collapse
|
8
|
Bowers AR, Dickinson C, Peli E. Comments about outcome measures for clinical trials of interventions for post-stroke patients with hemianopia. Acta Neurol Scand 2017; 136:548-550. [PMID: 28980309 DOI: 10.1111/ane.12770] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- A. R. Bowers
- Schepens Eye Research Institute, Massachusetts Eye and Ear; Harvard Medical School; Boston MA USA
| | - C. Dickinson
- Division of Pharmacy and Optometry; School of Heath Sciences; Faculty of Biology, Medicine and Health; Manchester Academic Health Science Centre; University of Manchester; Manchester UK
| | - E. Peli
- Schepens Eye Research Institute, Massachusetts Eye and Ear; Harvard Medical School; Boston MA USA
| |
Collapse
|
9
|
Alberti CF, Goldstein RB, Peli E, Bowers AR. Driving with Hemianopia V: Do Individuals with Hemianopia Spontaneously Adapt Their Gaze Scanning to Differing Hazard Detection Demands? Transl Vis Sci Technol 2017; 6:11. [PMID: 29067219 PMCID: PMC5652967 DOI: 10.1167/tvst.6.5.11] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2017] [Accepted: 09/06/2017] [Indexed: 11/24/2022] Open
Abstract
Purpose We investigated whether people with homonymous hemianopia (HH) were able to spontaneously (without training or instructions) adapt their blind-side scan magnitudes in response to differing scanning requirements for detection of pedestrians in a driving simulator when differing cues about pedestrian eccentricities and movement behaviors were available in the seeing hemifield. Methods Twelve HH participants completed two sessions in a driving simulator pressing the horn when they detected a pedestrian. Stationary pedestrians outside the driving lane were presented in one session and approaching pedestrians on a collision course in the other. Gaze data were analyzed for pedestrians initially appearing at approximately 14° in the blind hemifield. No instructions were given regarding scanning. Results After appearing, the stationary pedestrians' eccentricity increased rapidly to a median of 31° after 2.5 seconds, requiring increasingly larger blind-side gaze scans for detection, while the approaching pedestrians' eccentricity remained constant at approximately 14°, requiring a more moderate scan (∼14°) for detection. Although median scan magnitudes did not differ between the two conditions (approaching: 14° [IQR 9°–15°]; stationary: 13° [IQR 9°–20°]; P = 0.43), three participants showed evidence of adapting (increasing) their blind-side scan magnitudes in the stationary condition. Conclusions Three participants (25%) appeared to be able to apply voluntary cognitive control to modify their blind-side gaze scanning in response to the differing scanning requirements of the two conditions without explicit training. Translational Relevance Our results suggest that only a minority of people with hemianopia are likely to be able to spontaneously adapt their blind-side scanning in response to rapidly changing and unpredictable situations in on-road driving.
Collapse
Affiliation(s)
- Concetta F Alberti
- Department of Psychology, College of Science, Northeastern University, Boston, MA, USA
| | - Robert B Goldstein
- Schepens Eye Research Institute, Massachusetts Eye and Ear, Harvard Medical School, Boston, MA, USA
| | - Eli Peli
- Schepens Eye Research Institute, Massachusetts Eye and Ear, Harvard Medical School, Boston, MA, USA
| | - Alex R Bowers
- Schepens Eye Research Institute, Massachusetts Eye and Ear, Harvard Medical School, Boston, MA, USA
| |
Collapse
|
10
|
Abstract
PURPOSE Prisms used for field expansion are limited by the optical scotoma at a prism apex (apical scotoma). For a patient with two functioning eyes, fitting prisms unilaterally allows the other eye to compensate for the apical scotoma. A monocular patient's field loss cannot be expanded with a conventional or Fresnel prism because of the apical scotoma. A newly invented optical device, the multiplexing prism (MxP), was developed to overcome the apical scotoma limitation in monocular field expansion. METHODS A Fresnel-prism-like device with alternating prism and flat elements superimposes shifted and see-through views, thus creating the (monocular) visual confusion required for field expansion and eliminating the apical scotoma. Several implementations are demonstrated and preliminarily evaluated for different monocular conditions with visual field loss. The field expansion of the MxP is compared with the effect of conventional prisms using calculated and measured perimetry. RESULTS Field expansion without apical scotomas is shown to be effective for monocular patients with hemianopia or constricted peripheral field. The MxPs are shown to increase the nasal field for a patient with only one eye and for patients with bitemporal hemianopia. The MxPs placed at the far temporal field are shown to expand the normal visual field. The ability to control the contrast ratio between the two images is verified. CONCLUSIONS A novel optical device is demonstrated to have the potential for field expansion technology in a variety of conditions. The devices may be inexpensive and can be constructed in a cosmetically acceptable format.
Collapse
|
11
|
Abstract
Purpose Horizontal peripheral prisms for hemianopia provide field expansion above and below the horizontal meridian; however, there is a vertical gap leaving the central area (important for driving) without expansion. In the oblique design, tilting the bases of both prism segments toward the horizontal meridian moves the field expansion area vertically and centrally (closing the central gap) while the prisms remain in the peripheral location. However, tilting the prisms results also in a reduction of the lateral field expansion. Higher prism powers are needed to counter this effect. Methods We developed, implemented, and tested a series of designs aimed at increasing the prism power to reduce the central gap while maintaining wide lateral expansion. The designs included inserting the peripheral prisms into carrier lenses that included yoked prism in the opposite direction, combination of two Fresnel segments attached at the base and angled to each other (bi-part prisms), and creating Fresnel prism–like segments from nonparallel periscopic mirror pairs (reflective prisms). Results A modest increase in lateral power was achieved with yoked-prism carriers. Bi-part combination of 36Δ Fresnel segments provided high power with some reduction in image quality. Fresnel reflective prism segments have potential for high power with superior optical quality but may be limited in field extent or by interruptions of the expanded field. Extended apical scotomas, even with unilateral fitting, may limit the utility of very high power prisms. The high-power bi-part and reflective prisms enable a wider effective eye scanning range (more than 15 degrees) into the blind hemifield. Conclusions Conventional prisms of powers higher than the available 57Δ are limited by the binocular impact of a wider apical scotoma and a reduced effective eye scanning range to the blind side. The various designs that we developed may overcome these limitations and find use in various other field expansion applications.
Collapse
|
12
|
Abstract
Visual impairments are common after traumatic brain injury (TBI) and negatively affect quality of life. We describe a 39-year-old woman with a severe TBI who was evaluated by the inpatient optometry and vision rehabilitation service with findings of complete right homonymous hemianopia and right cranial nerve III palsy with 30-degree right exotropia (eye turn out) and complete right ptosis (eyelid will not open). The 30-degree exotropia advantageously generated 30 degrees of right visual field expansion when the right ptosis was treated with a magnetic levator prosthesis, which restores eyelid opening. Once opened, the patient used visual field expansion derived from a right exotropia to overcome functional impairments caused by right hemianopia. Field expansion improved the patient's wheelchair mobility and reaching tasks during inpatient therapy. This is the first report of visual field expansion by strabismus facilitated by correction of ptosis. Strabismus should be considered for its potential field expansion benefits when homonymous visual deficits are present, before considering patching. A multidisciplinary vision rehabilitation team is well suited to make this determination.
Collapse
|
13
|
Bowers AR. Driving with homonymous visual field loss: a review of the literature. Clin Exp Optom 2016; 99:402-18. [PMID: 27535208 DOI: 10.1111/cxo.12425] [Citation(s) in RCA: 39] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2015] [Revised: 02/02/2016] [Accepted: 02/26/2016] [Indexed: 01/13/2023] Open
Abstract
Driving is an important rehabilitation goal for patients with homonymous field defects (HFDs); however, whether or not people with HFDs should be permitted to drive is not clear. Over the last 15 years, there has been a marked increase in the number of studies evaluating the effects of HFDs on driving performance. This review of the literature provides a much-needed summary for practitioners and researchers, addressing the following topics: regulations pertaining to driving with HFDs, self-reported driving difficulties, pass rates in on-road tests, the effects of HFDs on lane position and steering stability, the effects of HFDs on scanning and detection of potential hazards, screening for potential fitness to drive, evaluating practical fitness to drive and the efficacy of interventions to improve driving of persons with HFDs. Although there is clear evidence from on-road studies that some people with HFDs may be rated as safe to drive, others are reported to have significant deficits in skills important for safe driving, including taking a lane position too close to one side of the travel lane, unstable steering and inadequate viewing (scanning) behaviour. Driving simulator studies have provided strong evidence of a wide range in compensatory scanning abilities and detection performance, despite similar amounts of visual field loss. Conventional measurements of visual field extent (in which eye movements are not permitted) do not measure such compensatory abilities and are not predictive of on-road driving performance. Thus, there is a need to develop better tests to screen people with HFDs for visual fitness to drive. We are not yet at a point where we can predict which HFD patient is likely to be a safe driver. Therefore, it seems only fair to provide an opportunity for individualised assessments of practical fitness to drive either on the road and/or in a driving simulator.
Collapse
Affiliation(s)
- Alex R Bowers
- Schepens Eye Research Institute, Massachusetts Eye and Ear, Harvard Medical School, Boston, Massachusetts, USA.
| |
Collapse
|
14
|
Houston KE, Bowers AR, Fu X, Liu R, Goldstein RB, Churchill J, Wiegand JP, Soo T, Tang Q, Peli E. A Pilot Study of Perceptual-Motor Training for Peripheral Prisms. Transl Vis Sci Technol 2016; 5:9. [PMID: 26933522 PMCID: PMC4771076 DOI: 10.1167/tvst.5.1.9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2015] [Accepted: 07/22/2015] [Indexed: 11/24/2022] Open
Abstract
Purpose Peripheral prisms (p-prisms) shift peripheral portions of the visual field of one eye, providing visual field expansion for patients with hemianopia. However, patients rarely show adaption to the shift, incorrectly localizing objects viewed within the p-prisms. A pilot evaluation of a novel computerized perceptual-motor training program aiming to promote p-prism adaption was conducted. Methods Thirteen patients with hemianopia fitted with 57Δ oblique p-prisms completed the training protocol. They attended six 1-hour visits reaching and touching peripheral checkerboard stimuli presented over videos of driving scenes while fixating a central target. Performance was measured at each visit and after 3 months. Results There was a significant reduction in touch error (P = 0.01) for p-prism zone stimuli from pretraining median of 16.6° (IQR 12.1°–19.6°) to 2.7° ( IQR 1.0°–8.5°) at the end of training. P-prism zone reaction times did not change significantly with training (P > 0.05). P-prism zone detection improved significantly (P = 0.01) from a pretraining median 70% (IQR 50%–88%) to 95% at the end of training (IQR 73%–98%). Three months after training improvements had regressed but performance was still better than pretraining. Conclusions Improved pointing accuracy for stimuli detected in prism-expanded vision of patients with hemianopia wearing 57Δ oblique p-prisms is possible and training appears to further improve detection. Translational Relevance This is the first use of this novel software to train adaptation of visual direction in patients with hemianopia wearing peripheral prisms.
Collapse
Affiliation(s)
- Kevin E Houston
- Schepens Eye Research Institute, Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, MA, USA
| | - Alex R Bowers
- Schepens Eye Research Institute, Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, MA, USA
| | - Xianping Fu
- Schepens Eye Research Institute, Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, MA, USA ; Information Science and Technology College, Dalian Maritime University, Dalian, China
| | - Rui Liu
- Schepens Eye Research Institute, Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, MA, USA ; Ophthalmology Department, Eye and ENT Hospital of Fudan University, Shanghai, China
| | - Robert B Goldstein
- Schepens Eye Research Institute, Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, MA, USA
| | - Jeff Churchill
- Schepens Eye Research Institute, Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, MA, USA
| | - Jean-Paul Wiegand
- Schepens Eye Research Institute, Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, MA, USA
| | - Tim Soo
- Schepens Eye Research Institute, Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, MA, USA
| | - Qu Tang
- Schepens Eye Research Institute, Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, MA, USA
| | - Eli Peli
- Schepens Eye Research Institute, Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, MA, USA
| |
Collapse
|
15
|
Dundon NM, Bertini C, Làdavas E, Sabel BA, Gall C. Visual rehabilitation: visual scanning, multisensory stimulation and vision restoration trainings. Front Behav Neurosci 2015; 9:192. [PMID: 26283935 PMCID: PMC4515568 DOI: 10.3389/fnbeh.2015.00192] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2015] [Accepted: 07/09/2015] [Indexed: 12/16/2022] Open
Abstract
Neuropsychological training methods of visual rehabilitation for homonymous vision loss caused by postchiasmatic damage fall into two fundamental paradigms: “compensation” and “restoration”. Existing methods can be classified into three groups: Visual Scanning Training (VST), Audio-Visual Scanning Training (AViST) and Vision Restoration Training (VRT). VST and AViST aim at compensating vision loss by training eye scanning movements, whereas VRT aims at improving lost vision by activating residual visual functions by training light detection and discrimination of visual stimuli. This review discusses the rationale underlying these paradigms and summarizes the available evidence with respect to treatment efficacy. The issues raised in our review should help guide clinical care and stimulate new ideas for future research uncovering the underlying neural correlates of the different treatment paradigms. We propose that both local “within-system” interactions (i.e., relying on plasticity within peri-lesional spared tissue) and changes in more global “between-system” networks (i.e., recruiting alternative visual pathways) contribute to both vision restoration and compensatory rehabilitation, which ultimately have implications for the rehabilitation of cognitive functions.
Collapse
Affiliation(s)
- Neil M Dundon
- Department of Psychology, University of Bologna Bologna, Italy ; Centre for Studies and Research in Cognitive Neuroscience, University of Bologna Cesena, Italy
| | - Caterina Bertini
- Department of Psychology, University of Bologna Bologna, Italy ; Centre for Studies and Research in Cognitive Neuroscience, University of Bologna Cesena, Italy
| | - Elisabetta Làdavas
- Department of Psychology, University of Bologna Bologna, Italy ; Centre for Studies and Research in Cognitive Neuroscience, University of Bologna Cesena, Italy
| | - Bernhard A Sabel
- Medical Faculty, Institute of Medical Psychology, Otto-von-Guericke University of Magdeburg Magdeburg, Germany
| | - Carolin Gall
- Medical Faculty, Institute of Medical Psychology, Otto-von-Guericke University of Magdeburg Magdeburg, Germany
| |
Collapse
|
16
|
Abstract
PURPOSE Unilateral peripheral prisms for homonymous hemianopia (HH) expand the visual field through peripheral binocular visual confusion, a stimulus for binocular rivalry that could lead to reduced predominance and partial suppression of the prism image, thereby limiting device functionality. Using natural-scene images and motion videos, we evaluated whether detection was reduced in binocular compared with monocular viewing. METHODS Detection rates of nine participants with HH or quadranopia and normal binocularity wearing peripheral prisms were determined for static checkerboard perimetry targets briefly presented in the prism expansion area and the seeing hemifield. Perimetry was conducted under monocular and binocular viewing with targets presented over videos of real-world driving scenes and still frame images derived from those videos. RESULTS With unilateral prisms, detection rates in the prism expansion area were significantly lower in binocular than in monocular (prism eye) viewing on the motion background (medians, 13 and 58%, respectively, p = 0.008) but not the still frame background (medians, 63 and 68%, p = 0.123). When the stimulus for binocular rivalry was reduced by fitting prisms bilaterally in one HH and one normally sighted subject with simulated HH, prism-area detection rates on the motion background were not significantly different (p > 0.6) in binocular and monocular viewing. CONCLUSIONS Conflicting binocular motion appears to be a stimulus for reduced predominance of the prism image in binocular viewing when using unilateral peripheral prisms. However, the effect was only found for relatively small targets. Further testing is needed to determine the extent to which this phenomenon might affect the functionality of unilateral peripheral prisms in more real-world situations.
Collapse
|
17
|
Abstract
Stroke is the most common cause of homonymous hemianopia (HH) in adults, followed by trauma and tumors. Associated signs and symptoms, as well as visual field characteristics such as location and congruity, can help determine the location of the causative brain lesion. HH can have a significant effect on quality of life, including problems with driving, reading, or navigation. This can result in decreased independence, inability to enjoy leisure activities, and injuries. Understanding these restrictions, as well as the management options, can aid in making the best use of remaining vision. Treatment options include prismatic correction to expand the remaining visual field, compensatory training to improve visual search abilities, and vision restoration therapy to improve the vision itself. Spontaneous recovery can occur within the first months. However, because spontaneous recovery does not always occur, methods of reducing visual disability play an important role in the rehabilitation of patients with HH.
Collapse
Affiliation(s)
- Denise Goodwin
- Pacific University College of Optometry, Forest Grove, OR, USA
| |
Collapse
|
18
|
Bowers AR, Keeney K, Peli E. Randomized crossover clinical trial of real and sham peripheral prism glasses for hemianopia. JAMA Ophthalmol 2014; 132:214-22. [PMID: 24201760 DOI: 10.1001/jamaophthalmol.2013.5636] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
IMPORTANCE There is a major lack of randomized controlled clinical trials evaluating the efficacy of prismatic treatments for hemianopia. Evidence for their effectiveness is mostly based on anecdotal case reports and open-label evaluations without a control condition. OBJECTIVE To evaluate the efficacy of real relative to sham peripheral prism glasses for patients with complete homonymous hemianopia. DESIGN, SETTING, AND PARTICIPANTS Double-masked, randomized crossover trial at 13 study sites, including the Peli laboratory at Schepens Eye Research Institute, 11 vision rehabilitation clinics in the United States, and 1 in the United Kingdom. Patients were 18 years or older with complete homonymous hemianopia for at least 3 months and without visual neglect or significant cognitive decline. INTERVENTION Patients were allocated by minimization into 2 groups. One group received real (57-prism diopter) oblique and sham (<5-prism diopter) horizontal prisms; the other received real horizontal and sham oblique, in counterbalanced order. Each crossover period was 4 weeks. MAIN OUTCOMES AND MEASURES The primary outcome was the overall difference, across the 2 periods of the crossover, between the proportion of participants who wanted to continue with (said yes to) real prisms and the proportion who said yes to sham prisms. The secondary outcome was the difference in perceived mobility improvement between real and sham prisms. RESULTS Of 73 patients randomized, 61 completed the crossover. A significantly higher proportion said yes to real than sham prisms (64% vs 36%; odds ratio, 5.3; 95% CI, 1.8-21.0). Participants who continued wear after 6 months reported greater improvement in mobility with real than sham prisms at crossover end (P = .002); participants who discontinued wear reported no difference. CONCLUSIONS AND RELEVANCE Real peripheral prism glasses were more helpful for obstacle avoidance when walking than sham glasses, with no differences between the horizontal and oblique designs. Peripheral prism glasses provide a simple and inexpensive mobility rehabilitation intervention for hemianopia. TRIAL REGISTRATION clinicaltrials.gov Identifier: NCT00494676.
Collapse
Affiliation(s)
- Alex R Bowers
- Schepens Eye Research Institute, Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, Massachusetts
| | | | - Eli Peli
- Schepens Eye Research Institute, Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, Massachusetts
| |
Collapse
|
19
|
Bowers AR, Ananyev E, Mandel AJ, Goldstein RB, Peli E. Driving with hemianopia: IV. Head scanning and detection at intersections in a simulator. Invest Ophthalmol Vis Sci 2014; 55:1540-8. [PMID: 24474265 DOI: 10.1167/iovs.13-12748] [Citation(s) in RCA: 42] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
PURPOSE Using a driving simulator, we examined the effects of homonymous hemianopia (HH) on head scanning behaviors at intersections and evaluated the role of inadequate head scanning in detection failures. METHODS Fourteen people with complete HH and without cognitive decline or visual neglect and 12 normally sighted (NV) current drivers participated. They drove in an urban environment following predetermined routes, which included multiple intersections. Head scanning behaviors were quantified at T-intersections (n = 32) with a stop or yield sign. Participants also performed a pedestrian detection task. The relationship between head scanning and detection was examined at 10 intersections. RESULTS For HH drivers, the first scan was more likely to be toward the blind than the seeing hemifield. They also made a greater proportion of head scans overall to the blind side than did the NV drivers to the corresponding side (P = 0.003). However, head scan magnitudes of HH drivers were smaller than those of the NV group (P < 0.001). Drivers with HH had impaired detection of blind-side pedestrians due either to not scanning in the direction of the pedestrian or to an insufficient scan magnitude (left HH detected only 46% and right HH 8% at the extreme left and right of the intersection, respectively). CONCLUSIONS Drivers with HH demonstrated compensatory head scan patterns, but not scan magnitudes. Inadequate scanning resulted in blind-side detection failures, which might place HH drivers at increased risk for collisions at intersections. Scanning training tailored to specific problem areas identified in this study might be beneficial.
Collapse
Affiliation(s)
- Alex R Bowers
- Schepens Eye Research Institute, Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, Massachusetts
| | | | | | | | | |
Collapse
|
20
|
Kasneci E, Sippel K, Aehling K, Heister M, Rosenstiel W, Schiefer U, Papageorgiou E. Driving with binocular visual field loss? A study on a supervised on-road parcours with simultaneous eye and head tracking. PLoS One 2014; 9:e87470. [PMID: 24523869 PMCID: PMC3921141 DOI: 10.1371/journal.pone.0087470] [Citation(s) in RCA: 61] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2013] [Accepted: 12/24/2013] [Indexed: 11/30/2022] Open
Abstract
Post-chiasmal visual pathway lesions and glaucomatous optic neuropathy cause binocular visual field defects (VFDs) that may critically interfere with quality of life and driving licensure. The aims of this study were (i) to assess the on-road driving performance of patients suffering from binocular visual field loss using a dual-brake vehicle, and (ii) to investigate the related compensatory mechanisms. A driving instructor, blinded to the participants' diagnosis, rated the driving performance (passed/failed) of ten patients with homonymous visual field defects (HP), including four patients with right (HR) and six patients with left homonymous visual field defects (HL), ten glaucoma patients (GP), and twenty age and gender-related ophthalmologically healthy control subjects (C) during a 40-minute driving task on a pre-specified public on-road parcours. In order to investigate the subjects' visual exploration ability, eye movements were recorded by means of a mobile eye tracker. Two additional cameras were used to monitor the driving scene and record head and shoulder movements. Thus this study is novel as a quantitative assessment of eye movements and an additional evaluation of head and shoulder was performed. Six out of ten HP and four out of ten GP were rated as fit to drive by the driving instructor, despite their binocular visual field loss. Three out of 20 control subjects failed the on-road assessment. The extent of the visual field defect was of minor importance with regard to the driving performance. The site of the homonymous visual field defect (HVFD) critically interfered with the driving ability: all failed HP subjects suffered from left homonymous visual field loss (HL) due to right hemispheric lesions. Patients who failed the driving assessment had mainly difficulties with lane keeping and gap judgment ability. Patients who passed the test displayed different exploration patterns than those who failed. Patients who passed focused longer on the central area of the visual field than patients who failed the test. In addition, patients who passed the test performed more glances towards the area of their visual field defect. In conclusion, our findings support the hypothesis that the extent of visual field per se cannot predict driving fitness, because some patients with HVFDs and advanced glaucoma can compensate for their deficit by effective visual scanning. Head movements appeared to be superior to eye and shoulder movements in predicting the outcome of the driving test under the present study scenario.
Collapse
Affiliation(s)
- Enkelejda Kasneci
- Computer Engineering Department, Wilhelm-Schickard-Institute of Computer Science, University of Tübingen, Tübingen, Germany
- * E-mail:
| | - Katrin Sippel
- Computer Engineering Department, Wilhelm-Schickard-Institute of Computer Science, University of Tübingen, Tübingen, Germany
| | - Kathrin Aehling
- Centre for Ophthalmology, Institute for Ophthalmic Research, University of Tübingen, Tübingen, Germany
| | - Martin Heister
- Centre for Ophthalmology, Institute for Ophthalmic Research, University of Tübingen, Tübingen, Germany
| | - Wolfgang Rosenstiel
- Computer Engineering Department, Wilhelm-Schickard-Institute of Computer Science, University of Tübingen, Tübingen, Germany
| | - Ulrich Schiefer
- Centre for Ophthalmology, Institute for Ophthalmic Research, University of Tübingen, Tübingen, Germany
- Competence Centre “Vision Research”, Study Course “Ophthalmic Optics/Audiology”, University of Applied Sciences Aalen, Aalen, Germany
| | - Elena Papageorgiou
- Centre for Ophthalmology, Institute for Ophthalmic Research, University of Tübingen, Tübingen, Germany
- Department of Ophthalmology, University of Leicester, Leicester Royal Infirmary, Leicester, United Kingdom
| |
Collapse
|
21
|
Alberti CF, Peli E, Bowers AR. Driving with hemianopia: III. Detection of stationary and approaching pedestrians in a simulator. Invest Ophthalmol Vis Sci 2014; 55:368-74. [PMID: 24346175 DOI: 10.1167/iovs.13-12737] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
PURPOSE To compare blind-side detection performance of drivers with homonymous hemianopia (HH) for stationary and approaching pedestrians, initially appearing at small (4°) or large (14°) eccentricities in a driving simulator. While the stationary pedestrians did not represent an imminent threat, as their eccentricity increased rapidly as the vehicle advanced, the approaching pedestrians maintained a collision course with approximately constant eccentricity, walking or running, toward the travel lane as if to cross. METHODS Twelve participants with complete HH and without spatial neglect pressed the horn whenever they detected a pedestrian while driving along predetermined routes in two driving simulator sessions. Miss rates and reaction times were analyzed for 52 stationary and 52 approaching pedestrians. RESULTS Miss rates were higher and reaction times longer on the blind than the seeing side (P < 0.01). On the blind side, miss rates were lower for approaching than stationary pedestrians (16% vs. 29%, P = 0.01), especially at larger eccentricities (20% vs. 54%, P = 0.005), but reaction times for approaching pedestrians were longer (1.72 vs. 1.41 seconds; P = 0.03). Overall, the proportion of potential blind-side collisions (missed and late responses) was not different for the two paradigms (41% vs. 35%, P = 0.48), and significantly higher than for the seeing side (3%, P = 0.002). CONCLUSIONS In a realistic pedestrian detection task, drivers with HH exhibited significant blind-side detection deficits. Even when approaching pedestrians were detected, responses were often too late to avoid a potential collision.
Collapse
Affiliation(s)
- Concetta F Alberti
- Schepens Eye Research Institute, Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, Massachusetts
| | | | | |
Collapse
|
22
|
Jung JH, Peli E. Impact of high power and angle of incidence on prism corrections for visual field loss. OPTICAL ENGINEERING (REDONDO BEACH, CALIF.) 2014; 53:10.1117/1.OE.53.6.061707. [PMID: 24497649 PMCID: PMC3909527 DOI: 10.1117/1.oe.53.6.061707] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
Prism distortions and spurious reflections are not usually considered when prescribing prisms to compensate for visual field loss due to homonymous hemianopia. Distortions and reflections in the high power Fresnel prisms used in peripheral prism placement can be considerable, and the simplifying assumption that prism deflection power is independent of angle of incidence into the prisms results in substantial errors. We analyze the effects of high prism power and incidence angle on the field expansion, size of the apical scotomas, and image compression/expansion. We analyze and illustrate the effects of reflections within the Fresnel prisms, primarily due to reflections at the bases, and secondarily due to surface reflections. The strength and location of these effects differs materially depending on whether the serrated prismatic surface is placed toward or away from the eye, and this affects the contribution of the reflections to visual confusion, diplopia, false alarms, and loss of contrast. We conclude with suggestions for controlling and mitigating these effects in clinical practice.
Collapse
Affiliation(s)
- Jae-Hyun Jung
- Schepens Eye Research Institute, Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, MA 02114-2500, USA, ,
| | - Eli Peli
- Schepens Eye Research Institute, Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, MA 02114-2500, USA, ,
| |
Collapse
|
23
|
Bronstad PM, Bowers AR, Albu A, Goldstein RB, Peli E. Central visual field loss and driving--reply. JAMA Ophthalmol 2013; 131:819-21. [PMID: 23764712 PMCID: PMC5542396 DOI: 10.1001/jamaophthalmol.2013.4259] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/27/2024]
|
24
|
Apfelbaum HL, Ross NC, Bowers AR, Peli E. Considering Apical Scotomas, Confusion, and Diplopia When Prescribing Prisms for Homonymous Hemianopia. Transl Vis Sci Technol 2013; 2:2. [PMID: 24049719 DOI: 10.1167/tvst.2.4.2] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2012] [Accepted: 04/02/2013] [Indexed: 11/24/2022] Open
Abstract
PURPOSE While prisms are commonly prescribed for homonymous hemianopia to extend or expand the visual field, they cause potentially troubling visual side effects, including nonveridical location of perceived images, diplopia, and visual confusion. In addition, the field behind a prism at its apex is lost to an apical scotoma equal in magnitude to the amount of prism shift. The perceptual consequences of apical scotomas and the other effects of various designs were examined to consider parameters and designs that can mitigate the impact of these effects. METHODS Various configurations of sector and peripheral prisms were analyzed, in various directions of gaze, and their visual effects were illustrated using simulated perimetry. A novel "percept" diagram was developed that yielded insights into the patient's view through the prisms. The predictions were verified perimetrically with patients. RESULTS The diagrams distinguish between potentially beneficial field expansion via visual confusion and the pericentrally disturbing and useless effect of diplopia, and their relationship to prism power and gaze direction. They also illustrate the nonexpanding substitution of field segments of some popular prism designs. CONCLUSIONS Yoked sector prisms have no effect at primary gaze or when gaze is directed toward the seeing hemifield, and they introduce pericentral field loss when gaze is shifted into them. When fitted unilaterally, sector prisms also have an effect only when the gaze is directed into the prism and may cause a pericentral scotoma and/or central diplopia. Peripheral prisms are effective at essentially all gaze angles. Since gaze is not directed into them, they avoid problematic pericentral effects. We derive useful recommendations for prism power and position parameters, including novel ways of fitting prisms asymmetrically. TRANSLATIONAL RELEVANCE Clinicians will find these novel diagrams, diagramming techniques, and analyses valuable when prescribing prismatic aids for hemianopia and when designing new prism devices for patients with various types of field loss.
Collapse
Affiliation(s)
- Henry L Apfelbaum
- Schepens Eye Research Institute, Massachusetts Eye and Ear, Harvard Medical School, Boston, MA
| | | | | | | |
Collapse
|