1
|
Sheibani P, Ahmadizenous G, Esmaeili B, Bijani A. Effect of computer-aided design/computer-aided manufacturing bleach shade ceramic thickness on its light transmittance and microhardness of light-cured resin cement. Dent Res J (Isfahan) 2024; 21:44. [PMID: 39376258 PMCID: PMC11457981] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2023] [Revised: 04/05/2024] [Accepted: 04/14/2024] [Indexed: 10/09/2024] Open
Abstract
Background This study aimed to measure light transmittance (LT) through various thicknesses of computer-aided design/computer-aided manufacturing bleach shade ceramics and to assess the Vickers microhardness (VMH) of underlying light-cured resin cement. Materials and Methods In this in vitro study, a total of 90 ceramic discs (VITA Mark II [VM], VITA Suprinity, and CELTRA Duo) were prepared in 0.5, 1, and 1.5 mm thicknesses. To measure LT, the Valo light-curing unit was placed in direct contact with the ceramics on the radiometer. The average LT was recorded after three measurements. In addition, 90 specimens of light-cured resin cement (Allcem Veneer) were cured in Teflon molds (0.5 mm in depth) beneath ceramic pieces. Ten specimens of resin cement were also cured without the presence of ceramic as a control group. VMH of the cement specimens was reported. The data were analyzed by one-way analysis of variance and multiple comparison tests (α =0.05) in SPSS version 17. Results In each ceramic group, LT was negatively related to ceramic thickness (P < 0.05). At a thickness of 1.5 mm among all ceramic types, the VMH of resin cement was significantly decreased (P < 0.05). In all thicknesses, the VMH of resin cement was lower significantly than the control group, except for the thickness of 0.5 mm of VM. Conclusion According to the results of this study, light-cured cement is not a suitable option for cementing the studied bleach shade ceramics. Furthermore, the thickness of the ceramic has a significant effect on LT (P < 0.05), unlike VMH.
Collapse
Affiliation(s)
- Pardis Sheibani
- Dental Materials Research Center, Student Research Committee, Babol University of Medical Sciences, Babol, Iran
| | - Ghazaleh Ahmadizenous
- Dental Materials Research Center, Health Research Institute, Babol University of Medical Sciences, Babol, Iran
| | - Behnaz Esmaeili
- Dental Materials Research Center, Health Research Institute, Babol University of Medical Sciences, Babol, Iran
| | - Ali Bijani
- Social Determinants of Health Center, Health Research Institute, Babol University of Medical Sciences, Babol, Iran
| |
Collapse
|
2
|
Chou YC, Chuang SF, Lin JC, Li CL, Liu BY, Lee CL. Application of near-infrared-to-blue upconversion luminescence for the polymerization of resin cements through zirconia discs. Dent Mater 2024; 40:1208-1215. [PMID: 38851964 DOI: 10.1016/j.dental.2024.06.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2024] [Revised: 06/02/2024] [Accepted: 06/03/2024] [Indexed: 06/10/2024]
Abstract
OBJECTIVES To investigate a near-infrared-to-blue luminescence upconversion curing method for polymerizing resin cements under zirconia discs. METHODS Lava zirconia discs of different thicknesses (0.5-2.0 mm) were manufactured. First, the transmittances of the NIR and two blue lights (BLs) (LED and halogen lights) through these discs were measured. Second, NaYF4:Yb3+/Tm3+ upconversion phosphor (UP) powder was milled into 0.5-μm particle sizes. A light-curable resin cement VariolinkII base was chosen as the control (UP0), and an experimental cement (UP5) was prepared by adding 5 % UPs. These two cements were examined using multiphoton excitation microscopy for particle distribution. UP5 and UP0 were polymerized with or without zirconia shielding then subjected to a microhardness test. A multifold analysis was performed to examine the effects of zirconia thickness, curing protocols (pure BL or combined BL and NIR curing), and cement type. RESULTS The transmittance of NIR was superior to that of BL through zirconia discs of all thicknesses. UP particles were homogeneously distributed in UP5 and emitted blue luminescence under 980-nm NIR excitation. UP5 showed higher microhardness values than UP0 under any curing protocol or zirconia shielding condition. The combination of 20-s BL and 40-s NIR curing yielded the highest microhardness in uncovered UP5. However, combining 40-s BL and 20-s NIR curing surpassed the other groups when the zirconia discs were thicker than 0.5 mm. SIGNIFICANCE NIR exhibits higher transmission through zirconia than BL. UP particles work as strengthen fillers and photosensitizers in cements. NIR upconversion curing could be a new strategy for polymerizing resin cements under thick zirconia restorations.
Collapse
Affiliation(s)
- Yu-Cheng Chou
- School of Dentistry and Institute of Oral Medicine, National Cheng Kung University, Tainan, Taiwan; Department of Stomatology, National Cheng Kung University Hospital, Tainan, Taiwan
| | - Shu-Fen Chuang
- School of Dentistry and Institute of Oral Medicine, National Cheng Kung University, Tainan, Taiwan; Department of Stomatology, National Cheng Kung University Hospital, Tainan, Taiwan.
| | - Jui-Che Lin
- Department of Chemical Engineering, National Cheng Kung University, Tainan, Taiwan
| | - Chia-Ling Li
- School of Dentistry and Institute of Oral Medicine, National Cheng Kung University, Tainan, Taiwan
| | - Bang-Yan Liu
- School of Dentistry and Institute of Oral Medicine, National Cheng Kung University, Tainan, Taiwan
| | - Chung-Lin Lee
- Department of Stomatology, National Cheng Kung University Hospital, Tainan, Taiwan
| |
Collapse
|
3
|
Aldryhim H, El-Mowafy O, McDermott P, Prakki A. Hardness of Resin Cements Polymerized through Glass-Ceramic Veneers. Dent J (Basel) 2021; 9:dj9080092. [PMID: 34436004 PMCID: PMC8394743 DOI: 10.3390/dj9080092] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2021] [Revised: 07/26/2021] [Accepted: 08/02/2021] [Indexed: 11/28/2022] Open
Abstract
(1) Background: The aim of this study is to evaluate the hardness of resin cements polymerized through ceramic disks under different process factors (ceramic type and thickness, light-polymerization units and polymerization time); (2) Method: Three types of ceramic blocks were used (IPS e.max CAD; Celtra Duo; VITABLOCS). Ceramic disks measuring 0.5 mm, 1.0 mm and 1.5 mm were cut from commercial blocks. Two resin cements (Rely X Veneer and Variolink Esthetic) were polymerized through the ceramic specimens using distinct light-polymerization units (Deep-cure; Blue-phase) and time intervals (10 and 20 s). Hardness of cement specimens was measured using microhardness tester with a Knoop indenter. Data were statistically analyzed using factorial ANOVA (α = 5%); (3) Results: Mean microhardness of Rely X Veneer cement was significantly higher than that of Variolink Esthetic. Deep-cure resulted in higher mean microhardness values compared to Blue-phase at 0.5- and 1-mm specimen thicknesses. Moreover, a direct correlation was found between polymerization time and hardness of resin cement; (4) Conclusions: Surface hardness was affected by resin cement type and ceramic thickness, and not affected by ceramic types, within evaluated conditions. Increasing light-polymerization time significantly increased the hardness of the cement.
Collapse
Affiliation(s)
- Hanan Aldryhim
- Faculty of Dentistry, Princess Nourah Bint Abdulrahman University, Riyadh 11564, Saudi Arabia
- Correspondence:
| | - Omar El-Mowafy
- Faculty of Dentistry, University of Toronto, Toronto, ON M5G 1G6, Canada; (O.E.-M.); (P.M.); (A.P.)
| | - Peter McDermott
- Faculty of Dentistry, University of Toronto, Toronto, ON M5G 1G6, Canada; (O.E.-M.); (P.M.); (A.P.)
| | - Anuradha Prakki
- Faculty of Dentistry, University of Toronto, Toronto, ON M5G 1G6, Canada; (O.E.-M.); (P.M.); (A.P.)
| |
Collapse
|
4
|
Borges LPS, Borges GA, Correr AB, Platt JA, Kina S, Correr-Sobrinho L, Costa AR. Effect of lithium disilicate ceramic thickness, shade and translucency on transmitted irradiance and knoop microhardness of a light cured luting resin cement. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2021; 32:90. [PMID: 34338911 PMCID: PMC8328902 DOI: 10.1007/s10856-021-06562-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/01/2020] [Accepted: 07/13/2021] [Indexed: 06/02/2023]
Abstract
This in vitro study evaluates the influence of pressed lithium disilicate thickness, shade and translucency on the transmitted irradiance and the Knoop microhardness (KHN) of a light-cured resin cement at two depths. One hundred and thirty-five ceramic discs of IPS e.max Press (Ivoclar Vivadent) were fabricated and divided into twenty-seven groups (n = 5) according to the association between translucency: HT (hight translucency), LT (low translucency), and MO (medium opacity); shade: BL2, A1 and A3.5; and thickness: 0.5 mm, 1.5 mm, and 2.0 mm. One side of each ceramic disc was finished, polished and glazed. The irradiance (mW/cm²) of a multiwave LED light curing unit (Valo, Ultradent) was evaluated with a potentiometer (Ophir 10ª-V2-SH, Ophir Optronics) without (control group) or with interposition of ceramic samples. The microhardness of Variolink Esthetic LC resin cement (Ivoclar Vivadent) was evaluated after 24 h at two depths (100 μm and 700 μm). Data were submitted to ANOVA followed by Tukey's test (α = 0.05). Irradiance and KHN were significantly influenced by ceramic thickness (p < 0.0001), shade (p < 0.001), translucency (p < 0.0001) and depth (p < 0.0001). Conclusions: the interposition of increasing ceramic thicknesses significantly reduced the irradiance and microhardness of resin cement. Increased depth in the resin cement showed significantly reduced microhardness for all studied groups. Increased ceramic opacity reduced the KHN of the resin cement at both depths for all ceramic thicknesses and shades.
Collapse
Affiliation(s)
- Lincoln Pires Silva Borges
- Department of Restorative Dentistry, Dental Materials Division, Piracicaba Dental School, State University of Campinas - UNICAMP, Piracicaba, SP, Brazil
| | - Gilberto Antônio Borges
- Department of Dental Materials and Restorative Dentistry, University of Uberaba, Uberaba, MG, Brazil
| | - Américo Bortolazzo Correr
- Department of Restorative Dentistry, Dental Materials Division, Piracicaba Dental School, State University of Campinas - UNICAMP, Piracicaba, SP, Brazil
| | - Jeffrey A Platt
- Associate Professor of Dental Materials, Indiana University School of Dentistry, Indianapolis, IN, USA
| | - Sidney Kina
- Associate Professor, Kina Essential Balance Institute, Maringá, PR, Brazil
| | - Lourenço Correr-Sobrinho
- Department of Restorative Dentistry, Dental Materials Division, Piracicaba Dental School, State University of Campinas - UNICAMP, Piracicaba, SP, Brazil
| | - Ana Rosa Costa
- Department of Restorative Dentistry, Dental Materials Division, Piracicaba Dental School, State University of Campinas - UNICAMP, Piracicaba, SP, Brazil.
| |
Collapse
|
5
|
Ansarifard E, Panbehzan Z, Giti R. Evaluation of microhardness and water sorption/solubility of dual-cure resin cement through monolithic zirconia in different shades. J Indian Prosthodont Soc 2021; 21:50-56. [PMID: 33835068 PMCID: PMC8061437 DOI: 10.4103/jips.jips_284_20] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Aim: The objective is to evaluate the effect of shades of monolithic zirconia on the microhardness and sorption/solubility of the underlying two dual-cured resin types of cement. Materials and Methods: Eighty samples of two dual-cured resin cement discs were polymerized under 60 monolithic zirconia discs in three shades and directly activated resin discs of cement were used as the control group (n = 10). After 24 h storage at 37°C in an incubator, Vickers microhardness and the sorption and solubility were measured. Statistical Analysis Used: Two-way ANOVA , one-way ANOVA, Independent t-test, Tukey's honestly significant difference, and Tamhane's T2 tests. Results: The mean microhardness of the Variolink N resin cements were significantly higher than Panavia SA ones (P < 0.001). Furthermore, Variolink N cements exhibited lower sorption/solubility than Panavia SA resin cements (both P < 0.05). The ceramic shade had a significant influence on the microhardness of both cements (P < 0.001) but had no significant effect on the sorption/solubility of resin cements (P > 0.05). Conclusion: Interposition of monolithic zirconia decreases the microhardness of resin cement especially Panavia SA. In Variolink N, by increasing the chroma saturation of ceramics, the microhardness decreased, however in Panavia SA, it was altered by the shades, but not in a specific pattern. For both cements, there were no statistical differences between the sorption/solubility of samples photo-cured under different shades. There was a reverse correlation between microhardness and water sorption/solubility of both cements.
Collapse
Affiliation(s)
- Elham Ansarifard
- Department of Prosthodontics, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Zahra Panbehzan
- Department of Prosthodontics, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Rashin Giti
- Department of Prosthodontics, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran
| |
Collapse
|
6
|
Bragança GF, Vianna AS, Neves FD, Price RB, Soares CJ. Effect of exposure time and moving the curing light on the degree of conversion and Knoop microhardness of light-cured resin cements. Dent Mater 2020; 36:e340-e351. [PMID: 32950244 DOI: 10.1016/j.dental.2020.08.016] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2020] [Revised: 07/07/2020] [Accepted: 08/29/2020] [Indexed: 10/23/2022]
Abstract
OBJECTIVE To evaluate the effect of exposure time and moving the light-curing unit (LCU) on the degree of conversion (DC) and Knoop microhardness (KH) of two resin cements that were light-cured through ceramic. METHODS Two resin cements: AllCem Veneer APS (FGM) and Variolink Esthetic LC (Ivoclar Vivadent) were placed into a 0.3 mm thick matrix in 6 locations representing the canine to canine. The resins were covered with 0.5 mm thick lithium disilicate glass-ceramic (IPS e.max CAD, Ivoclar Vivadent). A motorized device moved the LCUs over the ceramic when the LCU was on. Two single-peak LCUs: Elipar DeepCure-L (3M Oral Care) and Emitter C (Schuster), and one multi-peak: Bluephase G2 (Ivoclar Vivadent) were used with 3 different exposure protocols: a localized exposure centered over each tooth for 10 or 40 s; moving the tip across the 6 teeth for a total exposure time of 10 or 40 s; and moving the tip across the 6 teeth resins for a total exposure time of 60 or 240 s. After 24 h, the DC and KH were measured on the top surfaces and the data was analyzed using three-way ANOVA and Tukey's tests (α = 0.05). RESULTS Interposition of 0.5 mm of ceramic reduced the irradiance received by the resin by approximately 50%. The 40 s localized exposure over each tooth always produced significantly higher DC and KH values. Moving the LCUs with a total exposure time of 10 s resulted in the lowest DC and KH. There was no beneficial effect on the DC or KH when the multi-peak (violet-blue) LCU (Elipar DeepCure-L or Bluephase G2), but the lower light output from a small tip LCU reduced the DC and KH values (Emitter C). SIGNIFICANCE Moving the LCUs when photo-curing light-cured resin cements is not recommended. This study showed that a single-peak LCU could activate a resin cement that uses Ivocerin™ as well as the multi-peak LCU.
Collapse
Affiliation(s)
- Gabriel Felipe Bragança
- Biomechanical, Biomaterials and Cell Biology Research Center, Department of Operative Dentistry and Dental Materials, School of Dentistry, Federal University of Uberlândia, Uberlândia, Minas Gerais, Brazil.
| | - Arthur Silva Vianna
- School of Dentistry, Federal University of Uberlândia, Uberlândia, Minas Gerais, Brazil.
| | - Flávio Domingues Neves
- Department of Dental Clinical Sciences, Dalhousie University, Halifax, Nova Scotia, Canada.
| | - Richard Bengt Price
- Department of Occlusion and Prosthodontic, School of Dentistry, Federal University of Uberlândia, Uberlândia, Minas Gerais, Brazil.
| | - Carlos José Soares
- Biomechanical, Biomaterials and Cell Biology Research Center, Department of Operative Dentistry and Dental Materials, School of Dentistry, Federal University of Uberlândia, Uberlândia, Minas Gerais, Brazil.
| |
Collapse
|
7
|
Zago RR, Swarowsky LA, Teixeira GS, Marquezan M, Susin AH, Durand LB. Marginal staining of ultra-thin ceramic veneers. BRAZILIAN JOURNAL OF ORAL SCIENCES 2020. [DOI: 10.20396/bjos.v19i0.8658518] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
Abstract
The pigmentation of the resin cement at the tooth/ceramic interface compromises the esthetic and longevity of ultra-thin ceramic veneers. Aim: The aim of this study was to evaluate marginal staining of ultra-thin ceramic veneers cemented to intact enamel (non-prepared) and prepared enamel. Methods: Thirty-two (32) permanent central incisors were selected and randomly divided into two groups: intact enamel (IE) and prepared enamel (PE). The ceramic veneers of PE group were bonded to the prepared enamel and the ceramic veneers of IE group were cemented directly onto the intact enamel, with no preparation. Both preparation and cementation were standardized and performed by a single operator. Each group was subdivided into two subgroups (n = 8) with different immersion media - coffee and water. After an immersion period of 10 days, stereomicroscope images were made at 20X magnification of the mesial, distal, cervical and incisal surface of each specimen. Three blinded, trained and calibrated examiners evaluated the images of the resin cement interface of each surface. The data were subjected to Kruskal‑Wallis and Mann‑Whitney statistical analysis. Immersion media and enamel preparation influenced the marginal staining of the tooth/ceramic interface. Results: When immersed in coffee, prepared interfaces presented greater marginal staining than unprepared interfaces. When immersed in water, there was no statistically significant difference between the groups. Conclusion: The cementation of ultra-thin ceramic veneers onto intact enamel is associated with less marginal staining and, consequently, improved esthetics.
Collapse
|
8
|
Naliani S, Elias S, Tjandrawinata R. Effect of light intensity, light-curing unit exposure time, and porcelain thickness of ips e.max press and vintage LD press on the hardness of resin cement. SCIENTIFIC DENTAL JOURNAL 2020. [DOI: 10.4103/sdj.sdj_45_19] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|
9
|
Jafari Z, Alaghehmand H, Samani Y, Mahdian M, Khafri S. Light transmittance of CAD/CAM ceramics with different shades and thicknesses and microhardness of the underlying light-cured resin cement. Restor Dent Endod 2018; 43:e27. [PMID: 30135846 PMCID: PMC6103544 DOI: 10.5395/rde.2018.43.e27] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2017] [Accepted: 05/01/2018] [Indexed: 11/11/2022] Open
Abstract
Objectives The aim of this in vitro study was to evaluate the effects of the thickness and shade of 3 types of computer-aided design/computer-aided manufacturing (CAD/CAM) materials. Materials and Methods A total of 120 specimens of 2 shades (A1 and A3) and 2 thicknesses (1 and 2 mm) were fabricated using VITA Mark II (VM; VITA Zahnfabrik), IPS e.max CAD (IE; IvoclarVivadent), and VITA Suprinity (VS; VITA Zahnfabrik) (n = 10 per subgroup). The amount of light transmission through the ceramic specimens was measured by a radiometer (Optilux, Kerr). Light-cured resin cement samples (Choice 2, Bisco) were fabricated in a Teflon mold and activated through the various ceramics with different shades and thicknesses using an LED unit (Bluephase, IvoclarVivadent). In the control group, the resin cement sample was directly light-cured without any ceramic. Vickers microhardness indentations were made on the resin surfaces (KoopaPazhoohesh) after 24 hours of dark storage in a 37°C incubator. Data were analyzed using analysis of variance followed by the Tukey post hoc test (α = 0.05). Results Ceramic thickness and shade had significant effects on light transmission and the microhardness of all specimens (p < 0.05). The mean values of light transmittance and microhardness of the resin cement in the VM group were significantly higher than those observed in the IE and VS groups. The lowest microhardness was observed in the VS group, due to the lowest level of light transmission (p < 0.05). Conclusion Greater thickness and darker shades of the 3 types of CAD/CAM ceramics significantly decreased the microhardness of the underlying resin cement.
Collapse
Affiliation(s)
- Zahra Jafari
- Department of Restorative Dentistry, Dental Faculty, Mazandaran University of Medical Sciences, Sari, Iran
| | - Homayoon Alaghehmand
- Dental Materials Research Center, Institute of Health, Babol University of Medical Sciences, Babol, Iran
| | - Yasaman Samani
- Department of Restorative Dentistry, Dental Faculty, Semnan University of Medical Sciences, Semnan, Iran
| | - Mina Mahdian
- Department of Prosthodontics and Digital Technology, Stony Brook University School of Dental Medicine, Stony Brook, NY, USA
| | - Soraya Khafri
- Department of Biostatistics and Epidemiology, Faculty of Medicine, Babol University of Medical Sciences, Babol, Iran
| |
Collapse
|
10
|
AlShaafi MM. Factors affecting polymerization of resin-based composites: A literature review. Saudi Dent J 2017; 29:48-58. [PMID: 28490843 PMCID: PMC5411902 DOI: 10.1016/j.sdentj.2017.01.002] [Citation(s) in RCA: 53] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2016] [Revised: 01/28/2017] [Accepted: 01/29/2017] [Indexed: 11/15/2022] Open
Abstract
AIM The aim of this review was to help clinicians improve their understanding of the polymerization process for resin-based composites (RBC), the effects of different factors on the process and the way in which, when controlled, the process leads to adequately cured RBC restorations. METHODS Ten factors and their possible effects on RBC polymerization are reviewed and discussed, with some recommendations to improve that process. These factors include RBC shades, their light curing duration, increment thickness, light unit system used, cavity diameter, cavity location, light curing tip distance from the curing RBC surface, substrate through which the light is cured, filler type, and resin/oral cavity temperature. CONCLUSION The results of the review will guide clinicians toward the best means of providing their patients with successfully cured RBC restorations.
Collapse
Affiliation(s)
- Maan M AlShaafi
- Department of Restorative Dental Sciences, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| |
Collapse
|
11
|
Bansal R, Taneja S, Kumari M. Effect of ceramic type, thickness, and time of irradiation on degree of polymerization of dual - cure resin cement. J Conserv Dent 2016; 19:414-8. [PMID: 27656058 PMCID: PMC5026099 DOI: 10.4103/0972-0707.190010] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
Aim: The aim of the study is to evaluate the effect of ceramic type, thickness, and time of irradiation on degree of polymerization of dual-cure resin cement. Materials and Methods: Dual-cure resin cement (SoloCem) was used to prepare disk-shaped samples (0.5 mm thick × 5 mm diameter). Study group samples (n = 5) were light-cured for 40, 60, and 80 s through all ceramic leucite-reinforced (Cergo Kiss), lithium disilicate-reinforced (IPS e.max), and monolithic zirconia-reinforced (Ziecon) of three thicknesses (2, 3, and 4 mm). Negative control group samples were cured through metal disks and positive control samples were cured without the presence of ceramic. The degree of conversion (DC) was evaluated by Fourier transform infrared spectrometer. The recorded data were subjected to one-way analysis of variance, followed by post hoc analysis (Tukey HSD). Results and Conclusion: Greatest light transmission and DC were seen through Cergo Kiss, followed by IPS e.max Press and Ziecon, with insignificant difference between the latter two. The attenuation of light irradiance increased with increasing thickness of ceramic disks, with statistically significant values between 3 and 4 mm. Increasing time of irradiation to cure dual-cure resin cement did not always result in greater degree of polymerization.
Collapse
Affiliation(s)
- Rashi Bansal
- Department of Conservative Dentistry and Endodontics, I.T.S Centre for Dental Studies and Research, Ghaziabad, Uttar Pradesh, India
| | - Sonali Taneja
- Department of Conservative Dentistry and Endodontics, I.T.S Centre for Dental Studies and Research, Ghaziabad, Uttar Pradesh, India
| | - Manju Kumari
- Department of Conservative Dentistry and Endodontics, I.T.S Centre for Dental Studies and Research, Ghaziabad, Uttar Pradesh, India
| |
Collapse
|
12
|
Çömlekoğlu ME, Paken G, Tan F, Dündar-Çömlekoğlu M, Özcan M, Akan E, Aladağ A. Evaluation of Different Thickness, Die Color, and Resin Cement Shade for Veneers of Multilayered CAD/CAM Blocks. J Prosthodont 2015; 25:563-569. [DOI: 10.1111/jopr.12367] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/25/2015] [Indexed: 11/27/2022] Open
Affiliation(s)
| | - Gamze Paken
- Department of Prosthodontics, School of Dentistry; Ege University; Izmir Turkey
| | - Firuzan Tan
- Department of Prosthodontics, School of Dentistry; Ege University; Izmir Turkey
| | | | - Mutlu Özcan
- University of Zürich, Dental Materials Unit, Center for Dental and Oral Medicine; Clinic for Fixed and Removable Prosthodontics and Dental Materials Science; Zürich Switzerland
| | - Ender Akan
- Department of Prosthodontics, School of Dentistry; İzmir Katip Çelebi University; Izmir Turkey
| | - Akın Aladağ
- Department of Prosthodontics, School of Dentistry; Ege University; Izmir Turkey
| |
Collapse
|